Volatile organic compounds detected in the atmosphere of NASA's Biomass Production Chamber

Atmospheres of enclosed environments in which 20 m2 stands of wheat, potato, and lettuce were grown were characterized and quantified by gas chromatography-mass spectrometry. A large number (in excess of 90) of volatile organic compounds (VOCs) were identified in the chambers. Twenty eight VOC's were assumed to be of biogenic origin for these were not found in the chamber atmosphere when air samples were analyzed in the absence of plants. Some of the compounds found were unique to a single crop. For example, only 35% of the biogenic compounds detected in the wheat atmosphere were unique to wheat, while 36% were unique to potato and 26% were unique to lettuce. The number of compounds detected in the wheat (20 compounds) atmosphere was greater than that of potato (11) and lettuce (15) and concentration levels of biogenic and non-biogenic VOC's were similar.

NASA Discipline Number 61-20↗

Potassium permanganate for mercury vapor environmental control

Potassium permanganate (KMnO4) was evaluated for application in removing mercury vapor from exhaust air systems. The KMnO4 may be used in water solution with a liquid spray scrubber system or as a solid adsorber bed material when impregnated onto a zeolite. Air samples contaminated with as much as 112 mg/cu m of mercury were scrubbed to 0.06mg/cum with the KMnO4-impregnated zeolite (molecular sieve material). The water spray solution of permanganate was also found to be as effective as the impregnated zeolite. The KMnO4-impregnated zeolite was applied as a solid adsorber material to (1) a hardware decontamination system, (2) a model incinerator, and (3) a high vacuum chamber for ion engine testing with mercury as the propellant. A liquid scrubber system was also applied in an incinerator system. Based on the results of these experiments, it is concluded that the use of KMnO4 can be an effective method for controlling noxious mercury vapor.

Kuivinen, D. E.↗

Mass spectrometry and inhomogeneous ion optics

Work done in several areas to advance the state of the art of magnetic mass spectrometers is described. The calculations and data necessary for the design of inhomogeneous field mass spectrometers, and the calculation of ion trajectories through such fields are presented. The development and testing of solid state ion detection devices providing the capability of counting single ions is discussed. New techniques in the preparation and operation of thermal-ionization ion sources are described. Data obtained on the concentrations of copper in rainfall and uranium in air samples using the improved thermal ionization techniques are presented. The design of a closed system static mass spectrometer for isotopic analyses is discussed. A summary of instrumental aspects of a four-stage mass spectrometer comprising two electrostatic and two 90 deg. magnetic lenses with a 122-cm radius used to study the interaction of ions with solids is presented.

White, F. A.↗

Flight test of a pressurization system used to measure minor atmospheric constituents from an aircraft

A flight evaluation of an ambient air sample pressurization system was conducted at altitudes between 6 and 12 km. The system regulated the sample pressure to 10.15 + or - 0.1 N/sq n and provided sample flow to three gas analysis instruments included in the system. Ozone concentrations measured by two instruments employing different techniques varied from about 30 parts per billion by volume (ppbv) to over 350 ppbv, and the two ozone monitors agreed to within 20 ppbv. A carbon dioxide analyzer indicated modifications required for future installations.

Reck, G. M.↗

Aerodynamic size distribution of suspended particulate matter in the ambient air in the city of Cleveland, Ohio

The City of Cleveland Division of Air Pollution Control and NASA jointly investigated the chemical and physical characteristics of the suspended particulate matter in Cleveland, and as part of the program, measurements of the particle size distribution of ambient air samples at five urban locations during August and September 1972 were made using high-volume cascade impactions. The distributions were evaluated for lognormality, and the mass median diameters were compared between locations and as a function of resultant wind direction. Junge-type distributions were consistent with dirty continental aerosols. About two-thirds of the suspended particulate matter observed in Cleveland is less than 7 microns in diameter.

Leibecki, H. F.↗

Upper atmosphere pollution measurements (GASP)

The environmental effects are discussed of engine effluents of future large fleets of aircraft operating in the stratosphere. Topics discussed include: atmospheric properties, aircraft engine effluents, upper atmospheric measurements, global air sampling, and data reduction and analysis

Rudey, R. A.↗

Development and testing of a portable wind sensitive directional air sampler

A portable wind-sensitive directional air sampler has been developed as part of an air pollution source identification system. The system is designed to identify sources of air pollution based on the directional collection of field air samples and their analysis for TSP and trace element characteristics. Sources can be identified by analyzing the data on the basis of pattern recognition concepts. Functional testing of a prototype sampler is described; all items exhibited performance and life sufficient to carry out field performance test operations. Life testing of the wind direction sensor and the directional porting valves, which are critical to reliable operation, was emphasized with successful results.

Deyo, J.↗

Concentrations of CH4, CO, CO2, H2, H2O and N2O in the upper stratosphere

On 23 May 1973 a cryogenic air sampler was flown on an Aerobee rocket from White Sands Missile Range. A large air sample was collected between 40 and 50 km altitude and successfully recovered for water vapor and trace gas analysis. The results were as follows: water vapor, 4.0 (+1.3 or - 0.9) ppmV; methane, 0.37 + or - 0.01 ppmV; molecular hydrogen, 0.47 + or - 0.02 ppmV; carbon monoxide, 0.05 + or - 0.01 ppmV; carbon dioxide, 316.2 + or - 2.8 ppmV; and nitrous oxide, 3 + or - 7 ppb.

Ehhalt, D. H.↗

Space Shuttle Trace Gas Analyzer

A Trace Gas Analyzer (TGA) with the ability to detect the presence of toxic contaminants in the Space Shuttle atmosphere within the subparts-per-million range is under development. The design is a modification of the miniaturized Gas Chromatograph-Mass Spectrometer (GCMS) developed for the Viking Mars Lander. An ambient air sample is injected onto the GC column from a constant volume sample loop and separated into individual compounds for identification by the MS. The GC-MS interface consists of an effluent divider and a silver-paladium separator, an electrochemical cell which removes more than 99.99% of the hydrogen carrier gas. The hydrogen is reclaimed and repressurized without affecting the separator efficiency, a feature which enables a considerable weight reduction in the carrier gas supply system.

Dencker, W.↗

Measurements of atmospheric ozone made from a GASP-equipped 747 airliner Mid-March, 1975

This paper presents data on the ozone mixing ratio, static air temperature, wind speed, and wind direction obtained at altitudes from 8 to 12 km during several flights of a commercial airliner equipped with a fully automated air-sampling system developed for the NASA Global Atmospheric Sampling Program (GASP). The objectives of GASP are reviewed, and the data-gathering techniques are described. Two data sets are discussed which illustrate variations of the upper-tropospheric and lower-stratospheric ozone mixing ratios as a function of geographical location and aircraft altitude. Good agreement is found between the GASP data and the tropopause height obtained from National Meteorological Center gridded data.

Falconer, P. D.↗

Status of NASA aircraft engine emission reduction and upper atmosphere measurement programs

Advanced emission reduction techniques for five existing aircraft gas turbine engines are evaluated. Progress made toward meeting the 1979 EPA standards in rig tests of combustors for the five engines is reported. Results of fundamental combustion studies suggest the possibility of a new generation of jet engine combustor technology that would reduce oxides-of-nitrogen (NOx) emissions far below levels currently demonstrated in the engine-related programs. The Global Air Sampling Program (GAS) is now in full operation and is providing data on constituent measurements of ozone and other minor upper-atmosphere species related to aircraft emissions.

Rudey, R. A.↗

Ion chromatographic determination of anions collected on filters at altitudes between 9.6 and 13.7 kilometers

The investigation of atmospheric pollution to determine the anion-containing particulates in the atmosphere at altitudes between 9.6 and 13.7 km is discussed. Air samples collected on cellulose fiber discs impregnated with dibutoxyethylphthalate require very sensitive methods of analysis. It is concluded that ion chromatography is suited for the determination of anions collected on the filters. Methods to control contamination and interfering side reactions are described.

Otterson, D. A.↗

Evaluation of a hydrogen chloride detector for environmental monitoring

The paper describes a hydrogen chloride detector designed to monitor concentrations of hydrogen chloride gas in the ambient environment. The detector was developed for NASA for use in launch vehicle effluent monitoring. The detector operates on chemiluminescence principles with a lower detection limit of less than 5 x 10 to the -3rd ppm (by volume). The hydrogen chloride in the air sample reacts with a bromide-bromate coating in the inlet tube of the instrument producing bromine. Bromine is then quantitated by chemiluminescent oxidation of luminol. The visible light generated in the chemiluminescent reaction is proportional to the hydrogen chloride concentration of the sampled airstream. The detector is most suited to laboratory or field studies where hydrogen chloride is the dominant pollutant, as compared to the interfering species. Interferences include strong acids, acid-forming gases, and halogen gases. Of the interferences investigated the most serious in these groups are hydrochloric and sulfuric acid, sulfur dioxide, and chlorine, respectively. The detector has been in use since 1974 and has been found to be highly portable, rugged, and stable under extreme environmental conditions.

Gregory, G. L.↗

High-flying Mini-Sniffer RPV - Mars bound

The Mini-Sniffer is a small unmanned survey aircraft developed by NASA to conduct turbulence and atmospheric pollution measurements from ground level to an altitude of 90,000 ft. Carrying a 25-lb air sampling apparatus, the Mini-Sniffer typically cruises for one hour at 70,000 ft before being remotely piloted back to earth. A hydrazine monopropellant engine powers the craft, while a PCM telemetering system and a radar transponder provide control functions. Development of a high-performance low-Reynolds-number airfoil could make the research craft suitable for a low-altitude terrain-following mission on Mars.

Reed, R. D.↗

Recommendations of the panels: Panel on in-flight measurements

The attenuation factor for aircraft other than the B-747 in reducing the ambient ozone concentrations which enter the cabin is obtained. The need to continue NASA Global Air Sampling Program measurements was expressed for three main purposes; testing new filters, correlation of complaints with ozone levels, and ambient ozone data. The need to continue cooperation between NASA and industry is indicated. Concern with regard to the correlation of ozone levels and complaints was given. The need to measure the variability of ozone within the aircraft cabin was investigated. The requirement for an onboard ozone monitor on all aircraft is discussed.

Rogers, J.↗

Measurement of NO and O3 from aircraft: 1977 tropical convergence zone experiment

As part of the Ames Research Center program to explore the nature of stratosphere-troposphere exchange processes occurring in the Intertropical Convergence Zone, simultaneous in situ measurements of nitric oxide and ozone mixing ratios were made with the Ames stratospheric air sampler SAS 2. The SAS 2 is a second-generation system; it employs four parallel sensors and was designed primarily for measurements at altitudes of 60,000 ft and above on the U-2 stratospheric research aircraft. The only modifications required for this study was the addition of an air sample flow restrictor. Data were obtained with the SAS 2 system on July 26, 27, 30 and 31, 1977. Generally, 30-min measurements were made at each of six altitudes ranging from 45,000 ft to 70,000 ft, and separated by 5,000 ft intervals.

Starr, W. L.↗