Search NASA⌕ Search

SEARCH · Search NASA

Results for “BEAM OPTICS”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 163 records · Page 9

The energy dependence and dose response of a commercial optically stimulated luminescent detector for kilovoltage photon, megavoltage photon, and electron, proton, and carbon beams

Optically stimulated luminescent detectors, which are widely used in radiation protection, offer a number of potential advantages for application in radiation therapy dosimetry. Their introduction into this field has been somewhat hampered by the lack of information on their radiation response in megavoltage beams. Here the response of a commercially available optically stimulated luminescent detector (OSLD) is determined as a function of energy, absorbed dose to water, and linear energy transfer (LET). The detector response was measured as a function of energy for absorbed doses from 0.5 to 4.0 Gy over the following ranges: 125 kVp to18 MV for photons, 6-20 MeV for electrons, 50-250 MeV for protons, and 290 MeV/u for the carbon ions. For the low LET beams, the response of the detector was linear up to 2 Gy with supralinearity occurring at higher absorbed doses. For the kilovoltage photons, the detector response relative to 6 MV increased with decreasing energy due to the higher atomic number of aluminum oxide (11.2) relative to water (7.4). For the megavoltage photons and electrons, the response was independent of energy. The response for protons was also independent of energy, but it was about 6% higher than its response to 6 MV photons. For the carbon ions, the dose response was linear for a given LET from 0.5 to 4.0 Gy, and no supralinearity was observed. However, it did exhibit LET dependence on the response relative to 6 MV photons decreasing from 1.02 at 1.3 keV/{mu}m to 0.41 at 78 keV/{mu}m. These results provide additional information on the dosimetric properties for this particular OSL detector and also demonstrate the potential for their use in photon, electron, and proton radiotherapy dosimetry with a more limited use in high LET radiotherapy dosimetry.

61 RADIATION PROTECTION AND DOSIMETRY↗

Crossed beam roof target for motion tracking

A system for detecting motion between a first body and a second body includes first and second detector-emitter pairs, disposed on the first body, and configured to transmit and receive first and second optical beams, respectively. At least a first optical rotator is disposed on the second body and configured to receive and reflect at least one of the first and second optical beams. First and second detectors of the detector-emitter pairs are configured to detect the first and second optical beams, respectively. Each of the first and second detectors is configured to detect motion between the first and second bodies in multiple degrees of freedom (DOFs). The first optical rotator includes a V-notch oriented to form an apex of an isosceles triangle with respect to a base of the isosceles triangle formed by the first and second detector-emitter pairs. The V-notch is configured to receive the first optical beam and reflect the first optical beam to both the first and second detectors. The V-notch is also configured to receive the second optical beam and reflect the second optical beam to both the first and second detectors.

Olczak, Eugene↗

Enhanced optical limiting effects in a double-decker bis(phthalocyaninato) rare earth complex using radially polarized beams

Optical limiting (OL) effects can be enhanced by exploiting various limiting mechanisms and by designing nonlinear optical materials. In this work, we present the large enhancement of OL effects by manipulating the polarization distribution of the light field. Theoretically, we develop the Z-scan and nonlinear transmission theories on a two-photon absorber under the excitation of cylindrical vector beams. It is shown that both the sensitivity of Z-scan technique and the OL effect using radially polarized beams have the large enhancement compared with that using linearly polarized beams (LPBs). Experimentally, we investigate the nonlinear absorption properties of a double-decker Pr[Pc(OC{sub 8}H{sub 17}){sub 8}]{sub 2} rare earth complex by performing Z-scan measurements with femtosecond-pulsed radially polarized beams at 800 nm wavelength. The observed two-photon absorption process, which originates from strong intramolecular π–π interaction, is exploited for OL application. The results demonstrate the large enhancement of OL effects using radially polarized beams instead of LPBs.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Study of an Integration Platform Based on an Adiabatic Active-Layer Waveguide Connection for InP Photonic Device Integration Mirroring That of Heterogeneous Integration on Silicon

In this work, a photonic device integration platform capable of integration of active-passive InP-based photonic devices without the use of material regrowth is introduced. The platform makes use of an adiabatic active-layer waveguide connection (ALWC) to move an optical beam between active and passive devices. The performance of this platform is analyzed using an example made up of four main sections: (1) a fiber coupling section for enabling vertical beam coupling from optical fiber into the photonic chip using a mode-matched surface grating with apodized duty cycles; (2) a transparent waveguide section for realizing passive photonic devices; (3) an adiabatic mode connection structure for moving the optical beam between passive and active device sections; and (4) an active device section for realizing active photonic devices. It is shown that the coupled surface grating, when added with a bottom gold reflector, can achieve a high chip-to-fiber coupling efficiency (CE) of 88.3% at 1550 nm. The adiabatic active-layer mode connection structure has an optical loss of lower than 1% (CE > 99%). The active device section can achieve an optical gain of 20 dB/mm with the use of only 3 quantum wells. The optimized structural parameters of the entire waveguide module are analyzed and discussed.

42 ENGINEERING↗

Truncated non-linear interferometer-based sensor system

A truncated non-linear interferometer-based sensor system includes an input that receives an optical beam and a non-linear amplifier that generates a probe beam and a conjugate beam from the optical beam. The system's local oscillators are related to the probe beam and the conjugate beam. The system includes a sensor that transduces an input with the probe beam and the conjugate beam. The transduction detects changes in the phase of each of the probe beam and the conjugate beam. The system's phase sensitive detectors detect phase modulations between the respective local oscillators, the probe beam, and the conjugate beam and outputs phase signals based on detected phase modulations. The system measures phase signals indicative of the sensor's input resulting from a sum or difference of the phase signals. The measurement exhibits a quantum noise reduction in an intensity difference, a phase sum, or an amplitude difference quadrature.

47 OTHER INSTRUMENTATION↗

Dual wavelength negative imaging DLP-SLA system and method

The present disclosure relates to a method for forming a three dimensional (3D) component from a photopolymer resin. The method may involve generating a first optical beam at a first wavelength, with the first optical beam causing polymerization of a photopolymerizable resist. A second optical beam is generated at a second wavelength, different from the first wavelength, which inhibits polymerization of the photopolymerizable resist. A device is used to receive the first and second optical beams and to generate therefrom corresponding separate first and second light patterns, respectively, where the first light pattern forms a first image on the photopolymerizable resist to cause polymerization of a first portion of the photopolymerizable resist, while the second light pattern forms a second image on the photopolymerizable resist and inhibits polymerization of a second portion of the photopolymerizable resist.

Moran, Bryan D.↗

Optical cone beam tomography of Cherenkov-mediated signals for fast 3D dosimetry of x-ray photon beams in water

Purpose: To test the use of a three-dimensional (3D) optical cone beam computed tomography reconstruction algorithm, for estimation of the imparted 3D dose distribution from megavoltage photon beams in a water tank for quality assurance, by imaging the induced Cherenkov-excited fluorescence (CEF). Methods: An intensified charge-coupled device coupled to a standard nontelecentric camera lens was used to tomographically acquire two-dimensional (2D) projection images of CEF from a complex multileaf collimator (MLC) shaped 6 MV linear accelerator x-ray photon beam operating at a dose rate of 600 MU/min. The resulting projections were used to reconstruct the 3D CEF light distribution, a potential surrogate of imparted dose, using a Feldkamp–Davis–Kress cone beam back reconstruction algorithm. Finally, the reconstructed light distributions were compared to the expected dose values from one-dimensional diode scans, 2D film measurements, and the 3D distribution generated from the clinical Varian ECLIPSE treatment planning system using a gamma index analysis. A Monte Carlo derived correction was applied to the Cherenkov reconstructions to account for beam hardening artifacts. Results: 3D light volumes were successfully reconstructed over a 400 × 400 × 350 mm{sup 3} volume at a resolution of 1 mm. The Cherenkov reconstructions showed agreement with all comparative methods and were also able to recover both inter- and intra-MLC leaf leakage. Based upon a 3%/3 mm criterion, the experimental Cherenkov light measurements showed an 83%–99% pass fraction depending on the chosen threshold dose. Conclusions: The results from this study demonstrate the use of optical cone beam computed tomography using CEF for the profiling of the imparted dose distribution from large area megavoltage photon beams in water.

07 ISOTOPE AND RADIATION SOURCES↗

Direct femtosecond laser ablation of copper with an optical vortex beam

Laser surface structuring of copper is induced by laser ablation with a femtosecond optical vortex beam generated via spin-to-orbital conversion of the angular momentum of light by using a q-plate. The variation of the produced surface structures is studied as a function of the number of pulses, N, and laser fluence, F. After the first laser pulse (N=1), the irradiated surface presents an annular region characterized by a corrugated morphology made by a rather complex network of nanometer-scale ridges, wrinkles, pores, and cavities. Increasing the number of pulses (2 1000) and a deep crater is formed. The nanostructure variation with the laser fluence, F, also evidences an interesting dependence, with a coarsening of the structure morphology as F increases. Our experimental findings demonstrate that direct femtosecond laser ablation with optical vortex beams produces interesting patterns not achievable by the more standard beams with a Gaussian intensity profile. They also suggest that appropriate tuning of the experimental conditions (F, N) can allow generating micro- and/or nano-structured surface for any specific application.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Design and characterization of electron beam focusing for X-ray generation in novel medical imaging architecture

A novel electron beam focusing scheme for medical X-ray sources is described in this paper. Most vacuum based medical X-ray sources today employ a tungsten filament operated in temperature limited regime, with electrostatic focusing tabs for limited range beam optics. This paper presents the electron beam optics designed for the first distributed X-ray source in the world for Computed Tomography (CT) applications. This distributed source includes 32 electron beamlets in a common vacuum chamber, with 32 circular dispenser cathodes operated in space charge limited regime, where the initial circular beam is transformed into an elliptical beam before being collected at the anode. The electron beam optics designed and validated here are at the heart of the first Inverse Geometry CT system, with potential benefits in terms of improved image quality and dramatic X-ray dose reduction for the patient.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Optical fiber system employing topological guidance of light

An optical fiber system exploits a principle of topological confinement for guided higher-order modes, in contrast to more conventional total-internal-reflection (TIR) confinement. The optical fiber has a geometry and index profile defining a cutoff wavelength for a predetermined L-mode of optical signal propagation in the optical fiber, where L is azimuthal mode index. An optical source subsystem is coupled to the optical fiber to establish an optical signal propagating in the optical fiber, wherein the optical signal has the predetermined L-mode and a wavelength being either (1) at least 15% above the cutoff wavelength such that the optical beam propagates as a topologically confined mode, or (2) sufficiently above the cutoff wavelength that, based on the L-mode of the optical beam, the optical beam propagates as a topologically confined mode having propagation loss less than 3 dB/meter.

Ramachandran, Siddharth↗

Acousto-optic modulators for a controlled frequency shift of light beams in optical and microwave cold-atom frequency standards

A series of specialised acousto-optic modulators/frequency shifters based on paratellurite (TeO{sub 2}) single crystals is developed for systems of laser cooling and frequency stabilisation of laser sources in optical and microwave frequency standards based on cold strontium, rubidium and caesium atoms. The methods of calculation and optimisation of the main parameters of acousto-optic modulators are considered; their basic technical characteristics are experimentally investigated in the spectral range of optical radiation 460 – 900 nm and in the frequency shift range of 5 – 400 MHz. The modulators have a high diffraction efficiency, low power consumption and the ability to work with linearly and randomly polarised optical radiation. (frequency standards)

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Ultrafast photonic micro-systems

A microelectromechanical device for diffracting optical beams comprises a diffractive element suspended over a channel. The diffractive element is configured to receive an optical beam and diffract and/or transmit the optical beam based on an orientation of the diffractive element. At least one torsional actuator is operatively connected to the diffractive element. The at least one torsional actuator is configured to selectively adjust the orientation of the diffractive element. The diffractive element has a diffractive element resonant frequency that is nearly the same as a resonant frequency of the optical beam.

Wang, Jin↗

Dew point meter, components thereof, and methods of use thereof

In one aspect, the present disclosure is directed to a sample cell for a dew point meter, the sample cell comprising: a flow channel configured to receive a gas sample, the flow channel comprising: a non-mirror window surface, wherein the flow channel is configured to allow a first optical beam originating from an optical source to impinge on the non-mirror window surface and output a second optical beam from the non-mirror window surface towards an optical detector.

Cheng, Mao↗

Analysis of the effect of spherical aberrations on a solenoid scan

Solenoid scans are often used to determine the beam emittance of an intense relativistic electron beam (IREB). In a solenoid scan, the beam size is measured at a location downstream of the solenoid as a function of the strength of the solenoid magnetic field. The emittance is then inferred using a beam optics model of the transport of the beam through the solenoid magnet to the imaging location. This requires precise knowledge of the field strength and shape as a function of the current supplied to the solenoid. The beam optics model for an IREB needs to include an accurate model of the magnetic field. Unfortunately, most beam optics models do not include the effect of spherical aberrations which are inherent in a solenoid magnet. Spherical aberrations are manifested as an essentially quadratic increase in the solenoid magnetic field as a function of radius. One consequence of this is that the focal length will be dependent on the beam radius. This note examines the sensitivity of a typical solenoid scan performed on DARHT axis 2 to spherical aberrations. The sensitivity to spherical aberrations is examined as a function of the beam envelope size and the drift distance from the solenoid magnet to the imaging station.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Femtosecond laser surface structuring of silicon using optical vortex beams generated by a q-plate

We report on laser surface structuring of silicon using Ti:Sa femtosecond laser ablation with optical vortex beams. A q-plate is used to generate an optical vortex beam with femtosecond pulse duration through spin-to-orbital conversion of the angular momentum of light. The variation of the produced surface structures is investigated as a function of the number of pulses, N, at laser fluence slightly above the ablation threshold value. At low N (≈10), only surface corrugation of the irradiated, ring-shaped area is observed. This is followed by a progressive formation of regular ripples at larger N (≈100–500), which eventually transform in smaller columnar structures for N ≈ 1000. Moreover, the central, non-ablated part is gradually decorated by nanoparticles produced during laser ablation, a process which eventually leads to the formation of a central turret of assembled nanoparticles. Our experimental findings suggest the importance of a feedback mechanism and a cumulative effect on the formation of ripples with interesting patterns not achievable by the more standard beams with a Gaussian intensity profile.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Optics measurement and correction during acceleration with beta-squeeze in RHIC

In the past, beam optics correction at RHIC has only taken place at injection and at final energy, with interpolation of corrections partially into the acceleration cycle. Recent measurements of the beam optics during acceleration and squeeze have evidenced significant beta-beats that, if corrected, could minimize undesirable emittance dilutions and maximize the spin polarization of polarized proton beams by avoiding the high-order multipole fields sampled by particles within the bunch. We recently demonstrated successful beam optics corrections during acceleration at RHIC. We verified conclusively the superior control of the beam realized via these corrections

43 PARTICLE ACCELERATORS↗