Search NASA⌕ Search

SEARCH · Search NASA

Results for “DIGITAL INTEGRATORS”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 163 records · Page 9

Upper-Bound SEU Rates In Anisotropic Fluxes

Upper bounds on rates of single-event upsets (SEU's) in digital integrated circuits and other electronic devices exposed to anisotropic fluxes of energetic ionizing particles computed by use of improved method. Derived from simplified, worst-case mathematical models of charge-collecting volumes and physical phenomena in electronic devices.

Edmonds, Larry D.↗

Flight testing of a fiber optic temperature sensor

A fiber optic temperature sensor (FOTS) system consisting of an optical probe, a flexible fiber optic cable, and an electro-optic signal processor was fabricated to measure the gas temperature in a turbine engine. The optical probe contained an emissive source embedded in a sapphire lightguide coupled to a fiber-optic jumper cable and was retrofitted into an existing thermocouple probe housing. The flexible fiber optic cable was constructed with 200 micron core, polyimide-coated fiber and was ruggedized for an aircraft environment. The electro-optic signal processing unit was used to ratio the intensities of two wavelength intervals and provided an analog output value of the indicated temperature. Subsequently, this optical sensor system was installed on a NASA Dryden F-15 Highly Integrated Digital Electronic Control (HIDEC) Aircraft Engine and several flight tests were conducted. Over the course of flight testing, the FOTS system's response was proportional to the average of the existing thermocouples sensing the changes in turbine engine thermal conditions.

Finney, M. J.↗

Performance-seeking control - Program overview and future directions

A flight test evaluation of the performance-seeking control (PSC) algorithm on the NASA F-15 highly integrated digital electronic control research aircraft was conducted for single-engine operation at subsonic and supersonic speeds. The model-based PSC system was developed with three optimization modes: minimum fuel flow at constant thrust, minimum turbine temperature at constant thrust, and maximum thrust at maximum dry and full afterburner throttle settings. Subsonic and supersonic flight testing were conducted at the NASA Dryden Flight Research Facility covering the three PSC optimization modes and over the full throttle range. Flight results show substantial benefits. In the maximum thrust mode, thrust increased up to 15 percent at subsonic and 10 percent at supersonic flight conditions. The minimum fan turbine inlet temperature mode reduced temperatures by more than 100 F at high altitudes. The minimum fuel flow mode results decreased fuel consumption up to 2 percent in the subsonic regime and almost 10 percent supersonically. These results demonstrate that PSC technology can benefit the next generation of fighter or transport aircraft.

Gilyard, Glenn B.↗

Performance seeking control: Program overview and future directions

A flight test evaluation of the performance-seeking control (PSC) algorithm on the NASA F-15 highly integrated digital electronic control research aircraft was conducted for single-engine operation at subsonic and supersonic speeds. The model-based PSC system was developed with three optimization modes: minimum fuel flow at constant thrust, minimum turbine temperature at constant thrust, and maximum thrust at maximum dry and full afterburner throttle settings. Subsonic and supersonic flight testing were conducted at the NASA Dryden Flight Research Facility covering the three PSC optimization modes and over the full throttle range. Flight results show substantial benefits. In the maximum thrust mode, thrust increased up to 15 percent at subsonic and 10 percent at supersonic flight conditions. The minimum fan turbine inlet temperature mode reduced temperatures by more than 100 F at high altitudes. The minimum fuel flow mode results decreased fuel consumption up to 2 percent in the subsonic regime and almost 10 percent supersonically. These results demonstrate that PSC technology can benefit the next generation of fighter or transport aircraft. NASA Dryden is developing an adaptive aircraft performance technology system that is measurement based and uses feedback to ensure optimality. This program will address the technical weaknesses identified in the PSC program and will increase performance gains.

Gilyard, Glenn B.↗

F-15 835 (HIDEC) Resource Tape

This video presents raw, unedited material of Dryden's F-15 Highly Integrated Digital Electronic Control (HIDEC) aircraft.

Source record↗

F-15 Propulsion Controlled Aircraft (PCA)

This video presentation is a news release highlighting the F-15 Highly Integrated Digital Electronic Controls (HIDEC) Propulsion Controlled Aircraft (PCA) software through June 1993 at Dryden.

Source record↗

The MAMMOTH project

On the surface MAMMOTH is a high performance 5.25-inch half-high 8mm helical scan tape drive that records a native 20 Gigabytes of data on Advanced Metal Evaporated media at a sustained throughput of 3 Megabyte per second over a high speed SCSI interface, that is scheduled for production in the second half of 1995. But it's much more than that. Inside its custom designed sheet metal enclosure lies one of the greatest technical achievements of its kind. Exabyte's strategic direction is to increase throughput and capacity while continuing to improve drive, data and media reliability to its products. MAMMOTH adheres to that direction and the description of its technical advances is described in this paper. MAMMOTH can be broken down into four main functional assemblies: high-performance integrated digital electronics, high-reliability tape transport mechanism, high-performance scanner, and advanced metal evaporated media. All this technology is packaged into a standard 5.25-inch half-high form factor that dissipates only 15 watts.

Gerchar, Tim↗

Geostationary Operational Environmental Satellite (GOES)-8 mission flight experience

The Geostationary Operational Environmental Satellite (GOES)-8 spacecraft was launched on April 13, 1994, at 06:04:02 coordinated universal time (UTC), with separation from the Atlas-Centaur launch vehicle occurring at 06:33:05 UTC. The launch was followed by a series of complex, intense operations to maneuver the spacecraft into its geosynchronous mission orbit. The Flight Dynamics Facility (FDF) of the Goddard Space Flight Center (GSFC) Flight Dynamics Division (FDD) was responsible for GOES-8 attitude, orbit maneuver, orbit determination, and station acquisition support during the ascent phase. This paper summarizes the efforts of the FDF support teams and highlights some of the unique challenges the launch team faced during critical GOES-8 mission support. FDF operations experience discussed includes: (1) The abort of apogee maneuver firing-1 (AMF-1), cancellation of AMF-3, and the subsequent replans of the maneuver profile; (2) The unexpectedly large temperature dependence of the digital integrating rate assembly (DIRA) and its effect on GOES-8 attitude targeting in support of perigee raising maneuvers; (3) The significant effect of attitude control thrusting on GOES-8 orbit determination solutions; (4) Adjustment of the trim tab to minimize torque due to solar radiation pressure; and (5) Postlaunch analysis performed to estimate the GOES-8 separation attitude. The paper also discusses some key FDF GOES-8 lessons learned to be considered for the GOES-J launch which is currently scheduled for May 19, 1995.

Noonan, C. H.↗

Flight test validation of a frequency-based system identification method on an F-15 aircraft

A frequency-based performance identification approach was evaluated using flight data from the NASA F-15 Highly Integrated Digital Electronic Control aircraft. The approach used frequency separation to identify the effectiveness of multiple controls simultaneously as an alternative to independent control identification methods. Fourier transformations converted measured control and response data into frequency domain representations. Performance gradients were formed using multiterm frequency matching of control and response frequency domain models. An objective function was generated using these performance gradients. This function was formally optimized to produce a coordinated control trim set. This algorithm was applied to longitudinal acceleration and evaluated using two control effectors: nozzle throat area and inlet first ramp. Three criteria were investigated to validate the approach: simultaneous gradient identification, gradient frequency dependency, and repeatability. This report describes the flight test results. These data demonstrate that the approach can accurately identify performance gradients during simultaneous control excitation independent of excitation frequency.

Schkolnik, Gerard S.↗

Compiled Data On Single-Event Effects Caused By Heavy Ions

Report presents test data on susceptibility of new set of digital integrated circuits and other semiconductor products to single-event effects (soft errors and latchups) caused by heavy ions incident at high energies. Data used to develop generalizations for protecting electronic equipment from single-event effects. In some cases, tested parts selected as candidates for use in specific applications.

Nichols, Donald K.↗

Geostationary Operational Environmental Satellite (GOES) Gyro Temperature Model

The geostationary Operational Environmental Satellite (GOES) 1/M series of spacecraft are geostationary weather satellites that use the latest in weather imaging technology. The inertial reference unit package onboard consists of three gyroscopes measuring angular velocity along each of the spacecraft's body axes. This digital integrating rate assembly (DIRA) is calibrated and used to maintain spacecraft attitude during orbital delta-V maneuvers. During the early orbit support of GOES-8 (April 1994), the gyro drift rate biases exhibited a large dependency on gyro temperature. This complicated the calibration and introduced errors into the attitude during delta-V maneuvers. Following GOES-8, a model of the DIRA temperature and drift rate bias variation was developed for GOES-9 (May 1995). This model was used to project a value of the DIRA bias to use during the orbital delta-V maneuvers based on the bias change observed as the DIRA warmed up during the calibration. The model also optimizes the yaw reorientation necessary to achieve the correct delta-V pointing attitude. As a result, a higher accuracy was achieved on GOES-9 leading to more efficient delta-V maneuvers and a propellant savings. This paper summarizes the: Data observed on GOES-8 and the complications it caused in calibration; DIRA temperature/drift rate model; Application and results of the model on GOES-9 support.

Rowe, J. N.↗

Results from ACTS Development and On-Orbit Operations

The Advanced Communications Technology Satellite (ACTS) was sponsored by NASA to develop the technology for 30/20 Ghz, spot beam communications satellites with on-board baseband and microwave matrix switching. The spot beams allow the use of very small aperture, low cost terminals as well as provide a large degree of frequency reuse. These technologies also significantly reduce the on-orbit weight per unit communication capacity. The ACTS system provides, for the most part, on-demand, integrated digital satellite /terrestrial networks with service data rates from 64 Kbps to 622 Mbps. This paper discusses the results obtained from the ACTS development and its first two years of on-orbit operations for fixed and mobile services.

Gedney, Richard T.↗

Cell Libraries

A NASA contract led to the development of faster and more energy efficient semiconductor materials for digital integrated circuits. Gallium arsenide (GaAs) conducts electrons 4-6 times faster than silicon and uses less power at frequencies above 100-150 megahertz. However, the material is expensive, brittle, fragile and has lacked computer automated engineering tools to solve this problem. Systems & Processes Engineering Corporation (SPEC) developed a series of GaAs cell libraries for cell layout, design rule checking, logic synthesis, placement and routing, simulation and chip assembly. The system is marketed by Compare Design Automation.

Source record↗

Quantification of mitral regurgitation by automated cardiac output measurement: experimental and clinical validation

OBJECTIVES: To develop and validate an automated noninvasive method to quantify mitral regurgitation. BACKGROUND: Automated cardiac output measurement (ACM), which integrates digital color Doppler velocities in space and in time, has been validated for the left ventricular (LV) outflow tract but has not been tested for the LV inflow tract or to assess mitral regurgitation (MR). METHODS: First, to validate ACM against a gold standard (ultrasonic flow meter), 8 dogs were studied at 40 different stages of cardiac output (CO). Second, to compare ACM to the LV outflow (ACMa) and inflow (ACMm) tracts, 50 normal volunteers without MR or aortic regurgitation (44+/-5 years, 31 male) were studied. Third, to compare ACM with the standard pulsed Doppler-two-dimensional echocardiographic (PD-2D) method for quantification of MR, 51 patients (61+/-14 years, 30 male) with MR were studied. RESULTS: In the canine studies, CO by ACM (1.32+/-0.3 liter/min, y) and flow meter (1.35+/-0.3 liter/min, x) showed good correlation (r=0.95, y=0.89x+0.11) and agreement (deltaCO(y-x)=0.03+/-0.08 [mean+/-SD] liter/min). In the normal subjects, CO measured by ACMm agreed with CO by ACMa (r=0.90, p < 0.0001, deltaCO=-0.09+/-0.42 liter/min), PD (r=0.87, p < 0.0001, deltaCO=0.12+/-0.49 liter/min) and 2D (r=0.84, p < 0.0001, deltaCO=-0.16+/-0.48 liter/min). In the patients, mitral regurgitant volume (MRV) by ACMm-ACMa agreed with PD-2D (r= 0.88, y=0.88x+6.6, p < 0.0001, deltaMRV=2.68+/-9.7 ml). CONCLUSIONS: We determined that ACM is a feasible new method for quantifying LV outflow and inflow volume to measure MRV and that ACM automatically performs calculations that are equivalent to more time-consuming Doppler and 2D measurements. Additionally, ACM should improve MR quantification in routine clinical practice.

Non-NASA Center↗

Web Map Services (WMS) Global Mosaic

The WMS Global Mosaic provides access to imagery of the global landmass using an open standard for web mapping. The seamless image is a mosaic of Landsat 7 scenes; geographically-accurate with 30 and 15 meter resolutions. By using the OpenGIS Web Map Service (WMS) interface, any organization can use the global mosaic as a layer in their geospatial applications. Based on a trade study, an implementation approach was chosen that extends a previously developed WMS hosting a Landsat 5 CONUS mosaic developed by JPL. The WMS Global Mosaic supports the NASA Geospatial Interoperability Office goal of providing an integrated digital representation of the Earth, widely accessible for humanity's critical decisions.

web map services↗

Calibration Issues and Operating System Requirements for Electron-Probe Microanalysis

Instrument purchase requirements and dialogue with manufacturers have established hardware parameters for alignment, stability, and reproducibility, which have helped improve the precision and accuracy of electron microprobe analysis (EPMA). The development of correction algorithms and the accurate solution to quantitative analysis problems requires the minimization of systematic errors and relies on internally consistent data sets. Improved hardware and computer systems have resulted in better automation of vacuum systems, stage and wavelength-dispersive spectrometer (WDS) mechanisms, and x-ray detector systems which have improved instrument stability and precision. Improved software now allows extended automated runs involving diverse setups and better integrates digital imaging and quantitative analysis. However, instrumental performance is not regularly maintained, as WDS are aligned and calibrated during installation but few laboratories appear to check and maintain this calibration. In particular, detector deadtime (DT) data is typically assumed rather than measured, due primarily to the difficulty and inconvenience of the measurement process. This is a source of fundamental systematic error in many microprobe laboratories and is unknown to the analyst, as the magnitude of DT correction is not listed in output by microprobe operating systems. The analyst must remain vigilant to deviations in instrumental alignment and calibration, and microprobe system software must conveniently verify the necessary parameters. Microanalysis of mission critical materials requires an ongoing demonstration of instrumental calibration. Possible approaches to improvements in instrument calibration, quality control, and accuracy will be discussed. Development of a set of core requirements based on discussions with users, researchers, and manufacturers can yield documents that improve and unify the methods by which instruments can be calibrated. These results can be used to continue improvements of EPMA.

Carpenter, P.↗

Digital design using selection operations

A digital integrated circuit chip is designed by identifying a logical structure to be implemented. This logical structure is represented in terms of a logical operations, at least 5% of which include selection operations. A determination is made of logic cells that correspond to an implementation of these logical operations.

Whitaker, Sterling R.↗

User Interactive Software for Analysis of Human Physiological Data

Ambulatory physiological monitoring has been used to study human health and performance in space and in a variety of Earth-based environments (e.g., military aircraft, armored vehicles, small groups in isolation, and patients). Large, multi-channel data files are typically recorded in these environments, and these files often require the removal of contaminated data prior to processing and analyses. Physiological data processing can now be performed with user-friendly, interactive software developed by the Ames Psychophysiology Research Laboratory. This software, which runs on a Windows platform, contains various signal-processing routines for both time- and frequency- domain data analyses (e.g., peak detection, differentiation and integration, digital filtering, adaptive thresholds, Fast Fourier Transform power spectrum, auto-correlation, etc.). Data acquired with any ambulatory monitoring system that provides text or binary file format are easily imported to the processing software. The application provides a graphical user interface where one can manually select and correct data artifacts utilizing linear and zero interpolation and adding trigger points for missed peaks. Block and moving average routines are also provided for data reduction. Processed data in numeric and graphic format can be exported to Excel. This software, PostProc (for post-processing) requires the Dadisp engineering spreadsheet (DSP Development Corp), or equivalent, for implementation. Specific processing routines were written for electrocardiography, electroencephalography, electromyography, blood pressure, skin conductance level, impedance cardiography (cardiac output, stroke volume, thoracic fluid volume), temperature, and respiration

Cowings, Patricia S.↗