Search NASA⌕ Search

SEARCH · Search NASA

Results for “Distributed Energy Resource Management”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 163 records · Page 9

Overview of Fish Passage Facilities at Hydropower Developments across the Conterminous United States

This dataset contains geo-referenced information on the presence and types of fish passage facilities at hydropower developments across the conterminous United States (CONUS) presented in the ORNL Hydropower Fish Passage Database Webmap (https://www.ornl.gov/project/quantifying-national-fish-passage-data/webmap). It was developed through collaborative partnerships with fish passage engineers and biologists at both the US Fish and Wildlife Service (USFWS) and the National Marine Fisheries Service (NMFS), and hydropower experts at the Low Impact Hydropower Institute (LIHI). Information contained within this dataset has been provided by many different sources, including State and Federal resource management agencies, non-governmental organizations, hydropower industry members, and published datasets=. This dataset is intended to provide a high-level overview of the distribution of fish passage infrastructure at hydropower developments across CONUS; a more comprehensive database is anticipated to be released later in 2025. This dataset contains one data file in comma-separate (*.csv) format and the information within it was last updated on 24 March 2025.

13 HYDRO ENERGY↗

Developing Smart Building Technology Modules to Enhance Workforce Preparedness: A Case for AI-Driven Academic and Professional Education

Smart building technologies are resources that improve building energy efficiency and resilience, reduce carbon emissions, and provide load flexibility to the grid. However, in both academic curricula and building professionals’ continuing education, there is a lack of systematic instruction on methods to integrate multiple energy systems including distributed energy resources (DER), smart building technologies, AI (Artificial Intelligence) tools and key concepts, components, and controls, including “Internet of Things” (IoT) devices. In today’s dynamic workforce, this major gap in smart building technology education prevents stakeholders from being able to attract talent with an understanding and preparation to adopt smart building technologies in building design and operations. A federally funded project included a partnership between Slipstream and Texas A&M University (TAMU) to develop a semester-long smart building curriculum for engineering college students with the ability to adapt the contents for workforce development of professionals in building services. The final product consists of 16 training videos adapted for building professionals and the public. The educational content and training materials cover the benefits of building energy systems, the latest sensor technologies and IoT devices, all with a focus on smart building technologies. The key drivers are on topics related to smart building controls (i.e., energy management information systems), smart building control platforms, cybersecurity, grid-interactive-efficient buildings (GEBs), smart building control methods, and occupant-centric control. Although not explicitly included the technologies nod to the need for AI driven technologies to prepare engineers and industry professionals to be future ready. This paper describes the project approach, provides outlines of the training materials, and identifies lessons learned in creating the content for this course. The authors suggest ways to scale the instruction of smart building concepts to empower the workforce to accelerate the adoption of smart building technologies and AI-based teaching and learning in higher education and building sector.

99 GENERAL AND MISCELLANEOUS↗

A Fast Dynamic Internal Predictive Power Scheduling Approach for Power Management in Microgrids: Preprint

This paper presents a Dynamic Internal Predictive Power Scheduling (DIPPS) approach for optimizing power management in microgrids, particularly focusing on external power exchanges among diverse prosumers. DIPPS utilizes a dynamic objective function with a time-varying binary parameter to control the timing of power transfers to the external grid, facilitated by efficient usage of energy storage for surplus renewable power. The microgrid power scheduling problem is modeled as a mixed-integer nonlinear programming (MINLP-PS) and subsequently transformed into a mixed-integer linear programming (MILPPS) optimization through McCormick's relaxation to reduce computational complexity. A predictive window window with 6 data points is solved at an average of 0.92s, a 97.6% improvement over the 38.27s required for the MINLP-PS formulation, implying the numerical feasibility of the DIPPS approach for real-time implementation. Finally, the approach is validated against a static objective using real-world load data across three case studies with different time-varying parameters, demonstrating the ability of DIPPS to optimize power exchanges and efficiently utilize distributed resources while shifting the external power transfers to specified time durations.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Optimizing and Exploring Untapped Micro-Hydro Hybrid Systems: a Multi-Objective Approach for Crystal Lake as a Large-Scale Energy Storage Solution

Increasing electricity demand and concerns about climate change and fossil fuel consumption have highlighted the importance of renewable energy resources and storage systems. This paper proposes a method for exploring untapped pumped hydro storage potentials to accommodate intermittent renewable energy generation profiles. Hourly measured data from 2022 in Benzie County, Michigan, United States, were gathered for system sizing and a thorough, realistic analysis. By employing the multi-objective grey wolf optimization algorithm, we formulated optimal sizing and energy-management strategies for three different scenarios. Unlike similar studies, the 3rd with triple objective functions (OFs) scenario aims to maximize both reliability and ecological OFs while minimizing the cost OF. It has shown promising results with multiple solutions, considering economic, environmental, and reliability factors. A case study conducted in Crystal Lake, Michigan, revealed that although Crystal Lake would function only as a micro-hydro power facility, it is a promising and huge storage unit with a substantial storage capacity of around 14.9734GWh. The system investigated is significant in the USA due to its rapid deployment capabilities, minimal construction requirements, and ease of integration with the distribution grid. The fuzzy logic method was employed to identify the best non-dominant solution among the other solutions. Furthermore, these outcomes include a notably low levelized cost of energy at 0.046147$/kWh, a robust index of reliability of 99.705%, and a significant reduction in CO₂ emissions amounting to 7.9142×10 3 tons/year, when considering the triple OFs. The paper’s methodology provides valuable insights for regions aiming to utilize renewable energy from untapped storage sources.

13 HYDRO ENERGY↗

Quantum/AI Topology-Aware Latency-Adaptive HPC Workflow Scheduling Optimization

The growing demand for more powerful high-performance computing (HPC) systems has led to a steady rise in energy consumption by supercomputing worldwide. This study is focused on comparing our Application-Topology Mapper (ATMapper) to the popular Simple Linux Utility for Resource Management (SLURM) for the purpose of exploring methods that can further optimize job-scheduling within HPC systems. ATMapper is an Artificial-Intelligence based approach to job-scheduling that is currently being enhanced with quantum annealing (QA) to generate optimal schedules faster. We are applying QA to speedup our ATMapper process to achieve higher computing efficiency, thereby reducing HPC energy consumption. Here, we examine how four job-scheduling approaches perform in processor node assignment when using an example network architecture of 4 interconnected nodes. Using a specialized script, we are assessing the schedule of a computation flow with 11 interdependent tasks. The data movements among nodes were tracked to count for the number of interactions (network hops) between nodes needed to complete the tasks. The total number of hops and the job completion time were then used to quantify the efficiency of the different mapping approaches. In addition to SLURM, we also compare our ATMapper to the QA-enabled LBNL TIGER and the D-Wave Distributed Computing processor assignment approaches. The preliminary results showed that our topology-aware, latency-adaptive ATMapper is significantly more efficient when compared to the other scheduling approaches due to its load-imbalance network allocation. The scheduler displayed a computing efficiency of 53% by performing significantly fewer network hops than its alternatives. By reducing the number of hops, ATMapper was able to perform all 11 tasks by using only 3 nodes out of given 4. This research indicates the potential to use QA/AI for HPC job-scheduling. Later, we will test a SLURM simulator program to draw further comparisons on the effectiveness of ATMapper's scheduling approach. The results of this comparison will serve as a baseline for later improving SLURM's performance using a QA-enhanced ATMapper approach.

Caraveo, Braulio [University of Huston - Clear Lak↗

Unalakleet Microgrid Optimization for Tribal Community Resilience

The Unalakleet Microgrid Optimization Project aimed to strengthen the reliability and efficiency of the isolated electric power system that serves the Tribal community of Unalakleet, Alaska. The community relies entirely on a local wind-diesel microgrid, consisting of four 475 kW diesel generators and six 100 kW wind turbines, to provide electricity to approximately 745 residents and Tribal facilities. Because Unalakleet is not on a road system and is located nearly 400 miles from the nearest major power grid, maintaining a resilient and efficient local energy system is critical. The scope of this project included upgrading a portion of the transmission line between the wind farm and the power plant to increase voltage and reduce line losses, along with modernizing the Supervisory Control and Data Acquisition (SCADA) system to improve monitoring, control, and data management of the power system. These upgrades were designed to increase wind energy utilization, reduce diesel fuel consumption by tens of thousands of gallons annually, and improve overall grid stability. By allowing more of the community’s electricity to be supplied by local renewable wind resources, the project was designed to lower operating costs, reduce dependence on imported fuel, and strengthen the long-term resilience of the power system. These improvements represent an important step toward the community’s long-term energy vision of expanding renewable generation, incorporating energy storage, and eventually achieving “diesels-off” operation, where essential Tribal loads are powered primarily by local renewable resources.

17 WIND ENERGY↗

Regional inertia dynamics of U.S. interconnections: An event-based measurement approach

Power grid inertia plays a vital role in frequency stability following large disturbances, yet its distribution across the U.S. grid is highly uneven. While interconnection-wide inertia benchmarks are useful, they can mask regional variability driven by resource mix, network coupling, and geographic separation. This paper extends event-driven inertia estimation to the regional scale using field measurements from the Frequency Monitoring Network (FNET/GridEye). Starting from balancing authority and independent system operator footprints, candidate regions are refined using a composite coherency score that combines frequency-trajectory shape similarity, timing spread, and lead/lag behavior to ensure dynamic consistency. A filtered sliding difference method (FSDM) is then used to construct regional frequency trajectories, detect disturbance onset, and compute robust regional rate-of-change of frequency (RoCoF). Regional, local, and interconnection inertia are estimated by combining RoCoF with event power imbalance, and additional indicators (regional-to-system inertia ratio and inertial-support arrival time) quantify regional-to-interconnection coupling and relative regional contributions. The method is demonstrated on eleven regions across the Eastern Interconnection (EI) and the Western Electricity Coordinating Council (WECC), with the Electric Reliability Council of Texas (ERCOT) used for validation. In ERCOT, estimates compared against energy management system (EMS) values achieve a mean absolute percentage error of 17.94%. WECC exhibits consistently shorter inertial-support arrival times (0.15–0.3 s) than EI (0.7–1.1 s), highlighting contrasting coupling and disturbance-propagation behavior. Overall, the results reveal pronounced spatial heterogeneity in inertia and coupling, underscoring the value of regional monitoring for both operational decision-making and long-term system planning.

Disturbance events↗

Enhancing SWAT with mechanistic plant hydraulics: development and application in the Hanjiang River Basin

Plant transpiration plays a critical role in global water and energy cycles, requiring better process understanding as climate change intensifies drought stress and alters plant responses. Most hydrological models such as the widely-used SWAT lack representation of plant hydraulics, the mechanistic processes controlling plant water regulation and transpiration. Here, this study developed SWAT-PHS by integrating a plant hydraulics scheme (PHS) into SWAT hydrological model, enabling explicit simulation of root water uptake, sap flow, storage and transpiration at 30-minute timescales for watershed-scale modeling. In the Hanjiang River Basin, SWAT-PHS mitigated overestimation of runoff during the rainy season and underestimation during the dry season, reducing the overall simulation error by 29% across the entire simulation period. The model can simulate reasonable plant water dynamics, including diurnal transpiration patterns and drought responses showing declining transpiration flux, hydraulic buffering through stem water storage, and depth-dependent root water uptake strategies. Sensitivity analysis shows that SWAT-PHS captured mechanistic relationships between plant hydraulic traits and transpiration, with root distribution and stem capacitance positively affecting annual transpiration while vulnerability parameters showed negative effects. This work provides a pathway for improving hydrologic modeling and water resource management by better representing plant water regulation under climate change and expected intensifying water stress conditions.

China↗

An Innovative Energy Management System for Microgrids with Multiple Grid-Forming Inverters

As increasingly more grid-forming (GFM) inverter-based resources replace traditional fossil-fueled synchronous generators as the GFM sources in microgrids, the existing microgrid energy management systems (EMS) need to be updated to control and coordinate multiple GFM inverters that consider system control objectives under different microgrid connection states. For each state, we formulate an optimization problem and apply a real-time feedback-based control algorithm; altogether, the control algorithms seamlessly connect the states into a generic microgrid EMS that controls the nodal voltages and frequencies, becomes a virtual power plant (VPP) when connected to the main grid, and coordinates power sharing responsibility among GFM sources when islanded. We showcase the EMS on a real-world simulation of a microgrid under the different states to demonstrate its operational effectiveness.

energy management systems↗

An Innovative Energy Management System for Microgrids with Multiple Grid-Forming Inverters

As increasingly more grid-forming (GFM) inverter-based resources replace traditional fossil-fueled synchronous generators as the GFM sources in microgrids, the existing microgrid energy management systems (EMS) need to be updated to control and coordinate multiple GFM inverters that consider system control objectives under different microgrid connection states.For each state, we formulate an optimization problem and apply a real-time feedback-based control algorithm; altogether, the control algorithms seamlessly connect the states into a generic microgrid EMS that controls the nodal voltages and frequencies, becomes a virtual power plant (VPP) when connected to the main grid, and coordinates power sharing responsibility among GFM sources when islanded. We showcase the EMS on a real-world simulation of a microgrid under the different states to demonstrate its operational effectiveness.

energy management system↗

Potential Impacts of Dynamic Electricity Pricing in California: Load Shape and Customer Bill Impacts Under Elastic Customer Response

The increasing penetration of renewable energy in California has intensified grid management challenges, exemplified by the “duck curve” and the resulting need for steep ramping and curtailment of renewables. To address these issues, dynamic electricity tariffs that vary in near-real time are being considered to incentivize customers to shift demand and support the grid. This study extends previous work on the bill impacts of such tariffs in the absence of load response by quantifying the system-level and customer impacts of load response based on customer price elasticity. Customer-level load response modeling was conducted using meter data from 411,000 customers across residential, commercial, and industrial sectors. Customer demand elasticity was estimated using literature-based values, with scenarios ranging from low to high elasticity, including an automation-enhanced scenario. Results indicate that universal adoption of, and response to, dynamic tariffs can significantly reduce peak net load (by 15%) and maximum ramping requirements (by 20%) with moderate elasticity, delivering demand response resources comparable to or exceeding current programs at all elasticity levels. Bill analysis shows that, when responding elastically to dynamic prices, most non-PV customers experience modest savings, while PV customers may see higher effective rates due to lower compensation for exports during low-price periods. Emissions analysis reveals a reduction in per-kWh emissions system-wide, with a total absolute load increase of 2% accompanied by a negligible absolute emissions increase. The study concludes that while dynamic tariffs offer substantial grid benefits, customer bill savings under modeled response behaviors may be too modest to drive widespread adoption without additional incentives or enabling technologies. Future research should model flexible loads and advanced control technologies with greater fidelity to better represent the potential opportunities of dynamic tariffs.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Powered By CADET

The Capacity Expansion Decision Support for Distribution Networks (CADET) is a Python-based library and framework for creating electrical distribution system capacity planning tools for cost-effective, reliable power delivery. It enables the creation of modular, scalable, and extensible distribution capacity planning tools by providing a high-level optimization interface, parameter and options data managers, optimization constraint and objective libraries, generalized nomenclature, a system for tracking and modifying distribution network changes, optimization solution validation, and other capabilities. This webinar will describe 1) the motivation for creating CADET, 2) key designs, and 3) several use cases.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Dispatching Grid-Forming Inverters in Grid-Connected and Islanded Mode

This paper explores the dispatchability of grid-forming (GFM) inverters in grid-connected and islanded mode. GFM inverters usually use droop control to automatically share power with other GFM sources (inverters and synchronous generators) and follow the change in the load demand; however, they can be dispatched like their grid-following (GFL) counterparts to output the target active and reactive power. This will help grid operators better manage their inverter-based resources (IBRs) to improve operation efficiency and reliability; therefore, this paper proposes an innovative concept of dispatching GFM sources (inverters and synchronous generators) to output the target power in both grid-connected and islanded mode by adjusting their droop intercepts. The fundamental principle is that the GFM inverter's active and reactive power is dictated by its frequency and voltage, and thus dispatching the active and reactve power of a GFM inverter can be achieved through dispatching its frequency and voltage. Moreover, the concept distinguishes the dispatch rules for grid-connected and islanded mode. Finally, the concept is validated with an example microgrid system with two GFM inverters, one diesel generator, one GFL inverter, and the load in both grid-connected and islanded mode. This pioneering work results in practical guidance for the development of energy management systems for future electric grids with GFM and GFL inverters.

dispatching↗

Energy Services Interface: Architecture, Requirements, and Agreements

This report continues and extends the development of the Energy Services Interface (ESI) that recently has been led by the U.S. Department of Energy’s Grid Modernization Laboratory Consortium. The ESI is intended to facilitate the coordination of multiple, flexible energy resources that work in tandem to satisfy grid objectives by using performance attributes encoded within an ESI Service Template. The ESI relies on a pair of interfaces, representing the service requestor (the consumer of a service) and a service provider (who manages its resources per the agreed performance attributes) to achieve what is commonly known as a “grid service”. Due to its performance-driven approach, the ESI is hypothesized to be able to satisfy all common grid needs via only six common ESI service types. This report first reviews the status of ESI development, including its fundamental tenets. The report makes three important contributions to ESI development: First, it recognizes the similarity between service level agreements and the contract-like agreements that would be needed between energy service requestors and providers and recommends that ESI service agreements be modeled after the web services agreement specification. Second, whereas prior development efforts had focused on a flat, five-stage lifecycle, this report asserts that the ESI should have three behavioral layers in its architecture—the discovery, agreement, and service layers. Finally, this report offers concrete requirements that should be useful toward the development of the service requestors’ and service providers’ respective communications interfaces.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Adaptive Protection and Validated Models to Enable Deployment of High Penetrations of Solar PV (PV-MOD)

The availability and validation of various PV models in commercial tools differ, with some models not yet thoroughly validated for advanced inverter functionalities and reliable performance under weak system conditions. Many existing models do not fully incorporate new inverter control functions, which can affect system stability. The increasing deployment of solar PV and other inverter-based resources (IBRs), including distributed energy resources (DERs), is influencing the reliable operation of protection schemes in distribution systems and microgrids. Emerging adaptive protection schemes (APS) offer new opportunities for protecting these systems during varying configurations and DER operating conditions, though their demonstration and validation remain limited. Adaptive protection schemes face similar challenges, as they are typically designed for specific configurations. There is a growing need for tools and methodologies to streamline the deployment of adaptive protection for safe and reliable DER integration. The project main objective was to develop and validate high-fidelity generic models of solar PV facilities for stability, protection, EMT, and QSTS analyses. This objective was achieved, and these models can now be integrated into commercial software tools, enabling utilities, vendors, and developers to study high-penetration PV systems more confidently. The project also demonstrated advanced applications of these models, including the design and deployment of adaptive protection schemes in high-penetration field applications and microgrids, supporting grid safety and reliability. Several milestones were reached by the end of the project. A sophisticated inverter test plan was developed, and inverters representative of the North American marketplace were selected. EPRI and NREL tested various inverters, conforming to IEEE standards. Improvements were made to existing generic models of IBR units, IBR plants, and aggregated feeders for various analyses. The first generic electromagnetic transient (EMT) model for a solar PV plant was developed, conforming to IEEE Std 2800™-2022 and validated against laboratory measurements of a 2.2 MVA large-scale battery energy storage system (BESS) inverter. That model was then used to produce reference responses illustrating examples of validated and verified IBR plant models that pass or fail tests for technical minimum capability and performance as specified in the IEEE standard. The developed, tested, and validated generic models can be used for transmission planning, stability assessments, expansion planning, and evaluating potential future IBR interconnection requirements. They can also support interconnection screens and conformity assessments of IBR plants, including solar PV. The project significantly contributed to the ongoing standardization and model-based representation and verification of IBR responses. The project further addressed challenges of common distribution protection schemes with increasing deployment of DER by developing, validating, and demonstrating adaptive protection schemes (APS) that can improve the reliable and safe integration of DER into distribution systems. New APS were designed using improved DER models for three common distribution systems: a radial feeder, a meshed network, and a microgrid. Modeling and hardware-in-the-loop (HIL) testing of the APS were conducted, successfully showing their effectiveness and selectivity. Proof-of-concept field demonstration was achieved for two APS, i.e., one on a radial feeder and another one in a microgrid. Field demonstration could not be achieved for the APS on a meshed network, primarily due apprehension of one utility partner and also due to limited access to the protective algorithms in the network protectors. Guidelines developed from the lessons learned in the project lay out the general process followed in the design, installation, and commissioning of APS for various distribution systems. Distribution utility partners’ apprehension about field demonstration of the new APS were addressed—with varying success—by taking a stepped risk-management approach of modeling of a wide range of sensitivities first, performing in-depth proof-of-concept testing in the laboratory including HIL next, and finally deliberately implementing and commissioning the actual protection equipment and algorithms into parts of—or in parallel operation to—the three real distribution systems. Future work should include pilot projects that further show the acceptable performance of the developed APS before these schemes be rolled out more widely. Inclusion of both utility and original equipment manufacturers (OEMs) in future projects could increase chances of successful field demonstration. Despite challenges in achieving the field demonstration goal of the project for all three APS, the research significantly contributed to the innovation of adaptive protection solutions for scalable and reliable DER integration into distribution systems. This project significantly enhances the understanding of the impact of using appropriate inverter models on distribution and transmission (T&D) systems. By addressing the limitations of existing generic models, the project introduces high-fidelity models for stability, protection, electromagnetic transient (EMT), and quasi-static time series (QSTS) analyses. These models, integrated into commercial software tools, enable utilities, vendors, and developers to confidently study high-penetration PV systems. The project also demonstrates advanced applications, including adaptive protection schemes (APS) for distribution systems and microgrids, ensuring grid safety and reliability. The technical effectiveness and economic feasibility of the methods are evident through the development and validation of sophisticated inverter test plans and the selection of representative inverters. Testing by EPRI and NREL on retail, commercial, and utility-scale inverters, conforming to IEEE standards, underscores the robustness of the models. Improvements to existing generic models for various analyses further enhance their validity and applicability. The project also identifies gaps in common distribution protection schemes and designed new APS using improved DER models, demonstrating their effectiveness through modeling and hardware-in-the-loop (HIL) testing. The project’s benefits to the public are manifold. By advancing the standardization and model-based representation of IBR response, it supports transmission planning, stability assessments, and future IBR interconnection requirements. The generic models can facilitate better communication between transmission planners and developers, supporting expected IBR plant capability and performance. Additionally, the development of APS for radial feeders, meshed networks, and microgrids supports the integration of distributed energy resources (DERs) into distribution systems, enhancing grid reliability and safety. The project’s emphasis on thorough testing and simplicity in design ensures practical and scalable solutions for DER integration.

14 SOLAR ENERGY↗

Dispatching Grid-Forming Inverters in Grid-Connected and Islanded Mode: Preprint

This paper explores the dispatch-ability of grid-forming (GFM) inverters in grid-connected and islanded mode. Grid-forming (GFM) inverters usually use droop control to automatically share power with other GFM sources (inverters and synchronous generator (SG)) and follow the change of the load demand. However, they can be dispatched like their grid-following (GFL) counterparts to output the target active and reactive power. This will help the grid operator better manage their inverter-based resources (IBRs) for improved operation efficiency and reliability. Therefore, this paper proposes an innovative concept of dispatching GFM sources (inverters and SG) to output the target power for both grid-connected and islanded mode by adjusting their droop intercepts. The fundamental principle of doing so is that the GFM inverter's active and reactive power is dictated by its frequency and voltage, thus, dispatching active and reactve power of a GFM inverter can be achieved through dispatching its frequency and voltage. Moreover, the concept distinguishes the dispatch rules for grid-connected and islanded mode. Finally, the concept is validated with an example microgrid system with two GFM inverters, one diesel generator, one grid-following inverter and loads in both grid-connected and islanded mode. This pioneering work results in a practical guidance for power system energy management system (EMS) development to control a future grid with GFM and GFL inverters.

droop control↗

Packages of Distributed Energy Technologies Demonstrating Demand Flexibility at Community Scale

The combination of increased electric load growth across all sectors, deferred electrical infrastructure investment, and other factors resulting in variable electric power supply, has created technical challenges to maintaining a resilient and reliable grid. Many federal, regional, and local efforts are in play to modernize the electric grid, including advancing building technologies and distributed energy resources (DERs) that are utilizing smarter controls to become responsive to both occupant and grid needs. This report reviews ten pilot projects demonstrating how groups of buildings combined with behind-the-meter (BTM) DERs such as electric vehicle (EV) charging, battery storage, flexible HVAC and domestic hot water systems, and photovoltaic systems can reliably and cost effectively provide grid services. Each of the ten pilot projects aim to deliver both energy efficiency and demand flexibility (DF) while supporting load growth. The ten demonstration teams are piloting flexible DER packages across diverse communities of residential and commercial buildings to address a variety of regional grid needs. The outcomes of these pilot projects will be used to inform future scaling through utility program development. This paper characterizes the ten teams, showcasing the decision-making process used by each group to develop their packages (Section 2), the grid services they plan to deliver (Section 3), the types of DER packages selected for deployment within building sectors (Section 4) and trends between building sector, DER types, and grid services In order to achieve community scale benefits, the pilot projects must utilize aggregated control mechanisms for coordinating buildings and DERs together. Several types of coordinated control architectures have evolved amongst the teams, influenced by use type, existing market conditions, and integration type. Three coordinated controls architectures have been characterized, highlighting their use cases, benefits, challenges, and tradeoffs in their design. These insights can aid utilities, control vendors, and developers in scaling community-level energy systems (Paul, 2024). Ultimately, the technology packages selected by the ten teams will be coordinated to provide power system services, also known as grid services. Insights from these demonstrations will be useful for grid operators, regulators, aggregators and other stakeholders as they look to deploy demand flexible resources as grid services in the future. The grid services that each team is targeting for demonstration are described in Section 3 and Section 4. Methods for evaluating the grid services have been described in the paper Metrics for Evaluating Grid Service Provision from Communities of Grid-interactive and Efficient Buildings and other DER (MacDonald, 2023). To identify technology packages for demonstration, Section 2 shows that project teams used a range of analysis approaches, including building energy modeling, AMI data analysis, cost-benefit frameworks, and utility pilot data. Some teams emphasized technical modeling to quantify grid impacts and demand reduction potential, while others prioritized economic evaluations, stakeholder input, or exploratory pilots to inform deployment decisions. This diversity reflects the need to tailor selection methods to project goals, available data, and organizational context. Section 5 discusses trends between the DER technologies deployed and the grid service provisions from each team. Residential buildings (multifamily and single family) lean towards technologies that enhance energy efficiency (e.g. weatherization upgrades, smart thermostats) and onsite power generation integration (e.g. solar PV). Commercial building demonstrations prioritize technologies that ensure operational reliability (e.g. battery storage) and centralized energy management systems and optimization solutions. Teams that are deploying controllable storage-based technologies are more likely to provide grid services that require a near real-time response. Teams incorporating load shifting technologies like smart thermostats with HEMs are likely to include energy markets participation and customer bill management offerings. Campus demonstrations are adopting diverse sets of DERs to emphasize renewable generation, paired with centralized control. This section also describes technologies that were considered during project planning but ultimately excluded from final deployment. These demonstrations reveal that effective DER package design should be tailored to building type, customer segment, and construction vintage. Multifamily buildings benefit from centralized HVAC upgrades and supervisory controls, while single-family homes are well-suited for individualized technologies like solar, storage, and smart home energy monitors. Commercial and campus settings prioritize EMIS integration and load optimization. New construction enables cost-effective integration of DER-ready infrastructure, whereas retrofits require deployments aligned with owner and tenant value streams. For utility program planners, early coordination with developers and building owners, paired with segmented and modular program offerings, can improve adoption, scalability, and grid impact.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Valuing the Future Electric Grid: A Bid-Based Approach

Energy storage resources (ESRs) and other zero marginal cost (ZMC) resources have unique characteristics that are not fully captured in today’s electricity planning and operations modeling tools. Because the modeling assumptions used in these tools are simplified approximations of how operations and investment decisions occur in the real-world, accurately representing cost and operational characteristics are key for determining how these resources impact price formation. Questions such as—Where should we build new transmission? Will a small modular reactor earn enough revenue to participate in the future electric grid? Is retrofitting a coal plant with carbon capture technology economically feasible?—all require accurate electricity prices, which aren’t available from today’s electricity planning and operations modeling tools. As an example, production cost models (PCMs) are heavily utilized tools that determine the cost and reliability of the electric system. However, as PCMs were developed to help thermal generators manage their fuel inventories, production cost modeling is largely based on fuel prices. Because ESRs do not incur fuel costs, they are often modeled as ZMC resources. In reality, ESRs incur opportunity costs as well as technology-specific (degradation) costs that are non-trivial to calculate but are important for price formation. In this research, we identify options to incorporate more realistic opportunity and degradation costs in ESR bidding algorithms. Expanding available bidding assumptions allows energy system modelers to develop more accurate economic valuations for ESRs, leading to more accurate price formation from leading energy system modeling tools.

24 POWER TRANSMISSION AND DISTRIBUTION↗