Search NASA⌕ Search

SEARCH · Search NASA

Results for “ELECTRONIC EQUIPMENT”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 163 records · Page 9

Assessment of errors in analytic modeling of permanent magnet electron spectrometers for laser-plasma accelerators

Here, we assess the error in three treatments of a critical electron beam diagnostic for laser-plasma acceleration (LPA) experiments: a permanent magnet electron spectrometer. Since LPA electron spectrometers are often difficult to calibrate due to the scarcity of well-characterized, tunable electron beam sources in the appropriate energy range and the mechanical complexity of electron spectrometers, the standard of calibration is Hall probe measurements. We first compare the electron spectrometer performance between SIMION calculations and the Hall probe measurements. We find up to a 60% (<8%) error in determining the absolute energy for electrons below (above) 80 MeV when using the SIMION-modeled magnetic field vs the measured magnetic field due to SIMION overpredicting fringe field strength. The difference in spectrometer energy resolution is within ∼10% between the modeled and measured fields. We then assess a simple block model, which is commonly used. We find that the simple block model presented here sufficiently captures the predicted as-built spectrometer performance for any application provided that the user can tolerate uncertainties on absolute energy determination up to 5% and errors on energy resolution up to 1%.

Electromagnetic optics↗

Opportunities for imaging light nuclei with a second interaction region at the Electron-Ion Collider

The upcoming Electron-Ion Collider (EIC) will address several outstanding puzzles in modern nuclear physics. Key questions—such as the partonic structure of nucleons and nuclei and the origin of their mass and spin—can be explored through high-energy electron-proton and electron-nucleus collisions. Here, to maximize its scientific reach, the EIC community has advocated for the addition of a second interaction region equipped with a detector complementary to the EIC general purpose collider detector, ePIC. The preconceptual design of this interaction region aims to provide a different configuration from the first interaction region, which enhances forward acceptance at very small scattering angles (𝜃 ∼0 mrad). This machine configuration would significantly benefit exclusive, tagging, and diffractive physics programs, complementing those of the ePIC experiment. In particular, accessing coherent diffractive processes on light nuclei by tagging of the full, intact nucleus is essential for mapping their spatial parton distributions. In this work, we present an exploratory study of the detection capabilities for light nuclei at a second EIC interaction region, with a detailed discussion of the accessible kinematic phase space and its implications for imaging.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Electron Ion Collider Machine Protection System: Requirements for an Electron Storage Ring abort system

The Electron Ion Collider (EIC) accelerator complex includes multiple high-energy high-power accelerators [1]. Operation of such a complex is associated with numerous hazards and risks of possible damage to the equipment. The EIC machine protection system (MPS) scope is to protect the components of each accelerator from damage by the beam. The EIC MPS design, commissioning and operation is closely interconnected with the protection of various accelerator subsystems, such as RF-system, cryogenics, vacuum system etc. Yet, the primary goal of the MPS is to protect the EIC accelerators from the possible damage caused by electron and proton beams.

43 PARTICLE ACCELERATORS↗

Synthesis and functionalization of electron-deficient perfluoroalkyl porphyrin building blocks for supermolecular systems

Synthetic strategies for electron-deficient meso-perfluoroalkylporphyrins bearing diverse functional groups are described. Scalable and efficient syntheses for 5-triisopropylsilylethynyl-10,15,20-tris(heptafluoropropyl)porphyrin and 5-triisopropylsilylethynyl-10,20-bis(heptafluoropropyl)porphyrin that equip meso-ethynyl functional groups via the bilane route have been established, along with a refined route to [5,15-bis(heptafluoropropyl)porphinato]zinc(II). meso-Position halogenation of [5,15-bis(heptafluoropropyl)porphinato]zinc(II) was achieved by selective meso-nitration and subsequent reduction, diazonium salt formation, and iodination reactions. Computational data describe the low energy excited states of these chromophores and the electronic structural factors that control reactivity of these meso-perfluoroalkyl substituted porphyrin complexes. meso-Functionalized [5-triisopropylsilylethynyl-10,20-bis(heptafluoropropyl)porphinato]zinc(II) and [5-iodo-10,20-bis(heptafluoropropyl)porphinato]zinc(II) building blocks lay the foundation for the construction of highly conjugated multiporphyrin arrays that feature electronic structural properties important for the development of n-type materials and high potential photooxidants.

Chemistry↗

Electron density measurements and calculations in a helium capacitively-coupled radio-frequency plasma

We report a comparison of inferred electron density (n e ) in a He capacitively-coupled plasma, deduced from laser-collision induced fluorescence measurements, with values computed using a hybrid simulation framework based on particle-in-cell/Monte Carlo collisions simulations and a fluid model for excited He atoms. The studies were carried out for gas pressures between 50 mTorr and 1000 mTorr and peak-to-peak radio-frequency (13.56 MHz) voltages between 150 V and 350 V, in a highly symmetric source equipped with plane-parallel electrodes. A good agreement is found between the experimental and modeling results for n e except at the lowest operating voltages and gas pressures. The (effective) electron temperature (T e ) values derived by the two methods agree as well reasonably within the plasma bulk. The simulation results are used to compare the density distributions of He + and various He excited levels and their major populating and de-populating channels at 100 mTorr and 1000 mTorr.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

TiltEM User Manual

The ability to automate the scanning transmission electron microscope (S/TEM) is tantamount to addressing next generation artificial intelligence, machine learning, and materials modeling capabilities. Constant utilization of these high-end capital equipment purchases also serves the requirements of the Department of Energy (DOE) to be fiscally responsible to the public. The development of an automated multi-modal tilt series algorithm for dark field/bright field S/TEM imaging plus chemical identification with energy dispersive x-ray spectroscopy has been achieved at PNNL. A tilt series workflow has now been generated which allows for autonomous collection of imaging and compositional information simultaneously. This advancement is due in large part to a transition from the rigid and microscope specific JEOL hardware environment, to the more adaptable GMS environment. This has thereby led to a greater degree of flexibility in the application of this method across platforms in addition to substantial time savings to the user.

47 OTHER INSTRUMENTATION↗

Horizontal 1 K refrigerator with novel loading mechanism for polarized solid targets

We describe a helium evaporation refrigerator used to cool dynamically polarized proton and deuteron targets for electron-scattering experiments using the CEBAF Large Acceptance Spectrometer CLAS12 at Jefferson Lab. The geometry of the CLAS12 detector systems places severe design and construction constraints on the refrigerator and its ancillary equipment, resulting in a horizontal cryostat with a length of 4 m. The 16 cm 3 target samples, consisting of frozen ammonia (NH 3 or ND 3 ), are loaded at the upstream end of the cryostat and moved to the beam-interaction region using a novel transport mechanism. At this location they are cooled with superfluid helium and polarized via dynamic nuclear polarization at 1 K and 5 T. In this manner samples can be replaced and cooled to 1 K in about 30 minutes without disturbing any elements of the electron beam line or particle detection system. In conclusion, we estimate that this method saved 18 days of valuable beam time over the course of a recent, 88-day long experiment.

Evaporation refrigerator↗

Design and performance of an in-vacuum, magnetic field mapping system for the Muon g-2 experiment

The Muon g - 2 experiment at Fermilab (E989) aims to measure the anomalous magnetic moment, a μ , of the muon with a precision of 140 parts-per-billion. This requires a precise measurement of both the anomalous spin precession frequency, ω α , of muons stored in a magnetic field of 1.45 T, and a precise measurement of that magnetic field in terms of the shielded proton Larmor frequency, ω' ρ . The measurement of ω' ρ with a total systematic uncertainty of 70 parts-perbillion involves a combination of various nuclear magnetic resonance (NMR) probes. There are 378 probes mounted in fixed locations that constantly monitor field drifts. A water-based, cylindrical calibration probe provides the calibration in terms of the shielded proton Larmor frequency. A crucial element for the multi-step measurement of ω' ρ is the regular mapping of the magnetic field over the muon storage region. The former experiment at Brookhaven National Laboratory (BNL) employed an in-vacuum field mapping system equipped with 17 NMR probes, which was developed by the University of Heidelberg. We have refurbished and upgraded this system with new probes and electronics. The upgrades include the addition of 16-bit, 1 MSPS digitization of the NMR signals, which replaced the hardware-implemented zero-crossing counting of the system at Brookhaven. The digitized signals offer new capabilities in the NMR frequency analysis and its related systematic uncertainties. To sustain the higher data rates, a new communication scheme with time-division multiplexing was implemented to separate the important NMR reference clock from the data communication in order to reach the specifications for the accuracy and stability of the reference clock. A new barcode reader provides more precise azimuthal position determination during the measurement and calibration. While the mechanical systems that move the field mapper inside the storage ring have been mostly refurbished from BNL, the motion control system was completely replaced with a custom-built electronics centered around a commercial Galil motion controller. Both the field mapping NMR system and its motion control were successfully commissioned at Fermilab and have been in reliable operation during the first three data taking periods of the experiment at Fermilab. Finally, this article will provide the details of the upgrades of the field mapper and its performance.

47 OTHER INSTRUMENTATION↗

Design and performance of an in-vacuum, magnetic field mapping system for the Muon g-2 experiment

The E989 Muon g-2 experiment at Fermilab aims to measure the anomalous magnetic moment, a$_\mu$, of the muon with a precision of 140 parts-per-billion. This requires a precise measurement of both the anomalous spin precession frequency, $\omega_a$, and the average magnetic field in terms of the equivalent, free proton Larmor frequency, $\omega_p$. The measurement of $\omega_p$ with a total systematic uncertainty of 70 parts-per-billion involves a combination of various NMR probes. There are 378 probes in fixed locations constantly monitoring field drifts. A water-based probe provides the calibration in terms of $\omega_p$. A crucial element for the multi-step measurement of $\omega_p$ is the regular mapping of the magnetic field over the muon storage region. The former E821 experiment at Brookhaven employed an in-vacuum field mapping system equipped with 17 NMR probes, which was developed by the University of Heidelberg. We have refurbished and upgraded this system with new probes and electronics. The upgrades include a new communication scheme incorporating time-division multiplexing to separate the important NMR reference clock from the data communication. The addition digitization of the NMR signals replaced the hardware-implemented zero-crossing counting of the E821 system. The digitized signals offer new capabilities in the NMR frequency analysis and its related systematic uncertainties. While the mechanical systems that move the field mapper around the ring have been mostly refurbished, the motion control system was completely replaced with a custom-built electronics centered around a commercial Galil motion controller. Both the field mapping NMR system and its motion control were successfully commissioned at Fermilab and have been in reliable operation during the first data taking periods. This article provides details of the upgrades of the field mapper and its performance.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Experimental evaluation of the vapor box divertor concept with an open vapor box module in Magnum-PSI

A promising approach to handle the intense plasma heat flux in the divertor region of a tokamak is the Vapor Box Divertor (VBD). Here plasma-lithium interaction creates a dense lithium vapor cloud which interacts with the incoming plasma, effectively shielding the tungsten surface beneath, therefore preventing overheating and sputtering of the tungsten and increasing the component’s lifetime. Two key steps must be addressed to validate this concept: investigating plasma-Li interactions and the transport mechanism of the latter in the presence of plasma. To explore this, a Vapor Box Module (VBM) has been designed for use with the linear plasma generator Magnum-PSI. The VBM consists of a series of three cylindrical boxes, with Li being evaporated at a controlled temperature in the central box (CB). Divertor-like plasma enters the VBM from an upstream aperture, interacts with the Li vapor cloud and exits through a downstream aperture ultimately impacting a target equipped with a calorimetry system. Optical diagnostics Thomson scattering, Filtered fast camera Imaging and optical emission spectroscopy provided information on plasma parameters in terms of electron density n e , temperature T e and plasma composition before and after this interaction. A significant reduction in plasma power was observed upon the establishment of lithium vaporization determined via cooling water calorimetry and embedded thermocouples at the downstream target. This resulted in a drop of the target temperature from ∼800 °C to ∼350 °C (57%) at the highest applied power (11.1 MW m −2 ) and CB temperature (∼700 °C). Lithium condensation at the side boxes of the VBM in combination with strong plasma momentum transfer effectively prevented upstream migration of lithium, while enhancing Li transport toward the target. The achievement of the two main goals of reducing plasma power and confining the Li in the VBM, are consistent with earlier published preliminary SOLPS-ITER simulations. This study shows that the presence of lithium in a VBD-like configuration can result in a strong reduction of power to the target surface, while at the same time the lithium vapor is effectively confined by the VBM, aided by the incoming plasma, preventing its escape from the VBM geometry. This represents a valuable step toward validating the feasibility of the VBD configuration in future fusion reactors.

Magnum-PSI↗

Construction of Cryogen-Free 4.3T Superconducting Wiggler for NSLS-II Ring

With the 3 GeV electron beam energy for the National Synchrotron Light Source II (NSLS-II) ring, only superconducting wigglers (SCW) producing greater than 4T peak field can cover the photon energy range of 20 keV and 200 keV with sufficient number of photons. The High energy Engineering X-ray (HEX) Diffraction beamline, which is primarily funded by the New York State Energy Research and Development Authority (NYSERDA) and NSLS-II, will be equipped with a 1.2m-long SCW with 70 mm period length and 4.3 T on-axis field. This SCW is free from the use of liquid Helium and is cooled only with cryo-coolers. The Electron Beam Chamber (EBC) with vertical aperture of 8 mm is made from 316LN stainless steel and copper plating is applied both surface and +-12.5mm wide from the center in the inner surface. The expected heat load from the electron beam of the NSLS-II ring is estimated to be 10 W/m. Here, we describe the design principles and engineering challenges for the device.

36 MATERIALS SCIENCE↗

Ultrafast optical modulation of vibrational strong coupling in ReCl(CO) 3 (2,2-bipyridine)

Polaritons – hybrid light-matter states formed from the strong coupling of a bright molecular transition with a confined photonic mode – may offer new opportunities for optical control of molecular behavior. Vibrational strong coupling (VSC) has been reported to impact ground-state chemical reactivity, but its influence on electronic excited-state dynamics remains unexplored. Here, we take a first step towards excited-state VSC by demonstrating optical modulation of the ReCl(CO) 3 (bpy), (bpy = 2,2-bipyridine) complex under VSC using femtosecond ultraviolet (UV)-pump/infrared (IR)-probe spectroscopy. We establish ground-state VSC of ReCl(CO) 3 (bpy) in a microfluidic Fabry-Pérot cavity equipped with indium tin oxide (ITO)-coated mirrors. ITO is effectively dichroic as it is reflective in the IR and transmissive in the UV-visible and therefore minimizes optical interference. Excitation with UV pump light drives ReCl(CO) 3 (bpy) into a manifold of electronic excited states that subsequently undergo non-radiative relaxation dynamics. We probe the transient response of the strongly-coupled system in the mid-IR, observing both Rabi contraction and cavity-filtered excited-state absorption signatures. We reconstruct the intrinsic response of intracavity molecules from the transient cavity transmission spectra to enable quantitative comparison with extracavity control experiments. We report no changes in the excited-state dynamics of ReCl(CO) 3 (bpy) under ground-state VSC. However, we do observe significant amplification of transient vibrational signals due to classical cavity-enhanced optical effects. This effort lays the groundwork to pursue direct excited-state VSC aimed at modulating photochemical reactivity.

cavity-enhanced spectroscopy↗

Electron density profile and associated fluctuation measurements using a microwave reflectometry diagnostic on Helically Symmetric eXperiment (HSX)

Abstract A dual-band frequency-modulated reflectometry is employed on the Helically Symmetric eXperiment (HSX) stellarator. This system equips a fast PIN switch to alternate the frequency source between two voltage-controlled oscillators, providing an operational frequency range from 14.5 GHz to 25.5 GHz. A monostatic antenna geometry and an ellipsoidal mirror are implemented in the vessel of HSX, where the polarization of the transmitted microwave can be switched between O- and X-mode to accommodate the magnetic field and plasma density. Although the original system was designed for density fluctuation measurement, significant efforts have been undertaken to improve the system performance and to realize the density profile inversion. Recent improvements of the system reported here include calibration of the dispersion in the transmission line, optimization of the waveform, and implementation of the Choi-Williams time–frequency distribution for spectral analysis. In this paper, we present the optimization of the reflectometry system along with first experimental measurements of the density profile and observations of fluctuations during gas puffing experiments.

Han, X. (ORCID:0000000184986433)↗

In situ high-temperature Raman spectroscopy for online EAF slag analysis

Real-time monitoring of slag chemistry is critical for optimizing Electric Arc Furnace (EAF) steelmaking operations, where dynamic variations in slag composition directly influence slag foaming, refractory degradation, and thermal efficiency. Conventional techniques such as X-ray fluorescence (XRF), Fourier-transform infrared (FTIR), and scanning electron microscopy coupled with energy-dispersive X-ray spectroscopy (SEM-EDS) are commonly used to analyze slag composition, but their offline nature and equipment constraints limit their applicability for online monitoring in harsh industrial environments. To address this challenge, we present an in situ, high-temperature analytical approach that integrates Raman spectroscopy with a custom designed fiber-optic probe for real-time slag characterization at 1550 °C. The system enables non destructive spectral acquisition from molten slags, providing molecular-level insights into silicate polymerization and iron oxidation states. Eight synthetic slag samples were evaluated, and key Raman features—such as Q n silicate units and FeO₄/FeO₆ coordination environments—were identified and quantitatively correlated with slag basicity and Fe₂O₃ content. The results demonstrate agreement between Raman spectral ratios and bulk slag chemistry, validating the method’s capability to track compositional and structural changes under molten temperature. This work establishes the feasibility of deploying fiber-optic Raman probe for online EAF slag monitoring and highlights their potential to support closed-loop control strategies, thereby enhancing process stability, refractory protection, and steel quality in industrial steelmaking applications.

47 OTHER INSTRUMENTATION↗

Commissioning of an MPGD-based Drift Chamber for Heavy-ion Tracking in FRIB's Sweeper magnet system

A newly developed drift chamber equipped with an innovative hybrid Micro-Pattern Gaseous Detector based readout was commissioned at FRIB. The detector consists of a Multi-layer Thick Gas Electron Multiplier (M-THGEM) mounted over a high-granularity, position-sensitive readout board. Denoted as the Micro-Pattern Drift Chamber (MPDC), the new device is used to provide tracking capability as part of the detectors of the Sweeper magnet system for neutron-invariant-mass spectrometry at the Facility for Rare Isotope Beams (FRIB). The localization of impinging ions in a 30 × 30 cm 2 drift area is derived by processing the charge-avalanche distribution induced on the segmented readout board. The signals induced on the readout pads are processed by a compact, multi-channel Data Acquisition System (DAQ) based on the Scalable Readout System (SRS). To facilitate synchronization with other detector systems of the Sweeper magnet system, the SRS has been configured to accept an external trigger.

Gaseous detectors↗

Valence-to-core X-ray emission spectroscopy of vanadium oxide and lithiated vanadyl phosphate materials

In this work, we report valence-to-core (VTC) X-ray emission spectroscopy (XES) measurements and theoretical calculations of the electrochemical sequence ε-VOPO 4 , ε-LiVOPO 4 , ε-Li 2 VOPO 4 and the reference oxides V 2 O 3 , VO 2 , and V 2 O 5 . In our analysis of these results, we establish a framework for interrogating chemical bonding that is generally applicable to a wide range of systems, including complex, extended inorganic compounds. While this latter regime has garnered less focused application than, e.g. , metalloenzymes in many excellent catalysis studies, we show that the technique provides high utility in materials-focused energy storage research. Here, sensitivities to the local atomic structure and hybridization schemes are discussed in detail. Similarly, the effect of lithiation on oxidation, delocalization, and shifts in ligand valence energy levels are all readily apparent in the analyzed results. Finally, the TDDFT projections clearly reveal the directional dependencies of the valence band at each of the vanadium sites. Our results demonstrate laboratory-based X-ray spectroscopy instrumentation is a viable route for attaining well-resolved VTC-XES features for inorganic compounds of 3d transition metals, even for samples of limited quantity or suffering from sensitivity to the atmosphere. The experimental results are in good agreement with results produced by real-space Green's function and time-dependent density functional theory (TDDFT) methods, respectively. Hence, we propose that VTC-XES, when equipped with appropriate theoretical support, can be a valuable complement to X-ray absorption pre-edge features for more detailed characterization of a compound's electronic structure. We expect similar analyses will find application in a broad range of materials chemistry research and provide both fundamental and applied insights.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Plutonium Dedicated Surface Probe Microscopy Capability

An atomic force microscope (AFM) equipped with gas dosing capabilities and a scanning tunneling microscope (STM) housed within a vacuum chamber with Pu sputtering capabilities and the potential for rapid heating via electron bombardment have been devised for investigations of Pu surface aging (such as oxidation, corrosion, and self-irradiation damage), reactivity, and rapid heating. These instruments are capable of probing Pu surface areas ranging from a fractions of nm2 (STM) to hundreds of μm2 (AFM) to obtain three dimensional imaging of surface microstructure and morphology, as well as mapping of the local electronic structure (i.e., the occupied and unoccupied electronic states), surface chemical, and mechanical properties. A detailed description of our surface probe microscopy (SPM) capability, specifically designed for handling of Pu coupons is given in the references. In FY20, four tasks have been undertaken: Resumed maintenance of Pu AFM and modification of STM capabilities including calibration, annual measurement of Pu surface, and implementation of additional instrumentation for rapid heating effort; Analyzed AFM FY19 gas dosing experiment data of 7 at% gallium-stabilized δ-phase Pu (δ-Pu) coupon; Determined the direction of future gas dosing experiments to investigate reversibility of surface features; and, Published a paper titled "Effects of ion sputtering on plutonium surfaces" in the Journal of Nuclear Materials.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

Toward Wireless Smart Grid Communications: An Evaluation of Protocol Latencies in an Open-Source 5G Testbed

Fifth-generation networks promise wide availability of wireless communication with inherent security features. The 5G standards also outline access for different applications requiring low latency, machine-to-machine communication, or mobile broadband. These networks can be advantageous to numerous applications that require widespread and diverse communications. One such application is found in smart grids. Smart grid networks, and Operational Technology (OT) networks in general, utilize a variety of communication protocols for low-latency control, data monitoring, and reporting at every level. Transitioning these network communications from wired Wide Area Networks (WANs) to wireless communication through 5G can provide additional benefits to their security and network configurability. However, introducing these wireless capabilities may also result in a degradation of network latency. In this paper, we propose utilizing 5G for smart grid communications, and we evaluate the latency impacts of encapsulating GOOSE, Modbus, and DNP3 for transmission over a 5G network. The OpenAirInterface open-source library is utilized to deploy an in-lab 5G Core Network and gNB for testing with off-the-shelf User Equipment (UE). This creates an effective 5G test platform for experimenting with different OT protocols such as GOOSE. The results are validated by measuring two different Intelligent Electronic Devices’ contact closure times for each network configuration. These tests are also conducted for varying packet sizes in order to isolate different sources of network latency. Our study outlines the latency impact of communication over 5G for time-critical and non-critical applications regarding their transition toward private 5G-based OT network implementations. The conducted experiments illustrate that in the case of GOOSE packets, simple encapsulation may exceed the protocol’s time-critical nature, and, therefore, additional measures must be taken to ensure a viable transition of GOOSE to 5G services. However, non-critical applications are shown to be viable for migration to 5G.

42 ENGINEERING↗