Search NASASearch

SEARCH · Search NASA

Results for “Electrical properties”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

841 records · Page 9

A Sensitivity-driven Wide Area Protection (SWAP) Coordination Tool for High Penetration of Inverter-based Resources (IBR)

Traditionally, power system generation sources have been composed of synchronous generators, of which the fault current behavior is understood with minimal differences between generation size and types due to the physics of their construction. Present protection schemes and modeling methods are based upon these understood characteristics. Most renewable generation is composed of inverter-based resources (IBR), in which fault current is determined by switching control software and hardware limitations, each of which can vary between manufacturers and even between models of the same manufacturer. The resulting fault current is low in magnitude, low in negative-sequence current, unpredictable phase angles, and is a challenge to model. These characteristics also result in a challenge to traditional protection schemes and fault simulation software. To address several of these concerns, the project has the following goals: 1. Improve IBR models: Improve IBR models used in short circuit (SC) programs to accurately capture the response of IBRs at the bulk power system (BPS) level for fault and protection studies. 2. Develop automation tool: Develop an automation tool that allows engineers to identify protection coordination and sensitivity issues by performing SC and protection coordination studies in a high IBR-penetrated grid by applying variations to the IBR models, faults, contingencies, etc. 3. Develop schemes: Develop new protection mitigation solution schemes that complement the existing protection systems to ensure safe operation of the BPS with higher IBR penetration levels. The project team did not achieve this final goal, as the Department of Energy (DOE) stopped the project early due to changes in DOE funding priorities. The termination notice came at the beginning of the final project phase, while the team was identifying and beginning to investigate protection issues. It should be noted that the team discussed a 100% penetration scenario. However, this scenario would require the use of grid-forming IBR models that are not presently available. Since developing these models requires additional effort, the 100% penetration scenario was not pursued during this project. In the future, developing the methodology and models for the 100% scenario could benefit the industry.

14 SOLAR ENERGY

Utilities Perspective on Protection Challenges with High IBR Penetration

Utilities have seen rapid increase in Solar, Wind, and Battery Energy Storage Resources that interconnect to their electric system through Inverters. Inverter-Based Resources (IBRs) have fault current characteristics that are unlike the fault current response of traditional rotating-machine-based generators, which is well known and repeatable. IBR’s non-traditional fault current behavior is due to the IBR control scheme, which is configured to provide a clean AC output but also protect the inverter’s sensitive power electronics devices from damage, one source of which is overcurrent. This results in low fault current magnitude, low or no negative sequence current injection, the variability of sequence component currents, the variability of voltage with respect to current angles, and the lack of inertia. The control scheme also results in a fault current response that can vary between manufactures and between models of the same manufacturer. High penetration of IBRs can adversely affect the protection schemes applied in areas with high penetration of IBRs. With the proliferation of IBRs, utilities are finding out that conventional protection schemes are not adequately equipped to protect the electric systems. This is mainly because the existing protection elements and practices have been designed based on the fault current response of conventional rotating machines. In several cases, the available literature does not provide any clear solution for the issues when the protection scheme does not operate properly near IBRs. This presentation identifies various protection challenges due to IBRs that industry is facing, from the utility perspective. Instead of facing on one issue, we are looking broadly on all the challenges that system protection has experienced with high penetration of IBRs. Based on the IBR response from various utilities during real fault events and gathering perspective from different utility SMEs via questionnaire, the presentation summarizes on gathered data and internal experiences.

24 POWER TRANSMISSION AND DISTRIBUTION

Lunar Electrical Conductivity, Permeability and Temperature From Apollo Magnetometer Experiments

Magnetometers have been deployed at four Apollo sites on the Moon to measure remanent and induced lunar magnetic fields. Measurements from this network of instruments have been used to calculate the electrical conductivity, temperature, magnetic permeability, and iron abundance of the lunar interior. The measured lunar remanent fields range from 3 gammas (γ) minimum at the Apollo 15 site to 327 γ maximum at the Apollo 16 site. Simultaneous magnetic field and solar plasma pressure measurements show that the remanent fields at the Apollo 12 and 16 sites interact with, and are compressed by, the solar wind. Remanent fields at Apollo 12 and Apollo 16 are increased 16 γ and 32 γ, respectively, by a solar plasma bulk pressure increase of 1.5 x 10 -7 dynes/cm 2 . Global lunar fields due to eddy currents, induced in the lunar interior by magnetic transients, have been analyzed to calculate an electrical conductivity profile for the Moon. From nightside magnetometer data in the solar wind it has been found that deeper than 170 km into the Moon the conductivity rises from 3 x 10 -4 mhos/m to 10 -2 mhos/m at 1000-km depth. Recent analysis of data obtained in the geomagnetic tail, in regions free of complicating plasma effects, yields results consistent with nightside values. Conductivity profiles have been used to calculate the lunar temperature for an assumed lunar material of olivine. In the outer layer (~ 170 km thick) the temperature rises to 110° C, after which it gradually increases with depth to 1500° C at a depth of ~ 1000 km. Simultaneous measurements by magnetometers on the lunar surface and in orbit around the moon are used to construct a whole-moon hysteresis curve, from which the global lunar magnetic permeability is determined to be μ = 1.012 ± 0.006. The corresponding global induced dipole moment is 2 x 10 18 gauss-cm 3 for typical inducing fields of 10 -4 gauss in the lunar environment. Lunar free iron abundance corresponding to the global permeability is determined to be 2.5 ± 2.0 wt. %. Total iron abundance (sum of iron in the ferromagnetic and paramagnetic states) is calculated for two assumed compositional models of the lunar interior. For a free iron/orthopyroxene lunar composition the total iron content is calculated to be 12.8 ± 1.0 wt. %; for a free iron/olivine composition, total iron content is 5.5 ± 1.2 wt. %. Other lunar models with an iron core and with a shallow iron-rich layer are also discussed in light of the measured global lunar permeability. Velocities and thicknesses of the Earth's magnetopause and bow shock have been estimated from simultaneous magnetometer measurements. Average speeds are determined to be about 50 km/s for the magnetopause and 70 km/s for the bow shock, although there are large variations in the measurement for any particular boundary crossing. Corresponding measured boundary thicknesses average about 2300 km for the magnetopause and 1400 km for the bow shock.

P Dyal

Hazard and risk analysis framework for nuclear power plant–based integrated energy systems

Employing integrated energy systems (IESs) with nuclear power plants (NPPs) can improve NPP utilization by leveraging dedicated thermal and electric power delivery, but it may also increase operational safety risks. This paper presents a framework to identify and quantify hazards and risks for such IESs. The framework combines accidentology to review past industrial accidents with failure modes and effects analysis (FMEA) to identify potential future incidents. Hydrogen explosion and toxic chemical release hazards are of particular concern. Explosion consequences are quantified using the Bauwens-Dorofeev (Bauwens) and trinitrotoluene equivalent mass (TNT-EM) methods, while chemical release consequences are computed using the Gaussian atmospheric dispersion method. Operational disturbances from direct electrical and thermal integration that may affect NPP safety are modeled using probabilistic risk analysis (PRA). Hazards and risks are then evaluated for regulatory compliance. The framework is applied to IESs comprising pressurized or boiling water reactors supplying three levels of thermal and electrical power to industrial customers. Case studies include high-temperature steam electrolysis hydrogen plants of varying capacities and a synthetic fuel production plant. Sensitivity analysis examines piping component failures in the PRA model as a precursor to cost estimation for thermal extraction line design. Additionally, Fussel-Vessely (FV) and risk increase importance (RII) measures identify risk-informed design improvements for the thermal extraction system. FMEA highlights hazards such as loss of offsite power, prompt loss of electrical load, loss of thermal output, and immediate steam diversion, in addition to hydrogen explosions and toxic chemical releases. Both Bauwens and TNT-EM methods suggest maintaining several hundred meters of separation between the NPP and hydrogen facility to mitigate explosion risks. PRA results show a maximum initiating event frequency increase of 1.15% and an overall risk increase of 0.28%. Importance measure analysis identifies upstream pipe leak isolation components as critical. Evaluating the results against safety regulations, it is concluded that hazards and risks can be managed to comply with regulations through risk-informed thermal and electrical connection designs, component selection, maintenance programs, and safe separation distances between NPPs and integrated industrial facilities.

08 - HYDROGEN

Interface Evolutionand Long-Term Performance of NegativeCarbon Fiber Structural Electrodes

Abstract Laminated structural batteries present a transformative solution to reducing weight constraints in electric vehicles. These structural batteries are based on a multifunctional material that incorporates an energy storage function within a carbon fiber-reinforced polymer. Despite the potential of this technology, the intricate morphology of fiber–matrix or electrode–electrolyte interfaces and the impact of long-term cycling at low current rates (C-rates) on these interfaces remain insufficiently understood. This study addresses these critical knowledge gaps by examining the influence of matrix composition on the long-term electrochemical performance of structural battery electrodes and exploring advanced techniques to investigate carbon fiber–matrix interfaces. Localized imaging and X-ray scattering techniques were used to characterize morphological changes at the electrode–electrolyte interfaces by analyzing negative structural electrodes. The findings revealed that the matrix composition influences long-term electrochemical behavior and fiber–matrix interface formation. While the intrinsic properties of carbon fibers largely remain unaffected by long-term cycling, cycling promotes debonding at fiber–matrix interfaces. Nonetheless, residual regions of adhesion persist, underscoring the potential for preserving multifunctionality even under prolonged cycling conditions. These insights advance the understanding of interface dynamics, which is critical for optimizing structural battery technologies.

Chemistry

Analysis and Overview of Hybrid Wired and Wireless Bi-Directional EV Charger Systems

Here, this paper analyzes and overviews hybrid wired and wireless bi-directional Electric Vehicle (EV) charging systems with a primary focus on resonant compensation methods that enable a unified power conversion architecture. Four compensation configurations based on series–series and LCC–LCC resonant networks are systematically evaluated for both wired transformer-based and wireless coupler-based operation. The analysis examines how coupling conditions, resonant component selection, and auxiliary compensation tuning influence voltage gain characteristics, resonant tank current magnitude and phase, and operating frequency requirements. Normalized frequency-domain results are presented to directly compare reactive current behavior and voltage regulation capability under wired and wireless operating conditions. A 60 kW bi-directional charger case study is used to demonstrate the feasibility of retaining a common hardware platform while accommodating distinct coupling scenarios through compensation tuning rather than structural modification. The presented results provide design-oriented insights into resonant network selection and compensation strategies for scalable and flexible hybrid EV charging systems.

Hybrid

Effect of Thermomechanical Processing on the Microstructure, Properties, and Work Behavior of a Ti50.5 Ni29.5 Pt20 High-Temperature Shape Memory Alloy

TiNiPt shape memory alloys are particularly promising for use as solid state actuators in environments up to 300 °C, due to a reasonable balance of proper ties, including acceptable work output. However, one of the challenges to commercializing a viable high-temperature shape memory alloy (HTSMA) is to establish the appropriate primary and secondary processing techniques for fabrication of the material in a required product form such as rod and wire. Consequently, a Ti 50.5 Ni 29.5 Pt 20 alloy was processed using several techniques including single- pass high-temperature extrusion, multiple-pass high-temperature extrusion, and cold drawing to produce bar stock, thin rod, and fine wire, respectively. The effects of heat treatment on the hardness, grain size, room temperature tensile properties, and transformation temperatures of hot- and cold-worked material were examined. Basic tensile properties as a function of temperature and the strain-temperature response of the alloy under constant load, for the determination of work output, were also investigated for various forms of the Ti 50.5 Ni 29.5 Pt 20 alloy, including fine wire.

Grain Size

Dynamic Analysis of the STARC-ABL Propulsion System

In the pursuit of Electrified Aircraft Propulsion (EAP), much of the attention is on the development of hybrid electric concept vehicles and their propulsion systems from a steady state performance perspective. While it is steady-state performance that largely determines the efficiency of civil air transports, engine operability and transient performance define constraints for the steady state design that impact efficiency and system viability. Neglecting dynamics and control technologies can result in an over-designed, sub optimal propulsion system or a concept that is not feasible. Thus, dynamic system studies were conducted on the propulsion system of the conceptual aircraft design known as the Single-aisle Turboelectric AiRCraft with Aft Boundary Layer propulsor (STARC-ABL). This paper describes the development of a controller to verify the baseline concept's feasibility from an operability perspective. Further, studies were conducted to identify excessive stability margin in the baseline design that could be traded for potential benefits in efficiency through an engine re design. This study revealed the potential to reduce the high pressure compressor (HPC) stall margin by 3%. Finally, a study was conducted to investigate the potential benefit of adding energy storage to the STARC-ABL concept that further improves operability and enables more gains in engine efficiency and performance. The energy storage provided an additional 0.5% stall margin can be removed from the HPC.

hybrid electric propulsion

Thermal Analysis on Large Format Lithium-Ion Batteries in Thermal Runaway

Lithium-ion (Li-ion) batteries can deliver electrical power across a large range of applications, and large format versions of these batteries are common in aerospace for their low mass and energy dense properties. Li-ion cells usage has increased as they are more power dense than fuel cells and have overall higher performance over lead-acid/NiCd batteries. However, Li-ion cells can experience Thermal Runaway (TR) via electro-chemical, mechanical, or thermal abuse. TR is a phenomenon where the stored energy in a cell is rapidly released along with vented gases and other effluents. A cell is generally determined to be in TR if its internal heat generation has surpassed its ability to dissipate that heat. If a Li-ion cell enters TR, propagation within the battery may occur. Propagation is the chain reaction that can occur to nearby cells due to a cell that has entered TR initially. Understanding a battery’s susceptiveness to propagation is necessary to evaluate risks associated with TR phenomenon. To determine if a battery is designed in a sufficient manner to prevent battery propagation if single cell TR occurs, testing and thermal analysis of the battery must be conducted. The presentation for TFAWS 2026 will cover considerations for battery TR thermal analysis, such as: testing methods, influences on the cells, failure mechanisms, and TR parameters. This presentation will include a walkthrough of an example battery TR thermal analysis, and the results thereof.

Lithium Ion Batteries

Polymer connectivity governs electrophotocatalytic activity in the solid state

The reductive functionalization of inert substrates such as chloroarenes is a critical yet challenging transformation relevant to both environmental remediation and organic synthesis. Combining electricity and light is an emerging strategy to access the deeply reducing potentials required for single electron transfer to chloroarenes, yet this approach is limited by poor stability and mechanistic ambiguity. Here, in this work, we demonstrate heterogeneous electrophotocatalysis using redox-active rylene diimide polymers for the reduction of chloroarenes. We find that the electrophotocatalytic activity varies dramatically as a function of the rylene diimide and the redox-inactive polymer backbone. In particular, a flexible, non-conjugated perylenediimide polymer outperforms all other tested electrophotocatalysts. Transient absorption spectroscopy reveals that precomplexation between the doubly reduced perylenediimide and the haloarene substrate is key to productive catalysis. Overall, this work highlights heterogeneous electrophotocatalysis using insoluble redox-active organic materials and provides critical structure–property insights into solid-state electrophotocatalytic activity, informing the development of next-generation materials for sustainable synthesis.

electrocatalysis

A Missed Thrust Framework for Low-Thrust Spiral Trajectories to the NRHO

A framework is developed by which end-to-end optimization of many-revolution low-thrust spiral trajectories can be completed in the presence of missed thrust events. This framework is applied to the Lunar Transit trajectory by which the initial capability of NASA’s Gateway lunar space station will be delivered to a Near Rectilinear Halo Orbit. This low-thrust mission consists of three subphases, each designed according to the specific objectives and dynamical regimes encountered as the mission progresses from a medium Earth insertion orbit to cislunar space. The presented framework accounts for the unique considerations demanded by each mission phase and incorporates appropriate capabilities into a novel mission analysis tool. This methodology enables large scale and reliable analyses of missed thrust events across the end-to-end Lunar Transit to verify the robustness of flight trajectories across the full range of considered launch dates.

missed thrust