Search NASA⌕ Search

SEARCH · Search NASA

Results for “Failure Rate”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 163 records · Page 9

Scalable Failure Masking for Stencil Computations using Ghost Region Expansion and Cell to Rank Remapping

In order to achieve exascale systems, application resilience needs to be addressed. Some programming models, such as task-DAG (directed acyclic graphs) architectures, currently embed resilience features whereas traditional SPMD (single program, multiple data) and message-passing models do not. Since a large part of the community's code base follows the latter models, it is still required to take advantage of application characteristics to minimize the overheads of fault tolerance. To that end, this paper explores how recovering from hard process/node failures in a local manner is a natural approach for certain applications to obtain resilience at lower costs in faulty environments. In particular, this paper targets enabling online, semitransparent local recovery for stencil computations on current leadership-class systems as well as presents programming support and scalable runtime mechanisms. Also described and demonstrated in this paper is the effect of failure masking, which allows the effective reduction of impact on total time to solution due to multiple failures. Furthermore, we discuss, implement, and evaluate ghost region expansion and cell-to-rank remapping to increase the probability of failure masking. To conclude, this paper shows the integration of all aforementioned mechanisms with the S3D combustion simulation through an experimental demonstration (using the Titan system) of the ability to tolerate high failure rates (i.e., node failures every five seconds) with low overhead while sustaining performance at large scales. In addition, this demonstration also displays the failure masking probability increase resulting from the combination of both ghost region expansion and cell-to-rank remapping.

97 MATHEMATICS AND COMPUTING↗

Reliability measurement during software development

Measurement of software reliability was carried out during the development of data base software for a multi-sensor tracking system. Every run made during this project was scored as success or failure, and supporting data were collected on forms for further analysis. The failure ratio (number of failures per calendar interval divided by total number of runs) and failure rate (number of failures divided by CPU time for the interval) were found to be consistent measures, on a month-to-month basis as well as from module to module, and therefore considered valid indicators of reliability in this environment. Trend lines could be established from these measurements that provide good visualization of the progress on the job as a whole as well as on individual modules. Over one-half of the observed failures were due to factors associated with the specific run submission rather than with the code proper.

Hecht, H.↗

JANTX1N2970B zener diode

Report evaluates effects of power and temperature overstress on General Semi-conductor and Siemens devices. Excessive failure rates limited testing. Failure modes are described.

Source record↗

Data Applicability of Heritage and New Hardware For Launch Vehicle Reliability Models

Bayesian reliability requires the development of a prior distribution to represent degree of belief about the value of a parameter (such as a component's failure rate) before system specific data become available from testing or operations. Generic failure data are often provided in reliability databases as point estimates (mean or median). A component's failure rate is considered a random variable where all possible values are represented by a probability distribution. The applicability of the generic data source is a significant source of uncertainty that affects the spread of the distribution. This presentation discusses heuristic guidelines for quantifying uncertainty due to generic data applicability when developing prior distributions mainly from reliability predictions.

Al Hassan, Mohammad↗

A New Class of Risk-Importance Measures to Support Reactor Aging Management and the Prioritization of Materials Degradation Research

As the US fleet of light water reactors ages, the risks of operation might be expected to increase. Although probabilistic risk assessment has proven a critical resource in risk-informed regulatory decision-making, limitations in current methods and models have constrained their prospective value in reactor aging management. These limitations stem principally from the use of static component failure rate models (which do not allow the impact of component aging on failure rates to be represented) and a very limited treatment of passive components (which would be expected to have an increasingly significant risk contribution in an aging system). Yet, a PRA captures a substantial knowledge base that could be of significant value in addressing plant aging. In this paper we will describe a methodology and a new class of risk importance measures that allow the use of an existing PRA model to support the management of plant aging, the prioritization of improvements to non-destructive examination and monitoring techniques, and the establishment of research emphases in materials science. This methodology makes use of data resources generated under the USNRC Proactive Management of Materials Degradation program which addresses the anticipated effects of numerous aging degradation mechanisms on a wide variety of component types.

22 GENERAL STUDIES OF NUCLEAR REACTORS↗

Remote Structural Health Monitoring and Advanced Prognostics of Wind Turbines

The prospect of substantial investment in wind energy generation represents a significant capital investment strategy. In order to maximize the life-cycle of wind turbines, associated rotors, gears, and structural towers, a capability to detect and predict (prognostics) the onset of mechanical faults at a sufficiently early stage for maintenance actions to be planned would significantly reduce both maintenance and operational costs. Advancement towards this effort has been made through the development of anomaly detection, fault detection and fault diagnosis routines to identify selected fault modes of a wind turbine based on available sensor data preceding an unscheduled emergency shutdown. The anomaly detection approach employs spectral techniques to find an approximation of the data using a combination of attributes that capture the bulk of variability in the data. Fault detection and diagnosis (FDD) is performed using a neural network-based classifier trained from baseline and fault data recorded during known failure conditions. The approach has been evaluated for known baseline conditions and three selected failure modes: pitch rate failure, low oil pressure failure and a gearbox gear-tooth failure. Experimental results demonstrate the approach can distinguish between these failure modes and normal baseline behavior within a specified statistical accuracy.

17 WIND ENERGY↗

Gamma Knife Stereotactic Radiosurgery as Salvage Therapy After Failure of Whole-Brain Radiotherapy in Patients With Small-Cell Lung Cancer

Purpose: Radiosurgery has been successfully used in selected cases to avoid repeat whole-brain irradiation (WBI) in patients with multiple brain metastases of most solid tumor histological findings. Few data are available for the use of radiosurgery for small-cell lung cancer (SCLC). Methods and Materials: Between November 1999 and June 2009, 51 patients with SCLC and previous WBI and new brain metastases were treated with GammaKnife stereotactic radiosurgery (GKSRS). A median dose of 18 Gy (range, 10-24 Gy) was prescribed to the margin of each metastasis. Patients were followed with serial imaging. Patient electronic records were reviewed to determine disease-related factors and clinical outcomes after GKSRS. Local and distant brain failure rates, overall survival, and likelihood of neurologic death were determined based on imaging results. The Kaplan-Meier method was used to determine survival and local and distant brain control. Cox proportional hazard regression was performed to determine strength of association between disease-related factors and survival. Results: Median survival time for the entire cohort was 5.9 months. Local control rates at 1 and 2 years were 57% and 34%, respectively. Distant brain failure rates at 1 and 2 years were 58% and 75%, respectively. Fifty-three percent of patients ultimately died of neurologic death. On multivariate analysis, patients with stable (hazard ratio [HR] = 2.89) or progressive (HR = 6.98) extracranial disease (ECD) had worse overall survival than patients without evidence of ECD (p = 0.00002). Concurrent chemotherapy improved local control (HR = 89; p = 0.006). Conclusions: GKSRS represents a feasible salvage option in patients with SCLC and brain metastases for whom previous WBI has failed. The status of patients' ECD is a dominant factor predictive of overall survival. Local control may be inferior to that seen with other cancer histological results, although the use of concurrent chemotherapy may help to improve this.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

A Phase II Trial of Brachytherapy Alone After Lumpectomy for Select Breast Cancer: Tumor Control and Survival Outcomes of RTOG 95-17

Purpose: Radiation Therapy Oncology Group 95-17 is a prospective Phase II cooperative group trial of accelerated partial breast irradiation (APBI) alone using multicatheter brachytherapy after lumpectomy in select early-stage breast cancers. Tumor control and survival outcomes are reported. Methods and Materials: Eligibility criteria included Stage I/II breast carcinoma confirmed to be <3 cm, unifocal, invasive nonlobular histology with zero to three positive axillary nodes without extracapsular extension. APBI treatment was delivered with either low-dose-rate (LDR) (45 Gy in 3.5-5 days) or high-dose-rate (HDR) brachytherapy (34 Gy in 10 twice-daily fractions over 5 days). End points evaluated included in-breast control, regional control, mastectomy-free rate, mastectomy-free survival, disease-free survival, and overall survival. The study was designed to analyze the HDR and LDR groups separately and without comparison. Results: Between 1997 and 2000, 100 patients were accrued and 99 were eligible; 66 treated with HDR brachytherapy and 33 treated with LDR brachytherapy. Eighty-seven patients had T1 lesions and 12 had T2 lesions. Seventy-nine were pathologically N0 and 20 were N1. Median follow-up in the HDR group is 6.14 years with the 5-year estimates of in-breast, regional, and contralateral failure rates of 3%, 5%, and 2%, respectively. The LDR group experienced similar results with a median follow-up of 6.22 years. The 5-year estimates of in-breast, regional, and contralateral failure rates of 6%, 0%, and 6%, respectively. Conclusion: Patients treated with multicatheter partial breast brachytherapy in this trial experienced excellent in-breast control rates and overall outcome that compare with reports from APBI studies with similar extended follow-up.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Evaluation of the accuracy of 3DVH software estimates of dose to virtual ion chamber and film in composite IMRT QA

Purpose: A novel patient-specific intensity modulated radiation therapy (IMRT) QA system, 3DVH software and mapcheck 2, purports to be able to use diode array-measured beam doses and the patient's DICOM RT plan, structure set, and dose files to predict the delivered 3D dose distribution in the patient for comparison to the treatment planning system (TPS) calculated doses. In this study, the composite dose to an ion chamber and film in phantom predicted by the 3DVH and mapcheck 2 system is compared to the actual measured chamber and film doses. If validated in this context, then 3DVH can be used to perform an equivalent dose analysis as that obtained with film dosimetry and ion chamber-based composite IMRT QA. This is important for those losing their ability to perform film dosimetry for true composite IMRT QA and provides a measure of confidence in the accuracy of 3DVH 3D dose calculations which may replace phantom-based IMRT QA. Methods: The dosimetric results from 15 consecutive patient-specific IMRT QA tests performed by composite field irradiation of ion chamber and EDR2 film in a solid water phantom were compared to the predicted doses for those virtual detectors based on the calculated 3D dose by the 3DVH software using mapcheck 2 measured doses of each beam within each plan. For each of the 15 cases, immediately after performing the ion chamber plus film measurements, the mapcheck 2 was used to measure the dose for each beam of the plan. The dose to the volume of the virtual ion chamber and the dose distribution in the plane of the virtual film calculated by the 3DVH software was extracted. The ratio of the measured to 3DVH or eclipse-predicted ion chamber doses was calculated. The same plane in the phantom measured using film and calculated with eclipse was exported from 3DVH and the 2D gamma metric was used to compare the relationship between the film doses and the eclipse or 3DVH predicted planar doses. Also, the 3D gamma value was calculated in the 3DVH software which compares the eclipse dose to the 3DVH predicted dose distribution. For the 2D and 3D gamma metrics, 2% dose and 2 mm distance to agreement (DTA) were used. In addition, a simple dose difference was performed using either a 2% or 3% dose difference tolerance. Results: The mean ratio {+-} standard deviation of the measured vs 3DVH or vs eclipse-predicted dose to the ion chamber was 1.013 {+-} 0.015 and 1.003 {+-} 0.012, respectively. For 3DVH vs eclipse, the mean percentage of pixels failing the 3D gamma metric was 1.2% {+-} 1.4% while the failure rate for the 2D gamma metric was 1.1% {+-} 0.9%. When either 3DVH or eclipse was compared to EDR2 film, the gamma failure rate was 2.3% {+-} 2.0% and 1.6% {+-} 1.7%, respectively. Mean dose difference failures were 9%-27% {+-} 5%-15% for 2 or 3% dose difference tolerances, depending on the combination of systems tested. No statistically significant differences were found for any of the planar dosimetric comparisons. Conclusions: 3DVH + mapcheck 2 predicts the same absolute dose, the percent of pixels failing the gamma metric, and the percent of pixels failing 2% or 3% dose difference tolerance tests as one would have obtained had one made measurements in solid water phantom using an ion chamber and coronal film instead of a diode array. This is also a necessary although not sufficient condition for validation of the accuracy of 3DVH predictions of the 3D dose using beam-by-beam measurements.

61 RADIATION PROTECTION AND DOSIMETRY↗

redMaPPer II: X-ray and SZ performance benchmarks for the SDSS catalog

We evaluate the performance of the Sloan Digital Sky Survey (SDSS) DR8 redMaPPer photometric cluster catalog by comparing it to overlapping X-ray- and Sunyaev-Zeldovich (SZ)-selected catalogs from the literature. We confirm that the redMaPPer photometric redshifts are nearly unbiased ((Δz) ≤ 0.005), have low scatter (σ {sub z} ≈ 0.006-0.02, depending on redshift), and have a low catastrophic failure rate (≈1%). Both the T{sub X} -λ and M {sub gas}-λ scaling relations are consistent with a mass scatter of σ{sub ln} {sub M|λ} ≈ 25%, albeit with a ≈1% outlier rate due to projection effects (λ is the cluster richness estimated employed by redMaPPer). This failure rate is somewhat lower than that expected for the full cluster sample but is consistent with the additional selection effects introduced by our reliance on X-ray and SZ selected reference cluster samples. Where the redMaPPer DR8 catalog is volume-limited (z ≤ 0.35), the catalog is 100% complete above T{sub X} ≳ 3.5 keV, and L{sub X} ≳ 2 × 10{sup 44} erg s{sup –1}, decreasing to 90% completeness at L{sub X} ≈ 10{sup 43} erg s{sup –1}. All rich (λ ≳ 100), low-redshift (z ≲ 0.25) redMaPPer clusters are X-ray-detected in the ROSAT All Sky Survey, and 86% of the clusters are correctly centered. Compared to other SDSS photometric cluster catalogs, redMaPPer has the highest completeness and purity, and the best photometric redshift performance, though some algorithms do achieve comparable performance to redMaPPer in subsets of the above categories and/or in limited redshift ranges. The redMaPPer richness is clearly the one that best correlates with X-ray temperature and gas mass. Most algorithms (including redMaPPer) have very similar centering performance as tested by comparing against X-ray centers, with only one exception which performs worse.

79 ASTRONOMY AND ASTROPHYSICS↗

Enhanced Component Performance Study: Air-Operated Valves 1998–2020

This report presents an enhanced performance evaluation of air-operated valves (AOVs) at U.S. commercial nuclear power plants. The data used in this study are based on the operating experience failure reports from calendar year 1998 through 2020 as reported in the Institute of Nuclear Power Operations (INPO) Industry Reporting and Information System (IRIS). The AOV failure modes considered are failure-to-open/close (FTOC), failure to operate or control (FTOP), and spurious operation (SO). The component reliability estimates and the reliability data are trended for the most recent 10-year period while yearly estimates for reliability are provided for the entire study period. The following trends were identified for the most recent 10-year period: o Extremely statistically significant increasing trend for the frequency of FTOC demands (demands per reactor year) for low-demand (= 20 demands per year) AOVs o Extremely statistically significant increasing trend for the frequency of FTOC demands for high-demand (> 20 demands per year) AOVs o Highly statistically significant decreasing trend for the failure rate of FTOP for low-demand AOVs o Highly statistically significant decreasing trend for the frequency of FTOP events (failures per reactor year) for low-demand AOVs o Statistically significant decreasing trend for the failure rate of SO for low-demand AOVs o Statistically significant decreasing trend for the frequency of SO events (failures per reactor year) for low-demand AOVs.

99 GENERAL AND MISCELLANEOUS↗

Orbital performance of communication satellite microwave power amplifiers (MPAs)

This paper presents background data on the performance of microwave power amplifiers (MPAs) used as transmitters in currently operating commercial communication satellites. Specifically aspects of two competing MPA types are discussed. These are well known TWTA (travelling wave tube amplifier) and the SSPA (solid state power amplifier). Extensive in-orbit data has been collected from over 2000 MPAs in 1991 and 1993. The study in 1991 invovlved 75 S/C (spacecraft) covering 463 S/C years. The 1993 'second-look' study encompassed a slightly different population of 72 S/C with 497 S/C years of operation. A surprising result of both studies was that SSPAs, although quite reliable, did not achieve the reliability of TWTAs were one-third more reliable in the 1993 study. This was at C-band with comparable power amplifiers, e.g. 6-16W of RF output power and similar gains. Data at K(sub u)-band is for TWTAs only since there are no SSPAs in the current S/C inventory. The other complementary result was that the projected failure rates used as S/C payload design guidelines were, on average, somewhat higher for TWTAs than the actual failure rates uncovered by this study. SSPA rates were as projected.

Strauss, R.↗

Survey on Failure Modes and Failure Mechanisms in Digital Components and Systems

This paper presents the preliminary results of a survey on the operating experience of a broad range of digital components and systems deployed in various industries. The primary objective of this survey is to identify principal modes and mechanisms of failure in field-deployed digital systems. Earlier works have sought to determine the failure rates of various classes of digital devices with the intent to integrate this information into the risk analysis calculations though still immature for such systems. Failure rates of individual components or systems are not taken into account in this evaluation; only failure modes and their respective probabilistic distribution are considered. Preliminary results from two data sources, SPIDR and FARADIP, are presented.

42 ENGINEERING↗

Neutron-induced electronic failures around a high-energy linear accelerator

Purpose: After a new in-vault CT-on-rails system repeatedly malfunctioned following use of a high-energy radiotherapy beam, we investigated the presence and impact of neutron radiation on this electronic system, as well as neutron shielding options. Methods: We first determined the CT scanner's failure rate as a function of the number of 18 MV monitor units (MUs) delivered. We then re-examined the failure rate with both 2.7-cm-thick and 7.6-cm-thick borated polyethylene (BPE) covering the linac head for neutron shielding. To further examine shielding options, as well as to explore which neutrons were relevant to the scanner failure, Monte Carlo simulations were used to calculate the neutron fluence and spectrum in the bore of the CT scanner. Simulations included BPE covering the CT scanner itself as well as covering the linac head. Results: We found that the CT scanner had a 57% chance of failure after the delivery of 200 MUs. While the addition of neutron shielding to the accelerator head reduced this risk of failure, the benefit was minimal and even 7.6 cm of BPE was still associated with a 29% chance of failure after the delivery of 200 MU. This shielding benefit was achieved regardless of whether the linac head or CT scanner was shielded. Additionally, it was determined that fast neutrons were primarily responsible for the electronic failures. Conclusions: As illustrated by the CT-on-rails system in the current study, physicists should be aware that electronic systems may be highly sensitive to neutron radiation. Medical physicists should therefore monitor electronic systems that have not been evaluated for potential neutron sensitivity. This is particularly relevant as electronics are increasingly common in the therapy vault and newer electronic systems may exhibit increased sensitivity.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Rare events and Griffiths phases in topological quantum error correction

The performance of quantum error correcting (QEC) codes is often studied under the assumption of spatiotemporally uniform error rates. On the other hand, experimental implementations almost always produce heterogeneous error rates, in either space or time, as a result of effects such as imperfect fabrication and/or cosmic rays. It is therefore important to understand if and how their presence can affect the performance of QEC in qualitative ways. Here, in this work, we study the effects of nonuniform error rates in the representative examples of the 1D repetition code and the 2D toric code, focusing on when they have extended spatiotemporal correlations; these may arise, for instance, from rare events (such as cosmic rays) that temporarily elevate error rates over the entire code patch. These effects can be described in the corresponding statistical mechanics models for decoding, where long-range correlations in the error rates lead to extended rare regions of weaker coupling. For the 1D repetition code where the rare regions are linear, we find two distinct decodable phases: a conventional ordered phase in which logical failure rates decay exponentially with the code distance, and a rare-region dominated Griffiths phase in which failure rates are parametrically larger and decay as a stretched exponential. In particular, the latter phase is present when the error rates in the rare regions are above the bulk threshold. For the 2D toric code where the rare regions are planar, we find no decodable Griffiths phase: rare events which boost error rates above the bulk threshold lead to an asymptotic loss of threshold and failure to decode. Unpacking the failure mechanism implies that techniques for suppressing extended sequences of repeated rare events (which, without intervention, will be statistically present with high probability) will be crucial for QEC with the toric code.

classical statistical mechanics↗

Air Corrosivity in U.S. Outdoor-Air-Cooled Data Centers is Similar to That in Conventional Data Centers

There is a concern that environmental-contamination caused corrosion may negatively affect Information Technology (IT) equipment reliability. Nineteen data centers in the United States and two in India were evaluated using Corrosion Classification Coupons (CCC) to assess environmental air quality as it may relate IT equipment reliability. The data centers were of two basic types: closed and outside-air cooled. A closed data center provides cool air to the IT equipment using air conditioning in which only a small percent age of the recirculation air is make-up air continuously supplied from outside to meet human health requirements. An outside-air cooled data center uses outside air directly as the primary source for IT equipment cooling. Corrosion measuring coupons containing copper and silver metal strips were placed in both closed and outside-air cooled data centers. The coupons were placed at each data center (closed and outside-air cooled types) with the location categorized into three groups: (1) Outside - coupons sheltered, located near or at the supply air inlet, but located before any filtering, (2) Supply - starting just after initial air filtering continuing inside the plenums and ducts feeding the data center rooms, and (3) Inside located inside the data center rooms near the IT equipment. Each coupon was exposed for thirty days and then sent to a laboratory for a corrosion rate measurement analysis. The goal of this research was to investigate whether gaseous contamination is a concern for U.S. data center operators as it relates to the reliability of IT equipment. More specifically, should there be an increased concern if outside air for IT equipment cooling is used To begin to answer this question limited exploratory measurements of corrosion rates in operating data centers in various locations were undertaken. This study sought to answer the following questions: (1) What is the precision of the measurements (2) What are the approximate statistical distributions of copper and silver corrosion rates in the sampled data centers(3) To what extent are copper and silver corrosion measurements related (4) What is the relationship of corrosion rate measurements between outside-air cooled data centers compared to closed data centers (5) How do corrosivity measurements relate to IT equipment failure rates The data from our limited sample size suggests that most United States data center operators should not be concerned with environmental gaseous contamination causing high IT equipment failure rates even when using outside-air cooling. The research team recommends additional basic research on how environmental conditions, specifically gaseous contamination, affect electronic equipment reliability.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Rate based failure detection

This disclosure describes, in part, a system management component and failure detection component for use in a power grid data network to identify anomalies within the network and systematically adjust the quality of service of data published by publishers and subscribed to by subscribers within the network. In one implementation, subscribers may identify a desired data rate, a minimum acceptable data rate, desired latency, minimum acceptable latency and a priority for each subscription. The failure detection component may identify an anomaly within the network and a source of the anomaly. Based on the identified anomaly, data rates and or data paths may be adjusted in real-time to ensure that the power grid data network does not become overloaded and/or fail.

47 OTHER INSTRUMENTATION↗

Electromagnetic Detection and Real-Time DMLC Adaptation to Target Rotation During Radiotherapy

Purpose: Intrafraction rotation of more than 45 Degree-Sign and 25 Degree-Sign has been observed for lung and prostate tumors, respectively. Such rotation is not routinely adapted to during current radiotherapy, which may compromise tumor dose coverage. The aim of the study was to investigate the geometric and dosimetric performance of an electromagnetically guided real-time dynamic multileaf collimator (DMLC) tracking system to adapt to intrafractional tumor rotation. Materials/Methods: Target rotation was provided by changing the treatment couch angle. The target rotation was measured by a research Calypso system integrated with a real-time DMLC tracking system employed on a Varian linac. The geometric beam-target rotational alignment difference was measured using electronic portal images. The dosimetric accuracy was quantified using a two-dimensional ion chamber array. For each beam, the following five delivery modes were tested: 1) nonrotated target (reference); 2) fixed rotated target with tracking; 3) fixed rotated target without tracking; 4) actively rotating target with tracking; and 5) actively rotating target without tracking. Dosimetric performance of the latter four modes was measured and compared to the reference dose distribution using a 3 mm/3% {gamma}-test. Results: Geometrically, the beam-target rotational alignment difference was 0.3 Degree-Sign {+-} 0.6 Degree-Sign for fixed rotation and 0.3 Degree-Sign {+-} 1.3 Degree-Sign for active rotation. Dosimetrically, the average failure rate for the {gamma}-test for a fixed rotated target was 11% with tracking and 36% without tracking. The average failure rate for an actively rotating target was 9% with tracking and 35% without tracking. Conclusions: For the first time, real-time target rotation has been accurately detected and adapted to during radiation delivery via DMLC tracking. The beam-target rotational alignment difference was mostly within 1 Degree-Sign . Dose distributions to fixed and actively rotating targets with DMLC tracking were significantly superior to those without tracking.

62 RADIOLOGY AND NUCLEAR MEDICINE↗