Search NASA⌕ Search

SEARCH · Search NASA

Results for “Gas sensor”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 163 records · Page 9

Eliminating Signal Bias Caused by Vacuum System Backstreaming in the Diagnostic Residual Gas Analyzer of ITER

In fusion neutral gas analysis, such as with the Diagnostic Residual Gas Analyzer (DRGA) for ITER, the primary measurement range of interest comprises the low-amu species (1 to 6), especially deuterium and helium. The challenge in successfully obtaining accurate measurements is two-fold. First, the sensitivity of the method must be sufficient to resolve trace amounts accurately; typically, one percent or less. Second, the gas signal from the fusion processes must be free of bias caused by the latent presence (from system outgassing and/or vacuum backstreaming) of these gases to enable accurate interpretation of the measured signal. This latter criterion can be problematic for the lightest gases since there is a propensity for some fraction of the pumped gas load to undergo a phenomenon known as backstreaming. This behavior is manifested in pumping systems for gas properties related to relative atomic weight (lightest) and size (smallest). Backstreaming results in a significant amount of the pumped gas undertaking a reverse flow and re-entering the measurement region; thus, contaminating the forward, real-time measurement. To fully eliminate this adverse effect, a conductance-limiting device – or orifice – has been installed in the high-vacuum pumping system of the present ITER DRGA prototype. The system was already equipped with a secondary turbomolecular pump (TMP), but with limited effectiveness against backstreaming in the inter-pump volume (IPV). This orifice is placed within the suction inlet coupling of the secondary TMP, which is downstream of the IPV. Its objective is to eliminate the backstreaming phenomenon by increasing the back pressure in the IPV. However, the orifice sizing must take into consideration other factors, such as the diagnostic measurement objectives. For example, in the ITER DRGA, one of the measurement requirements is a dynamic response time of ~1s. Fortunately, an added benefit of the pumping restriction created by the orifice is that the upstream pressure increase is beneficial for the DRGA’s optical gas analysis (OGA) sensors. These sensors are attached to the IPV in the present design. The glow discharges, when used as an OGA light source, will typically have a brighter light emission with increasing plasma cell pressure. In addition to the fusion machine research sector, there are other potential applications of this pumping technique where the monitoring of lighter gas concentrations is essential, such as the photolithography process for the semiconductor fabrication of integrated circuits. This presentation will describe the vacuum system used to demonstrate a process to eliminate backstreaming as well as show test results to verify the accomplishment of this critical objective.

Marcus, Chris↗

Surface Acoustic Wave Sensors for Refrigerant Leak Detection: Compact, Inexpensive, Selective and Sensitive Sensors

Pacific Northwest National Laboratory (PNNL), in collaboration with Parker and Hannifin, is developing a compact, inexpensive, and highly sensitive and selective surface acoustic wave sensor coated with fluorophillic sorbent for detecting fluorocarbon leaks from HVAC systems. Having a highly effective sorbent sensitive to fluorocarbon refrigerant vapors provides a means to develop a sensing device for leak detection. Surface acoustic wave (SAW) sensors with a gas sensing film deposited between the delay lines or on the interdigital transducer have been used to detect gas and vapor molecules in harsh environments with high sensitivity. As part of this project, PNNL screened several sorbent materials that are shown to be selective towards fluorocarbon refrigerant (R32) molecule. The identified sorbent materials were synthesized, characterized, and tested towards R32 using various spectroscopic technique. Next, the sorbent material was coated on a SAW sensor as a thin film using vapor deposition and drop coating methods. The coated thin film was further characterized and tested towards the detection of pure R32 and R32 in ambient air at room temperature to demonstrate the SAW response towards R32 in presence of other competing gases and vapors in air.

42 ENGINEERING↗

Portable chemical detection platform for on-site monitoring of odorant levels in natural gas

The adequate odorization of natural gas is critical to identify gas leaks and to reduce accidents. To ensure odorization, natural gas utility companies collect samples to be processed at core facilities or a trained human technician smells a diluted natural gas sample. In this work, we report a detection platform that addresses the lack of mobile solutions capable of providing quantitative analysis of mercaptans, a class of compounds used to odorize natural gas. Detailed description of the platform hardware and software components is provided. Designed to be portable, the platform hardware facilitates extraction of mercaptans from natural gas, separation of individual mercaptan species, and quantification of odorant concentration, with results reported at point-of-sampling. The software was developed to accommodate skilled users as well as minimally trained operators. Detection and quantification of six commonly used mercaptan compounds (ethyl mercaptan, dimethyl sulfide, n-propylmercaptan, isopropyl mercaptan, tert–butyl mercaptan, and tetrahydrothiophene) at typical odorizing concentrations of 0.1–5 ppm was performed using the device. We demonstrate the potential of this technology to ensure natural gas odorizing concentrations throughout distribution systems.

03 NATURAL GAS↗

Gas-mapping 3D imager measurement techniques and method of data processing

Measurement approaches and data analysis methods are disclosed for combining 3D topographic data with spatially-registered gas concentration data to increase the efficiency of gas monitoring and leak detection tasks. Here, the metric for efficiency is defined as reducing the measurement time required to achieve the detection, or non-detection, of a gas leak with a desired confidence level. Methods are presented for localizing and quantifying detected gas leaks. Particular attention is paid to the combination of 3D spatial data with path-integrated gas concentration measurements acquired using remote gas sensing technologies, as this data can be used to determine the path-averaged gas concentration between the sensor and points in the measurement scene. Path-averaged gas concentration data is useful for finding and quantifying localized regions of elevated (or anomalous) gas concentration making it ideal for a variety of applications including: oil and gas pipeline monitoring, facility leak and emissions monitoring, and environmental monitoring.

Thorpe, Michael↗

Functional metal–organic frameworks as effective sensors of gases and volatile compounds

Developing efficient sensor materials with superior performance for selective, fast and sensitive detection of gases and volatile organic compounds (VOCs) is essential for human health and environmental protection, through monitoring indoor and outdoor air pollutions, managing industrial processes, controlling food quality and assisting early diagnosis of diseases. Metal–organic frameworks (MOFs) are a unique type of crystalline and porous solid material constructed from metal nodes (metal ions or clusters) and functional organic ligands. They have been investigated extensively for possible use as high performance sensors for the detection of many different gases and VOCs in recent years, due to their large surface area, tunable pore size, functionalizable sites and intriguing properties, such as electrical conductivity, magnetism, ferroelectricity, luminescence and chromism. The high porosity of MOFs allows them to interact strongly with various analytes, including gases and VOCs, thus resulting in easily measurable responses to different physicochemical parameters. Although much of the recent work on MOF-based luminescent sensors have been summarized in several excellent reviews (up to 2018), a comprehensive overview of these materials for sensing gases and VOCs based on chemiresistive, magnetic, ferroelectric, and colorimertic mechanisms is missing. In this review, we highlight the most recent progress in developing MOF sensing and switching materials with an emphasis on sensing mechanisms based on electricity, magnetism, ferroelectricity and chromism. We provide a comprehensive analysis on the MOF–analyte interactions in these processes, which play a key role in the sensing performance of the MOF-based sensors and switches. We discuss in detail possible applications of MOF-based sensing and switching materials in detecting oxygen, water vapor, toxic industrial gases (such as hydrogen sulfide, ammonia, sulfur dioxide, nitrous oxide, carbon oxides and carbon disulfide) and VOCs (such as aromatic and aliphatic hydrocarbons, ketones, alcohols, aldehydes, chlorinated hydrocarbons and N,N'-dimethylformamide). Altogether, this review serves as a timely source of information and provides insight for the future development of advanced MOF materials as next-generation gas and VOC sensors.

36 MATERIALS SCIENCE↗

Novel Temperature Sensors and Wireless Telemetry for Active Condition Monitoring of Advanced Gas Turbines

The objective of the program is to develop and engine test hardware and software technologies that will enable active condition monitoring to be implemented on hot gas path turbine blades in large industrial gas turbines. The specific objectives are (1) to fabricate and install Smart Turbine Blades with thermally sprayed sensors and high temperature wireless telemetry systems in a gas turbine engine, (2) to integrate the component engine test data with remaining useful life (RUL) models and develop an approach for networking the component RUL data with Siemens' Power Diagnostics® engine monitoring system. These significant advances carried out in Phase 1 in temperature wide bandgap telemetry, along with new induced power driver and receiver geometry combined with an innovative approach to transmit digital data wirelessly will enable the opportunity to proceed with more technical innovation. The Phase 2 program focused on validation testing of sensor-wireless telemetry package in spin rig and advanced operation-based assessment (OBA) model utilizing artificial intelligence. Significant efforts were dedicated on the download of the technology onto components to be tested an actual gas turbine engine for full realization of active condition monitoring for Smart Turbine Blades.

03 NATURAL GAS↗

Fe Thin Film-Coated Optics for Corrosion Monitoring: Optical and Electrochemical Studies

Corrosion proxy materials integrated with an optical sensing platform enable a real-time optical corrosion sensor for natural gas pipelines to prevent methane leaks and catastrophic events. Effects of CO 2 , pH, and film thickness on corrosion of Fe thin films (25, 50, 100 nm) were studied using optical and electrochemical methods in 3.5%wt. NaCl solutions at 30 °C. An increase in light transmission (T%) corresponded to corrosion of Fe thin films. CO 2 accelerated corrosion of Fe thin films due to the lower pH and the promoted corrosion reactions, resulting in a faster increase of T% than without CO 2 or at higher pH. While the corrosion rate increased with increasing film thickness, electrochemical corrosion of Fe thin films was in good agreement with that of bulk carbon steel, verifying that Fe thin films can serve as a representative corrosion proxy when integrated with the optical sensing platform.

36 MATERIALS SCIENCE↗

Hydrogen Mitigation Process Testing at Nevada Solar One

The National Renewable Energy Laboratory (NREL) and Acciona Solar Power (ASP) developed and installed a process that addresses the issue of hydrogen buildup in Acciona's Nevada Solar One power plant. Our method selectively removes hydrogen from the expansion tanks of the power plant to control hydrogen levels in the circulating heat-transfer fluid (HTF). During previous work, we developed a sensor that measures hydrogen partial pressure in the expansion-tank headspace gas. We demonstrated that our sensor measures hydrogen levels over a wide range of partial pressure from 10 mbar down to 0.003 mbar. More recently, we conceived and developed an integrated process module that performs both hydrogen sensing and separating functions. The sensor/separator measures hydrogen partial pressure in the headspace gas in the same way as our original sensor design. Additionally, the integrated module separates hydrogen from the headspace gas to reduce hydrogen to the level needed to maintain the performance of receivers in the collector field. Laboratory testing at NREL showed that the sensor function had an accuracy of +/-7%, and the hydrogen extraction rate for separator function was consistent with our modeling predictions. The primary benefit of this module is its simple design, both in terms of function and incorporation into the HTF subsystem of the power plant. Most recently, NREL and ASP completed installation and initial testing of a mitigation process at ASP's Nevada Solar One power plant in Boulder City, Nevada. In this paper, we report on the completed installation, initial testing, and plans to bring the process to full automation, so that it can be operated unattended on a daily schedule.

chemical elements↗

Metal nanoparticle-decorated nanotubes for gas sensing

Disclosed herein are embodiments of compositions for gas sensing and sensors utilizing the same. In one embodiment, a composition comprises carbon nanotubes and and polymer-coated metal nanoparticles bound to the carbon nanotubes.

Iftime, Gabriel↗

Impedance-Based Detection of NO 2 Using Ni-MOF-74: Influence of Competitive Gas Adsorption

Chemically robust, low-power sensors are needed for the direct electrical detection of toxic gases. Metal–organic frameworks (MOFs) offer exceptional chemical and structural tunability to meet this challenge, though further understanding is needed regarding how coadsorbed gases influence or interfere with the electrical response. To probe the influence of competitive gases on trace NO 2 detection in a simulated flue gas stream, a combined structure–property study integrating synchrotron powder diffraction and pair distribution function analyses was undertaken, to elucidate how structural changes associated with gas binding inside Ni-MOF-74 pores correlate with the electrical response from Ni-MOF-74-based sensors. Data were evaluated for 16 gas combinations of N 2 , NO 2 , SO 2 , CO 2 , and H 2 O at 50 °C. Fourier difference maps from a rigid-body Rietveld analysis showed that additional electron density localized around the Ni-MOF-74 lattice correlated with large decreases in Ni-MOF-74 film resistance of up to a factor of 6 × 10 3 , observed only when NO 2 was present. These changes in resistance were significantly amplified by the presence of competing gases, except for CO 2 . Without NO 2 , H 2 O rapidly (<120 s) produced small (1–3×) decreases in resistance, though this effect could be differentiated from the slower adsorption of NO 2 by the evaluation of the MOF’s capacitance. Furthermore, samples exposed to H 2 O displayed a significant shift in lattice parameters toward a larger lattice and more diffuse charge density in the MOF pore. Evaluating the Ni-MOF-74 impedance in real time, NO 2 adsorption was associated with two electrically distinct processes, the faster of which was inhibited by competitive adsorption of CO 2 . Together, this work points to the unique interaction of NO 2 and other specific gases (e.g., H 2 O, SO 2 ) with the MOF’s surface, leading to orders of magnitude decrease in MOF resistance and enhanced NO2 detection. Finally, understanding and leveraging these coadsorbed gases will further improve the gas detection properties of MOF materials.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Hydrogen Mitigation Process Installation at Nevada Solar One

The National Renewable Energy Laboratory (NREL) and Acciona Solar Power (ASP) have developed and are implementing a process that addresses the issue of hydrogen buildup in parabolic trough power plants. Our method selectively removes hydrogen from the expansion tanks of the power plant to control hydrogen levels in the circulating heat-transfer fluid (HTF). During previous work, we developed a sensor that measures hydrogen partial pressure in the expansion-tank headspace gas. We demonstrated that our sensor measures hydrogen levels over a wide range of partial pressure—from 1.33 mbar down to 0.003 mbar. More recently, we conceived and developed an integrated process module that performs both hydrogen sensing and separating functions. The sensor/separator measures hydrogen partial pressure in the headspace gas in the same way as our original sensor design. Additionally, the integrated module separates hydrogen from the headspace gas to reduce hydrogen to the level needed to maintain the performance of receivers in the collector field. We demonstrated the performance of a laboratory-scale version of this module. Testing showed that the module performed as expected: the accuracy of the sensing function was ±7%, and the hydrogen extraction rate for the separating mode was consistent with our modeling predictions. The primary benefit of this module is its simple design, both in terms of function and incorporation into the HTF subsystem of the power plant. Most recently, NREL and ASP planned, specified, and designed a mitigation process that is based on the integrated module. We are currently completing installation of this process at ASP's Nevada Solar One power plant in Boulder City, Nevada, USA. The mitigation process is being installed at ground level below the HTF expansion tanks, where it draws headspace gas from the tanks, removes hydrogen, and returns the treated gas back to the tanks. In this paper, we report progress on the installation and describe some of the many design details and challenges that we addressed during the past year. We will generate initial performance data from the Nevada Solar One mitigation process in early 2020.

41 EE - Solar Energy Technologies Office (EE-4S)↗

Point Sensor Networks Struggle to Detect and Quantify Short Controlled Releases at Oil and Gas Sites

This study evaluated multiple commercially available continuous monitoring (CM) point sensor network (PSN) solutions under single-blind controlled release testing conducted at operational upstream and midstream oil and natural gas (O&G) sites. During releases, PSNs reported site-level emission rate estimates of 0 kg/h between 38 and 86% of the time. When non-zero site-level emission rate estimates were provided, no linear correlation between the release rate and the reported emission rate estimate was observed. The average, aggregated across all PSN solutions during releases, shows 5% of the mixing ratio readings at downwind sensors were greater than the site’s baseline plus two standard deviations. Four of seven total PSN solutions tested during this field campaign provided site-level emission rate estimates with the site average relative error ranging from −100% to 24% for solution D, −100% to −43% for solution E, −25% for solution F (solution F was only at one site), and −99% to 430% for solution G, with an overall average of −29% across all sites and solutions. Of all the individual site-level emission rate estimates, only 11% were within ±2.5 kg/h of the study team’s best estimate of site-level emissions at the time of the releases.

42 ENGINEERING↗

Nickel-incorporated Oxide Composites for Fiber-Optic Based Gas Sensing

Numerous high-value applications within the energy sector involve environmental conditions that are incompatible with traditional sensor technology due to degradation of electrical interconnects, packaging, or the sensors themselves. These can include chemically harsh conditions, high temperature operation, or the presence of electromagnetic interference due to high voltage. The fiber optic platform, constructed of robust, electrically insulating glass or single crystal oxides, offers a versatile and often low cost per node solution to this problem, especially with the integration of distributed sensing techniques such as optical time-domain and frequency-domain reflectometry (OTDR, OFDR). A major challenge of gas and chemical sensing on the optical fiber platform is the fabrication of robust and stable sensing materials that interact quickly and reversibly to the presence of the target analytes. In this work, we discuss the utilization of nickel-incorporated oxides on evanescent-field optical fiber sensors for gas sensing under harsh conditions relevant to multiple energy infrastructure applications. This paper will discuss a Ni/GDC (Ni / Gd-doped ceria) based sensing layer targeting conditions relevant for high-temperature (up to at least 800 oC) hydrogen sensing applications (e.g., for operation within a solid oxide fuel cell or electrolyzer). The impact of hydrogen at elevated temperatures on the optical properties of Ni/GDC will be shown and the material mechanisms for the optical response will be discussed.

gas sensors↗

Nickel-incorporated Oxide Composites for Fiber-Optic Based Gas Sensing

Numerous high-value applications within the energy sector involve environmental conditions that are incompatible with traditional sensor technology due to degradation of electrical interconnects, packaging, or the sensors themselves. These can include chemically harsh conditions, high temperature operation, or the presence of electromagnetic interference due to high voltage. The fiber optic platform, constructed of robust, electrically insulating glass or single crystal oxides, offers a versatile and often low cost per node solution to this problem, especially with the integration of distributed sensing techniques such as optical time-domain and frequency-domain reflectometry (OTDR, OFDR). A major challenge of gas and chemical sensing on the optical fiber platform is the fabrication of robust and stable sensing materials that interact quickly and reversibly to the presence of the target analytes. In this work, we discuss the utilization of nickel-incorporated oxides on evanescent-field optical fiber sensors for gas sensing under harsh conditions relevant to multiple energy infrastructure applications. This paper will discuss a Ni/GDC (Ni / Gd-doped ceria) based sensing layer targeting conditions relevant for high-temperature (up to at least 800oC) hydrogen sensing applications (e.g., for operation within a solid oxide fuel cell or electrolyzer). The impact of hydrogen at elevated temperatures on the optical properties of Ni/GDC will be shown and the material mechanisms for the optical response will be discussed.

gas sensors↗

Bubble Mass Transport Measurement in the Large-Scale Test Loops at Oak Ridge National Laboratory

Molten salts are complex fluids that incorporate multi-phase behavior depending on the chemistry and the physical properties of the entrained components. These components include the carrier salt, the actinide fuel, and fission, activation, and corrosion products, the concentrations of which depends on the burnup history of the salt. Radionuclide transport from the salt into the cover gas / off-gas system depends on volatility as predicted by thermochemistry, but data from the Molten Salt Reactor Experiment (MSRE) conducted in the late 1960s suggest that bubble formation and transport are also important. Anomalously high fractions of noble metals were found in the off-gas system and were attributed to transportation with parent salt aerosols and their association with rising noble gas bubbles. The prediction of such phenomena requires coupled neutronic, thermal hydraulic, and chemical equilibrium calculations, the framework of which is being developed within the Nuclear Energy Advanced Modeling and Simulation (NEAMS) program supported by the US Department of Energy (DOE) Office of Nuclear Energy (NE). However, separate effects tests and models of experiments using tools such as SAM and Thermochimica can guide model developers through important processes. Conversely, model development guides the choice of experiments and systems to provide data that are relevant for validation. This report describes several experiments that tracked gas transport in molten salts, ranging from small-scale systems to large-scale loops. Gas transportation in a molten salt, LiCl-KCl, has been studied using the shadowgraph technique. Sensors such as residual gas analysis, Raman spectroscopy, and laser-induced breakdown spectroscopy have been tested for off-gas measurements. These data were used to interpret how the gases move through the upstream salt / cover gas and the interface between them. Differential pressure measurements were able to detect individual gas bubbles as they popped at the liquid–gas interface. Salt aerosols were collected on a cascade impactor. Their formation was also observed directly via the shadowgraph method, and most of these aerosols were launched ballistically into the cover gas. Fine mists could also be observed. Convection currents through the salt were visualized and can be used to calculate the thermophysical properties of the salt itself. The apparatuses described in this report and in a previous work (McFarlane et al. 2023) have been commissioned and are available for use in making further measurements of salt/surrogate fission product behavior. Novel approaches using neutron imaging are planned for the study of fluoride salts, which cannot be contained in quartz, so shadowgraph visualization is not available. Bubble transport in convective flow and in a slow-moving salt column are planned. The mobile laser-induced breakdown spectroscopy (LIBS) system is available for several applications, including iodine capture in a molten hydroxide scrubber, H2 transport though molten salts to complement Raman analysis, and online tracking of salt aerosol generation, transport, and deposition. This report summarizes the findings from FY24 and the plans for FY25. The work completes milestone M2AT-24OR0702013 of the DOE-NE Advanced Reactor Technology, Molten Salt Reactor Campaign, DOE-NE-5.

22 GENERAL STUDIES OF NUCLEAR REACTORS↗

SO3/H2SO4 continuous real-time sensor demonstration at a power plant

We present results from field testing of a new, innovative sensor developed to measure SO3/H2SO4 continuously and in real time at a coal-fired power plant. The system utilizes the sensitivity, specificity, and real-time capabilities of mid-infrared (Mid-IR) laser-based sensor technology, along with a heated, close-coupled cell mounted directly to a power plant duct. Measurements were made by the laser sensor over a 2-day period and compared to results from the accepted method, EPA 8A, which requires a 30-minute collection, labor intensive processing, and off-site analysis at a lab. In contrast to the condensation method, the laser sensor continuously samples flue gas and reports measurements of the concentration of SO3/H2SO4, SO2 ever second with unattended operation. This initial demonstration proved the sensor concept and paves the way for its use for optimizing sorbent injection used to neutralize SO3/H2SO4. Optimized sorbent injection will enable significant cost savings associated with efforts to mitigate the presence and effects of SO3/H2SO4 such as “Blue Plume”, air heater fouling, and duct corrosion. In particular, the real-time, actionable information will enable better control of additive injection in flex conditions and variable fuels.

20 FOSSIL-FUELED POWER PLANTS↗

In-situ localized growth of porous metal oxide films on microheater platform for low temperature gas detection

A solid-state, low power microheater sensor platform that is configurable with selected metal oxide films for particular gas sensing applications is described. The sensor platform is configured by selecting a chemiresistive or catalytic material that is suitable for detecting a desired gas and then forming a porous nanostructured film on the designated surfaces of the microheater platform. Also described are methods for creating a highly porous, nanostructured metal oxide film in a controlled location from a liquid precursor using a localized heat source. By fast annealing deposited liquid precursors with the microheater, a highly porous, nanocrystalline metal oxide film can be generated in-situ and locally on the sensor platform.

Maboudian, Roya↗