Search NASA⌕ Search

SEARCH · Search NASA

Results for “Hybrid Renewable Energy Systems”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 163 records · Page 9

Shifts in hydropower operation to balance wind and solar will modify effects on aquatic biota

To avoid negative consequences to freshwater biota from climate change, society must complete the transition from fossil to renewable electricity sources. However, temporal patterns in hydropower generation (and flow releases that affect aquatic biota) may change with increased wind and solar penetration. We used power cost modeling to characterize current and future within-day and seasonal patterns in hydropower generation across the Eastern Interconnection in a wet and a dry year. Compared to the baseline, future hydropower generation across the grid decreased during the day and increased before dawn and after dusk. At a project level, such a pattern would suggest 'double peaking' operation (up- and down-ramping before dawn and after dusk, with lower releases midday). Variation in generation was higher in wet years than dry years, foreshadowing possible flow constraints on hydropower flexibility. At the grid scale, projected ramping rates were higher in all seasons. A review of the ecological literature suggests that these changes would shift the timing of invertebrate drift and elevate the risk of nest scouring during up-ramping and the risk of stranding or dewatering during down ramping. Thermal conditions may be moderated by increased ramping. Strategies for adapting to future shifts in the renewable portfolio range from re-regulation in reservoir cascades to providing flow refuge (structures and vegetation) below individual projects. Coordinated basin-scale operation can distribute peaking operation to maintain grid support while restricting local ramping at critical ecological times. In addition, research to design hybrid renewable systems that add battery storage is needed to understand how we can mitigate future risks to aquatic communities while promoting the use of renewable energy. This study, which is among the first to examine ecological side-effects of the shift to renewable energy in freshwater ecosystems, lays out a path toward understanding and navigating changes to flow regimes under the energy transition.

54 ENVIRONMENTAL SCIENCES↗

Multiscale Electricity Modeling for Evaluating Carbon Capture and Sequestration Technologies (Final Report)

Carbon capture and sequestration (CCS) technologies that can operate with a high degree of operating flexibility could provide necessary electric grid flexibility in a system with high shares of variable renewables. This project examines the deployment and dispatch potential of twelve unique flexible CCS (FLECCS) technologies that encompass post-combustion carbon dioxide (CO 2 ) capture designs, concepts using a storage media to enable energy arbitrage, and hybrid processes that integrate CCS with direct air capture (DAC) for flexibility with net zero or negative CO 2 emissions. FLECCS technology potential is explored with a multi-model, multi-scale framework including the Regional Energy Deployment System (ReEDS) electric sector capacity expansion model (CEM) and the PLEXOS production cost model (PCM). Innovative methods were developed to represent FLECCS technology operating modes, performance, and cost in the two models. ReEDS was then used to simulate nine scenarios for each FLECCS technology, three CO 2 emissions price futures reaching $\$$150, $\$$225, and $\$$300/tCO 2 in 2050; and three scenarios for FLECCS technology deployment favorability relative to competing technologies. For each CO 2 price and reference FLECCS favorability, the 2050 infrastructures from ReEDS model are downscaled and implemented in PLEXOS to examine hourly dispatch under detailed operational constraints that are not included in ReEDS. FLECCS technologies exhibited a wide range of deployment potential ranging from none to several hundred gigawatts of capacity, with outcomes highly sensitive to input cost and performance parameters that are inherently highly uncertain. When deployed, FLECCS tended to displace a combination of wind, solar, and natural gas-based technologies rather than supporting increased renewable deployment. As a result, CO 2 emissions reductions facilitated by FLECCS deployment tended to come with higher overall system costs and electricity prices. When economically competitive, FLECCS technologies can contribute significant flexible generation and firm capacity to the grid, but continued technology development and an expanded analytical scope are necessary to fully understand FLECCS deployment potential its impact on the electric power sector. Follow-on analysis incorporating captured CO 2 tax credit value from the Inflation Reduction Act (IRA) and other potential policy scenarios could be particularly valuable, as this policy can substantially change the relative competitiveness of FLECCS technologies.

03 NATURAL GAS↗

Wind and Solar Hybrid Power Plants for Energy Resilience

Wind-solar-storage hybrid power plants represent a significant and growing share of new proposed projects in the United States (U.S.). Their uptake is supported by increasing renewable energy market share, technical abilities for dispatch and control, and decreasing wind, solar, and battery storage costs. Simultaneously, generation and storage resources are increasingly used in distributed power systems. While concerns around the reliability of the aging, transforming U.S. electric grid are growing, diversifying energy resources through hybridization or spatial distribution provides an opportunity to enhance power system resilience compared to single-source generation. Understanding where to build hybrids for resilience value, rather than bulk power supply, has not been fully explored in previous studies. Therefore, in this study, we complete a national complementarity analysis to identify areas in the U.S. that are particularly suited for wind-solar hybrid power plant development. We show the importance of seasonal and diurnal patterns in assessing complementarity, and identify that regions in the Great Plains, Midwest, and Southeast are particularly suited for hybrid power plants. We demonstrate the resilience value of hybridization for a reference system based near Memphis, Tennessee, and show optimal sizing of wind, solar, and storage assets given 1.0 and 0.9 critical load factors. Results indicate that pairing wind and solar assets better meet constant load demand and reduce storage requirements compared to solar alone. These results enable future work integrating complementarity metrics in resilience frameworks and indicate a need for more finer resolution of local resource, demand, and hazard data.

14 SOLAR ENERGY↗

Enabling Floating Solar Photovoltaic (FPV) Deployment: Exploring the Operational Benefits of Floating Solar-Hydropower Hybrids

The Southeast (SE) Asia region is undergoing rapid energy sector transitions and exploring the potential role of renewables - including solar photovoltaics (PV) - as it becomes increasingly competitive as a result of technological advances and falling capital costs. Low-cost solar PV provides countries in the region with an option to meet increasing energy demand and diversify generation portfolios, complementing hydropower and thermal-dominant systems and strengthening energy security throughout the region. Floating solar PV (FPV) has emerged as an attractive application of solar PV that allows for systems to be floated on water bodies. Pairing FPV in hybrid systems with hydropower may also provide significant value for power systems in the region, beyond oft-cited co-benefits of stand-alone FPV. Despite growing interest in FPV systems, few applications of hybrid FPV-hydropower systems exist in SE Asia, and limited information is available about the co-benefits these systems may provide for potential adopters. This work, funded by the U.S. Agency for International Development (USAID) through the Advanced Energy Partnership for Asia, explores the value that hybrid FPV-hydropower systems may provide to the power systems of SE Asian countries. This work on the value of hybrid FPV-hydropower systems is accompanied by a recent report, Creating an Enabling Policy and Regulatory Environment for Floating Solar Photovoltaics: Review of Barriers to FPV Deployment in Southeast Asia, also focused on SE Asia.

14 SOLAR ENERGY↗

Techno-economic assessment of electricity market potential for co-located hydro-floating PV systems

Abstract—Harnessing renewable energy from diverse sources is paramount for sustainable power systems. Recently, co-located floating PV (FPV) systems present an intriguing prospect in this context. These hybrid systems, blending hydro and solar power, may offer a more consistent electricity output and potential economic advantages. Yet, assessing their actual potential requires a comprehensive techno-economic assessment. In addition, probabilistic price forecasting has recently gained attention in electricity market because decisions based on such predictions can yield significantly higher profits than those made with point forecasts alone. To this end, this paper embarks on a journey to elucidate the electricity market potential of co-located hydro-FPV systems in a probabilistic fashion to investigate the technological merits and economic viability of co-located hydro-FPV under different market structures. Our preliminary findings suggest that LCOE and payback metrics are sensitive not only to different markets but also to different solar incentives. Concurrently, we also observe that the payback period is generally faster with a production tax credit (PTC) than an investment tax credit (ITC). This assessment serves as a cornerstone for understanding the future prospects of co-located hydro-FPV systems in modern electricity markets.

13 HYDRO ENERGY↗

Integration of Heat Pumps With Solar Thermal Systems for Energy Storage

This chapter considers the combination of solar thermal systems with an energy storage device known as a Carnot Battery which charges thermal storage with a heat pump or electric heater. Integrating these systems can provide a variety of advantages, such as dispatchable renewable power generation and electricity storage services. In this chapter a variety of methods for hybridizing these systems are described, and ideal cycle analysis is used to assess their relative merits.

Carnot Battery↗

Analysis of pumped thermal energy storage using particle media integrated with concentrating solar power

Pumped Thermal Energy Storage (PTES) is an electricity storage system that converts electricity into thermal energy which is stored and later transformed back into electricity. Previous work has illustrated that particles have low capital costs and can be operated over a wide range of temperatures. PTES with particle storage achieves higher round-trip efficiency and specific power output than when molten salt thermal energy storage is used. This article explores hybrid systems that combine PTES with Concentrating Solar Power (CSP). Hybrid systems share the majority of components thereby reducing costs compared to two stand-alone devices. In addition, hybrid systems can provide multiple services (such as renewable power generation and electricity storage services). Using particle thermal storage in these hybrid concepts provides freedom in choosing the design conditions, since a wide range of operating temperatures is allowable, therefore making it possible to identify hybrid system designs that have good performance. In this article, two concepts for hybrid PTES-CSP are introduced. Thermodynamic models are developed and these are used to evaluate the performance of two hybrid systems. These models account for turbomachinery efficiency, and approach temperature and pressure loss in heat exchangers, as well as other sources of inefficiency, such as motor-generator losses, and air fan power. The “Solar Top-Up” Concept uses CSP to increase the temperature delivered by the charging heat pump. The discharging system uses a topping gas cycle and a bottoming steam cycle to fully exploit the available energy. Using solar heat to increase the maximum temperature from 750 K to 1100 K increases the round-trip efficiency from 41 % to 62 % and the specific work output from 88 kJ/kg to 301 kJ/kg. The second concept is a “Dual-Mode” device which provides both electricity storage and solar electricity generation with the same set of components. The PTES-mode and CSP-mode performance are optimized at different design values but careful parameter selection leads to good performance of both modes: one design produces PTES round-trip efficiency > 60 %, CSP heat engine efficiency > 40 %, and specific work outputs > 150 kJ/kg (for both cycles), when the particle receiver temperature is > 1200 K and maximum heat pump temperature is 1100 K.

14 SOLAR ENERGY↗

Nontechnical Barriers to Geothermal Development

Geothermal energy presents a significant opportunity for the United States (US). The US has the largest known geothermal resource in the world, with over 31 GW of conventional geothermal (i.e., hydrothermal) potential. Despite this, the development of geothermal power plants has lagged other renewable resources. Though some of the gaps stem from technical barriers numerous non-technical barriers are preventing geothermal energy from reaching its full potential. The gaps include a need to reduce the cost impacts of seismic risk, environmental risk, exploration, drilling and permitting cost risk, and reduced summer capacity on plant profitability. This report identifies pathways to overcome these barriers. We find that geothermal energy could increase its market presence by acting as a complement to lower cost renewables, providing flexible or baseload power in low carbon scenarios. We also outline several contractual and operational strategies (including the use of hybrid systems) that plant operators can pursue to improve the value of their resource, such as multi part remuneration mechanisms that guarantee revenue (e.g., availability payments or a Contract for Differences approach) or resource risk hedging approaches (e.g., shaped market products and portfolio resource approaches).

15 GEOTHERMAL ENERGY↗

Principles to adapt financing mechanisms for fully integrated hybrid energy systems

As the electricity sector evolves, and as all energy types (thermal, electric, chemical, etc.) become more coupled, there has been increased interest to develop and deploy hybrid energy systems (HES). This work focuses on fully integrated HES, where there are multiple energy sources and multiple energy products, often coupled through a storage buffer. A significant amount of the available literature on this work describes technology pathways for fully integrated HES; however, it is unclear how financial institutions should treat these systems. Fully integrated HES represent an increase in complexity from their stand-alone counterparts, but they also potentially mitigate financial risk and provide value to the energy system, which has not yet been accounted for in financing mechanisms that could help to enable such systems. This paper provides some examples of fully integrated HES and proposes principles to help adapt financing to adequately capture the value of such systems.

29 ENERGY PLANNING, POLICY, AND ECONOMY↗

A Low Voltage DC Power Electronic Hub to Support Buildings

This paper presents the communication, control, and architecture, for a low voltage (nominal 480V) hybrid AC/DC microgrid for supporting small commercial buildings with critical data center loads. The proposed system is based on a dc-power electronic hub (PEH) that seamlessly integrates renewable energy resources, energy storage, and back-up generation to support commercial building economical energy management and reliability. This PEH concept provides a parallelization of critical power to the commercial and industrial buildings leading to increased efficiency and reliability compared to traditional uninterruptable power supplies. The demonstration of the proposed PEH architecture and controls is conducted through a controller hardware in the loop validation.

Starke, Michael↗

A Hybrid Fuel Cell and Battery Storage Power Management for Grid-Interactive EV Charging Station

With the increasing adoption of renewable energy sources in grid-interactive Electric Vehicle (EV) charging stations, the role of energy storage systems has become critical. While large energy storage systems have mitigated the intermittency of renewable energy, integrating multi-source energy management with prioritized charging can further enhance the reliability of charging stations (CS). This paper presents a decentralized energy management (DEM) approach combining battery energy storage (BES) and fuel cell (FC) systems using a rule-based line resistance correction droop (LRCD) control technique. The proposed droop control dynamically adjusts the gain to balance the state-of-charge (SoC) of the BES, enhancing power support longevity and improving battery life under varying capacity conditions by reducing current stress. Additionally, the paper addresses the challenges of using fuel cells in linear regions to optimize efficiency and manage various charging scenarios. The CS integrates unity power factor grid interaction, and power support for auxiliary loads, maintaining harmonic distortion within 5% during grid islanding. The approach evaluates DC bus voltage regulation under various scenarios of PV array power fluctuations and dynamic load variations, in both grid-connected and standalone operations. In conclusion, the proposed control strategy is validated on a laboratory prototype through various dynamic load variation and grid islanding scenarios.

Khalid, Mohd [Oak Ridge National Laboratory (ORNL)↗

Chapter 10: Process Heating for Industry

The overall objective of this chapter is to help the reader better understand the technical feasibility, barriers and opportunities for renewable thermal energy systems (RTES). Solar thermal (ST) derived heat, which can be concentrating or non-concentrating, can be considered a sub-set of RTES solutions that can provide heat for industry. This chapter will focus on Industrial Process Heat (IPH) and District Heating Systems and will also highlight the difference between stand-alone and hybrid solutions. Different thermal energy sources (traditional and new) and technologies, that can provide the end-user heat delivered through many mediums, systems and for different purposes. Among various RTES, ST technologies will be the focus of this chapter.

district heating↗

Case Study: Hybrid Carbon Conversion Using Low-Carbon Energy Sources in Coal-Producing States

The demand for more carbon efficient power sources and a decrease in natural gas prices has decreased the desire for coal power. This decrease in demand has led to massive job losses in coal mining regions over the past decade. The purpose of this project is to develop a hybrid energy system utilizing both a coal power plant and advanced reactor, which is competitive with natural gas by improving on profitability and decreasing carbon emissions. This report details the problem with a summary of the impact on the coal industry and the availability of renewable energy sources in the Appalachian region. Because of the geography of the region, variable renewable energy sources are not available without significant size and siting restrictions. However, biomass in the form of wood waste is abundant and can be used as a carbon neutral energy source. Combining biomass and coal processing, in addition to thermal power plants, can increase system profits and efficiency by providing peaking power and conversion opportunities for secondary markets. The electric load is based on publicly available demand data from Appalachian Power, which services the western Virginia and southern West Virginia in the Appalachian region. The demand information is combined by service, normalized, and scaled to an average demand of 1000 kW, which will be the basis for sizing the hybrid energy system. A traditional screening curve analysis for a coal plant and advanced reactor shows that the least cost design varies significantly based on the assumed discount rate and capital recovery period. An optimization program to size the design in TEAL based on the load curve gives 10 optimal designs, all with a negative resulting net present value (NPV) and a coal plant capacity of less than 15%. Including profits from selling captured carbon at a flat rate results in a positive NPV; however, the coal capacity factor only increases to about 40%. There are limitations with this optimization as well since the price of CO2 is likely to decrease as more is sold to the conversion market. The suggested design will combine coal power, an advanced reactor, and coal and biomass coprocessing to produce a variety of products that can be sold to the conversion market while increasing system efficiency. The analysis of conversion pathways for coal and biomass reveals that multiple options will need to be included in the analysis to produce the optimal system design. Three systems will be optimized and compared to determine the best design based on the figures of merit of total NPV and cost of carbon avoided. The first system will include a coal power plant and an advanced reactor that will sell electricity to the grid to meet demand and sell captured carbon to the conversion market. The second system adds a high-temperature steam electrolysis plant, which will utilize electricity during times of low demand to produce hydrogen and sell it to the conversion market. The third system adds biomass and coal processing with options for hydrocarbon oils, syngas to be produced for the conversion market, and electricity generation to power components within the system or provide peaking power. This analysis will be based on a new approach that combines traditional screening curve methods with a dispatch algorithm that optimizes the system based on the opportunity cost of different production options. The resulting optimization algorithm should provide results with less processing time than HERON’s decision tree method. The results from this analysis will determine an optimal design and reinforce the benefits of coal power when used in a hybrid energy system. The initial results show that the addition of a secondary market for carbon sales could result in a positive NPV and increases the capacity factor of the coal plant as compared to a design with only sales to the electricity market. The addition of more markets and additional coal consumption from biomass coprocessing could increase NPV further, replace carbon in other markets through the sale of biomass-derived hydrocarbons, and demonstrate the value of coal power technology.

01 COAL, LIGNITE, AND PEAT↗

Integrated Heat Pump Thermal Storage and Power Cycle for CSP (Final Technical Report)

Pumped thermal energy storage (PTES) is a storage system that stores electricity in thermal reservoirs. In this project, methods of integrating PTES with concentrating solar power (CSP) systems were investigated and their feasibility evaluated. Hybrid "solar-PTES" devices can provide both flexible renewable power generation as well as a variety of electricity storage services. Techno-economic models of PTES and solar-PTES were developed and used to assess their performance, cost, and commercial viability. Systems were optimized using multi-objective optimization techniques. The value that these storage devices provide to the grid was estimated using production cost modelling. Key advances made in this project include the development of detailed techno-economic models that improve state-of-the-art assessments of these technologies. Off-design models were developed and used in grid-analysis models. This work describes for the first time how PTES and solar-PTES behave over a range of operating points and assesses the value that these systems can provide to the electrical grid. Feedback was obtained from experts in the field, which clarified key technological and economic barriers that must be addressed to improve the feasibility of these devices.

14 SOLAR ENERGY↗

Hydrogen-Battery Hybrid Energy System on Repurposed Offshore Platforms for Efficient Clean-Energy Transition

Due to the rising global energy demand and enhanced awareness of the environmental impact of fossil fuels, the Gulf of Mexico, traditionally known for oil extraction, offers a distinct chance to repurpose the existing offshore infrastructure. With the depletion of oil reserves, it is feasible to adapt previously utilized floating platforms for extraction to generate renewable energy, specifically through wind-generated power and hydrogen production. This adaptation seeks to promote a transport system that is more ecologically friendly in the future. Offshore wind turbines serve as the main energy source, with help from battery storage and hydrogen production to enhance the overall system performance, hydrogen creation, fuel, and electricity delivery for sustainable energy production. The system is divided into two distinct cases, each evaluated for cost, performance, and feasibility, with a focus on minimizing both the Levelized Cost of Energy (LCOE) and the Levelized Cost of Hydrogen (LCOH). The first case examines the integration of offshore wind turbines with hydrogen production. Excess electricity generated by wind turbines is directed toward hydrogen production via electrolysis. The hydrogen produced can be used as fuel for vehicles or transported to the shore via pipelines. The second case investigates a technology that combines wind turbines with battery storage. The batteries possess an ability to supply electricity for a continuous duration of 4 hours maximum each day. The main objective is to reduce the LCOE by considering the battery's charging and discharging cycles, together with the uncertain attributes of wind power and battery deterioration. The produced energy can be distributed for onshore applications or utilized for the purpose of offsetting offshore loads such as subsea oil and gas production, transportation, etc. The offshore hydrogen-battery hybrid system is improved via three advanced algorithms, Particle Swarm Optimization (PSO), and Grey Wolf Optimizer (GWO). In Case 1, PSO improves hydrogen production by efficiently managing the electrolyzer’s power consumption, decreasing production costs significantly. Particle Swarm Optimization (PSO) is applied to improve the efficiency of the electrolyzer, reducing production costs and achieving an optimized CAPEX of $240.00 million (from an initial $300.00 million) and OPEX of $9.60 million per year. This system produces 4,720,000 kg of hydrogen annually, with a Levelized Cost of Hydrogen (LCOH) of $6.40/kg and an annual profit of $9.27 million. In Case 2, GWO effectively reduces the overall energy cost by improving the charge-discharge management of batteries, which extends battery life and optimizes their use. The second case focuses on integrating battery storage, optimized using the Grey Wolf Optimizer (GWO), which enhances battery charge-discharge cycles, extending battery life and lowering costs. This system achieves an optimized CAPEX of $204.80 million (from an initial $256.00 million) and OPEX of $9.29 million per year, producing 310883.39 MWh of electricity annually at a Levelized Cost of Energy (LCOE) of $86.13/MWh, with an annual profit of $6.25 million. The implementation of a comprehensive strategy results in a substantial reduction in costs, improved energy efficiency, and a dependable supply of both electric power and hydrogen, emphasizing the benefits of converting offshore oil platforms for clean energy transition. This study explores a clean strategy to enable cost-effective repurposing of offshore O&G platforms. Both cases highlight the economic and technical feasibility of transitioning offshore oil platforms to clean energy systems, demonstrating substantial cost reductions and reliable energy and hydrogen supplies for sustainable energy production.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Design of Multi-Engine Freight Locomotive

This final report documents the completed engineering design of a modular, multi-engine renewable natural gas (RNG) hybrid freight locomotive. The project delivered a full systems design, component selection, and production and test plans for a near-zero-emission, Tier 5–capable line-haul locomotive, but did not proceed to fabrication or field testing due to withdrawal of the designated engine supplier.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Powering the Blue Economy: A Survey of Station-Keeping Methods for Mooringless Platforms

The term “ocean platform” is used to reference everything from stationary, typically moored, buoys to mobile water vehicles, whether they operate on the ocean’s surface or underwater. For certain applications for which relatively stationary station-keeping conditions are desired, the use of mooring systems is not always a viable alternative either for economic, environmental, regulatory, or otherwise practical reasons, or a combination thereof, (e.g., short deployments, sensitive ecosystems, very deep project sites). Maintaining a platform at a single waypoint or reference location without being moored would require additional control systems and a power source to counteract the drift forces that would naturally displace it. Mobile platforms, which are usually untethered except for remotely operated vehicles, typically require energy input to power their station-keeping capabilities so that they hold or control their location in the ocean. Currently, most of these platforms use combustion engines or batteries for this purpose, which, depending on the specific systems, may be costly, pollute the environment, or create limitations on the length of the deployment. However, powering this kind of platforms with surrounding renewable resources (waves, currents, winds, or sun) has been identified as a promising solution to expand their application. The intent of this report is to investigate station-keeping methods for various ocean platforms that are not moored or otherwise anchored to the ocean floor, or another platform or vessel, paying particular interest to technologies that use marine renewable resources to power their operation, because that is of particular interest to the U.S. Department of Energy’s Powering the Blue Economy (PBE) initiative. As a first step, 72 articles and technical reports related to mooringless station-keeping methods were collected for review. The preliminary literature review provided a broad overview of common themes across the literature from which a descriptive methodology for analyzing various platforms was developed. That is, station-keeping methods were categorized based on their predominant energy source and consumption (renewable, nonrenewable, or hybrid if the platform uses renewable and nonrenewable resources equally), and their localization strategy (drift reduction, “path-planning or “waypoint-holding”). In addition, platform types were segregated into the following groups: buoys, surface drifters, and unoccupied surface vehicles (USVs); offshore renewable energy systems; and unoccupied underwater vehicles (UUVs). The main types of station-keeping methods encountered in this report achieve their intended localization strategy by means of drift mitigation, steering, and/or propulsion. Drift mitigation is commonly accomplished via drogues and sea anchors. Stand-along steering subsystems use control surfaces (e.g., ship rudder, wing sail, etc.) that react to ocean currents, waves, or winds to provide varying-degrees of course adjustments. Combined steering and propulsion subsystems include differential thrusters, directional thrusters separate from a primary thruster that cause the platform to pitch up/down or yaw clockwise/counterclockwise, or vectored thrusters that direct the propulsion in a range of directions relative to the platform’s local coordinate system. Propulsion is often achieved by running a motor and applying active control strategies but can also involve buoyancy shifts and using sails to generate lifting forces that propel a platform in a desired direction. Future research is primarily expected to take place in the form of a technoeconomic analysis that would aim to determine the technological viability, cost, and added value of mooringless station-keeping use cases identified through this research, including docking for UUV recharging or for georeferencing drifter buoys, deep-sea floating wind farms, U.S. Navy sonar arrays, and a Pacific Ocean wave buoy network.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Real-Time Simulation of Solid Oxide Electrolyzers (SOEC) for Dynamic Operability Improvement and Cyber-Physical System Development

As more intermittent-renewable generations are being added to the power grid, solid oxide electrolysis cells (SOEC) must enhance their rapid load transition capabilities to load follow and support grid resilience. At NETL, we developed real-time SOEC models to research SOEC transients during load step changes. The gained insights can be useful for dynamic operability improvement. These real-time SOEC models also established the basis for cyber-physical SOEC hybrid energy systems. (Virtual presentation to the 2025 MILLENNIUM CLEAN and SUSTAINABLE POWER workshop, University of Genoa, Italy)

20 FOSSIL-FUELED POWER PLANTS↗