Search NASA⌕ Search

SEARCH · Search NASA

Results for “Isotope”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 163 records · Page 9

Leaf Wax Hydrogen Isotopes Reflect Storm Track Position Over Western North America

Proxy records of past climates have yielded powerful insights into regional hydroclimate dynamics. Novel insights may be gained by reconstructing spatiotemporal changes in precipitation isotopologues in past climate states that cannot be gleaned from individual site‐level studies. In this paper, we ask whether latitudinal gradients in the stable hydrogen isotopic composition of precipitation, as inferred from sedimentary leaf wax biomarkers, reflect aspects of large‐scale climate conditions in western North America (WNA). Modern coretop samples from offshore WNA show that leaf wax hydrogen isotopes broadly track the hydrogen isotopic composition of rainfall between 20 and 40N, but with an offset corresponding to a relatively constant “apparent fractionation” value. Poleward of 40N, the leaf wax signal may be complicated by fluvial transport of leaf waxes from the continental interior. Leaf wax‐inferred precipitation hydrogen isotopes show a shift to more negative values between 30 and 40N. We use modern observational data to show that this latitudinal range marks a major transition between the subtropical arid zone and the location of the midlatitude storm tracks over the northeast Pacific. Nudged water isotope‐enabled models capture the location of the arid to mesic climate transition with fidelity. This modern data set suggests that reconstructions of the latitudinal gradient of precipitation hydrogen isotopes can constrain the sensitivity of the storm tracks to shifts in climatic boundary conditions in past climate states. This approach can yield novel insights into past, present, and future hydroclimate variability in this arid region.

54 ENVIRONMENTAL SCIENCES↗

Carbon isotope fractionation by an ancestral rubisco suggests that biological proxies for CO 2 through geologic time should be reevaluated

The history of Earth’s carbon cycle reflects trends in atmospheric composition convolved with the evolution of photosynthesis. Fortunately, key parts of the carbon cycle have been recorded in the carbon isotope ratios of sedimentary rocks. The dominant model used to interpret this record as a proxy for ancient atmospheric CO 2 is based on carbon isotope fractionations of modern photoautotrophs, and longstanding questions remain about how their evolution might have impacted the record. Therefore, we measured both biomass (ε p ) and enzymatic (ε Rubisco ) carbon isotope fractionations of a cyanobacterial strain ( Synechococcus elongatus PCC 7942) solely expressing a putative ancestral Form 1B rubisco dating to ≫1 Ga. This strain, nicknamed ANC, grows in ambient pCO 2 and displays larger ε p values than WT, despite having a much smaller ε Rubisco (17.23 ± 0.61‰ vs. 25.18 ± 0.31‰, respectively). Surprisingly, ANC ε p exceeded ANC ε Rubisco in all conditions tested, contradicting prevailing models of cyanobacterial carbon isotope fractionation. Such models can be rectified by introducing additional isotopic fractionation associated with powered inorganic carbon uptake mechanisms present in Cyanobacteria, but this amendment hinders the ability to accurately estimate historical pCO 2 from geological data. Understanding the evolution of rubisco and the CO 2 concentrating mechanism is therefore critical for interpreting the carbon isotope record, and fluctuations in the record may reflect the evolving efficiency of carbon fixing metabolisms in addition to changes in atmospheric CO 2 .

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Stable isotopes contain substantial additive information about terrestrial carbon and water cycling

Abstract Stable isotope ratios of H ( δ 2 H ), O ( δ 18 O), and C ( δ 13 C) are linked to key biogeochemical processes of the water and carbon cycles; however, the degree to which isotope-associated processes are reflected in macroscale ecosystem flux observations remains unquantified. Here through formal information assessment, new measurements of δ 13 C of net ecosystem exchange ( NEE ) as well as δ 2 H and δ 18 O of latent heat ( LH ) fluxes across the United States National Ecological Observation Network (NEON) are used to determine conditions under which isotope measurements are informative of environmental exchanges. We find all three isotopic datasets individually contain comparable amounts of information about NEE and LH fluxes as wind speed observations. Such information from isotope measurements, however, is largely unique. Generally, δ 13 C provides more information about LH as aridity increases or mean annual precipitation decreases. δ 2 H provides more information about LH as temperatures or mean annual precipitation decreases, and also provides more information about NEE as temperatures decrease. Overall, we show that the stable isotope datasets collected by NEON contribute non-trivial amounts of new information about bulk environmental fluxes useful for interpreting biogeochemical and ecohydrological processes at landscape scales. However, the utility of this new information varies with environmental conditions at continental scales. This study provides an approach for quantifying the value adding non-traditional sensing approaches to environmental monitoring sites and the patterns identified here are expected to aid in modeling and data interpretation efforts focused on constraining carbon and water cycles’ mechanisms.

54 ENVIRONMENTAL SCIENCES↗

Discovery of new isotopes in the fragmentation of 82 Se and insights into their production

The production cross sections of neutron-rich nuclei for elements just above 60 Ca were measured at the Facility for Rare Isotope Beams (FRIB). Four previously unobserved isotopes ( 63 Sc, 65,66 Ti, and 68 V) were produced, separated, and identified for the first time using the Advanced Rare Isotope Separator (ARIS). One event was found to be consistent with 61 Ca . The new isotopes were created through the interaction of an 82 Se beam with a carbon target at an energy of 228 MeV/𝑢 and a primary beam current of 1.07 p⁢µ⁢A. The event-by-event particle identification of the mass number (𝐴), atomic number (𝑍), and ionic charge state (𝑞) for the reaction products was achieved by combining measurements of energy loss, time of flight, magnetic rigidity, and total kinetic energy. This successful search for new isotopes, conducted at the beginning of FRIB's third year of operation, highlights the facility's discovery potential, which will continue to grow as the beam current increases. The production cross sections were analyzed in the context of the newly developed Δ⁢𝐵⁢𝐸 systematics that provides trends in neutron-rich regions and increased sensitivity to nuclear binding, an important nuclear structure observable. Furthermore, the new systematics addresses gaps in 𝑄 𝑔 -based methods commonly used to interpret the production cross sections of light neutron-rich elements, and provides an efficient empirical approach to describe cross-section trends across isotopic chains. Good agreement with the measured data was obtained when the Δ⁢𝐵⁢𝐸 systematics and abrasion-ablation calculations were performed using the Hartree-Fock-Bogoliubov (HFB-22) mass table.

59 ≤ A ≤ 89↗

Giant Isotope Effect of Thermal Conductivity in Silicon Nanowires

Isotopically purified semiconductors potentially dissipate heat better than their natural, isotopically mixed counterparts as they have higher thermal conductivity (κ). But the benefit is low for Si at room temperature, amounting to only ~10% higher κ for bulk 28 Si than for bulk natural Si ( nat Si). Here we show that in stark contrast to this bulk behavior, 28 Si (99.92% enriched) nanowires have up to 150% higher κ than nat Si nanowires with similar diameters and surface morphology. Using a first-principles phonon dispersion model, this giant isotope effect is attributed to a mutual enhancement of isotope scattering and surface scattering of phonons in nat Si nanowires, correlated via transmission of phonons to the native amorphous SiO 2 shell. The Letter discovers the strongest isotope effect of κ at room temperature among all materials reported to date and inspires potential applications of isotopically enriched semiconductors in microelectronics.

36 MATERIALS SCIENCE↗

ICP-MS For Analysis of Lithium Isotopic Ratios in Materials Highly Enriched in 7 Li (CRADA 626) Final Report

The intent of this project was to determine appropriate methodologies for analysis of lithium isotopes for 1) quasi-online monitoring of isotope separations, and 2) high-precision characterization of end-products, including lithium fluoride and lithium-beryllium fluoride (FLiBe). Traditionally, isotopic analysis requires the use of expensive, sophisticated instrumentation with often relatively long analytical timelines. We determined that the use of cheaper, smaller, and easier-to-operate instruments are sufficient for rapid analysis of lithium isotopes to monitor isotope separation efficiencies. In addition, we found that the analytical precision afforded by these lower-cost instruments is comparable to the more sophisticated (i.e., more expensive) instrumentation when the isotopic composition of lithium becomes highly depleted in 6Li. This finding will ultimately help lower costs of manufacturing of depleted lithium that is required for operation of certain designs of Generation IV nuclear reactors.

07 ISOTOPE AND RADIATION SOURCES↗

Investigating preservation of stable isotope ratios in subfossil deep-sea proteinaceous coral skeletons as paleo-recorders of biogeochemical information over multimillennial timescales

Paleoproxy records in deep-sea proteinaceous coral skeletons can reconstruct past ocean conditions on centennial to millennial time scales. Commonly recovered subfossil specimens could potentially extend these archives through the Holocene. However, protein matrix stability and integrity of stable isotope proxies over multi-millennial timescales in such specimens have never been examined. Here we compare amino acid (AA) composition together with bulk and AA compound-specific carbon (δ 13 C) and nitrogen (δ 15 N) isotopes in live-collected and subfossil (~9.6–11.6 kyrs BP) Kulamanamana haumeaae deep-sea coral specimens from the central Pacific to understand the effects of long-duration benthic oxic exposure on primary coral chemistry. We find large coupled shifts in bulk δ 15 N (~7‰) and δ 13 C (~2‰) in the outermost portion (0–10 mm) of the subfossil coral, coincident with extensive alteration of the protein matrix. Microstructural changes in skeletal texture coincide with higher C/N ratios (+0.8) and isotope-based amino acid degradation parameters (e.g. ΣV ≥ 3), indicating extensive degradation of seawater-exposed gorgonin. However, interior gorgonin (>10 mm) retained amino acid molecular compositions (with exception of major Glycine loss) and bulk and amino acid-specific isotopic values that were similar to live-collected specimens. These results indicate that compound-specific isotope analysis of amino acids can reconstruct paleo-oceanographic biogeochemical and ecosystem information in subfossil corals beyond a clear diagenetic horizon, which is easily identifiable from an evaluation of C/N ratios together with the ΣV degradation proxy.

58 GEOSCIENCES↗

Tracking natural CO 2 migration through a sandstone aquifer using Sr, U and C isotopes: Chimayó, New Mexico, USA

The geochemical and isotopic characteristics of groundwaters in Chimayó, New Mexico, reflect processes that affect water quality in the Tesuque Aquifer, which overlies a leaking natural CO 2 source in a structurally complex region. In this study, select isotopes (δ 13 C, 87 Sr/ 86 Sr, 234 U/ 238 U) are applied to groundwaters to better understand CO 2 transport mechanisms and related water-rock interactions that impact Chimayó groundwater. Carbon stable isotope ratios of dissolved inorganic carbon (DIC; δ 13 CDIC = -15.10‰ to 4.50‰) identify a distinct source of upward-migrating CO 2 that interacts with the groundwater. Additionally, groundwater 87 Sr/ 86 Sr compositions (0.7098 to 0.7154) reflect intrusion of varying amounts of saline water associated with the high CO 2 source, while 234 U/ 238 U ratios corroborate presence of deep groundwater and suggest impacts from distinctive natural uranium sources are affecting groundwater. Previous work proposed two CO 2 transport mechanisms at the site: (1) dissolved in deep brine that underlies the aquifer and (2) in the gas phase; this study uses isotope mixing models to identify wells that are affected by these CO 2 transport mechanisms and demonstrates that both transport mechanisms are associated with impaired groundwaters. Overall, this study demonstrates that applying multiple isotope systems (δ 13 CDIC, 87 Sr/ 86 Sr, 234 U/ 238 U) is a dynamic tool for identifying and measuring the impact of CO 2 leakage from a sequestration site.

58 GEOSCIENCES↗

Organic contamination detection for isotopic analysis of water by laser spectroscopy

Hydrogen and oxygen stable isotope ratios (δ 2 H, δ 17 O, and δ 18 O values) are commonly used tracers of water. These ratios can be measured by isotope ratio infrared spectroscopy (IRIS). However, IRIS approaches are prone to errors induced by organic compounds present in plant, soil, and natural water samples. A novel approach using 17 O-excess values has shown promise for flagging spectrally contaminated plant samples during IRIS analysis. A systematic assessment of this flagging system is needed to prove it useful. Errors induced by methanol and ethanol water mixtures on measured IRIS and isotope ratio mass spectrometry (IRMS) results were evaluated. For IRIS analyses both liquid- and vapour-mode (via direct vapour equilibration) methods are used. The δ 2 H, δ 17 O, and δ 18 O values were measured and compared with known reference values to determine the errors induced by methanol and ethanol contamination. In addition, the 17 O-excess contamination detection approach was tested. This is a post-processing detection tool for both liquid and vapour IRIS triple-isotope analyses, utilizing calculated 17 O-excess values to flag contaminated samples. Organic contamination induced significant errors in IRIS results, not seen in IRMS results. Methanol caused larger errors than ethanol. Results from vapour-IRIS analyses had larger errors than those from liquid-IRIS analyses. The 17 O-excess approach identified methanol driven error in liquid- and vapour-mode IRIS samples at levels where isotope results became unacceptably erroneous. For ethanol contaminated samples, a mix of erroneous and correct flagging occurred with the 17 O-excess method. Here our results indicate that methanol is the more problematic contaminant for data corruption. The 17 O-excess method was therefore useful for data quality control. Organic contamination caused significant errors in IRIS stable isotope results. These errors were larger during vapour analyses than during liquid IRIS analyses, and larger for methanol than ethanol contamination. The 17 O-excess method is highly sensitive for detecting narrowband (methanol) contamination error in vapour and liquid analysis modes in IRIS.

60 APPLIED LIFE SCIENCES↗

Preparation of 241 Am/ 243 Am gravimetric mixtures and development of Am isotopic and assay measurement techniques using thermal ionization mass spectrometry

Three gravimetric mixtures with 241 Am/ 243 Am isotope ratios at nominally 1:1, 20:1, and 200:1 were prepared for calibration of the thermal ionization mass spectrometer instruments used for americium isotopic and assay measurements by isotope dilution mass spectrometry. The total evaporation analytical technique was developed for high-accuracy and precision measurements of Am isotopic ratios. The technique was also applied to Am assay measurements using isotope dilution mass spectrometry. The Am isotope ratio and assay measurement techniques were utilized to characterize batches of americium oxide separated from plutonium materials in storage at Los Alamos National Laboratory in support of commercial use of 241 AmO 2 .

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Projected network performance for multiple isotopes using next-generation xenon monitoring systems

Since about 2000 (Bowyer et al., 1998), radioxenon monitoring systems have been under development and testing for the verification of the Comprehensive Nuclear Test-Ban Treaty (CTBT). Operation of the systems since then has resulted in development of a next-generation of systems that are nearly ready for operational deployment. By 2010, the need to screen out civilian sources was well known (Auer et al., 2010; Saey, 2009), and isotopic ratio approaches were soon considered (Kalinowski et al., 2014) to identify specific sources. New generation systems are expected to improve the ability to verify the absence of nuclear tests by using isotopic ratios when multiple isotopes are detected. In this work, thousands of releases were simulated to compute the global detection probability of 131m Xe, 133m Xe, 133 Xe, and 135 Xe at 39 noble gas systems in the International Monitoring System (IMS) for both current and next-generation systems. Three release scenarios are defined at 1 h, 1 d, and 10 d past a 1 kt TNT equivalent 235U explosion event. Multiple cases using from one part in a million to the complete release of the xenon isotopic activity are evaluated for each scenario. Coverage maps and global integrals comparing current and next-generation monitoring systems are presented showing that next-generation noble gas systems will create measurable improvements in the IMS. The global detection probability for 133 Xe is shown to be strong in all scenarios, but only modestly improved by next-generation equipment. However, the detection probability for 131m Xe and 133m Xe increased to about 50% in different scenarios, providing a second detectable isotope for many events. As anticipated from shorter sampling intervals, the expected number of detecting samples roughly doubled and the expected number of detecting stations rose by approximately 50% for all release scenarios. Thus, it might be anticipated that future events would consist of multiple 133 Xe detections and one or more second isotope detections. In conclusion, signals of this nature should increase detection confidence, tighten release location estimates, improve rejection of civilian signals, and lessen the impacts from individual systems being offline for maintenance or repair reasons.

98 NUCLEAR DISARMAMENT, SAFEGUARDS, AND PHYSICAL P↗

Investigation of potential polyatomic interferences on uranium isotope ratio measurements for the LS-APGD-Orbitrap MS system

The determination of actinide (e.g., U and Pu) content and isotopics is of importance to the nuclear forensics and safeguards communities. However, in the analysis of environmental samples, such as those collected by the International Atomic Energy Agency, uranium measurements can be complicated by isobaric interferences from polyatomic variants of heavy elements (e.g., Pb). This leads to complex, time-consuming sample manipulations (i.e., separations) before determining isotope ratios. An alternative strategy to sample pretreatment is to use high-resolution mass spectrometric platforms during the analysis to fully resolve the uranium isotopes from potential polyatomic interferences, negating the need for prior chemical separation. The liquid sampling - atmospheric pressure glow discharge (LS-APGD) coupled with an Orbitrap mass spectrometer provides a high-resolution (>70,000 m/Δm at m/z 200) inorganic mass spectrometry platform. Further, as a demonstration of the power of this instrumental platform, and indeed, the high-resolution approach in general, uranium isotope ratios were determined in the presence of elemental impurities (e.g., Pb, Pt, Ta, W) commonly encountered with environmental sample swipe analysis, without any prior treatment. Even at elemental impurity concentrations of 1000–5000× relative to uranium, no interference was observed with the 235 U or 238 U signal. In addition, the 235 U/ 238 U isotope ratio for the samples with the concomitants present are within 2 standard deviations of the values obtained without their addition, indicating that these impurities do not impact the determined uranium isotope ratio. These findings represent a significant first step in leveraging the high resolution of the LS-APGD-Orbitrap-MS to overcome isobaric and molecular interferences instead of relying on chemical separations.

38 RADIATION CHEMISTRY, RADIOCHEMISTRY, AND NUCLEA↗

Distinguishing fissile uranium isotopes using an active well neutron coincidence counter

Proposed thorium-based nuclear fuel cycles are likely to require quantification and verification of 233 U within nuclear material. Because of their similar fission cross sections, active neutron nondestructive assay (NDA) systems may respond similarly to 233 U and 235 U. Traditional safeguards equipment has been optimized for 235 U and 238 U quantification associated with conventional uranium/plutonium fuel cycles and may not be directly applicable to 233 U quantification when mixed with other actinides. This work used models of the large volume active well coincidence counter (LV-AWCC) at Oak Ridge National Laboratory to evaluate the performance of this neutron NDA system to differentiate fissile uranium isotopes. The models were developed to simulate NDA system performance in response to a number of triangular radiation signature training device sources within the central cavity or well. This work predicted that the LV-AWCC can effectively differentiate 233 U from 235 U in certain modes of operation. In active mode, the LV-AWCC with the cadmium liner results in different doubles count rates between the fissile isotopes for a given fissile uranium mass. Without the cadmium liner, the uranium isotopes provide a statistically indistinguishable doubles count rate response for the fissile masses considered in this work (up to approximately 150 g). The cadmium liner serves to harden the neutron interrogation spectrum, which better exploits the notable difference in the 233 U and 235 U fission cross sections at approximately 1 eV. In passive mode, the two fissile isotopes exhibit different doubles and singles count rates regardless of liner presence because the passive source strength of 233 U is approximately 2 orders of magnitude stronger than that of 235 U due to the shorter half-life and correspondingly higher (α, n) yield. We conclude that using neutron interrogation in the LV-AWCC, two measurements are needed to quantify 233 U content in mixed uranium items. The first measurement is used to determine the total fissile uranium mass using a mode that cannot distinguish fissile isotopes (i.e., where a similar response is observed for both fissile uranium isotopes such as active doubles without cadmium or using a thermal neutron interrogation source). In conclusion, the second measurement is used to determine the 233 U content by using a differentiating technique (e.g., passive doubles, passive doubles to singles ratio, active doubles with cadmium).

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Coupled neutronics, thermochemistry, corrosion modeling and sensitivity analyses for isotopic evolution in molten salt reactors

This study presents a computational methodology for analyzing isotopic evolution and associated uncertainties in molten salt reactors (MSRs), focusing on both fluoride- and chloride-based fuel salts. The primary goal is to enhance the understanding of isotopic behavior in MSRs and provide data to support future experimental efforts. The methodology integrates transport-coupled depletion calculations using OpenMC, equilibrium thermodynamics modeling with Thermochimica, and a corrosion model. Sensitivity analyses are performed to evaluate the impact of power density, air ingress, and humidity content on isotopic evolution in MSR concepts. This study examines representative F- and Cl-based MSR designs, highlighting the dominant influence of power density on isotopic composition, which significantly affects isotope production and depletion rates, accounting for approximately 76% of the observed variance in element concentration. Air ingress and humidity content also affect the redox potential, solubility of heavier elements, and corrosion rates, thereby altering the expected isotopic evolution in the reactor. On average, air ingress accounts for around 17% of the variance in element concentrations, while humidity explains the remaining 7%. These variances differ significantly from element to element, depending on the element’s role in depletion, redox potential evolution, and galvanic corrosion. The findings indicate that power density, air ingress, and humidity content are all critical factors for optimizing reactor design and operational strategies. Furthermore, the study provides expected ranges for key impurities in the fuel salt, which are crucial for guiding future experimental studies and refining MSR designs. Finally, this study demonstrates the importance of modeling depletion coupled with the evolution of redox potential and chemical interactions in MSR fuel salts.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

Controlled Release of Hydrogen Isotopes from Hydride-Magnetic Nanomaterials

In this work, hydrogen isotopes in the form of protium and deuterium were rapidly desorbed from magnetic-hydride iron oxide-palladium (Fe 2 O 3 -Pd) hybrid nanomaterials using an alternating magnetic field (AMF). Palladium, a hydride material with a well-known hydrogen isotope effect, was deposited on Fe 2 O 3 magnetic nanoparticle support by solution chemistries and used as a hydrogen isotope storage component. The morphological, structural, optical, and magnetic studies reveal that the Fe 2 O 3 -Pd nanoparticles (NPs) are hybrid structures exhibiting both hydrogen isotope storage (Pd) and magnetic (Fe 2 O 3 ) properties. The hydrogen isotope sorption/desorption behavior of metal hydride-magnetic nanomaterials was assessed by isothermal pressure-composition response curves (isotherms). The amount and rate of hydrogen isotope gas release was tuned by simply adjusting the strength of the magnetic field strength applied. Protium and deuterium displayed a similar loading capacity, namely H/M 0.55 and H/M=0.45, but different plateau pressures. Significant differences in the kinetics of release for protium and deuterium during magnetic heating were observed. A series of magnetically induced charge-discharge cycling experiments were conducted showing that this is a highly reproducible and robust process

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Modeling Snow Dynamics and Stable Water Isotopes Across Mountain Landscapes

Abstract A coupled hydrologic and snowpack stable water isotope model assesses controls on isotopic inputs across a mountainous basin. Annually, the most depleted isotope conditions occur in the upper subalpine where snow accumulation is high, and rainfall is low. Snowmelt isotopic evolution over time indicates fractionation processes account for <25% snowmelt enrichment. Meltwater isotopic inputs are largely determined by controls on the amount, phase and isotopic mass of precipitation coincident with the ablation period. Effect of vapor loss from the snowpack on d‐excess in snowmelt is a balance between energy and snow‐availability. It is highest above treeline, and in the grass and aspen‐dominated portions of the upper montane where vegetation shading is low. Deep snowpack in conifer forests limit the influence of vapor loss in the subalpine. Wet years reduce the effects of vapor loss on snowmelt across the basin, except in the lower montane where added snowfall bolsters snow‐limited conditions.

58 GEOSCIENCES↗

Factors controlling the oxygen isotopic composition of lacustrine authigenic carbonates in Western China: implications for paleoclimate reconstructions

Abstract In the carbonate-water system, at equilibrium, the oxygen isotopic composition of carbonate is dependent not only on the temperature but also on the isotopic composition of host water in which the carbonate is formed. In this study, lake surface sediment and water samples were collected from 33 terminal lakes in Western China to evaluate controls on the oxygen isotopic composition of lacustrine authigenic carbonates (δ 18 O carb ) and its spatial distribution. Our results show that water oxygen isotopic composition (δ 18 O water ) rather than lake summer water temperature (T water ), is the main determinant of δ 18 O carb , irrespective of whether oxygen isotope equilibrium is achieved. There are significant linear correlations between δ 18 O carb and elevation, as well as that between δ 18 O carb and latitude for lakes located on the Tibetan Plateau. In Western China, the spatial distribution of δ 18 O carb is consistent with that of δ 18 O water , and is ultimately controlled by the isotopic composition of local precipitation (δ 18 O precipitation ) that depends on the source of water vapor. Therefore, changes in δ 18 O carb can be predominantly interpreted as variations of δ 18 O water , which in turn represent changes in δ 18 O precipitation for paleoclimate reconstructions in this region, and may be relevant to studies of other areas.

59 BASIC BIOLOGICAL SCIENCES↗

Boron isotopic analysis in bulk silicate materials using the Neoma MS/MS MC-ICP-MS

Boron (B) isotopes are a valuable tracer with applications ranging from geological, environmental, and nuclear studies because B isotopic fractionation is highly sensitive to chemical processes yielding distinct isotopic trends in natural and anthropogenic systems. Despite this wide applicability, there remain relatively few measurements on well-described reference materials and in some cases, poor agreement between various methods. We report a method for boron isotope ratio measurement in solution on the Neoma MS/MS MC-ICP-MS specifically targeting bulk silicates. We evaluate the performance of the method and instrument as it relates to the measurement of the absolute boron isotope ratio ( 10 B/ 11 B). The results indicate that the method produces data in agreement with literature values and that the sample–standard bracketing technique is appropriate for the Neoma MS/MS MC-ICP-MS which has been in use for decades on previous generation instruments. Careful tuning of the MS/MS lenses is required to obtain precision comparable to non MS/MS equipped MC-ICP-MS. With careful tuning, internal and external precisions of ∼0.3‰ were achieved. However, when the MS/MS is not properly tuned external precisions exceed 3‰. Nevertheless, our results for IAEA B-6, BCR-2, BHVO-2 and W-2a reference materials overlap the 1σ range of previously reported 10 B/ 11 B. Data are reported for total boron quantities down to a few tens of nanograms. Our procedure yielded blanks as low as 3 ng but up to 29 ng, making blank corrections important for small samples sizes in the few 10s of nanogram range. We report B isotope ratios for AGV-2G, SL-1G, GSC-2G, GSD-2G, GSE-2G, RLS-132, RLS-140, NKT-1G, and T1-G glass reference materials that have not been previously reported in the literature.

Scott, Sean R. [Pacific Northwest National Laborat↗