Search NASA⌕ Search

SEARCH · Search NASA

Results for “LOCATION”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 163 records · Page 9

Improved Method of Locating Defects in Wiring Insulation

An improved method of locating small breaches in insulation on electrical wires combines aspects of the prior dielectric withstand voltage (DWV) and time-domain reflectometry (TDR) methods. The method was invented to satisfy a need for reliably and quickly locating insulation defects in spacecraft, aircraft, ships, and other complex systems that contain large amounts of wiring, much of it enclosed in structures that make it difficult to inspect. In the DWV method, one applies a predetermined potential (usually 1.5 kV DC) to the wiring and notes whether the voltage causes any arcing between the wiring and ground. The DWV method does not provide an indication of the location of the defect (unless, in an exceptional case, the arc happens to be visible). In addition, if there is no electrically conductive component at ground potential within about 0.010 in. (approximately equal to 0.254 mm) of the wire at the location of an insulation defect, then the DWV method does not provide an indication of the defect. Moreover, one does not have the option to raise the potential in an effort to increase the detectability of such a defect because doing so can harm previously undamaged insulation. In the TDR method as practiced heretofore, one applies a pulse of electricity having an amplitude of less than 25 V to a wire and measures the round-trip travel time for the reflection of the pulse from a defect. The distance along the wire from the point of application of the pulse to the defect is then calculated as the product of half the round-trip travel time and the characteristic speed of a propagation of an electromagnetic signal in the wire. While the TDR method as practiced heretofore can be used to locate a short or open circuit, it does not ordinarily enable one to locate a small breach in insulation because the pulse voltage is too low to cause arcing and thus too low to induce an impedance discontinuity large enough to generate a measurable reflection. The present improved method overcomes the weaknesses of both the prior DWV and the prior TDR method.

Greulich, Owen R.↗

A Probabilistic, Facility-Centric Approach to Lightning Strike Location

A new probabilistic facility-centric approach to lightning strike location has been developed. This process uses the bivariate Gaussian distribution of probability density provided by the current lightning location error ellipse for the most likely location of a lightning stroke and integrates it to determine the probability that the stroke is inside any specified radius of any location, even if that location is not centered on or even with the location error ellipse. This technique is adapted from a method of calculating the probability of debris collision~ith spacecraft. Such a technique is important in spaceport processing activities because it allows engineers to quantify the risk of induced current damage to critical electronics due to nearby lightning strokes. This technique was tested extensively and is now in use by space launch organizations at Kennedy Space Center and Cape Canaveral Air Force Station. Future applications could include forensic meteorology.

Huddleston, Lisa L.↗

Method for the Absolute Calibration of the Location and Orientation of Large-Format Detectors Using Laser Radar

A method of mapping pixel locations of a detector array includes measuring a location on the detector array, initiating a frame readout of the detector array, measuring a location of one or more metrology targets on the detector array, analyzing the frame readout to identify a pixel at the location on the detector array, and defining a location of the identified pixel with respect to the location of the one or more metrology targets. Subsequent measurement of the metrology targets alone by another metrology system allows one to infer the six degree of freedom alignment of the detector array in space.

Coulter, Phillip↗

Robotic External Leak Locator (RELL) Leak Plume Field Detection on the International Space Station (ISS)

The Robotic External Leak Locator (RELL) was deployed to the International Space Station (ISS) with the objective of demonstrating the ability to detect and locate small leaks. On-orbit operations began in late November 2016 and following scanning activities to characterize the natural and induced environment of the ISS, RELL focused on the United States External Active Thermal Control System (EATCS). RELL successfully detected ammonia related to a known small ammonia leak in the port-side EATCS, with the highest pressure values around the inboard Radiator Beam Valve Module 1 (RBVM 1). An additional day of scanning was subsequently performed in December 2017 to focus on RBVM 1. RELL was approved for additional external operations in February 2017 with the goal of fine tuning the location of the leak. Using grid scanning patterns, RELL detected ammonia around RBVM 1 and located the approximate source of the leak. The potential leak site was inspected by a crew member during an Extravehicular Activity (EVA) in March 2017, and the suspected radiator-side lines were isolated from the port-side EATCS coolant loop in April 2017. Subsequent monitoring of the system pressures showed that the leak has stopped, indicating RELL accurately located the source of the EATCS leak. These activities verify that RELL enhances the ISS Program's ability to not only locate small leaks, but isolate the source with minimal impact to the entire ISS system.

External Active Thermal Control System↗

Adaptive Pressure Profile Method to Locate the Isolator Shock Train Leading Edge Given Limited Pressure Information

To maximize the performance of high-speed air-breathing engines, such as dual-mode scramjets, the streamwise location of the shock train leading edge (STLE) is ideally placed as far upstream in the isolator as possible while avoiding engine unstart. Thus, it is of interest to quantify and control the STLE location as the vehicle travels along its flight trajectory. The STLE location is typically quantified using wall static pressure measurements but there are often restrictions on the number and placement of transducers, thus reducing the accuracy and overall capability of STLE detection methods. In this work, the Adaptive Pressure Profile (APP) method is introduced to address such sparsity concerns. This method is data driven and does not heavily rely on prior information about the flow regime or engine model. Instead, the \mname method uses real-time pressure measurements from a small number of transducers to adaptively learn the isolator pressure profile. This adaptively-learned profile is fit to the pressure data at each time instance to estimate STLE location. The \mname method produces accurate estimates even when (1) the STLE location is not bounded by two or more transducers or (2) when the STLE location is between two transducers that are situated several duct heights apart. Data from two direct-connect isolator models are used to evaluate the accuracy of the \mname method and demonstrate its robustness for different back-pressure scenarios and transducer configurations.

Robin L Hunt↗

Adaptive Pressure Profile Method to Locate the Isolator Shock Train Leading Edge Given Limited Pressure Information

To maximize the performance of high-speed air-breathing engines, such as dual-mode scramjets, the streamwise location of the shock train leading edge (STLE) is ideally placed as far upstream in the isolator as possible while avoiding engine unstart. Thus, it is of interest to quantify and control the STLE location as the vehicle travels along its flight trajectory. The STLE location is typically quantified using wall static pressure measurements but there are often restrictions on the number and placement of transducers, thus reducing the accuracy and overall capability of STLE detection methods. In this work, the Adaptive Pressure Profile (APP) method is introduced to address such sparsity concerns. This method is data driven and does not heavily rely on prior information about the flow regime or engine model. Instead, the \mname method uses real-time pressure measurements from a small number of transducers to adaptively learn the isolator pressure profile. This adaptively-learned profile is fit to the pressure data at each time instance to estimate STLE location. The \mname method produces accurate estimates even when (1) the STLE location is not bounded by two or more transducers or (2) when the STLE location is between two transducers that are situated several duct heights apart. Data from two direct-connect isolator models are used to evaluate the accuracy of the \mname method and demonstrate its robustness for different back-pressure scenarios and transducer configurations.

Robin Hunt↗

Regional Modeling and Simulation for Vertiport Location Assessment

There is increasing interest in the Urban Air Mobility concept and the realization of electric Vertical Take-Off and Landing (e-VTOL) vehicles flying in the National Airspace System. NASA, FAA, and the industry are investigating various aspects of this new mode of transportation for cargo and humans. There are significant challenges in making this mode a reality, including feasibility, safety, infrastructure, traffic management, public acceptance, and scalability. From the infrastructure perspective, one of the aspects that needs to be addressed is the location of vertiports (named similar to heliports, for vertical take-off and landing vehicles). There is significant on-going research for selecting location of vertiports. However, the locations are largely based on demand models. Also, these efforts are focused in specific local regions, San Francisco/Bay Area, Chicago, Tampa, etc. This talk presents an approach to determine the location of vertiports in regional areas (across the United States), incorporating the desire to have certain attributes closer to or further from the location using a regional modeling tool. The feasibility of flying e-VTOL vehicles between various vertiport locations is also presented using a mobility operations simulation tool.

Air Mobility↗

Fuel from wastewater : harnessing a potential energy source in Canada through the co-location of algae biofuel production to sources of effluent, heat and CO2.

Sandia National Laboratories is collaborating with the National Research Council (NRC) Canada and the National Renewable Energy Laboratory (NREL) to develop a decision-support model that will evaluate the tradeoffs associated with high-latitude algae biofuel production co-located with wastewater, CO2, and waste heat. This project helps Canada meet its goal of diversifying fuel sources with algae-based biofuels. The biofuel production will provide a wide range of benefits including wastewater treatment, CO2 reuse and reduction of demand for fossil-based fuels. The higher energy density in algae-based fuels gives them an advantage over crop-based biofuels as the 'production' footprint required is much less, resulting in less water consumed and little, if any conversion of agricultural land from food to fuel production. Besides being a potential source for liquid fuel, algae have the potential to be used to generate electricity through the burning of dried biomass, or anaerobically digested to generate methane for electricity production. Co-locating algae production with waste streams may be crucial for making algae an economically valuable fuel source, and will certainly improve its overall ecological sustainability. The modeling process will address these questions, and others that are important to the use of water for energy production: What are the locations where all resources are co-located, and what volumes of algal biomass and oil can be produced there? In locations where co-location does not occur, what resources should be transported, and how far, while maintaining economic viability? This work is being funded through the U.S. Department of Energy (DOE) Biomass Program Office of Energy Efficiency and Renewable Energy, and is part of a larger collaborative effort that includes sampling, strain isolation, strain characterization and cultivation being performed by the NREL and Canada's NRC. Results from the NREL / NRC collaboration including specific productivities of selected algal strains will eventually be incorporated into this model.

03 NATURAL GAS↗

Helicopter magnetic survey conducted to locate wells

A helicopter magnetic survey was conducted in August 2007 over 15.6 sq mi at the Naval Petroleum Reserve No. 3’s (NPR-3) Teapot Dome Field near Casper, Wyoming. The survey’s purpose was to accurately locate wells drilled there during more than 90 years of continuous oilfield operation. The survey was conducted at low altitude and with closely spaced flight lines to improve the detection of wells with weak magnetic response and to increase the resolution of closely spaced wells. The survey was in preparation for a planned CO2 flood for EOR, which requires a complete well inventory with accurate locations for all existing wells. The magnetic survey was intended to locate wells missing from the well database and to provide accurate locations for all wells. The ability of the helicopter magnetic survey to accurately locate wells was accomplished by comparing airborne well picks with well locations from an intense ground search of a small test area.

02 PETROLEUM↗

Identifying the location of the OMP separatrix in DIII-D using power accounting

In order to identify reliable scalings for the scrape-off layer (SOL) power width it is necessary to know the location of the separatrix in divertor tokamaks as accurately as possible, specifically its location at the outside midplane (OMP) the standard reference location. Two methods are described which use power accounting to improve the accuracy of identifying the location of the OMP separatrix. The first uses the infrared-measured deposited power profile at the outer target as the primary input, the ' $P_{{\rm SOL}}^{{\rm exhaust}}$ method'. The second uses the measured power input to the SOL, obtained by subtracting the power radiated from inside the separatrix from the total heating power, the ' $P_{{\rm SOL}}^{{\rm input}}$ method'. Furthermore, these two power accounting methods are illustrated with the examples of 21 H-mode DIII-D discharges. High spatial resolution Thomson scattering measured profiles of ne and Te for the main SOL near the OMP are also used as primary input to the analysis; only between-edge localized mode data are used here. The Thomson profiles are used to calculate the electron parallel conducted heat flux profiles which are then matched to the measured $P_{{\rm SOL}}^{{\rm exhaust}}$ and $P_{{\rm SOL}}^{{\rm input}}$ by adjusting the location of the OMP separatrix relative to that of the Thomson data. For these attached discharges, it is found that the values of $R_{{\rm sep}}^{{\rm omp}}$ given by the two power accounting methods agree to within ~1 mm of each other and also to within ~1 mm of the values given by the 'standard DIII-D method' described by Porter et al (1998 Phys. Plasmas 5 1410). Lastly, the shifted $R_{{\rm sep}}^{{\rm omp}}$ results in only modest changes to the values of ne and Te at the OMP separatrix relative to the 'standard' values, increasing $n_{{\rm e}}^{{\rm sep}}$ by 8% and $T_{{\rm e}}^{{\rm sep}}$ by 20%.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Multisource Data Fusion Outage Location in Distribution Systems via Probabilistic Graphical Models

Efficient outage location is critical to enhancing the resilience of power distribution systems. However, accurate outage location requires combining massive evidence received from diverse data sources, including smart meter (SM) last gasp signals, customer trouble calls, social media messages, weather data, vegetation information, and physical parameters of the network. This is a computationally complex task due to the high dimensionality of data in distribution grids. In this paper, we propose a multi-source data fusion approach to locate outage events in partially observable distribution systems using Bayesian networks (BNs). A novel aspect of the proposed approach is that it takes multi-source evidence and the complex structure of distribution systems into account using a probabilistic graphical method. Our method can radically reduce the computational complexity of outage location inference in high-dimensional spaces. The graphical structure of the proposed BN is established based on the network’s topology and the causal relationship between random variables, such as the states of branches/customers and evidence. Utilizing this graphical model, accurate outage locations are obtained by leveraging a Gibbs sampling (GS) method, to infer the probabilities of de-energization for all branches. Compared with commonly-used exact inference methods that have exponential complexity in the size of the BN, GS quantifies the target conditional probability distributions in a timely manner. As a result, a case study of several real-world distribution systems is presented to validate the proposed method.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Overview of Opportunities for Co-Location of Solar Energy Technologies and Vegetation

Large-scale solar facilities have the potential to contribute significantly to national electricity production. Many solar installations are large-scale or utility-scale, with a capacity over 1 MW and connected directly to the electric grid. Large-scale solar facilities offer an opportunity to achieve economies of scale in solar deployment, yet there have been concerns about the amount of land required for solar projects and the impact of solar projects on local habitat. During the site preparation phase for utility-scale solar facilities, developers often grade land and remove all vegetation to minimize installation and operational costs, prevent plants from shading panels, and minimize potential fire or wildlife risks. However, the common site preparation practice of removing vegetation can be avoided in certain circumstances, and there have been successful examples where solar facilities have been co-located with agricultural operations or have native vegetation growing beneath the panels. In this study we outline some of the impacts that large-scale solar facilities can have on the local environment, provide examples of installations where impacts have been minimized through co-location with vegetation, characterize the types of co-location, and give an overview of the potential benefits from co-location of solar energy projects and vegetation. The varieties of co-location can be replicated or modified for site-specific use at other solar energy installations around the world. We conclude with opportunities to improve upon our understanding of ways to reduce the environmental impacts of large-scale solar installations.

14 SOLAR ENERGY↗

EVI-LOCATE User Manual

One of the longest stages in the deployment of electric vehicle supply equipment (EVSE) is the initial planning of the infrastructure itself. Engineers and fleet experts from the National Renewable Energy Laboratory (NREL) have supported dozens of charging infrastructure site plans over the past couple decades, including the generation of site schematics, determinations of electric capacity, and estimates for likely costs. As the market for electric vehicles (EVs) has matured, this approach should no longer require a time and personnel intensive process. In order to shorten the time taken to develop site plans and cost estimates, NREL developed a tool that fleet managers, facility managers, electricians, EVSE installers, and members of the public can use to develop initial schematics and ballpark pricing for charging station installations. The Electric Vehicle Infrastructure - Locally Optimized Charger Assessment Tool and Estimator (EVI-LOCATE) provides a structured and consistent way for users to enter information about their planned EVSE project in a relatively simple web-based format. EVI-LOCATE then calculates electrical equipment capacity, wiring runs, and project costs. It produces a site diagram optimized around surface characteristics with differential trenching costs for softscape such as grass compared to hardscape such as asphalt that can be adjusted by users in the tool. It also stores the resulting site plans and costs in a dashboard for access at a later date, including plan revisions if necessary. This document guides users through the EVI-LOCATE screens and associated questions. It contains tip text boxes throughout on how best to interface with the tool and find additional information or context. The appendices contain the assumptions and calculations underpinning the tool. Much of the information for EVI-LOCATE was gathered through industry engagements with EVSE installers, invoices from completed EVSE installations, Gordian's RS Means construction data, and the General Services Administration blanket purchase agreement for EVSE. For a visual tutorial of the tool, users can watch EVI-LOCATE Step-by-Step Video. The tool itself is available at https://evi-locate.nrel.gov.

29 ENERGY PLANNING, POLICY, AND ECONOMY↗

Locating Partial Discharges in Power Transformers with Convolutional Iterative Filtering

The most common source of transformer failure is in the insulation, and the most prevalent warning signal for insulation weakness is partial discharge (PD). Locating the positions of these partial discharges would help repair the transformer to prevent failures. This work investigates algorithms that could be deployed to locate the position of a PD event using data from ultra-high frequency (UHF) sensors inside the transformer. These algorithms typically proceed in two steps: first determining the signal arrival time, and then locating the position based on time differences. This paper reviews available methods for each task and then propose new algorithms: a convolutional iterative filter with thresholding (CIFT) to determine the signal arrival time and a reference table of travel times to resolve the source location. The effectiveness of these algorithms are tested with a set of laboratory-triggered PD events and two sets of simulated PD events inside transformers in production use. Tests show the new approach provides more accurate locations than the best-known data analysis algorithms, and the difference is particularly large, 3.7X, when the signal sources are far from sensors.

47 OTHER INSTRUMENTATION↗

False positives in PIRADS (V2) 3, 4, and 5 lesions: relationship with reader experience and zonal location

Purpose: To investigate the effect of reader experience and zonal location on the occurrence of false positives (FPs) in PIRADS (V2) 3, 4, and 5 lesions on multiparametric (MP)-MRI of the prostate. Materials and methods: This retrospective study included 139 patients who had consecutively undergone an MP-MRI of the prostate in combination with a transrectal ultrasound MRI fusion-guided biopsy between 2014 and 2017. MRI exams were prospectively read by a group of inexperienced radiologists (cohort 1; 54 patients) and an experienced radiologist (cohort 2; 85 patients). Multivariable logistic regression analysis was performed to determine the association of experience of the radiologist and zonal location with a FP reading. FP rates were compared between readings by inexperienced and experienced radiologists according to zonal location, using Chi-square (χ{sup 2}) tests. Results: A total of 168 lesions in 139 patients were detected. Median patient age was 68 years (Interquartile range (IQR) 62.5–73), and median PSA was 10.9 ng/mL (IQR 7.6–15.9) for the entire patient cohort. According to multivariable logistic regression, inexperience of the radiologist was significantly (P = 0.044, odds ratio 1.927, 95% confidence interval [CI] 1.017–3.651) and independently associated with a FP reading, while zonal location was not (P = 0.202, odds ratio 1.444, 95% CI 0.820–2.539). In the transition zone (TZ), the FP rate of the inexperienced radiologists 59% (17/29) was significantly higher (χ{sup 2}P = 0.033) than that of the experienced radiologist 33% (13/40). Conclusion: Inexperience of the radiologist is significantly and independently associated with a FP reading, while zonal location is not. Inexperienced radiologists have a significantly higher FP rate in the TZ.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Experimental and Numerical Analysis of Liquid Metal Embrittlement Crack Location

Advanced high-strength steels used in automotive structural components are commonly protected using zinc coatings. However, the steel/zinc system creates the potential for liquid metal embrittlement during welding. Although liquid metal embrittlement cracks are known to form, the current literature does not include crack location when assessing crack severity. In this work, TRIP1100 joints showed that LME cracks decreased strength from 7.8 to 42.2%, depending on location, between the coated (cracked) and uncoated (non-cracked) condition. Liquid metal embrittlement cracks in critical locations were observed to propagate until fracture from lap shear testing. However, cracks in non-critically loaded areas were not part of the fracture path and did not result in a significant loss in strength. This shows LME crack location can be controlled to improve joint performance and vehicle safety. In addition, a model of lap shear testing in a cracked sample showed how the presence of a crack can affect the internal stress field depending on its location.

36 MATERIALS SCIENCE↗

Simulated effect of defect volume and location on very high cycle fatigue of laser beam powder bed fused AlSi10Mg

This study quantifies the interaction between volumetric defect location and size on the very high cycle fatigue (VHCF) of laser beam powder bed fused (LB-PBF) AlSi10Mg. Crystal plasticity finite element method (CPFEM) simulations were used to investigate the effects of defect location and size on the driving force for crack initiation. The CPFEM model was calibrated against uniaxial and cyclic experimental data of LB-PBF AlSi10Mg. Defect characteristics were informed by experimental data from the specimens produced in various geometries to create realistic representative volume elements (RVEs) with equivalent volume fractions of defects. By embedding defects of varying sizes and locations within the RVEs, fatigue indicator parameters (FIPs) were calculated to analyze the impact of defects’ characteristics on fatigue performance. Different combinations of defect volume and locations were generated for various microstructure instantiations, providing insight into extreme value fatigue responses. Larger defect volumes located on free surfaces consistently generated the highest FIPs, suggesting defect size and boundary proximity intensify stress concentration effects. RVEs with multiple smaller defects produced lower FIPs than those with single large critical defects. These findings underscore the critical role of defect characteristics on fatigue life, providing a foundation for future predictive modeling in fatigue-sensitive AM applications.

AlSi10Mg↗

Tumor Location, Interval Between Surgery and Radiotherapy, and Boost Technique Influence Local Control After Breast-Conserving Surgery and Radiation: Retrospective Analysis of Monoinstitutional Long-Term Results

Purpose: To obtain long-term data on local tumor control after treatment of invasive breast cancer by breast-conserving surgery and adjuvant radiotherapy (RT), in consideration of the interstitial high-dose-rate boost technique. Patients and Methods: A total of 263 women with 268 mammary carcinomas (International Union Against Cancer Stage I-IIB) who had undergone breast-conserving surgery and adjuvant RT between 1990 and 1994 were included. The potential risk factors for local recurrence-free survival were investigated. Results: During a median follow-up period of 94 months, 27 locoregional recurrences, 25 of which were in breast, were diagnosed. The cumulative rate of in-breast recurrence was 4.1% {+-} 1.4% at 5 years of follow-up and 9.9% {+-} 2.4% at 10 years. The multivariate analysis identified medial tumor location and delayed RT (defined as an interval of >2 months between surgery and the start of RT) as significant risk factors for in-breast recurrence in the overall study population. Medial tumor location vs. lateral/central location (hazard ratio, 2.48; 95% confidence interval, 1.06-5.84) resulted in a cumulative in-breast recurrence rate of 22.5% {+-} 8.3% vs. 6.9% {+-} 2.3% at 10 years. Delayed RT (hazard ratio, 2.84; 95% confidence interval, 1.13-7.13) resulted in a cumulative in-breast recurrence rate of 18.5% {+-} 6.2% vs. 6.8% {+-} 2.4% at 10 years. The multivariate analysis also showed that the risk of in-breast recurrence was lower after high-dose-rate boost therapy than after external beam boost therapy in patients with laterally/centrally located tumors (hazard ratio, 3.25; 95% confidence interval, 0.91-11.65). Conclusion: Tumor location, interval between surgery and RT, and boost technique might influence local control of breast cancer treated by breast-conserving surgery and RT.

62 RADIOLOGY AND NUCLEAR MEDICINE↗