Search NASA⌕ Search

SEARCH · Search NASA

Results for “Lab Testing”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 163 records · Page 9

Hanford Waste Treatment Plant LAB Facility Stack Effluent Monitoring: Sampling Probe Location Qualification Evaluation

The Waste Treatment Plant laboratory (LAB) facility stack monitor locations were qualified using scale model stacks to mitigate the risk of identifying that sampling locations do not meet the qualification criteria on the full-scale stack. As required by the American National Standards Institute/Health Physics Society (ANSI/HPS) N13.1-1999 standard, the scale model and its sampling location were geometrically similar to the actual stack and the Reynolds numbers for both the actual and model stacks were >10,000. An additional criterion is that the product of the hydraulic diameter and mean velocity (DV) of the full-scale stack must be between 1/6 DV and 6 DV of the scale model stack tests. Verification tests of the LAB stacks were performed at normal operating conditions. The minimum 1/6 DV value, along with the maximum 6 DV value from the scale model testing determines the range of conditions for which the full-scale stack may be operated and remain in compliance with the stack verification criterion. Based on these DV values, the corresponding stack flow rates for each of the LAB stacks are 625 to 47,237 scfm for LB-C2, 1,704 to 103,131 scfm for LB-S1, and 467 to 18,088 scfm for LB-S2. The remaining criteria for the stack verification to be considered valid involve the flow angle and velocity uniformity results. First, the flow angle at the full-scale stack must be =20°. Second, the velocity uniformity at the full-scale stack must be =20% coefficient of variance (COV). Finally, the velocity uniformity results for the actual and scale model stack tests must agree within 5% COV. These criteria were met through the full-scale stack tests at the LAB facility. Flow angle results were primarily less than 10 degrees, except for the LB-C2 Fan A results, which were an average of 17.6 degrees; all flow angle results were within the =20° criterion. The velocity uniformity results for each test condition averaged between 1.5 and 3.5% COV, which were all within the range of the target %COV values from the scale model tests. Based on these stack verification test results, the three LAB filtered exhaust stack sampling locations meet the qualification criteria provided in the ANSI/HPS N13.1-1999 standard for all fan operating configurations. This includes single-fan as well as dual-fan operations for LB-C2, each of the dual-fan operating conditions for LB-S1, and each single-fan operating condition for LB-S2. Further changes to the system configuration or operating conditions that are outside the bounds described in this report may require additional tests or analyses to determine compliance with the standard.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Solar Receiver with Integrated Thermal Storage for a Supercritical Carbon Dioxide Power Cycle

This project endeavors to design and demonstrate an integrated CSP system that meets the Department of Energy’s 6¢/kW-hr LCOE goal [1]. This design is based on the 10 MWe Supercritical Transformational Electric Power (STEP) engine specifications, but adaptable to any sCO 2 power module up to 10 MW e . The enabling technology to be tested is a new class of metal hydride based thermal energy storage materials which can store thermal energy in the hydrogen bonds between the metal hydride and hydrogen. This thermochemical energy storage solution provides a much greater energy density than sensible and latent energy storage enabling an integrated system design that closely linked the metal hydride to the power block. This allows the entire system to be mounted up tower to provide cost reductions. A novel metal hydride, capable of operating above 760 °C, was developed during the course of this project and thoroughly tested at a lab scale. The material’s hydrogen capacity, reaction enthalpy, thermal conductivity, and cyclic stability were measured. A demonstration test article was built that can store 2kWh of thermal energy and was coupled to Brayton Energy’s CO 2 loop where the performance of the metal hydride under commercial conditions was measured. An integrated model was created that uses the inputs from all the different sub-models in order to return an overall system LCOE using SAM. This project greatly advanced metal hydride based thermochemical energy storage technology and demonstrated its use. Previously there were no metal hydrides which were capable of operating at the proposed temperature limits (760°C), there is now a high temperature metal hydride with documented performance/stability and a path for low-cost production. Additionally, the metal hydride was tested at a scale >650x larger than what had previously been done in the lab. While not at commercial scale, it was an excellent demonstration of the technology and provided knowledge that can be leveraged for other applications.

08 HYDROGEN↗

LLE Diagnostic Resource Team for Innovative Fusion Concepts (Final Report)

The LLE Diagnostic Resource Team for Innovative Fusion Concepts provided travelling neutron diagnostics, consultancy on neutron diagnostics, and consultancy on tritium handling to fusion companies. An existing neutron detector was recalibrated for low yields and two detectors were built based on designs proven on the Omega Laser Facility. The three detectors allow measurements over a wide range of yields (from 10 to 1E7 incident neutrons). The detectors were calibrated for DD neutrons on a dedicated OMEGA shot day. Neutron detectors from the company MIFTI were also calibrated on OMEGA. MIFTI is currently using their detectors and two of our detectors on staged Z-pinch experiments at UCSD. The Team acted as consultants for the development of a liquid scintillator array to detect neutrons from muon induced fusion by NK Labs. Segments of NK Labs’ detector were tested at the LLE using radioactive sources and a DD neutron generator. The Team also acted as consultants for the design of a tritium handling system for NK Labs. A new type of neutron spectrometer was designed and built, and has completed preliminary testing.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Stirred-Reactor Coupon Analysis: An International Round Robin Study

The objective of this task was to determine the precision of the SRCA technique when used to determine the dilute condition corrosion rate. To this end, an interlaboratory round robin study was conducted per the instructions in ASTM Practice E691 to measure the precision with which the SRCA test method can be conducted. Twelve independent labs from eleven different institutions each evaluated four glass compositions in three different conditions. The ASTM procedures recommend at least 6 labs participate in a round robin testing the same 3 materials in the same conditions to determine precision. In this case, 12 labs each performed 12 independent tests. This was only possible thanks to the multi-glass testing capability of the SRCA test. A total of 108 duplicate pairs were used to calculate the repeatability of the tests, with the same glass tested in the same vessel, producing as identical conditions as possible for the replicates. These test results were quite tightly clustered, with a median difference from the average value of the pair of only 2.9%. Based on the calculations outlined in ASTM E177-20 and a measured standard deviation of 4.74%, the intralaboratory repeatability limit (r) was calculated to be within 13.3% of the expected value with 95% confidence level. The reproducibility limit (R) of the test was examined using all 277 data points from the round robin. Because of the differences in dissolution rates due to pH variability and intrinsically for the 12 conditions tested, the reproducibility limits for each condition and overall were calculated from the percent relative residual value for each test. The SRCA test is expected to be reproducible within 64% of the expected value with a 95% confidence level.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

PRESERVATION OF THE HIGH QUALITY FACTOR AND ACCELERATING GRADIENT OF Nb3Sn-COATED CAVITY DURING PAIR ASSEMBLY

Two CEBAF 5-cell accelerator cavities have been coated with Nb3Sn film using the vapor diffusion technique. One cavity was coated in the Jefferson Lab Nb3Sn cavity coating system, and the other in the Fermilab Nb3Sn coating system. Both cavities were measured at 4 K and 2 K in the vertical dewar test in each lab and then assembled into a cavity pair at Jefferson Lab. Previous attempts to assemble Nb3Sn cavities into a cavity pair degraded the superconducting properties of Nb3Sn-coated cavities. This contribution discusses the efforts to identify and mitigate the pair assembly challenges and will present the results of the vertical tests before and after pair assembly. Notably, one of the cavities reached the highest gradient above 80 mT in the vertical test after the pair assembly.

Eremeev, G.V.↗

Preservation of the High Quality Factor and Accelerating Gradient of Nb3Sn-coated Cavity During Pair Assembly

Two CEBAF 5-cell accelerator cavities have been coated with Nb3Sn film using the vapor diffusion technique. One cavity was coated in the Jefferson Lab Nb3Sn cavity coating system, and the other in the Fermilab Nb3Sn coating system. Both cavities were measured at 4 K and 2 K in the vertical dewar test in each lab and then assembled into a cavity pair at Jefferson Lab. Previous attempts to assemble Nb3Sn cavities into a cavity pair degraded the superconducting properties of Nb3Sn-coated cavities. This contribution discusses the efforts to identify and mitigate the pair assembly challenges and will present the results of the vertical tests before and after pair assembly. Notably, one of the cavities reached the highest gradient above 80 mT in the vertical test after the pair assembly.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Preservation of the High Quality Factor and Accelerating Gradient of Nb3Sn-coated Cavity During Pair Assembly

Two CEBAF 5-cell accelerator cavities have been coated with Nb3Sn film using the vapor diffusion technique. One cavity was coated in the Jefferson Lab Nb3Sn cavity coating system, and the other in the Fermilab Nb3Sn coating system. Both cavities were measured at 4 K and 2 K in the vertical dewar test in each lab and then assembled into a cavity pair at Jefferson Lab. Previous attempts to assemble Nb3Sn cavities into a cavity pair degraded the superconducting properties of Nb3Sn-coated cavities. This contribution discusses the efforts to identify and mitigate the pair assembly challenges and will present the results of the vertical tests before and after pair assembly. Notably, one of the cavities reached the highest gradient above 80 mT in the vertical test after the pair assembly.

43 PARTICLE ACCELERATORS↗

Manufacturing the Harmonic Kicker Cavity Prototype for the Electron-Ion Collider

High-bunch-frequency beam-separation schemes, such as the injection scheme proposed for the Rapid Cycling Synchrotron at the Electron-Ion Collider, demand rise and fall times an order of magnitude below what can realistically be accomplished with a stripline kicker. Nanosecond-time-scale kick waveforms can instead be obtained by Fourier synthesis in a harmonically resonant quarter-wave radio-frequency cavity which is optimized for high shunt impedance. Originally developed for the Jefferson Lab Electron-Ion Collider (JLEIC) Circulator Cooler Ring, a hypothetical 11-pass ring driven by an energy-recovery linac at Jefferson Lab, our high-power prototype of such a harmonic kicker cavity, which operates at five modes at the same time, will demonstrate the viability of this concept with a beam test at Jefferson Lab. As the geometry of the cavity, tight mechanical tolerances, and number of ports complicate the design and manufacturing process, special care must be given to the order of the manufacturing steps. We present our experiences with the manufacturability of the present design, lessons learned, and first RF test results from the prototype.

Overstreet, S. A.↗

Manufacturing the Harmonic Kicker Cavity Prototype for the Electron-Ion Collider

High-bunch-frequency beam-separation schemes, such as the injection scheme proposed for the Rapid Cycling Synchrotron at the Electron-Ion Collider, demand rise and fall times an order of magnitude below what can realistically be accomplished with a stripline kicker. Nanosecond-time-scale kick waveforms can instead be obtained by Fourier synthesis in a harmonically resonant quarter-wave radio-frequency cavity which is optimized for high shunt impedance. Originally developed for the Jefferson Lab Electron-Ion Collider (JLEIC) Circulator Cooler Ring, a hypothetical 11-pass ring driven by an energy-recovery linac at Jefferson Lab, our high-power prototype of such a harmonic kicker cavity, which operates at five modes at the same time, will demonstrate the viability of this concept with a beam test at Jefferson Lab. As the geometry of the cavity, tight mechanical tolerances, and number of ports complicate the design and manufacturing process, special care must be given to the order of the manufacturing steps. We present our experiences with the manufacturability of the present design, lessons learned, and first RF test results from the prototype.

Overstreet, S. A.↗

Initial ASME code rule analysis on Simple and Full assessment

ASME & ASTM codes present simple and full assessment methodologies to qualify nuclear grade graphite components. This report explains the theory behind the statistical portion of the codes and describes the issues discussed in a 2020 workshop in the simple assessment, as well as the full assessment. The methodology for the full assessment was developed by Hindley []. He used a validation methodology to match the experimental average failure load of test specimens from several geometries to the calculated 50% POF load to tune the grouping criteria parameters based on an RMSE penalty function. The grouping criteria consists of a minimum volume to satisfy the weakest link theory of the Weibull distribution and a minimum stress range parameter. Hindley’s work found a minimum link volume of 10 times the grain size and a stress range parameter of 7% [satisfy the validation requirements. Several studies found that the link volume of 10 times the grain size was not satisfactory for the volume grouping criteria for graphite grades with fine grains. ASME 2021 code adopted a new volume grouping criteria based on fracture toughness for calculation of the process zone volume. However, errors were found in the ASME 2021 code process zone volume equation and the question is now open as to what volume grouping criteria is satisfactory. This report presents results from sensitivity studies that were done to evaluate the volume grouping criteria effect on the full assessment POF. This report also presents results from sensitivity studies on other aspects of the code that affect the POF, the mesh size and the choice of the Weibull threshold parameter. All three sensitivity studies: the volume grouping criteria, the mesh size, and the threshold parameter choice are found to affect the component qualification decision for components of structural reliability class 1 (SRC-1). The sensitivity analysis results are presented in the body of the report for NBG-18, which is the same grade of graphite as Hindley used in his thesis. Results from NBG-17, IG-110, 2114, and PCEA are presented in the Appendix. For NBG-18, it was found that increasing the threshold increases the POF, finer meshes result in higher POFs, and that smaller link volume requirements lead to higher POFs (which is inconsistent with Hindley’s findings). This report proposes a new validation study similar to Hindley’s []. The purpose of the new validation study is to tune the threshold, mesh size and grouping criteria based on results from multiple grades of graphite, including finer grain graphites T220 (1-3 microns) and NG-CT-50 (5 microns). The test specimens will be broken at 3 labs, such that we can measure between lab measurement variability, with at least 5 test specimens per lab such that the within lab uncertainty can also be measured. Hindley’s validation method tried matching the average experimental load with the median. The future study will attempt to match failures at lower percentiles, which would be closer to the SRC POF limit. We are currently looking into what geometries make sense and the best method to measure multi-axial stress states. These design decisions are still being set.

36 MATERIALS SCIENCE↗

Insulation Coordination Design for Grid-Connected Solid-State Transformers

The deployment of solid-state transformers (SSTs) in medium-voltage (MV) distribution systems is facing various challenges, especially the challenge of insulation coordination design against grid-originated lightning impulses. In this article, two challenges in existing insulation coordination designs for grid-connected SSTs are identified. One challenge is the mismatch between metal-oxide varistor (MOV) protective levels and SST insulation strength, the other challenge is the incompatibility of standard impulse test on SST protective structures. To address the MOV selection challenge, a novel lightning protection scheme is designed to protect a single-stage SST where the semiconductor modules are directly exposed to external lightning impulses. Here, the in-lab lightning impulse tests are performed to verify the overvoltage attenuation performance of the prototyped lightning protection scheme. To address the impulse test challenge, the surge withstand capability of the protected SST is comprehensively evaluated with a complete set of insulation coordination design procedures beyond the basic insulation level (BIL) test. After these two challenges are addressed, a discussion is presented on substituting conventional transformers with the protected SSTs into insulation-coordinated distribution systems to facilitate the field deployment of SSTs.

solid-state transformer (SST)↗

Additive Manufacturing Case Study Test Report

Sandia National Labs collaborated with Oak Ridge National Laboratory on a case study examining additive manufacturing opportunities for Geothermal applications. The study focused on designing components with improved performance characteristics that cannot be fabricated conventionally. A rotor for a downhole motor was chosen based on the potential for improving its rotational dynamics. Topology optimization was used as a design method to reduce the rotational inertia of the part while preserving sufficient rotational stiffness to transmit the torque required for the drilling application. The optimization resulted in a nearly 50% reduction in polar moment of inertia while maintaining other desired performance characteristics. The design developed using the topology optimization approach was fabricated using additive manufacturing and cannot be fabricated conventionally.

15 GEOTHERMAL ENERGY↗

Characterization of an electrically conductive proppant for fracture diagnostics

Fracture diagnosis with electromagnetic (EM) and electrical tools requires proppants with high electrical conductivity and mechanical strength. Lab measurements of the electrical and hydraulic conductivity of proppants are critical for selecting the best candidates. Such measurements greatly benefit simulations, field tests, and the ultimate application of such proppants in the field. To that end, a new lab protocol is developed for measuring the electrical and hydraulic conductivity of proppants. The lab setup, which mainly includes a resistivity core holder and a Hassler sleeve core holder, allows for simulation of realistic pressure and temperature conditions when making measurements. Petroleum coke (PC) is proposed as a candidate proppant because of its widespread availability and low cost. Lab measurements show that the effective electrical conductivity of pure PC in a model fracture is approximately 5000 S/m, under a closure stress greater than [Formula: see text] (4000 psi). When PC is mixed with sand, the effective electrical conductivity of the mixture decreases with an increasing weight percentage of sand. Although sand degrades the contact between PC particles, the electrical conductivity stays reasonably high (approximately 1700 S/m) when 50% sand is added. Hydraulic conductivity measurements show that when a fracture is propped with pure PC, the measured fracture conductivity is greater than [Formula: see text] ([Formula: see text]) (dimensionless fracture conductivity greater than 100 for a shale with [Formula: see text] or 100 nD permeability) under a confining pressure of [Formula: see text] (6000 psi). This means that a fracture propped with PC is infinitely conductive in a typical shale formation. When sand is added, the fracture’s hydraulic conductivity becomes even higher, which clearly shows PC’s ability of sustaining high stresses. The proposed protocol provides a robust and effective method that can be generalized for lab testing for other candidate proppants. The data presented clearly show that PC has the potential for field-scale applications in EM hydraulic fracture diagnostics.

Geochemistry & Geophysics↗

Flexible FlueCO2

Carbon dioxide (CO2) emission reductions remain a significant challenge on the path to clean energy. There are increasing legislative, social, and environmental factors motivating CO2 emissions reduction from power plants with carbon capture and storage (CCS). CCS in natural gas combined cycle (NGCC) power plants is critical to achieve a net-zero carbon electricity grid. Enhanced 45Q tax credits provide new incentives, but currently available technologies are unable to profitably operate in grids with deep variable renewable penetration which require flexible NGCC operation. Luna Labs has developed the FlueCO2 membrane to enable a profitable NGCC-CCS process. The FlueCO2 membrane couples steam transport across the membrane to CO2 transport in the opposite direction, enabling high capture efficiencies and low energy costs even at low CO2 concentrations. The dual-phase membrane can operate in the range of typical flue gas temperatures and pressures and does not require temperature or pressure cycling. Luna Labs’ FlueCO2 technology enables flexible and profitable operation of NGCC plants with lower capital investment and impact on electricity prices. In this Phase 1 project, Luna Labs utilized experimental testing, modeling, process simulation, and standardized costing methodologies to evaluate the techno-economic value of a 650 MW greenfield NGCC plant with FlueCO2 (NGCC-FlueCO2). Key design requirements for operation were established and plant performance under load-leveling conditions was validated through computational fluid dynamics and process modeling. Luna Labs developed a dynamic modeling tool which modeled plant operational modes across a variety of tax structures and electricity pricing scenarios to project the overall Net Present Value (NPV) of the NGCC-FlueCO2. FlueCO2 minimizes the impact of CCS integration on plant operation by integrating directly into the NGCC heat recovery steam generator (HRSG). By tapping into the plant’s low-pressure (LP) steam, operators can divert LP steam to the greenfield NGCC and/or CCS process in response to dynamic markets. Since FlueCO2 will not significantly affect HRSG (or NGCC) operation, CCS only turns off during peak power demand (>$250/MWh). Under baseload conditions, FlueCO2 lowers the capital (37%), energy (36%) and carbon capture (<$40/tonne) costs and can increase the overall plant lifetime NPV by approximately ~$1B in comparison with NGCC solvent-based capture reference cases (NETL Case 31B). Luna Labs has shared its costing tools with several interested partners and customers, which follows a generalizable approach to costing analysis.

Kelly, Jesse↗

Thermocouple Testing in Support of the AGR-5/6/7 Experiment

This report documents thermocouple testing performed in IRC Lab C-15 over a period of seven years. This testing supported selection and characterization of the thermocouple set used in the AGR-5/6/7 experiment. The following summary was taken directly from the report. Temperature measurement is a challenging aspect of very high temperature irradiation experiments because commonly used high-temperature commercial thermocouples such as platinum-rhodium (Types S, R, and B) and tungsten-rhenium (Type C), suffer dramatic drift because of neutron-induced transmutation. As a result, these types of thermocouples, which are used routinely for industrial temperature measurements outside of reactors, are used only in very special circumstances for reactor experiments. Conversely, because of their low neutron cross-sections, Type N thermocouples are affected to only a limited extent by neutron irradiation. However, the use of these nickel-based thermocouples is limited when the temperature exceeds 1050°C due to drift arising from minor alloying elements migrating from the thermocouple's metal sheath to the thermoelements. This change in the composition of the thermo-elements results in significant decalibration of the signal. The issues described above were recognized during the early planning stages of the final AGR experiment (designated AGR-5/6/7), and a thermocouple furnace testing program was performed over a seven-year period (2014-2019, 2021) to first select and then characterize the best thermocouple set for the high temperature regions of the AGR-5/6/7 irradiation experiment. The calculated temperature range of the AGR-5/6/7 experiment was 600–1500°C. For temperatures below 1000°C standard Type N thermocouples were deemed adequate. The furnace testing campaign identified two thermocouple types suitable for measuring temperatures above 1000°C, a Mo/Nb thermocouple developed at INL called HTIR-TC, and a Type N thermocouple developed by Cambridge University (called herein Cambridge Type N), which featured a custom high nickel alloy sheath. One of the original goals of the furnace testing program was to identify a thermocouple capable of low drift operation near the peak temperature expected in AGR-5/6/7, i.e., about 1400°C. The HTIR-TC design appeared promising in this regard, however a manufacturing difficulty proved to be a barrier and instead the furnace testing focused on drift performance at 1250°C. The manufacturing difficulty was that the Nb sheaths of the HTIR-TCs experienced extreme embrittlement when heat treated at 1600°C or greater. Heat treatment is needed to stabilize the emf output of this TC type, and the higher the heat treatment temperature the higher the peak temperature of stable operation. Because of the sheath embrittlement the heat treatment temperature had to be lowered to 1450°C resulting in a stable operating temperature of about 1250°C. One of the successes of the furnace testing program was identification of a shortcoming in the heat treatment procedure that had been traditionally used in the production of HTIR-TCs. The shortcoming was that the entire heated length of the HTIR-TC sensor was not being heat treated, but rather only the part of the sensor expected to experience temperatures above 1000°C. The problem manifested itself when the thermocouples were removed from the heat treat furnace and placed in another furnace with a different geometry, their indicated temperatures would be widely scattered, but mostly in the negative direction. The solution was to heat treat the entire heated length of the sensor. Since the deepest immersion depth in the AGR-5/6/7 experiment was about 40 inches, a heat treatment length of 48 inches was used. After this change was implemented, thermocouples which were moved into a new environment with a different temperature profile (i.e., a different furnace), produced accurate temperature measurements. Although assembly of the AGR-5/6/7 experiment was completed in September of 2017 (and irradiation begun in 2018), furnace testing of thermocouples continued in 2018 and 2019. The main purpose of this testing was to establish very long-term drift characteristics of the HTIR and Cambridge Type N thermocouples installed in the experiment. Representative thermocouples from the same lots as those installed in the AGR-5/6/7 experiment were used. Additionally, thermocouples of different designs, (particularly variations on the HTIR-TC design) were "piggy-backed" on this testing program to provide insights for instrumenting future very high temperature irradiation experiments. This two-year testing program demonstrated that HTIR-TCs and Cambridge Type N TCs could operate at 1250°C for up to 10,000 hrs (and in some cases longer) while experiencing negative drifts on the order of 2-4°C/1000 hrs. This performance was considered acceptable given the extreme operating environment the sensors faced.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Cold Spray Additive Manufacturing For New Pipeline Fabrication In Live, Natural Gas Distribution Mains

ULC Technologies (ULC) and the Penn State University Applied Research Lab (PSU ARL) developed a process and approach for rehabilitating live, natural gas distribution pipelines using Cold Spray Additive Manufacturing (CSAM). Robotic inline fabrication of a new pipe will be performed inside a natural gas main without disrupting customers. The material studied was blended with stainless steel which offers corrosion resistance, high strength and compatibility with hydrogen to enable a robust pipeline system that is future proofed. Stainless steel coatings sprayed and tested in the lab showed excellent strength, ductility, and porosity values. ULC initially sought to use methane as the process gas for compatibility with the host pipe, but after evaluating the field and lab challenges, nitrogen was deemed to be more suitable. Early robotic concepts have been developed that indicate technical feasibility. While the technology development originally targeted natural gas distribution mains, market research showed a broader need. Spot repairs performed in natural gas transmission mains may be a more economical approach for reinforcing distribution and transmission mains compared with full pipe-in-pipe rehabilitation. Additive manufacturing offers custom programming, as well as high accuracy and precision. This means custom contours can be manufactured in situ, offering flexibility in the repair solution, such as fabricating internal full circumferential sleeves. The value of the repair can be high at difficult-to-reach locations and in pipes that need reinforcement before the injection of methane-hydrogen blends.

03 NATURAL GAS↗

Advanced Thin Film Core Technology: CIGS Final Technical Report (FTR)

Cu(In,Ga)Se 2 (CIGS) thin-film photovoltaics are a high-efficiency and reliable technology. This project completed research in two important areas and was designed to work collaboratively with industrial partners. Task 1: Alkali Science focused on alkali post-deposition treatments (PDT). PDTs have been instrumental in the dramatic voltage improvements that have moved CIGS device efficiencies from 20% to 23.35% [1]. Based on a survey of CIGS companies at the beginning of the project, the single biggest breakthrough for the CIGS community would be a mechanistic understanding of the role of alkalis in the material system. Significant accomplishments of Task 1: Alkali Science: 1) KF post-deposition treatments were shown to improve lifetime, open-circuit voltage (VOC), and efficiency of industrial partner samples, even when done as a later step, separate from the original CIGS deposition. 2) KF boosted efficiency when incorporated at the end of the third stage of NREL CIGS growth. 3) XPS characterization of CIGS surfaces with and without PDTs led to a proposed mechanism whereby K drives structural transformation at 350 degrees C that is locked in at room temperature even after K is rinsed away. 4) Published recipes for KF and RbF PDTs. Literature to date did not provide enough detail to quickly reproduce experimental results. 5) Identified most important parameters (RbF cell temperature and lamp setpoint temperature) and set boundaries for successful RbF PDTs. The purpose of Task 2: Cell-level Reliability was to overcome the largest challenges to investor confidence and long product lifetime in CIGS-based photovoltaic products: metastability, shading-induced hot spots, and potential-induced degradation (PID). Key findings were made in each of these areas by studying CIGS reliability at the cell level: 1) Published NREL's cell-level reliability testing procedures along with challenges that were encountered while developing them. These were also distributed to the community through an MRS conference presentation. 2) Decreased metastability by adding a CdS hole-injection layer between the CIGS and Zn(O,S) in the device stack. It also improved device performance. Materials other than CdS can be used for the same purpose. 3) Reduced front-glass PID by replacing soda-lime glass with low-Na borosilicate glass. 4) Found that PID depends on leakage current and light/electrical bias. This will help labs avoid test-specific degradation. 5) Discovered that CIGS can suffer from two different types of PID with different mechanisms. Front is slower and leads to shunting ZnO. Back is faster and degrades the p-n junction. 6) Holding cells at open circuit slows PID compared to short circuit. This affects testing protocols for glass/glass modules.

14 SOLAR ENERGY↗

A High-Field Polarized 3 He Target for Jefferson Lab’s CLAS12 Spectrometer

Polarized 3He nuclear targets are invaluable surrogates for polarized neutron targets in spin-dependent scattering studies of the structure of matter. Traditional polarized 3He targets have seen steady improvements and active use over the last three decades, however they have been limited to operation in low magnetic fields. This has precluded their use in spectrometers that utilize high-magnetic-field tracking systems, such as Jefferson Lab's CLAS12 spectrometer. Developments in high-magnetic-field metastability exchange optical pumping of 3He, recently incorporated into the design of a polarized 3He ion source for RHIC and the EIC, could enable a new, polarized 3He fixed target to operate within high fields. Combining high-field techniques with the double-cell cryogenic target design used for the MIT-Bates 88-02 experiment, polarization and target density comparable to traditional polarized 3He targets could be reached while within a high magnetic field environment. We discuss the conceptual design for such a target, show our progress in this target's development, and outline plans for in-beams tests in Jefferson Lab's Hall B.

Maxwell, James↗