Search NASASearch

SEARCH · Search NASA

Results for “Mass Flow Rate”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

353 records · Page 9

Nuclear Structure and Decay Data for A=35 Isobars

Here, this work presents a comprehensive and critical evaluation of experimental nuclear spectroscopic data from reactions and decays for all 11 known nuclides with mass number 35 (Ne, Na, Mg, Al, Si, P, S, Cl, Ar, K, Ca). Recommended values are produced for level energies, spins and parities, half-lives, and radiation properties including energies, branching ratios, and multipolarities of γ rays, as well as characteristics of β radiation decays, based on a rigorous assessment of all available experimental data. Discrepancies among existing results are carefully addressed. This work supersedes earlier full evaluations of A=35 published by 2011Ch48, 1990En08 (also 1998En04 update) and 1978En02.

Sun, Lijie [Michigan State University, East Lansin

Robustness of pairwise kinematic Sunyaev–Zel’dovich effect to optical-cluster-selection bias

The pairwise kinematic Sunyaev–Zel’dovich (kSZ) effect measures both the pairwise motion between galaxy groups and clusters and the amount of gas within them, providing a tracer for cosmic growth. To interpret the cosmological information in the kSZ measurements, it is crucial to understand the optical-cluster-selection bias on the kSZ observables. Line-of-sight structures that contribute to both the optical observable (e.g., richness) and the cosmological signal can induce a correlation between these two quantities at a fixed cluster mass. The selection bias arising from this correlation is a key systematic effect for cosmological analyses. For cosmological observables such as cluster abundance and weak lensing, controlling this selection bias may help explain the tension between the DES-Y1 results and the Planck constraints. In order to test for a kSZ effect equivalent of such a bias, we adopted an alternative mock richness based on galaxy counts within cylindrical volumes along the line of sight. We applied the cylindrical count method to hydrodynamical simulations across a wide range of galaxy-selection criteria, assigning richness consistent with DES-Y1 to the mock clusters. When comparing optically selected clusters to mass-selected halos, we find no significant bias on pairwise kSZ signals, pairwise velocities, or optical depth within our uncertainty limits of approximately 16, 10, and 8%, respectively.

79 ASTRONOMY AND ASTROPHYSICS

Interface Evolutionand Long-Term Performance of NegativeCarbon Fiber Structural Electrodes

Abstract Laminated structural batteries present a transformative solution to reducing weight constraints in electric vehicles. These structural batteries are based on a multifunctional material that incorporates an energy storage function within a carbon fiber-reinforced polymer. Despite the potential of this technology, the intricate morphology of fiber–matrix or electrode–electrolyte interfaces and the impact of long-term cycling at low current rates (C-rates) on these interfaces remain insufficiently understood. This study addresses these critical knowledge gaps by examining the influence of matrix composition on the long-term electrochemical performance of structural battery electrodes and exploring advanced techniques to investigate carbon fiber–matrix interfaces. Localized imaging and X-ray scattering techniques were used to characterize morphological changes at the electrode–electrolyte interfaces by analyzing negative structural electrodes. The findings revealed that the matrix composition influences long-term electrochemical behavior and fiber–matrix interface formation. While the intrinsic properties of carbon fibers largely remain unaffected by long-term cycling, cycling promotes debonding at fiber–matrix interfaces. Nonetheless, residual regions of adhesion persist, underscoring the potential for preserving multifunctionality even under prolonged cycling conditions. These insights advance the understanding of interface dynamics, which is critical for optimizing structural battery technologies.

Chemistry

230Th/234U radiochronometry for uranium materials by alpha spectrometry for nuclear forensics analysis

We have developed an alpha spectrometry method for 230Th/234U radiochronometry to determine the model separation age for uranium materials. This method offers an alternative to the more commonly used, but significantly more resource intensive multi-collector inductively coupled plasma mass spectrometry (MC-ICP-MS) while providing similar accuracy and precision. The development included radiochemical separation of uranium and thorium, calibration of the 232U tracer and the alpha spectrometry measurement. The method was validated by analyzing a certified reference material, CRM 125-A, which is a uranium oxide pellet assay, isotopic, and radiochronometric standard. The results were compared to those obtained by our routine MC-ICP-MS 230Th/234U radiochronometry analysis method to assess the performance parameters for alpha spectrometry compared to the state-of-the-art technique.

Macsik, Zsuzsanna [Los Alamos National Laboratory

Design and fabrication of ion traps for low RF power dissipation

Large surface-electrode ion traps with multiple trapping regions and junctions are a natural approach to scaling trapped ion quantum computers, supporting the connectivity and ion counts necessary for complex quantum algorithms. However, a major hurdle in this scaling is on-chip power dissipation from the applied RF voltage, which increases at a rate between linear and cubic relative to trap size, depending on whether the losses are dielectric or Ohmic. Here, we present two versions of a trap with features designed to reduce both types of RF power dissipation. The first variant contains a raised RF electrode that increases the electrode–ground distance to reduce capacitance. Different DC voltage sources are demonstrated on this trap to show that technical noise before the filter remains the dominant source of voltage noise and therefore motional heating. The second variant additionally includes a method for removing dielectric from beneath the RF electrode to further reduce dielectric losses. These traps were demonstrated at room temperature with 40 Ca + ions. In conclusion, the similar heating rates and heating rate axial frequency dependencies between 2.4 and 3.0 MHz illustrate that this dielectric modification is not detrimental to trap performance.

Sterk, J. D. [Sandia National Laboratories (SNL-NM

Correlating Impacts of Injected Fuels on Carbon Emissions in Blast Furnace with Computational Fluid Dynamics Modeling

A major challenge for steelmaking is the reduction of CO 2 emissions. In this regard, the blast furnace (BF) is critical due to the high associated CO 2 levels. This investigation assesses the impact of tuyere‐injected fuels on BF CO 2 emissions. Specifically, computational fluid dynamics results obtained previously at Purdue University Northwest are analyzed to obtain CO 2 emissions when natural gas (NG), syngas, hydrogen, or hydrogen/NG are injected. CO 2 emissions are compared with those produced when 95 kg of NG/thm is injected. Among these scenarios, the largest CO 2 reduction occurs when 102 kg of syngas/thm (COG feedstock #1) is injected at 973 K, reducing CO 2 by 190.6 kg thm −1 . The largest CO 2 reduction obtained with NG occurs when 130 kg thm −1 is injected at 600 K, reducing emissions by 65 kg thm −1 . H 2 injection also reduces CO 2 , but requires careful adjusting to reach stable operation. For instance, injecting 35 kg of H 2 /thm reduces CO 2 by 52 kg thm −1 . Increasing gaseous injection rates can significantly reduce CO 2 emissions, with fuel preheating providing an addendum, but high injection rates can lead to unstable operation. Furthermore, results show a correlation between CO 2 emissions and average temperature of shaft region for multiple fuels and injection conditions.

Metallurgy & Metallurgical Engineering

Activating magnetite ores for aqueous ironmaking at high current densities

Low-temperature electrochemical cells reducing iron oxides to metal in alkaline electrolytes can support fully electrified steelmaking processes. Previous studies on these cells have primarily focused on high-surface-area hematite, Fe 2 O 3 , reactants whereas attempts to reduce suspensions of magnetite, Fe 3 O 4 —one of the two feedstocks for existing ironmaking reactors—have generally been limited to low rates of reaction (<30 mA cm −2 ). Here, in this study, we control the crystalline domain size of Fe 2 O 3 and Fe 3 O 4 particles in 10 M NaOH electrolytes to study how the nanoscale morphology of oxides controls the rate of electrochemical ironmaking. Rotating-ring disk electrode measurements of Fe 2+ , in situ Raman spectroscopy of the electrode surface, and ex situ electron microscopy were consistent with a hypothesized passivation process at Fe 3 O 4 surfaces that may prevent the continuous formation of soluble intermediates. Sufficiently small (<100 nm diameter) oxide particles yielded Fe partial current densities >160 mA cm −2 , a fivefold increase relative to previously reported rates for Fe 3 O 4 suspensions and comparable to active Fe 2 O 3 . Electron microscopy revealed that electrodeposited films were composed of micron-scale crystalline Fe domains with a porous film of Fe 3 O 4 nanoparticles and supports a model where Fe is grown primarily from soluble Fe 2+ intermediates. Based on these insights, inactive blast-furnace-grade iron-oxides were transformed into high surface area nanoparticles (1.6 to 229.2 m 2 g −1 ) via reprecipitation, leading to a ninefold enhancement in faradaic efficiency and an Fe partial current density of 120 mA cm −2 . When integrated with chlor-iron cells producing reagents for reprecipitation, this approach could lead to a cost-competitive process for electrochemical ironmaking from industrially relevant feedstocks.

TEM

Complex-Valued Intermolecular Coupling Enables Directional Exciton Transport in Excitonic Circuits

Molecular systems capable of directing the flow of excitons are key to the development and optimization of optoelectronic materials. The transport of excitons across multiple molecules is governed by an intermolecular electronic coupling network. In this article, we consider the effects of complex-valued intermolecular electronic coupling on exciton transport. Here, we present a molecular motif capable of generating complex-valued coupling under excitation with circularly polarized light. We use theoretical modeling and simulation to illustrate how complex coupling can be leveraged to drive the rotational flux of excitons in cyclic molecular networks and direct the exciton population in branched molecular networks.

chromophores

Thick graded interfaces increase wear resistance in Ti/TiN nanolayered thin films

Multilayered composites with nanoscale layer thickness incorporating titanium and titanium nitride (Ti/TiN) are used as a model system to study the effects of heterophase interface structure on elastic and plastic deformation, as well as wear behavior. Here, in this work, hardness, modulus, and wear rate under dry reciprocating sliding contact are quantified as a function of Ti-TiN heterophase interfacial nitrogen gradient thickness for Ti/TiN multilayers with 10–80 nm layer thickness. Hardness and modulus are found to be inversely proportional to layer thickness and independent of interface gradient for most specimens. Wear rate is found to be inversely proportional to interface gradient thickness at constant layer thickness, demonstrating that control of nanoscale interface structure is a valid approach to enhancing wear behavior. The materials studied in this work wear comparably or slower than other Ti- and TiN-based composites in the literature, providing a promising avenue for engineering wear-resistant materials for use in industrially relevant applications.

Graded interfaces

Nuclear Safety [Vol. 32, No. 1, January-March 1991]

Nuclear Safety is a review journal that covers significant developments in the field of nuclear safety. Its scope includes the analysis and control of hazards associated with nuclear energy, operations involving fissionable materials, and the products of nuclear fission and their effects on the environment. Primary emphasis is on safety in reactor design, construction, and operation; however, the safety aspects of the entire fuel cycle, including fuel fabrication, spent-fuel processing, nuclear waste disposal, handling of radioisotopes, and environmental effects of these operations, are also treated. Table of Contents for this issue follows. GENERAL SAFETY CONSIDERATIONS: 1 The Safety Review and Approval Process for Space Nuclear Power Sources, G. L. Bennett; 19 Report on the American Nuclear Society International Topical Meeting: "The Safety, Status, and Future of Non-Commercial Reactors and Irradiation Facilities", E. G. Silver; 35 Book Review: Fission Product Transport Processes in Reactor Accidents, Proceedings to the International Centre tor Heat and Mass Processes T. S. Kress; 38 Fast Reactor Technology in the 1990s: A Summary of the 1990 International Fast Reactor Safety Meeting, A. E. Levin; ACCIDENT ANALYSIS: 56 Effects of Chemical Phenomena on LWR Severe Accident Fission Product Behavior, A. P. Malinauskas and T. S. Kress; CONTROL AND INSTRUMENTATION: 65 Technical Note: Safety Parameter Display Systems—10 Years Later, R. J. Eckenrode; 68 Potential Application of Neural Networks to the Operation of Nuclear Power Plants, R. E. Uhrig; DESIGN FEATURES: 80 Twenty-First DOE/NRC Nuclear Air-Cleaning Conference, R. R. Bellamy, D. W. Moeller, and M. W. First; 91 Impact of an Apparent Radiation Embrittlement Rate on the Life Expectancy of PWR Vessel Supports, R. D. Cheverton, G. C. Robinson, W. E. Pennell, and R. K. Nanstad; ENVIRONMENTAL EFFECTS: 103 Technical Note: The Impact of Offsite Factors on the Safety Performance of Small Nuclear Power Plants, Yu. D. Baranaev and A. N. Viktorov; WASTE AND SPENT FUEL MANAGEMENT: 109 Activities Related to Waste Management, Compiled by E. G. Silver; OPERATING EXPERIENCES: 118 Reactor Shutdown Experience, Compiled by J. W. Cletcher; 121 Selected Safety-Related Events, Compiled by G. A. Murphy; 123 Operating U.S. Power Reactors, Compiled by E. G. Silver; RECENT DEVELOPMENTS: 140 General Administrative Activities, Compiled by E. G. Silver; 150 Reports, Standards, and Safety Guides, D. S. Queener; 155 Status of Power-Reactor Licensing Activities, Compiled by E. G. Silver; 157 Proposed Rule Changes as of Sept. 30, 1990; ANNOUNCEMENTS: 79 MIT Offers Summer Program on Nuclear Power Reactor Safety; 108 Harvard School of Public Health Offers Several Short Courses; 139 Short Course and Workshop on Nuclear Criticality Safety at University of New Mexico; 160 SCK/CEN Announces Training Course on Emergency Planning and Response; 161 The Authors; 164 Indexes to Nuclear Safety, Volume 31

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS

Field Validation of Thermoelectric Generation System at Holcim Cement Plant in Alpena, Michigan

Executive Summary Project Background The Industrial Technology Validation (ITV) program aims to identify and demonstrate the performance of new, emerging, and underutilized energy-saving technologies in the industrial sector to help inform decisions to help accelerate their commercialization and deployment, as well as to help make industries more competitive. This ITV demonstration evaluated a thermoelectric generation (TEG) technology at a cement plant, aiming to reduce energy demand in the cement industry. A median cement plant consumes 5.73 million British thermal units per ton of clinker production (resulting in 0.838 metric tons of carbon dioxide [CO₂] emissions per ton of clinker) (Boyd and Zhang 2011, EPA 2021), equivalent to approximately 6.9 trillion British thermal units (TBtu) per year in energy consumption at a cement plant producing 3,300 tons of clinker per day.¹ Collaborating with Holcim, Advanced Thermovoltaic Systems (ATS) developed and deployed a pilot-scale thermoelectric power system to efficiently capture and convert waste heat to electricity. The system leverages the Seebeck effect to convert temperature differences on two sides of semiconductor cartridges into electrical power (ScienceDirect, n.d.). This generation is realized with minimal moving parts compared to existing waste-heat-to-generation solutions and allows capture from heat sources with temperatures as low as 150°C. This project aimed to validate a scalable solution applicable for capturing medium-temperature waste heat, including ambient losses from other high-temperature processes, and high-temperature sources less suitable for other waste-heat-to-power solutions. By recovering this otherwise wasted heat, this project intends to validate improvements to overall process efficiency through reduction in purchased electricity, thereby reducing operational costs while enhancing resiliency and competitiveness. Description and Scope This study evaluated the performance of a TEG system from ATS as a solution to convert waste heat into useful power at a Holcim cement plant in Alpena, Michigan. This plant is a fully integrated cement plant that has been operating since 1907. The facility operates continuously (24/7/365) with approximately 250 employees and five long dry kilns, yielding a total production capacity of 7,852 tons of cement per day (EPA 2023). Currently, the Alpena plant uses waste heat boilers to convert waste heat from the exhaust of each kiln into steam, which drives steam turbine generators. The ATS TEG is being evaluated for its potential to supplement the steam turbines by capturing the remaining lower grade heat. This technology is also being considered for other Holcim plants where steam turbines are not a viable option. ATS installed a pilot-scale TEG unit with an array of 582 individual thermoelectric semiconductor cartridges, of which 573 were operational. The cartridges are sandwiched between 48 hot plates and 49 cold plates. Each cartridge is designed to generate 20 watts (W) of gross power at a hot-side temperature of 240°C and cold-side temperature of 20°C. As such, the total gross generation capacity of the installed system is 11.5 kilowatts (kW) at design conditions. The system configuration for the evaluation was designed to prioritize convenience of installation and minimize disruption to production at the site, while ensuring that the heat required can be obtained for evaluating the TEG system at various operational conditions. To accomplish this, a portion of the steam supplied to Alpena’s steam turbine generation system was diverted to be used as the heat source for the TEG system, while water was supplied to the cold side of the system from nearby Lake Huron. This configuration was designed for the evaluation of the pilot-scale system to assess the performance at different conditions. A commercial-scale system will likely vary from the pilot system depending on typical configurations, including both scale and application. Future commercial applications of the ATS system would involve integrating the system into the exhaust from kiln preheaters, clinker coolers, or radiant heat capture from kiln shells for the heat source. For the cold source, a range of cooling solutions can be considered, including a mechanical cooling system, depending on the location and the application. To increase the generation capacity for commercial applications, the technology provider is working toward developing a commercial-scale TEG system, which would combine multiple TEG units (each similar in design to the pilot system) together. The scope of this evaluation includes the pilot-scale TEG system and all impacted equipment including pumps, controllers, and power handling equipment. Study Objectives The evaluation's goal was to assess the potential of the ATS TEG system to generate useful electrical power by capturing waste heat from cement production kilns. The objectives of this study are to evaluate and verify the following claims made by ATS regarding the pilot-scale system installed at the Holcim Alpena plant. The following design parameters and claims are also outlined in Table ES- 1 and Table ES- 2: • Gross Power: The thermoelectric system converts heat into power to create gross power, the total measured power generated by the system. The 573 active cartridge pilot-scale system is expected to generate 11.5 kW of gross power at the designed hot-side temperature of 240°C and cold-side temperature of 20°C. Power production is dependent on the temperature difference between the heat source (ultimately from the waste heat) and cold temperature supply source. • Net Power: The net power is the total usable power provided to the site by the TEG system after deducting parasitic power loads from the gross generated power. Supplementary equipment is required to operate the TEG system including pumps, controllers, and, in certain anticipated applications, mechanical cooling, which introduce parasitic loads to system operation. After deducting the parasitic loads from the gross power generation, ATS anticipates achieving a net power generation of 7.5 kW from the pilot-scale system. • Thermal Efficiency: The thermal efficiency is the percent of the total heat transferred to the TEG system that is converted to gross power. Historically, TEGs have a thermal efficiency of 2%–5% (DOE 2008). Prior industrial-scale TEG systems, such as the E1 TEG offered by Alphabet Energy, operated at an efficiency of 2.5% (Lamonica, 2014). ATS anticipates achieving an average efficiency of 4.8% or higher in converting heat energy to usable electricity. • Cartridge Performance: The TEG system comprises 573 active individual semiconductor cartridges, each of which generates a portion of the total power. Cartridge optimization and selection is an important design consideration for potential future TEG system design performance. Therefore, understanding the distribution of gross power and efficiency within the pilot system is vital to understanding what is achievable. At a design hot-side temperature of 240°C and cold-side temperature of 20°C, ATS anticipates a cartridge performance of 20 W of gross power per cartridge at an efficiency of 4.8% per cartridge. In addition to evaluating the claimed performance of the TEG pilot-scale unit, the study estimated the potential annual impacts of a scaled-up commercial system used to capture kiln waste heat over annual operations. The evaluation estimated the gross and net annual electric generation achievable by capturing heat from the two proposed tap-in points: the kiln exhaust and the clinker cooler exhaust; see Section 2.1 for details. Two use cases were examined: • Holcim Alpena: The Holcim Alpena site consists of long dry kilns with superheater boilers, which differs from the rest of Holcim’s cement plant portfolio and results in lower waste heat temperatures. The study estimates gross and net annual generation using the superheater boiler exhaust and clinker cooler exhaust, based on 2023 operational data. • Typical Installation: Common cement plants have preheater kilns with higher exhaust temperatures than Holcim Alpena across a range of production rates. The study estimates gross and net annual generation using the preheater exhaust and clinker cooler exhaust, with a sensitivity analysis to account for the typical range of preheater exhaust temperatures, clinker cooler exhaust temperatures, and clinker production rates. Methodology The evaluation methodology followed a measurement and verification (M&V) strategy based on the International Performance Measurement and Verification Protocol Option B through comprehensive measurements and analyses of the affected systems. Evaluation data was collected from March 9 to March 11, 2024, the test period of the pilot TEG system. During the test period, in coordination with the ITV team, the ATS team adjusted system operations to capture the range of variability expected for each of the variables pertinent to performance of the system. The methodology consisted of two parts: evaluating the performance of the pilot unit's TEG system and estimating the annual TEG impact in terms of gross and net power based on a given waste heat profile. First, the evaluation of the thermoelectric generation performance of the pilot unit relative to the claims was performed by analyzing the collected test data. Gross power of the pilot TEG system was directly measured. Net power was determined by deducting the measured parasitic power from the gross power. The gross power generation was compared to heat transferred to the system by the working fluid (which was heated by steam generated from the kiln waste heat) to calculate the thermal efficiency achieved by the system. Performance of individual semiconductor cartridges within the pilot array was also assessed in terms of measured gross cartridge power and calculated cartridge thermal efficiency. The second part of the evaluation estimated the annual TEG impacts in terms of gross power and net power (calculated from the difference between gross power and parasitic power). This analysis comprised development of mathematical regression models for gross power and parasitic power, with assessment of each model’s goodness-of-fit characteristics to ensure satisfaction of statistical requirements. The models predicted the gross power generation, the parasitic load based on the temperature difference between the hot working fluid and the cold-side fluid (cold water from Lake Huron) entering the system, the volumetric flow rate of the cold-side fluid at the inlet, and the volumetric flow rate of the hot working fluid at the inlet. The annual impact analysis considered a theoretical commercial-scale system sized to capture the available waste heat at a cement plant, consisting of linked pilot-scale units that receive heat from a theoretical gas-to-working-fluid heat exchanger. To estimate annual impacts at the Alpena plant, the gross power and parasitic power regression models were applied to the arrays in the theoretical commercial-scale system. The heat supplied to the unit was calculated based on the kiln run time, annual production, kiln exhaust waste heat, and clinker cooler waste heat derived from 2023 Holcim Alpena kiln operational data. Net power impacts were calculated by deducting the resulting parasitic power from the estimated gross power. Inputs for the model were generated from a combination of hourly data, assumed design considerations for TEG system scale-up from the pilot-scale unit, and assumptions regarding TEG system operations. This analysis was then used as the basis for estimating annual impacts of typical TEG installation at cement plants, by applying sensitivity analyses to key kiln operational characteristics including kiln preheater exhaust temperatures, cooler clinker exhaust temperatures, and plant daily production rates across a range of expected values. Project Results/Findings Table ES- 2 and Table ES- 2 provide a summary of the operating conditions and evaluation results compared to the stated claims from the technology provider. Key takeaways include: • Gross Power: The peak gross power achieved during the testing period was 10.0 kW, compared to the 11.5 kW expected for 573 active cartridges. The claimed gross power was associated with a target hot side of 240°C; however, the system only received a maximum hot-side mean plate temperature of 212°C during the testing period. • Net Power: The pilot-scale unit exceeded the claims for net power, achieving a peak of 7.7 kW net compared to a claim of 7.5 kW. One factor contributing to the higher achieved net power is the relatively high water pressure available through Lake Huron. The pilot TEG system did not require cold-side pumps during the test, whereas most installations would. This reduced the parasitic loads on the system, ultimately contributing to higher net power relative to the gross power. • Thermal Efficiency: The pilot-scale unit outperformed the claimed efficiency, achieving a peak system efficiency of 5.0% thermal efficiency compared to the stated 4.8%. • Cartridge Performance: To compare cartridge performance against claims, the study focused on the third day of testing, which aimed for conditions closest to the design specifications, with a hot side of 240°C and cold-side exit temperature of 6.4°–30°C. On this day, the mean gross power observed in the cartridges within the TEG array was 18.1 W/cartridge, and the peak performance was 34.7 W/cartridge. The estimated mean cartridge efficiency was 5.2%, and the estimated efficiency at peak gross cartridge power was 10%. The regression models developed for gross power generation and parasitic loads were used to estimate the generation impact for given heat input to the TEG from the working fluid (captured from the waste heat) and from the cold loop (Lake Huron) on an hourly basis for a year of operation. Based on this analysis, installation of a commercial-scale TEG system at the Holcim cement plant in Alpena, Michigan, with a waste heat exchanger of 0.85 effectiveness, would generate up to 391 kW of net power, translating to between 920,000 and 1,800,000 kilowatt-hours (kWh) in net electricity per year. Based on typical grid emissions for Alpena, this would avoid estimated net emissions by 752 metric tons of CO₂ annually.² The sensitivity analysis estimated that typical TEG system installations at cement plants could generate an average of 56–1,040 kW of net power, or between 488,000 and 9,110,000 kWh of net energy. This generation potential is most significantly affected by plant production rates and also influenced by preheater and clinker cooler exhaust temperatures. Applying the national average emission rate, typical commercial-scale installations at Holcim plants are projected to avoid between 182 and 3,401 metric tons of CO₂ annually per site. Table ES- 3 shows a summary of the estimated annual impacts.³ While parasitic loads are significant and vary by application, this analysis assumed the use of heating loop pumps and access to Lake Huron as a cold sink. This setup assumed no need for cooling loop pumps due to the available water pressure at the test site. Applications that require cooling towers or additional equipment are likely to experience higher parasitic loads. Therefore, the study’s estimates are most applicable to scenarios with similar parasitic load configurations—namely, access to a high-pressure cold sink. Applicability to other locations may be limited, as differing conditions could necessitate additional pumps and cooling systems, potentially impacting performance significantly.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI

Comparing Thermal Neutron Scintillators for Use With SiPM-Readout Detectors

Scintillator-based thermal neutron detectors for scientific scattering facilities offer an effective combination of large-area coverage and good spatial resolution. At Oak Ridge National Laboratory, silicon photomultiplier (SiPM)-readout Anger cameras using 6 Li glass scintillators have been developed, but the spatial resolution of these detectors is limited by the relatively low light yield of the glass. Recently, several brighter scintillator compositions with sufficient 6 Li concentration have emerged as promising candidates for higher-resolution imaging. Here, in this work, we evaluate five scintillator materials: GS20, LiF/ZnS:Ag, LiF/ZnO:Zn, LiI:Eu, and Cs 2 LiYCl 6 :Ce, each mounted on a SiPM Anger camera. For each scintillator, the neutron detection efficiency, spatial resolution, and count rate capabilities were measured and compared. Each of the new compositions achieved a spatial resolution better than 0.5 mm, compared to 0.66 mm for GS20, with LiI:Eu reaching the best value of 0.32 mm. Although these compositions improve the spatial resolution of the Anger camera, their longer pulse decay times limit their use in high count rate applications, and the camera’s hardware must be optimized for the different properties of the new scintillators.

Neutron detectors

Combined dark matter search towards dwarf spheroidal galaxies with Fermi -LAT, HAWC, H.E.S.S., MAGIC, and VERITAS

Dwarf spheroidal galaxies (dSphs) are excellent targets for indirect dark matter (DM) searches using gamma-ray telescopes because they are thought to have high DM content and a low astrophysical background. The sensitivity of these searches is improved by combining the observations of dSphs made by different gamma-ray telescopes. We present the results of a combined search by the most sensitive currently operating gamma-ray telescopes, namely: the satellite-borne Fermi -LAT telescope; the ground-based imaging atmospheric Cherenkov telescope arrays H.E.S.S., MAGIC, and VERITAS; and the HAWC water Cherenkov detector. Individual datasets were analyzed using a common statistical approach. Results were subsequently combined via a global joint likelihood analysis. We obtain constraints on the velocity-weighted cross section 〈σv〉 for DM self-annihilation as a function of the DM particle mass. This five-instrument combination allows the derivation of up to 2-3 times more constraining upper limits on 〈σv〉 than the individual results over a wide mass range spanning from 5 GeV to 100 TeV. Depending on the DM content modeling, the 95% confidence level observed limits reach 1.5×10 -24 cm 3 s -1 and 3.2×10 -25 cm 3 s -1 , respectively, in the τ + τ - annihilation channel for a DM mass of 2 TeV.

79 ASTRONOMY AND ASTROPHYSICS

Development of a high fidelity CFD model for solvent evaporation and transport in porous structure during battery electrode drying

An efficient battery manufacturing process is the key to the mass production of Electric Vehicles (EV), in which drying is one of the most energy-intensive steps significantly influencing the battery cell performance. An accurate 3D CFD model for drying is essential for predicting the drying mechanism and optimizing its parameters. By optimizing the drying process, it is possible to reduce energy consumption and cost during battery manufacturing, minimize binder loading and maximize active material loading to achieve superior electrochemical performances and facilitate wider and faster public adoption of EV. This project aims to optimize the drying process during electrode manufacturing by leveraging high-fidelity, porous electrode simulations for solvent evaporation. By optimizing this process, we seek to reduce energy consumption during battery manufacturing, while minimizing binder loading and maximizing active material loading, with the overall goal of enhancing electrical vehicle performance.

Horner, Jeffrey Scott [Sandia National Laboratorie

Intrinsically Conductive {pi}‑d Conjugated Layers with Co–N4 Active Sites for Efficient Nitrate Electrocatalysis and Zinc-Nitrate Batteries

Electrochemical synthesis of ammonia from nitrate has been extensively investigated as a potential alternative to the energy-intensive Haber-Bosch process. This approach not only operates under ambient conditions but also simultaneously removes nitrate contaminants while producing ammonia as a value-added product. However, the ongoing quest lies in designing an efficient electrocatalyst that achieves a high ammonia yield rate, high selectivity, and long-term stability. Herein, we report the outstanding performance of a Co–N4 coordinated π-d layered Co3(HITP)2 (HITP = 2,3,6,7,10,11-hexaiminotriphenylene) in nitrate electrocatalysis. The unique combination of abundant Co–N4 active sites and superior electrical conductivity enables significant electrocatalytic activity, delivering a maximum ammonia yield rate of 56.8 mg cm–2 h–1 at −0.8 V vs RHE and a Faradaic efficiency of ∼91% at −0.4 V vs RHE. Mechanistic analysis reveals that alkaline conditions accelerate water dissociation to generate adsorbed hydrogen intermediates (H*), which are utilized by Co–N4 sites to drive the stepwise hydrogenation of nitrate to ammonia while suppressing competing hydrogen evolution reaction (HER) pathways. Furthermore, integration of this catalyst into a zinc-nitrate battery resulted in a maximum power density of 5.3 mW cm–2 and an open-circuit potential of ∼1.45 V. These results highlight the potential of π-d conjugated Co–N4 materials as an efficient catalyst for both environmental remediation and energy conversion.

Namvar, shahrirar

A comparison of wrought and powder metallurgical FeCrAl claddings under simulated LWR accident transients

Iron-chromium-aluminum (FeCrAl) alloys are potential accident tolerant fuel (ATF) cladding candidates for light-water reactors but are difficult to fabricate as thin-walled tubes via conventional cast-and-wrought routes. Powder metallurgy (PM) offers a manufacturing alternative with improved compositional control, but its transient accident performance has not been directly benchmarked against wrought variants. This study evaluates the burst behavior of commercially developed PM-processed FeCrAl alloys, PM-C26M (Fe-12Cr-6Al-2Mo) and the high precipitate density FA-SMT (Fe-22Cr-5Al-3Mo), under simulated light-water reactor accident transient conditions. Burst testing was conducted using the Severe Accident Test Station with heating rates of 5 °C/s and 50 °C/s and internal pressures ranging from 25 MPa to 100 MPa. PM-C26M reproduced wrought C26M burst behavior within 7–37 °C across the stress range, indicating that PM processing does not compromise transient strength. FA-SMT exhibited markedly higher burst temperatures and reduced heating-rate sensitivity, consistent with its engineered precipitate strengthening. FA-SMT rupture exhibited axial "unzipping" rather than the lateral tearing characteristic of PM- and wrought C26M. Post-test EBSD and fractography indicate that this behavior is strongly correlated with strain-gated intergranular void nucleation associated with the dense precipitate architecture of FA-SMT, a response absent in the comparatively clean PM-C26M matrix and consistent with rupture morphologies reported for oxide-dispersion strengthened (ODS) FeCrAl of similar base-matrix chemistry to PM-C26M. These findings highlight the potential of powder metallurgy as a viable fabrication route for ATF claddings from an accident performance standpoint.

Bell, Sam [ORNL] (ORCID:0000000251905657)

Robust and High Throughput Tools for Characterization of Wet Cellulosic Biogas Feedstocks and Co-Products: Cooperative Research and Development Final Report, CRADA Number CRD-21-21472

This project will develop standardized analytical procedures to support understanding of the chemical composition of wet manure feedstocks, and the digestate formed following anaerobic digestion of organic waste to produce renewable natural gas (RNG). The developed methods will be validated to improve component mass closure, eliminate ambiguities around key constituents, and document the precision and accuracy of the methods. Following validation of the analytical laboratory methods for characterization of wet organic waste feedstocks and digestate, NLR will use the same samples to build and validate near-infrared (NIR) models for high throughput analysis, potentially deployable at commercial facilities, enabling increased production of low carbon intensity RNG from wet organic wastes.

09 BIOMASS FUELS