Search NASA⌕ Search

SEARCH · Search NASA

Results for “Miniaturization”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 163 records · Page 9

A miniature mass spectrometer for hydrazine detection

A Miniature Mass Spectrometer (MMS) with a focal plane (Mattauch-Herzog) geometry has been developed at the Jet Propulsion Laboratory. The MMS has the potential to meet the NASA requirements of 10 parts per billion sensitivity for Hydrazine detection, as well as the requirements for instant response, portability, and low maintenance.

MMS Miniature Mass Spectrometer hydrazine detectio↗

Modeling a Miniaturized Scanning Electron Microscope Focusing Column - Lessons Learned in Electron Optics Simulation

This presentation discusses work done to assess the design of a focusing column in a miniaturized Scanning Electron Microscope (SEM) developed at the NASA Marshall Space Flight Center (MSFC) for use in-situ on the Moon-in particular for mineralogical analysis. The MSFC beam column design uses purely electrostatic fields for focusing, because of the severe constraints on mass and electrical power consumption imposed by the goals of lunar exploration and of spaceflight in general. The resolution of an SEM ultimately depends on the size of the focused spot of the scanning beam probe, for which the stated goal here is a diameter of 10 nanometers. Optical aberrations are the main challenge to this performance goal, because they blur the ideal geometrical optical image of the electron source, effectively widening the ideal spot size of the beam probe. In the present work the optical aberrations of the mini SEM focusing column were assessed using direct tracing of non-paraxial rays, as opposed to mathematical estimates of aberrations based on paraxial ray-traces. The geometrical ray-tracing employed here is completely analogous to ray-tracing as conventionally understood in the realm of photon optics, with the major difference being that in electron optics the lens is simply a smoothly varying electric field in vacuum, formed by precisely machined electrodes. Ray-tracing in this context, therefore, relies upon a model of the electrostatic field inside the focusing column to provide the mathematical description of the "lens" being traced. This work relied fundamentally on the boundary element method (BEM) for this electric field model. In carrying out this research the authors discovered that higher accuracy in the field model was essential if aberrations were to be reliably assessed using direct ray-tracing. This led to some work in testing alternative techniques for modeling the electrostatic field. Ultimately, the necessary accuracy was attained using a BEM/Fourier series hybrid approach. The presentation will give background remarks about the MSFC mini Lunar SEM concept and electron optics modeling, followed by a description of the alternate field modeling techniques that were tried, along with their incorporation into a ray-trace simulation. Next, the validation of this simulation against commercially available software will be discussed using an example lens as a test case. Then, the efficacy of aberration assessment using direct ray-tracing will be demonstrated, using this same validation case. The discussion will include practical error checks of the field solution. Finally, the ray-trace assessment of the MSFC mini Lunar SEM concept will be shown and discussed. The authors believe this presentation will be of general interest to practitioners of modeling and simulation, as well as those with a general optics background. Because electron optics and photon optics share many basic concepts (e.g., lenses, images, aberrations, etc.), the appeal of this presentation need not be restricted to just those interested in charged particle optics.

Modeling Miniaturizing Scanning↗

Application of Compressive Sensing to Gravitational Microlensing Data and Implications for Miniaturized Space Observatories

Compressive Sensing is a technique for simultaneous acquisition and compression of data that is sparse or can be made sparse in some domain. It is currently under intense development and has been profitably employed for industrial and medical applications. We here describe the use of this technique for the processing of astronomical data. We outline the procedure as applied to exoplanet gravitational microlensing and analyze measurement results and uncertainty values. We describe implications for on-spacecraft data processing for space observatories. Our findings suggest that application of these techniques may yield significant, enabling benefits especially for power and volume-limited space applications such as miniaturized or micro-constellation satellites.

Gravitational Microlensing↗

Application of Compressive Sensing to Gravitational Microlensing Data and Implications for Miniaturized Space Observatories

Compressive Sensing is a technique for simultaneous acquisition and compression of data that is sparse or can be made sparse in some domain. It is currently under intense development and has been profitably employed for industrial and medical applications. We here describe the use of this technique for the processing of astronomical data. We outline the procedure as applied to exoplanet gravitational microlensing and analyze measurement results and uncertainty values. We describe implications for on-spacecraft data processing for space observatories. Our findings suggest that application of these techniques may yield significant, enabling benefits especially for power and volume-limited space applications such as miniaturized or micro-constellation satellites.

Compressive Sensing↗

Integrated Utility Module for Future NASA Miniature Spacecraft

NASA initiated a program for space-validation of selected technologies relating to miniature spacecraft and microinstruments. Addressed is the proposed development of the Integrated Utility Module (IUM) which integrates structural integrity, thermal management, power distribution, data & signal transmission, radiation & meteoroid protection, etc. into a lightweight, compact, cableless package.

NASA↗

NASA Ultra-Sensitive Miniature Accelerometer

Using micro-machined silicon technology, an ultra-sensitive miniature accelerometer can be constructed which meets the requirements for microgravity experiments in the space environment. Such an accelerometer will have a full scale sensitivity of 10 -2 g, a resolution of 10 -8 g, low cross-axis sensitivity, and low temperature sensitivity. Mass of the device is approximately five grams and its footprint is 2 cm x 2 cm.

miniature↗

Radiation-hard miniature optical engine with high bandwidth

Future silicon trackers will be operated in an intense radiation environment and require large volumes of data to be transmitted off detector. In addition, the optical modules must be of low mass in order to limit multiple scattering and nuclear interactions that would degrade the overall performance of the detector. Here, we present a miniature optical engine that satisfies these constraints. The optical engine consists of an ASIC driving a VCSEL (Vertical Cavity Surface Emitting Laser) array in an optical package. Two ASICs are designed to operate a 12-channel VCSEL array at 1.28 or 5.12 Gb/s per channel, which yields a total data rate of up to 60 Gb/s. The core transistors are fabricated in a 65 nm CMOS process which enhance the radiation-hardness. Each channel contains equalizer (CTLE) and clock-data recovery circuits (CDR) so that the ASIC can restore the highly distorted electrical signal after propagating through several meters of cables of small diameter. The equalizer, CDR, and VCSEL driver are configured via a digital I 2 C chip interface with triple redundant memory to mitigate single event upset (SEU) effects. The bias and modulation currents are controlled by a digital-to-analog converter (DAC). We present the design of the circuit together with the results of the simulations and preliminary measurements.

47 OTHER INSTRUMENTATION↗

Miniature fluorescence sensor for quantitative detection of brain tumour

Fluorescence-guided surgery has emerged as a vital tool for tumour resection procedures. As well as intraoperative tumour visualisation, 5-ALA-induced PpIX provides an avenue for quantitative tumour identification based on ratiometric fluorescence measurement. To this end, fluorescence imaging and fibre-based probes have enabled more precise demarcation between the cancerous and healthy tissues. These sensing approaches, which rely on collecting the fluorescence light from the tumour resection site and its “remote” spectral sensing, introduce challenges associated with optical losses. In this work, we demonstrate the viability of tumour detection at the resection site using a miniature fluorescence measurement system. Unlike the current bulky systems, which necessitate remote measurement, we have adopted a millimetre-sized spectral sensor chip for quantitative fluorescence measurements. A reliable measurement at the resection site requires a stable optical window between the tissue and the optoelectronic system. This is achieved using an antifouling diamond window, which provides stable optical transparency. The system achieved a sensitivity of 92.3% and specificity of 98.3% in detecting a surrogate tumour at a resolution of 1 × 1 mm 2 . In conclusion, as well as addressing losses associated with collecting and coupling fluorescence light in the current ‘remote’ sensing approaches, the small size of the system introduced in this work paves the way for its direct integration with the tumour resection tools with the aim of more accurate interoperative tumour identification.

59 BASIC BIOLOGICAL SCIENCES↗

The integrated miniaturized electrostatic analyzer: A space plasma environment sensor

The integrated Miniaturized Electrostatic Analyzer (iMESA) was a satellite-based ionospheric sensor that operated on NASA’s Space Test Program Satellite (STPSat-3) from December 2013 to July 2019. The instrument’s scientific objective was to (1) measure the plasma density in low Earth orbit, (2) measure the plasma temperature in low Earth orbit, and (3) quantify the spacecraft potential with respect to the ambient plasma potential in the ionosphere. iMESA sampled the ionosphere every 10 s by measuring the ion current density through the ESA as a result of the motion of the spacecraft through the plasma. Current density spectra were transmitted to the ground where they were post-processed into ion density spectra and then analyzed numerically to determine the ion density, ion temperature, and spacecraft potential. This article discusses the instrument design and simulation, the determination of a geometric factor, and data processing procedures and evaluates the final data product with regard to the mission success criteria. Here, the ion density and ion temperature captured by the iMESA instrument are on the same order and range as the values predicted in the literature. The spacecraft potential was also quantified. The conclusion after the evaluation of the instrument’s data product is that the scientific mission is successful on all three points.

47 OTHER INSTRUMENTATION↗

Probe measurements of electric field and electron density fluctuations at megahertz frequencies using in-shaft miniature circuits

In this work, a four-tip electrostatic probe is constructed to measure high-frequency (0.1–10 MHz) fluctuations in both the electric field (one component) and electron density in a laboratory plasma. This probe also provides data for the local electron temperature and density. Circuits for high-frequency measurements are fabricated on two miniature boards, which are embedded in the probe shaft, near the tips to minimize the pickup of common-mode signals. The amplitude and phase response of two circuits to sinusoidal test signals are measured and compared with results from modeling. For both circuits, the phase shift between input and output signals is relatively small (<30°). The performance of the probe is verified in a high-density (~10 13 cm –3 ) and low-temperature (≲10 eV) plasma. The probe successfully measures high-frequency (~2 MHz) fluctuations in the electric field and density, which are associated with lower hybrid drift waves. This probe can provide information on the wave-associated anomalous drag, which can be compared with the classical resistivity.

47 OTHER INSTRUMENTATION↗

Managing photon flux in a miniaturized photoionization detector

Miniaturized photoionization detectors (PIDs) are used in conjunction with gas chromatography systems to detect volatile compounds in gases by collecting the current from the photoionized gas analytes. PIDs should be inexpensive and compatible with a wide range of analyte species. One such PID is based on the formation of a He plasma in a dielectric barrier discharge (DBD), which generates vacuum UV (VUV) photons from excited states of He to photoionize gas analytes. There are several design parameters that can be leveraged to increase the ionizing photon flux to gas analytes to increase the sensitivity of the PID. To that end, the methods to maximize the photon flux from a pulsed He plasma in a DBD-PID were investigated using a two-dimensional plasma hydrodynamics model. The ionizing photon flux originated from the resonance states of helium, He(3P) and He(2 1 P), and from the dimer excimer He 2 *. While the photon flux from the resonant states was modulated over the voltage pulse, the photon flux from He 2 * persisted long after the voltage pulse passed. Several geometrical optimizations were investigated, such as using an array of pointed electrodes. However, increasing the capacitance of the dielectric enclosing the plasma chamber had the largest effect on increasing the VUV photon fluence to gas analytes.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

A Novel Miniaturized MIMO Microstrip Patch Antenna Array with EBG- and Slot-Loading

A compact four-element multiple-input multiple-output (MIMO) antenna array based on the miniaturized mi-crostrip patch is presented. The reduction in array form factor is realized by partially populating the ground plane with elec-tromagnetic band gap (EBG) cells constructed from cross slots, in combination with reactively loading each patch with a slot. The resultant 2 × 2 array system demonstrates excellent inter-element isolation and can be easily fabricated using traditional milling and printing techniques, as it exploits a 2D layout that can be conveniently implemented on two sides of a single-layer substrate, without the need for any via structures. The operation of the array near the 2.5 GHz band is verified with full-wave simulations. The size of the new design is approximately 42% of that employing conventional patch elements.

Liao, DaHan↗

A New Miniaturized Acoustic Transmitter for Marine Animal Tracking

Most marine renewable energy (MRE) technologies are still in their infancy. Many uncertainties remain regarding MRE systems’ impacts on the marine environment and species where they are deployed, which is one of the major hurdles for these systems to be widely adopted at a commercial scale. Currently, the primary technologies to monitor marine animals’ behavior around existing or potential MRE deployment sites are optical and acoustic imaging. However, these methods cannot identify individual animals and thus are less useful in identifying protected species and studying their behavior. Implantable acoustic transmitters with unique identification codes could serve as a complementary technology. To minimize potential bias introduced to the study results, the implanted transmitters must be sufficiently small and light to not affect the animals’ behavior while still having acceptable signal strengths and service life. Recently, we developed a new miniaturized acoustic transmitter that offers a significantly improved signal strength and service life (140 days [projected value] at a 5-s transmission interval) in a smaller and lighter package (0.45 g in the air), compared to the existing technologies. The detection range and detection efficiency of the new transmitter were tested in an actual marine environment and demonstrated a detection range of up to 330 m, a 65% improvement over the existing commercial counterparts operating at similar frequencies. Here, we report the design principles, performance, and manufacturing procedure of the transmitter. Finally, theoretical estimates of the detection range, the actual range, and detection efficiency results from the field testing are presented.

acoustic telemetry↗

Miniaturized Magnetoelastic Sensor System

This article describes the design, assembly, and implementation of a hand-held, magnetic-field-based sensor system that can be adapted for a variety of sensing applications. The miniaturized system is based on Chemical Identification by Magneto-Elastic Sensing (ChIMES) technology, which uses three concentric solenoid coils to wirelessly interrogate a sensor body comprised of a response material coupled to a magnetoelastic wire. The response material expands when it encounters a target, imposing mechanical stress on the wire and altering its magnetic permeability. The sensor bodies are passive, requiring no external power source, and they are small, measuring about 15 mm in length and 3.0 mm in diameter. Up to four sensor bodies can be configured as an evenly-spaced linear array. The sensor system operates by applying a low-frequency, current-stabilized, filtered triangle wave to a uniform-density excitation coil to switch the magnetic domains within the wire. Further, the responses from the sensors are picked up by a detection coil as stress-induced changes in the Faraday voltage, and the strong magnetic field induced by the excitation coil in the detection coil is nullified by a cancellation coil reverse-wound in series with the detection coil. The responses of the sensors in an array are separated in time by a linear gradient dc biasing coil. The sensors can be interrogated through metallic and nonmetallic barriers. The signals from the detection coil and the excitation coil are digitized by a pair of bipolar analog-to-digital converters (ADCs). A Raspberry Pi single-board computer (SBC) and associated software perform data acquisition and control all aspects of the sensor system hardware. The program allows the user to select the number of sensors in the array, the type of signal that is being collected, and the number of samples to take. The program also allows for signal processing of the sensor data, such as baseline correction. The program can differentiate sensor peaks from each other and calculate the magnitude of each sensor response with less than 1% error. The data are then displayed along with a graph of the signal.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗