Search NASA⌕ Search

SEARCH · Search NASA

Results for “PCM energy storage”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 163 records · Page 9

Identifying Molecular Scale Interactions of Nucleating Agents with Salt Hydrates for Thermal Energy Storage Applications

Latent heat based thermal energy storage is of interest as a method to mitigate and time-shift thermal load peaks and hence reduce energy demands for heating and cooling buildings. Notably, Glauber’s salt (GS) presents a good choice as a phase change material (PCM) for building applications because it has a melting point near room temperature (i.e., 32.4 °C), a large heat of fusion and energy density, and is low cost (~ $100/ton). However, there are several known limitations to using GS as a PCM, such as incongruent melting, high degree of supercooling, and formation of other hydration states, which renders GS unsuitable for practical use. Inorganic crystals acting as nucleating agents can avoid some of these issues with GS [1]. Understanding nucleation behavior through typical calorimetry experiments offers limited insight into the molecular-scale mechanisms. Here, we report isothermal titration calorimetry [2] to investigate the interactions between sodium sulfate salt and an organic nucleating agent - glycine. Our experiments provide qualitative and quantitative understanding of how glycine interacts with sodium sulfate across various temperatures. The findings offer insights into the nucleation onset temperature (24°C) and underscore the pivotal role of glycine's zwitterionic structure in facilitating nucleation. This preliminary work provides a foundation for subsequent exploration of nucleating agents that would be incorporated in different salt hydrate systems. 1. Purohit, B. K., and V. S. Sistla. "Inorganic salt hydrate for thermal energy storage application: A review." Energy Storage 3, no. 2 (2021): e212. 2. Velázquez-Campoy, Adrián, Hiroyasu Ohtaka, Azin Nezami, Salman Muzammil, and Ernesto Freire. "Isothermal titration calorimetry." Current protocols in cell biology 23, no. 1 (2004): 17-8.

calorimetry, nucleation & growth↗

Feasibility Analysis for the Use of Retrofitted Air-Conditioners Using Thermal Energy Storage (TES) for High Ambient Temperature (HAT) Countries

In high ambient temperature (HAT) countries, summer temperatures exceed 35℃, degrading the performance of air-conditioning systems and straining power grids. In this paper, a feasibility analysis was conducted to investigate potential savings during the peak using latent Thermal Energy Storage (TES) at near room phase-change temperatures, replacing condensers, thus, minimizing temperature lifts. Weather data, building loads, and baseline air-conditioning systems data were gathered for Dubai. A transient vapor-compression model in Modelica was used to compare the COP, total power input and cooling capacity of the air-conditioner at peak hours when ambient temperatures range between 35 – 45 ⁰C versus the TES-Phase-Change Material (PCM) melting temperatures from 22 – 28⁰C. The results indicate that the TES-PCM can enhance the system COP at the peak by a factor 1.4 and 2 for during for outdoor temperatures of 35 – 40⁰C, and 40 – 45⁰C, respectively. Lower melting temperature PCMs were able to reduce the required power input by 30-50%, with more savings occurring at higher temperature days. On the other hand, higher temperature PCMs enhancements were minimal especially at outdoor ambient temperatures ranging between 35 – 40⁰C. Improvements to the cooling capacity range from 8 – 18 % for the outdoor temperature range of 35 – 45 ⁰C. An economic analysis was conducted to find the potential saving in utility costs for 30%, 60%, and 90% of the space cooling demands of Dubai, and find the trade-off points between utility savings and cost of PCM-TES implementation. If the peak loads are to be shifted by 6 hours daily, the percentage utility savings for the city is 18%. Using estimated costs of the PCM-TES, ranging from $200-500/kWh, the daily load shifting hours were estimated to range from 4 hours at the lowest cost systems to 2.5 hours at the highest costs.

25 ENERGY STORAGE↗

Guidelines for Phase Change Material Selection Based on a Holistic System Model

Concentrating solar power (CSP) has potential to increase the amount of renewable energy on electric grids and reduce global carbon emissions, in particular because of its capability to incorporate inexpensive thermal energy storage. To realize this potential, development of latent heat storage with phase change materials (PCMs) is attractive because of its high energy density and low material cost. Research in this area has identified many promising materials, and has developed effective storage system designs that could be used to deploy PCMs. However, the field has lacked a rigorous methodology to select the optimal material for a particular CSP system. To address this need, here we present a holistic model that evaluates all important influences of PCM properties on the performance and cost of an entire CSP plant. We apply this model to over 100 of the most widely considered candidate materials, including both salts and metals. We quantify the relative value of each PCM property, and identify leading materials for application in CSP systems. This method and our results may aid future efforts to develop latent heat storage by providing a more informed view of how material selection impacts an entire CSP system.

14 SOLAR ENERGY↗

A buffering heat exchanger/thermal energy storage system for desalination applications

A buffering heat exchanger/thermal energy storage (BHXTES) system was designed using a fast-response phase-change material/graphite foam (PCM/GF) medium for desalination and potentially other industrial applications. Unlike a store-now-and-use-later TES system, this study focused on developing a dynamically balanced, continuously used, system that optimized three functions. A lab-scale prototype was designed and fabricated with a PureTemp 151/GF storage medium. The experimental data showed excellent thermal performance repeatability indicating minimal effects of PCM expansion and contraction on the GF as well as negligible PCM redistribution effects. The experimental data also served as a validation of the numerical model of the BHXTES system, after which optimization of the BHXTES system was conducted through numerical simulations for both PureTemp 151/GF and solar salt/GF as the storage medium. The results show that, with a Therminol 55 heat transfer fluid, continuous operation of the system can be realized with a solar energy source through cycles of 8-h changing for desalination and energy storage with the supplied heat followed by 16-h discharging for desalination with the stored energy. As a result, the working fluid outlet temperatures are generally in the ranges of approximately 128–160 °C for a PureTemp 151/GF medium and 198–220 °C for a solar salt/GF medium.

Buffering↗

Novel Functional Thermal Energy Storage Materials for Buildings Applications

The leakage of solid-liquid phase change materials (PCMs) tremendously limits their long-term application in thermal energy storage (TES). In this work, we present durable and form-stable shape-stabilized PCMs (ss-PCMs) for TES in building envelopes. These ss-PCMs are fabricated by encapsulating polyethylene glycol (PEG) consisting of different molecular weights within mesoporous magnesium oxide and silica dioxide. For the first time, the phase transition temperature (Tt) of ss-PCMs has been fine-tuned synthetically to be comfortable to building occupants by utilizing PEG blends with molecular weights of 600 and 800 g/mol. Several parameters, including surface hydrophilicity/hydrophobicity, surface area, and PCM loading percentage, have been studied to maximize the latent heat enthalpy for high energy efficiency and maintain form stability. The best ss-PCM candidate with suitable Tt and appreciable latent heat enthalpy exhibits a repeatable phase change behavior for up to 1,000 thermal cycles without leakage, which provides a promising solution for durable TES in buildings. The Tt tunability extends its application over a wider temperature range beyond buildings.

building envelope↗

Pushing the Envelope-Moving Dynamic Building Envelope Thermal Energy Storage Systems Mainstream: Preprint

Buildings contribute to nearly 40% of the U.S. national energy consumption and a significant portion of CO2 emissions. More importantly, disadvantaged communities are disproportionately affected by energy burden and thermal discomfort in their homes. This paper will discuss two novel DOE's BTO supported thermal energy storage (TES) integrated dynamic building envelope technologies, their ability to harvest ambient energy, and improve energy efficiency by reducing HVAC loads and peak electricity demand while enhancing energy and thermal resilience in buildings. The paper will also discuss the recent advancements that have made these systems more affordable and easier to integrate into new and existing buildings. The first solution is a thermally anisotropic building envelope (TABE) system that can redirect ambient thermal energy (heat or coolness) from diurnal outdoor conditions, solar irradiance, and night sky radiation from the envelope to a hydronic loop. The redirected thermal energy can be stored in a TABE-integrated thermal energy storage system and use the stored energy to offset HVAC energy use and peak demand. The second solution is an innovative plug-and-play thermal switch in the form of insertable plugs integrated with a phase change material (PCM). The plug can vary its thermal resistance based on the indoor and outdoor conditions, thus allowing preferential directional heat flow, and enhancing utilization of free ambient cooling and heating to charge/discharge the PCM, much like a solid-state economizer. While the fist solution can be actively controlled, the second solution is passive, requiring no external power, and work solely based on the ambient temperature.

anisotropic envelope↗

Pushing the Envelope—Moving Dynamic Building Envelope Thermal Energy Storage Systems Mainstream

Buildings contribute to nearly 40% of the U.S. national energy consumption and a significant portion of CO2 emissions. More importantly, disadvantaged communities are disproportionately affected by energy burden and thermal discomfort in their homes. This paper will discuss two novel DOE's BTO supported thermal energy storage (TES) integrated dynamic building envelope technologies, their ability to harvest ambient energy, and improve energy efficiency by reducing HVAC loads and peak electricity demand while enhancing energy and thermal resilience in buildings. The paper will also discuss the recent advancements that have made these systems more affordable and easier to integrate into new and existing buildings. The first solution is a thermally anisotropic building envelope (TABE) system that can redirect ambient thermal energy (heat or coolness) from diurnal outdoor conditions, solar irradiance, and night sky radiation from the envelope to a hydronic loop. The redirected thermal energy can be stored in a TABE-integrated thermal energy storage system and use the stored energy to offset HVAC energy use and peak demand. The second solution is an innovative plug-and-play thermal switch in the form of insertable plugs integrated with a phase change material (PCM). The plug can vary its thermal resistance based on the indoor and outdoor conditions, thus allowing preferential directional heat flow, and enhancing utilization of free ambient cooling and heating to charge/discharge the PCM, much like a solid-state economizer. While the fist solution can be actively controlled, the second solution is passive, requiring no external power, and work solely based on the ambient temperature.

Shrestha, Som↗

Thermal Image Processing for Feature Extraction from Encapsulated Phase Change Materials

Encapsulated inorganic particles with high melting points (>300 °C) are desired as high-temperature Phase Change Materials (PCMs) for next-generation Latent Heat Thermal Energy Storage (LHTES) systems. One of the many challenges during the development of PCMs is to achieve a high throughput that in turn depends on accurately modeling the relation between process parameters and geometric & thermal properties of the PCMs particle. During the production of the PCMs, a high-speed infrared camera is used to acquire images of the encapsulated material under controlled illumination conditions. This research article focuses on the development of image processing techniques for both geometric and thermal feature extraction during the development of the PCMs. A user-friendly GUI has been designed in MATLAB and preliminary experimental results have demonstrated that the method is fast, accurate and reliable for a high throughput production. The extracted features will be used to develop Machine Learning (ML) models to predict the geometric and thermal properties of the PCM based on the process parameter settings. The ML model will accelerate the search for the optimized process settings to boost the throughput of the production.

25 ENERGY STORAGE↗

Enhancing building energy performance by effectively using phase change material and dynamic insulation in walls

Deploying phase change materials (PCMs) in building envelopes can be efficacious in reducing space heating/cooling loads and providing load shedding and shifting capacity. However, the full potential of PCM-integrated envelopes can only be harnessed if the PCM undergoes phase change using free ambient heating/cooling, and the stored energy is effectively transferred between the exterior and the interior environments. Traditional thermal insulation (with a fixed thermal resistance) limits PCM utilization, which restrains the energy saving potential of a PCM-integrated envelope to a small percentage. Proposed dynamic insulation material and system (DIMS) provides the option of varying its thermal resistance based on the indoor and outdoor conditions. Although it has been established that employing PCM as well as DIMS in building envelopes separately improves buildings’ energy performance, no prior studies that analyzed the combined influence of both technologies were identified. In this study, we examine a novel wall design, comprising a layer of PCM between two layers of DIMS. We note that the PCM-DIMS-integrated wall provides significantly higher energy saving potential than the DIMS-only integrated wall or the PCM-only integrated wall in all the climates and wall orientations analyzed in this study. Depending on the climate, the PCM-DIMS-integrated wall could provide 15–72% reduction in annual heat gain and 7–38% reduction in annual heat loss. The analysis presented in this study supports the need to develop scalable dynamic insulations combined with thermal energy storage systems for buildings.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Evaluation of Phase Change Plaster/Paste Composites for Building Envelopes

Thermal energy storage (TES) materials increase a building’s thermal mass and provide the flexibility to shave and time-shift energy use. These materials are needed to enable grid-interactive efficient buildings, allowing building occupants to lower costs by leveraging free ambient heating/cooling as well as shifting consumption to cheaper electricity periods. Phase change materials (PCMs) that store heat through a solid-liquid/solid-solid transformation are of particular interest for TES because of their ability to store large amounts of energy across a constant temperature or very small temperature range. Furthermore, previous studies on PCM building envelopes evaluated products that may only be incorporated as part of new construction and are not easily applicable to existing, energy-intensive buildings. In this work, we leverage laboratory PCM characterization and whole-building energy simulation to study the energy and cost savings of PCM plaster/paste coatings, which can be applied post construction to both new builds and retrofits of existing buildings (about 40% of residential buildings in the United States fall into the retrofit category). We evaluated the energy impact of PCM plaster/paste composites for a single-family residential building in the United States, including layer design (location and thickness), composite properties (phase change temperature, energy density, and shape of the enthalpy curve), and U.S. climate zone. The enthalpy curve shape of PCM shows that phase change temperature and energy density are not the only two parameters that must be considered for PCM selection. Maximizing the energy density amid the effective TES zone is key to boosting energy savings. We also studied PCM price targets with the aim of achieving reasonable payback periods based on both block and time-of-use electricity rates. Moreover, we developed an empirical equation to provide a rough estimate of the energy savings potential of incorporating PCM without the need to perform detailed simulations. These results will help guide the selection and design of PCM plaster/paste composite elements for residential building envelopes.

ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATION↗

Micro-Environmental Control System (Final Report)

This project developed an innovative micro-environmental control system (µX) that enables office buildings to reduce energy used for heating and cooling by 15% or more. The µX is a compact, quiet, and ergonomic device that is designed to be installed under an office workstation; it is designed to maintain occupant comfort when room thermostat setpoints are incremented by 4°F or more (warmer in the summer and cooler in the winter) to save energy. When ambient room temperatures are outside of the usual comfort range, the µX maintains occupant comfort by delivering personalized cooling or heating locally to each office worker. The µX provides personalized cooling using a micro vapor compression system that includes a new high-performance micro-scroll compressor and a novel thermal storage unit. The vapor compression system operates at night to freeze a phase-change material (PCM). During the workday, the cooling stored in the PCM is released as a cool breeze of air to make occupants more comfortable. The micro-scroll compressor was developed specifically for this application; it is smaller than any of its type, minimizing the amount of power needed. In heating mode, the µX maintains occupant comfort using a foot heating mat with an infrared reflective box. The µX R&D project was conducted by Syracuse University in collaboration with United Technologies Research Center, Air Innovations, Bush Technical, and Cornell University. Over the course of the initial three-year project, the team developed and evaluated four versions of the unit, advancing the concept to Technology Readiness Level 6. The capabilities of individual proof-of-concept prototypes were verified in tests that were conducted with: 1) units in psychrometric chambers, 2) an instrumented manikin in a laboratory, and 3) human subjects in laboratories that simulate office environments. The tests verified that the µX prototypes met or exceeded all performance targets required to enable office buildings to reduce energy used for heating and cooling by 15% or more by maintaining occupant comfort when thermostat setpoints are incremented by 4°F or more.

25 ENERGY STORAGE↗

Radiative Cooling Paints: Application on Warehouses and Integration with Phase Change Materials

Despite extensive research on radiative cooling (RC), researchers are still working to understand its best implementation strategy and potential benefits. Understanding this could be an instrumental part of reducing building energy costs and combating climate change. In this work, we introduce two concepts to achieve this goal and broaden the application of RC paints. While building energy simulations for RC are common, most studies focus on single-layer paints in residential settings. Limited research exists on warehouses, and no literature has conducted multi-climate zone analyses or included RC technologies with >90% reflectance. As RC technology advances in efficiency, versatility, and affordability, large-scale simulations across diverse climates are crucial, particularly for warehouses as a passive indoor temperature control solution. Here, a TRNSYS-modeled single-story warehouse assesses the energy impact of BaSO4-based RC paints. Another under-explored RC application is its integration with phase change materials (PCMs), which provide thermal regulation via latent heat storage. Though RC and PCMs have been combined by placing PCMs atop, beneath, or within RC layers, studies focus on either experiments or modeling, with no validation between the two. Here, we develop a simple RC+PCM experimental and modeling setup, placing RC paint atop an aluminum cell filled with a Rubitherm PCM.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Nature-inspired lotus-shaped fins combined with hybrid nanoparticles and metal foam for high-performance latent heat thermal energy storage

Latent heat thermal energy storage (LHTES) systems play a critical role in renewable energy integration by providing high energy density and nearly isothermal operation during phase transitions. However, their performance is often limited by slow melting/charging rates, which motivates the search for enhanced heat transfer designs. This study investigates the melting behavior of RT-82 phase change material (PCM) using novel lotus-shaped fins combined with copper metal foam and conductive graphene nanoparticles and carbon nanotubes. A two-dimensional enthalpy-porosity model in ANSYS Fluent was developed to simulate the charging/melting process, capturing non-thermal equilibrium between the foam and PCM/nano-PCM. In this study, effects of fin geometry, nanoparticle concentration, and foam porosity on melting dynamics and cost-performance trade-offs were investigated. Results showed that natural convection accelerated melting by ~12% compared to conduction-only scenarios. Optimized lotus-shaped fins with higher fin density (T3F4 and T3F10) achieved up to 63% faster melting relative to sparse configurations. Graphene nanoparticles improved thermal conductivity, with a 6% volume fraction, by reducing melting time by ~6.9%, while their combination with 75% porosity foam achieved a maximum reduction in the melting time of ~51% compared to pure PCM. Cost-performance analysis identified T3F4 as the most balanced design, offering rapid thermal response without excessive material costs, while moderate-density designs like T3S6 provided economical alternatives with acceptable performance. These results highlight the performance enhancement that can be achieved by integrating bio-inspired fins, nanoparticles, and foams, into compact and efficient LHTES for solar heating, building thermal management, and industrial waste-heat recovery applications.

25 ENERGY STORAGE↗

Thermal management of a high temperature sodium sulphur battery stack

The sodium sulfur battery is an advanced secondary battery with high potential for grid-level storage due to their high energy density, low cost of the reactants, and high open-circuit voltage. However, as the operating temperature of the battery is high (about 300 °C), effective thermal management is required to prevent thermal runaway under high current density operation. Here, to develop efficient thermal management strategies, a detailed, thermo-electrochemical, non-isothermal, distributed dynamic model of a sodium-sulfur battery stack is developed. Models of three thermal management strategies are developed and analyzed in this work: active cooling, passive cooling, and hybrid cooling. The active cooling strategy uses air as the cooling medium whereas, the passive cooling strategy uses a phase change material. In the hybrid cooling strategy, both active and passive cooling strategies are used. Due to the high operating temperature of the sodium sulfur batteries, the rejected heat can be utilized effectively and consequently a high variability in the heat rejection rate may not be acceptable. Performance of these strategies is analyzed under high current density operation by evaluating the variability in the cell temperature during charge/discharge cycles, temperature difference between the cells based on their locations, and variability in the heat rejection rate. The phase change-based hybrid thermal management strategy with an embedded controller maintained the temperature variation within ±/- 2.8 °C. Considering the tradeoff between the capital cost for PCM, fan power requirement, and variability in the heat rejection rate, the optimal quantity of the PCM and the maximum air velocity for the maximum current density of 260 mA/cm 2 (0.55 C-rate) were found be 0.74 g/Wh and 3 m/s, respectively.

25 ENERGY STORAGE↗

Experimental and numerical study on the impacts of various long carbon fiber inserts on the thermal performance of phase change materials

In thermal energy storage systems, phase change materials (PCMs) are widely used to provide efficient storing and extraction of thermal energy. However, most PCMs have low thermal conductivities, which limit the heat transfer of the latent energy inward/outward. In this study, the impacts of various fiber inserts on the solidification and melting processes with PCM were investigated by experiments and simulations. It was found that long anisotropic carbon fibers with high thermal conductivities can not only increase the heat transfer within PCM by enlarging hot-cold interface areas, but also act as crystallization nuclei and increase the solidification of PCM during the charging process. Recalescence of PCM during solidification was observed. COMSOL models were used to understand the thermal transfer mechanisms. COMSOL Multiphysics models of a single carbon fiber filament in PCM showed that the anisotropy in thermal conductivities controlled the radial and axial heat transfer ratios along its fiber axis and can enhance both the solidification and melting processes.

Zhou, Xinzhang↗

Parametric study of solid-solid translucent phase change materials in building windows

Thermal energy storage and solar radiation management are crucial to improve the sustainability and energy efficiency of buildings. Compared with the implementation of phase change materials (PCMs) in opaque components, the energy saving potential of incorporating PCMs in transparent glazing windows is much less studied and not well understood. Here we present a comprehensive parametric study of novel PCM windows for building energy saving with a focus on optimizing and quantitatively distinguishing the contributions from the optical and thermal properties of the PCM, which is particularly useful for the design of solid-solid PCM windows. We investigate a reference commercial office building using EnergyPlus by developing an equivalent model of our PCM window that is compatible with EnergyPlus's modeling capabilities. Compared with a clear-clear double-pane window, the integration of 3 mm solid-solid PCMs with optimal properties in warm, mixed, and cold climates can respectively save up to 17.2%, 14.0%, and 5.8% energy for the HVAC (heating, ventilation, and air conditioning) system, and 9.4%, 6.7%, and 3.2% energy for the whole building. We also demonstrate that these energy savings are most sensitive to the solar absorptance of PCMs for all three climates. The optimal transition temperature varies with climate and is related to the climate and solar radiation heat gain. Other issues are also briefly discussed, such as hysteresis, window orientations, and the effect of interior lighting. Finally, although the optimal PCM windows show energy saving performance comparable with low-emissivity windows, the PCM windows provide a unique advantage in terms of shifting HVAC loads which can provide benefits to the electrical grid.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Preliminary Design of Critical Experiments Involving Commercially Available B 4 C Neutron Absorber Plates with Low-Enriched UO 2 Fuel

The International Criticality Safety Benchmark Evaluation Project (ICSBEP) is an initiative to provide high-quality benchmark data in a standardized format for criticality safety analysts to use to validate calculational tools and nuclear data. In the last released 2022 version, the ICSBEP handbook contains over 5,000 critical experiment descriptions, results, and associated models. This paper describes the critical configurations proposed and calculations performed as part of the conceptual design phase of Integral Experiment Request (IER) 554 (IER-554). The goal of IER-554 is to add to the benchmark experiments available to the criticality safety community by designing critical experiments that can analyze how adding commercially available Boralcan plates to an assembly of low-enriched UO2 fuel rods affects the effective neutron multiplication factor (k eff ). Boralcan, a neutron absorber product developed by Rio Tinto, is made of B4C in an Al 1100 matrix and is commonly used for criticality suppression in fuel storage pools. In the current version of the ICSBEP handbook, only a few dated critical experiments involve B4C materials, and none involve Boralcan in a thin plate shape. The experiments designed as part of IER-554 are intended to be performed at the Sandia Pulsed Reactor Facility/Critical Experiments (SPRF/CX) apparatus at Sandia National Laboratories. SPRF/CX is a well-characterized assembly considered trustworthy by the benchmarking community because of the numerous high-quality evaluations with very low experimental uncertainties included in the ICSBEP handbook. Figure 1 illustrates the assembly for a particular configuration from LCT-078, one of the published benchmarks in the ICSBEP handbook. The experiments will be moderated and reflected by light water at ambient atmospheric pressure. Before the plates are inserted in the critical assembly, they will be characterized with x-ray computed tomography (XCT) to identify the sizes and distribution of the B 4 C powder particles inside the plates. The preliminary design calculations were performed with SCALE 6.3.0 using the KENO V.a sequence for the criticality calculations, the CE-TSUNAMI-3D sequence for the sensitivity and uncertainty studies, and the ENDF/B-VII.1 Continuous Energy cross section library. All the calculation results presented have 10 pcm statistical uncertainties. A set of critical experiments with Boralcan plates could increase the confidence of the criticality safety community in its modeling methods when using this type of neutron absorber material. Experiments would also help validate k eff calculations, and the industry could use these validations to change the B loading credit limits from the US Nuclear Regulatory Commission standard review plan for dry cask storage of spent nuclear fuel. This paper summarizes only part of the analysis documented in the preliminary design report.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

Chemically Stable Polyarylether-Based Metallophthalocyanine Frameworks with High Carrier Mobilities for Capacitive Energy Storage

Covalent organic frameworks (COFs) with efficient charge transport and exceptional chemical stability are emerging as an import class of semiconducting materials for opto-/electronic devices and energy-related applications. However, the limited synthetic chemistry to access such materials and the lack of mechanistic understanding of carrier mobility greatly hinder their practical applications. Herein, we report the synthesis of three chemically stable polyarylether-based metallophthalocyanine COFs (PAE-PcM, M = Cu, Ni, and Co) and facile in situ growth of their thin films on various substrates (i.e., SiO 2 /Si, ITO, quartz) under solvothermal conditions. We show that PAE-PcM COFs thin films with van der Waals layered structures exhibit p -type semiconducting properties with the intrinsic mobility up to ~19.4 cm 2 V -1 s -1 and 4 orders of magnitude of increase in conductivity for PAE-PcCu film (0.2 S m -1 ) after iodine doping. Density functional theory calculations reveal that the carrier transport in the framework is anisotropic, with the out-of-plane hole transport along columnar stacked phthalocyanine more favorable. Furthermore, PAE-PcCo shows the redox behavior maximumly contributes ~88.5% of its capacitance performance, giving rise to a high surface area normalized capacitance of ~19 μF cm -2 . Overall, this work not only offers fundamental understandings of electronic properties of polyarylether-based 2D COFs but also paves the way for their energy-related applications.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗