Search NASA⌕ Search

SEARCH · Search NASA

Results for “Performance, Reliability, Design, Measurement”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 163 records · Page 9

Reliability of the Danish Aerospace Corporation Portable Pulmonary Function System

Metabolic gas analysis is a critical component of investigations that measure cardio-pulmonary exercise responses during and after long-duration spaceflight. The primary purpose of the current study was to determine the reliability and intra-subject repeatability of a metabolic gas analysis device, the Portable Pulmonary Function System (PPFS), designed for use on the International Space Station (ISS). The second objective of this study was to directly compare PPFS measurements of expired oxygen and carbon dioxide (FEO2 and FECO2) to values obtained from a well-validated clinical metabolic gas analysis system (ParvoMedics TrueOne (c) [PM]). Eight subjects performed four peak cycle tests to maximal exertion. The first test was used to prescribe work rates for the subsequent test sessions. Metabolic gas analysis for this test was performed by the PM, but samples of FEO2 and FECO2 also were simultaneously collected for analysis by the PPFS. Subjects then performed three additional peak cycle tests, consisting of three 5-min stages designed to elicit 25%, 50%, and 75% maximal oxygen consumption (VO2max) followed by stepwise increases of 25 W/min until subjects reached volitional exhaustion. Metabolic gas analysis was performed using the PPFS for these tests. Intraclass correlation coefficients (ICC), within-subject standard deviations (WS SD), and coefficients of variation (CV%) were calculated for the repeated exercise tests. Mixed model regression analysis was used to compare paired FEO2 and FECO2 values obtained from the PPFS and the PM during the initial test. The ICC values for oxygen consumption (VO2), carbon dioxide production (VCO2), and ventilation (VE) indicate that the PPFS is highly reliable (0.79 to 0.99) for all exercise levels tested; however, ICCs for respiratory exchange ratio (RER) were low ( 0.11 - 0.51), indicating poor agreement between trials during submaximal and maximal exercise. Overall, CVs ranged from 1.6% to 6.7% for all measurements, a finding consistent with reported values that were obtained using other metabolic gas analysis techniques. The PPFS and PM produced comparable FEO2 data; however, there was less agreement between measures of FECO2 obtained from the two devices, particularly at lower CO2 concentrations. The PPFS appears, in practically all respects, to yield highly reliable metabolic gas analysis data. Lower reliability of RER measurements reported in the literature and likely is not a function of the PPFS device. Further examination of PPFS CO2 data is warranted to better understand the limitations of these PPFS measurements. Overall, the PPFS when used for repeated measures of cardio-pulmonary exercise should provide accurate and reliable data for studies of human adaptation to spaceflight.

Portable Pulmonary Function System (PPFS)↗

Chapter 8: Managing Safety Risk by Cell Manufacturers from the book Electrochemical Power Sources: Fundamentals, Systems, and Applications: Li-Battery Safety

Durability, reliability and safety are closely related in battery operation, requiring proper design to assure performance. To attain these properties are challenging and their issues of concerns need to be addressed in a coherent, holistic approach. For cell manufacturers, battery safety is about proper cell design. To implement effective safety measures, key is to engage failure mode and effect analysis in a sufficiently quantitative manner to understand cause-and-consequence relationship through advanced diagnostic and prognostic analyses to derive adequate cell design metrics to facilitate safe cell design. A key aspect of safety, not often discussed in the literature, is how to address it in the full context of electrochemical, thermal and mechanical balance. It is also important to realize that only when we can characterize the degree of tolerance and resilience to abuse, we are mature to know how to design a safe battery for operation.

25 ENERGY STORAGE↗

Environment assisted degradation mechanisms in aluminum-lithium alloys

Section 1 of this report records the progress achieved on NASA-LaRC Grant NAG-1-745 (Environment Assisted Degradation Mechanisms in Al-Li Alloys), and is based on research conducted during the period April 1 to November 30, 1987. A discussion of work proposed for the project's second year is included. Section 2 provides an overview of the need for research on the mechanisms of environmental-mechanical degradation of advanced aerospace alloys based on aluminum and lithium. This research is to provide NASA with the basis necessary to permit metallurgical optimization of alloy performance and engineering design with respect to damage tolerance, long term durability and reliability. Section 3 reports on damage localization mechanisms in aqueous chloride corrosion fatigue of aluminum-lithium alloys. Section 4 reports on progress made on measurements and mechanisms of localized aqueous corrosion in aluminum-lithium alloys. Section 5 provides a detailed technical proposal for research on environmental degradation of Al-Li alloys, and the effect of hydrogen in this.

Gangloff, Richard P.↗

National Launch System comparative economic analysis

Results are presented from an analysis of economic benefits (or losses), in the form of the life cycle cost savings, resulting from the development of the National Launch System (NLS) family of launch vehicles. The analysis was carried out by comparing various NLS-based architectures with the current Shuttle/Titan IV fleet. The basic methodology behind this NLS analysis was to develop a set of annual payload requirements for the Space Station Freedom and LEO, to design launch vehicle architectures around these requirements, and to perform life-cycle cost analyses on all of the architectures. A SEI requirement was included. Launch failure costs were estimated and combined with the relative reliability assumptions to measure the effects of losses. Based on the analysis, a Shuttle/NLS architecture evolving into a pressurized-logistics-carrier/NLS architecture appears to offer the best long-term cost benefit.

Prince, A.↗

Material and Design Optimization of Printed Melt Wire Arrays

Recent work conducted by the Advanced Sensors and Instrumentation (ASI) program at Idaho National Laboratory resulted in the establishment of in-house capabilities for fabricating and testing new advanced manufactured sensors for measuring irradiation temperatures inside a nuclear test reactor. Though current methods of real-time temperature monitoring (e.g., thermocouples) can still be used, the complexity of the feedthroughs and attachments needed for collecting real time measurements greatly increases the experiment-related costs. On the other hand, passive monitoring techniques can be used for collecting post irradiation temperature measurements by inferring reactor temperatures, based on the melting points of well-characterized materials (i.e., standard melt wires). However, challenges have arisen due to the limited space available for including instrumentation in experiments. To resolve this issue, the ASI program expanded its temperature detection capabilities to include advance manufactured melt wires for post-irradiation temperature measurements. These melt wires can determine reactor temperatures while also accommodating space limitations in irradiation experiments. To improve performance reliability and enhance melt wire readability following irradiation, FY-22 efforts have focused on optimizing the materials used in the encapsulation and printed melt wire array. This report details the design and fabrication tasks, along with the subsequent x ray computed tomography (XCT) evaluation process. The melt wire array consisted of indium with a melting point of 157°C, indium/silver (96/4 at%) with a melting point of 219°C, and tin with a melting point of 230°C. The encapsulation disc was made of vanadium due to its low activation properties and radiation resistance when deployed in nuclear reactors. Additionally, the melt wire design consisted of a ceramic sublayer (alumina disc) to further enhance the XCT post melting images of the printed melt wires. However, when sealing the vanadium container, all three melt wires melted, reflecting the temperature limitations that must be considered when employing metal containers in the sealing process.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Managing Safety Risk by Cell Manufacturers

Durability, reliability and safety are closely related in battery operation, requiring proper design to assure performance. To attain these properties are challenging and their issues of concerns need to be addressed in a coherent, holistic approach. For cell manufacturers, battery safety is about proper cell design. To implement effective safety measures, key is to engage failure mode and effect analysis in a sufficiently quantitative manner to understand cause-and-consequence relationship through advanced diagnostic and prognostic analyses to derive adequate cell design metrics to facilitate safe cell design. A key aspect of safety, not often discussed in the literature, is how to address it in the full context of electrochemical, thermal and mechanical balance. It is also important to realize that only when we can characterize the degree of tolerance and resilience to abuse, we are mature to know how to design a safe battery for operation.

25 ENERGY STORAGE↗

Antenna pattern study

Prediction of antenna radiation patterns has long been an important function in the design of command, communication, and tracking systems for rocket vehicles and spacecraft. An acceptable degree of assurance that a radio link will provide the required quality of data or certainty of correct command execution must be acquired by some means if the system is to be certified as reliable. Two methods have been used to perform this function: (1) Theoretical analysis, based on the known properties of basic antenna element types and their behavior in the presence of conductive structures of simple shape, and (2) Measurement of the patterns on scale models of the spacecraft or rocket vehicle on which the antenna is located. Both of these methods are ordinarily employed in the antenna design process.

Harper, Warren↗

ASTM Committee C28: International Standards for Properties and Performance of Advanced Ceramics-Three Decades of High-Quality, Technically-Rigorous Normalization

Physical and mechanical properties and performance of advanced ceramics and glasses are difficult to measure correctly without the proper techniques. For over three decades, ASTM Committee C28 on Advanced Ceramics, has developed high-quality, technically-rigorous, full-consensus standards (e.g., test methods, practices, guides, terminology) to measure properties and performance of monolithic and composite ceramics that may be applied to glasses in some cases. These standards contain testing particulars for many mechanical, physical, thermal, properties and performance of these materials. As a result these standards are used to generate accurate, reliable, repeatable and complete data. Within Committee C28, users, producers, researchers, designers, academicians, etc. have written, continually updated, and validated through round-robin test programs, 50 standards since the Committee's founding in 1986. This paper provides a detailed retrospective of the 30 years of ASTM Committee C28 including a graphical pictogram listing of C28 standards along with examples of the tangible benefits of standards for advanced ceramics to demonstrate their practical applications.

properties↗

In-Situ Measurement of the Height of Condensed Water in Steam Pipes with Dynamic Flow

A method based on the use of enhanced filtered Hilbert envelope of the wave signal was developed in order to monitor the height of condensed water through the wall of steam pipes having dynamic flow conditions. A prototype testbed was designed and fabricated in this study to simulate the dynamic flow conditions including the air stream flowing above the water and bubble induced disturbance. A dual-transducer was used to perform the test as a basis for the multiple transducers system to facilitate the detectability and reliability for long term monitoring of the condensed water height in dynamic conditions. The results demonstrated that the method of measuring the water height using multiple-transducer system employing the developed novel signal processing technique is an efficient and accurate tool for practical applications.

water level in pipe↗

RAPID AUTOMATED RADIOCHEMICAL ANALYZER FOR DETERMINATION OF TARGETED RADIONUCLIDES IN NUCLEAR PROCESS STREAMS

Some industrial process-scale plants require the monitoring of specific radionuclides as an indication of the composition of their feed streams or as indicators of plant performance. In this process environment, radiochemical measurements must be fast, accurate, and reliable. Manual sampling, sample preparation, and analysis of process fluids are highly precise and accurate, but tend to be expensive and slow. Scientists at Pacific Northwest National Laboratory (PNNL) have assembled and characterized a fully automated prototype Process Monitor instrument which was originally designed to rapidly measure Tc-99 in the effluent streams of the Waste Treatment Plant at Hanford, WA. The system is capable of a variety of tasks: extraction of a precise volume of sample, sample digestion / analyte redox adjustment, column-based chemical separations, flow-through radiochemical detection and data analysis / reporting. The system is compact, its components are fluidically inter-linked, and analytical results can be immediately calculated and electronically reported. It is capable of performing a complete analytical cycle in less than 15 minutes. The system is highly modular and can be adapted to a variety of sample types and analytical requirements. It exemplifies how automation could be integrated into reprocessing facilities to support international nuclear safeguards needs.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

Development of techniques for the in situ observation of OH and HO2 for studies of the impact of high-altitude supersonic aircraft on the stratosphere

This three-year project supported the construction, calibration, and deployment of a new instrument to measure the OH and HO2 radicals on the NASA ER-2 aircraft. The instrument has met and exceeded all of its design goals. The instrumentation represents a true quantum leap in performance over that achieved in previous HO(x) instruments built in our group. Sensitivity for OH was enhanced by over two orders of magnitude as the weight fell from approximately 1500 to less than 200 Kg. Reliability has been very high: HO(x) data are available for all flights during the first operational mission, the Stratospheric Photochemistry, Aerosols, and Dynamics Expedition (SPADE). The results of that experiment have been reported in the scientific literature and at conferences. Additionally, measurements of H2O and O3 were made and have been reported in the scientific literature. The measurements demonstrated the important role that OH and HO2 play in determining the concentration of ozone in the lower stratosphere. During the SPADE, campaign the measurements demonstrated that the catalytic removal is dominated by processes involving the odd-hydrogen and halogen radicals-and extremely important constraint for photochemical models that are being used to assess the potential deleterious effects of super-sonic aircraft effluent on the burden of stratospheric ozone.

Anderson, James G.↗

Development of techniques for the In Situ observation of OH and HO2 for studies of the impact of high-altitude supersonic aircraft on the stratosphere

This three-year project supported the construction, calibration, and deployment of a new instrument to measure the OH and HO2 radicals on the NASA Er-2 aircraft. The instrument has met and exceeded all of its design goals. The instrumentation represents a true quantum leap in performance over that achieved in previous HO(x) instruments built in our group. Sensitivity of OH was enhanced by over two orders of magnitude as the weight fell from approximately 1500 to less than 200 Kg. Reliability has been very high: HO(x) data are available for all flights during the first operational mission, the Stratospheric Photochemistry, aerosols, and Dynamics Expedition (SPADE). The results of that experiment have been reported in the scientific literature and at conferences. Additionally, measurements of H2O and O3 were made and have been reported in the scientific literature. The measurements demonstrate the important role that OH and HO2 play in determining the concentration of ozone in the lower stratosphere. During the SPADE campaign, the measurements demonstrate that the catalytic removal is dominated by processes involving the odd-hydrogen and halogen radicals-an extremely important constraint for photochemical models that are being used to assess the potential deleterious effects of super-sonic aircraft effluent on the burden of stratospheric ozone.

Anderson, James G.↗

Development of Techniques for the In Situ Observation of OH and HO2 for Studies of the Impact of High-Altitude Supersonic Aircraft on the Stratosphere

This three-year project supported the construction, calibration, and deployment of a new instrument to measure the OH and HO2 radicals on the NASA ER-2 aircraft. The instrument has met and exceeded all of its design goals. The instrumentation represents a true quantum leap in performance over that achieved in previous HO(x) instruments built in our group. Sensitivity for OH was enhanced by over two orders of magnitude as the weight fell from approximately 1500 to less than 200 Kg. Reliability has been very high: HO(x) data are available for all flights during the first operational mission, the Stratospheric Photochemistry, Aerosols, and Dynamics Expedition (SPADE). The results of that experiment have been reported in the scientific literature and at conferences. Additionally, measurements of H2O and O3 were made and have been reported in the scientific literature. The measurements demonstrate the important role that OH and HO2 play in determining the concentration of ozone in the lower stratosphere. During the SPADE campaign, the measurements demonstrate that the catalytic removal is dominated by processes involving the odd-hydrogen and halogen radical extremely important constraint for photochemical models that are being used to assess the potential deleterious effects of super-sonic aircraft effluent on the burden of stratospheric ozone. A list of the papers that came from this research are included, along with a copy of the paper, 'Aircraft-borne, laser-induced fluorescence instrument for the in situ detection of hydroxyl and hydroperoxyl radicals'.

Anderson, James G.↗

Advanced Power Electronics and Electric Machines

NLR's advanced power electronics and electric machines (APEEM) research group develops world-class experimental and modeling capabilities to design and evaluate efficient and reliable power electronics and electric machines, as well as innovative thermal management systems to maximize their performance. They also design, fabricate, and characterize advanced power electronics packaging and are developing state-of-health monitoring techniques.

25 ENERGY STORAGE↗

Performance and reliability of the NASA biomass production chamber

The Biomass Production Chamber (BPC) at the Kennedy Space Center is part of the Controlled Ecological Life Support System (CELSS) Breadboard Project. Plants are grown in a closed environment in an effort to quantify their contributions to the requirements for life support. Performance of this system is described. Also, in building this system, data from component and subsystem failures are being recorded. These data are used to identify problem areas in the design and implementation. The techniques used to measure the reliability will be useful in the design and construction of future CELSS. Possible methods for determining the reliability of a green plant, the primary component of CELSS, are discussed.

Fortson, R. E.↗

Performance and reliability of the NASA Biomass Production Chamber

The Biomass Production Chamber (BPC) at the Kennedy Space Center is part of the Controlled Ecological Life Support System (CELSS) Breadboard Project. Plants are grown in a closed environment in an effort to quantify their contributions to the requirements for life support. Performance of this system is described. Also, in building this system, data from component and subsystem failures are being recorded. These data are used to identify problem areas in the design and implementation. The techniques used to measure the reliability will be useful in the design and construction of future CELSS. Possible methods for determining the reliability of a green plant, the primary component of a CELSS, are discussed.

Sager, J. C.↗

Degradation in PV Encapsulation Transmittance: An Interlaboratory Study Towards a Climate-Specific Test: Preprint

Reduced optical transmittance of encapsulants resulting from ultraviolet (UV) degradation has frequently been identified as a cause of decreased PV module performance through the life of service in the field. The present module safety and qualification standards, however, apply short UV doses only capable of examining design robustness or 'infant mortality' failures. Essential information that might be used to screen encapsulation through product lifetime remains unknown. For example, the relative efficacy of xenon-arc and UVA-340 fluorescent sources or the typical range of activation energy for degradation is not quantified. We have conducted an interlaboratory experiment to provide the understanding that will be used towards developing a climate- and configuration-specific (UV) weathering test. Five representative, known formulations of EVA were studied in addition to one TPU material. Replicate laminated silica/polymer/silica specimens are being examined at 14 institutions using a variety of indoor chambers (including Xenon, UVA-340, and metal-halide light sources) or field aging. The solar-weighted transmittance, yellowness index, and the UV cut-off wavelength, determined from the measured hemispherical transmittance, are examined to provide understanding and guidance for the UV light source (lamp type) and temperature used in accelerated UV aging tests.

14 SOLAR ENERGY↗