Search NASA⌕ Search

SEARCH · Search NASA

Results for “Performance Deviation”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 163 records · Page 9

A comparison between anisotropic analytical and multigrid superposition dose calculation algorithms in radiotherapy treatment planning

Monte Carlo (MC) simulation is currently the most accurate dose calculation algorithm in radiotherapy planning but requires relatively long processing time. Faster model-based algorithms such as the anisotropic analytical algorithm (AAA) by the Eclipse treatment planning system and multigrid superposition (MGS) by the XiO treatment planning system are 2 commonly used algorithms. This study compared AAA and MGS against MC, as the gold standard, on brain, nasopharynx, lung, and prostate cancer patients. Computed tomography of 6 patients of each cancer type was used. The same hypothetical treatment plan using the same machine and treatment prescription was computed for each case by each planning system using their respective dose calculation algorithm. The doses at reference points including (1) soft tissues only, (2) bones only, (3) air cavities only, (4) soft tissue-bone boundary (Soft/Bone), (5) soft tissue-air boundary (Soft/Air), and (6) bone-air boundary (Bone/Air), were measured and compared using the mean absolute percentage error (MAPE), which was a function of the percentage dose deviations from MC. Besides, the computation time of each treatment plan was recorded and compared. The MAPEs of MGS were significantly lower than AAA in all types of cancers (p<0.001). With regards to body density combinations, the MAPE of AAA ranged from 1.8% (soft tissue) to 4.9% (Bone/Air), whereas that of MGS from 1.6% (air cavities) to 2.9% (Soft/Bone). The MAPEs of MGS (2.6%±2.1) were significantly lower than that of AAA (3.7%±2.5) in all tissue density combinations (p<0.001). The mean computation time of AAA for all treatment plans was significantly lower than that of the MGS (p<0.001). Both AAA and MGS algorithms demonstrated dose deviations of less than 4.0% in most clinical cases and their performance was better in homogeneous tissues than at tissue boundaries. In general, MGS demonstrated relatively smaller dose deviations than AAA but required longer computation time.

61 RADIATION PROTECTION AND DOSIMETRY↗

Stochastic Design Optimization of Microstructural Features Using Linear Programming for Robust Design

Microstructure design can have a substantial effect on the performance of critical components in numerous aerospace applications. However, the stochastic nature of metallic microstructures leads to deviations in material properties from the design point and alters the performance of these critical components. In this paper, a novel stochastic linear programming (LP) methodology is developed for microstructure design accounting for uncertainties in desired properties. The metallic microstructure is represented using a finite element discretized form of the orientation distribution function (ODF). The inverse LP problem solves the mean values and covariance matrix of the ODFs to maximize the mean values of a property, given the statistical constraints on other properties. The highlight is an analytical uncertainty quantification model via a Gaussian distribution to model propagation of microstructural uncertainties to the properties. Examples illustrate maximization of the yield strength and magnetostriction of a galfenol alloy when constrained by uncertainties in a set of stiffness constants.

42 ENGINEERING↗

Anomaly Detection in Partially Observed Traffic Networks

This paper addresses the problem of detecting anomalous activity in traffic networks where the network is not directly observed. Given knowledge of what the node-tonode traffic in a network should be, any activity that differs significantly from this baseline would be considered anomalous. We propose a Bayesian hierarchical model for estimating the traffic rates and detecting anomalous changes in the network. The probabilistic nature of the model allows us to perform statistical goodness-of-fit tests to detect significant deviations from a baseline network. We show that due to the more defined structure of the hierarchical Bayesian model, such tests perform well even when the empirical models estimated by the EM algorithm are misspecified. Finally, we apply our model to both simulated and real datasets to demonstrate its superior performance over existing alternatives.

97 MATHEMATICS AND COMPUTING↗

Radiotherapy Quality Assurance Report From Children's Oncology Group AHOD0031

Purpose: A phase 3 trial assessing response-based therapy in intermediate-risk Hodgkin lymphoma mandated real-time central review of involved field radiation therapy (IFRT) and imaging records by a centralized review center to maximize protocol compliance. We report the impact of centralized radiation therapy review on protocol compliance. Methods and Materials: Review of simulation films, port films, and dosimetry records was required before and after treatment. Records were reviewed by study-affiliated or review center–affiliated radiation oncologists. A deviation of 6% to 10% from protocol-specified dose was scored as “minor”; a deviation of >10% was “major.” A volume deviation was scored as “minor” if margins were less than specified or “major” if fields transected disease-bearing areas. Interventional review and final compliance review scores were assigned to each radiation therapy case and compared. Results: Of 1712 patients enrolled, 1173 underwent IFRT at 256 institutions in 7 countries. An interventional review was performed in 88% of patients and a final review in 98%. Overall, minor and major deviations were found in 12% and 6% of patients, respectively. Among the cases for which ≥1 pre-IFRT modification was requested by the Quality Assurance Review Center and subsequently made by the treating institution, 100% were made compliant on final review. By contrast, among the cases for which ≥1 modification was requested but not made by the treating institution, 10% were deemed compliant on final review. Conclusions: In a large trial with complex treatment pathways and heterogeneous radiation therapy fields, central review was performed in a large percentage of cases before IFRT and identified frequent potential deviations in a timely manner. When suggested modifications were performed by the institutions, deviations were almost eliminated.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Investigating the impact of atmospheric conditions on wake-steering performance at a commercial wind plant

Wake steering is a wind farm control strategy in which upstream wind turbines are misaligned with the wind to deflect their wakes away from downstream turbines, thereby increasing net energy production. But research suggests that the effectiveness of wake steering strongly depends on atmospheric conditions such as stability. In this paper, we investigate results from a two-turbine wake-steering experiment at a commercial wind plant to assess the impact of stability and five other atmospheric variables on wake-steering performance. Specifically, for different atmospheric condition bins we compare the ability of the controller to achieve the intended yaw offsets, the power gain from wake steering, and the reduction in wake losses. Further, we analyze wake-steering performance as a function of wind speed to eliminate the confounding impact of different wind speed distributions in different atmospheric conditions. Overall, we find that wind direction standard deviation is the best predictor of wake-steering performance, followed by turbulence intensity and turbulent kinetic energy. The results suggest the importance of adapting wake-steering control strategies to different atmospheric conditions.

17 WIND ENERGY↗

Examination of Factors Affecting the Cost and Performance of a Natural Gas Combined Cycle Equipped with Carbon Dioxide Capture

The purpose of this Technical Note is to report the findings of an examination of the effect of plausible deviations in select study assumptions on the reported cost and performance estimates for a power plant case drawn from NETL’s “Cost and Performance Baseline for Fossil Energy Plants Volume 1: Bituminous Coal and Natural Gas to Electricity” (known as the Fossil Energy Baseline). An F-Class NGCC power plant equipped with state-of-the-art, solvent-based, post-combustion carbon dioxide (CO2) capture (95 percent carbon capture rate)—designated as Case B31B.95—was selected for this work. This sensitivity analysis provides insight into the effects of parameter variations within and across selected categories—ambient conditions, construction cost, natural gas (NG) price, capacity factor, and finance—on the plant performance and capital and operating and maintenance (O&M) costs, and the subsequent impact on common figures of merit.

20 FOSSIL-FUELED POWER PLANTS↗

X-ray Intermolecular Structure Factor (XISF): separation of intra- and intermolecular interactions from total X-ray scattering data

XISF is a MATLAB program developed to separate intermolecular structure factors from total X-ray scattering structure factors for molecular liquids and amorphous solids. The program is built on a trust-region-reflective optimization routine with the r.m.s. deviations of atoms physically constrained. XISF has been optimized for performance and can separate intermolecular structure factors of complex molecules.

MATLAB↗

Long-term stability of the Leksell Gamma Knife{sup ®} Perfexion™ patient positioning system (PPS)

Purpose: To assess the long-term mechanical stability and accuracy of the patient positioning system (PPS) of the Leksell Gamma Knife{sup ®} Perfexion™ (LGK PFX). Methods: The mechanical stability of the PPS of the LGK PFX was evaluated using measurements obtained between September 2007 and June 2011. Three methods were employed to measure the deviation of the coincidence of the radiological focus point (RFP) and the PPS calibration center point (CCP). In the first method, the onsite diode test tool with single diode detector was used together with the 4 mm collimator on a daily basis. In the second method, a service diode test tool with three diode detectors was used biannually at the time of the routine preventive maintenance. The test performed with the service diode test tool measured the deviations for all three collimators 4, 8, and 16 mm and also for three different positions of the PPS. The third method employed the conventional film pin-prick method. This test was performed annually for the 4 mm collimator at the time of the routine annual QA. To estimate the effect of the patient weight on the performance of the PPS, the focus precision tests were also conducted with varying weights on the PPS using a set of lead bricks. Results: The average deviations measured from the 641 daily focus precision tests were 0.1 ± 0.1, 0.0 ± 0.0, and 0.0 ± 0.0 mm, respectively, for the 4 mm collimator in the X (left/right of the patient), Y (anterior/posterior of the patient), and Z (superior/inferior of the patient) directions. The average of the total radial deviations as measured during ten semiannual measurements with the service diode test tool were 0.070 ± 0.029, 0.060 ± 0.022, and 0.103 ± 0.028 mm, respectively for the central, long, and short diodes for the 4 mm collimator. Similarly, the average total radial deviations measured during the semiannual measurements for the 4, 8, and 16 mm collimators and using the central diode were 0.070 ± 0.029, 0.097 ± 0.025, 0.159 ± 0.028 mm, respectively. The average values of the deviations as obtained from the five annual film pin-prick tests for the 4 mm collimator were 0.10 ± 0.06, 0.06 ± 0.09, and 0.03 ± 0.03 mm for the X, Y, Z stereotactic directions, respectively. Only a minor change was observed in the total radial deviations of the PPS as a function of the simulated patient weight up to 202 kg on the PPS. Conclusions: Excellent long-term mechanical stability and high accuracy was observed for the PPS of the LGK PFX. No PPS recalibration or any adjustment in the PPS was needed during the monitored period of time. Similarly, the weight on the PPS did not cause any significant disturbance in the performance of the PPS for up to 202 kg simulated patient weight.

61 RADIATION PROTECTION AND DOSIMETRY↗

Characterization of cardiac quiescence from retrospective cardiac computed tomography using a correlation-based phase-to-phase deviation measure

Purpose: Accurate knowledge of cardiac quiescence is crucial to the performance of many cardiac imaging modalities, including computed tomography coronary angiography (CTCA). To accurately quantify quiescence, a method for detecting the quiescent periods of the heart from retrospective cardiac computed tomography (CT) using a correlation-based, phase-to-phase deviation measure was developed. Methods: Retrospective cardiac CT data were obtained from 20 patients (11 male, 9 female, 33–74 yr) and the left main, left anterior descending, left circumflex, right coronary artery (RCA), and interventricular septum (IVS) were segmented for each phase using a semiautomated technique. Cardiac motion of individual coronary vessels as well as the IVS was calculated using phase-to-phase deviation. As an easily identifiable feature, the IVS was analyzed to assess how well it predicts vessel quiescence. Finally, the diagnostic quality of the reconstructed volumes from the quiescent phases determined using the deviation measure from the vessels in aggregate and the IVS was compared to that from quiescent phases calculated by the CT scanner. Three board-certified radiologists, fellowship-trained in cardiothoracic imaging, graded the diagnostic quality of the reconstructions using a Likert response format: 1 = excellent, 2 = good, 3 = adequate, 4 = nondiagnostic. Results: Systolic and diastolic quiescent periods were identified for each subject from the vessel motion calculated using the phase-to-phase deviation measure. The motion of the IVS was found to be similar to the aggregate vessel (AGG) motion. The diagnostic quality of the coronary vessels for the quiescent phases calculated from the aggregate vessel (P{sub AGG}) and IVS (P{sub IV} {sub S}) deviation signal using the proposed methods was comparable to the quiescent phases calculated by the CT scanner (P{sub CT}). The one exception was the RCA, which improved for P{sub AGG} for 18 of the 20 subjects when compared to P{sub CT} (P{sub CT} = 2.48; P{sub AGG} = 2.07, p = 0.001). Conclusions: A method for quantifying the motion of specific coronary vessels using a correlation-based, phase-to-phase deviation measure was developed and tested on 20 patients receiving cardiac CT exams. The IVS was found to be a suitable predictor of vessel quiescence. The diagnostic quality of the quiescent phases detected by the proposed methods was comparable to those calculated by the CT scanner. The ability to quantify coronary vessel quiescence from the motion of the IVS can be used to develop new CTCA gating techniques and quantify the resulting potential improvement in CTCA image quality.

60 APPLIED LIFE SCIENCES↗

Creating Zipper‐Like van der Waals Gap Discontinuity in Low‐Temperature‐Processed Nanostructured PbBi 2 n Te 1+3 n : Enhanced Phonon Scattering and Improved Thermoelectric Performance

Abstract Nanoengineered materials can embody distinct atomic structures which deviate from that of the bulk‐grain counterpart and induce significantly modified electronic structures and physical/chemical properties. The phonon structure and thermal properties, which can also be potentially modulated by the modified atomic structure in nanostructured materials, however, are seldom investigated. Employed here is a mild approach to fabricate nanostructured PbBi 2 n Te 1+3 n using a solution‐synthesized PbTe‐Bi 2 Te 3 nano‐heterostructure as a precursor. The as‐obtained monoliths have unprecedented atomic structure, differing from that of the bulk counterpart, especially the zipper‐like van der Waals gap discontinuity and the random arrangement of septuple‐quintuple layers. These structural motifs break the lattice periodicity and coherence of phonon transport, leading to ultralow thermal conductivity and excellent thermoelectric z T .

Xu, Biao↗

Updated global SMEFT fit to Higgs, diboson and electroweak data

The ATLAS and CMS collaborations have recently released significant new data on Higgs and diboson production in LHC Run 2. Measurements of Higgs properties have improved in many channels, while kinematic information for h → γγ and h → ZZ can now be more accurately incorporated in fits using the STXS method, and W+W- diboson production at high pT gives new sensitivity to deviations from the Standard Model. We have performed an updated global fit to precision electroweak data, W+W- measurements at LEP, and Higgs and diboson data from Runs 1 and 2 of the LHC in the framework of the Standard Model Effective Field Theory (SMEFT), allowing all coefficients to vary across the combined dataset, and present the results in both the Warsaw and SILH operator bases. We exhibit the improvement in the constraints on operator coefficients provided by the LHC Run 2 data, and discuss the correlations between them. We also explore the constraints our fit results impose on several models of physics beyond the Standard Model, including models that contribute to the operator coefficients at the tree level and stops in the MSSM that contribute via loops.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Bubble Point Measurements of cis-1,1,1,4,4,4-Hexafluorobutene [R-1336mzz(Z)] + trans-1,2-Dichloroethene [R-1130(E)] mixtures

Saturation pressures of pure R-1336mzz(Z) and R-1130(E) and bubble point pressures of three R-1336mzz(Z)/1130(E) blends were measured from 265 K to 360 K. For each pure refrigerant or refrigerant blend, a total of twenty unique saturation pressures or bubble points were measured. In total 100 unique state points were obtained. Presently, no Helmholtz-energy-explicit type equation of state (EoS) is available for R-1130(E). While an extended corresponding states EoS for R-1130(E) is available to estimate the properties of the R-1336mzz(Z)/1130(E) blend, this model does not resolve the azeotropic behavior of the mixture. Therefore, the perturbed-chain statistical-associating fluid theory (PC-SAFT) EoS is used to model the vapor–liquid equilibria of the R-1336mzz(Z)/1130(E) blend. PC-SAFT model parameters are reported, and the overall performance of the model is characterized by deviations from the experimental data.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Fluorescence strobo-stereoscopy for specular reflection-suppressed full field of view imaging

This report introduces fluorescence strobo-stereoscopy (FSS) to suppress strong specular reflection and enable the full field of view (FFOV) 3D surface imaging while the part is rotating. Specular reflection off the target surface significantly degrades the image quality and becomes critical for highly reflective surface measurements. In FSS, the fluorescent dye-doped fluid applied on the machined surface is excited upon incident ultra-violet light and becomes a new light source by Stokes' Law. Thus, specular reflection off of smooth surface can be suppressed by separating the fluorescent light from the excitation light. The developed FSS comprises a pair of imaging cameras, spatial filters, and an excitation light source. As a result, FSS effectively rejected the specular reflection and improved the FFOV 3D surface image quality of the machined part by enhancing contrast in the rotating target surface. Such enhancements in 3D imaging allowed to identify manufacturing tolerance of the part and to detect the surface features. The axial and lateral accuracy errors of FSS were 2.3% and 1.4% with the target size of 4.07 mm and 0.215 mm, respectively. A whole view reconstruction of the cylindrical target sample was performed, and the corresponding cylindricity and diameter deviation were assessed. The fluid media effect and the target surface quality effect were discussed.

3D surface imaging↗

Tempering stochastic density functional theory

Here, we introduce a tempering approach with stochastic density functional theory (sDFT), labeled t-sDFT, which reduces the statistical errors in the estimates of observable expectation values. This is achieved by rewriting the electronic density as a sum of a "warm" component complemented by "colder" correction(s). Since the warm component is larger in magnitude but faster to evaluate, we use many more stochastic orbitals for its evaluation than for the smaller-sized colder correction(s). This results in a significant reduction in the statistical fluctuations and systematic deviation compared to sDFT for the same computational effort. We demonstrate the method's performance on large hydrogen-passivated silicon nanocrystals, finding a reduction in the systematic deviation in the energy by more than an order of magnitude, while the systematic deviation in the forces is also quenched. Similarly, the statistical fluctuations are reduced by factors of ≈4-5 for the total energy and ≈1.5-2 for the forces on the atoms. Since the embedding in t-sDFT is fully stochastic, it is possible to combine t-sDFT with other variants of sDFT such as energy-window sDFT and embedded-fragmented sDFT.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Network-Cognizant Design of Decentralized Volt/VAR Controllers

This paper considers the problem of designing decentralized Volt/VAR controllers for distributed energy resources (DERs). The voltage-reactive power characteristics of individual DERs are obtained by solving a convex optimization problem, where given performance objectives (e.g., minimization of the voltage deviations from a given profile) are specified and stability constraints are enforced. The resultant Volt/VAR characteristics are network-cognizant, in the sense that they embed information on the location of the DERs and, consequently, on the effect of reactive-power adjustments on the voltages throughout the feeder. Bounds on the maximum voltage deviation incurred by the controllers are analytically established. Numerical results are reported to corroborate the technical findings.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Fault-Tolerant Decentralized Control for Large-Scale Inverter-Based Resources for Active Power Tracking

Integration of inverter-based resources (IBRs) which lack the intrinsic characteristics such as the inertial response of the traditional synchronous-generator (SG)-based sources presents a new challenge in the form of analyzing the grid stability under their presence. While the dynamic composition of IBRs differs from that of the SGs, the control objective remains similar in terms of tracking the desired active power. This letter presents a decentralized primal-dual-based fault-tolerant control framework for the power allocation in IBRs. Overall, a hierarchical control algorithm is developed with a lower level addressing the current control and the parameter estimation for the IBRs and the higher level acting as the reference power generator to the low level based on the desired active power profile. The decentralized network-based algorithm adaptively splits the desired power between the IBRs taking into consideration the health of the IBRs transmission lines. The proposed framework is tested through a simulation on the network of IBRs and the high-level controller performance is compared against the existing framework in the literature. The proposed algorithm shows significant performance improvement in the magnitude of power deviation and settling time to the nominal value under faulty conditions as compared to the algorithm in the literature.

24 POWER TRANSMISSION AND DISTRIBUTION↗

SU-E-J-213: Imaging and Treatment Isocenter Verification of a Gantry Mounted Proton Therapy System

Purpose: The Mevion proton therapy machine is the first to feature a gantry mounted sychro-cyclotron. In addition, the system utilizes a 6D motion couch and kV imaging for precise proton therapy. To quantify coincidence between these systems, isocentricity tests were performed based on kV imaging alignment using radiochromic film. Methods: The 100 ton gantry and 6D robotic couch can rotate 190° around isocenter to provide necessary beam angles for treatment. The kV sources and detector panels are deployed as needed to acquire orthogonal portals. Gantry and couch mechanical isocenter were tested using star-shots and radiochromic-film (RCF). Using kV imaging, the star-shot phantom was aligned to an embedded fiducial and the isocenter was marked on RCF with a pinprick. The couch and gantry stars were performed by irradiating films at every 45° and 30°, respectively. A proton beam with a range and modulation-width of 18 cm was used. A Winston-Lutz test was also performed at the same gantry and couch rotations using a custom jig holding RCF and a tungsten ball placed at isocenter. A 2 cm diameter circular aperture was used for the irradiation. Results: The couch star-shot indicated a minimum tangent circle of 0.6 mm, with a 0.9 mm offset from the manually marked isocenter. The gantry star-shot showed a 0.6 mm minimum tangent circle with a 0.5 mm offset from the pinprick. The Winston Lutz test performed for gantry rotation showed a maximum deviation from center of 0.5 mm. Conclusion: Based on star-shots and Winston-Lutz tests, the proton gantry and 6D couch isocentricity are within 1 mm. In this study, we have shown that the methods commonly utilized for Linac characterization can be applied to proton therapy. This revolutionary proton therapy system possesses excellent agreement between the mechanical and radiation isocenter, providing highly precise treatment.

07 ISOTOPE AND RADIATION SOURCES↗

TU-C-12A-07: Characterization of Longitudinal Reproducibility of Quantitative Diffusion Imaging Data Acquired with Four Different Protocols Using a Phantom

Purpose: To characterize and compare the longitudinal reproducibility of diffusion imaging data acquired with four different protocols using a phantom. Methods: The Diffusive Quantitative Imaging Phantom (DQIP) was constructed using fifteen cylindrical compartments within a larger compartment, filled with deionized water doped with CuSO4 and NaCl. The smaller compartments contained arrays of hexagonal or cylindrical glass capillaries of varying inner diameters, for differing restraint of water diffusion. The sensitivity of diffusion imaging metrics to signal-to-noise ratio (SNR) was probed by doping compartments with differing ratios of deuterium oxide to H2O. A cork phantom enclosure was constructed to increase thermal stability during scanning and a cork holder was made to reproduce scanner positioning. Four different protocols of DWI (diffusion weighted imaging) and DTI (Diffusion tensor imaging) imaging were assembled on a GE Excite HDx 3.0T MRI scanner to collect imaging data over 9-10 days. Data was processed with in-house software created in Matlab to obtain fractional anisotropy (FA) and apparent diffusion coefficient (ADC) values. Results: All DTI and DWI sequences showed good longitudinal stability of mean FA and ADC values per compartment, exhibiting low standard deviation ∼9%. A t-test was performed to compare mean FA values from the DTI clinical protocol to those of the DTI special protocol, indicating significantly different values in the majority of compartments. ANOVA performed on ADC values for all DTI and DWI sequences also showed significantly different values in a majority of compartments. Conclusion: This work has the potential for quantifying systemic variations between diffusion imaging sequences from different platforms. Characterization of DWI and DTI performance were done over four sequences with predictable results. This data suggests that the DQIP phantom may be a reliable method of monitoring day-to-day and scan-to-scan variation in diffusion imaging sequences from different platforms. Schott Glass North America and The Phantom Laboratory have donated materials and personnel time to this project.

60 APPLIED LIFE SCIENCES↗