Search NASA⌕ Search

SEARCH · Search NASA

Results for “RADIOGRAPHY”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 163 records · Page 9

Assessing the Added Value of Miniature X-Ray in the Setting of US in Spaceflight

INTRODUCTION: Point-of-care ultrasound (POCUS) has become the standard of care for imaging diagnosis and management in lowEarth Orbit (LEO) spaceflight and it has long been hypothesized that POCUS will also be the standard of care for exploration spaceflight. However, like the trajectory for which ultrasound became more portable and user-friendly, the mass, volume, and power requirements of radiography devices for both diagnostic and therapeutic applications have also been dramatically reduced. This study seeks to determine the clinical utility and added value of miniature x-ray (XR) for the diagnosis and management of each of the 119 conditions within NASA Exploration Medical Capability’s IMPACT Condition List (ICL) given that the medical system is presumed to already be carrying a handheld portable POCUS device. METHODS: For each condition, a team of reviewers performed a rapid systematic literature review seeking sensitivity and specificity data for both handheld portable ultrasound and miniature XR. When there was a paucity of data, subject matter expertise and clinical experience was added to semi-quantitatively score the added value of miniature XR, given an US was already available for both diagnosis and management. Diagnostic utility of a modality for a condition was evaluated in the setting of both the best- and worst-case scenario definitions included and defined by the ICL. Evidence tracing and quality of evidence scores were also recorded. RESULTS/DISCUSSION: Conditions for which it was determined that miniature XR added diagnostic or therapeutic value are provided in this presentation. Previously presented work by our team has demonstrated that XR provides diagnostic and management capabilities that are hypothesized to complement or surpass ultrasound for over one-third of medical conditions that may arise during exploration spaceflight (i.e., diagnosis of injuries to the axial skeleton, teeth, and lungs as well as management of orthopedic reductions, endotracheal tube placement, and drain placement confirmation). In the setting of known inclusion of a handheld portable POCUS device, there remains significant added value of portable miniature XR. Whether or not this added clinical benefit is worth the mass, volume, and power requirements of the radiography system remains yet unknown and is the focus of future work. LEARNING OBJECTIVES: 1) Understand the value of ultrasound and radiography in the diagnosis and management of medical comorbidities that may arise in exploration spaceflight; 2) Understand the medical conditions of highest concern on exploration class missions for which miniature x-ray may provide added value to portable ultrasound.

Jon Steller↗

Time-Resolved Neutron Imaging for Hydrogen Uptake in Subsurface Lithologies

Geologic hydrogen production and underground storage are increasingly important for meeting rising energy demands while providing clean-combustion advantages. However, hydrogen’s high diffusivity and propensity for leakage through porous media necessitate direct evaluation of its transport behavior in subsurface materials. Whereas X-ray microcomputed tomography (μCT) studies often employ contrast agents or surrogate gases, this study leverages neutron transmission radiography/CT to observe hydrogen migration in situ. This work represents the first demonstration of real-time neutron radiography of hydrogen migration in reservoir and caprock lithologies. Cylindrical cores of Indiana limestone, Amherst Gray sandstone, and Tumey shale were subjected to constant-pressure hydrogen charging and scanned in real time using high-resolution neutron radiography. Results indicate immediate hydrogen infiltration in sandstone and limestone, with homogeneous distribution detected throughout their pore structure. In contrast, hydrogen remained largely absent from fine-grained shale under the same pressure, except in an apparently localized fracture zone, where neutron signatures confirmed the presence of hydrogen. Subsequent neutron CT of the sandstone sample, using image subtraction against an uncharged reference, corroborated hydrogen distribution patterns. Even under lowpressure, single-phase conditions, distinct neutron imaging signatures of hydrogen were achieved. These preliminary findings underscore the potential of neutron imaging for advancing subsurface hydrogen migration research.

08 HYDROGEN↗

Flow visualization in high-energy-density laboratory plasmas

Flow visualization is often essential for evaluating high-energy-density (HED) laboratory plasmas, examining their dynamics, and assessing design strategies. However, imaging at fine phenomenological flow scales is a major challenge. Here, a zone-plate–based radiography system tailored for applications in HED physics is demonstrated. The burst-mode radiography system combines a dual-flash laser-generated x-ray source, a high-magnification zone plate optic, and a multiple frame hybrid complementary metal-oxide-semiconductor (hCMOS) sensor for image detection. Operating at a magnification of 42 x⁠, a pair of radiographs is measured in rapid succession, each time gated by a 4.75 keV flash of x rays lasting 100 ps. The system achieves a spatial resolution below 3 μm. The potential of this approach for applications in HED physics is exemplified by observing small-scale spike morphologies at a pusher-foam interface impacted by a strong, laser-driven blast wave.

Flow instabilities↗

Diagnosing electric and magnetic fields in laser-driven coil targets

Laser-driven capacitor coils are widely used to generate intense magnetic fields for various applications in high-energy-density (HED) physics research. Accurate measurement of the magnetic fields is essential but challenging, due to the overlapping contributions from magnetic and electric fields in proton radiography, which is the primary tool diagnosing the field generation around the coils. In this study, we systematically analyze proton radiographs obtained from laser-driven capacitor-coil targets along two orthogonal axes under various electromagnetic field conditions, including magnetic field only, electric field only, and combined electromagnetic fields. By analyzing key features in the radiographs, we distinguish and characterize the respective contributions from magnetic and electric fields. Using detailed simulations validated by experimental benchmarks, methods to isolate and quantify the magnetic field and electric field are given. The methods are successfully applied to determine the electric current and charge distribution in a double coil configuration. Our findings provide insights into improving the diagnostic capability of proton radiography, potentially leading to more accurate measurements of electromagnetic fields and enhancing the utility of laser-driven capacitor coils in HED experiments.

electromagnetic field diagnostics↗

High spatial resolution neutron imaging of lithium-ion batteries: Correlating microstructure and lithium transport

Thick electrodes for lithium-ion batteries can increase the overall energy density, but increasing the electrode thickness introduces charge transport limitations. These limitations may be mitigated through proper electrode structuring. Here, high spatial resolution neutron imaging was used to understand the correlation between microstructure and lithium transport in lithium-ion anodes. Batteries with distinct graphite anode microstructures were produced and studied with high spatial resolution in operando neutron radiography to observe the effects of structure on transport. High spatial resolution neutron computed tomography was performed following in operando neutron radiography. X-ray computed tomography and scanning electron microscopy were used to observe the finer scale anode structure to complement neutron imaging. Solvent-free anodes containing a tightly-packed layered structure confined lithium movement close to the separator. This structure limited capacity, but supported better rate capability. Conversely, a more open pore structure in the wet cast anodes yielded higher capacity with reduced rate capability. Together, these results show that lithium distributions can be controlled by the macroscopic structure of the electrodes, the microstructural pore network, and the microscale active areas that support electrochemical reactions. Furthermore, multimodal imaging applying the complementary strengths of neutron and X-ray methods is shown as a tool for advancing battery design.

25 ENERGY STORAGE↗

Development of techniques for gantryless associated-particle imaging

To move fast-neutron radiography using the associated-particle imaging technique from the laboratory to the field, the development of new analysis techniques is required. In particular, the relative positions of the source and detectors need to be determined when they have been placed by hand, the normalization for a particular source–detector geometry needs to be determined without a measurement in the same geometry with no object present, and accurate image stitching is required when multiple detector positions are necessary to image an object. The present work describes methods that employ transmission neutron data to localize a fast-neutron imaging panel with respect to the neutron source, calculate a normalization for a given source–detector geometry, stitch images together, and describes the required system calibrations. The reported techniques enable in-field neutron radiography for cases in which the source–detector geometry is not well known a priori and where operational constraints preclude a normalization measurement.

Heath, Matthew↗

Irradiation of an enriched uranium (NaCl-UCl 3 ) fuel salt capsule, summary of nondestructive post-irradiation examinations, and solidification modeling

Molten salt reactors (MSRs) are gaining attention due to their potential for safe, carbon-free nuclear energy with reduced waste. However, licensing these reactors is hindered by limited experimental data on fueled salts, both pre- and post-irradiation. Here, the novel Molten-salt Research Temperature-controlled Irradiation (MRTI) vehicle was designed to address knowledge gaps in irradiating enriched‑uranium-bearing salts. The MRTI experiment irradiated 13 cm 3 of UCl₃-NaCl (93 % U-235) salt in the Neutron Radiography (NRAD) Reactor, achieving a burnup of 0.196 GWd/MTU over 390 h. Despite a heater failure, the thermocouple data suggested fission heat kept the salt molten. The MRTI assembly was remotely disassembled for nondestructive post-irradiation examination (PIE), which included precision gamma-ray scanning (PGS) and neutron radiography. Radiograph images showed the location of the salt and the solidification pattern. PGS results provided an early indication that activated materials of construction did not increase in relative intensity in the region of the capsule where the salt was in contact with the material of construction. Additionally, PGS data showed the presence of several gamma emitting fission products, such as Nb-95, Zr-95, Ru-103, Ce-141, and La-140, where Ru-103 had the highest counts at the bottom of the capsule. Computational fluid dynamics modeling supported observations of salt solidification patterns and proved to be a valuable tool to inform PIE activities. The MRTI experiment has thus far provided critical data and lessons learned for fuel salt PIE activities, essential for advancing the technical readiness of MSRs.

11 - NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

Quantifying motion blur by imaging shock front propagation with broadband and narrowband X-ray sources

Time-integrated radiography using MeV Bremsstrahlung X-ray sources is the norm for imaging during system-level testing of components and structures under dynamic condition. One source of error in the analysis of the time-integrated radiography data sets stems from motion blur which smears out sharp interfaces to a greater degree with longer exposure times, which become necessary to provide sufficient signal-to-noise with low X-ray penetration of objects of interest. To quantify motion blur, a 1D shock wave through PMMA was investigated experimentally at The Dynamic Compression Sector at The Advanced Photon Source (DCS@APS) with tapered broadband and 25.46 ± 1.06 keV narrowband X-rays. Four cameras with different exposure times were used for each experiment to compare the effect that exposure time has on motion blur. In addition, our methodology to accurately simulate motion blur in terms of transmission and shape is presented and compared to our experimental results and quantified. There is a high level of agreement between the experimental and simulation results across the range of data sets investigated in this study with a percent difference range of 0.29–1.31% for the four shots. The methodology of this work serves as a steppingstone towards a physically validated model that could be used in conjunction with experimental results to deconvolve physical parameters, densities, and interfaces of interest in a way that would not be possible with experimental results alone.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Learning robust parameter inference and density reconstruction in flyer plate impact experiments

Estimating physical parameters or material properties from experimental observations is a common objective in many areas of physics and material science. In many experiments, especially in shock physics, radiography is the primary means of observing the system of interest. However, radiography does not provide direct access to key state variables, such as density, which prevents the application of traditional parameter estimation approaches. Here we focus on flyer plate impact experiments on porous materials, and resolving the underlying parameterized equation of state (EoS) and crush porosity model parameters given radiographic observation(s). We use machine learning as a tool to demonstrate with high confidence that using only high impact velocity data does not provide sufficient information to accurately infer both EoS and crush model parameters, even with fully resolved density fields or a dynamic sequence of images. We thus propose an observable data set consisting of low and high impact velocity experiments/simulations that capture different regimes of compaction and shock propagation, and proceed to introduce a generative machine learning approach which produces a posterior distribution of physical parameters directly from radiographs. We demonstrate the effectiveness of the approach in estimating parameters from simulated flyer plate impact experiments, and show that the obtained estimates of EoS and crush model parameters can then be used in hydrodynamic simulations to obtain accurate and physically admissible density reconstructions. Finally, we examine the robustness of the approach to model mismatches, and find that the learned approach can provide useful parameter estimates in the presence of out-of-distribution radiographic noise and previously unseen physics, thereby promoting a potential breakthrough in estimating material properties from experimental radiographic images.

97 MATHEMATICS AND COMPUTING↗

Solidification cracking of laser melted commercial-purity tungsten

The high melting temperature of tungsten (W) makes it an attractive candidate for energy generation applications; however, its use is limited by its poor ductility at low temperatures. This limitation affects even melt-based additive manufacturing (AM) processes such as laser powder bed fusion (PBF-LB), with as-fabricated pure W exhibiting both longitudinal and transverse cracks. Metallurgical and processing factors that affect these cracks are still being explored. This work utilizes powderless single-tracks on pure W plates made over a range of power and velocity combinations in three unique PBF-LB setups: one with flowing argon, one with continuous vacuum, and an in situ high-speed synchrotron X-ray radiography setup. Each had different oxygen activities in their build environments. Longitudinal cracks with oxides appearing to exude from the crack were found for tracks deposited in a build environment with argon shield gas, while no such cracks were observed for builds conducted in vacuum. A calculation showed that direct oxygen ingress into the melt pool from the build environment is negligible when argon shield gas is present. Thus, incorporation of spatter is a likely mechanism for oxygen ingress into the melt pool. Radiography showed extensive keyholing, spatter generation, and crack formation at keyhole porosity. A heat transfer calculation showed the crack formation time was consistent with cooling below its ductile-to-brittle transition (DBT) temperature. This work identifies solidification cracking as a feasible mechanism in pure W beyond the well-known DBT related cracking.

Materials science↗

Characterization of a mock up nuclear waste package using energy resolved MeV neutron analysis

Reliable radiographic methods for characterizing nuclear waste packages non-destructively (without the need to open containers) have the potential to significantly contribute to safe handling and future disposal options, particularly for legacy waste of unknown content. Due to required shielding of waste containers and the need to characterize materials consisting of light elements, X-ray methods are not suitable. Here, energy-resolved MeV neutron radiography is demonstrated as a first-of-its-kind application for non-destructive and remote examination of mock up nuclear waste packages from a safe position using time-of-flight techniques enabled by a novel event-mode imaging detector system. Energy-resolved neutron transmission spectra were measured spatially, permitting the detection of analogue materials to actual nuclear waste such as water, melamine, and ion exchange resin within a 2.54 cm wall thickness steel pipe. The results demonstrate the capability to locate the materials through this wall thickness by radiography and tomographic reconstruction, revealing detailed 3D distributions and structural anomalies. The method effectively detects residual water in ion exchange resin, highlighting its sensitivity to moisture content, a crucial parameter for nuclear waste characterization. Monte Carlo simulations are in agreement with the experimental findings, providing a pathway to simulate waste forms more difficult to tackle experimentally. This work paves the way to apply sub-nanosecond intense MeV neutron sources, such as laser-driven neutron sources under development, to nuclear waste characterization.

36 MATERIALS SCIENCE↗

Examining astrophysical gas cloud collapse using an optical depth-scaled, x-ray-irradiated, carbon-foam sphere

When stellar radiation interacts with a molecular cloud, the cloud's fate depends on the strength of the incident radiation and the radiation's mean-free-path within the cloud [F. Bertoldi, Astrophys. J. 346, 735–755 (1989)]. Under the right conditions, the radiation compresses the cloud and a star formation may occur. Where and when the stellar formation occurs in the cloud's collapse are open questions. Direct observation of the complete star–cloud lifecycle is nearly impossible due to the immense timescales and distances over which the interaction occurs. Laboratory astrophysics offers a way to investigate such a system by scaling the important astrophysical parameters to the laboratory. This work describes laboratory experiments to study the radiation-driven implosion of clouds, using x rays from a laser-irradiated, thin, gold foil as a surrogate star and a carbon-foam sphere as a surrogate cloud. An optically thick system, theoretically corresponding to a star-forming regime, was selected by choice of the foam density. Gold foil and sphere motions were imaged by x-ray radiography. Radiographic images show the formation of an interface between rarefied gold and carbon plasmas, a shock moving into the sphere, and a blunting of the initial sphere's shape. Measurements show that the shock moved linearly around 64 μm/ns into the sphere, and the gold–carbon interface formed by 2 ns at the sphere edge remained stationary. The deformation of the sphere was driven by the incident radiation and not by mechanical pressures applied by gold plasma. The blunting of the sphere was likely due to the geometric reduction of flux near the sphere's poles. Higher x-ray flux near the sphere's equator caused high compression and a faster shock, which flattened the sphere. We will discuss the results and implications of our observations.

VanDervort, R. W. [University of Michigan 1 , Ann ↗

Structure of Self-Generated Magnetic Fields in Laser-Solid Interaction from Proton Tomography

Self-generated magnetic fields in laser-solid interactions are experimentally characterized to reveal the 3D location and local field strength, rather than path-integrated quantities, using multi-view proton radiography and tomographic inversion. We infer magnetic fields that extend several millimeters off the target into the hot, rarefied corona, sufficient to strongly magnetize the plasma (Ω e τ e ≫ 1). The data are compared to MHD simulations incorporating recent improvements in modeling magnetic field generation and transport; the volume-averaged coronal field strength and magnetic flux agree to within 25% using a model with magnetic re-localization of transport, although the near-target morphology is not reproduced. This work demonstrates tomographic proton radiography as a valuable tool for investigating magnetic fields in laser-produced plasmas.

High-energy-density plasmas↗

DARHT Axis 1 Bremsstrahlung Dose Measurements

he Dual-Axis Radiographic Hydrodynamic Test (DARHT) facility provides flash radiography ca pabilities using two electron Linear Induction Accelerators (LIA’s). Axis-1 of DARHT produces, nominally, a 20-MeV, 1.5-kA, 80-ns-Full Width at Half Max (FWHM) electron beam. The elec tron beam is focused on to a tantalum target to produce a Bremsstrahlung x-ray dose for flash radiography of dynamic systems. This paper will describe and compare a variety of techniques for determining the x-ray dose for two different beam currents produced by a 55mm and 70mm diameter cathode. The data was taken in November of 2022 on DARHT Axis 1. The experimen tal measurement techniques include a platinum calorimeter, a diamond radiation detector (DRD), and a Compton diode (CD). Gafchromic EBT3 self-developing dosimetry film was also used, but no useful results were obtained. Beam charge and energy were recorded and dose was calculated with this information using xtr with Dosecalcx, and simple dose charge-energy scaling. In this pa per, we will discuss the target geometry and experimental layout, the methods of measuring dose, dose diagnostics and measurement of beam charge and energy, and the comparisons of data and calculations.

43 PARTICLE ACCELERATORS↗

Locating tube blockage that X-ray cannot detect

Alternate choices to X-ray use in detecting foreign materials in metal assemblies are available, including negative radiography, neutron radiography, liquid-crystal inspection and ultrasonics. Advantages and disadvantages of each method are given. Report is valuable in testings and inspections, including heat exchangers and piping systems.

Hendron, J. A.↗

A comparison of screening techniques for ceramic capacitors

The techniques involved are ultrasonic scanning, neutron radiography, scanning laser acoustic microscopy, and voltage conditioning. The test capacitor, for this first phase, is a 0.47 uF, 50V capacitor style CKR06. Eighteen of 768 devices failed in voltage conditioning with elapsed times from 15 minutes to 1239 hours. Eleven of the failures were detected by ultrasonic scanning. Four failures were found by neutron radiography. Fourteen failures showed up in the acoustic microscopy test. Three failures in voltage conditioning were not detected by any of the techniques. Failures were confirmed by destructive physical analysis. There is no direct relationship between the size of the defect and electrical failure.

Kiernan, G. F.↗

NDE of structural ceramics

Radiographic, ultrasonic, scanning laser acoustic microscopy (SLAM), and thermo-acoustic microscopy techniques were used to characterize silicon nitride and silicon carbide modulus-of-rupture test specimens in various stages of fabrication. Conventional and microfocus X-ray techniques were found capable of detecting minute high density inclusions in as-received powders, green compacts, and fully densified specimens. Significant density gradients in sintered bars were observed by radiography, ultrasonic velocity, and SLAM. Ultrasonic attenuation was found sensitive to microstructural variations due to grain and void morphology and distribution. SLAM was also capable of detecting voids, inclusions and cracks in finished test bars. Consideration is given to the potential for applying thermo-acoustic microscopy techniques to green and densified ceramics. The detection probability statistics and some limitations of radiography and SLAM also are discussed.

Klima, S. J.↗

NDE of structural ceramics

Radiographic, ultrasonic, scanning laser acoustic microscopy (SLAM), and thermo-acoustic microscopy techniques were used to characterize silicon nitride and silicon carbide modulus-of-rupture test specimens in various stages of fabrication. Conventional and microfocus X-ray techniques were found capable of detecting minute high density inclusions in as-received powders, green compacts, and fully densified specimens. Significant density gradients in sintered bars were observed by radiography, ultrasonic velocity, and SLAM. Ultrasonic attenuation was found sensitive to microstructural variations due to grain and void morphology and distribution. SLAM was also capable of detecting voids, inclusions and cracks in finished test bars. Consideration is given to the potential for applying thermo-acoustic microscopy techniques to green and densified ceramics. The detection probability statistics and some limitations of radiography and SLAM also are discussed.

Klima, S. J.↗