Microwave radiometer and scatterometer design for the aquarius sea surface Salinity Mission

The measurement of sea surface salinity with L-band microwave radiometers is a very challenging task. Since the L-band brightness temperature variations associated with salinity changes are small, it is necessary to have a very sensitive and stable radiometer. In addition, the corrections for the ocean surface roughness require real time scatterometer measurements. The designs of the Aquarius radiometer and scatterometer are described in this paper.

sea surface salinity↗

Radio Frequency Interference Mitigation for the Planned SMAP Radar and Radiometer

NASA's planned SMAP mission will utilize a radar operating in a band centered on 1.26 GHz and a co-observing radiometer operating at 1.41 GHz to measure surface soil moisture. Both the radar and radiometer sub-systems are susceptible to radio frequency interference (RFI). Any significant impact of such interference requires mitigation in order to avoid degradation in the SMAP science products. Studies of RFT detection and mitigation methods for both the radar and radiometer are continuing in order to assess the risk to mission products and to refine the performance achieved.

radiometer↗

Imager-to-Radiometer In-flight Cross Calibration: RSP Radiometric Comparison with Airborne and Satellite Sensors

This work develops a method to compare the radiometric calibration between a radiometer and imagers hosted on aircraft and satellites. The radiometer is the airborne Research Scanning Polarimeter (RSP), which takes multi-angle, photo-polarimetric measurements in several spectral channels. The RSP measurements used in this work were coincident with measurements made by the Airborne Visible/Infrared Imaging Spectrometer (AVIRIS), which was on the same aircraft. These airborne measurements were also coincident with an overpass of the Landsat 8 Operational Land Imager (OLI). First we compare the RSP and OLI radiance measurements to AVIRIS since the spectral response of the multispectral instruments can be used to synthesize a spectrally equivalent signal from the imaging spectrometer data. We then explore a method that uses AVIRIS as a transfer between RSP and OLI to show that radiometric traceability of a satellite-based imager can be used to calibrate a radiometer despite differences in spectral channel sensitivities. This calibration transfer shows agreement within the uncertainty of both the various instruments for most spectral channels.

calibrating↗

Tracking Radiometer Calibration Stability Using Three-Point Onboard Calibration

Absolute calibration of radiometers is implemented onboard using one hot and one cold external calibration targets. However, two-point calibration methods are unable to differentiate calibration drifts and associated errors from fluctuations in receiver gain and offset. This paper investigates the use of onboard three-point calibration algorithm for microwave radiometers to track calibration drifts and characterize associated errors in Earth and Space measurements of the radiometer.

Calibration↗

Construction of the Bioconjugate Py‐Macrodipa‐PSMA and Its In Vivo Investigations with Large 132/135 La 3+ and Small 47 Sc 3+ Radiometal Ions

To harness radiometals in clinical settings, a chelator forming a stable complex with the metal of interest and targets the desired pathological site is needed. Toward this goal, we previously reported a unique set of chelators that can stably bind to both large and small metal ions, via a conformational switch. Within this chelator class, py-macrodipa is particularly promising based on its ability to stably bind several medicinally valuable radiometals including large 132/135 La 3+ , 213 Bi 3+ , and small 44 Sc 3+ . Here, in this study, we report a 10-step organic synthesis of its bifunctional analogue py-macrodipa-NCS, which contains an amine-reactive −NCS group that is amenable for bioconjugation reactions to targeting vectors. The hydrolytic stability of py-macordipa-NCS was assessed, revealing a half-life of 6.0 d in pH 9.0 aqueous buffer. This bifunctional chelator was then conjugated to a prostate-specific membrane antigen (PSMA)-binding moiety, yielding the bioconjugate py-macrodipa-PSMA, which was subsequently radiolabeled with large 132/135 La 3+ and small 47 Sc 3+ , revealing efficient and quantitative complex formation. The resulting radiocomplexes were injected into mice bearing both PSMA-expressing and PSMA-non-expressing tumor xenografts to determine their biodistribution patterns, revealing delivery of both 132/135 La 3+ and 47 Sc 3+ to PSMA+ tumor sites. However, partial radiometal dissociation was observed, suggesting that py-macrodipa-PSMA needs further structural optimization.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Atmospheric temperature, water vapour and liquid water path from two microwave radiometers during MOSAiC

The microwave radiometers HATPRO (Humidity and Temperature Profiler) and MiRAC-P (Microwave Radiometer for Arctic Clouds - Passive) continuously measured radiation emitted from the atmosphere throughout the Multidisciplinary drifting Observatory for the Study of the Arctic Climate (MOSAiC) expedition on board the research vessel Polarstern. From the measured brightness temperatures, we have retrieved atmospheric variables using statistical methods in a temporal resolution of 1 s covering October 2019 to October 2020. The integrated water vapour (IWV) is derived individually from both radiometers. In addition, we present the liquid water path (LWP), temperature and absolute humidity profiles from HATPRO. To prove the quality and to estimate uncertainty, the data sets are compared to radiosonde measurements from Polarstern. The comparison shows an extremely good agreement for IWV, with standard deviations of 0.08–0.19 kg m -2 (0.39–1.47 kg m -2 ) in dry (moist) situations. The derived profiles of temperature and humidity denote uncertainties of 0.7–1.8 K and 0.6–0.45 gm -3 in 0–2 km altitude.

54 ENVIRONMENTAL SCIENCES↗

Examination of Humidity and Ice Supersaturation Profiles Over West Antarctica Using Ground-Based G-Band Radiometer Retrievals

Humidity profiles retrieved from a ground-based millimeter-wave radiometer located at McMurdo Station, Antarctica and the West Antarctica Ice Sheet Divide are presented and their suitability to study the humidity of the polar climate is assessed. The dry conditions of the Antarctic winter and spring are ideal for ground-based millimeter-wave measurements and the retrievals appear to realistically reproduce the spatial and temporal variability of humidity at both sites. Furthermore, the radiometer has the ability to capture daily variability of very low humidity (0.5 to 4 g/kg) in the low-to-mid troposphere with an uncertainty of 10-20% during the Antarctic winter, spring, and summer. Despite the coarse vertical resolution (200-600 m in the first 4 km), the retrievals provide additional information with respect to the European Centre for Medium Range Weather Forecasts (ECMWF) profiles used as background information. The radiometer is also able to realistically identify the location and frequency of supersaturated layers with respect to ice in the mid troposphere. The occurrence of supersaturated layers is correlated with the occurrence of ice clouds identified by a cloud mask. Overall, results show that ground-based microwave and millimeter-wave radiometry is a viable complement to satellite observations to provide continuous information on the thermodynamic state of the low-to-mid troposphere at high latitudes.

54 ENVIRONMENTAL SCIENCES↗

Broadband and filter radiometers at Ross Island, Antarctica: detection of cloud ice phase versus liquid water influences on shortwave and longwave radiation

Abstract. Surface radiometer data from Ross Island, Antarctica, collected during the austral summer 2015–2016 by the US Department of Energy Atmospheric Radiation Measurement (ARM) program West Antarctic Radiation Experiment (AWARE), are used to evaluate how shortwave and longwave irradiance respond to changing cloud properties as governed by contrasting meteorological regimes. Shortwave atmospheric transmittance is derived from pyranometer measurements, and cloud conservative-scattering optical depth is derived from filter radiometer measurements at 870 nm. With onshore flow associated with marine air masses, clouds contain mostly liquid water. With southerly flow over the Transantarctic Mountains, orographic forcing induces substantial cloud ice water content. These ice and mixed-phase clouds attenuate more surface shortwave irradiance than the maritime-influenced clouds and also emit less longwave irradiance due to colder cloud base temperature. These detected irradiance changes are in a range that can mean onset or inhibition of surface melt over ice shelves. This study demonstrates how basic and relatively low-cost broadband and filter radiometers can be used to detect subtle climatological influences of contrasting cloud microphysical properties at very remote locations.

54 ENVIRONMENTAL SCIENCES↗

Development of a satellite microwave radiometer to sense the surface temperature of the world oceans

A proposed S-band radiometer for determining the ocean surface temperature with an absolute accuracy of + or - 1 Kelvin and a resolution of + or - .1 Kelvin was placed under the Advanced Applications Flight Experiment for further development into Nimbus readiness state. The results of assessing the following are described: effects due to the state of the sea surface, effects caused by the intervening atmosphere, and effects associated with imperfections in the instrument itself. An extensive sea truth program is also described for correlation of aircraft test flight measurements or of satellite remote measurement to in-situ data. An improved radiometer design is a modified Dicke-switch type with temperature stabilized, microwave integrated circuit, front-end and with a pulsed injection-noise nulling system. The radiometer has a multimode rectangular horn antenna with very low ohmic losses and a beam efficiency of 98% or better.

Hidy, G. M.↗

Studies with satellite radiometer data

The application of satellite radiometer data for analyzing and predicting global winds is discussed. The data obtained from the vertical temperature profile radiometer of the ITOS D satellite are described. The development of a nine level model for analyzing the physical properties of radiative transfer and cloud effects in the atmosphere is presented. Comparisons are made between various methods of applying the satellite radiometer data.

Halem, M.↗

High performance S-band horn antennas for radiometer use

Horn antennas of four types: pyramidal corrugated, conical corrugated, pyramidal dual mode and conical dual mode, have been constructed and evaluated for use as S-band radiometer antennas. Each of the structures is described and radiation patterns and impedance and resistive loss measurements including a layer of foreign material on a thin radome, are presented. A precision method for determining reflection losses is described using a multiprobe reflectometer technique. The same technique is also applied to the measurement of resistive losses by closing the ends of the antennas with short circuit plates and determining the losses from an accurate measurement of the reflection coefficient. The radiation patterns were recorded with the aid of a real-time digital computer. The stored patterns were then processed to yield gain and beam efficiency. It was concluded that it is possible to design a highly efficient antenna for radiometer use and to measure its parameters precisely. However, it was found that it is necessary to modify the conventional definition of beamwidth somewhat if this term is to be meaningful for radiometer applications.

Caldecott, R.↗

Design and performance characteristics of the Vertical Temperature Profile Radiometer /VTPR/ for atmospheric temperature soundings.

Description of the design and operation of a radiometer which derives atmospheric temperature profiles on the basis of spectral measurements in eight optical filter channels. The radiometer achieves its eight-channel capability by sequentially viewing the eight optical filters mounted in a rotating filter wheel, with a single IR detector and electronic amplification channel processing the signal for all the filters. The advantages and disadvantages of this sequential approach as compared to eight 'parallel' radiometric channels are discussed. The proposed radiometer provides a relative calibration accuracy between seven out of the eight channels of better than 0.1% rms of the full dynamic range. The absolute accuracy achievable between in-flight calibrations of six minutes, or between two-hour calibrations using optical temperature correction factors, is better than an rms value of 0.15% of full scale. The radiometric correlation between the in-flight calibration source of the instrument and a reference standard blackbody is better than an rms value of 0.5% of full scale.

Falbel, G.↗

Correcting airborne scanning infrared radiometer measurements for atmospheric effects

Two techniques were developed for determining atmospheric corrections from observations made by a scanning radiometer. Both techniques depend on knowing the radiometer's limb function. The limb function for an RS-18 scanning radiometer is derived from calculations made with a radiation model and used to demonstrate the techniques. One technique requires observations made over an isothermal water surface within the area being remotely sensed. The other technique does not depend on an isothermal water surface but requires a boat measurement of radiometric sea surface temperature within the area being remotely sensed. The radiation model used to derive the limb function does not account for the effects of atmospheric particulates on the correction. It is hypothesized that the effect of particulates on the limb function derived in this study is negligible, and therefore the technique essentially obtains the total correction. The techniques developed can be used over land provided that a section of isothermal land exists within the experiment area or that a radiometric measurement of surface temperature is made at the surface.

Boudreau, R. D.↗

Dual frequency microwave radiometer measurements of soil moisture for bare and vegetated rough surfaces

Controlled ground-based passive microwave radiometric measurements on soil moisture were conducted to determine the effects of terrain surface roughness and vegetation on microwave emission. Theoretical predictions were compared with the experimental results and with some recent airborne radiometric measurements. The relationship of soil moisture to the permittivity for the soil was obtained in the laboratory. A dual frequency radiometer, 1.41356 GHz and 10.69 GHz, took measurements at angles between 0 and 50 degrees from an altitude of about fifty feet. Distinct surface roughnesses were studied. With the roughness undisturbed, oats were later planted and vegetated and bare field measurements were compared. The 1.4 GHz radiometer was less affected than the 10.6 GHz radiometer, which under vegetated conditions was incapable of detecting soil moisture. The bare surface theoretical model was inadequate, although the vegetation model appeared to be valid. Moisture parameters to correlate apparent temperature with soil moisture were compared.

Lee, S. L.↗

Remote sensing of soil moisture with microwave radiometers

Microwave radiometry has been used for the remote sensing of soil moisture in a series of aircraft flights over an agricultural test area in the vicinity of Phoenix, Arizona. The radiometers covered the wavelength range 0.8-21 cm. Ground truth in the form of gravimetric measurements of the soil moisture in the top 15 cm were obtained for 200 fields at this site. The results indicate that it is possible to monitor moisture variations with airborne radiometers. The emission is a function of the radiometer wavelength and the distribution of the moisture in the soil. At a wavelength of 1.55 cm there is little or no variation in the emission for soil moisture values below 10 or 15% moisture content by weight. Above this value, there is a linear decrease in the emission with a slope of approximately 3 K for each percentage point increase in soil moisture.

Schmugge, T.↗

A balloon-borne cryogenically cooled filter radiometer

The development of a cryogenically cooled filter radiometer for use with high altitude balloons is discussed. The radiometer has features which include the options for remote operation of two filter wheels each containing six filters at helium temperature and a cryogenic rotary chopper which may be run at 200 cycles per second or positioned open or closed, and a remotely operable chopped blackbody calibration source. The radiometer contains a ten inch diameter liquid nitrogen cooled Cassegrain telescope with nine individually filtered field stops in the focal plane. The telescope is mounted on a two-axis servo operated gimbal which is used to make sky scans under the control of an onboard programmer.

Debell, A. G.↗

Steady-state solution to the conduction problem of a spherical balloon radiometer, phases 1 and 2

A satellite system proposed for observing the earth's radiation balance employing spherical balloon radiometers is investigated. In the steady-state condition of radiative equilibrium, the magnitudes of absorbed external irradiances are sensed by internal radiometers mounted on the skin of each balloon. The temperatures of the radiometers are monitored as a measure of the balloons' internal irradiances (equal to absorbed external irradiances) and telemetered to earth. The effect of the magnitude of irradiant sources, balloon thickness, and thermal conductivity on the conduction of heat is assessed mathematically in order to determine its impact on measurement accuracy. Results indicate that observations are acceptable during daytime and nighttime modes of operation.

House, F. B.↗

Antennas for spaceborne microwave radiometers

Principles and applications of microwave radiometry to remote sensing of the earth from satellites are reviewed. Examples of some spaceborne radiometer systems currently in use or under consideration are given. The requirements on performance characteristics of microwave antennas for such spaceborne earth sensing radiometers, such as coverage, scanning, spatial resolution, insertion loss, beam efficiency, polarization purity, etc., and their effects on the overall radiometer system performance are discussed.

Shiue, J. C.-C.↗