Search NASA⌕ Search

SEARCH · Search NASA

Results for “Reliability and Integrity Management”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 163 records · Page 9

Decentralized wind uncertainty management: Alternating direction method of multipliers based distributionally-robust chance constrained optimal power flow

How to manage wind power uncertainty in system operation is an urgent and important issue, especially under substantially increasing penetration levels of wind generation in electric power systems. With increasing numbers of wind power plants (WPPs) integrated into power systems, their variability and uncertain power outputs become a challenge to maintaining system reliability. Traditional stochastic optimization-based models face the curse of dimensionality when the number of WPPs increases. This paper proposes a novel decentralized wind power uncertainty management model. In this model, conventional generators optimize their power capacity output and their participation to mitigate wind power uncertainty locally with only limited information exchange with the system operators. First, a distributionally-robust chance-constrained optimal power flow (DRCC-OPF) model is deployed to schedule the generation and reserve considering the wind power forecast uncertainty. Then, the alternating direction method of multipliers (ADMM) is used to reformulate the DRCC-OPF model into the distributed optimization model for each conventional generator and WPP. The tests on a small PJM 5-bus system and the IEEE 118-bus system demonstrate that the proposed decentralized model can increase the operation reliability without sacrificing system operating cost, especially when the wind power penetration levels are high. Using the proposed model, the optimal solutions can be obtained within one minute, for all studied cases, which verifies the computation efficiency of the proposed decentralized model. Furthermore, considering a large number of WPPs integrated into the system, the proposed decentralized method obtains a lower operating cost within one minute which demonstrates its efficiency to deal with high dimension of uncertainties.

17 WIND ENERGY↗

High Temperature Optocoupler for 3D High Density Power Modules

The goal of this proposed research is to develop a reliable high-temperature optocouplers, which can operate at 250°C with at least ten-year lifetime, and replace isolation transforms as the galvanic isolation solution for the 3D integration of high density power modules. The electrification of future transportations (i.e., electric vehicles) will continuously drive the demand for high density power modules. Optocouplers (i.e., packaged light emitter and detector) as a promising candidate to replace bulky isolation transformers are highly desirable to facilitate the continuous scale-down of gate driver circuitry that will lead to 3D high density power modules and achieve disruptive performance in terms of thermal management, power density, power efficiency, reliability and operating environments. However, regular semiconductor optoelectronic materials and devices have significant difficulty functioning in the harsh environments designated for high density power module usage (such as operation at high temperatures). Ultimately, it is not the intrinsic properties of power devices that prevent their use at higher temperatures, but rather the low voltage electronics needed to drive them and the packaging that surrounds them. The typical operating temperature for optocouplers is only up to 100°C, due to the limitations of light emitting diode (LED) devices inside and packaging materials. A systematic characterization methodology will be developed to analyze the performance, lifetime and reliability of LED devices and distinguish multiple failure mechanisms at high temperatures. An original methodology of “design for reliability” will be developed to design the optoelectronic devices with high reliability and long lifetime at high temperatures. A new architecture of high temperature high reliable optocouplers will be developed, fabricated and demonstrated with continuous operating at 250°C. The development of efficient, reliable high density 3D power modules is the foundation for energy efficiency and energy reliability. Enabled with advanced 3D integration and packaging technologies, high density power module solutions can achieve much more superior performance over the conventional discrete solutions in terms of efficiency, thermal management and power density. The proposed concept of high temperature optocouplers as the galvanic isolation solution for high density power modules will bring together interdisciplinary research involving the wide bandgap materials, optoelectronics, high reliable device design, electronics packaging and power modules. A streamline of skilled personnel would be trained including graduate and undergraduate students, local engineers and scientists which are in great demand to both academia and optoelectronics industry. The proposed research topics, such as, solid state lighting and high temperature device reliability, are currently of major interest at the Department of Energy, in particular, Sandia National Laboratories. This project can enhance collaborations between the University of Arkansas (UA) and Sandia National Laboratories. The findings of the proposed research are expected to be integrated into high density 3-D power modules at the Engineering Research Center for Power Optimization for Electro-Thermal Systems (POETS).

42 ENGINEERING↗

Opportunities for Improving Photovoltaic Performance with Better Transparent Contacts

NREL and DOE recently held a workshop to assess the challenges, opportunities and potential impacts for improved transparent contacts (TCs) to positively impact current and emerging photovoltaic conversion technologies. Here, we report on the workshop outcomes based on the collective input and participation from industry, academia, national laboratories and DOE. A primary conclusion is that new emerging materials can have significant impacts on the overall performance, reliability and cost for commercial scale PV. One key observation is that TC's should no longer be thought of as a single-layer single-purpose material but as an integrated contact layer stack that includes a charge selective interface layer, a conducting layer and sometimes layers for reliability or light management. In addition, the long standing goal of developing of high performance atmospheric-pressure-processed TCs has finally been met by the rapidly improving Ag nanowire based composites with better than ITO performance from an all ink based process. Even the more conventional metal oxide materials are improving rapidly by introducing solution processed buffer layers, and even conductor layers. This rapid evolution has opened the way to high-throughput low-cost TC processing. Key desired metrics for TCs and approaches to achieving them are discussed.

14 SOLAR ENERGY↗

Prototype thin-film thermocouple/heat-flux sensor for a ceramic-insulated diesel engine

A platinum versus platinum-13 percent rhodium thin-film thermocouple/heat-flux sensor was devised and tested in the harsh, high-temperature environment of a ceramic-insulated, low-heat-rejection diesel engine. The sensor probe assembly was developed to provide experimental validation of heat transfer and thermal analysis methodologies applicable to the insulated diesel engine concept. The thin-film thermocouple configuration was chosen to approximate an uninterrupted chamber surface and provide a 1-D heat-flux path through the probe body. The engine test was conducted by Purdue University for Integral Technologies, Inc., under a DOE-funded contract managed by NASA Lewis Research Center. The thin-film sensor performed reliably during 6 to 10 hr of repeated engine runs at indicated mean surface temperatures up to 950 K. However, the sensor suffered partial loss of adhesion in the thin-film thermocouple junction area following maximum cyclic temperature excursions to greater than 1150 K.

Kim, Walter S.↗

Hybrid Power Management

An engineering discipline denoted as hybrid power management (HPM) has emerged from continuing efforts to increase energy efficiency and reliability of hybrid power systems. HPM is oriented toward integration of diverse electric energy-generating, energy-storing, and energy-consuming devices in optimal configurations for both terrestrial and outer-space applications. The basic concepts of HPM are potentially applicable at power levels ranging from nanowatts to megawatts. Potential applications include terrestrial power-generation, terrestrial transportation, biotechnology, and outer-space power systems. Instances of this discipline at prior stages of development were reported (though not explicitly labeled as HPM) in three prior NASA Tech Briefs articles: "Ultracapacitors Store Energy in a Hybrid Electric Vehicle"(LEW-16876), Vol. 24, No. 4 (April 2000), page 63; "Photovoltaic Power Station With Ultracapacitors for Storage" (LEW-17177), Vol. 27, No. 8 (August 2003), page 38; and "Flasher Powered by Photovoltaic Cells and Ultracapacitors" (LEW-17246), Vol. 24, No. 10 (October 2003), page 37. As the titles of the cited articles indicate, the use of ultracapacitors as energy-storage devices lies at the heart of HPM. An ultracapacitor is an electrochemical energy-storage device, but unlike in a conventional rechargeable electrochemical cell or battery, chemical reactions do not take place during operation. Instead, energy is stored electrostatically at an electrode/electrolyte interface. The capacitance per unit volume of an ultracapacitor is much greater than that of a conventional capacitor because its electrodes have much greater surface area per unit volume and the separation between the electrodes is much smaller. Power-control circuits for ultracapacitors can be simpler than those for batteries, for two reasons: (1) Because of the absence of chemical reactions, charge and discharge currents can be greater than those in batteries, limited only by the electrical resistances of conductors; and (2) whereas the charge level of a battery depends on voltage, temperature, age, and load condition, the charge level of an ultracapacitor, like that of a conventional capacitor, depends only on voltage.

Eichenberg, Dennis↗

Bridging Equipment Reliability Data and Risk Informed Decisions in a Plant Operation Context

Industry equipment reliability and asset management programs are essential elements that help ensure the safe and economical operation of nuclear power plants. The effectiveness of these programs is addressed in several industry-developed and regulatory programs. The Risk-Informed Asset Management (RIAM) project is tasked to develop tools in support of the equipment reliability and asset management programs at nuclear power plants. These tools are designed to create a direct bridge between component health/lifecycle data and decision making (e.g., maintenance scheduling and project prioritization). The goal of this article is to provide a guide for specific use cases that the RIAM project is targeting. We have grouped uses cases into three main areas. The first area focuses on the analysis of equipment reliability data with a particular emphasis on condition-based data, such as test/surveillance reports and component monitoring data. The second area focuses on the integration of equipment reliability into system/plant reliability models to determine system/plant health and identify the components that are critical to maintain an operational system. Lastly, the third area manages plant resources, such as maintenance activities and replacement scheduling using optimization methods. Here the primary focus is on supporting typical system engineer decisions regarding maintenance activity scheduling and component aging management. This is performed in a risk-informed context where the term “risk” is broadly constructed to include both plant reliability and economics. This framework combines data analytics tools to analyze equipment reliability data with risk-informed methods designed to support system engineer decisions (e.g., maintenance and replacement schedules, optimal maintenance posture) in a customizable workflow.

97 - MATHEMATICS AND COMPUTING↗

Exploring the Use of Muon Momentum for Detection of Nuclear Material Within Shielded Spent Nuclear Fuel Dry Casks

The inspection of the storage containers that house used nuclear fuel is an important issue facing the nuclear industry; currently, there are limited options available to provide for even minimal inspections. During the long storage life of the fuel, intermediate handling and transportation activities may take place that can create concerns regarding fuel integrity (safety) and continuity of knowledge (safeguards and security). Accidents and natural disasters also contribute to this concern. The reliable and safe management of used nuclear fuel is among the critical tasks to be addressed for the advancement of fission-based nuclear energy in the United States and elsewhere. Since the early 1950's, when the first nuclear power plant began to produce electricity, approximately 65,000 metric tons of used nuclear fuel have been generated in the United States. The postponement of the opening of a permanent repository until 2048 will lead to increased used fuel accumulation at reactor sites. A rapid increase in storage installations with more than 9,000 casks storing {approx}420,000 assemblies is anticipated by 2050 even if no new nuclear power plants are built. After used nuclear fuel has been placed inside a cask, the cask is sealed, not allowing for visual inspection. Conventional methods, e.g., x-rays, are limited in that they cannot penetrate dense, well-shielded objects. More sophisticated techniques, such as penetrating neutrons or proton radiography, require the use of an expensive accelerator. Efforts by Ziock et al. using neutron and gamma-ray imagers concluded that '...the signatures are deemed insufficient to uniquely identify individual casks of the same type...'. It was found that the gamma-ray and neutron images were dominated by diffusion and thermalization effects resulting from the large amount of shielding. One promising mode of inspection would use cosmic-ray muons. These muons are naturally generated, are able to penetrate dense materials, and are incident from all directions above the horizon. Tomography performed using these muons could potentially provide efficient, inexpensive, remote assessment of used nuclear fuel. However, current muon applications are limited in that they have not included momentum measurement. If momentum measurement could be incorporated, that would represent a big step forward because it would allow more accurate estimation of the muon observables, e.g., scattering variance. This approach has the potential to reconstruct the contents of a cask with improved resolution and identify partial defects, fuel assemblies, and individual fuel rods.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Impact Analysis of Data Integrity Attacks on FACTS-based Wide-Area Voltage Control System

Energy management system (EMS) consists of several wide-area control applications that serve as a backbone for security, stability, and reliability of the power system. Wide-area voltage control system (WAVCS), one of the critical wide-area applications, operates in coordination with local Flexible AC Transmission System (FACTS) devices to provide voltage security and optimal management of active and reactive power resources. Since the WAVCS relies on wide-area communication and data sharing devices, possible cybersecurity vulnerabilities have to be addressed to ensure the closed-loop operation of WAVCS. In this paper, we present a methodology for performing an impact analysis of cyber-attacks in WAVCS cybersecurity. In particular, different types of data integrity attacks, such as malicious tripping, fault replay, and signal altering attacks, are considered, and detailed impact analysis is conducted in a testbed environment using the Kundur's four machine two-area system. For performing an impact analysis, the transient voltage stability of the sensitive bus voltage is studied, followed by the quantitative assessment and severity ranking using the voltage profile index. Our experimental evaluation reveals that the data integrity attacks on control signals exhibit a higher attack severity than on the measurement signals. Further, the severity of these attacks varies with nature (static or dynamic), location, and types of attacks.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Space station software reliability analysis based on failures observed during testing at the multisystem integration facility

Quality of software not only is vital to the successful operation of the space station, it is also an important factor in establishing testing requirements, time needed for software verification and integration as well as launching schedules for the space station. Defense of management decisions can be greatly strengthened by combining engineering judgments with statistical analysis. Unlike hardware, software has the characteristics of no wearout and costly redundancies, thus making traditional statistical analysis not suitable in evaluating reliability of software. A statistical model was developed to provide a representation of the number as well as types of failures occur during software testing and verification. From this model, quantitative measure of software reliability based on failure history during testing are derived. Criteria to terminate testing based on reliability objectives and methods to estimate the expected number of fixings required are also presented.

Tamayo, Tak Chai↗

SIGHT: Stacked Integration of Geospatial Hierarchical Typologies for Inferring Building Characteristics

Building characteristics are often absent in building stock datasets, particularly in regions most vulnerable to climate change and requiring effective disaster management strategies. Traditional machine learning approaches, while widely used to predict building attributes, typically neglect the spatial context of the data, leading to less accurate and reliable outcomes. To address these challenges, this paper introduces a novel algorithm, the Stacked Integration of Geospatial Hierarchical Typologies. This algorithm adapts a meta-learning framework to incorporate geospatial context into the predictive modeling process. We demonstrate the utility of the algorithm through two primary use cases: building use type classification and building height prediction. The algorithm consistently achieved or exceeded a 0.94 macro average F1 score across five geographically distinct countries for building use type classification. For building height prediction, it accurately predicted heights with a root mean square error of 3.01 in a comprehensive study using roughly 3.6 million buildings in Japan. These results underscore the benefits of integrating spatial hierarchies into machine learning models, enhancing both predictive accuracy and reliability in geospatial modeling. This work introduces a new algorithm to address the pervasive data sparsity issue in existing building stock datasets.

Adams, Daniel [ORNL] (ORCID:0000000196950577)↗

Automated Demand Response: The Missing Link in the Electricity Value Chain

In 2006, the Public Interest Energy Research Program (PIER) Demand Response Research Center (DRRC) at Lawrence Berkeley National Laboratory initiated research into Automated Demand Response (OpenADR) applications in California industry. The goal is to improve electric grid reliability and lower electricity use during periods of peak demand. The purpose of this research is to begin to define the relationship among a portfolio of actions that industrial facilities can undertake relative to their electricity use. This ?electricity value chain? defines energy management and demand response (DR) at six levels of service, distinguished by the magnitude, type, and rapidity of response. One element in the electricity supply chain is OpenADR, an open-standards based communications system to send signals to customers to allow them to manage their electric demand in response to supply conditions, such as prices or reliability, through a set of standard, open communications. Initial DRRC research suggests that industrial facilities that have undertaken energy efficiency measures are probably more, not less, likely to initiate other actions within this value chain such as daily load management and demand response. Moreover, OpenADR appears to afford some facilities the opportunity to develop the supporting control structure and to"demo" potential reductions in energy use that can later be applied to either more effective load management or a permanent reduction in use via energy efficiency. Under the right conditions, some types of industrial facilities can shift or shed loads, without any, or minimal disruption to operations, to protect their energy supply reliability and to take advantage of financial incentives.1 In 2007 and 2008, 35 industrial facilities agreed to implement OpenADR, representing a total capacity of nearly 40 MW. This paper describes how integrated or centralized demand management and system-level network controls are linked to OpenADR systems. Case studies of refrigerated warehouses and wastewater treatment facilities are used to illustrate OpenADR load reduction potential. Typical shed and shift strategies include: turning off or operating compressors, aerator blowers and pumps at reduced capacity, increasing temperature set-points or pre-cooling cold storage areas and over-oxygenating stored wastewater prior to a DR event. This study concludes that understanding industrial end-use processes and control capabilities is a key to support reduced service during DR events and these capabilities, if DR enabled, hold significant promise in reducing the electricity demand of the industrial sector during utility peak periods.

29 ENERGY PLANNING, POLICY, AND ECONOMY↗

Opportunities for Joint Water–Energy Management: Sensitivity of the 2010 Western U.S. Electricity Grid Operations to Climate Oscillations

The 2016 SECURE Water Act report’s natural water availability benchmark, combined with the 2010 level of water demand from an integrated assessment model, is used as input to drive a large-scale water management model. The regulated flow at hydropower plants and thermoelectric plants in the Western U.S. electricity grid (WECC) is translated into potential hydropower generation and generation capacity constraints. The impact on reliability (unserved energy, reserve margin) and cost (production cost, carbon emissions) of water constraints on 2010-level WECC power system operations is assessed using an electricity production cost model (PCM). Use of the PCM reveals the changes in generation dispatch that reflect the inter-regional interdependencies in water-constrained generation and the ability to use other generation resources to meet all electricity loads in the WECC. August grid operational benchmarks show a range of sensitivity in production cost (-8 to +11%) and carbon emissions (-7 to 11%). The reference reserve margin threshold of 15% above peak load is maintained in the scenarios analyzed, but in 5 out of 55 years unserved energy is observed when normal operations are maintained. There is 1 chance in 10 that a year will demonstrate unserved energy in August, which defines the system’s historical performance threshold to support impact, vulnerability, and adaptation analysis. For seasonal and longer term planning, i.e., multi-year drought, we demonstrate how the Water Scarcity Grid Impact Factor and climate oscillations (ENSO, PDO) can be used to plan for joint water-electricity management to maintain grid reliability.

adaptation↗

Enabling Ultra-Compact, Lightweight, Efficient, and Reliable 6.6 kW On-Board Bi-Directional Electric Vehicle Charger with Advanced Topology and Control

The research explored new topologies, control methods, mechanical integration, and thermal management methods for electric vehicle (EV) on-board chargers. The team investigated capacitor-based power conversion, leveraging the high energy densities inherent to capacitive energy storage compared to inductive methods. The proposed topologies simultaneously enabled high power density and high efficiency of the design. The proposed architecture was demonstrated in a 6.6 kW bi-directional charger prototype. The research pursued several directions to improve system performance. Innovative topologies were studied for both the main power conversion stage as well as the single-phase twice-line-frequency energy buffer. To ensure robust and efficient operation, new control methods were developed to integrate these two subsystems. To achieve high power density in the full system solution, the mechanical structure of the charger is highly optimized to maximally fill the converter box volume. In parallel with the mechanical design effort, the converter was packaged with high-performance cooling methods which removed heat from key areas of power dissipation in the converter. The thermal management system was optimized to minimize its weight and volume, ultimately motivating the design of a custom additively manufactured cold-plate. The full system achieves a peak power of 7 kW with less than 0.3% total harmonic distortion (THD) and greater than 0.994 power factor in power factor correction (PFC) operation, corresponding to a total box-volume power density of 47.9 kW/L and gravimetric power density of 24.6 W/g. The system achieves a peak efficiency of 98.9%, with 97.9% efficiency at maximum power.

33 ADVANCED PROPULSION SYSTEMS↗

Low-Cost Scaffold-Reinforced Perovskite Solar Modules with Integrated Light Management

Perovskite solar cells are a promising new solar technology because they are highly efficient and cheaper to manufacture compared to silicon solar cells. However, perovskites suffer from mechanical and thermal fragility, important factors limiting device lifetimes, which leads to problems in making reliable solar cells. In our recent work, we showed how to make perovskite solar cells that look like the eye of a fly by subdividing a solar cell into thousands of microcells that are surrounded by a honeycomb-shaped reinforcing scaffold. This discovery was a new architecture called a compound solar cell (CSC). The perovskite is effectively shielded from mechanical forces by the scaffold and leads to robust solar cells that are no longer fragile. This was a promising advancement, but the drawback of the scaffold structure is that the scaffold absorbs light from the solar cell and leads to a reduced efficiency. In this project, we address this reduced efficiency by integrating concentrating lens arrays into CSCs to focus any incident light away from the scaffolds. Perovskite is deposited into the microcells between these scaffolds, and upon sunlight exposure, the lenses concentrate light into the microcells and away from the insulating scaffolds, resulting in significantly improved efficiencies. The lenses redirect over 90% of the light that otherwise would have been incident on the scaffolds into the microcells leading to a corresponding 90% recovery of efficiency. Furthermore, the lenses show passive light tracking capabilities, meaning as the angle of incident light changes (simulating how the sunlight moves across the sky during the course of the day), a majority of the light is still focused into the perovskite microcells. The improved efficiency and passive tracking capabilities suggest that lens-integrated CSCs are a potential pathway to high-performance, robust, commercially viable perovskite solar cells.

14 SOLAR ENERGY↗

Electric Access System Enhancement (EASE): Assessment of a Distributed Energy Resource Management System for Enabling Dynamic Hosting Capacity

The Electric Access System Enhancement (EASE) project demonstrated a scalable, interoperable, and cost-effective means of integrating high penetration of distributed energy resources (DERs). The control architecture developed leveraged a Distributed Energy Resource Management System, Distribution System Operator for transacting energy, and 3rd Party DER Aggregator platform. The project identified ways to enhance the customer interconnection process to the grid and improve access to information from DERs and optimize the usage of DERs to provide energy services in a simulated day-ahead shadow market while maintain grid reliability. By integrating these capabilities into a scalable system of systems, the DSO can effectively balance DER generation and customer demand on the distribution network. This capability allows the grid to host more DER than traditionally possible on wires alone. Hosting more DER has the added benefit of supplying increased demand growth, sometimes beyond the capacity limits of the distribution network itself. This is known as a dynamic hosting capacity, which could help utilities manage the forecasted growth in electricity demand as California switch to electric vehicles and appliances. This could help to establish energy storage and PV generation as a “pseudo firm” generation resource mix if managed appropriately and provide sufficient resource adequacy for distribution capacity upgrade deferrals.

14 SOLAR ENERGY↗

A Review of Quantum Computing Technologies in Power System Optimization

As modern power grids increasingly integrate variable renewable generation, distributed energy resources, and energy storage systems, classical optimization techniques are facing unprecedented challenges. This review examines the emerging application of quantum computing to overcome these challenges in power system optimization, including optimal power flow (OPF), unit commitment (UC), economic dispatch (ED), and intelligent switching and topology optimization (IS-TO). Recent research has introduced various quantum methodologies—such as gate-based, annealing-based, variational algorithms, and quantum-inspired algorithms—to address the combinatorial complexity inherent in grid reconfiguration and energy management. The review summaries the quantum algorithms, quantum devices and the power system test cases, highlighting hybrid quantum–classical strategies that leverage the complementary strengths of both paradigms. Some quantum advantages have been observed, including theoretical speedup, accurate simulation results, scalable qubit usage, efficient QUBO mapping. In particular, the review emphasizes the importance of integrating quantum optimization techniques with classical control frameworks, these hybrid approaches demonstrate the potential to improve real-time grid management and operational reliability. A significant portion of the analysis is devoted to the practical limitations of current quantum devices. Present-day quantum hardware, operating in the noisy intermediate-scale quantum (NISQ) era, remains highly sensitive to noise and limited in qubit connectivity, which constrains the scale and accuracy of implemented algorithms. The review delves into specific challenges such as the need for qubit-efficient encoding techniques and error mitigation strategies that are critical for handling real-world grid optimization problems. In addition, the work draws attention to the performance discrepancies between theoretical quantum speedups and experimental validations, underscoring the importance of rigorous benchmark studies using representative power grid test cases. In summary, this review highlights both the promise and limitations of quantum computing for power system optimization. It provides a comprehensive overview of the state-of-the-art technologies, categorizes recent advancements in algorithm design, and discusses practical considerations for implementation, and serves as an informative resource on current research. Future research directions include developing robust hybrid frameworks, advancing qubit-efficient formulations, and scaling up experimental demonstrations to confirm the theoretical advantages of quantum methods in large-scale power system operations.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Automated Inventory Solutions in End-User IT Support

Managing IT equipment by hand is prone to errors and delays, severely impacting operational continuity and productivity. Manual inventory systems often result in time delays, inconsistent record-keeping, equipment shortages, and increased workloads for IT staff. At Savannah River National Laboratory (SRNL), my internship focused on creating an automated inventory management solution using Microsoft Power Automate and SharePoint Lists. This solution seamlessly integrates with the existing Microsoft 365 infrastructure, thus eliminating the need for additional software purchases or dedicated server space. By providing real-time updates and reducing manual data entry, the new system ensures a more reliable and maintainable approach to IT asset management.

Information Technology↗

Laboratory testing methods to evaluate the reliability of occupancy sensors for commercial building applications

The energy performance of commercial buildings is greatly influenced by occupants which are highly variable and among the most unpredictable components of a building's operation. While most building control systems use fixed, predetermined occupancy schedules, these fixed occupancy levels can be quite different from actual occupancy. This can cause unnecessary energy consumption, particularly from heating, ventilation, and air conditioning (HVAC) and lighting systems which are responsible for approximately 60% of commercial buildings' energy use. The use of occupancy counting sensor systems integrated with building management system controls is one method that can be used to improve the energy-consuming performance of buildings. However, there is no standardized universal methodology and metrics to evaluate their reliability. The aim of this research is to develop a uniform evaluation methodology to assess the reliability of occupancy counting sensor systems in a controlled laboratory environment. The developed testing methodology includes both “typical” scenarios representing the occupancy scenarios of a typical commercial building, and “failure” testing scenarios which represent a range of potential scenarios that may impact a sensor system's reliability. These methods were then implemented in a case study to evaluate the performance of two novel occupancy counting sensor systems (i.e., door-centric, and camera-based). Results suggest that typical testing results can be used to compare the overall performance of the occupancy counting sensor systems; however, failure testing is also important to understand the weaknesses of the sensor system in order to select the suitable one for the intended use of the commercial building. In addition, the proposed methodology includes a modified confusion matrix which enables the ability to identify if failures are caused by over or under counting occupants and to what extent this occurs over the testing period.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗