Search NASA⌕ Search

SEARCH · Search NASA

Results for “SHOT NOISE”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 163 records · Page 9

External Radiation and Magnetic-Field Effects on the Coherence and Stability of Transmon Qubits

Superconducting transmon qubits are a central building block of modern quantum computing architectures, yet their coherence properties remain sensitive to external influences that can limit performance or introduce temporal instabilities. In this talk, I will discuss two experimental studies aimed at quantifying these effects. First, I will examine how ionizing radiation impacts qubit relaxation. Using the same transmon device operated at two locations with dramatically different radiation backgrounds—the above-ground SQMS facility at Fermilab (USA) and the deep-underground Gran Sasso Laboratory (Italy)—we observe a higher rate of radiation-induced decay events above ground, even though intrinsic noise remains the dominant source of single-shot errors. I will also discuss the detection efficiency of a radiation detector made using such a device. Second, I will present results on how small magnetic fields, applied either during cooldown or at millikelvin temperatures, influence device stability. We find that fixed-frequency transmons maintain robust coherence up to approximately 600 mG of trapped out-of-plane field, and that controlled application of magnetic field can reduce temporal fluctuations in T1. Together, these studies provide insight into how external environments shape transmon coherence and offer potential pathways for improving qubit stability in scalable quantum processors.

Roy, Tanay [Fermilab]↗

Unsupervised anomaly detection in MeV ultrafast electron diffraction

MeV ultrafast electron diffraction (MUED) is a pump-probe technique used to study the dynamic structural evolution of materials. An ultrashort laser pulse triggers structural changes, which are then probed by an ultrashort relativistic electron beam. To overcome low signal-to-noise ratios, diffraction patterns are averaged over thousands of shots. However, shot-to-shot instabilities in the electron beam can distort individual patterns, introducing uncertainty. Improving MUED accuracy requires detecting and removing these anomalous patterns from large datasets. In this work, we developed a fully unsupervised methodology for the detection of anomalous diffraction patterns. Using a convolutional autoencoder, we calculate the reconstruction mean squared error of the diffraction patterns. Based on the statistical analysis of this error, we provide the user an estimation of the probability that the pattern is normal, which also allows a posterior visual inspection of the images that are difficult to classify. This method has been trained with only 100 diffraction patterns and tested on 1521 patterns, resulting in a false positive rate between 0.2% and 0.4%, with a training time of 10 s per image and a test time of about 1 s per image. Here, the proposed methodology can also be applied to other diffraction techniques in which large datasets are collected that include faulty images due to instrumental instabilities.

43 PARTICLE ACCELERATORS↗

Proof-of-concept Talbot–Lau x-ray interferometry with a high-intensity, high-repetition-rate, laser-driven K-alpha source

Talbot–Lau x-ray interferometry is a grating-based phase-contrast technique, which enables measurement of refractive index changes in matter with micrometric spatial resolution. The technique has been established using a variety of hard x-ray sources, including synchrotron, free-electron lasers, and x-ray tubes, and could be used in the optical range for low-density plasmas. The tremendous development of table-top high-power lasers makes the use of high-intensity, laser-driven K-alpha sources appealing for Talbot–Lau interferometer applications in both high-energy-density plasma experiments and biological imaging. To this end, we present the first, to the best of our knowledge, feasibility study of Talbot–Lau phase-contrast imaging using a high-repetition-rate laser of moderate energy (100 mJ at a repetition rate of 10 Hz) to irradiate a copper backlighter foil. The results from up to 900 laser pulses were integrated to form interferometric images. A constant fringe contrast of 20% is demonstrated over 100 accumulations, while the signal-to-noise ratio continued to increase with the number of shots. Phase retrieval is demonstrated without prior ex-situ phase stepping. Instead, correlation matrices are used to compensate for the displacement between reference acquisition and the probing of a PMMA target rod. The steps for improved measurements with more energetic laser systems are discussed. The final results are in good agreement with the theoretically predicted outcomes, demonstrating the applicability of this diagnostic to a range of laser facilities for use across several disciplines.

Bouffetier, V. (ORCID:0000000160791260)↗

Scalable Parallel Measurement of Individual Nitrogen-Vacancy Centers

The nitrogen-vacancy (NV) center in diamond is a solid-state spin defect that has been widely adopted for quantum sensing and quantum information processing applications. Typically, experiments are performed either with a single isolated NV center or with an unresolved ensemble of many NV centers, resulting in a trade-off between measurement speed and spatial resolution or control over individual defects. In this work, we introduce an experimental platform that bypasses this trade-off by addressing multiple optically resolved NV centers in parallel. We perform charge- and spin-state manipulations selectively on multiple NV centers from within a larger set, and we manipulate and measure the electronic spin states of over 100 NV centers in parallel. We show that the high signal-to-noise ratio of the measurements enables the detection of shot-to-shot pairwise correlations between the spin states of 108 NV centers, corresponding to the simultaneous measurement of 5778 unique correlation coefficients. We discuss how our platform can be scaled to parallel experiments with thousands of individually resolved NV centers. These results enable parallelized high-throughput sensing experiments that retain the spatial resolution of single defects and will, thereby, help to unlock advances in applications such as single-molecule NMR and characterization of integrated circuits. In addition, our approach to multiplexing provides a natural platform for the application of recently developed correlated sensing techniques.

NV centers↗

Single-Shot Diagnostics of Microbunched Electrons in Laser-Driven Plasma Accelerators and Free-Electron Lasers

aThe need for single-shot diagnostics of the periodic longitudinal density modulation of relativistic electrons at the resonant wavelength (microbunching) in a free-electron laser (FEL) or at broadband visible wavelengths as in a laser-driven plasma accelerator (LPA) has been reaffirmed. In the self-amplified spontaneous emission (SASE) FEL case, statistical fluctuations in the microbunching occur in the startup- from-noise process. In the LPA, the plasma itself is chaotic and varies shot to shot. Fortunately, we have shown that coherent optical transition radiation (COTR) techniques, can assess beam size, divergence, spectral evolution, and z-dependent gain (100,000) of microbunched electrons in a past SASE FEL experiment at 530 nm*. Recently, the application to LPAs has been demonstrated with single-shot near-field (NF) and far-field (FF) COTR imaging done at the exit of an LPA for the first time**. In this case few-micron beam sizes and extensive fringes due to su b-mrad divergences were measured based on point-spread-function effects and an analytical model for COTR interferometry (COTRI), respectively. A new COTR-based diagnostics application to pre-bunched electron beams formed by co-propagating a laser pulse and the electron pulse in a short undulator (modulator) is also described.

43 PARTICLE ACCELERATORS↗

Impulse Noise Sampling at 9965 - Armag

One detonation test was monitored for impulse noise at Thunder Range on November 6, 2020. The TNT equivalency for this shot was 100 lbs. Ground zero for this test was located at an open area of Range 7. The Armag, where MOW were remotely located, was just south of the east end of the TR shock tube The purpose of this sampling event was to characterize the noise attenuation provided by the Armag which will be used as the primary firing location in a future test series. To determine attenuation provided by the Armag, one sound level monitor was placed inside and a second monitor was placed outside the hardened structure at the same distance from ground zero. The Armag was located 1300 feet from ground zero. Essential personnel performing these tests were remotely located inside the Armag and wore hearing protection with a minimum NRR of 23. Members of the Workforce (MOW) who are exposed to noise levels above 140 dBC, regardless of hearing protection worn, are required to be enrolled into the SNL Hearing Conservation Program which includes audiometric testing, online training (HCP100) and wearing hearing protection.

42 ENGINEERING↗

Neutron calorimeter development at fission and fusion pulsed neutron sources

A neutron calorimeter fielded in pulsed neutron irradiation experiments at the National Ignition Facility (NIF) and White Sands Missile Range Fast Burst Reactor (WSMR FBR) is described, and results are provided and discussed. The calorimeter is modular in design to allow fielding of various neutron absorber materials and thicknesses, as well as use at both fission and fusion sources, all of which has been done. Neutron calorimeters designed for fission sources have been fielded at fusion sources as well, but these instances are not documented in available literature—making this work novel. The functional calorimeter consists of a neutron absorber and two sheathed, grounded thermocouples secured within a subassembly made of thermally insulating materials. This subassembly is placed into a sealed vessel for material and facility safety considerations. The device was fielded at NIF in four polar-direct-drive exploding pusher shots and eleven WSMR FBR pulses. Calorimeter data from NIF experiments show a discernable thermal response accredited to neutron heating within the first 10 s, but the data are dominated by noise from ambient X-ray heating after time = 10 s post-pulse. This response is highly consistent between shots and linearly related to incident neutron fluence and neutron absorber thickness. A temperature rise of 1.1E-2 K/(10 13 neutrons/cm 2 ) per millimeter of absorber thickness was determined for both 0.4 mm and 1 mm thick depleted uranium absorbers with linear best fit R 2 of 0.97 and 0.98 for each thickness and y-axis offsets of 8.8E-3 and 1.3E-2, respectively. WSMR FBR experiment data show a temperature rise of 6.2E-2 K/(10 13 neutrons/cm 2 ) with linear best fit R 2 of 0.14 and y-axis offset of 7.6E-3 for a calorimeter with a 1 mm thick enriched boron carbide ( 10 B 4 C) absorber, though it must be noted that device-to-device variability is significant at both facilities. So these data are also affected by noise on a similar timescale as at NIF, though the noise is significantly lesser in magnitude but oscillatory.

42 ENGINEERING↗

Visual Fixations in Basketball Shooting: Differences between Shooting Conditions

Basketball is a sport where shooting is one of the most important factors that determines the success or failure of the teams. Therefore, basketball players need to shoot the ball accurately. The present study aimed to evaluate whether different shooting conditions influence the visual behavior of athletes. For this, the Tobbi Pro Glasses 3 equipment was used to evaluate the time of the first fixation, the number of fixations, and the total time of fixations in the basket, during the shooting movement. Different distances to the basket, simulated gym audience noise, and shooting with opposition were considered. A group of 18 athletes with an average age of 22 ± 3.72 years and an average basketball practice experience of 12.5 ± 4.52 years performed 10 valid shots from different distances and different shooting angles, with different restrictions, namely, shooting with simulated opposition and gym audience noise. Statistically significant differences between shooting with opposition and baseline, in terms of the number of fixations and the total time of fixation, were found. Regarding shooting with gym audience noise, differences only occur for the total time of fixations in one position. Despite this, in all variables and positions, the values were lower in shooting with constraints compared to the baseline.

Amaro, Catarina M. (ORCID:0000000303343503)↗

Optimizing the sensitivity of high repetition rate broadband transient optical spectroscopy with modified shot-to-shot detection

A major limitation of transient optical spectroscopy is that relatively high laser fluences are required to enable broadband, multichannel detection with acceptable signal-to-noise levels. Under typical experimental conditions, many condensed phase and nanoscale materials exhibit fluence-dependent dynamics, including higher order effects such as carrier–carrier annihilation. With the proliferation of commercial laser systems, offering both high repetition rates and high pulse energies, have come new opportunities for high sensitivity pump-probe measurements at low pump fluences. However, experimental considerations needed to fully leverage the statistical advantage of these laser systems have not been fully described. Here, we demonstrate a high repetition rate, broadband transient spectrometer capable of multichannel shot-to-shot detection at 90 kHz. Importantly, we find that several high-speed cameras exhibit a time-domain fixed pattern noise resulting from interleaved analog-to-digital converters, which is particularly detrimental to the conventional “ON/OFF” modulation scheme used in pump-probe spectroscopy. Using a modified modulation and data processing scheme, we achieve a noise level of 10−5 in 4 s for differential transmission, an order of magnitude lower than for commercial 1 kHz transient spectrometers for the same acquisition time. We leverage the high sensitivity of this system to measure the differential transmission of monolayer graphene at low pump fluence. We show that signals on the order of 10−6 OD can be measured, enabling a new data acquisition regime for low-dimensional materials.

47 OTHER INSTRUMENTATION↗

Measurement of Magnetic Field using Doppler-Free Saturation Spectroscopy (DFSS) in C-2W FRC Plasma

The Cooperative Research and Development Agreement (CRADA) between Oak Ridge National Laboratory (ORNL) and TAE Technologies (TAE) focused on implementing an existing mobile Doppler-free saturation spectroscopy (DFSS) diagnostic to determine the direction of the equilibrium magnetic field within TAE’s C-2W field-reversed configuration (FRC) fusion device. Non-perturbative measurements of magnetic fields in the core of FRCs can provide critical information needed to constrain equilibrium models and for the continued advancement of the fusion research program at TAE. DFSS is a well-established, laser-based absorption spectroscopy technique used to suppress inhomogeneous (Doppler) broadening and reveal the Zeeman fine structure of the target emission lines. The collaboration involved the use of ORNL’s recently constructed mobile DFSS diagnostic. The DFSS diagnostic was shipped and installed on C- 2W in February 2023. TAE’s expertise was used to design and construct the mechanic support structures required to mount the optical hardware on C-2W. Additionally TAE provide critical input to minimize the noise imposed on the DFSS signal by vibrations of the mechanic support structure during operations. DFSS data was obtained for over 500 C-2W shots and will continue until the expiration of this CRADA on September 30 th 2023. Over the course of this work, significant progress was made to maximize the signal to noise (SNR) ratio. Analysis of recently acquired data is on-going, however, initial indications are highly suggestive that a DFSS signal above background has been successfully acquired in C-2W.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Hybrid time–frequency domain dual-probe coherent anti-Stokes Raman scattering for simultaneous temperature and pressure measurements in compressible flows via spectral fitting

We demonstrate a hybrid time–frequency spectroscopic method for simultaneous temperature/pressure measurements in nonreacting compressible flows with known gas composition. Hybrid femtosecond–picosecond, pure-rotational coherent anti-Stokes Raman scattering (CARS), with two independent, time-delayed probe pulses, is deployed for single-laser-shot measurements of temperature and pressure profiles along an ∼ <#comment/> 5 -mm line. The theory of dual-probe CARS is presented, along with a discussion of the iterative fitting of experimental spectra. Temperature is obtained from spectra acquired with an early, near-collision-free probe time delay ( τ <#comment/> 1 = 0 p s ) and pressure from spectra obtained at probe delays of τ <#comment/> 2 = 150 − <#comment/> 1000 p s , where collisions significantly impact the spectral profile. Unique solutions for temperature and pressure are obtained by iteratively fitting the two spectra to account for small collisional effects observed for the near zero probe delay spectrum. A dual-probe pure-rotational CARS system, in a 1D line-imaging configuration, is developed to demonstrate effectively the simultaneous temperature and pressure profiles recorded along the axial centerline of a highly underexpanded jet. The underexpanded air jet permits evaluation of this hybrid time–frequency domain approach for temperature and pressure measurements across a wide range of low-temperature–low-pressure conditions of interest in supersonic ground-test facilities. Single-laser-shot measurement precisions in both quantities and pressure measurement accuracy are systematically evaluated in the quiet zone upstream of the Mach disk. Precise thermometry approaching 1%−2% is observed in regions of high CARS signal-to-noise ratios. Pressure measurements are optimized at probe time delays where the ratio of the late probe delay to the Raman lifetime exceeds four ( τ <#comment/> 2 / τ <#comment/> R > <#comment/> 4 ). The impact of low-temperature Raman linewidths on CARS pressure measurements is evaluated, and comparisons of CARS pressures obtained with our recent low-temperature pure-rotational Raman linewidth data and extrapolated high-temperature Q -branch linewidths are presented. Considering all measurements with τ <#comment/> 2 / τ <#comment/> R ≥ <#comment/> 4.0 , measured pressures were on average 7.9% of the computed isentropic values with average shot-to-shot deviations representing a combination of instrument noise and fluid fluctuations of 5.0%.

Retter, Jonathan E.↗

Design and Fabrication of Quantum Information Processing Devices (Final Report)

The goal of this work is to develop a wideband Josephson Parametric Amplifier (JPA) by the combination of a coplanar impedance transformer and a lumped Josephson Parametric Amplifier. Josephson Parametric Amplifiers take advantage of the nonlinear inductance of Josephson junctions and the nearly lossless superconductor circuits to achieve wave mixing and amplification with only quantum-limited added noise, which makes it a key component in quantum measurements, such as single-shot qubit measurement. However, the current JPAs generally have a relatively high quality factor and small bandwidth (around 50MHz to 100MHz), which limits their ability in measuring signals from a broad spectrum. Therefore, the work planned to use a coplanar impedance transformer to enhance the coupling between JPA and the signals, resulting in a small quality factor and large bandwidth. By decreasing the quality factor of JPA to around 3, one can achieve around 20dB gain within a bandwidth of several hundred MHz. Moreover, the wideband feature allows this device to explore the frequency dependence of the coupling between the JPA and the signals. Because the impedance transformer is based on a coplanar transmission line and requires no modifications of the lumped JPA, it is relatively straightforward to embed it in the current fabrication, package, and testing process for lumped JPA. The impedance transformer can be fabricated by liftoff or etching process with the lumped JPA together, which adds no fabrication complexity. The only difference is the size, which is around 3~5 times larger than lumped JPA. This may make the number of available chips on a single wafer lower. As for the public benefits, the development of this wideband JPA will make it possible to use just a single JPA device for multi-frequency signals, for example, the readout signals of a superconducting qubit chip with multiplexed readout bus. This would greatly decrease the demand for JPAs in quantum measurements.

42 ENGINEERING↗

A New Window into the Baryon Cycle at Cosmic Noon with Line Intensity Mapping: Forecasts for auto- and cross-correlations in [CII]-158$μ$m, HI 21 cm, CO$_{J+1\rightarrow J}$, and H$α$ galaxies

Across the peak of cosmic star formation at $z\sim1-2$, inflow, processing, and feedback drive rapid changes in the spatial distribution and chemical composition of baryons in galaxies and surrounding reservoirs; this baryon cycle can be tomographically mapped by line intensity mapping (LIM) of atomic hydrogen, ionized carbon, and carbon monoxide. We present a simulation-based forecasting framework for detecting auto- and cross-power spectra between spectroscopic surveys of four such tracers at $z\sim0.5-1.7$ mapping the same deep field - TIM, EoRSpec/FYST, MeerKAT, & Euclid. We forward-model 3-D distributions for these tracers from magnetohydrodynamic simulations, directly capturing the two-halo, one-halo, and shot statistics without relying on analytical decompositions. We further detail a signal-to-noise formalism, tailored to LIM surveys with highly anisotropic geometries and Fourier-space coverage. We demonstrate that galaxy cross-correlations will be the dominant discovery channel for current-generation surveys. These instruments will detect the auto-spectra for CO and HI 21 cm and the CO $\times$ 21 cm cross-spectrum at modest S/N $\sim 1-10$, while placing upper limits on the [CII]-158$μ$m signals. [CII], CO, and HI LIM will be $\sim3-30\times$ ($0.5-1.5$ dex) more sensitive to cross-correlation with the Euclid survey, however, than their respective auto-correlations, constraining all three models of line emission at high significance (S/N $\sim 10-40$) within this decade. Finally, we formulate a staged instrumental trajectory with planned or reasonable improvements, including the as-proposed SKA-Mid. We forecast advancing the per-$k$-mode sensitivities of each auto-, galaxy-line, and line-line spectrum by several orders of magnitude, enabling new percent- and sub-percent level constraints on cosmology and the redshift evolution of star formation and the baryon cycle.

Agrawal, Shubh [Pennsylvania U., Dept. Math.]↗

Single-Shot Readout and Weak Measurement of a Tin-Vacancy Qubit in Diamond

The negatively charged tin-vacancy center in diamond (SnV − ) is an emerging platform for building the next generation of long-distance quantum networks. This is due to the SnV − ’s favorable optical and spin properties including bright emission, insensitivity to electronic noise, and long spin coherence times at temperatures above 1 K. Here, we demonstrate measurement of a single SnV − electronic spin with a single-shot readout fidelity of 87.4%, which can be further improved to 98.5% by conditioning on multiple readouts. In the process, we develop understanding of the relationship between strain, magnetic field, spin readout, and microwave spin control. We show that high-fidelity readout is compatible with rapid microwave spin control, demonstrating a favorable parameter regime for use of the SnV − center as a high-quality spin-photon interface. Finally, we use weak quantum measurement to study measurement-induced dephasing; this illuminates the fundamental interplay between measurement and decoherence in quantum mechanics, and provides a universal method to characterize the efficiency of color-center spin readout. Taken together, these results overcome an important hurdle in the development of the SnV − -based quantum technologies and, in the process, develop techniques and understanding broadly applicable to the study of solid-state quantum emitters.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Analysis Background & Noise in Stretched Wire Alignment Technique Measurements

The Stretched-Wire Alignment Technique (SWAT) is one method of magnet alignment for linear induction accelerators. The applications of SWAT have been implemented for aligning solenoid magnets on the Scorpius linear induction accelerator which will be sited at the Nevada National Security Site and the Flash X-Ray (FXR) linear induction accelerator at Lawrence Livermore National Laboratory’s Contained Firing Facility. This article describes both systematic (repeatable) and random sources of background and noise as well as practical ways to eliminate or reduce them to acceptable levels. Systematic sources include reflections from wire ends, rapid sag due to ohmic heating of the wire, magnetic materials, and shot rate. Random sources include air currents, vibration of nearby equipment, mechanical stability of test equipment, and the instruments used to measure the wire motion. Mitigations include curve fitting and adaptive noise signal cancellation, and mechanical damping. Finite Element Analysis (FEA) was used to identify and resolve a repeatable wire vibration frequency interfering with the signal resolution. Two stretched wire alignment technique set ups from Sandia National Labs and Lawrence Livermore National Lab have shown background noise sources and ways of mitigating them by either analysis methods or change of mechanical configuration. Conclusions that were drawn included the severe sensitivity of the deflection to even small external interferences of the SWAT wire such that it requires attention to detail in mechanical set up and analysis.

Linear Inductive Accelerator↗

Solving the Hele–Shaw flow using the Harrow–Hassidim–Lloyd algorithm on superconducting devices: A study of efficiency and challenges

The development of quantum processors for practical fluid flow problems is a promising yet distant goal. Recent advances in quantum linear solvers have highlighted their potential for classical fluid dynamics. In this study, we evaluate the Harrow–Hassidim–Lloyd (HHL) quantum linear systems algorithm (QLSA) for solving the idealized Hele–Shaw flow. Our focus is on the accuracy and computational cost of the HHL solver, which we find to be sensitive to the condition number, scaling exponentially with problem size. This emphasizes the need for preconditioning to enhance the practical use of QLSAs in fluid flow applications. Moreover, we perform shots-based simulations on quantum simulators and test the HHL solver on superconducting quantum devices, where noise, large circuit depths, and gate errors limit performance. Error suppression and mitigation techniques improve accuracy, suggesting that such fluid flow problems can benchmark noise mitigation efforts. Finally, our findings provide a foundation for future, more complex application of QLSAs in fluid flow simulations.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Milestone report for MRT 8479: High Yield Xray Imager Preliminary Design Review

The High Yield Xray Imager (HYXI) is a new NIF target diagnostic system currently under development. The goal of HYXI is to provide high-fidelity, high temporal resolution x-ray imaging capability on high yield NIF implosions at 10MJ and above. The HYXI instrument design concept is based on the combination of two technologies that have been successfully utilized at the NIF on previous instruments, electron pulse-dilation and hybrid-CMOS sensor imaging. The combination of these two techniques will give HYXI sufficient data quality to ascertain differences in hot spot formation dynamics between high and low yield implosions. This information will highlight the critical hot spot conditions needed for ignition and burn. The HYXI design leverages the successful operation of the PDIXI x-ray imager at the NIF on multi-MJ yield shots. Also, a new radiation tolerance CMOS imaging array is being developed to eliminate the significant background noise which limits the data quality of PDIXI. The HYXI Preliminary Design Review was completed at the end of Q4 FY23. The HYXI project is a multi-year effort with a phased approach to be bring up system functionality over time in parallel with the development and fabrication effort of the new CMOS imaging array. Initial time integrated NIF data will be collected in Q2 FY25, first time resolved imaging with Daedalus starting in Q2 FY26 and the final performance qualification of the complete HYXI system is scheduled for Q2 FY27.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

High Yield Xray Imager Final Design Review

The High Yield Xray Imager (HYXI) is a new NIF target diagnostic system currently under development. The goal of HYXI is to provide high-fidelity, high temporal resolution x-ray imaging capability on high yield NIF implosions at 10MJ and above. The HYXI instrument design concept is based on the combination of two technologies that have been successfully utilized at the NIF on previous instruments, electron pulse-dilation and hybrid-CMOS sensor imaging. The combination of these two techniques will give HYXI sufficient data quality to ascertain differences in hot spot formation dynamics between high and low yield implosions. This information will highlight the critical hot spot conditions needed for ignition and burn. The HYXI design leverages the successful operation of the PDIXI x-ray imager at the NIF on multi MJ yield shots. A new radiation tolerant CMOS imaging array (HYPERION) is being developed to eliminate the significant background noise which limits the data quality of PDIXI. We successfully placed the contract with Advanced hCMOS Systems (AHS) to develop the HYPERION sensor, which fulfils our criteria to place long lead time item procurements by end of FY24. The HYXI Final Design Review was completed at the end of Q4 FY24 (Sep 24 th and Sep 30 th ). The HYXI project is a multi-year effort with a phased approach to be bring up system functionality over time in parallel with the development and fabrication effort of the HYPERION CMOS imaging array. In Phase 1, time-integrated x-ray images on NIF DT experiments will be collected starting in Q3 FY25. In Phase 2 of the project, time-resolved imaging with HYXI utilizing a spare microchannel plate detector back-end will begin in Q3 FY26. Phase 3 concludes the project with the installation of the HYPERION sensor array and the final performance qualification of the HYXI instrument which is scheduled for Q3 FY27 as discussed in the PDR and MRT report on this project in FY23.

42 ENGINEERING↗