Automation and control of an experimental protonic membrane steam methane reforming system
Not Available
SEARCH · Search NASA
Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.
Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.
Not Available
Not Available
The present invention is a Solid Oxide Fuel Cell Reforming Power System that utilizes adiabatic reforming of reformate within this system. By utilizing adiabatic reforming of reformate within the system the system operates at a significantly higher efficiency than other Solid Oxide Reforming Power Systems that exist in the prior art. This is because energy is not lost while materials are cooled and reheated, instead the device operates at a higher temperature. This allows efficiencies higher than 65%.
A steam energy tip sheet for the Advanced Manufacturing Office (AMO)
The HTTF is an integral test facility, which has been designed to model the behavior of interest for a MHTGR during the Depressurized Conduction Cooldown (DCC) event. It also has the potential to conduct limited explorations into the progression of the Pressurized Conduction Cooldown (PCC) event and phenomena during normal operations. The facility is scaled 1:4 by height and 1:64 by volume. A scaling report has been developed and provides further detail into the scaling analysis for the HTTF. The maximum core power for the facility is approximately 2.2MW. The core region will be of a modular design to allow for both the prismatic block core and the pebble bed core designs to be tested. However, only the prismatic block design is discussed in this report. The HTTF consists of the following systems: A primary system consisting of the reactor pressure vessel (RPV), the circulator, cross over ducts and primary piping. The core internals sit inside the RPV and provide support for the core and core heaters. The purpose of the primary system is to maintain the pressure boundary, remove heat from the core through convection, conduction and radiation, and provide heat to the core through a series of electrical heaters. A secondary system consisting of a steam generator, feed water system and main steam system. The purpose of the secondary system is to remove heat from the primary system during heat up, cool down and normal operations. A reactor cavity simulation system consisting of a cavity tank, gas conditioning system and a series of break valves. Note that the prototypical MHTGR sits inside of a cavity. In the event of a break the helium will blowdown into this cavity. At the HTTF, the cavity is modeled as a separate tank, the reactor cavity simulation tank (RCST) and is connected to the RPV through break valves—hot-leg, cold-leg, upper break, and lower break. A reactor cavity cooling system (RCCS) consisting of a series of water cooled panels and the water supply system for these panels. The HTTF RCCS is not a scaled prototypical RCCS system for the MHTGR. It is provided in the HTTF in order to set the boundary condition for radiation heat transfer from the RPV. Various auxiliary systems including the city water supply system, the electrical power supply and distribution system, the chilled water system and the instrument air system.
Analysis of an integrated energy system producing hydrogen in a high temperature steam electrolysis system via steam provided by a sensible heat thermal energy storage system charged by a high temperature gas reactor. Preliminary results over a continuous discharge cycle and single charging cycle shows minimal reactor impact despite 25% electrical power load change. Hydrogen production is held constant with steam provided by the thermal energy storage system.
Potential thermionic power systems for space or terrestrial applications are described so that the development goals can be clearly identified. The thermionic power systems considered are a space nuclear power system, a fossil-fuel thermionic topping steam power system, a solar thermionic topping steam power system, and advanced systems. Attention is given to a discussion of the current status of technology development in thermionic converters and associated elements in power systems. Future prospects of thermionic power systems are also discussed. It is concluded that thermionic conversion has a great potential for a variety of applications.
An evaluation was made of the potential of a steam Rankine reheat reciprocator engine to operate at high efficiency in a point-focusing distributed receiver solar thermal-electric power system. The scope of the study included the engine system and electric generator; not included was the solar collector/mirror or the steam generator/receiver. A parametric analysis of steam conditions was completed leading to the selection of 973 K 12.1 MPa as the steam temperature/pressure for a conceptual design. A conceptual design was completed for a two cylinder/ opposed engine operating at 1800 rpm directly coupled to a commercially available induction generator. A unique part of the expander design is the use of carbon/graphite piston rings to eliminate the need for using oil as an upper cylinder lubricant. The evaluation included a system weight estimate of 230 kg at the mirror focal point with the condenser mounted separately on the ground. The estimated cost of the overall system is $1932 or $90/kW for the maximum 26 kW output.
The National Aeronautics and Space Administration entered a new age on January 14, 2004 with President Bush s announcement of the creation the Vision for Space Exploration that will take mankind back to the Moon and on beyond to Mars. In January, 2006, after two years of hard, dedicated labor, engineers within NASA and its contractor workforce decided that the J2X rocket, based on the heritage of the Apollo J2 engine, would be the new engine for the NASA Constellation Ares upper stage vehicle. This engine and vehicle combination would provide assured access to the International Space Station to replace that role played by the Space Shuttle and additionally, would serve as the Earth Departure Stage, to push the Crew Excursion Vehicle out of Earth Orbit and head it on a path for rendezvous with the Moon. Test as you fly, fly as you test was chosen to be the guiding philosophy and a pre-requisite for the engine design, development, test and evaluation program. An exhaustive survey of national test facility assets proved the required capability to test the J2X engine at high altitude for long durations did not exist so therefore, a high altitude/near space environment testing capability would have to be developed. After several agency concepts the A3 High Altitude Testing Facility proposal was selected by the J2X engine program on March 2, 2007 and later confirmed by a broad panel of NASA senior leadership in May 2007. This facility is to be built at NASA s John C. Stennis Space Center located near Gulfport, Mississippi. 30 plus years of Space Shuttle Main Engine development and flight certification testing makes Stennis uniquely suited to support the Vision For Space Exploration Return to the Moon. Propellant handling infrastructure, engine assembly facilities, a trained and dedicated workforce and a broad and varied technical support base will all ensure that the A3 facility will be built on time to support the schedule needs of the J2X engine and the ultimate flight of the first Ares I vehicle. The A3 facility will be able to simulate pre-ignition altitude from sea-level to 100,000 feet and maintain it up to 650 seconds. Additionally the facility will be able to accommodate initial ignition, shutdown and then restart test profiles. A3 will produce up to 5000 lbm/sec of superheated steam utilizing a Chemical Steam generation system. Two separate inline steam ejectors will be used to produce a test cell vacuum to simulate the 100,000 ft required altitude. Operational capability will ensure that the facility can start up and shutdown without producing adverse pressure gradients across the J2X nozzle. The facility will have a modern thrust measurement system for accurate determination of engine performance. The latest advances in data acquisition and control will be incorporated to measure performance parameters during hotfire testing. Provisions are being made in the initial design of the new altitude facility to allow for testing of other, larger engines and potential upper stage launch vehicles that might require vacuum start testing of the engines. The new facility at Stennis Space Center will be complete and ready for hotfire operations in late 2010.
This paper describes two Systems Engineering Studies completed at the Idaho National Laboratory (INL) to support development of the High Temperature Stream Electrolysis (HTSE) process. HTSE produces hydrogen from water using nuclear power and was selected by the Department of Energy (DOE) for integration with the Next Generation Nuclear Plant (NGNP). The first study was a reliability, availability and maintainability (RAM) analysis to identify critical areas for technology development based on available information regarding expected component performance. An HTSE process baseline flowsheet at commercial scale was used as a basis. The NGNP project also established a process and capability to perform future RAM analyses. The analysis identified which components had the greatest impact on HTSE process availability and indicated that the HTSE process could achieve over 90% availability. The second study developed a series of life-cycle cost estimates for the various scale-ups required to demonstrate the HTSE process. Both studies were useful in identifying near- and long-term efforts necessary for successful HTSE process deployment. The size of demonstrations to support scale-up was refined, which is essential to estimate near- and long-term cost and schedule. The life-cycle funding profile, with high-level allocations, was identified as the program transitions from experiment scale R&D to engineering scale demonstration.
Steam bottoming cycles using adiabatic diesel engine exhaust heat which projected substantial performance and economic benefits for long haul trucks were studied. Steam cycle and system component variables, system cost, size and performance were analyzed. An 811 K/6.90 MPa state of the art reciprocating expander steam system with a monotube boiler and radiator core condenser was selected for preliminary design. The costs of the diesel with bottoming system (TC/B) and a NASA specified turbocompound adiabatic diesel with aftercooling with the same total output were compared, the annual fuel savings less the added maintenance cost was determined to cover the increase initial cost of the TC/B system in a payback period of 2.3 years. Steam bottoming system freeze protection strategies were developed, technological advances required for improved system reliability are considered and the cost and performance of advanced systes are evaluated.
The probability of hazardous step and touch potentials is an important consideration in central station grounding system design. Steam turbine generating station grounding system design is based on accepted industry practices and there is extensive in-service experience with these grounding systems. A photovoltaic (PV) central station is a relatively new concept and there is limited experience with PV station grounding systems. The operation and physical configuration of a PV central station is very different from a steam electric station. A PV station bears some similarity to a substation and the PV station step and touch potentials might be addressed as they are in substation design. However, the PV central station is a generating station and it is appropriate to examine the effect that the differences and similarities of the two types of generating stations have on step and touch potential considerations.
The invention relates to a nuclear plant in which the power of a nuclear reactor is controlled via demand of a connected electric grid. A naturally circulating nuclear reactor coolant loop is linked to a water/steam loop by means of a steam generator. The water/steam loop consists of an electric power generating unit and a water recirculating and steam control system. The generator is coupled to an external power grid. As power requirements of the grid change, a controller linked to the generator and a three way valve divides steam flow between the expansion turbine and a feedwater heater to boost or retard the power output. Altering the steam flow changes the pressure and temperature in the water/steam system and thus the coolant flow rate. The change in coolant flow allows the reactor core to regulate its reactivity to reach a state of equilibrium to the demand for electric power.
A new concept of the Mitsubishi small-sized High temperature gas-cooled modular Reactors (MHR-50/100) had been developed and published in papers. The study results of the first design concept show that the MHR-50/100 can achieve the inherent safety level set as a design target in case of water ingress during steam generator tube rupture accident. And more specifically, the reactor was shown to remain stable during long-term station black out (SBO) with protection of only passive devices during a depressurization accident and with additional motion of steam dump system during a water ingress accident. Recently greater requirements for safety of future nuclear plants including the MHR-50/100 have been expected. This study has thus made a key design improvement for the MHR-50/100 in order to secure the inherent safety aspect without reliance on active steam dump system in case of a water ingress accident. The innovative technologies listed below have been created and investigated to achieve the improved MHR-50/100 design; (1) Design improvement of steam generator, (2) Heat balance optimization of steam cycle, (3) Control system design of differential pressure between primary helium gas and water/steam, (4) Study on operation procedure during a water ingress accident. (authors)
A systematic investigation was conducted on the oxidation behavior of silicon-bond coats within environmental barrier coating (EBC) systems applied to Si-carbide (SiC) substrates, aiming to understand how different underlying SiC substrates influence the bond coat's thermally grown oxide (TGO) and its properties. The study examined (Y/Yb) 2 Si 2 O 7 /Si coatings on three cost-effective surrogate SiC substrates (chemical vapor deposition [CVD]-grown β-SiC, sintered α-SiC, and reaction-bonded [RB] SiC) for SiC fiber /SiC matrix ceramic matrix composites (CMCs). Discrepancies in TGO growth were observed, with noticeably higher growth rates reported for the coated CMC specimens than for the four monolithic SiC specimens. The CMC samples produce an amorphous TGO, whereas the other monolithic substrates formed a crystalline TGO, which lowered the oxygen permeability through the SiO 2 scale. In conclusion, the vitrification of the TGO in the (Y/Yb) 2 Si 2 O 7 /Si/CMC system resulted from the migration of boron species from the CMC substrate to the SiO 2 scale, leading to network modification via boron doping.
The computer-based boiler performance system presented in this article has been developed to provide a direct and quantitative assessment of furnace and convective surface cleanliness. Temperature, pressure, and flow measurements and gas analysis data are used to perform heat transfer analysis in the boiler furnace and evaporator. Power boiler efficiency is calculated using an indirect method. The on-line calculation of the exit flue gas temperature in a combustion chamber allows for an on-line heat flow rate determination, which is transferred to the boiler evaporator. Based on the energy balance for the boiler evaporator, the superheated steam mass flow rate is calculated taking into the account water flow rate in attemperators. Comparing the calculated and the measured superheated steam mass flow rate, the effectiveness of the combustion chamber water walls is determined in an on-line mode. Soot-blower sequencing can be optimized based on actual cleaning requirements rather than on fixed time cycles contributing to lowering of the medium usage in soot blowers and increasing of the water-wall lifetime.
The APR1400 is a pressurized water reactor (PWR). The APR1400 nuclear steam supply system consists of a reactor pressure vessel (RPV), which contains the reactor core, and two primary reactor coolant system loops connected in parallel to the RPV. Each coolant loop consists of a hot leg (HL), a u-tube steam generator (SG), two reactor coolant pumps (RCPs) and two cold legs (CLs). A pressurizer is connected to the hot leg on one of the coolant loops. During normal operation, the RCPs circulate high pressure water through the reactor core to remove the heat. The heated water exits the RPV and passes through the hot legs into the steam generator tubes. Heat is transferred through the walls of the steam generator tubes into a lower pressure secondary coolant system. Cooled primary system water from the steam generators is returned through the RCPs and cold legs to the RPV. The RCPs operate at constant speed; the primary coolant system is designed to provide a prescribed rate of coolant flow through the reactor core. The APR1400 SG secondary coolant system pressure is controlled through modulation of valves in the steam lines to maintain a prescribed turbine inlet pressure. The SG secondary coolant inventory is controlled by using a feedwater control system to maintain a prescribed liquid level in the steam generator downcomer. This water inventory level is sufficient to cover the outer surfaces of the steam generator tubes while preventing overfill that would cause liquid to pass from the steam generators through the steam lines into the turbine system. In the current work, the Nuclear Regulatory Commission's reactor systems analysis code, TRACE?2 was used to perform an analysis of a loss of flow anticipated operational occurrence (AOO). The loss of flow is initiated by a loss of off-site power (LOOP), resulting in a trip of the RCPs. The regulatory purpose of the current work is to confirm safety analyses documented in the APR1400 Design Control Document (DCD)
The use of High Temperature Electrolysis (HTE) for the efficient production of hydrogen without the greenhouse gas emissions associated with conventional fossil-fuel hydrogen production techniques has been under investigation at the Idaho National Engineering Laboratory (INL) for the last several years. The activities at the INL have included the development, testing and analysis of large numbers of solid oxide electrolysis cells, and the analyses of potential plant designs for large scale production of hydrogen using a high-temperature gas-cooled reactor (HTGR) to provide the process heat and electricity to drive the electrolysis process. The results of this research led to the selection in 2009 of HTE as the preferred concept in the U.S. Department of Energy (DOE) hydrogen technology down-selection process. However, the down-selection process, along with continued technical assessments at the INL, has resulted in a number of proposed modifications and refinements to improve the original INL reference HTE design. These modifications include changes in plant configuration, operating conditions and individual component designs. This report describes the resulting new INL reference design coupled to two alternative HTGR power conversion systems, a Steam Rankine Cycle and a Combined Cycle (a Helium Brayton Cycle with a Steam Rankine Bottoming Cycle). Results of system analyses performed to optimize the design and to determine required plant performance and operating conditions when coupled to the two different power cycles are also presented. A 600 MWt high temperature gas reactor coupled with a Rankine steam power cycle at a thermal efficiency of 44.4% can produce 1.85 kg/s of hydrogen and 14.6 kg/s of oxygen. The same capacity reactor coupled with a combined cycle at a thermal efficiency of 42.5% can produce 1.78 kg/s of hydrogen and 14.0 kg/s of oxygen.