Search NASA⌕ Search

SEARCH · Search NASA

Results for “Sim”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 163 records · Page 9

Analysis of Interstitial Elements in Niobium with Secondary Ion Mass Spectrometry (SIMS)

Superconducting Radio Frequency (SRF) cavities provide enhanced efficiency and reduced energy utilization in present day particle accelerators. Niobium (Nb) is the material of choice for these cavities due to its high critical temperature and critical magnetic field. In order to understand why certain treatments, especially a low temperature bake, improve performance, it is important to study Nb surface characteristics and identify elemental contamination that can affect the performance of the cavity. H, C, O, and N are of interest because they are interstitial impurities in Nb. In earlier work, SIMS analysis using a CAMECA IMS-6F with Cs{sup +} primary beam showed that C and N were probably not significant factors impacting performance but there was a very high level of H in the Nb. Ion implants of C, N, O, and D into Nb provided quantification of C, N, O and indicated that D is very mobile in the Nb. Further analyses showed that heat treated Nb has lower levels of surface H than non heat treated Nb and subsequent removal of surface oxide by etching causes intake of H in a heat treated Nb sample. This result helps confirm the role of surface oxide as a hydrogen barrier. To further understand the oxide, Nb samples were anodized to obtain a thicker surface oxide and H and D were implanted into this oxide to check for the appearance of implant peaks. SIMS depth profile analyses were carried out and confirmed the presence of the implant shape for these elements in the oxide. Relative Sensitivity Factor (RSFs) could then be calculated for quantification of H in the oxide. Since the Nb matrix signal showed little change from the oxide to the substrate, the same RSF was used to estimate the H concentration in the Nb at 2x10{sup 22} atoms/cm{sup 3}(approximately 40% mole fraction H).

36 MATERIALS SCIENCE↗

SIM-RIBRAS: A Monte-Carlo simulation package for RIBRAS system

SIM-RIBRAS is a Root-based Monte-Carlo simulation tool designed to help RIBRAS users on experience planning and experimental setup enhancing and caracterization. It is divided into two main programs: CineRIBRAS, aiming beam kinematics, and SolFocus, aiming beam optics. SIM-RIBRAS replaces other methods and programs used in the past, providing more complete and accurate results and requiring much less manual labour. Moreover, the user can easily make modifications in the codes, adequating it for specific requirements of an experiment.

43 PARTICLE ACCELERATORS↗

Low-energy Scattering and Effective Interactions of Two Baryons at $m_{\pi}\sim$ 450 MeV from Lattice Quantum Chromodynamics

The interactions between two octet baryons are studied at low energies using lattice QCD (LQCD) with larger-than-physical quark masses corresponding to a pion mass of $m_{\pi}\sim 450$ MeV and a kaon mass of $m_{K}\sim 596$ MeV. The two-baryon systems that are analyzed range from strangeness $S=0$ to $S=-4$ and include the spin-singlet and triplet $NN$, $\Sigma N$ ($I=3/2$), and $\Xi\Xi$ states, the spin-singlet $\Sigma\Sigma$ ($I=2$) and $\Xi\Sigma$ ($I=3/2$) states, and the spin-triplet $\Xi N$ ($I=0$) state. The $s$-wave scattering phase shifts, low-energy scattering parameters, and binding energies when applicable, are extracted using L\"uscher's formalism. While the results are consistent with most of the systems being bound at this pion mass, the interactions in the spin-triplet $\Sigma N$ and $\Xi\Xi$ channels are found to be repulsive and do not support bound states. Using results from previous studies at a larger pion mass, an extrapolation of the binding energies to the physical point is performed and is compared with experimental values and phenomenological predictions. The low-energy coefficients in pionless EFT relevant for two-baryon interactions, including those responsible for $SU(3)$ flavor-symmetry breaking, are constrained. The $SU(3)$ symmetry is observed to hold approximately at the chosen values of the quark masses, as well as the $SU(6)$ spin-flavor symmetry, predicted at large $N_c$. A remnant of an accidental $SU(16)$ symmetry found previously at a larger pion mass is further observed. The $SU(6)$-symmetric EFT constrained by these LQCD calculations is used to make predictions for two-baryon systems for which the low-energy scattering parameters could not be determined with LQCD directly in this study, and to constrain the coefficients of all leading $SU(3)$ flavor-symmetric interactions, demonstrating the predictive power of two-baryon EFTs matched to LQCD.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

BTE-Sim: Fast Simulation Environment For Public Transportation

The public commute is essential to all urban centers and is an efficient and environment-friendly way to travel. Transit systems must become more accessible and user-friendly. Since public transit is majorly designed statically, with very few improvements coming over time, it can get stagnated, unable to update itself with changing population trends. To better understand transportation demands and make them more usable, efficient, and demographic-focused, we propose a fast, multi-layered transit simulation that primarily focuses on public transit simulation (BTE-Sim). BTE-Sim is designed based on the population demand, existing traffic conditions, and the road networks that exist in a region. The system is versatile, with the ability to run different configurations of the existing transit routes, or inculcate any new changes that may seem necessary, or even in extreme cases, new transit network design as well. In all situations, it can compare multiple transit networks and provide evaluation metrics for them. It provides detailed data on each transit vehicle, the trips it performs, its on-time performance and other necessary factors. Its highlighting feature is the considerably low computation time it requires to perform all these tasks and provide consistently reliable results.

Sen, Rishav↗

Implementing Nonlinear Buoyancy and Excitation Forces in the WEC-Sim Wave Energy Converter Modeling Tool: Preprint

Wave energy converters (WECs) are commonly designed and analyzed using numerical models that combine multi-body dynamics with hydrodynamic models based on the Cummins Equation and linearized hydrodynamic coefficients. These modeling methods are attractive design tools because they are computationally inexpensive and do not require the use of high performance computing resources necessitated by high-fidelity methods, such as Navier Stokes computational fluid dynamics. Modeling hydrodynamics using linear coefficients assumes that the device undergoes small motions and that the wetted surface area of the devices is approximately constant. WEC devices, however, are typically designed to undergo large motions in order to maximize power extraction, calling into question the validity of assuming that linear hydrodynamic models accurately capture the relevant fluid-structure interactions. In this paper, we study how calculating buoyancy and Froude-Krylov forces from the instantaneous position of a WEC device (referred to as instantaneous buoyancy and Froude-Krylov forces from herein) changes WEC simulation results compared to simulations that use linear hydrodynamic coefficients. First, we describe the WEC-Sim tool used to perform simulations and how the ability to model instantaneous forces was incorporated into WEC-Sim. We then use a simplified one-body WEC device to validate the model and to demonstrate how accounting for these instantaneously calculated forces affects the accuracy of simulation results, such as device motions, hydrodynamic forces, and power generation.

13 HYDRO ENERGY↗

SIMS of organics—Advances in 2D and 3D imaging and future outlook

Secondary ion mass spectrometry (SIMS) has become a powerful technique for the label-free analysis of organics from cells to electronic devices. The development of cluster ion sources has revolutionized the field, increasing the sensitivity for organics by two or three orders of magnitude and for large clusters, such as C{sub 60} and argon clusters, allowing depth profiling of organics. The latter has provided the capability to generate stunning three dimensional images with depth resolutions of around 5 nm, simply unavailable by other techniques. Current state-of-the-art allows molecular images with a spatial resolution of around 500 nm to be achieved and future developments are likely to progress into the sub-100 nm regime. This review is intended to bring those with some familiarity with SIMS up-to-date with the latest developments for organics, the fundamental principles that underpin this and define the future progress. State-of-the-art examples are showcased and signposts to more in-depth reviews about specific topics given for the specialist.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Analysis of useful ion yield for the Mg dopant in GaN by quadrupole—SIMS

The authors present a quantitative secondary ion mass spectrometry (SIMS) analysis of the useful ion yield of magnesium dopant in a gallium nitride matrix. A quadrupole SIMS instrument was used to analyze an Mg-doped GaN sample grown by metal organic chemical vapor deposition. Oxygen (O2+) was used as the primary ion beam and its energy was varied in the range from 0.5 to 5 kV with and without oxygen flooding near the sample. The results of the analysis can be used to determine the primary beam energies for optimal magnesium sensitivity.

Senevirathna, M. K. Indika (ORCID:0000000243575029↗

Improved quantitation of SIMS depth profile measurements of niobium via sample holder design improvements and characterization of grain orientation effects

The importance of SIMS analyses for “N-doped” impurity alloyed niobium and other surface-alloyed materials continues to increase. A major hurdle is the uncertainty of instrument calibration due to changes in sample height either from sample surface topography or from the sample holder itself. The CAMECA sample holder design allows for many types of samples to be analyzed. However, a drawback is that the holder faceplate can bend, contributing an uncertainty in the relative sensitivity factor (RSF) used to quantify the SIMS results. Here, we describe an improved sample holder having a reinforced faceplate, which prevents deflection and reduces uncertainty. Simulations show that the new design significantly reduces deflection from 10 μm to 5 nm. Sample measurements show a reduction of RSF uncertainty from this source from 4.1% to 0.95%. Grain orientation has long been suspected to affect RSF measurement as well. A bicrystal implant standard, consisting of randomly oriented and [001] grains, was successively rotated 15° between analyses. It was observed that 20% of the analyses performed on the randomly oriented grain exhibited anomalously high RSF values as well as slow sputter rates. These features were associated with the changing grain normal orientation with respect to the primary Cs + beam. The grain orientation associated with the rise in RSF was simulated and determined to be the [101] crystallographic plane, thus indicating that ion channeling was responsible for the significantly increased RSF. Focused ion beam analysis confirmed slower sputter rates for the cardinal crystallographic orientations, indicating that ion channeling occurred for each.

43 PARTICLE ACCELERATORS↗

In-house synthesized poly(ether ether ketone) ionenes. I. ToF-SIMS spectra in the positive ion mode

Static time-of-flight secondary ion mass spectrometry (ToF-SIMS) was performed for acquiring the high-resolution surface spectra of four types of synthesized imidazolium ionene membranes. These novel membranes have aromatic ether–ketone–ether linkages inspired by poly(ether ether ketone) (PEEK). The PEEK-ionenes synthesized for this study have imidazolium cations placed in the polymeric backbone with bistriflimide [Tf 2 N]- counterions. The attention given to synthetically modified PEEK derivatives, such as PEEK-ionenes, is considerable due to their ability to selectively capture CO 2 molecules and other light gases. Therefore, it is important to characterize the surface of these synthesized novel PEEK-ionenes. In this work, characteristic and unique peaks were identified in the positive spectra of each sample. The differences in mass spectra among the samples provide insights for optimizing or fine-tuning the PEEK-ionenes synthesis to achieve a high-performance CO 2 separation membrane with enhanced permeability, selectivity, and mechanical stability. The SIMS spectra and identified characteristic peaks of these synthesized ionenes will serve as a reference in the positive mode, complementing the corresponding spectra reported in the negative ion mode (Paper II).

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Observation of N-rich solid-electrolyte interphase by ToF-SIMS.

Formation of a stable solid electrolyte interphase (SEI) between lithium electrodes and electrolyte upon multiple charge/discharge cycles is crucial to a long-term lithium-ion battery performance. Addition of LiNO3 to lithium bis (fluorosulfonyl) imide/poly(ethylene oxide) (LiFSI/PEO) electrolyte leads to a durable SEI that is electrically insulating yet highly conductive to Li ions, chemically and electrochemically stable, physically uniform, and mechanically robust. ToF-SIMS was used here in combination with sputtering by a gaseous cluster ion beam (GCIB) to examine how the addition of a small proportion of LiNO3 to the LiFSI/PEO electrolyte affects the SEI composition. Negative ion ToF-SIMS spectra of the cycled samples display an intense m/z 26 peak associated with the SEI. Exact mass assignments and isotopic ratios indicate that this peak should be assigned as (CN-)-C-12, with little to no negative secondary ion signal arising from (LiF-)-Li-7. This CN- signal appears to arise from an N-rich portion of the SEI adjacent to the Li electrode that is depleted in LiF relative to the bulk electrolyte. The dearth of LiF- (and LiF+ from the positive ion spectra) is unexpected because LiF has been identified in the SEI in similar samples. Finally, GCIB sputtering indicates that the SEI adheres more strongly to the Li electrode than to the LiFSI/PEO electrolyte.

Shavandi, Seyedeh Reyhaneh↗

TH-A-BRF-03: Evaluation of Synthetic CTs Generated Using MR-SIM Data

Purpose: To describe and evaluate a novel algorithm for generating synthetic CT images from MR-SIM data for dose calculations in MR-only treatment planning. Methods: A voxel-based weighted summation method was implemented to generate synthetic CT (synCT) images. MR data were acquired using Philips 1.0T Panorama high-field open MR-SIM. Retrospective patient data from seven prostate patients and one brain patient (three lesions) enrolled in an IRB-approved study were used. 3D T1-weighted fast field echo and 3D T2-weighted turbo spin echo sequences were utilized for all patients. A 3D balanced turbo field echo sequence using spectral presaturation with inversion recovery was acquired for prostate patients, but 3D ultra-short echo time (UTE)-DIXON was instead acquired for the brain patient to amplify bone signal for semi-automatic bone segmentation. Weight optimization was performed using a training subset of patients. HU value differences between planning CT and synCTs were analyzed using mean absolute error (MAE). Original patient CT-based treatment plans were mapped onto synCTs, dose was recalculated using original leaf motion and MU values, and DRRs were generated. Dosevolume metrics and gamma analysis were used for dosimetric evaluation. Results: Average whole-body MAE of synCTs across all patients was 75+12 HU. In prostate cancer patients, average HU difference between planning and synCTs was 0.9±1.0% for soft tissue structures and 4.3±2.5% for bony structures. DRRs were generated from synCTs and qualitatively showed good geometric agreement with planning CT-generated DRRs. D99, mean dose, and maximum dose to CTV calculated using the synCT remained within 1.2% of planning CT-based dose calculations. All gamma analysis evaluated at 2%/2mm dose difference/distance to agreement) pass rates were greater than 95% with an average of 99.9±0.1% for prostate patients and 98.4±2.2% for three brain lesions. Conclusion: SynCTs were generated with clinically acceptable accuracy comparable to planning CTs, enabling dose computations for MR-only simulation. Research supported in part by a grant from Philips HealthCare (Best, Netherlands)

60 APPLIED LIFE SCIENCES↗

Real-Sim Flexible Interface for X-in-the-loop Simulation (FIXS)

Real-Sim is a multi-resolution X-in-the-loop simulation framework to support inclusive testing and evaluation of CAVs before actual implementation in the real world. Real-Sim framework connects different simulation components and integrates various traffic and vehicle simulation tools, virtual environments, and XIL systems through a Flexible Interface for XIL Simulation (FIXS). Connections among different tools are transparent to users and handled by the interface behind the scenes. Co-simulation of various vehicle and traffic simulation tools with different XIL systems can be easily achieved and become a transparent "plug-and-play" process to users.

Shao, Yunli (0000000185287925)↗

NWQ-sim

NWQSim is a quantum circuit simulation environment developed at PNNL. It currently includes two major components: a state-vector simulator (SV-Sim) and a density matrix simulator (DM-Sim) and we may add more components, such as a Clifford simulator, in the future effort. NWQSim has two language interface: C/C++ and Python. It supports Q#/QDK frontend through QIR and QIR-runtime. It supports Qiskit and Cirq frontends through OpenQASM. NWQSim runs on several backends: Intel-CPU, Intel-Xeon-Phi, AMD-CPU, AMD-GPU, NVIDIA-GPU, and IBM-CPU. It supports three modes: (1) single processor, such as a single CPU (with and without AVX2 and AVX512 acceleration), a single NVIDIA GPU or a single AMD GPU; (2) single-node-multi-processors, such as multi-CPUs/Xeon-Phis, multi-NVIDA/AMD GPUs; (3) multi-nodes, such as a CPU cluster, a Xeon-Phi cluster (e.g., ANL Theta, NERSC Cori), an NVIDIA cluster (e.g., ORNL Summit, NERSC Perlmutter).

Li, Ang↗

First Direct Imaging and Profiling TOF-SIMS Studies on Cutouts from Cavities Prepared by State-of-the-Art Treatments

Small amounts of interstitial impurities in the penetra-tion depth of superconducting radio frequency (SRF) cavities have a dramatic effect on the quality factors and maximum accelerating gradients. Here we report the first TOF-SIMS studies of cutouts from cavities prepared by all modern surface treatments, which allow a direct corre-lation of the impurity distribution with the observed cavity performance. Imaging capability of our instrument allows to avoid the possible issues associated with the ‘‘ghost’’ depth profiles appearing as a consequence of particulate surface contamination, which likely caused the inconclusive SIMS results on e.g. oxygen diffusion in the past.

43 PARTICLE ACCELERATORS↗

SIMS CHARACTERIZATION OF NITROGEN DOPING OF LCLS-II-HE PRODUCTION CAVITIES

The thermal diffusion of nitrogen into the surface of niobium has been shown to yield superior low-loss SRF performance. An effective solution was identified and promptly employed in the production of cryomodules for LCLS-II. With added experience and R&D, a modified process was chosen for use in the upgrade for LCLS-II-HE. Largely motivated by this circumstance, supporting research has significantly refined the technique for making calibrated secondary ion mass spectrometry (SIMS) measurements of the N concentration depth profiles produced by production processes. Standardized reference samples were included with four HE production cavities in their N-doping furnace runs. We report the calibrated dynamic SIMS depth profiles of N, C, and O for these samples, together with the cryogenic acceptance test performance of the associated cavities. Interpretation and comparison with similar samples acquired in other furnaces highlights the importance of intentional process quality control of furnace conditions.

Reece, Charles↗

xLPR Sim Editor 1.0 User's Guide

The United States Nuclear Regulatory Commission in cooperation with the Electric Power Research Institute contracted Sandia National Laboratories to develop the framework of a probabilistic fracture mechanics assessment code called xLPR ( Extremely Low Probability of Rupture) Version 2.0 . The purpose of xLPR is to evaluate degradation mechanisms in piping systems at nuclear power plants and to predict the probability of rupture. This report is a user's guide for xLPR Sim Editor 1.0 , a graphical user interface for creating and editing the xLPR Version 2.0 input file and for creating, editing, and using the xLPR Version 2.0 database files . The xLPR Sim Editor, provides a user - friendly way for users to change simulation options and input values, s elect input datasets from xLPR data bases, identify inputs needed for a simulation, and create and modify an input file for xLPR.

97 MATHEMATICS AND COMPUTING↗

Hanford Soil Inventory Model (SIM-v2) Calculated Radionuclide Inventory of Direct Liquid Discharges to Soil in the Hanford Site's 200 Areas

The Hanford soil inventory model (SIM) provides the basic radionuclide and chemical soil inventories from historical liquid discharges to about 400 sites at the Hanford Site. Although liquid discharge inventory for chemicals is part of the SIM implementation, only radionuclide inventory is discussed here since the focus of this ECF is on providing radionuclides inputs for the composite analysis (CA) per DOE Order 435.1, Radioactive Waste Management, requirements. Furthermore, discharged inventories are only estimated for the soluble portions of the liquid discharges to waste sites/waste management areas located on the 200 Area of the Hanford Site (Central Plateau).

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

SIMS CHARACTERIZATION OF NITROGEN DOPING OF LCLS-II-HE PRODUCTION CAVITIES

The thermal diffusion of nitrogen into the surface of niobium has been shown to yield superior low-loss SRF performance. An effective solution was identified and promptly employed in the production of cryomodules for LCLS-II. With added experience and R&D, a modified process was chosen for use in the upgrade for LCLS-II-HE. Largely motivated by this circumstance, supporting research has significantly refined the technique for making calibrated secondary ion mass spectrometry (SIMS) measurements of the N concentration depth profiles produced by production processes. Standardized reference samples were included with four HE production cavities in their N-doping furnace runs. We report the calibrated dynamic SIMS depth profiles of N, C, and O for these samples, together with the cryogenic acceptance test performance of the associated cavities. Interpretation and comparison with similar samples acquired in other furnaces highlights the importance of intentional process quality control of furnace conditions.

Reece, Charles↗