Search NASA⌕ Search

SEARCH · Search NASA

Results for “Technology Performance Exchange”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 163 records · Page 9

Nanochannel electrodes facilitating interfacial transport for PEM water electrolysis

Proton-exchange membrane water electrolyzers (PEMWEs) are a promising technology for green hydrogen production; however, interfacial transport behaviors are poorly understood, hindering device performance and longevity. Here, we first utilized finite-gap electrolyzer to demonstrate the possibility of proton transfer through water in PEMWEs. The measured high-frequency resistances (HFRs) exhibit a linear trend with increasing gap distance, where extrapolation shows a lower value compared with HFRs in regular zero-gap electrolyzers, indicating that ohmic resistance could be further reduced. We introduce nanochannels to facilitate mass transport, as evidenced by both liquid-fed and vapor-fed electrolysis. Nanochannel electrodes achieve a voltage reduction of 190 mV at 9 A·cm –2 compared with the Ir-PTEs without nanochannels. Furthermore, nanochannel electrodes show negligible degradation through 100,000 accelerated-stress tests and over 2,000 h of operation at 1.8 A·cm –2 with a decay rate of 11.66 μV·h –1 . These results provide new insights into localized transport dynamics for PEMWEs and highlight the significance of interfacial engineering for electrochemical devices.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Sensitivity Analysis of Particle-In-Cell Modeling Parameters in Settling Bed, Bubbling Fluidized Bed and Circulating Fluidized Bed

The objective of the work presented is to perform a preliminary sensitivity analysis of particle-in-cell (PIC) model parameters when applied to settling bed, bubbling fluidized bed, and circulating fluidized bed simulations. These examples correspond to widely different flow conditions commonly seen in chemical engineering applications. Simulations were performed using the PIC method in the open-source software Multiphase Flow with Interphase eXchanges (MFiX) developed by the National Energy Technology Laboratory (NETL). As part of the non-intrusive uncertainty quantification (UQ) analysis, simulation campaigns were generated using Nodeworks. Sampling locations or settings for PIC model parameters were determined using the Latin Hypercube method. Response surfaces were created using radial basis functions (RBF), and Sobol’ indices were estimated to quantify the influence of model parameters on the quantities of interest (QoI). This study marks a first step towards systematically determining optimal ranges for model parameters used in MFiX-PIC. Based on limited experience, it is expected that these values would depend strongly on flow conditions. Given the complexity of the multiphase flow systems under analysis, a non-intrusive UQ based approach is used to identify the most influential parameters in each case. This prior knowledge will help in proposing an effective design of experiments (DoE) and determine optimal parameters through techniques such as deterministic or Bayesian calibration, which will be pursued in the future.

42 ENGINEERING↗

Modeling a Gas-Cooled Microreactor Balance of Plant for the Virtual Test Bed

High Temperature Gas-cooled Reactors (HTGRs) are one of the technology considered for microreactor designs because of their high performance and technological maturity. Several designs are being developed. These microreactor cores are connected to power conversion system (PCS) through a heat exchanger. For transient analysis, the feedback of the PCS or of the primary loop can be important, therefore, it is necessary to develop robust models for the balance of plant that can be coupled to a core model. In this work, a balance of plant model using the MOOSE Thermal Hydraulics module (THM) is presented and demonstrated for startup and load-follow transients. This model can be seamlessly coupled with any MOOSE-based multi-physics core model using the MOOSE multi-app approach.

22 GENERAL STUDIES OF NUCLEAR REACTORS↗

THERMAL PERFORMANCE ANALYSIS FOR SMALL ION-EXCHANGE CESIUM REMOVAL PROCESS

The In-Riser Ion Exchange program focuses on the development of in-tank systems to decontaminate high level waste (HLW) salt solutions at the Savannah River Site (SRS) and the Hanford Site. Small Column Ion Exchange (SCIX) treatment for cesium removal is a primary in-riser technology for decontamination prior to final waste immobilization in Saltstone. Through this process, radioactive cesium from the salt solution is adsorbed onto the ion exchange media which is packed within a flow-through column. Spherical Resorcinol-Formaldehyde (RF) is being considered as the ion exchange media for the application of this technology at both sites. A packed column loaded with media containing radioactive cesium generates significant heat from radiolytic decay. Under normal operating conditions, process fluid flow through the column can provide adequate heat removal from the columns. However, in the unexpected event of loss of fluid flow or fluid drainage from the column, the design must be adequate to handle the thermal load to avoid unacceptable temperature excursions. Otherwise, hot spots may develop locally which could degrade the performance of the ion-exchange media or the temperature could rise above column safety limits. Data exists which indicates that performance degradation with regard to cesium removal occurs with RF at 65C. In addition, the waste supernate solution will boil around 130C. As a result, two temperature limits have been assumed for this analysis. An additional upset scenario was considered involving the loss of the supernate solution due to inadvertent fluid drainage through the column boundary. In this case, the column containing the loaded media could be completely dry. This event is expected to result in high temperatures that could damage the column or cause the RF sorbent material to undergo undesired physical changes. One objective of these calculations is to determine the range of temperatures that should be evaluated during testing with the RF media. Although, the safety temperature limit is based on the salt solution boiling point which does not apply in the air-filled case (because there is no liquid), this same limit (130C) is used as a measure for the evaluation of this condition as well. The primary objective of the present work is to develop models to simulate the thermal performance of the RF column design when the media is fully loaded with radioactive cesium and the central cooling tube is excluded. Previous analysis led to the consideration of this design simplification for RF, since the baseline column design with center cooling was developed assuming that CST media would be used for cesium removal which has a higher volumetric heat load. Temperature distributions and maximum temperatures across the column during SCIX process operations and upset conditions were conducted with a focus on SCIX implementation at Hanford. However, a feed composition and cesium loading were assumed which were known to be considerably higher than would typically be observed at Hanford. In order to evaluate the impact of this potentially highly conservative assumption, fractionally-reduced loading cases were also considered. A computational modeling approach was taken to include conservative, bounding estimates for key parameters so that the results would provide the maximum temperatures achievable under the design configurations.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Sensitivity and Effective Parameterization of a Multi-Scale Model of Proton-Exchange-Membrane Water Electrolysis

The development of proton-exchange-membrane water electrolysis (PEMWE) is crucial to establishing a green-hydrogen infrastructure. Active research in hydrogen technologies is focused on minimizing costs, improving efficiency, and mitigating safety risks. In this study, sensitivity analyses were performed using a physics-based model and used to identify critical parameters capable of reducing overpotentials and safety risks. These parameters include operational (i.e. temperature), structural (i.e. thickness of the components), and material properties (i.e. exchange current density). Simulated results suggest that better engineering of the membrane electrode assemblies (MEA) can offset intrinsic limitations. Membrane thickness and conductivity yielded the largest percent change on performance. Gas crossover was observed to be sensitive to diffusion, solubility, and bubble formation. Current density regimes were identified, where each crossover parameter was most influential. MEA parameterization serves as a framework for theoretical PEMWE optimization simulations and input for design criteria for future research targets.

Dizon, A↗

RESORCINOL-FORMALDEHYDE ION EXCHANGE RESIN CHEMISTRY FOR HIGH LEVEL WASTE TREATMENT

A principal goal at the Savannah River Site is to safely dispose of the large volume of liquid nuclear waste held in many storage tanks. In-tank ion exchange technology is being considered for cesium removal using a polymer resin made of resorcinol formaldehyde that has been engineered into microspheres. The waste under study is generally lower in potassium and organic components than Hanford waste; therefore, the resin performance was evaluated with actual dissolved salt waste. The ion exchange performance and resin chemistry results are discussed.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

High Power Density, Carbon Neutral Electrical Power Generation for Air Vehicles

The synergistic integration of a Solid Oxide Fuel Cell-Combustor (SOFC-C) with a turbogenerator (TG) will provide a very high fuel-to-electricity conversion efficiency while maintaining high power-to-weight ratio during high-altitude flight. The proposed SOFC-C-TG power generation technology exceeds the REEACH technical performance targets (TPT). This unique concept addresses many of the challenges faced in all electric propulsion-based aviation. The system has high part-load efficiency (more than 65% lower heating value (LHV)) during long cruise times, load following capability, high-power capacity at high altitudes adapting to low temperatures and pressures, rapid startup time of less than 30 minutes (proven with current SOFC technology), high power density (more than 3.2 kW/kg), efficient thermal management, and a foundation for a compact, efficient electrical storage and power generation system (ESPG). The SOFC-C concept achieves the technology targets by reducing the complexity of traditional fuel cell-gas turbine hybrid systems (FC-GT). The SOFC-C does not require heat exchangers and dramatically reduces the balance of plant increasing power density and performance in efficiency. The reduction in mass through elimination of heat exchangers, external reformer, and other components dramatically decreases the overall thermal dampening of the system which enables rapid startup and load following capability. Direct control of the cathode inlet temperature of the SOFC-C enables rapid warm-up of the SOFC tubes with the ability to reach operating temperature and full power in less than 30 minutes.

03 NATURAL GAS↗

Validated model of a thermoelectric heat pump clothes dryer using secondary pumped loops

The energy associated with clothes drying makes up 4% of the total residential electrical energy consumption in the US. The cost is high since most clothes dryers use electric resistance heating which is inexpensive but also energy inefficient. State-of-the-art vapor-compression heat pump clothes dryers offer significant energy savings but have limited market penetration in the US. Here, a new configuration of clothes dryer was studied that utilizes a solid-state thermoelectric heat pump with pumped secondary water loops and conventional fin-and-tube water-to-air heat exchangers. Experimental results are presented for the thermoelectric dryer prototype with a combined energy factor of 6.89 lb BDW /kWh (specific moisture extraction rate of 1.71 kg w /kWh) and a dry time of 84 min for a standard load size of 8.45 lb (3.83 kg) with 57.5% starting moisture content. This is a 85% energy efficiency improvement over baseline electric resistance dryers. The efficiency and drying time results achieved are similar to vapor compression heat pump dryers. Compared to previous air-based thermoelectric clothes dryers, the energy efficiency has been increased by 6%, but drying time has been reduced by as much as 47% using secondary pumped loops and separate heat exchangers, which represents a significant advancement in the technology. In addition to the experimental prototype, a model was also developed to study the performance. The model was validated against experimental prototype data and used to identify the range of performance (dry time and efficiency) that could be expected of the design.

42 ENGINEERING↗

Electro-Osmosis and Water Uptake in Polymer Electrolytes in Equilibrium with Water Vapor at Low Temperatures

Water uptake and electro-osmosis are investigated to improve the understanding and aid the modeling of water transport in proton-exchange membrane fuel cells (PEMFCs) below 0 C. Measurements of water sorption isotherms show a significant reduction in the water capacity of polymer electrolytes below 0 C. This reduced water content is attributed to the lower vapor pressure of ice compared to supercooled liquid water. At -25 C, 1100 equivalent weight Nafion in equilibrium with vapor over ice has 8 moles of water per sulfonic acid group. Measurements of the electro-osmotic drag coefficient for Nafion and both random and multiblock copolymer sulfonated poly(arylene ether sulfone) (BPSH) chemistries are reported for vapor equilibrated samples below 0 C. The electro-osmotic drag coefficient of BPSH chemistries is found to be {approx}0.4, and that of Nafion is {approx}1. No significant temperature effect on the drag coefficient is found. The implication of an electro-osmotic drag coefficient less than unity is discussed in terms of proton conduction mechanisms. Simulations of the ohmically limited current below 0 C show that a reduced water uptake below 0 C results in a significant decrease in PEMFC performance.

25 ENERGY STORAGE↗

Advanced supercritical carbon dioxide cycles

The supercritical carbon dioxide cycle (sCO2) has been chosen as the most promising cycle to meet the SunShot goals with a power block that has the potential to achieve thermal efficiencies of 50+% with a turbine inlet temperature of 720 o C. While this cycle has significant potential, it is a fairly new cycle and therefore the costs and performance of the cycle are not known to the level required for detailed economic analysis. There are also multiple cycle configurations that may be used and the choice of configuration could depend on size, cost constraints, efficiency, cooling mode, O&M costs, etc. Each of the variants has particular advantages and drawbacks that have to be understood. The most cost effective way to understand these variants is to use models that allow us to predict the performance of the cycles linked to the heat source (solar thermal energy). In order to do this these models, need to be developed and improved to better predict the costs and performance of the cycle. One of the issues identified with the supercritical Brayton cycle is the fact that a large amount of internal heat exchange is required in order for it to realize its efficiency potential. To address this, recuperators of the Printed Circuit Heat Exchanger (PCHE) design have been primarily considered. While PCHEs are fairly advanced technology and have significant potential there are several drawbacks associated with them. The first being their cost; it is estimated that the two recuperators in a recompression Brayton cycle will cost more than 30% of the entire power block. Another major issue is the in service performance and lack of ability to repair or easily clean the recuperators. If there is a defect in a diffusion bond, fouling or plugging of the channels or mechanical damage due to rapid thermal transient then the entire PCHE may need to be replaced. The third issue is the lack of data and information on the performance of PCHEs at the scale that would be required even for a small 10 MWe plant. To date PCHE heat exchangers have not been constructed at this size and it is necessary to have multiple modules headered together in order to be able to recuperate up to the 40 MWth required in even a small, 10 MWe plant.

14 SOLAR ENERGY↗

Heat Integration Optimization and Dynamic Modeling Investigation for Advancing the Coal-Direct Chemical Looping Process

The purpose of the project is to address the optimization and startup operation of a modular coal direct chemical looping (CDCL) combustion system integrated with a steam cycle for power generation to reduce the risks involved in further scale-up of the technology. The modular reactor design of the CDCL process provides flexibility in the fabrication of the reactor and in its operating capacity (i.e. turndown ratio) at the cost of a more complex heat exchange network (HEN) design and integration. To address the technology gaps and advance the efficiency and economic feasibility of the CDCL technology, the project will perform a detailed and comprehensive analysis of the integration of a modular CDCL reactor system and a steam cycle system under both static and transient conditions via HEN process performance simulations and system dynamic modeling, respectively. The scope of work consists of 1) Experimental and computational studies of the CDCL combustor reactor 2) Comprehensive static (i.e. steady-state) system HEN design analysis in CDCL 550 MWe commercial unit for power generation and 3) Dynamic modeling of site specific design of 10MWe CDCL large pilot plant. The project team has successfully developed and validated a kinetic model for the oxidation of oxygen carriers in the combustor using the unreacted shrinking core model (UCSM). The model is capable of capturing the oxidation kinetics of fully or partially reduced oxygen carrier particles. A computational fluid dynamics (CFD) model is developed to simulate the hydrodynamics, heat transfer, and chemical reaction occurring in the CDCL combustor. The model is developed in MFIX and ANSYS Fluent. Key aspects of CDCL combustor operation, including heat transfer, oxygen carrier oxidation, and the transport of oxygen carrier particles, are simulated using this CFD model. The HEN for a commercial scale 550 MWe CDCL power plant is simulated and optimized using ASPEN Plus. Practical design considerations are incorporated based on industrial experiences. The performance and cost for the commercial CDCL plant is updated based on these analyses. A dynamic model for the 10 MWe CDCL pilot plant is developed in ProTRAX simulation software. The model is based on the pilot plant design developed in project DE-FE0027654 “10 MWe CDCL Large Pilot Plang – Pre-FEED Study” and the steam cycle data obtained from Dover Light & Power plant. The transient behaviors during pilot plant load variation are simulated using the dynamic model.

01 COAL, LIGNITE, AND PEAT↗

Automotive Power Electronics Cooling Technology Research at NREL

This presentation describes power electronics thermal management technologies used for on-road EVs. Examples are provided and heat exchangers are described. Advanced cooling technologies developed are NREL to enable increased power density and enable high WBG temperature operation are then presented. The performance (e.g., thermal resistance, pumping power) of the advanced power electronics cooling technologies are compared to the performance of current, on-road technology.

ADVANCED PROPULSION SYSTEMS↗

Power Electronics Cooling Technology Research at NREL

This presentation describes power electronics thermal management technologies used for on-road EVs. Examples are provided and heat exchangers are described. Advanced cooling technologies developed are NREL to enable increased power density and enable high WBG temperature operation are then presented. The performance (e.g., thermal resistance, pumping power) of the advanced power electronics cooling technologies are compared to the performance of current, on-road technology.

DIRECT ENERGY CONVERSION↗

Advanced Alkaline Membrane H 2 /Air Fuel Cell System with Novel Technique for Air CO 2 Removal

Over the course of this project, significant progress was achieved in developing the hydroxide exchange membrane fuel cell (HEMFC) and the electrochemically-driven CO₂ separator (EDCS), with a focus on improving performance, durability, and scalability. Key milestones were met, and the technology demonstrated potential for a wide range of applications, including fuel cell vehicles, direct air capture (DAC), and life support systems.

08 HYDROGEN↗

High-performance ammonia oxidation catalysts for anion-exchange membrane direct ammonia fuel cells

Low-temperature direct ammonia fuel cells (DAFCs) use carbon-neutral ammonia as a fuel, which has attracted increasing attention recently due to ammonia's low source-to-tank energy cost, easy transport and storage, and wide availability. However, current DAFC technologies are greatly limited by the kinetically sluggish ammonia oxidation reaction (AOR) at the anode. Herein, we report an AOR catalyst, in which ternary PtIrZn nanoparticles with an average size of 2.3 ± 0.2 nm were highly dispersed on a binary composite support comprising cerium oxide (CeO 2 ) and zeolitic imidazolate framework-8 (ZIF-8)-derived carbon (PtIrZn/CeO 2 -ZIF-8) through a sonochemical-assisted synthesis method. Additionally, the PtIrZn alloy, with the aid of abundant OH ad provided by CeO 2 and uniform particle dispersibility contributed by porous ZIF-8 carbon (surface area: ~600 m 2 g -1 ), has shown highly efficient catalytic activity for the AOR in alkaline media, superior to that of commercial PtIr/C. The rotating disk electrode (RDE) results indicate a lower onset potential (0.35 vs. 0.43 V), relative to the reversible hydrogen electrode at room temperature, and a decreased activation energy (~36.7 vs. 50.8 kJ mol -1 ) relative to the PtIr/C catalyst. Notably, the PtIrZn/CeO 2 -ZIF-8 catalyst was assembled with a high-performance hydroxide anion-exchange membrane to fabricate an alkaline DAFC, reaching a peak power density of 91 mW cm -2 . Unlike in aqueous electrolytes, supports play a critical role in improving uniform ionomer distribution and mass transport in the anode. PtIrZn nanoparticles on silicon dioxide (SiO 2 ) integrated with carboxyl-functionalized carbon nanotubes (CNT–COOH) were further studied as the anode in a DAFC. A significantly enhanced peak power density of 314 mW cm -2 was achieved. Density functional theory calculations elucidated that Zn atoms in the PtIr alloy can reduce the theoretical limiting potential of *NH 2 dehydrogenation to *NH by ~0.1 V, which can be attributed to a Zn-modulated upshift of the Pt–Ir d-band that facilitates the N–H bond breakage.

25 ENERGY STORAGE↗

Design Option of Heat Exchanger for the Next Generation Nuclear Plant

The Next Generation Nuclear Plant (NGNP), a very High temperature Gas-Cooled Reactor (VHTGRS) concept, will provide the first demonstration of a closed-loop Brayton cycle at a commercial scale of a few hundred megawatts electric and hydrogen production. The power conversion system (PCS) for the NGNP will take advantage of the significantly higher reactor outlet temperatures of the VHTGRS to provide higher efficiencies than can be achieved in the current generation of light water reactors. Besides demonstrating a system design that can be used directly for subsequent commercial deployment, the NGNP will demonstrate key technology elements that can be used in subsequent advanced power conversion systems for other Generation IV reactors. In anticipation of the design, development and procurement of an advanced power conversion system for the NGNP, the system integration of the NGNP and hydrogen plant was initiated to identify the important design and technology options that must be considered in evaluating the performance of the proposed NGNP. As part of the system integration of the VHTGRS and hydrogen production plant, the intermediate heat exchanger is used to transfer the process heat from VHTGRS to hydrogen plant. Therefore, the design and configuration of the intermediate heat exchanger are very important. This paper will include analysis of one stage versus two stage heat exchanger design configurations and thermal stress analyses of a printed circuit heat exchanger, helical coil heat exchanger, and shell/tube heat exchanger.

99 GENERAL AND MISCELLANEOUS↗

Numerical study on the stability of weakly collisional plasma in E×B fields

Plasma stability in weakly collisional plasmas in the presence of E×B fields is studied with numerical simulations. Different types of ion-neutral collisions are considered in a fully magnetized regime. We study the influence of ion-neutral collisions and the role of collision types on the stability of plasma. It is found that the stability of plasma depends on the type of ion-neutral collisions, with the plasma being unstable for charge exchange collisions, and stable for the elastic scattering. The analysis focuses on the temporal evolution of the velocity phase space, RMS values of the potential fluctuations, and coherent structures in potential densities. For the unstable case, we observe growth and propagation of electrostatic waves. Simulations are performed with a three-dimensional electrostatic particle in cell code.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Magnetic coupling at rare earth ferromagnet/transition metal ferromagnet interfaces: A comprehensive study of Gd/Ni

Thin film magnetic heterostructures with competing interfacial coupling and Zeeman energy provide a fertile ground to study phase transition between different equilibrium states as a function of external magnetic field and temperature. A rare-earth (RE)/transition metal (TM) ferromagnetic multilayer is a classic example where the magnetic state is determined by a competition between the Zeeman energy and antiferromagnetic interfacial exchange coupling energy. Technologically, such structures offer the possibility to engineer the macroscopic magnetic response by tuning the microscopic interactions between the layers. We have performed an exhaustive study of nickel/gadolinium as a model system for understanding RE/TM multilayers using the element-specific measurement technique x-ray magnetic circular dichroism, and determined the full magnetic state diagrams as a function of temperature and magnetic layer thickness. We compare our results to a modified Stoner-Wohlfarth-based model and provide evidence of a thickness-dependent transition to a magnetic fan state which is critical in understanding magnetoresistance effects in RE/TM systems. In conclusion, the results provide important insight for spintronics and superconducting spintronics where engineering tunable magnetic inhomogeneity is key for certain applications.

36 MATERIALS SCIENCE↗