Search NASA⌕ Search

SEARCH · Search NASA

Results for “Thermometers”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 163 records · Page 9

Measuring Temperature Reading

There are two requirements for taking a measurement of something. The first is a tool for taking a measurement. The second is scale for making sense of the numbers of the measurement. For example, a ruler is often used to measure short lengths. It is the tool for measurement. On the ruler are one or more number scales with equally spaced numbers. These numbers can be compared with numbers from any other ruler that is accurately set to the same scale. Measuring length is far simpler than measuring temperature. While there is evidence of tools for measuring length at various times in human history, tools and scales for measuring temperature do not appear until more recent human history. Early thermometers, called thermoscopes, first appear in the 1500's. They were crude instruments that were not at all accurate. Most did not even have a number scale associated with them. This made them useless for most practical purposes. Gabriel Fahrenheit created the first accurate thermometer in 1714, and the Fahrenheit temperature scale followed it in 1724. The thermometer s accuracy was based on its use of mercury, a silver colored substance that remains liquid over a wide range of temperatures but expands or contracts in a standard, predictable way with changes in temperature. To set the scale, Fahrenheit created the coldest temperature that he could. He mixed equal parts of ice, water, and salt, and then used this as the zero point, 0 degrees, of his scale. He intended to make 30 degrees the freezing point of water and 90 degrees the temperature of the human body, but he had to later revise these temperatures to be 32 degrees and 96 degrees. In the final version of the scale, the temperature of the human body became 98.6 degrees. 19th century thermoscope

Source record↗

X-Ray Calorimeter Arrays for Astrophysics

High-resolution x-ray spectroscopy is a powerful tool for studying the evolving universe. The grating spectrometers on the XMM and Chandra satellites started a new era in x-ray astronomy, but there remains a need for instrumentation that can provide higher spectral resolution with high throughput in the Fe-K band (around 6 keV) and can enable imaging spectroscopy of extended sources, such as supernova remnants and galaxy clusters. The instrumentation needed is a broad-band imaging spectrometer - basically an x-ray camera that can distinguish tens of thousands of x-ray colors. The potential benefits to astrophysics of using a low-temperature calorimeter to determine the energy of an incident x-ray photon via measurement of a small change in temperature was first articulated by S. H. Moseley over two decades ago. In the time since, technological progress has been steady, though full realization in an orbiting x-ray telescope is still awaited. A low-temperature calorimeter can be characterized by the type of thermometer it uses, and three types presently dominate the field. The first two types are temperature-sensitive resistors - semiconductors in the metal-insulator transition and superconductors operated in the superconducting-normal transition. The third type uses a paramagnetic thermometer. These types can be considered the three generations of x-ray calorimeters; by now each has demonstrated a resolving power of 2000 at 6 keV, but only a semiconductor calorimeter system has been developed to spaceflight readiness. The Soft X-ray Spectrometer on Astro-H, expected to launch in 2013, will use an array of silicon thermistors with I-IgTe x-ray absorbers that will operate at 50 mK. Both the semiconductor and superconductor calorimeters have been implemented in small arrays, kilo-pixel arrays of the superconducting calorimeters are just now being produced, and it is anticipated that much larger arrays will require the non-dissipative advantage of magnetic thermometers.

Kilbourne, Caroline A.↗

High-Precision Temperature Control of a Crystal Growth Furnace at 1,500 C

For crystal growth of semiconductor materials a short-term temperature stability of 0.1 C at 1500 C is one of the essential parameters to be addressed for achieving high-quality crystals. Hence, for temperature monitoring and control with high precision in a floating zone furnace two sets of thermo-sensors, type B thermocouples and optical fibre thermometers, have been implemented and successfully operated in the furnace for more than 2000 h. The optical fibre thermometers consist of an optical system made of sapphire (two fibres plus a prism in between for deflection) and transmit the infra-red radiation of the heater to the outside of the hot core of the furnace for pyrometric temperature measurement. A dedicated control algorithm has been set up which controlled the power settings to the individual heaters. Both sensor types showed no degradation after this period and yielded a short-term stability at 1200 C of 0.05 C (optical fibre thermometers), respectively 0.08 C (thermocouples).

Stenzel, Ch.↗

Future Development Trajectories for Imaging X-rays Spectrometers Based on Microcalorimeters

Future development trajectories for imaging x-ray spectrometers based on microcalorimeters. Since their invention 30 years ago, the capability of X-ray microcalorimeters has increased steadily, with continual improvements in energy resolution, speed, and array size. Arrays of up to 1024 pixels have been produced, and resolution better than 1 eV at 1.5 keV has been achieved. These detectors can be optimized for the highest priority science, such as designing for the highest resolving power at low energies at the expense of dynamic range, or the greatest focal-plane coverage at the expense of speed. Three types of X-ray microcalorimeters presently dominate the field, each characterized by the thermometer technology. The first two types use temperature-sensitive resistors: semiconductors in the metal-insulator transition and superconductors operated in the superconducting-normal transition. The third type uses a magnetically coupled thermometer, and is at an earlier stage of development than the other two. The Soft X-ray Spectrometer (SXS) on Astro-H, expected to launch in 2015, will use an array of silicon thermistors with HgTe X-ray absorbers that will operate at 50 mK. Both the semiconductor and superconductor calorimeters have been implemented in small arrays. Kilopixel arrays of the superconducting calorimeters are being produced, and much larger arrays may require the non-dissipative advantage of magnetically coupled thermometers. I will project the development trajectories of these detectors and their read-out technologies and assess what their capabilities and limitations will be 10 - 20 years from now.

Kilbourne, Caroline A.↗

A methodology for corrosion testing ODS steels in liquid tin under reactor conditions in HFIR

Liquid metal–based divertor concepts have promising attributes for application in fusion reactors. Liquid tin is being considered as one of those liquid metals due to its excellent thermophysical properties. However, tin is extremely corrosive to steels at elevated temperatures, and the coupled effects of corrosion with neutron irradiation for application in fusion reactors have not been quantified. Researchers at Oak Ridge National Laboratory (ORNL) have designed and irradiated a series of capsules in the High Flux Isotope Reactor (HFIR) to help address gaps in the literature with respect to coupled corrosion and neutron irradiation effects. The capsules are filled with solid tin designed to melt due to the gamma heating in HFIR and allow interaction with the specimens. The capsules contain a SiC thermometer for post-irradiation temperature verification. Five capsules were irradiated in HFIR for 10.5 days, accumulating 0.93 dpa in the FeCrAl specimens. Post-irradiation temperature verification was performed on the SiC thermometers, and temperatures were observed to be higher than what was expected from thermal models. An explanation for the model underprediction is given herein. In conclusion, the capsules described within this article are the first to irradiate liquid metal within the HFIR flux trap and demonstrated the safety basis for continued liquid coolant studies in HFIR.

FeCrAl↗

Barium stars as tracers of s -process nucleosynthesis in AGB stars

Barium (Ba) stars help to verify asymptotic giant branch (AGB) star nucleosynthesis models since they experienced pollution from an AGB binary companion and thus their spectra carry the signatures of the slow neutron capture process (s process). For a large number (180) of Ba stars, we searched for AGB stellar models that match the observed abundance patterns. We aim to uncover any systematic deviations of the sample abundances from the predictions of the nucleosynthesis models. We employed three machine learning algorithms as classifiers: a Random Forest method, developed for this work, and the two classifiers used in our previous study. Compared to that work, we also expanded our observational sample with 11 Ba stars available in the supersolar metallicity range. We studied the statistical behaviour of the different s-process elements in the observational sample to investigate if the AGB models systematically under- or overpredict the abundances observed in the Ba stars and show the results in the form of violin plots of the residuals between spectroscopic abundances and model predictions. We inspected the correlations between the observed [Fe/H], the s-process elemental abundances, and the residuals. We employed the [Zr/Fe] and [Nb/Fe] abundances as a thermometer to constrain the operational temperature that rules the production of these elements in the sample stars, assuming a steady-state s process. We also investigated the mass distribution of the identified polluter AGB stars and the behaviour of the δ parameter, which describes the fraction of accreted AGB material relative to the Ba star envelope. We find a significant trend in the residuals that implies an underproduction of the elements just after the first s-process peak (Nb, Mo, and Ru) in the models relative to the observations. This may originate from a neutron-capture process (e.g. the intermediate neutron-capture process, i process) not yet included in the AGB models of metallicity from solar to roughly 1/5 solar, corresponding to the range of the Ba stars. Correlations are found between the residuals of these peculiar elements, suggesting a common origin for the deviations from the models. In addition, there is a weak metallicity dependence of the residuals of these elements. The s-process temperatures derived with the [Zr/Fe] – [Nb/Fe] thermometer have an unrealistic value for the majority of our stars. The most likely explanation is that at least a fraction of these elements are not produced in a steady-state s process, and instead may be due to processes not included in the AGB models. The mass distribution of the identified models confirms that our sample of Ba stars was polluted by low-mass AGB stars (< 4 M ⊙ ). Most of the matching AGB models require low accreted mass, but a few systems with high accreted mass are needed to explain the observations.

79 ASTRONOMY AND ASTROPHYSICS↗

Quantifying the temperature of heated microdevices using scanning thermal probes

Quantifying the temperature of microdevices is critical for probing nanoscale energy transport. Such quantification is often accomplished by integrating resistance thermometers into microdevices. However, such thermometers frequently become structurally unstable and fail due to thermal stresses at elevated temperatures. Here, we show that custom-fabricated scanning thermal probes (STPs) with a sharp tip and an integrated heater/thermometer can accurately measure the temperature of microdevices held at elevated temperatures. This measurement is accomplished by introducing a modulated heat input to the STP after contacting the microdevice with the STP's tip and characterizing the DC and AC components of the STP's temperature. From these measured temperature components, the tip-to-sample thermal resistance and the microdevice surface temperature are deduced simultaneously via a simple lumped-capacitance model. The advances presented here can greatly facilitate temperature measurements of a variety of heated microdevices.

42 ENGINEERING↗

Optimization of gold germanium (Au 0.17 Ge 0.83 ) thin films for high sensitivity resistance thermometry

Gold–germanium (Au x Ge 1–x ) solid solutions have been demonstrated as highly sensitive thin film thermometers for cryogenic applications. However, little is known regarding the performance of the films for thicknesses less than 100 nm. In response, here we report on the resistivity and temperature coefficient of resistance (TCR) for sputtered films with thicknesses ranging from 10 to 100 nm and annealed at temperatures from 22 to 200°C. The analysis is focused upon composition x=0.17, which demonstrates a strong temperature sensitivity over a broad range. The thinnest films are found to provide an enhancement in TCR, which approaches 20% K –1 at 10 K. Furthermore, reduced anneal temperatures are required to crystallize the Ge matrix and achieve a maximum TCR for films of reduced thickness. These features favor the application of ultra-thin films as high-sensitivity, on-device thermometers in micro- and nanolectromechanical systems.

59 BASIC BIOLOGICAL SCIENCES↗

Operation Plumbbob

On June 24, 1957, a thirty-seven kiloton nuclear device, codenamed Priscilla, exploded 700 feet over the Nevada Test Site’s Frenchman dry lake. Below, on the lakebed, was a bank vault designed by the Mosler Safe Company for one of several Federal Civil Defense Administration experiments. The vault was constructed “to evaluate the effectiveness of a reinforced-concrete vault and steel vault door in providing protection against the effects of a nuclear detonation.” Blast damage to the exterior was largely confined to the side walls, whose concrete was stripped off; its steel reinforcing rods bent and twisted. The vault door was essentially undamaged and was opened with minimal difficulty. The vault contents - sandbags, movie camera, and thermometers - were only slightly disturbed. The camera operated as planned, running 40 ft of film. The film, however, was completely fogged. Two clinical type thermometers registered 88°F, and a 24-hr stylus American temperature recorder registered a constant 88°F. Priscilla was the fifth of twenty-nine tests conducted in 1957 as part of Operation Plumbbob, whose stated purpose was to conduct tests “aimed to attain new knowledge important to the defense of the United States and the Free World.” Individual events included “proof tests of air defense and antisubmarine warheads to be stockpiled, development tests of bomb components and mockups, and design tests of smaller and lighter warheads.” One test, John, was that of an air-to-air missile detonated 18,500 feet over the test site.

99 GENERAL AND MISCELLANEOUS↗

Solid State Quantum Refrigeration Superconducting, Absorption and Measurement Based (Final Technical Report)

During this DOE grant, DE-SC0017890, in place for the past six years, all proposed research was carried out and published in peer-reviewed papers, as well as other projects that emerged during the research. In that effort the research team accomplished all proposed research, as well as many closely related research projects discovered and conceived of during the grant. These works included “Efficient Quantum Measurement Engines”, a work published in Physical Review Letters, giving a theory of quantum measurement-based engines, which uses quantum measurement as a resource. These engines are designed to efficiently convert energy from the stochastic quantum measurement process into useful work. Further publications include “Experimental Realization of a Quantum Dot Energy Harvester”, a joint theory and experimental work in collaboration with the group of Charles Smith in Cambridge, UK, as well as long time theoretical collaborators, Rafael Sánchez and Björn Sothmann. This work, featured as an Editor’s Suggestion in Physical Review Letters, realized an earlier theoretical proposal of ours, whereby two resonant tunneling quantum dots are connected to a central electronic cavity that is heated by a hot energy source. We also published “Superconducting Quantum Refrigerator: Breaking and Rejoining Cooper Pairs with Magnetic Field Cycles” a work done in collaboration with experimentalist Francesco Giazotto from ENS Pisa, Italy, which also resulted in a patent. This paper, published in Phys. Rev. Applied, advanced the concept of a cyclic fridge based on the normal/superconducting phase transition together with layered materials separated by tunnel junctions. We also completed the proposed research on a heat transistor, publishing “Thermal transistor and thermometer based on Coulomb-coupled conductors”, carried out as a collaboration between my group and theorists Splettstoesser (Lund U., Sweden), Sothmann (U. Duisburg-Essen, Germany), and Sánchez (U. Autónoma de Madrid, Spain). We carried out an analysis of a quantum coupled to a quantum point contact as a sensitive thermometer and heat transistor. We found the optimal statistical estimator for the temperature and compared it with experiments on the same type of devices. We also investigated autonomous quantum absorption refrigerators using quantum dots to cool by using a very hot thermal reservoir to drive heat between two other reservoirs. In the article “Quantifying the quantum heat contribution from a driven superconducting circuit”, we demonstrated that for a driven superconducting circuit, we showed heat flow provided by a hot source to the qubit can be switched on and off by varying external parameters, the frequency and the intensity of the driving. In the work “Stochastic thermodynamic cycles of a mesoscopic thermoelectric engine”, we reconsidered the autonomous thermoelectric heat engine in terms of underlying cycles. Rather than periodic behavior, the cycles were stochastic in nature. Nevertheless, by undertaking a graph theoretical analysis of the elementary transport processed, great quantitative and qualitative insight could be found. We also considered the quantum measurement process and showed that a quantum version of Maxwell’s demon could be related to the work extraction of a quantum system, closely related to arrow-of-time measures for quantum measurement, as described in our article “Thermodynamics of quantum measurement and Maxwell's demon's arrow of time”. This work was selected in Phys. Rev. A as an Editor’s Suggestion. A recent preprint titled “Cyclic Superconducting Quantum Refrigerators Using Guided Fluxon Propagation” accomplished an important piece of this grant: to propose a new kind of quantum refrigerator using the dynamics of fluxons in a type II superconductor. This invention envisioned a race-track type geometry where fluxons are confined. By applying a gradient of magnetic field together with electric current in a Corbino geometry, the circulating fluxons can actively cool a cold reservoir, realizing a new type of cyclic superconducting refrigerator. We also investigated the possibility of thermal control from different points of view. The application of quantum measurement to the system gives a new kind of control on the system of interest – we have pioneered this approach and shown that measurement can boost the thermal power of quantum engines as described in “Continuous measurement boosted adiabatic quantum thermal machines”. The ability to have heat flows on demand is an outstanding challenge, and we have provided new solutions to this problem in Thermal control across a chain of electronic nanocavities” for a chain of electron cavities using gating voltage control. The control methods using qubit/qubit coupling to create absorption fridges at their most fundamental level have also been developed.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

High-Accuracy and High-Stability Fiber-Optic Temperature Sensors for Coal Fired Advanced Energy

A research team at Michigan State University, led by Dr. Ming Han, has developed a revolutionary fiber-optic thermometer for use in next-generation coal-fired power plants. Funded by the U.S. Department of Energy, this new sensor is designed to measure extremely high temperatures with unmatched accuracy and long-term stability. Unlike conventional optical sensors that can give false readings due to mechanical strain and often drift out of calibration at high heat, this new technology uses a sealed gas chamber as its core. By measuring the temperature-dependent properties of the gas (air or argon), the sensor’s readings remain absolute and reliable, completely unaffected by the physical stresses on the surrounding equipment. The breakthrough design eliminates the need for complex and costly correction systems. It represents a fundamental shift in sensing technology, paving the way for a primary thermometer that maintains calibration and provides foundational accuracy essential for advanced energy systems.

01 COAL, LIGNITE, AND PEAT↗

A device for rapid determination of thermophysical properties of phase-change wind-tunnel models

An experimental method for direct measurement of the thermophysical properties of wind tunnel heat transfer models was developed. The technique consists of placing the model under a bank of high intensity, radiant heaters so that the fast opening water cooled shutters, which isolate the heater bank from the model, allow a step-input heat rate to be applied. Measurements of the heat transfer rate coupled with a surface-temperature time history of the same material are sufficient to determine the material thermophysical properties. An infrared thermometer is used to measure model surface temperature and a slug calorimeter provides heat transfer rate information. The output from the infrared thermometer and calorimeter is then fed into an analog-to-digital converter which provides digitized data to a computer. This computer then calculates combined thermophysical properties and a teleprinter prints out all the data. Thus, results are available within 7 minutes of test initiation as opposed to the weeks or months required using prior techniques.

Creel, T. R., Jr.↗

A temperature fixed point near 58 C

Triple-point cell contrains about 300 g of high-purity succinontrile. Experiments show that lower 4 cm of thermometer well are virtually isothermal, making placement of thermometer not very critical. Bulb at bottom of well helps to prevent solid succinontrile mantel from slipping.

Glicksman, M. E.↗

Equilibration temperatures of the ordinary chondrites - A new evaluation

The novel calibrations of the Ca-pyroxene thermometer accomplished by Kretz (1982) and Lindsley (1983) are presently applied to 24 analyzed pyroxenes from 24 H6, L6, and LL6 chondrites. Both thermometers indicate that the H group equilibrated to significantly lower temperature (820-830 C) than the L and LL groups, yielding values of 860 C (Lindsley) to 930 C (Kretz).

Olsen, E. J.↗

Temperature-Sensitive Oscillator

Ingestible thermometer consists of oscillator with temperature-dependent frequency. Device is quartz-crystal oscillator, frequency of which changes in proportion to change in temperature. Temperature-Sensitive Oscillator with nearly linear temperature coefficient of frequency obtained by using high-speed, high-gain, programable operational amplifier such as OP-32 to produce temperature-varying reflected capacitance across quartz crystal. New, small, inexpensive, low-power, temperature-sension circuit suitable for use as ingestible thermometer for measuring internal body temperature.

Kleinberg, L. L.↗

Characterization of NTD germanium and ion-implanted Si bolometers at 0.3K and 0.1K

Bolometer elements were built and tested using NTD germanium and ion-implanted Si thermometer elements. The thermal links were made using aluminum wires and NbC(x)N(y) coated carbon fibers. The temperature dependence of the detector resistance, lead thermal conductivity, and heat capacity were measured. The dependence of the detector resistance on applied electric field was also measured. This, combined with the current-voltage curve for the detector, allowed the calculation of the detector responsivity. Known amounts of energy were deposited into the detector by allowing X-rays from the decay of Fe-55 to be thermalized in the detector. In the best-measured case, the predicted pulse height/measured height was 1.04 + or - .05. The noise at frequencies above 25 Hz in the NTD Ge was near that predicted by thermodynamics. The noise below 25 Hz has a 1/f character and may be in the carbon fiber/bolometer junction. The implanted detectors show some 1/f noise which depends on the total thermometer volume. Comparison between noise measurements and theory will be presented.

Moseley, H.↗

Radiation thermometry: The measurement problem

An overview of the theory and techniques of radiometric thermometry is presented. The characteristics of thermal radiators (targets) are discussed along with surface roughness and oxidation effects, fresnel reflection and subsurface effects in dielectrics. The effects of the optical medium between the radiating target and the radiation thermometer are characterized including atmospheric effects, ambient temperature and dust environment effects and the influence of measurement windows. The optical and photodetection components of radiation thermometers are described and techniques for the correction of emissivity effects are addressed.

Nutter, G. D.↗

IR fiber temperature sensing system

Infrared fiber optic pyrometry has become a practical reality using improved strength fluoride glass fibers. The addition of a plastic coating and rugged cabling allows the fibers to be used in the field. A detailed theoretical model of the infrared fiber optic pyrometer (non-contact or radiative thermometer) has been derived and compared with data produced by a prototype fluoride glass fiber radiative thermometer. Excellent agreement was obtained between theory and experiment over a temperature range of 30 to 700 C.

Tran, D. C.↗