A reliable workflow for improving nanoscale X-ray fluorescence tomographic analysis on nanoparticle-treated HeLa cells

Abstract Scanning X-ray fluorescence (XRF) tomography provides powerful characterization capabilities in evaluating elemental distribution and differentiating their inter- and intra-cellular interactions in a three-dimensional (3D) space. Scanning XRF tomography encounters practical challenges from the sample itself, where the range of rotation angles is limited by geometric constraints, involving sample substrates or nearby features either blocking or converging into the field of view. This study aims to develop a reliable and efficient workflow that can (1) expand the experimental window for nanoscale tomographic analysis of local areas of interest within a laterally extended specimen, and (2) bridge 3D analysis at micrometer and nanoscales on the same specimen. We demonstrate the workflow using a specimen of HeLa cells exposed to iron oxide core and titanium dioxide shell (Fe3O4/TiO2) nanocomposites. The workflow utilizes iterative and multiscale XRF data collection with intermediate sample processing by focused ion beam (FIB) sample preparation between measurements at different length scales. Initial assessment combined with precise sample manipulation via FIB allows direct removal of sample regions that are obstacles to both incident X-ray beam and outgoing XRF signals, which considerably improves the subsequent nanoscale tomography analysis. This multiscale analysis workflow has advanced bio-nanotechnology studies by providing deep insights into the interaction between nanocomposites and single cells at a subcellular level as well as statistical assessments from measuring a population of cells.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Characterization of a Pixelated Cadmium Telluride Detector System Using a Polychromatic X-Ray Source and Gold Nanoparticle-Loaded Phantoms for Benchtop X-Ray Fluorescence Imaging

In this paper, the imaging dose and scan time have been considered as the two major constraints for routine benchtop x-ray fluorescence computed tomography (XFCT) imaging. One way to address this issue is to acquire x-ray fluorescence (XRF) signals in parallel through a 2D array of single-crystal detectors or a pixelated detector along with the cone-beam x-ray source. To identify a detector system suitable for this purpose, a commercially available, fully spectroscopic cadmium telluride (CdTe) pixelated detector, HEXITEC (High-Energy X-ray Imaging Technology), was tested under the experimental conditions optimized for benchtop XFCT imaging of gold nanoparticles (GNPs). Specifically, two different parallel-hole stainless steel collimators were fabricated and coupled with the detector for seamless integration into our existing benchtop cone-beam XFCT system. After the detector deployment, this benchtop XFCT system was used to detect XRF photons from GNP-loaded phantoms. A pixel-merging algorithm was introduced to enhance the sensitivity of XRF photon detection thereby minimizing the scan time. The effect of pixel-level charge sharing correction algorithms was investigated within the context of benchtop XFCT imaging. The detector energy resolution, in terms of the full width at half maximum (FWHM) values at different gold K-shell XRF energies, was also determined. Of the two charge sharing correction algorithms examined, the charge sharing addition gave better sensitivity than the charge sharing discrimination (csd). On the other hand, under the current experimental conditions, the energy resolution of the HEXITEC detector was the best with the csd and estimated to be 1.56 keV FWHM at 66-69 keV photon energy. Overall, despite some degradation of the detector energy resolution (compared with typical single crystal CdTe detectors), the HEXITEC detector enabled parallel data acquisition under the experimental conditions typical of benchtop XFCT imaging and operated well within our benchtop XFCT setup.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Atomic layer deposition of 2D and 3D standards for synchrotron-based quantitative composition and structure analysis methods

Atomic layer deposition (ALD) is a scalable deposition technique known for producing uniform, conformal films of a wide range of compounds on nearly any substrate material. These traits make it an ideal deposition method for producing films to replace the National Institute of Standards and Technology (NIST) standards and create Standard Reference Materials (SRMs) on a wide range of relevant two-dimensional and three-dimensional substrates. The use of SRM from NIST for quantitative analysis of chemical composition using synchrotron based x-ray fluorescence (SR-XRF) and scanning transmission x-ray microscopy (STXM) is common. Such standards, however, can suffer from inhomogeneity in chemical composition and thickness and often require further calculations, based on sample mounting and detector geometry, to obtain quantitative results. These inhomogeneities negatively impact the reproducibility of the measurements and the quantitative measure itself. Utilizing Rutherford backscattering, x-ray reflectivity, quartz crystal microbalance, STXM, and SR-XRF, the authors show that ALD is capable of producing high quality standards that are homogenous over scales ranging from nanometers to 100s of micrometers.

Becker, Nicholas G.↗

Predicting Dynamic-to-Static Correction Factor from Petrophysical Data and Chemostratigraphy using Unsupervised Machine Learning

Estimating static mechanical properties of stratigraphic layers is critical for optimizing subsurface engineering applications. To estimate dynamic-to-static correction factor F ds (static-to-dynamic Young’s modulus ratio) across the Caney shale interval in Oklahoma, USA, we integrated triaxial test measurements and petrophysical data, including well logs and X-ray fluorescence (XRF) using unsupervised machine learning (ML). We used a novel workflow that includes principal component analysis (PCA) to reduce data set dimensionality of well logs and XRF data sets—both separately and combined—creating three scenarios, and later applied inverse distance weighting (IDW) to derive F ds profiles for these scenarios. Furthermore, we applied K-means clustering on each scenario to predict depositional facies, and built a stiffness zonation profile through chemostratigraphic analysis of the terrigenous elements to validate the predicted F ds . The predicted F ds profile from each scenario using the PCA-IDW method was compared with the constant F ds approach from our previous study by calculating the root mean square error (RMSE). The combined data sets scenario yielded the lowest RMSE value of 0.113, while the RMSE values for the well logs and XRF scenarios were 0.131 and 0.129, respectively. In addition, the predicted F ds from the XRF scenario well-matched the stiffness zonation from the chemostratigraphic analysis that was built using the optimized K-means clustering of nine clusters for that scenario. These methods and findings offer a valuable tool for refining lithological classification and improving the F ds profile, potentially enhancing drilling and stimulation strategies for subsurface energy engineering applications.

clastic rock↗

Technologies for pre-screening IAEA swipe samples

During the course of International Atomic Energy Agency (IAEA) inspections, many samples are taken for the purpose of verifying the declared facility activities and identifying any possible undeclared activities. One of these sampling techniques is the environmental swipe sample. Due to the large number of samples collected, and the amount of time that is required to analyze them, prioritizing these swipes in the field or upon receipt at the Network of Analytical Laboratories (NWAL) will allow sensitive or mission-critical analyses to be performed sooner. As a result of this study, technologies were placed into one of three categories: recommended, promising, or not recommended. Both neutron activation analysis (NAA) and X-ray fluorescence (XRF) are recommended for further study and possible field deployment. These techniques performed the best in initial trials for pre-screening and prioritizing IAEA swipes. We learned that for NAA more characterization of cold elements (such as calcium and magnesium) would need to be emphasized, and for XRF it may be appropriate to move towards a benchtop XRF versus a handheld XRF due to the increased range of elements available on benchtop equipment. Promising techniques that will require additional research and development include confocal Raman microscopy, fluorescence microscopy, and infrared (IR) microscopy. These techniques showed substantive responses to uranium compounds, but expensive instrumentation upgrades (confocal Raman) or university engagement (fluorescence microscopy) may be necessary to investigate the utility of the techniques completely. Point-and-shoot (handheld) Raman and attenuated total reflectance–infrared (ATR-IR) measurements are not recommended, as they have not shown enough promise to continue investigations.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Progress in Genetic Algorithm Fitting of X-Ray Fluorescence Data for Absorption Spectroscopy of Liquid Surfaces

X-ray fluorescence (XRF) spectroscopy of liquid surfaces is a promising approach to elemental analysis of forensic samples. Elements in the mixture can be identified from the XRF data because chemical elements are associated with unique spectra. This report describes progress in the development of automated identification of unknown mixtures of elements from XRF spectra using a genetic algorithm (GA). The XRF spectra are measured at the Advanced Photon Source (APS) at the liquid-liquid interface during solvent extraction process. The usage of the GA is demonstrated and future implementation for related problems are then discussed.

47 OTHER INSTRUMENTATION↗

X-ray fluorescence analysis of wear metals in used lubricating oils

Used oils from several aircraft at NASA's Langley Research Center were analyzed over a three year period using X-ray fluorescence (XRF) and atomic emission spectrometry. The results of both analyses are presented and comparisons are made. Fe and Cu data for oil from four internal combustion engines are provided and XRF and atomic emission spectrometry measurements were found to be in perfect agreement. However, distributions were found in the case of oil from a jet aircraft engine whereby the latter method gave values for total iron concentration in the oil and did not distinguish between suspended particles and oil additives. XRF does not have these particle-size limitations; moreover, it is a faster process. It is concluded that XRF is the preferred method in the construction of a man-portable oil wear analysis instrument.

Maddox, W. E.↗

Possible use of pattern recognition for the analysis of Mars rover X-ray fluorescence spectra

On the Mars rover sample-return mission, the rover vehicle will collect and select samples from different locations on the Martian surface to be brought back to earth for laboratory studies. It is anticipated that an in situ energy-dispersive X-ray fluorescence (XRF) spectrometer will be on board the rover. On such a mission, sample selection is of higher priority than in situ quantitative chemical anlaysis. With this in mind, a pattern recognition technique is proposed as a simple, direct, and speedy alternative to detailed chemical analysis of the XRF spectra. The validity and efficacy of the pattern recognition technique are demonstrated by the analyses of laboratory XRF spectra obtained from a series of geological samples, in the form both of standardized pressed pellets and as unprepared rocks. It is found that pattern recognition techniques applied to the raw XRF spectra can provide for the same discrimination among samples as a knowledge of their actual chemical composition.

Yin, Lo I↗

In Situ Identification of Mineral Resources with an X-Ray-Optical "Hands-Lens" Instrument

The recognition of material resources on a planetary surface requires exploration strategies not dissimilar to those employed by early field geologists who searched for ore deposits primarily from surface clues. In order to determine the location of mineral ores or other materials, it will be necessary to characterize host terranes at regional or subregional scales. This requires geographically broad surveys in which statistically significant numbers of samples are rapidly scanned from a roving platform. To enable broad-scale, yet power-conservative planetary-surface exploration, we are developing an instrument that combines x-ray diffractometry (XRD), x-ray fluorescence spectrometry (XRF), and optical capabilities; the instrument can be deployed at the end of a rover's robotic arm, without the need for sample capture or preparation. The instrument provides XRD data for identification of mineral species and lithological types; diffractometry of minerals is conducted by ascertaining the characteristic lattice parameters or "d-spacings" of mineral compounds. D-spacings of 1.4 to 25 angstroms can be determined to include the large molecular structures of hydrated minerals such as clays. The XRF data will identify elements ranging from carbon (Atomic Number = 6) to elements as heavy as barium (Atomic Number = 56). While a sample is being x-rayed, the instrument simultaneously acquires an optical image of the sample surface at magnifications from lx to at least 50x (200x being feasible, depending on the sample surface). We believe that imaging the sample is extremely important as corroborative sample-identification data (the need for this capability having been illustrated by the experience of the Pathfinder rover). Very few geologists would rely on instrument data for sample identification without having seen the sample. Visual inspection provides critical recognition data such as texture, crystallinity, granularity, porosity, vesicularity, color, lustre, opacity, and so forth. These data can immediately distinguish sedimentary from igneous rocks, for example, and can thus eliminate geochemical or mineral ambiguities arising, say between arkose and granite. It would be important to know if the clay being analyzed was part of a uniform varve deposit laid down in a quiescent lake, or the matrix of a megabreccia diamictite deposited as a catastrophic impact ejecta blanket. The unique design of the instrument, which combines Debye-Scherrer geometry with elements of standard goniometry, negates the need for sample preparation of any kind, and thus negates the need for power-hungry and mechanically-complex sampling systems that would have to chip, crush, sieve, and mount the sample for x-ray analysis. Instead, the instrument is simply rested on the sample surface of interest (like a hand lens); the device can interrogate rough rock surfaces, coarse granular material, or fine rock flour. A breadboard version of the instrument has been deployed from the robotic arm of the Marsokhod rover in field trials at NASA Ames, where large vesicular boulders were x-rayed to demonstrate the functionality of the instrument design, and the ability of such a device to comply with constraints imposed by a roving platform. Currently under development is a flight prototype concept of this instrument that will weigh 0.3 kg, using about 4500 J of energy per sample analysis. It requires about 5 min. for XRD analysis, and about 30 min. for XRF interrogation. Its small mass and rugged design make it ideal for deployment on small rovers of the type currently envisaged for the exploration of Mars (e.g., Sojourner-scale platforms). The design utilizes a monolithic P-N junction photodiode pixel array for XRD, a Si PIN photodiode/avalanche photodiode system for XRF, and an endoscopic imaging camera system unobtrusively embedded between the detectors and the x-ray source (the endoscope with its board-mounted camera can be adapted for IR light in addition to visible wavelenths. A rugged, miniature (7 cu cm) x-ray source for the instrument has already been breadboarded.

Marshall, J.↗

A Review of the Handheld X-Ray Fluorescence Spectrometer as a Tool for Field Geologic Investigations on Earth and in Planetary Surface Exploration

X-ray fluorescence (XRF) spectroscopy is a well-established and commonly used technique in obtaining diagnostic compositional data on geological samples. Recently, developments in X-ray tube and detector technologies have resulted in miniaturized, field-portable instruments that enable new applications both in and out of standard laboratory settings. These applications, however, have not been extensively applied to geologic field campaigns. This study investigates the feasibility of using developing handheld XRF (hXRF) technology to enhance terrestrial field geology, with potential applications in planetary surface exploration missions. We demonstrate that the hXRF is quite stable, providing reliable and accurate data continuously over a several year period. Additionally, sample preparation is proved to have a marked effect on the strategy for collecting and assimilating hXRF data. While the hXRF is capable of obtaining data that are comparable to laboratory XRF analysis for several geologically-important elements (such as Si, Ca, Ti, and K), the instrument is unable to detect other elements (such as Mg and Na) reliably. While this limits the use of the hXRF, especially when compared to laboratory XRF techniques, the hXRF is still capable of providing the field user with significantly improved contextual awareness of a field site, and more work is needed to fully evaluate the potential of this instrument in more complex geologic environments.

Young, Kelsey E.↗

CubeX: A Compact X-Ray Telescope Enables Both X-Ray Fluorescence Imaging Spectroscopy and Pulsar Timing Based Navigation

This paper describes the miniaturized X-ray telescope payload, CubeX, in the context of a lunar mission. The first part describes the payload in detail, the second part summarizes a small satellite mission concept that utilizes its compact form factor and performance. This instrument can be used for both X-ray fluorescence (XRF) imaging spectroscopy and X-ray pulsar timing-based navigation (XNAV). It combines high angular resolution (<1 arcminutes) Miniature Wolter-I X-ray optics (MiXO) with a common focal plane consisting of high spectral resolution (<150 eV at 1 keV) CMOS X-ray sensors and a high timing resolution (< 1 μsec) SDD X-ray sensor. This novel combination of the instruments enables both XRF measurements and XNAV operations without moving parts, in a small form factor (~1×1×6U, <6 kg). In this paper we illustrate one potential application for a lunar mission concept: The elemental composition of the Moon holds keys to understanding the origin and evolution of both the Moon and the Earth. X-ray fluorescence (XRF), induced either by solar X-ray flux or energetic ions, carries decisive signatures of surface elemental composition. In between XRF observations, CubeX also leverages the technology of high resolution X-ray imaging and time series measurements to conduct XNAV operations and evaluate their performance.

Lunar Science↗

Cubex: A Compact X-Ray Telescope Enables Both X-Ray Fluorescence Imaging Spectroscopy and Pulsar Timing Based Navigation

This paper describes the miniaturized X-ray telescope payload, CubeX, in the context of a lunar mission. The first part describes the payload in detail, the second part summarizes a small satellite mission concept that utilizes its compact form factor and performance. This instrument can be used for both X-ray fluorescence (XRF) imaging spectroscopy and X-ray pulsar timing-based navigation (XNAV). It combines high angular resolution (<1 arcminutes) Miniature Wolter-I X-ray optics (MiXO) with a common focal plane consisting of high spectral resolution (<150 eV at 1 keV) CMOS X-ray sensors and a high timing resolution (< 1 Amp-microsecond) SDD X-ray sensor. This novel combination of the instruments enables both XRF measurements and XNAV operations without moving parts, in a small form factor (volume approximately 1 by 1 by 6 Units, and mass, < 6 kg). In this paper we illustrate one potential application for a lunar mission concept: The elemental composition of the Moon holds keys to understanding the origin and evolution of both the Moon and the Earth. X-ray fluorescence (XRF), induced either by solar X-ray flux or energetic ions, carries decisive signatures of surface elemental composition. In between XRF observations, CubeX also leverages the technology of high resolution X-ray imaging and time series measurements to conduct XNAV operations and evaluate their performance.

X-ray Fluorescence↗

Mineralogical, Elemental, and Tomographic Reconnaissance Investigation for CLPS (METRIC)

METRIC is a robotic science laboratory that can determine the mineralogy, elemental chemistry, micromorphology, and thermophysical properties of planetary regolith. The METRIC suite comprises METRIC XRD/F, an X-ray diffraction/X-ray fluorescence instrument that can determine the mineralogy and elemental chemistry of regolith samples; METRIC XCT, a micro X-ray computed tomography instrument that can be used to evaluate grain/crystallite sizes and textures; METRIC IRS, an imaging spectrometer mounted on a rover that can determine mineralogy and thermophysical properties at the landing site; and a pneumatic sample collection, processing, distribution system developed by Honeybee Robotics. The payload elements could be deployed on a static lander or a rover. Data returned from the METRIC payload would inform origin, formation, and evolution of rocky planetary bodies. METRIC XRD/F draws on heritage from the CheMin instrument on the Mars Science Laboratory (MSL) Curiosity rover [1], with a few important improvements. Like CheMin, METRIC XRD/F operates in transmission geometry and uses piezoelectric actuators on sample cells in a tuning fork geometry to induce convective grain motion of the regolith to create a randomly oriented powder. MSL CheMin uses an energy-sensitive CCD to collect XRD patterns and XRF spectra simultaneously from the same sample cell, resulting in qualitative XRF data. METRIC XRD/F uses two different sample cells, one optimized for XRD and one optimized for XRF, and a silicon drift detector to detect fluoresced X-rays. This improvement to the XRF capabilities provides quantitative geochemical data of major elements down to Z = 11 and allows for the detection of minor and trace elements that are critical for evaluating geologic evolution of the Moon (e.g., P and Th). Modest improvements to the XRD geometry and hardware allow for better angular resolution and the ability to distinguish between members of the pyroxene group. METRIC XCT uses the same geometry and much of the same hardware as METRIC XRD/F, where a CCD would capture images of a regolith sample in a 3 mm diameter sample tube that is rotated 360° in steps <1°. Image brightness can be used to infer compositional data, where brighter materials indicate a higher Z, much like scanning electron microscopy. Data from METRIC XCT complement those from METRIC XRD/F. Particle size, shape, and texture can provide petrologic and provenance information, whereas vesicle size and morphology in volcanic or impact melt lithologies can inform cooling rates. METRIC IRS is a hyperspectral thermal imager that can be mounted to a lander or rover to provide mineralogical data from the broader landing site and help determine whether the samples analyzed by METRIC XRD/F and XCT are representative. The METRIC IRS spectral range (8–14 μm) and resolution (10.8 cm-1) allow for quantitative mineralogy from modelling Reststrahlen bands of major rock-forming minerals (e.g., silicates, phosphates). Radiance cubes can be processed and modelled with an onboard high-performance computer to determine mineral abundances of plagioclase, high-Ca pyroxene, pigeonite, orthopyroxene, olivine, and glass. Regolith samples can be acquired, processed, and delivered to the X-ray instruments via multiple sample handling systems, but the pneumatic sampling systems developed by Honeybee Robotics [e.g., 2] are best suited for relatively low-cost missions that are being competed for the Moon (e.g., NASA’s Payloads and Research Investigations for the Surface of the Moon program). There are pneumatic sampling systems that collect surface material and other systems that pneumatically drill up to ~1 m below the surface, providing material that has not been space weathered and has not been affected by the lander’s exhaust. [1] Blake, D. F., Vaniman, D., Achilles, C., Anderson, R., Bish, D., et al. (2012). Space Sci. Rev. 170, 341-478. https://doi.org/10.1007/s11214-012-9905-1. [2] Zacny, K., Betts, B., Hedlund, M., Long, P., Gramlich, M., Tura, K., Chu, P., Jacob, A., Garcia, A. (2014). IEEE Aerospace Conference, 3-7 March 2014, Big Sky, MT, U.S.A.

X-ray diffraction↗

In-Situ XRD/XRF to Support Life Detection on Mars

X-ray diffraction / X-ray fluorescence (XRD/XRF) analysis provides the most comprehensive mineralogical / compositional characterization of rocks and soils of any flight-capable technique. XRD data provide quantitative mineralogy (including abundance of X-ray amorphous materials) and crystal chemistry (structure, elemental composition and valence state), and XRF data provide complimentary major, minor, and some trace element abundances. Both types of data are important in evaluating habitability (environment of formation) and biosignature preservation/degradation (post-depositional diagenetic change). Whether or not a relict biosignature is detected, the mineral assemblage and its geochemistry can be used to determine the habitability of an ancient environment (e.g., salinity, pH, temperature), and to identify potential sources of energy for life (e.g., elements in different redox states). In this respect, a null result (a habitable environment lacking evidence of life) can play an important role in constraining the parameters of the search. Conversely, diagenetic alteration (taphonomic change) resulting from post-depositional variations in temperature, pressure or fluid chemistry can preserve evidence of biogenicity, erase such evidence completely or indeed can provide for post-depositional habitable conditions in the subsurface. XRD / XRF data are critical to these determinations. The CheMin instrument on the Mars Science Laboratory (MSL) Curiosity rover is the first XRD instrument flown in space. CheMin operates in transmission geometry with a Co X-ray source to minimize fluorescence from iron. Diffracted photons are collected with an energy-sensitive charge-coupled device (CCD). The position of the diffracted photons provides structural information for minerals, whereas the energy of sample-generated X-ray fluorescence photons provides elemental information, though these XRF data are qualitative. Mineralogical data from the CheMin XRD identified the three circumstances above: habitable depositional environments (e.g., Yellowknife Bay), habitable subsurface/diagenetic environments (e.g., throughout the Murray formation), and diagenetic conditions that may destroy evidence of habitability (e.g., oxidative and acidic environments at Vera Rubin ridge). Technological advances in X-ray technology and lessons learned from the operation of CheMin on Mars have resulted in a next-generation XRD/XRF, called CheMinX. Replacement of CheMin’s CCD with an array of hybrid pixel detectors and improvements in focusing optics dramatically decrease analysis time (15 minutes vs. 22 hours for MSL-CheMin) and result in a better angular resolution (0.18 vs. 0.30 °2θ for MSL-CheMin). This increased resolution improves mineral detection, including discrimination between types of pyroxenes, which is not possible with MSL-CheMin data. The hybrid pixel detectors do not require cooling like the MSL-CheMin CCD, therefore reducing the power needed to operate CheMinX. CheMinX has a silicon-drift detector (SDD) to measure fluoresced photons, enabling the quantification of major, minor, and some trace elements via XRF. XRD/XRF data are collected simultaneously in CheMinX, obviating the need for multiple compositional instruments. The CheMinX design also improves upon MSL-CheMin’s sample handling. Instead of sample cells on wheel, which are often not reusable and add complexity in commanding the instrument, CheMinX has single-use cells in a cartridge/dispenser configuration. Because of these improvements, CheMinX is an ideal instrument for Discovery-class life-detection missions, including Mars Life Explorer that was recommended for development in the Planetary Science and Astrobiology Decadal Survey 2023-2032.

E B Rampe↗

Archimedes Brought to Light

Just over 100 years ago in the summer of 1906, a Danish scholar called Johan Ludvig Heiberg travelled to the famous Metochion library of the Church of the Holy Sepulcher in Constantinople. He had got wind of an intriguing medieval prayer book that had recently been found at the library, and which contained a series of Christian prayers written on parchment recycled from older books. But underneath the scrawlings of a 13th-century medieval monk, the battered manuscript also appeared to contain some strange Greek writing as well as mysterious drawings and mathematical symbols. When Heiberg saw the book, he soon realized that the hidden material in fact contained the thoughts of Archimedes of Syracuse (287-212 BC) - one of the greatest thinkers of the ancient world. It was in November 2003, while on my way to a conference in Germany, that I first realized that the technique might help to uncover the hidden writings in the Archimedes Palimpsest. I had been reading an article in the German magazine GEO about the manuscript and, having previously used X-rays to detect metals in biological systems, realized that XRF could help to detect iron and other common elements in the ink. I immediately e-mailed Abigail Quandt, a conservator at the Walters Art Museum, who was part of a team that had been put in charge of the Archimedes manuscript. I was delighted to find that the team, led by her colleague William Noel, was looking for new ways to study this ancient book. Indeed, it turned out that two other researchers - Gene Hall from Rutgers University and Bob Morton from the oil firm ConocoPhillips - had also suggested using XRF imaging. Another team member - Johns Hopkins University physicist Bill Christens-Barry - had already been thinking of using X-rays too. In March 2004 Hall and the team carried out the first tests on the Palimpsest using X-rays from a commercial generator. Although these tests were promising, the results confirmed my belief that synchrotron radiation could be much better because it would allow the book to be scanned much faster and with higher resolution. Indeed, I had already begun collaborating with my SLAC colleague Martin George, who helped to develop an XRF system that could image and scan the Palimpsest at high speed. It consisted of a computer-controlled stage that could hold a single leaf from the book and be moved from side to side so that the X-ray beam from SLAC's powerful SPEAR3 accelerator could be scanned across the sample. A 2D image of the page could then be built up by plotting the intensity of the fluorescent X-rays at a particular energy. The problem with imaging a delicate object like the Palimpsest using intense beams of X-rays is that it can be damaged if exposed for too long. Working with Gregory Young from the Conservation Institute in Ottawa, Canada, we carried out tests on a piece of parchment from a will written in 1870 that had been given to us by Quandt at the Walters Art Museum from her private collection. We found that if the parchment is moved sufficiently quickly so that the beam dwells for no longer than 0.1 s on every area through which it is passing, then no measurable damage occurs to the document's fibers. The only snag was that when the beam reached the edges of a particular line of the document, the stage holding the individual pages had to stop briefly and step down to the next line - a process that could take as long as 1 s. To avoid overexposure during these stops, we added a fast pneumatic beam shutter to the computerized scanning system, which remained open only when the parchment was moving. Our tests at SLAC proved so successful that we were able to persuade the Archimedes team to let us use our equipment on the real Palimpsest. The team arrived in May 2005 with 3 test pages and we were soon able to image half of one page at a resolution of 250 dots per centimeter in just 30 hours (Nature 435 257). We then used algorithms developed by Keith Knox, a physicist from Boeing, to convert the raw data into 2D images. In all of our measurements we were most interested in the fluorescence from iron, which is the most common element in the ink. But by placing suitable electronic 'windows' on the detector, we were able to simultaneously also record the signal from other elements, including calcium, zinc, barium and copper. The iron XRF image clearly revealed Archimedes writing under one of the forged paintings that had been added in the 20th century and - in the next two runs during March and August last year - we were able to scan various texts that could not be revealed with other techniques as well as some writings that do not appear anywhere else. By installing better detectors and by including a new readout system that had been developed by our colleague Alex Garachtchenko, we can now scan a whole page in just 12 hours with the X-ray beam sweeping over each 40 {micro}m2 area of the sample in just 3 ms.

43 PARTICLE ACCELERATORS↗

Black manganese-rich crusts on a Gothic cathedral

Black manganese-rich crusts are found worldwide on the façades of historical buildings. Here, they were studied exemplarily on the façade of the Freiburger Münster (Freiburg Minster), Germany, and measured in-situ by portable X-ray fluorescence (XRF). The XRF was calibrated to allow the conversion from apparent mass fractions to Mn surface density (Mn mass per area), to compensate for the fact that portable XRF mass fraction measurements from thin layers violate the assumption of a homogeneous measurement volume. Additionally, 200-nm femtosecond laser ablation-inductively coupled plasma-mass spectrometry (fs LA-ICP-MS) measurements, scanning transmission X-ray microscopy-near edge X-ray absorption fine structure spectroscopy (STXM-NEXAFS), Raman spectroscopy, and imaging by light microscopy were conducted to obtain further insight into the crust material, such as potential biogenic contributions, element distributions, trace element compositions, and organic functional groups. While black crusts of various types are present at many places on the minster's facade, crusts rich in Mn (with a Mn surface density >150 μg cm -2 ) are restricted to a maximum height of about 7 m. The only exceptions are those developed on the Renaissance-Vorhalle (Renaissance Portico) at a height of about 8 m. This part of the façade had been cleaned and treated with a silicon resin as recently as 2003. These crusts thus accumulated over a period of only 12 years. Yet, they are exceptionally Mn-rich with a surface density of 1200 μg cm -2 , and therefore require an accumulation rate of about 100 μg cm -2 Mn per year. Trace element analyses support the theory that vehicle emissions are responsible for most of the Mn supply. Lead, barium, and zinc correlate with manganese, indicating that tire material, brake pads, and resuspended road dust are likely to be the element sources. Microscopic investigations show no organisms on or in the Mn-rich crusts. In contrast, Mn-free black crusts sampled at greater heights (>8 m) exhibited fungal and cyanobacterial encrustation. Carbon-rich spots were found by STXM-NEXAFS underneath one of the Mn-rich crusts. Yet, these carbon occurrences originate from soot and polycyclic aromatic hydrocarbons (PAHs) deposited on top of the crust, rather than from organisms responsible for the crust's formation, as shown by STXM-NEXAFS and Raman spectroscopic measurements. Our results imply that the crusts develop abiogenically, with vehicle emissions as dominant element sources.

58 GEOSCIENCES↗

Supplemental macronutrients and microbial fermentation products improve the uptake and transport of foliar applied zinc in sunflower ( Helianthus annuus L.) plants. Studies utilizing micro X-ray florescence

Enhancing nutrient uptake and the subsequent elemental transport from the sites of application to sites of utilization is of great importance to the science and practical field application of foliar fertilizers. The aim of this study was to investigate the mobility of various foliar applied zinc (Zn) formulations in sunflower ( Helianthus annuus L.) and to evaluate the effects of the addition of an organic biostimulant on phloem loading and elemental mobility. This was achieved by application of foliar formulations to the blade of sunflower ( H. annuus L.) and high-resolution elemental imaging with micro X-ray fluorescence (μ-XRF) to visualize Zn within the vascular system of the leaf petiole. Although no significant increase of total Zn in petioles was determined by inductively-coupled plasma mass-spectrometer, μ-XRF elemental imaging showed a clear enrichment of Zn in the vascular tissues within the sunflower petioles treated with foliar fertilizers containing Zn. The concentration of Zn in the vascular of sunflower petioles was increased when Zn was applied with other microelements with EDTA (commercial product Kick-Off) as compared with an equimolar concentration of ZnSO₄ alone. The addition of macronutrients N, P, K (commercial product CleanStart) to the Kick-Off Zn fertilizer, further increased vascular system Zn concentrations while the addition of the microbially derived organic biostimulant “GroZyme” resulted in a remarkable enhancement of Zn concentrations in the petiole vascular system. The study provides direct visualized evidence for phloem transport of foliar applied Zn out of sites of application in plants by using μ-XRF technique, and suggests that the formulation of the foliar applied Zn and the addition of the organic biostimulant GroZyme increases the mobility of Zn following its absorption by the leaf of sunflower.

59 BASIC BIOLOGICAL SCIENCES↗