Search NASA⌕ Search

SEARCH · Search NASA

Results for “capillary flows”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 163 records · Page 9

Quasi non-intrusive sampling and analysis of gases associated with the boundary layer on the tethered satellite and similar supersonic and hypersonic research vehicles

The effect that one candidate inlet, an assembly of capillary openings in a thin glass plate (a multichannel plate), might have on the overall sampling process is considered. The flow characteristics of the plate, under a variety of conditions of external pressure and mass flow, is evaluated. A review of capillary flow theory is presented with some development of the pertinent equations. The predicted mass flow will be compared to that determined perimentally to assess the effect that mass flow through one capillary might have upon a neighboring capillary. Mass spectrometric measurements of mixtures flowing through the multichannel plate (MCP) is also considered. In the first part of the experiments, the flow was in a direction normal to the surface of the plate. The experimental gases were Argon and mixtures of carbon dioxide in air. Ongoing experiments are discussed which are conducted with the flow parallel to the surface of the plate, a simulation of the kind of flow that a flight vehicle would experience.

Fishel, C.↗

An analysis of estimation of pulmonary blood flow by the single-breath method

The single-breath method represents a simple noninvasive technique for the assessment of capillary blood flow across the lung. However, this method has not gained widespread acceptance, because its accuracy is still being questioned. A rigorous procedure is described for estimating pulmonary blood flow (PBF) using data obtained with the aid of the single-breath method. Attention is given to the minimization of data-processing errors in the presence of measurement errors and to questions regarding a correction for possible loss of CO2 in the lung tissue. It is pointed out that the estimations are based on the exact solution of the underlying differential equations which describe the dynamics of gas exchange in the lung. The reported study demonstrates the feasibility of obtaining highly reliable estimates of PBF from expiratory data in the presence of random measurement errors.

Srinivasan, R.↗

Highly sensitive silicon microreactor for catalyst testing

A novel microfabricated chemical reactor for highly sensitive measurements of catalytic activity and surface kinetics is presented. The reactor is fabricated in a silicon chip and is intended for gas-phase reactions at pressures ranging from 0.1 to 5.0 bar. A high sensitivity is obtained by directing the entire gas flow through the catalyst bed to a mass spectrometer, thus ensuring that nearly all reaction products are present in the analyzed gas flow. Although the device can be employed for testing a wide range of catalysts, the primary aim of the design is to allow characterization of model catalysts which can only be obtained in small quantities. Such measurements are of significant fundamental interest but are challenging because of the low surface areas involved. The relationship between the reaction zone gas flow and the pressure in the reaction zone is investigated experimentally. A corresponding theoretical model is presented, and the gas flow through an on-chip flow-limiting capillary is predicted to be in the intermediate regime. The experimental data for the gas flow are found to be in good agreement with the theoretical model. At typical experimental conditions, the total gas flow through the reaction zone is around 3x10{sup 14} molecules s{sup -1}, corresponding to a gas residence time in the reaction zone of about 11 s. To demonstrate the operation of the microreactor, CO oxidation on low-area platinum thin film circles is employed as a test reaction. Using temperature ramping, it is found that platinum catalysts with areas as small as 15 {mu}m{sup 2} are conveniently characterized with the device.

36 MATERIALS SCIENCE↗

Ceramic Wick For Capillary-Pumped Heat Pipe

Fibrous ceramic wick allows choice of working fluid and high-temperature fabrication and/or operation. Wick material resists degradation at temperatures from -195 to +1,500 degrees C. Liquid refrigerant fills bore of silica/alumina wick. After flowing by capillary action through pores of wick, refrigerant evaporates from finned outer surface of wick and enters heat pipe, flowing toward condenser section.

Seidenberg, Benjamin↗

Effect of Recombinant Human Endostatin on Radiosensitivity in Patients With Non-Small-Cell Lung Cancer

Purpose: To observe the effects of recombinant human endostatin (RHES) on the radiosensitivity of non-small cell lung cancer (NSCLC). Methods and Materials: First, 10 hypoxia-positive cases of pathology-diagnosed NSCLC selected from 15 patients were used to determine the normalization window, a period during which RHES improves NSCLC hypoxia. Second, 50 hypoxia-positive cases of pathology-diagnosed NSCLC (Stages I-III) were randomly divided into a RHES plus radiotherapy group (25 cases) and a radiotherapy-alone group (25 cases). Intensity = modulated radiotherapy with a total dose of 60 Gy in 30 fractions for 6 weeks was adopted in the two groups. The target area included primary foci and metastatic lymph nodes. In the RHES plus radiotherapy group, RHES (15 mg/day) was intravenously given during the normalization window. Results: After RHES administration, the tumor-to=normal tissue radioactivity ratio and capillary permeability surface were first decreased and then increased, with their lowest points on the fifth day compared with the first day (all p < 0.01). Blood flow was first increased and then decreased, with the highest point on the fifth day, compared with the first and tenth day (all p < 0.01). In the RHES plus radiotherapy group and the radiotherapy-alone group, the total effective rates (complete response plus partial response) were 80% and 44% (p = 0.009), respectively. The median survival times were 21.1 {+-} 0.97 months and 16.5 {+-} 0.95 months (p = 0.004), respectively. The 1-year and 2-year local control rates were 78.9 {+-} 8.4% and 68.1 {+-} 7.8% (p = 0.027) and 63.6 {+-} 7.2% and 43.4 {+-} 5.7% (p = 0.022), respectively. The 1-year and 2-year overall survival rates were 83.3 {+-} 7.2% and 76.6 {+-} 9.3% (p = 0.247) and 46.3 {+-} 2.4% and 37.6 {+-} 9.1% (p = 0.218), respectively. Conclusion: The RHES normalization window is within about 1 week after administration. RHES combined with radiotherapy within the normalization window has better short-term therapeutic effects and local control rates and no severe adverse reactions in the treatment of NSCLC, but it failed to significantly improve the 1-year and 3-year overall survival rates.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Wettability impact on supercritical CO 2 capillary trapping: Pore-scale visualization and quantification

How the wettability of pore surfaces affects supercritical (sc) CO 2 capillary trapping in geologic carbon sequestration (GCS) is not well understood, and available evidence appears inconsistent. Using a high-pressure micromodel-microscopy system with image analysis, we studied the impact of wettability on scCO 2 capillary trapping during short-term brine flooding (80 s, 8–667 pore volumes). Experiments on brine displacing scCO 2 were conducted at 8.5 MPa and 45°C in water-wet (static contact angle $\theta$ $20° ± 8°$) and intermediate-wet ($\theta$ $94° ± 13°$) homogeneous micromodels under four different flow rates (capillary number Ca ranging from 9 x 10 -6 to 8 x 10 -4 ) with a total of eight conditions (four replicates for each). Brine invasion processes were recorded and statistical analysis was performed for over 2000 images of scCO 2 saturations, and scCO 2 cluster characteristics. The trapped scCO 2 saturation under intermediate-wet conditions is 15% higher than under water-wet conditions under the slowest flow rate ( Ca 9 x 10 -6 ). Based on the visualization and scCO 2 cluster analysis, we show that the scCO 2 trapping process in our micromodels is governed by bypass trapping that is enhanced by the larger contact angle. Smaller contact angles enhance cooperative pore filling and widen brine fingers (or channels), leading to smaller volumes of scCO 2 being bypassed. Increased flow rates suppress this wettability effect.

54 ENVIRONMENTAL SCIENCES↗

Voltage and pressure scaling of streamer dynamics in a helium plasma jet with N{sub 2} co-flow

Positive polarity applied voltage and gas pressure dependent scaling of cathode directed streamer propagation properties in helium gas flow guided capillary dielectric barrier discharge have been quantified from streamer velocity, streamer current, and streamer optical diameter measurements. All measurements of the non-stochastic streamer properties have been performed in a variable gas pressure glass cell with N{sub 2} co-flow and under self-consistent Poisson electric field dominated conditions to permit data comparison with 2-D streamer dynamics models in air/nitrogen. The streamer optical diameter was found to be nearly independent of both gas pressures, from 170 Torr up to 760 Torr, and also for applied voltages from 6 to 11 kV at 520 Torr. The streamer velocity was found to increase quadratically with increased applied voltage. These observed differences in the 2-D scaling properties of ionization wave sustained cathode directed streamer propagation in helium flow channel with N{sub 2} annular co-flow compared to the streamer propagation in air or nitrogen have been shown to be caused by the remnant ionization distribution due to large differences in the dissociative recombination rates of He{sub 2}{sup +} versus N{sub 4}{sup +} ions, for this 5 kHz repetition rate applied voltage pulse generated streamers.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Cutaneous Microvascular Flow In the Foot During Simulated Variable Gravities

Our objective was to elucidate how varying gravitational fields affect blood perfusion in the sole of the foot. Human subjects underwent whole-body tilting at four angles: upright (1 G(sub z), 22 deg (.38 G(sub z)), 10 deg (.17 G(sub z)), and supine (0 G(sub z)), simulating the gravitational fields of Earth, Mars, Moon, and microgravity, respectively. Cutaneous capillary blood flow was monitored on the plantar surface of the heel by laser Doppler flowmetry while weight bearing load was measured beneath the same foot with a calibrated scale. Foot mean arterial pressures (MAP) were calculated by adding estimated hydrostatic pressures to continuously recorded heart-level blood pressures for each subject. At each tilt angle, subjects increased weight bearing on one foot in graded load increments of one kilogram beginning with zero. The weight bearing at which null flow first occurred was determined as the closing load (CL). Subsequently, the weight bearing was reduced in reverse steps until blood flow returned (opening load, OL). CL and OL were normalized to each subject's body weight and expressed as percent of body weight. Mean CLs (SD in parentheses) for simulated Earth, Mars, Moon, and micro-gravities were 14 (5), 8 (2), 6 (2), and 5 (2) percent of body weight, respectively. OLs were 12 (3), 6 (1), 5 (2), and 4 (1), respectively. Calculated foot MAPs for each simulated gravitational field were 192 (19), 127 (12), 106 (10), and 87 (9) mm Hg, respectively. CL and OL were significantly correlated with foot MAP (r = 0.70, 0.72, respectively). Overall, CL and OL were significantly different (p is less than 0.001). The data suggest that decreased local arterial pressure in the foot lowers tolerance to external compression. Consequently, the human foot sole may be more prone to cutaneous ischernia during loading in microgravity than on Earth.

Chang, David S.↗

Cutaneous microvascular flow in the foot during simulated variable gravities

Our objective was to understand how weight bearing with varying gravitational fields affects blood perfusion in the sole of the foot. Human subjects underwent whole body tilting at four angles: upright [1 gravitational vector from head to foot (Gz)], 22 degrees (0.38 Gz), 10 degrees (0.17 Gz), and supine (0 Gz), simulating the gravitational fields of Earth, Mars, Moon, and microgravity, respectively. Cutaneous capillary blood flow was monitored on the plantar surface of the heel by laser Doppler flowmetry while weight-bearing load was measured. At each tilt angle, subjects increased weight bearing on one foot in graded load increments of 1 kg beginning with zero. The weight bearing at which null flow first occurred was determined as the closing load. Subsequently, the weight bearing was reduced in reverse steps until blood flow returned (opening load). Mean closing loads for simulated Earth gravity, Mars gravity, Moon gravity, and microgravity were 9.1, 4.6, 4.4, and 3.6 kg, respectively. Mean opening loads were 7.9, 4.1, 3.5, and 3.1 kg, respectively. Mean arterial pressures in the foot (MAP(foot)) calculated for each simulated gravitational field were 192, 127, 106, and 87 mmHg, respectively. Closing load and opening load were significantly correlated with MAP(foot) (r =0.70, 0.72, respectively) and were significantly different (P < 0.001) from each other. The data suggest that decreased local arterial pressure in the foot lowers tolerance to external compression. Consequently, the human foot sole may be more prone to cutaneous ischemia during load bearing in microgravity than on Earth.

NASA Discipline Cardiopulmonary↗

Atomic-scale thermocapillary flow in focused ion beam milling

Focused ion beams provide a means of nanometer-scale manufacturing and material processing, which is used for applications such as forming nanometer-scale pores in thin films for DNA sequencing. We investigate such a configuration with Ga{sup +} bombardment of a Si thin-film target using molecular dynamics simulation. For a range of ion intensities in a realistic configuration, a recirculating melt region develops, which is seen to flow with a symmetrical pattern, counter to how it would flow were it driven by the ion momentum flux. Such flow is potentially important for the shape and composition of the formed structures. Relevant stress scales and estimated physical properties of silicon under these extreme conditions support the importance thermocapillary effects. A flow model with Marangoni forcing, based upon the temperature gradient and geometry from the atomistic simulation, indeed reproduces the flow and thus could be used to anticipate such flows and their influence in applications.

36 MATERIALS SCIENCE↗

Pore-scale flow characterization of low-interfacial tension flow through mixed-wet porous media with different pore geometries

The low-interfacial tension flow through porous media occurs in surfactant-based enhanced oil recovery (EOR), soil clean-up, underground removal of the non-aqueous phase liquid and dense non-aqueous phase liquid, etc. In surfactant-based EOR processes, numerous works have been carried out to characterize - either qualitatively or quantitatively - the micro- and macro-scale flow behavior. What has been lacking is to link the statistics of oil blobs population (e.g., distribution of blob length and diameter) to the pore-scale phenomena and macro-scale quantities. In particular, no work has been reported to elucidate the effect of the ratio of pore body to throat diameter (i.e., aspect ratio) on the pore-scale characterization based on the blobs population statistics. The significance of the aspect ratio lies in that it describes the geometry of a porous medium and is one of the foremost morphological features. The aspect ratio is also one of the fundamental factors governing the pore-level events. This study presents the effect of aspect ratio on the statistical distribution of the blob length and equivalent diameter and links the blobs population statistics to the observed pore-level events. The pore-scale variation of the ratio of viscous-to-capillary forces acted on the oil blobs at the threshold of displacement is utilized to characterize the effect of blob length distribution at different aspect ratios. It also provides some insight into correlating the change in oil recovery efficiency and capillary number, by change in aspect ratio, with the change in blobs population statistics. (author)

02 PETROLEUM↗

Self-generated electrokinetic flows from active-charged boundary patterns

We develop a hydrodynamic description of self-generated electrolyte flow in capillaries whose bounding walls feature nonuniform distributions of charge nonuniform active ionic fluxes. The hydrodynamic velocity arising in such a system has components that are forbidden by symmetry in the absence of charge and fluxes. However, when these two boundary mechanisms are simultaneously present, they can lead to a symmetry broken state where steady flows with both unidirectional and circulatory components emerge. We show that these flow states arise when modulated boundary patterns of charge and fluxes are offset by a flux-charge phase difference, which is associated with the separation between sites of their peak densities on the wall. Mismatch in diffusivity of cationic and anionic species can modify the flow states and becomes an enhancing factor when fluxes of both ion species are being produced together at the same site. We demonstrate that this mechanism can be realized with a microfluidic generator that is powered by enzyme-coated patches that catalyze reactants in the solution to produce fluxes of ions. The local ionic elevation or depletion, which disrupts a nonuniform double layer, promotes self-induced gradients yielding persistent body forces to generate bulk fluid motion. Our work quantifies a boundary-driven mechanism behind self-sustained electrolyte flow in confined environments that exists without any external bulk-imposed fields or gradients. It provides a theoretical framework for understanding the combined effect of active and charged boundaries that are relevant in biological or soft matter systems, and can be utilized in electrofluidic and iontronic applications.

active matter↗

Reconfigurable acquisition system with integrated optics for a portable flow cytometer

Portable and inexpensive scientific instruments that are capable of performing point of care diagnostics are needed for applications such as disease detection and diagnosis in resource-poor settings, for water quality and food supply monitoring, and for biosurveillance activities in autonomous vehicles. In this paper, we describe the development of a compact flow cytometer built from three separate, customizable, and interchangeable modules. The instrument as configured in this work is being developed specifically for the detection of selected Centers for Disease Control (CDC) category B biothreat agents through a bead-based assay: E. coli O157:H7, Salmonella, Listeria, and Shigella. It has two-color excitation, three-color fluorescence and light scattering detection, embedded electronics, and capillary based flow. However, these attributes can be easily modified for other applications such as cluster of differentiation 4 (CD4) counting. Proof of concept is demonstrated through a 6-plex bead assay with the results compared to a commercially available benchtop-sized instrument.

60 APPLIED LIFE SCIENCES↗

Active colloidal particles at fluid-fluid interfaces

Here this review explores the intersection between two important fields of colloid and interface science – that of active colloidal particles and of (passive) particles at fluid-fluid interfaces. The former uses energy input at the particle level to propel particle motions and direct dynamic assemblies. The latter relies on the spontaneous adsorption of particles at fluid interfaces to modify the interfacial energy, rheology, and permeability of biphasic materials. Here, we address two key questions that connect these otherwise distinct fields of study. How do liquid interfaces influence the dynamics of active or driven colloidal particles? How can particle activity influence the dynamics of liquid interfaces? These questions motivate the pursuit of active particle surfactants that move and organize at fluid interfaces to perform useful functions such as enhancing mass transport or modulating interfacial properties. Drawing examples from the literature, we discuss how fluid interfaces can provide a unique environment for the study of active colloids, how surface tension can be harnessed to propel particle motions, and how capillary interactions can be activated to achieve dynamically tunable emulsions and foams. We highlight opportunities for the future study and application of active particles at liquid interfaces.

42 ENGINEERING↗

Experimental studies of adiabatic flow boiling in fractal-like branching microchannels

Experimental results of adiabatic boiling of water flowing through a fractal-like branching microchannel network are presented and compared to numerical model simulations. The goal is to assess the ability of current pressure loss models applied to a bifurcating flow geometry. The fractal-like branching channel network is based on channel length and width ratios between adjacent branching levels of 2{sup -1/2}. There are four branching sections for a total flow length of 18 mm, a channel height of 150 {mu}m and a terminal channel width of 100 {mu}m. The channels were Deep Reactive Ion Etched (DRIE) into a silicon disk. A Pyrex disk was anodically bonded to the silicon to form the channel top to allow visualization of the flow within the channels. The flow rates ranged from 100 to 225 g/min and the inlet subcooling levels varied from 0.5 to 6 C. Pressure drop along the flow network and time averaged void fraction in each branching level were measured for each of the test conditions. The measured pressure drop ranged from 20 to 90 kPa, and the measured void fraction ranged from 0.3 to 0.9. The measured pressure drop results agree well with separated flow model predictions accounting for the varying flow geometry. The measured void fraction results followed the same trends as the model; however, the scatter in the experimental results is rather large. (author)

42 ENGINEERING↗

Pulmonary tissue volume, cardiac output, and diffusing capacity in sustained microgravity

In microgravity (microG) humans have marked changes in body fluids, with a combination of an overall fluid loss and a redistribution of fluids in the cranial direction. We investigated whether interstitial pulmonary edema develops as a result of a headward fluid shift or whether pulmonary tissue fluid volume is reduced as a result of the overall loss of body fluid. We measured pulmonary tissue volume (Vti), capillary blood flow, and diffusing capacity in four subjects before, during, and after 10 days of exposure to microG during spaceflight. Measurements were made by rebreathing a gas mixture containing small amounts of acetylene, carbon monoxide, and argon. Measurements made early in flight in two subjects showed no change in Vti despite large increases in stroke volume (40%) and diffusing capacity (13%) consistent with increased pulmonary capillary blood volume. Late in-flight measurements in four subjects showed a 25% reduction in Vti compared with preflight controls (P < 0.001). There was a concomittant reduction in stroke volume, to the extent that it was no longer significantly different from preflight control. Diffusing capacity remained elevated (11%; P < 0.05) late in flight. These findings suggest that, despite increased pulmonary perfusion and pulmonary capillary blood volume, interstitial pulmonary edema does not result from exposure to microG.

Clinical Trial↗