Search NASA⌕ Search

SEARCH · Search NASA

Results for “column separation”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 163 records · Page 9

Slotted quantum well sensor

Quantum-well sensors having an array of spatially separated quantum-well columns formed on a substrate. A grating can be formed increase the coupling efficiency.

Gunapala, Sarath D.↗

Single-Layer, All-Metal Patch Antenna Element with Wide Bandwidth

It is known that the impedance at the center of a patch antenna element is a short circuit, implying that a wire or post can be connected from the patch to the groundplane at this point without impacting radiation performance. In principle, this central post can be used to support the patch element, thus eliminating the need for dielectric. In spaceborne applications, this approach is problematic because a patch element supported by a single, thin post is highly susceptible to acoustic loads during launch. The technology reported here uses a large-diameter center post as its supporting structure. The supporting structure allows for the fabrication of a sufficiently rigid antenna element that can survive launch loads. The post may be either hollow or solid, depending on fabrication approach and/or mass constraints. The patch antenna element and support post are envisioned as being fabricated (milled) from a single piece of aluminum or other metal. Alternately, the patch plate and support column can be fabricated separately and then joined using fasteners, adhesive, or welding. Casting and electroforming are also viable techniques for manufacturing the metal patch part(s). The patch structure is then either bonded or fastened to the supporting groundplane. Arrays of patch elements can be fabricated by attaching several structures to a common groundplane/support structure.

Chamberlain, Neil F.↗

A Study of the Compressive Strength of Stiffened Plywood Panels

The results of compression tests on 44 stiffened plywood panels are presented and correlated in groups for the three types of failure observed: column failure, failure by separation of plywood from stiffener, and crushing failure. The expanded program of military aircraft construction has made it necessary to seek substitute materials that can be used in aircraft in place of aluminum alloys. Wood is one of these substitute materials. The development of synthetic resins as bonding and impregnating agents has resulted in the production of plywood which is being used in stressed-skin structures for aircraft. The use of plywood in such structures necessitates that tests be performed. to determine allowable stress values for use in design, This report presents a preliminary analysis of the results of compression tests on 44 stiffened plywood panels made by the Universal Moulded Products Corporation. The tests were made in a testing machine of 1,200,000 pounds capacity in the NACA structures research laboratory.

Lundquist, Eugene E.↗

Using High-Resolution Forward Model Simulations of Ideal Atmospheric Tracers to Assess the Spatial Information Content of Inverse CO2 Flux Estimates

Attribution of observed atmospheric carbon concentrations to emissions on the country, state or city level is often inferred using "inversion" techniques. Such computations are often performed using advanced mathematical techniques, such as synthesis inversion or four-dimensional variational analysis, that invoke tracing observed atmospheric concentrations backwards through a transport model to a source region. It is, to date, not well understood how well such techniques can represent fine spatial (and temporal) structure in the inverted flux fields. This question is addressed using forward-model computations with idealized tracers emitted at the surface in a large number of grid boxes over selected regions and examining how distinctly these emitted tracers can be detected downstream. Initial results show that tracers emitted in half-degree grid boxes over a large region of the Eastern USA cannot be distinguished from each other, even at short distances over the Atlantic Ocean, when they are emitted in grid boxes separated by less than five degrees of latitude - especially when only total-column observations are available. A large number of forward model simulations, with varying meteorological conditions, are used to assess how distinctly three types observations (total column, upper tropospheric column, and surface mixing ratio) can separate emissions from different sources. Inferences inverse modeling and source attribution will be drawn.

Pawson, Steven↗

A generalized distillation network synthesis model

In this report we propose a generalized superstructure-based distillation network synthesis model with improved modeling capabilities resulting in an extended solution space. The model can assign multiple mixtures to be separated (e.g., reactor network effluents) to different columns of the network while considering the interactions among different separation steps. In terms of outlets, products with general specifications, including pure components and multi-component mixtures, as well as streams without strict specifications (e.g., reactor recycle streams) can be readily handled. Furthermore, stream bypass is considered to avoid unnecessary separations, and thermal coupling is considered to yield novel solutions. The proposed model enables seamless integration with reactor network synthesis models thereby leading to solutions that are superior to the ones obtained by conventional sequential approaches.

42 ENGINEERING↗

Design and Performance of a Gas Chromatograph for Automatic Monitoring of Pollutants in Ambient Air

In recent years, interest in air pollution constituents has focused on carbon monoxide and hydrocarbons as prime components of polluted air. Instrumental methods have been developed, and commercial instruments for continuous monitoring of these components have been available for a number of years. For the measurement of carbon monoxide, non-dispersive infrared spectroscopy has been the accepted tool, in spite of its marginal sensitivity at low parts-per-million levels. For continuously monitoring total hydrocarbons, the hydrogen flame ionization analyzer has been widely accepted as the preferred method. The inadequacy of this latter method became evident when it was concluded that methane is non-reactive and cannot be considered a contaminant even though present at over 1 ppm in the earth's atmosphere. Hence, the need for measuring methane separately became apparent as a means of measuring the reactive and potentially harmful non-methane hydrocarbons fraction. A gas chromatographic method for the measurement of methane and total hydrocarbons which met these requirements has been developed. In this technique, methane was separated on conventional gas chromatographic columns and detected by a hydrogen flame ionization detector (FID) while the total hydrocarbons were obtained by introducing a second sample directly into the FID without separating the various components. The reactive, or non-methane hydrocarbons, were determined by difference. Carbon monoxide was also measured after converting to methane over a heated catalyst to render it detectable by the FID. The development of this method made it possible to perform these measurements with a sensitivity of as much as 1 ppm full scale and a minimum detectability of 20 ppb. Incorporating this technique, criteria were developed by APCO for a second generation continuous automatic instrument for atmospheric monitoring stations.

Villalobos, R.↗

Novel Method for Domestic Stable Isotope Production (CRADA #667) Final Report

This report presents the progress achieved on our chlorine isotope separation efforts in the CRADA #667 agreement. We used a microchannel distillation (MCD) packing structure to enrich HCl isotopes (H35Cl, H37Cl) and an isotachophoresis (ITP) separation to enrich ionic chloride species (35Cl- and 37Cl-). A 2 m tall MCD column was constructed and achieved 264 separation stages over several days, which is well above the goal of 50 stages outlined in the CRADA. The resulting height equivalent to a theoretical plate (HETP) was 0.76 cm. ITP tests were run ~ 24 hours and achieved a single-stage separation factor of 1.559.

07 ISOTOPE AND RADIATION SOURCES↗

A new method for the preparation of polymeric porous layer open tubular columns for GC application

A new method to prepare polymeric PLOT columns by using in situ polymerization technology is described. The method involves a straightforward in situ polymerization of the monomer. The polymer produced is directly coated on the metal tubing. This eliminates many of the steps needed in conventional polymeric PLOT column preparation. Our method is easy to operate and produces very reproducible columns, as shown previously (T. C. Shen. J. Chromatogr. Sci. 30, 239, 1992). The effects of solvents, tubing pretreatments, initiators and reaction temperatures in the preparation of PLOT columns are studied. Several columns have been developed to separate (1) highly polar compounds, such as water and ammonia or water and HCN, and (2) hydrocarbons and inert gases. A recent improvement has allowed us to produce bonded polymeric PLOT columns. These were studied, and the results are included also.

NASA Discipline Exobiology↗

Analysis of benzo(a)pyrene in airborne particulates by gas chromatography

A routine method was developed to measure benzo(a)pyrene in airborne particulates. Samples were collected on a filter and the organic portion was extracted with cyclohexane. The polynuclear hydrocarbon (PNHC) fraction was separated from the aliphatics by column chromatography. An internal standard was added to the extract and a portion of it was injected into a gas chromatograph. Although the gas chromatographic method has often been reported in the literature, satisfactory separation of benzo(a)pyrene and benzo(e)pyrene has not been achieved. With the introduction of a nematic liquid crystal as the stationary phase good separation is now possible.

Luedecke, E.↗

Gas Chromatograph Method Optimization Trade Study for RESOLVE: 20-meter Column v. 8-meter Column

RESOLVE is the payload on a Class D mission, Resource Prospector, which will prospect for water and other volatile resources at a lunar pole. The RESOLVE payload's primary scientific purpose includes determining the presence of water on the moon in the lunar regolith. In order to detect the water, a gas chromatograph (GC) will be used in conjunction with a mass spectrometer (MS). The goal of the experiment was to compare two GC column lengths and recommend which would be best for RESOLVE's purposes. Throughout the experiment, an Inficon Fusion GC and an Inficon Micro GC 3000 were used. The Fusion had a 20m long column with 0.25mm internal diameter (Id). The Micro GC 3000 had an 8m long column with a 0.32mm Id. By varying the column temperature and column pressure while holding all other parameters constant, the ideal conditions for testing with each column length in their individual instrument configurations were determined. The criteria used for determining the optimal method parameters included (in no particular order) (1) quickest run time, (2) peak sharpness, and (3) peak separation. After testing numerous combinations of temperature and pressure, the parameters for each column length that resulted in the most optimal data given my three criteria were selected. The ideal temperature and pressure for the 20m column were 95 C and 50psig. At this temperature and pressure, the peaks were separated and the retention times were shorter compared to other combinations. The Inficon Micro GC 3000 operated better at lower temperature mainly due to the shorter 8m column. The optimal column temperature and pressure were 70 C and 30psig. The Inficon Micro GC 3000 8m column had worse separation than the Inficon Fusion 20m column, but was able to separate water within a shorter run time. Therefore, the most significant tradeoff between the two column lengths was peak separation of the sample versus run time. After performing several tests, it was concluded that better detection via good peak separation with a longer run time is a better asset than moderate peak separation with a shorter run time. Even given that RESOLVE is highly interested in water and that mission timeline is of significant importance given the short seven-to-ten-day mission timeline, worse detection with an 8m column may lead to overlooking other substances existing on the moon that could advance planetary science. Thus, I recommend the 20m column. However, if mission timeline and water separation are deemed the highest priority, the 8m column should be selected due to its ability to separate water within a shorter run time than the 20m column.

Column↗

Novel Method for Domestic Stable Isotope Production

This report presents the progress achieved on our chlorine isotope separation efforts in the CRADA #667 agreement. We used a microchannel distillation (MCD) packing structure to enrich HCl isotopes (H35Cl, H37Cl) and an isotachophoresis (ITP) separation to enrich ionic chloride species ( 35 Cl- and 37 Cl-). A 2 m tall MCD column was constructed and achieved 264 separation stages over several days, which is well above the goal of 50 stages outlined in the CRADA. The resulting height equivalent to a theoretical plate (HETP) was 0.76 cm. ITP tests were run ~ 24 hours and achieved a single-stage separation factor of 1.559.

07 ISOTOPE AND RADIATION SOURCES↗

Flexible Zn-MOF with Rare Underlying scu Topology for Effective Separation of C6 Alkane Isomers

Adsorptive separation by porous solids provides an energy-efficient alternative for the purification of important chemical species compared to energy-intensive distillations. Particularly, the separation of linear hexane isomers from its branched counterparts is crucial to produce premium grade gasoline with high research octane number (RON). Herein, we report the synthesis of a new, flexible zinc-based metal-organic framework, [Zn 5 (μ 3 -OH) 2 (adtb) 2 (H 2 O) 5 ·5 DMA] (Zn-adtb), constructed from a butterfly shaped carboxylate linker with underlying (4,8)-connected scu topology capable of separating the C6 isomers nHEX, 3MP, and 23DMB. The sorbate-sorbent interactions and separation mechanisms were investigated and analyzed through in situ FTIR, solid state NMR measurements and computational modeling. Here these studies reveal that Zn-adtb discriminates the nHEX/3MP isomer pair through a kinetic separation mechanism and the nHEX/23DMB isomer pair through a molecular sieving mechanism. Column breakthrough measurements further demonstrate the efficient separation of linear nHEX from the mono- and dibranched isomers.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Production, isolation, and shipment of clinically relevant quantities of astatine-211: A simple and efficient approach to increasing supply

The alpha emitter astatine-211 ( 211 At) is a promising candidate for cancer treatment based on Targeted Alpha (α) Therapy (TAT). A small number of facilities, distributed across the United States, are capable of accelerating α-particle beams to produce 211 At. However, challenges remain regarding strategic methods for shipping 211 At in a form adaptable to advanced radiochemistry reactions and other uses of the radioisotope. Purpose: Our method allows shipment of 211 At in various quantities in a form convenient for further radiochemistry. Procedures: For this study, a 3-octanone impregnated Amberchrom® CG300M resin bed in a column cartridge was used to separate 211 At from the bismuth matrix on site at the production accelerator (Texas A&M) in preparation for shipping. Aliquots of 6 M HNO 3 containing up to ≈2.22 GBq of 211 At from the dissolved target were successfully loaded and retained on columns. Exempt packages (<370 MBq) were shipped to a destination radiochemistry facility, University of Texas MD Anderson Cancer Center, in the form of a convenient air-dried column. Type A packages have been shipped overnight to University of Alabama at Birmingham. Main findings: Air-dried column hold times of various lengths did not inhibit simple and efficient recovery of 211 At. Solution eluted from the column was sufficiently high in specific activity to successfully radiolabel a model compound, 4-(4,4,5,5-tetramethyl-1,3,2-dioxaborolan-2-yl)aniline (1), with 211 At. The method to prepare and ship 211 At described in this manuscript has also been used to ship larger quantities of 211 At a greater distance to University of Alabama at Birmingham. Principal conclusions: The successful proof of this method paves the way for the distribution of 211 At from Texas A&M University to research institutions and clinical oncology centers in Texas and elsewhere. Finally, use of this simple method at other facilities has the potential increase the overall availability of 211 At for preclinical and clinical studies.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

OC6 Phase Ib: Validation of the CFD predictions of difference-frequency wave excitation on a FOWT semisubmersible

During the previous OC5 11 project, state-of-the-art mid-fidelity engineering tools for floating wind systems were found to consistently underpredict the nonlinear, low-frequency responses of semisubmersible offshore wind platforms, leading to substantial errors in the structural loads because of low-frequency surge and pitch resonance. To examine this underprediction, a coordinated investigation with computational fluid dynamics (CFD) simulations and model-basin experiments was carried out. Both investigations involved a fixed and simplified OC5-DeepCwind semisubmersible in bichromatic waves. The wave excitations - especially the nonlinear, difference-frequency excitation - on the structure from the CFD simulations were compared to the experimental measurements for validation, with uncertainty analyses for both the experimental and the CFD results. Furthermore, the wave excitations on each column of the semisubmersible were measured separately in the experiment, allowing the validation of the CFD results to be done on a per-column basis. Overall, the CFD predictions of the difference-frequency excitations agree with the experimental measurements, suggesting the CFD solutions can be used as a reference for tuning and improving the engineering-level tools and can provide a means to better understand the underprediction at low frequencies.

16 TIDAL AND WAVE POWER↗

Rapid and automated separation of uranium ore concentrates for trace element analysis by inductively coupled plasma – optical emission spectroscopy/triple quadrupole mass spectrometry

The present study documents an automated approach to performing elemental analysis on a large group uranium ore concentrate (UOC) samples. In this work, 17 UOC samples, 2 quality control samples, and 26 process blanks were purified sequentially through a single 500 μL Uranium and TEtra Valent Actinides (UTEVA®) column. For each sample, the trace elemental impurities were separated from its dissolved uranium matrix on the UTEVA column and collected for analysis by inductively coupled plasma – optical emission spectroscopy / triple quadrupole mass spectrometry (ICP-OES/TQMS). The UTEVA column was subsequently regenerated prior to separation of the following sample. The column was efficiently regenerated, for each UOC, even after processing ~50 mg of uranium, cumulatively. The validity of the method was established by determining the trace impurities of two quality control uranium reference samples (CRM 124–1 and CUP-2). The current trace element measurements from the 17 UOC samples were compared to previously reported values from an interlaboratory comparison exercise, when available. The methodology employed here produces trace elemental analysis with excellent correlation to the previously reported data for many of the elements / samples, particularly when viewed through the context of existing geochemical comparisons tools (e.g. chondrite normalized variation plots).

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Preparative liquid column electrophoresis of T and B lymphocytes at gravity = 1

Vertical liquid columns containing low-molecular-weight dextran density gradients can be used for preparative lymphocyte electrophoresis on earth, in simulation of zero gravity conditions. Another method that has been tested at 1 g, is the electrophoresis of lymphocytes in an upward direction in vertical columns. By both methods up to 100 million lymphocytes can be separated at one time in a 30-cm glass column of 8-mm inside diameter, at 12 V/cm, in two hours. Due to convection and sedimentation problems, the separation at 1 g is less than ideal, but it is expected that at zero gravity electrophoresis will probe to be a uniquely powerful cell separation tool.

Van Oss, C. J.↗

Retinoid quantification by HPLC/MS(n)

Retinoic acid (RA) mediates most of the biological effects of vitamin A that are essential for vertebrate survival. It acts through binding to receptors that belong to the nuclear receptor transcription factor superfamily (Mangelsdorf et al. 1994). It is also a highly potent vertebrate teratogen. To determine the function and effects of endogenous and exogenous RA, it is important to have a highly specific, sensitive, accurate, and precise analytical procedure. Current analyses of RA and other retinoids are labor intensive, of poor sensitivity, have limited specificity, or require compatibility with RA reporter cell lines (Chen et al. 1995. BIOCHEM: Pharmacol. 50: 1257-1264; Creech Kraft et al. 1994. BIOCHEM: J. 301: 111-119; Lanvers et al. 1996. J. Chromatogr. B Biomed. Appl. 685: 233-240; Maden et al. 1998. DEVELOPMENT: 125: 4133-4144; Wagner et al. 1992. DEVELOPMENT: 116: 55-66). This paper describes an HPLC/mass spectrometry/mass spectrometry product ion scan (HPLC/MS(n)) procedure for the analysis of retinoids that employs atmospheric pressure chemical ionization MS. The retinoids are separated by normal-phase column chromatography with a linear hexane-isopropanol-dioxane gradient. Each retinoid is detected by a unique series of MS(n) functions set at optimal collision-induced dissociation energy (30% to 32%) for all MS(n) steps. The scan events are divided into three segments, based on HPLC elution order, to maximize the mass spectrometer duty cycle. The all-trans, 9-cis, and 13-cis RA isomers are separated, if desired, by an isocratic hexane-dioxane-isopropanol mobile phase. This paper describes an HPLC/MS(n) procedure possessing high sensitivity and specificity for retinoids.

NASA Discipline Developmental Biology↗