Search NASA⌕ Search

SEARCH · Search NASA

Results for “compute tomography”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 163 records · Page 9

Livermore Computed Tomography Input/Output library

Read, write, and connect visualizers to data for LLNL radiography and CT tools (e.g. LTT: https://softwarelicensing.llnl.gov/product/livermore-tomography-tools-ltt).

Vardar-Irrgang, MichaelE [Lawrence Livermore Natio↗

Using multimodal X-ray computed tomography to advance 3D petrography: A non-destructive investigation of olivine inside a carbonaceous chondrite

Rocks form in three dimensions through time and studying them provides information from inside dynamic systems we cannot otherwise observe. Yet how we typically access the interior of the rocks themselves to gain that information may limit our understanding and influence how we reconstruct the processes that formed them. Here, we demonstrate combined non-destructive 3D X-ray imaging techniques that produce quantitative densitometric and crystallographic maps of entire individual grains inside a rock. Olivine grains throughout a sample of the carbonaceous chondrite Northwest Africa (NWA) 11346 were each characterized by size, shape, composition, zoning intensity, and crystallographic orientation. The addition of 3D crystallographic mapping to calibrated 3D densitometric analysis—used to calculate chemical composition—demonstrates a fully non-destructive petrographic method and provides unique insight. For instance, in our case, using crystallographic data to delineate individual grains and then measuring the 3D size, shape, and composition of each distinguishes variably reset relict grains from those later crystallized after a melting event. Intersection in a 2D slice could not have led to this interpretation because the integration of three-dimensional size, rounding, composition, location, and crystallographic orientation measured from each grain forms the key patterns. Multimodal laboratory X-ray imaging has strong potential to advance 3D petrography.

36 MATERIALS SCIENCE↗

Leveraging Afterglow in Scintillation-based x-ray detectors for spacetime-resolved computed tomography for accelerated acquisition and high-speed event capture

Afterglow in x-ray imaging for high-speed radiography is a constraint that limits imaging systems to low-light/fast decay screens which create poor data. Current approaches focus purely on using low-light yield screens with fast decay to avoid multiple exposure pileup due to afterglow. The goal of this work is to develop a statistical estimation approach to leverage afterglow to improve image quality thus allowing for higher quality imaging components to be used. This will allow for bright screens will slow decay to be used, and then a post-processing step applies the statistical estimation to separate each frame with superior signal compared to low-light/fast decay screens.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Design criteria and eigensequence plots for satellite computed tomography

The use of the degrees of freedom for signal is proposed as a design criteria for comparing different designs for satellite and other measuring systems. It is also proposed that certain eigensequence plots be examined at the design stage along with appropriate estimates of the parameter lambda playing the role of noise to signal ratio. The degrees of freedom for signal and the eigensequence plots may be determined using prior information in the spectral domain which is presently available along with a description of the system, and simulated data for estimating lambda. This work extends the 1972 work of Weinreb and Crosby.

Wahba, G.↗

Design criteria and eigensequence plots for satellite-computed tomography

The use of the degrees of freedom for signal is proposed as a design criteria for comparing different designs for satellite and other measuring systems. It is also proposed that certain eigensequence plots be examined at the design stage along with appropriate estimates of the parameter lambda playing the role of noise to signal ratio. The degrees of freedom for signal and the eigensequence plots may be determined using prior information in the spectral domain which is presently available along with a description of the system, and simulated data for estimating lambda. This work extends the 1972 work of Weinreb and Crosby.

Wahba, G.↗

Serial Scanning and Registration of High Resolution Quantitative Computed Tomography Volume Scans for the Determination of Local Bone Density Changes

Progress in development of the methods required to study bone remodeling as a function of time is reported. The following topics are presented: 'A New Methodology for Registration Accuracy Evaluation', 'Registration of Serial Skeletal Images for Accurately Measuring Changes in Bone Density', and 'Precise and Accurate Gold Standard for Multimodality and Serial Registration Method Evaluations.'

Whalen, Robert T.↗

Uses of Computed Tomography for Characterizing Materials Grown Terrestrially and in Microgravity

Tomography (CT) has proved to be of inestimable use in providing a rapid evaluation of a variety of samples from Mechanics of Granular Materials (MGM) to electronic materials (Ge-Si alloys) to space grown materials such as meteorites. The system at Kennedy Space Center (KSC), because of its convenient geographical location, is ideal for examining samples before launch and immediately after returning to Earth. It also has the advantage of the choice of fluxes, and in particular the use of a radioactive cobalt source, which is basically monochromatic. This permits a reasonable measurement of density to be made from which chemical composition can be determined. Due to the current dearth of long duration space grown materials, the CT instrument has been used: (1) to characterize materials in preparation for flight, (2) to determine thermal expansion values, and (3) to examine long duration space grown materials, i.e. meteorites. This work will first describe the establishment of the protocol for obtaining the optimum density readings for any material. Included will be the effects of the hardware or instrumental parameters that can be controlled, and the techniques used to process the CT data. Examples will be given of the compositional variation along a single crystal of Ge-Si alloy. Density variation with temperature has been measured in preparation for future materials science experiments; this involved the fabrication at MSFC and installation of a single zone furnace at KSC incorporating a heat pipe to ensure high temperature uniformity. At the time of writing the thermal expansion of lead (Pb) has been measured from room temperature to 900 C. Three methods are available. Digital radiography enables length changes to be determined. Prior to melting the sample is smaller than the container and the diameter change can be measured. Most critical, however, is the density change in solid, through the melting region, and in the liquid state. These data are needed for engineering purposes to aid in the design of containment cartridges, and for enabling fluid flow calculations. A second sample, with the Pb alloyed with Sb is ready for scanning. This corresponds to the planned composition of Dr. Poirier s flight experiment. Other materials pertinent to NASA programs such as Al-Cu (Trivedi), CdTe (Banish), HgCdTe (Lehoczky) will be examined below and above the melting point. Finally, three-dimensional results will be shown of the structure of a two-phase metallic meteorite of metal and sulfide, in which the Fe-Ni phase has coarsened during slow cooling over hundreds of millions of years.

Source record↗

Quantitative computed tomography for spinal mineral assessment: current status

Quantitative CT (QCT) is an established method for the noninvasive assessment of bone mineral content in the vertebral spongiosum and other anatomic locations. The potential strengths of QCT relative to dual photon absorptiometry (DPA) are its capability for precise three-dimensional anatomic localization providing a direct density measurement and its capability for spatial separation of highly responsive cancellous bone from less responsive cortical bone. The extraction of this quantitative information from the CT image, however, requires sophisticated calibration and positioning techniques and careful technical monitoring.

Lumbar Vertebrae/radiography↗

Applications of Computed Tomography to Evaluate Cellular Solid Interfaces

The major morphological features - foam cells, voids, knit lines, and the bondline interface were evaluated. The features identified by micro-CT correlate well to those observed by SEM. 3D reconstructions yielded volumetric dimensions for large voids (max ~ 30 mm). Internal voids and groupings of smaller cells at the bondline are concluded to be the cause of the indications noted during the NDE prescreening process.

Maisano, Josephine↗

The Astromaterials X-Ray Computed Tomography Laboratory at Johnson Space Center

The Astromaterials Acquisition and Cura-tion Office at NASA's Johnson Space Center (hereafter JSC curation) is the past, present, and future home of all of NASA's astromaterials sample collections. JSC curation currently houses all or part of nine different sample collections. Our primary goals are to maintain the long-term integrity of the samples and ensure that the samples are distributed for scientific study in a fair, timely, and responsible manner, thus maximizing the return on each sample. Part of the curation process is planning for the future, thus we also perform funda-mental research in advanced curation initiatives. Ad-vanced Curation is tasked with developing procedures, technology, and data sets necessary for curating new types of sample collections, or getting new results from existing sample collections [1]. As part of these ad-vanced curation efforts we are augmenting our analyti-cal facilities.

Zeigler, R. A.↗