At least 163 records · Page 9

Experimental evaluation of a breadboard heat and product-water removal system for a space-power fuel cell designed with static water removal and evaporative cooling

A test program was conducted to evaluate the design of a heat and product-water removal system to be used with fuel cell having static water removal and evaporative cooling. The program, which was conducted on a breadboard version of the system, provided a general assessment of the design in terms of operational integrity and transient stability. This assessment showed that, on the whole, the concept appears to be inherently sound but that in refining this design, several facets will require additional study. These involve interactions between pressure regulators in the pumping loop that occur when they are not correctly matched and the question of whether an ejector is necessary in the system.

Hagedorn, N. H.↗

Exploratory Investigation of Transpiration Cooling of a 40 Degree Double Wedge Using Nitrogen and Helium as Coolants at Stagnation Temperatures from 1,295 Degrees Fahrenheit to 2,910 Degrees Fahrenheit

An investigation of transpiration cooling has been conducted in the preflight jet of the Langley Pilotless Aircraft Research Station at Wallops Island, Va. The model consisted of a double wedge of 40 deg included angle having a porous stainless-steel specimen inserted flush with the top surface of the wedge. The tests were conducted at a free-stream Mach number of 2.0 for stagnation temperatures ranging from 1,295 F to 2,910 F. Nitrogen and helium were used as coolants and tests were conducted for values ranging from approximately 0.03 to 0.30 percent of the local weight flow rate. The data for both the nitrogen and helium coolants indicated greater cooling effectiveness than that predicted by theory and were in good agreement with the results for an 8 deg cone tested at a stagnation temperature of 600 F. The results indicate that the helium coolant, for the same amount of heat-transfer reduction, requires only about one-fourth to one-fifth the coolant flow weight as the nitrogen coolant.

Rashis, Bernard↗

The heating of a thermally conducting stratified medium. II - A simple plane model of an atmosphere

Exact solutions of the following theoretical problem are presented: A plane atmosphere is in hydrostatic equilibrium with a uniform gravity. The ideal gas law is assumed. Heat is generated everywhere at a rate proportional to the local density. The atmosphere is maintained in a steady state through cooling by thermal conduction and radiation. This problem is reducible to quadratures for a thermal conductivity which is an arbitrary, but prescribed, function of the temperature, and for a radiative loss which is expressible as the product of the density and an arbitrary, but prescribed, function of the pressure. The analysis is carried out for the case of power law thermal conductivity, and a radiative loss proportional to the square of the density and to the first power of the temperature. The radiative cooling function adopted here has the basic mathematical form for an optically thin medium. The solutions reproduce the macroscopic ordering of a hot 'corona' separated from a 'photosphere' by a layer of temperature minimum. The analytic solutions allow direct illustration of the interplay between steady energy transport and the requirements of hydrostatic equilibrium.

Lerche, I.↗

Temperature distribution study in a cooled radial inflow turbine rotor

A numerical study to determine the temperature distribution in the rotor of a radial inflow turbine is presented. The study is based on the use of the finite element method in the three dimensional heat conduction problem. Different cooling techniques with various coolant to primary mass flow ratios are investigated. The resulting temperature distribution in the rotor are presented for comparison.

Hamed, A.↗

Reliability and effective thermal conductivity of three metallic-ceramic composite insulating coatings on cooled hydrogen-oxygen rockets

An experimental investigation of the structural integrity and effective thermal conductivity of three metallic-ceramic composite coatings was conducted. These coatings were plasma sprayed onto the combustion side of water-cooled, 12.7-centimeter throat diameter, hydrogen-oxygen rocket thrust chambers operating at 2.07 to 4.14 meganewtons per square meter chamber pressure. The metallic-ceramic composites functioned for six to 17 cycles and for as long as 213 seconds of rocket operations and could have probably provided their insulating properties for many additional cycles. The effective thermal conductivity of all the coatings was in the range of 0.7472 to 4.483 w/(m)(K), which makes the coatings a very effective thermal barrier. Photomicrographic studies of cross-sectioned coolant tubes seem to indicate that the effective thermal conductivity of the coatings is controlled by contact resistance between the particles, as a result of the spraying process, and not the thermal conductivity of the bulk materials.

Price, H. G., Jr.↗

CAE for thermal management of aerospace electronic boards using the BETAsoft program

Aerospace electronic boards require special attention to thermal management due to constraints such as their need to be light, small, and maintain high power densities. Also, cooling is mainly through conductive and radiative modes with minor or negligible convective cooling. Due to these particular requirements, thermal design has become an integrated part of the electronic design process in order to avoid expensive repeat prototyping and to ensure high reliability. To achieve high speed simulations, the BETAsoft code uses semi-empirical formulations and an advanced finite difference scheme that incorporates local adaptive grids. Detailed conduction, convection and radiation heat transfer is considered. Various benchmark verifications of the software simulation compared to infrared images typically prove to be within 10% of each other. The thermal analysis of a sample avionic card in a natural convection environment is shown. Then, the individual effects of attaching metal screws to the casing, increasing radiative emissivities of the casing, increasing the conductance of the wedge lock, adding an aluminum core to the board, adding metal strips in board layers, inserting conduction pads under components, and adding heat sinks to components are demonstrated.

Bobish, Kimberly↗

Radiative cooling in shock-heated hydrogen-helium plasmas

Axial and off-axis radiative cooling of cylindrical shock-heated hydrogen-helium plasmas is investigated theoretically and experimentally. The coupled fluid dynamic-radiative transfer equations are solved by a combination of approximation techniques aimed at simplifying the computation of the flux divergence term, namely, the quasi-isothermal approximation and the exponential approximation developed for the solid angle integration. The accuracy of the approximation schemes has been assessed and found acceptable for applying the methods to the rapid computation of the radiatively coupled flow problem. Radiative cooling experiments were conducted in a 6-inch annular arc accelerator shock tube (ANAA) for an initial pressure of 1 torr and shock speeds from 35 to 45 Km/sec. The results indicate that the lateral cooling is small compared with the axial cooling, and that better agreement is achieved between the data and the theoretical results by inclusion of the lateral temperature gradient.

Poon, P. T. Y.↗

Metal temperatures and coolant flow in a wire cloth transpiration cooled turbine vane

An experimental heat transfer investigation was conducted on an air-cooled turbine vane made from wire-wound cloth material and supported by a central strut. Vane temperature data obtained are compared with temperature data from two full-coverage film-cooled vanes made of different laminated construction. Measured porous-airfoil temperatures are compared with predicted temperatures.

Gladden, H. J.↗

Impact of Cubic Pin Finned Surface Structure Geometry upon Spray Cooling Heat Transfer

Experiments were conducted to study the effects of enhanced surface structures on heat flux using spray cooling. The surface enhancements consisted of cubic pin fins machined on the top surface of copper heater blocks. The structure height, pitch, and width were parametrically vaned. Each copper block had a projected cross-sectional area of 2.0 sq cm. Measurements were also obtained on a heater block with a flat surface for baseline comparison purposes. A 2 x 2 nozzle array was used with PF-5060 as the working fluid. Thermal performance data were obtained under nominally degassed (chamber pressure of 41.4 kPa) and gassy conditions (chamber with N2 gas at 100.7 kPa) with a bulk fluid temperature of 20.5 C. Results for both the degassed and gassy cases show that structure width and separation distance have a dominant effect upon the heat transfer for the size ranges used. Cubic pin fin height had little impact upon heat flux. The maximum critical heat flux (CHF) attained for any of the surfaces was 121 W/sq cm, giving an enhancement of 51% relative to the flat surface case under nominally degassed conditions. The gassy case had a maximum CHF of 149 W/sq cm, giving an enhancement of 38% relative to the flat surface case.

Silk, Eric A.↗

Stagnation region gas film cooling: Effects of dimensionless coolant temperature

An experimental investigation was conducted to mode the film cooling performance for a turbine vane leading edge using the stagnation region of a cylinder in cross flow. Experiments were conducted with a single row of spanwise angled (25 deg) coolant holes for a range of the coolant blowing ratio and dimensionless coolant temperature with free stream-to-wall temperature ratio approximately 1.7 and Re sub D = 90000. the cylindrical test surface was instrumented with miniature heat flux gages and wall thermocouples to determine the percentage reduction in the Stanton number as a function of the distance downstream from injection (x/d sub 0) and the location between adjacent holes (z/S). Data from local heat flux measurements are presented for injection from a single row located at 5 deg, 22.9 deg, 40.8 deg, from stagnation using a hole spacing ratio of S/d = 5. The film coolant was injected with T sub c T sub w with a dimensionless coolant temperature in the range 1.18 or equal to theta sub c or equal to 1.56. The data for local Stanton Number Reduction (SNR) showed a significant increase in SNR as theta sub c was increased above 1.0.

Bonnice, M. A.↗

Cooling of Gas Turbines I - Effects of Addition of Fins to Blade Tips and Rotor, Admission of Cooling Air Through Part of Nozzles, and Change in Thermal Conductivity of Turbine Components

An analysis was developed for calculating the radial temperature distribution in a gas turbine with only the temperatures of the gas and the cooling air and the surface heat-transfer coefficient known. This analysis was applied to determine the temperatures of a complete wheel of a conventional single-stage impulse exhaust-gas turbine. The temperatures were first calculated for the case of the turbine operating at design conditions of speed, gas flow, etc. and with only the customary cooling arising from exposure of the outer blade flange and one face of the rotor to the air. Calculations were next made for the case of fins applied to the outer blade flange and the rotor. Finally the effects of using part of the nozzles (from 0 to 40 percent) for supplying cooling air and the effects of varying the metal thermal conductivity from 12 to 260 Btu per hour per foot per degree Farenheit on the wheel temperatures were determined. The gas temperatures at the nozzle box used in the calculations ranged from 1600F to 2000F. The results showed that if more than a few hundred degrees of cooling of turbine blades are required other means than indirect cooling with fins on the rotor and outer blade flange would be necessary. The amount of cooling indicated for the type of finning used could produce some improvement in efficiency and a large increase in durability of the wheel. The results also showed that if a large difference is to exist between the effective temperature of the exhaust gas and that of the blade material, as must be the case with present turbine materials and the high exhaust-gas temperatures desired (2000F and above), two alternatives are suggested: (a) If metal with a thermal conductivity comparable with copper is used, then the blade temperature can be reduced by strong cooling at both the blade tip and root. The center of the blade will be less than 2000F hotter than the ends; (b) With low conductivity materials some method of direct cooling other than partial admission of cooling air is essential. From this study, it can be deduced that indirect cooling of turbine blades will not make possible large increases in gas temperature.

Brown, Byron↗

Reduced Boil-Off System Sizing

NASA is currently developing cryogenic propellant storage and transfer systems for future space exploration and scientific discovery missions by addressing the need to raise the technology readiness level of cryogenic fluid management technologies. Cryogenic propellants are baselined in many propulsion systems due to their inherently high specific impulse; however, their low boiling points can cause substantial boil-off losses over time. Recent efforts such as the Reduced Boil-off Testing and the Active Thermal Control Scaling Study provide important information on the benefit of an active cooling system applied to LH2 propellant storage. Findings show that zero-boil off technologies can reduce overall mass in LH2 storage systems when low Earth orbit loiter periods extend beyond two months. A significant part of this mass reduction is realized by integrating two stages of cooling: a 20 K stage to intercept heat at the tank surface, and a 90 K stage to reduce the heat entering the less efficient 20 K stage. A missing element in previous studies, which is addressed in this paper, is the development of a direct method for sizing the 90 K cooling stage. Such a method requires calculation of the heat entering both the 90 K and 20 K stages as compared to the overall system masses, and is reliant upon the temperature distribution, performance, and unique design characteristics of the system in question. By utilizing the known conductance of a system without active thermal control, the heat being intercepted by a 90 K stage can be calculated to find the resultant lift and mass of each active thermal control stage. Integral to this is the thermal conductance of the cooling straps and the broad area cooling shield, key parts of the 90 K stage. Additionally, a trade study is performed to show the ability of the 90 K cooling stage to reduce the lift on the 20 K cryocooler stage, which is considerably less developed and efficient than 90 K cryocoolers.

Cryogenic fluid management↗

Evaluation of scramjet nozzle configurations and film cooling for reduction of wall heating

Experiments on relaminarization, or reverse transition of turbulent flow, have been conducted with a scramjet combustor and nozzle model. The Mach-2.7 direct-connect scramjet combustor employed swept-ramp fuel injectors, and the entering flow simulated Mach-6 to Mach-7 flight conditions. Tests were also conducted without combustor fuel to produce a higher nozzle entrance Mach number and lower pressures. Additional tests were conducted to evaluate the effectiveness of film cooling on the cowl region. At each test condition studied, the entrance radius had no significant effect on the measured downstream wall heating rates. Analysis of the data when fuel was injected into the combustor shows good agreement with turbulent theory; for the tests without fuel injection and combustion, the data downstream of the nozzle entrance radius are intermediate to the calculated turbulent and laminar solutions. Results of film-cooling tests, conducted with both hydrogen and nitrogen injectants, showed that, per unit mass, the hydrogen was approximately three to four times more effective than nitrogen in reducing the downstream wall heating rates.

Baker, N. R.↗

FUSE Observations of O VI Absorption in the Local Interstellar Medium

We report the results of an initial Far Ultraviolet Spectroscopic Explorer (FUSE) survey of O VI Lambda 1032 absorption along the lines of sight to eleven nearby white dwarfs, ten of which are within the Local Bubble (LB; d < or approximately equal 100 pc). A goal of this survey is to investigate the possible formation of O VI in the conductive interfaces between cool (about 10(exp 4) K) clouds immersed in the presumably hot (10(exp 6) K) gas within the LB. This mechanism is often invoked to explain the widespread presence of 0 VI throughout the Galactic disk. We find no 0 VI absorption toward two stars, and the column densities along three additional sight lines are quite low; N(O VI) about 5 x 10(exp 13)/sq cm. In several directions, we observe rather broad, shallow absorption with N(O VI) about 1 - 2 x 10(exp 13)/sq cm. Models of conductive interfaces predict narrow profiles with N(OVI) > or about equal to 10(exp 13)/sq cm per interface, in the absence of a significant transverse magnetic field. Hence, our observations of weak 0 VI absorption indicate that conduction is being quenched, possibly by non-radial magnetic fields. Alternatively, the gas within the LB may not be hot. Breitschwerdt & Schmutzler have proposed a model for the LB in which an explosive event within a dense cloud created rapid expansion and adiabatic cooling, resulting in a cavity containing gas with a kinetic temperature of T about 50,000 K, but with an ionization state characteristic of much hotter gas. This model has a number of attractive features, but appears to predict significantly more O VI than we observe.

Oegerle, W. R.↗

Turbine vane leading edge gas film cooling with spanwise angled coolant holes

An experimental film cooling study was conducted on a 3x size model turbine vane. Injection at the leading edge was from a single row of holes angled in a spanwise direction for two configurations of holes at 18 or 35 deg to the surface. The reduction in the local Stanton number for injection at a coolant-to-mainstream density ratio of 2.18 was calculated from heat flux measurements downstream of injection. Results indicate that optimum cooling occurs near a coolant-to-mainstream velocity ratio of 0.5. Shallow injection angles appear to be most beneficial when injecting into a highly accelerated mainstream.

Hanus, G. J.↗

Design of a Microgravity Spray Cooling Experiment

An analytical and experimental study was conducted for the application of spray cooling in a microgravity and high-g environment. Experiments were carried out aboard the NASA KC-135 reduced gravity aircraft, which provided the microgravity and high-g environments. In reduced gravity, surface tension flow was observed around the spray nozzle, due to unconstrained liquid in the test chamber and flow reversal at the heat source. A transient analytical model was developed to predict the temperature and the spray heat transfer coefficient within the heated region. Comparison of the experimental transient temperature variation with analytical results showed good agreement for low heat input values. The transient analysis also verified that thermal equilibrium within the heated region could be reached during the 20-25s reduced gravity portion of the flight profile.

Baysinger, Kerri M.↗

Evaporative cooling of flare plasma

We investigate a one-dimensional loop model for the evaporative cooling of the coronal flare plasma. The important assumptions are that conductive losses dominate radiative cooling and that the evaporative velocities are small compared with the sound speed. We calculate the profile and evolution of the temperature and verify the accuracy of our assumptions for plasma parameters typical of flare regions. The model is in agreement with soft X-ray observations on the evolution of flare temperatures and emission measures. The effect of evaporation is to greatly reduce the conductive heat flux into the chromosphere and to enhance the EUV emission from the coronal flare plasma.