Fermilab's Horizontal Test Stand Upgrade Overview and Commissioning

Cryo-assemblies with the Nb 3 Sn MQXFA low-beta quadrupoles for the High Luminosity LHC (HL-LHC) upgrade will be tested at Fermilab's magnet test facility. A total of 10 cryo-assemblies will be delivered to CERN within the US HL-LHC Accelerator Upgrade Project (AUP). The horizontal test stand at Fermilab already has been used for testing the existing LHC inner-triplet quadrupoles, but the stand and corresponding electrical and cryogenic sub-systems were not operational for more than a decade. In order to restore the test stand functions and meet the design and test requirements for the HL-LHC magnets, the existing horizontal test facility at Fermilab underwent a significant refurbishment of the cryogenic and mechanical components. Most of the upgrades were completed and verified during so called zero-magnet test by late 2020, and then final commissioning of the upgraded horizontal test stand was completed during the first cryo-assembly test in 2023. These tests verified the major cryo-mechanical installations, as well as the basic test stand operations, including controlled cooldown and operation at 1.9 K, magnet protection and process controls. Here, in this paper, overview of the Fermilab's horizontal test facility upgrade and commissioning of these upgrades are presented.

43 PARTICLE ACCELERATORS↗

Unraveling the Stable Cathode Electrolyte Interface in all Solid‐State Thin‐Film Battery Operating at 5 V

Abstract Spinel‐type LiNi 0.5 Mn 1.5 O 4 (LNMO) is one of the most promising 5 V‐class cathode materials for Li‐ion batteries that can achieve high energy density and low production costs. However, in liquid electrolyte cells, the high voltage causes continuous cell degradation through the oxidative decomposition of carbonate‐based liquid electrolytes. In contrast, some solid‐state electrolytes have a wide electrochemical stability range and can withstand the required oxidative potential. In this work, a thin‐film battery consisting of an LNMO cathode with a solid lithium phosphorus oxynitride (LiPON) electrolyte is tested and their interface before and after cycling is characterized. With Li metal as the anode, this system can deliver stable performance for 600 cycles with an average Coulombic efficiency >99%. Neutron depth profiling indicates a slight overlithiated layer at the interface prior to cycling, a result that is consistent with the excess charge capacity measured during the first cycle. Cryogenic electron microscopy further reveals intimate contact between LNMO and LiPON without noticeable structure and chemical composition evolution after extended cycling, demonstrating the superior stability of LiPON against a high voltage cathode. Consequently, design guidelines are proposed for interface engineering that can accelerate the commercialization of a high voltage cell with solid or liquid electrolytes.

25 ENERGY STORAGE↗

Shatter Thresholds and Fragment Size Distributions of Deuterium–Neon Mixture Cryogenic Pellets for Tokamak Thermal Mitigation

Reliable mitigation is necessary to eliminate the detrimental effects of a disruption event in large high-current tokamaks such as ITER. To avoid serious damage to plasma-facing components during the thermal quench phase of a disruption, material is injected to radiate the plasma energy over the inner surface of the machine. The most promising method of material injection is a process known as shattered pellet injection (SPI). SPI utilizes cryogenic cooling to desublimate gas into the barrel of a pipe gun to form a solid pellet. High-pressure gas or a mechanical punch is used to dislodge the pellet and accelerate it into a bent tube to intentionally fracture it. Pellets made of a mixture of deuterium and neon are likely candidates for thermal mitigation. The survivability of these pellets throughout their flight path, before striking the shatter tube, is essential for reliable SPI operation. Experiments were conducted to determine intact speed limits for various mixtures. In this paper, we outline the details of brittle fracture theory and compare a theory-based model to experimental results from various mixtures of deuterium and neon pellets.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Gain stability of Hamamatsu R5912-MOD photomultipliers at low temperature

The Photon Detection System (PDS) is a crucial component of the ICARUS detector in the Short Baseline Neutrino (SBN) Program at Fermi National Accelerator Laboratory (FNAL). It consists of 360 PhotoMultiplier Tubes (PMTs) 8” Hamamatsu R5912-MOD and, since June 2020, it has been operating at the liquid Argon cryogenic temperature. During these years, the PMTs have shown gain losses as an aging effect. Using a climatic chamber at the INFN Sezione di Catania, we confirmed a stable gain for a single PMT 8” Hamamatsu R5912-MOD when operated at room temperature, and a persistent gain loss at temperatures around -70 °C, although this temperature is rather higher than that of the liquid Argon.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

First operation of undoped CsI directly coupled with SiPMs at 77 K

Abstract The light yield of a small undoped cesium iodide (CsI) crystal directly coupled with two silicon photomultipliers (SiPMs) at about 77 Kelvin was measured to be $$43.0 \pm 1.1$$ 43.0 ± 1.1 photoelectrons (PE) per keV electron-equivalent (keV $$_\text {ee}$$ ee ) using X and $$\gamma $$ γ -ray peaks from an $$^{241}$$ 241 Am radioactive source from 18 to 60 keV. The high light yield together with some other technical advantages illustrate the great potential of this novel combination for neutrino and low-mass dark matter detection, particularly at accelerator-based neutrino sources, where random background can be highly suppressed by requiring coincident triggers between SiPMs and beam pulse timing signals. Some potential drawbacks of using cryogenic SiPMs instead of photomultiplier tubes (PMTs) were identified, such as worse energy resolution and optical cross-talks between SiPMs. Their influence to rare-event detection was discussed and possible solutions were provided.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Design and demonstration of an economical SRF structure for Continuous Wave (CW), high-energy, Megawatt-class beams

Due to its very high RF-to-beam efficiency, superconducting radiofrequency (SRF) cavities have become the technology of choice for the construction of large linear accelerators (linacs) for basic science applications (examples, ESS and PIP-II). The technology is also attractive for high volume industrial applications such as electron irradiation processing of wastewater and flue gas. However, SRF’s current reliance on liquid helium for cryogenic cooling introduces infrastructural and safety challenges for use in industrial settings. Cryocooler conduction-cooling is a recently developed novel technique for operating SRF cavities without requiring liquid helium. This project aims for technical design and economic assessment of a medium energy, high average power e-beam linac based on the conduction-cooled SRF technique for high volume irradiation treatment of wastewater. The goals of this project are (1) to design a medium energy (10 MeV), high average power (1 MW) electron beam accelerator around the cryocooler conduction-cooled SRF cavity technology, (2) demonstrate the required accelerating voltage on a prototype cavity, and (3) build a cost-model to evaluate capital and operating expense of the accelerator.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Gain Stability of Hamamatsu R5912-MOD Photo-Multipliers at Low Temperature

The Photon Detection System is a crucial component of the ICARUS detector in the Short Baseline Neutrino (SBN) Program at Fermi National Accelerator Laboratory (FNAL). It consists of 360 Photo Multiplier Tubes (PMTs) 8” Hamamatsu R5912-MOD and, since June 2020, it has been operated at the liquid Argon cryogenic temperature. During these years, the PMTs have shown gain losses as an aging effect. Using a climatic chamber at the INFN Sezione di Catania, we confirmed a stable gain for a single PMT 8” Hamamatsu 5912-MOD when operated at room temperature, and a persistent gain loss at temperatures around -70°C, although far from the liquid Argon one. No gain recovery was obtained bringing the PMT back to room temperature. We suspect that dynode deterioration due to temperature gradient plays a significant role in this phenomenon. During our test, the PMT was illuminated by a 520 nm laser source and operated in current mode. The laser beam was split into two optical fibers, the first one transmitting light through Neutral Density filters and then diffusing it over the surface of the PMT photocathode. The other optical fiber was used for an independent reference measurement of the injected light via a bolometric photodetector. In this presentation, the main technical characteristics of the measurement system are shown together with preliminary results which need further investigation to elucidate the underlying mechanisms driving the gain loss and to propose new mitigation strategies.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Nb 3 Sn Superconducting Cavities by Bronze Routes for Accelerator Stewardship

This project explored the challenges of making Nb 3 Sn superconducting radio-frequency (SRF) cavities by bronze routes. The SRF research community has prioritized Nb 3 Sn for many reasons, including the possibility to operate linacs for stewardship applications in continuous-wave mode with compact cryogenic systems. Existing Nb 3 Sn approaches use a cavity body made of niobium and apply tin to the polished cavity interior, a starting point that contains the main costs of present niobium cavity technology. Further complexity is then added because a high vacuum and temperature >1100 °C must be used to prevent formation of undesirable Nb-Sn phases, de-gas interstitial contaminants, and maintain the high purity of the Nb body. The project sought a more cost-effective solution for the same performance opportunities by exploiting the Cu-Sn-Nb diffusion reactions used to make Nb 3 Sn superconducting wires for magnets, which can be carried out at ~700 °C and are compatible with much cheaper copper cavity bodies. The project also sought understanding of the materials science and factors that affect superconducting properties. The project has impacted SRF cavity technology by demonstrating feasibility of alternative routes that enable compact, high-power electron accelerators for energy, security, environment, medical, and commercial applications.

43 PARTICLE ACCELERATORS↗

Recent progress in shattered pellet injection technology in support of the ITER disruption mitigation system*

Shattered pellet injection (SPI) has been selected as the baseline technology for the disruption mitigation (DM) system for ITER. Typical SPI utilizes cryogenic cooling to desublimate low pressure (<100 mbar) gases onto a cold zone within a pipe gun barrel, forming a cylindrical pellet. Pellets are dislodged from the barrel and accelerated using either a gas driven mechanical punch or high-pressure light-gas delivered by a fast-opening valve. SPI technology developed at Oak Ridge National Laboratory is currently deployed and operational on DIII-D, JET, and KSTAR. These SPI systems are used in experiments for physics scaling to ITER thermal mitigation and runaway electron dissipation/avoidance. The pellet sizes used for these machines are in the range of 4 to 12.5 mm in diameter with length to diameter ratios (L/D) of ~1.5. The current plan for ITER SPI is to utilize pellets that are 28.5 mm in diameter with an L/D of ~2. Furthermore, the large pellet sizes, high steady-state magnetic fields, and limitations of operating in a radiation environment render much of the current technology unusable. In addition to technology improvements, a deeper understanding of pellet material properties, formation, and release is being developed for implementation in future SPI designs, specifically ITER.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Design of Stand-Alone Cryomodule based on Superconducting Quarter-Wave Resonator

Present superconducting accelerators require a central refrigeration system and piping to distribute liquid helium and nitrogen. Stand-alone cryocooler-based systems are of significant interest both to scientific and industrial customers, as they allow applications at facilities where no cryogenic equipment and expertise exists, where it is undesirable to develop additional cryogenic systems, or where a mobile system that can be transported between beamlines or facilities is required. The technical challenge of this approach is to minimize the heat losses to the liquid helium so that commercially available, self-contained cryocoolers are able to handle the thermal load. This paper presents an improved design for a stand-alone quarter-wave resonator (QWR) cryomodule a based on commercially available cryocoolers. This cryomodule has a particular application in the ATLAS intensity upgrade project where it will house a 72.75 MHz QWR for beam energy adjustments to experimental areas, where no helium cryogenic systems exist. The described cryomodule may also be the critical part of a turnkey system with application to material processing, semiconductor manufacturing, food irradiation and homeland security. The development of low heat loss peripheral components reduces cost and widens applicability of the system. We will discuss the cryomodule and RF coupler designs, including numerical thermal and structural analyses.

43 PARTICLE ACCELERATORS↗

Athermal phonon collection efficiency in diamond crystals for low mass dark matter detection

Here, we explored the efficacy of lab-grown diamonds as potential target materials for the direct detection of sub-GeV dark matter (DM) using metallic magnetic calorimeters (MMCs). Diamond, with its excellent phononic properties and the low atomic mass of the constituent carbon, can play a crucial role in detecting low mass dark matter particles. The relatively long electron-hole pair lifetime inside the crystal may provide discrimination power between the DM-induced nuclear recoil events and the background-induced electron recoil events. Utilizing the fast response times of the MMCs and their unique geometric versatility, we deployed a novel methodology for quantifying phonon dynamics inside diamond crystals. We demonstrated that lab-grown diamond crystals fabricated via the chemical vapor deposition (CVD) technique can satisfy the stringent quality requirements for sub-GeV dark matter searches. The high-quality polycrystalline CVD diamond showed a superior athermal phonon collection efficiency compared to that of the reference sapphire crystal, and achieved energy resolution 62.7 eV at the 8.05 keV copper fluorescence line. With this energy resolution, we explored the low-energy range below 100 eV and confirmed the existence of so-called low-energy excess (LEE) reported by multiple cryogenic experiments.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Fermilab’s horizontal test stand upgrade overview and commissioning

Cryo-assemblies with the low-beta Nb3Sn quadrupoles for the High Luminosity LHC (HL-LHC) upgrade will be tested at Fermilab’s magnet test facility. Total of 10 cryo-assemblies will be delivered to CERN within the US HL-LHC Accelerator Upgrade Project (AUP). The horizontal test stand at Fermilab already has been used for testing the existing LHC inner-triplet quadrupoles, but the stand and corresponding electrical and cryogenic sub-systems were not operational more than a decade. In order to restore the test stand functions and meet the design and test requirements for the high luminosity LHC magnets, the existing horizontal test facility at Fermilab underwent a significant refurbishment of the cryogenic and mechanical components. Most of the upgrades were completed and verified during so called zero-magnet test by late 2020, and then final commissioning of the upgraded test stand was completed during the first cryo-assembly test in 2023. These tests verified all the cryo-mechanical installations, as well as the test stand operations, including controlled cooldown and operation at 1.9 K, the helium recovery capabilities, magnet protection and process controls.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Numerical Analysis of High-Order Modes in SRF Resonators for Particle Accelerators

Over the past decades, superconducting technology has rapidly evolved towards high accelerating gradients and low surface resistance, making it possible to operate particle accelerators with high average beam currents and large duty factors. However, RF losses due to coherent excitation of the HOM become the limiting factor for these regimes. Unlike the cavity operating mode, which is tuned separately, the HOM parameters can significantly vary from one cavity to another due to finite mechanical tolerances during the manufacturing process. Thus, it is of utmost importance to know the HOM parameter spread in advance in order to predict unexpected cryogenic losses, overheating of beam line components and maintain stable beam dynamics. In this paper, we present a method for generating cavity geometry with an arbitrary spread of mechanical imperfections and numerically evaluating HOM statistics. Knowing the spread of HOM parameters, we calculated the probability of resonant HOM losses in SRF accelerating cavities used in CW beam current machines such as the PIP-II and LCLS-II linacs, as well as for the SRF crab-cavity for the ILC project. Finally, we present experimental results of HOM spectra measurements in hundreds of 1.3 GHz cavities installed in LCLS-II cryomodules. Studying the effects of HOM excitation results in specifications of the SRF cavity and cryomodule and can significantly impact the efficiency and reliability of the machine operation.

Lunin, Andrei [Fermilab] (ORCID:0000000290096792)↗

Review of the application piezoelectric actuators for SRF cavity tuners

Modern particle accelerators and high-energy physics experiments that deployed up to several hundred of accelerating superconducting RF cavities require accurate frequency control. This is achieved by using cavity tuners typically actuated with the piezoelectric ceramic actuators. Piezoelectric ceramic actuators have become "standard" components of the SRF cavity tuner and depending on the application could be operated in different environments: in air, at cryogenic temperature, in vacuum, and submerged in liquid helium. Different applications place different requirements on the piezo actuators, but the important parameters common to all applications are the lifetime and reliability of the actuators. Several programs targeting the development of reliable piezo actuators are presented in this contribution.

43 PARTICLE ACCELERATORS↗

Progress in $Nb_3Sn$ SRF Technology: Opportunities and Outlook

Nb3Sn superconducting radiofrequency (SRF) cavities can expand performance capabilities of particle accelerators for both the fundamental research and the industrial applications. The technology holds a great appeal especially to small-scale applications, where it can enable a turn-key compact cryocooler operation eliminating the need for complex sub-atmospheric liquid helium cryogenic plants. Since the research into Nb3Sn SRF coatings using vapor diffusion technique restarted in 2009 at Cornell University, there has been a growing number of SRF groups around the world developing this technology with a steady increase in cavity performance and system complexity. In this talk, after a short overview of SRF technology, I will present on some of the recent developments in Nb3Sn SRF cavities, focusing on recent efforts to complete the first-of-its-kind Nb3Sn 2-cavity CEBAF-type cryomodule, which was assembled and tested last year. The talk will conclude with a short overview on some of the ongoing projects and the future possibilities for Nb3Sn cavities in accelerator applications.

43 PARTICLE ACCELERATORS↗

Status of the PIP-II Cryoplant

The Proton Improvement Plan-II (PIP-II) is an essential upgrade to the Fermilab accelerator complex featuring a new 800-MeV Superconducting Radio-Frequency (SRF) linear accelerator (Linac). The Linac contains 23 SRF cryomodules with the SRF cavities operating at 2 K, a high temperature thermal shield at 40 K and low temperature intercepts at 4.5 K. The PIP-II cryoplant will provide the necessary cooling for the cryomodules and the cryogenic distribution system interconnecting cryoplant and cryomodules. This paper describes the evolution of the PIP-II cryoplant conceptual design and specifications, including the expected heat loads, required cooling features and the integrated design. The cryoplant capacity margin analysis and fast cool-down mode will also be discussed.

43 PARTICLE ACCELERATORS↗