Search NASA⌕ Search

SEARCH · Search NASA

Results for “demonstration and field testing”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 163 records · Page 9

Wide-field microwave magnetic field imaging with nitrogen-vacancy centers in diamond

Non-invasive imaging of microwave (MW) magnetic fields with microscale lateral resolution is pivotal for various applications, such as MW technologies and integrated circuit failure analysis. Diamond nitrogen-vacancy (NV) center magnetometry has emerged as an ideal tool, offering micrometer-scale resolution, millimeter-scale field of view, high sensitivity, and non-invasive imaging compatible with diverse samples. However, up until now, it has been predominantly used for imaging of static or low-frequency magnetic fields or, concerning MW field imaging, to directly characterize the same microwave device used to drive the NV spin transitions. In this work, we leverage an NV center ensemble in diamond for wide-field imaging of MW magnetic fields generated by a test device employing a differential measurement protocol. The microscope is equipped with a MW loop to induce Rabi oscillations between NV spin states, and the MW field from the device-under-test is measured through local deviations in the Rabi frequency. This differential protocol yields magnetic field maps of a 2.57 GHz MW field with a sensitivity of ∼9 μT Hz −1/2 for a total measurement duration of T=357 s, covering a 340 × 340 μm 2 field of view with a micrometer-scale spatial resolution and a device-under-test input power dynamic range of 30 dB. This work demonstrates a novel NV magnetometry protocol, based on differential Rabi frequency measurement, that extends NV wide-field imaging capabilities to imaging of weak MW magnetic fields that would be difficult to measure directly through standard NV Rabi magnetometry.

crystallographic defects↗

Physics-constrained machine learning for electrodynamics without gauge ambiguity based on Fourier transformed Maxwell’s equations

We utilize a Fourier transformation-based representation of Maxwell’s equations to develop physics-constrained neural networks for electrodynamics without gauge ambiguity, which we label the Fourier–Helmholtz–Maxwell neural operator method. In this approach, both of Gauss’s laws and Faraday’s law are built in as hard constraints, as well as the longitudinal component of Ampère–Maxwell in Fourier space, assuming the continuity equation. An encoder–decoder network acts as a solution operator for the transverse components of the Fourier transformed vector potential, $\hat{A}_⟂(k,t)$, whose two degrees of freedom are used to predict the electromagnetic fields. This method was tested on two electron beam simulations. Among the models investigated, it was found that a U-Net architecture exhibited the best performance as it trained quicker, was more accurate and generalized better than the other architectures examined. We demonstrate that our approach is useful for solving Maxwell’s equations for the electromagnetic fields generated by intense relativistic charged particle beams and that it generalizes well to unseen test data, while being orders of magnitude quicker than conventional simulations. We show that the model can be re-trained to make highly accurate predictions in as few as 20 epochs on a previously unseen data set.

97 MATHEMATICS AND COMPUTING↗

Low-Cost, Accessible Vaccine Cooler Options

In response to cold chain management requirements for COVID-19 vaccines, Los Alamos National Laboratory has investigated, built, and demonstrated viability for different cryogenic storage options. With ease-of-access and affordability in mind, these cooler units have been built using commercial off-the-shelf (COTS) components. The team was also able to design a testing method for evaluating the performance of the different vaccine cooler options as part of the Technology Evaluation and Demonstration program. The tested cooler units demonstrated compatibility with either dry ice or liquid nitrogen as the cryogen, along with several commercial solvents. This compatibility demonstration would potentially offer sufficient flexibility for temperature control continuity. Next steps are to investigate industry interest in supporting field testing of the cooler units.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Toward Intelligent Multimodal Holography for Real-Time Chemical Imaging of Dynamic Ion Separation

Molecular-level visualization of ion transport and separation dynamics in complex environments is crucial for advancing energy systems, water purification, and critical materials recovery. Achieving this requires imaging platforms that combine structural sensitivity, chemical specificity, and real-time operation. Digital off-axis holography (DOAH) provides high-throughput, label-free quantitative phase imaging but inherently lacks chemical selectivity. Integrating DOAH with complementary spectroscopic channels such as fluorescence or hyperspectral imaging introduces the needed molecular specificity, while also creating challenges in multimodal data fusion, synchronization, and computational throughput. Artificial intelligence offers a powerful route to address these limitations by uniting physics-based reconstruction with data-driven interpretation. In this Perspective, we outline a framework for intelligent multimodal holography and demonstrate its potential using a preliminary AI-driven test case. Raw DOAH holograms of lanthanide solutions subjected to magnetic field gradients were analyzed using multi-agent AI workflows that autonomously selected reconstruction tools, extracted NMF components, and generated scientific claims consistent with true paramagnetic and diamagnetic behavior. This demonstration shows how AI-enabled reasoning can deliver real-time chemical–structural interpretation directly from raw holograms. Together, these advances define a path toward adaptive, intelligent holography platforms capable of supporting in situ chemical separations, dynamic ion transport analysis, and next-generation interfacial science.

Ricchiuti, Giovanna↗

Enhancing the distribution grid resilience using cyber-physical oriented islanding strategy

The increasing penetration of distributed generations enables an innovative operation paradigm that allows islanded operation to enhance the resilience of the distribution grid. In this study, a cyber-physical oriented islanding strategy is proposed by coordinating centralised and distributed control to achieve seamless islanding transition and operational flexibility in emergency conditions. A cyber-physical control structure is developed to mitigate various disturbances (e.g. emergencies or fluctuations) according to different operation conditions. Specifically, the distributed fault isolation and seamless islanding transition are coordinated to mitigate the outage caused by unplanned islanding, while a secondary control is proposed to support primary control by reducing the power fluctuations during islanded operation. With a rapid response speed, the local cyber-physical devices are coordinated to accomplish islanding separation by selecting a feasible islanded area even under an unplanned islanding situation. A field test was conducted on a practical distribution network in China, and the results demonstrated the effectiveness and feasibility of the proposed islanding strategy.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Hydrogen Mitigation Process Installation at Nevada Solar One

The National Renewable Energy Laboratory (NREL) and Acciona Solar Power (ASP) have developed and are implementing a process that addresses the issue of hydrogen buildup in parabolic trough power plants. Our method selectively removes hydrogen from the expansion tanks of the power plant to control hydrogen levels in the circulating heat-transfer fluid (HTF). During previous work, we developed a sensor that measures hydrogen partial pressure in the expansion-tank headspace gas. We demonstrated that our sensor measures hydrogen levels over a wide range of partial pressure—from 1.33 mbar down to 0.003 mbar. More recently, we conceived and developed an integrated process module that performs both hydrogen sensing and separating functions. The sensor/separator measures hydrogen partial pressure in the headspace gas in the same way as our original sensor design. Additionally, the integrated module separates hydrogen from the headspace gas to reduce hydrogen to the level needed to maintain the performance of receivers in the collector field. We demonstrated the performance of a laboratory-scale version of this module. Testing showed that the module performed as expected: the accuracy of the sensing function was ±7%, and the hydrogen extraction rate for the separating mode was consistent with our modeling predictions. The primary benefit of this module is its simple design, both in terms of function and incorporation into the HTF subsystem of the power plant. Most recently, NREL and ASP planned, specified, and designed a mitigation process that is based on the integrated module. We are currently completing installation of this process at ASP's Nevada Solar One power plant in Boulder City, Nevada, USA. The mitigation process is being installed at ground level below the HTF expansion tanks, where it draws headspace gas from the tanks, removes hydrogen, and returns the treated gas back to the tanks. In this paper, we report progress on the installation and describe some of the many design details and challenges that we addressed during the past year. We will generate initial performance data from the Nevada Solar One mitigation process in early 2020.

41 EE - Solar Energy Technologies Office (EE-4S)↗

Adaptive Sampling for In Situ Cloud Probe (Final Report)

Clouds play a leading role in the Earth's global energy and solar radiation balance and hydrological cycle. Improving cloud models requires detailed information on the cloud microphysical properties, such as droplet size distribution and number density, liquid water content and cloud composition (droplets, ice particles), which can only be provided by aerial in situ measurements. However, for many atmospheric measurement instruments, the lack of flexibility in selecting the operational mode during operation can lead to uncertainties in sampling and measurement characteristics under continuously varying atmospheric conditions. This SBIR project is developing an advanced, compact optical imaging technology for in situ characterization of cloud hydrometeors. The development involves a deep modification of the existing Mesa Photonics’ Cloud Droplet Measurement System (CDMS) in order to implement real-time automatic adaptive sampling based on the acquired in situ data and environmental parameters. The new system, CDMS-2, implements two measurement modes: side-scatter imaging for smaller hydrometeors and direct bright-field-illumination imaging for larger hydrometeors in a significantly larger sample volume. The system measures the droplet size distribution (DSD) and number density with an added capability of discriminating between liquid water and ice hydrometeors (based on polarization-resolved side-scatter imaging). The instrument will implement automatic switching or alternating between the regular side-scatter imaging mode and sparse/large hydrometeor mode (based on the acquired data). Other adaptive sampling capabilities include variable sample volume and dynamic range (based on the measured DSD). The preferred deployment platforms are uncrewed aircraft systems (UAS) and tethered balloon/kite systems (TBS). The Phase I project achieved (or exceeded) the goals listed in the Work Plan. A CDMS-2 laboratory prototype implementing the polarization-resolved side-scatter imaging mode and direct bright-field-illumination imaging mode was designed and built. Additional capabilities included the variable illumination pulse energy and sample volume. The smallest detectable droplet diameter was improved to 3–4 μm (from the nominal 10 μm value specified for the original CDMS). Discrimination between water droplets and ice particles was experimentally demonstrated. The Phase I prototype was extensively tested and calibrated in the laboratory and also tested in the Pi Cloud Chamber at Michigan Technological University (MTU). The two intensive experimental campaigns at MTU provided unique opportunities of testing the CDMS-2 laboratory prototype under realistic warm and mixed-phase cloud conditions (stable for long periods of time), testing different sampling modes and intercomparing the CDMS-2 prototype to other co-located cloud characterization instruments. The Phase I project successfully demonstrated the feasibility of the proposed technology and identified the engineering challenges of designing a field deployable prototype instrument in Phase II. The Phase I study provides a solid basis for development, characterization and field-testing of the proposed advanced cloud probe with adaptive sampling in Phase II followed by commercialization of the technology in Phase III.

47 OTHER INSTRUMENTATION↗

Sensor Selection for MIMO Vibration [Slides]

Objectives: Introduce a sensor selection approach to assist test engineers with MIMO test design. Demonstrate the capability of the approach. Approach: Define a desired response from a field model. Supply the sensor selection technique to two lab models, with different boundary conditions than the “field” model. Compare the laboratory response to the field response using sensors selected from the approach.

42 ENGINEERING↗

Aerosol Envelope Sealing of Existing Residences

This report explores the best methods for aerosol envelope sealing of unoccupied, existing residences and documents typical leakage reductions. The project consisted of three distinct efforts: (1) scaled field demonstrations of the sealing process, tracking from setup to sealing and cleanup, (2) laboratory testing of new sealants that dry clear, making them more appropriate for retrofit applications, and (3) BEopt™ (Building Energy Optimization Tool) modeling of the energy implications of the measured reductions in leakage. Overall, aerosol sealing performance in existing homes was effective, with an average leakage reduction of 47% across all 34 sites. Conventional approaches typically only produce leakage reductions of 25%–30%. The aerosol sealing technology could provide a process for existing homes and multifamily units to gain the benefits of a well-sealed home at a reasonable cost with minimal disruption.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Evaluation of Zero-Net-Rate Pumping Tests

Accurately estimating the distribution of aquifer properties is key to understanding contaminant movement in the subsurface. The distribution of aquifer properties is typically addressed using slug or constant-rate well tests, and the pros and cons of these tests are well known. Slug tests are appealing because they avoid removing contaminated water, but their results are affected by well skin and the small volume of displaced water limits the volume of aquifer that can be evaluated. Constant-rate well tests have the disadvantage of requiring disposal of potentially contaminated water, but they can generate properties that are more representative than slug tests, and they can be used to estimate well efficiency and storativity, which are difficult to characterize using slug tests. Periodic pumping tests are appealing because they have many of the advantages and few of the disadvantages of slug and constant-rate well tests. Periodic pumping tests involve cycling the pumping rate with a regular period and measuring the resulting response in monitoring wells. Some of these tests involve imposing a periodic rate on a constant mean rate. However, other tests involve moving water out and back into the well at rates that are balanced so the net rate after each period is zero. Some zero-net-rate (ZNR) well tests use rates that follow a sinusoidal pattern, whereas others use a square wave pattern that switches between a constant rate of pumping and a constant rate of injection to achieve a zero-net rate. ZNR well tests appear to be a useful compromise between slug and constant rate tests, but methods for conducting and analyzing the results from these tests have received limited evaluation. Periodic pumping tests are typically evaluated through recorded pressure responses to a disturbance source. Recent work has demonstrated that the strain field in the vadose zone shows a response to disturbances in the underlying aquifer. Various instrument designs are available that can record vertical and horizontal strain to very precise resolutions (10-9 ε). Measuring the strain in the vadose zone can present lower costs than measuring pressure in a monitoring well, so using strain could improve the resolution of ZNR tests, as well as make these tests potentially cheaper. A ZNR periodic pumping system was constructed and used to perform tests in the Clemson, South Carolina area. The system was designed to pump and inject with a periodic square-wave, so pumping occurs at a constant rate for half the period and is followed by injection at the same rate for half the period resulting in no net gain or loss of water from the aquifer. The system is designed to generate flow rates from 1 to 3.5 gallons per minute (gpm) with a capacity of 875-gallon per half period. Pressure and strain monitoring points are located in the vicinity of the pumping well. A series of 10 ZNR periodic pumping tests were conducted at the field site, with periods ranging from 2 to 540 minutes. Pressure data were collected and recorded in four monitoring wells in various locations around the pumping well. In addition, vertical and horizontal strain and tilt data were recorded in various locations around the pumping well. Traditional aquifer tests, including slug tests and constant-rate pumping tests were conducted at the field site to provide a baseline of aquifer parameter estimates that are compared the results of ZNR tests. Pressure data measured at monitoring wells during ZNR tests were analyzed utilizing an analytical solution (Streltsova, 1988) that assumes a confined aquifer and estimates hydraulic diffusivity and transmissivity using the time lag and amplitude of the pressure signal. The storativity can be separated out from the hydraulic diffusivity using the transmissivity estimate. The time-lag and amplitude of the pressure signals were estimated using a Fourier transform. The time-lag of the primary period of the pressure increases as a linear function of distance from the pumping well, and it increases as the square root of the period of the ZNR test over a range of periods spanning two orders of magnitudes. The first few harmonics follow similar trends, but the higher frequency harmonics diverge from this trend. Strain and tilt data from various instruments in the vadose and saturated zones are periodic during ZNR tests. The time lags of the strain components increase roughly linearly with distance from the well. Many of the time lags of the strain data from the vadose zone are similar to the time lags observed in the pressure data from a similar distance and pumping period. Theoretical experiments were performed to understand how pressure and strain responds to ZNR periodic pumping. The time-lags of the simulated pressure responses match the field data trends. The results were used to validate the Streltsova (1988) solution for periodic pumping to estimate hydraulic diffusivity. Hydraulic diffusivity was estimated to be 1.8 x 10-2 m2s-1 < Dh < 9.0 x 10-2 m2s-1 using pressure data from all the wells during ZNR tests. Transmissivity was estimated to be 0.8 x 10-4 m2s-1 < T < 4.3 x 10-4 m2s-1. Assuming Storativity = T/Dh gives 1.1 x 10-3 < S < 19 x10-3. Transmissivity is used to estimate the hydraulic conductivity, K, by dividing by the assumed aquifer thickness. Two constant-rate pumping tests were conducted and analyzed using two conceptual models: The Hantush (1961) solution was used to analyze data assuming confined conditions and the Neuman (1974) solution was used to analyze data assuming unconfined conditions. The Hantush (1961) solution estimated transmissivity to be 1.6 x 10-4 m2s-1 < T < 1.8 x 10-4 m2s-1 when using data from all the wells. Storativity was estimated to be 4.4 x 10-3 < S < 8.2 x 10-3. Assuming Dh = T/S gives 0.22 x 10-2 m2s-1 < Dh < 3.6 x 10-2 m2s-1. The Neuman (1974) solution estimated transmissivity to be 0.80 x 10-4 m2s-1 < T < 0.84 x 10-4 m2s-1. Total storativity (S + Sy) was estimated to be 22 x 10-3 < S < 110 x 10-3. Storativity excluding the Sy term was estimated to be 2.2 x 10-3 < S < 2.5 x 10-3. Assuming Dh = T/S gives 0.073 x 10-2 m2s-1 < S < 0.36 x 10-2 m2s-1. Two slug tests were performed on the pumping well, PW-2. The Bouwer and Rice (1976) solution for slug tests was used to analyze the data. This solution works for both confined and unconfined conditions, so both conceptual models were covered through the analysis. Hydraulic conductivity was estimated to be 1.95 x 10-6 ms-1 < K < 2.49 x 10-6 ms-1. Statistical comparison show generally no significant difference in the estimates of Dh, K, or S made using ZNR and conventional pumping tests.. However, the total storage estimated by the Neuman (1974) solution for unconfined settings is larger than that estimate using the Streltsove analysis applied to the ZNR tests. This is likely because the Neuman solution considers delayed yield from storage that the water table, whereas the Streltsova (1988) solution assumes confined conditions. The analysis also indicates that there is a statistically significant difference between parameters estimated with conventional slug tests and those measured with either constant-rate pumping tests or ZNR tests. Hydraulic diffusivity is estimated from the time-lag and the distance from the well. The time-lags of the strain data from the vadose zone are similar to the lags of the pressure data from a similar distance. This indicates that hydraulic diffusivities estimated from the strain data measured in the vadose zone would be similar to the estimates from the pressure data measured in the aquifer. There appear to be sign reversals in some of the strain data that were corrected to estimate the time lag. The dissolved oxygen (CO) concentration was measured during several ZNR tests to evaluate the feasibility of using the procedure to increase contaminant degradation kinetics that are related to DO. The results indicate that DO can be increased during the cycling of ZNR tests in some cases.

Smith-Jones, Austin↗

An implementation of a high-order generalized finite difference method for solving the time-harmonic cold plasma wave equation in toroidal geometry

A high-order physics-informed meshless finite difference numerical technique is introduced for solving the time-harmonic cold plasma wave equation in toroidal geometries, presenting a novel application of the generalized finite difference (GFD) method to plasma wave simulations. The algorithm employs an irregular distribution of computational points, with local point density informed by the shortest wavelength derived from the cold plasma dispersion relation. Numerical stability and robustness are addressed using regularization techniques. The algorithm, implemented for two spatial dimensions, solves for the wave electric field and is demonstrated to achieve convergence rates of $\mathcal{O}$($\mathcal{h}$ $\mathcal{P}$ )⁠. Verification tests reproduce plane wave solutions, and example simulations of ion cyclotron resonance heating and electron cyclotron resonance heating demonstrate its capability, approaching realistic tokamak plasma scenarios. This work contributes to laying a foundation for the GFD method to be used in more sophisticated, optimized, and physically realistic full-wave simulations in time-harmonic plasma wave research.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

A Comprehensive Framework for Assessing Terrestrial Analogue Field Sites for Ocean Worlds

Field studies at terrestrial analogue sites represent an important contribution to the science of ocean worlds. The value of the science and technology investigations conducted at field analogue sites depends on the relevance of the analogue environment to the target ocean world. We accept that there are no perfect analogues for many of the unique environments represented by ocean worlds but suggest that a one‐to‐one matching of environmental characteristics and conditions is not crucial to the success or impact of the work. Instead, we must determine which processes and parameters are required to map directly to the target ocean world environment with high fidelity to address the science question. In this review paper, we discuss the outcomes of a workshop aimed at developing a new framework for evaluating the suitability of analogue field locations for ocean worlds research. Here we present a two‐step approach to (a) identify the most crucial processes and parameters associated with a given science question and (b) assess the fidelity of these processes and parameters at a proposed field site to those expected for the target ocean world. We demonstrate this approach in a test case evaluating three types of ocean world analogue environments with respect to a science question. The consensus document presented here equips veteran and new investigators with valuable tools to better assess and justify their analogue site selections.

58 GEOSCIENCES↗

pyEF: A Python Framework for QM and QM/MM Atom-Wise Electric Field Analysis

We introduce pyEF, a software package for computing molecular electric fields, electrostatic interaction energies, and electrostatic potentials from quantum mechanical (QM) atom-centered multipole expansions with atom-wise decomposable contributions. We demonstrate the computational efficiency and accuracy of this QM-derived electric field evaluation tool through several tests. To assess the influence of the underlying QM method and charge partitioning scheme on these electrostatic quantities, we analyze over 250 configurations of an acetone solute molecule in five solvents of variable polarity. We find that electric field calculations are highly sensitive to the choice of charge partitioning method. Even among real-space charge schemes, acetone Stark tuning rates differ by up to a factor of 2. Benchmarking computed solvent dipole moments against experimental bulk values, we conclude that the CM5, ADCH, and Hirshfeld-I charge schemes most reliably capture solvent electrostatics and therefore provide a more faithful foundation for computing electric fields. When constructed from these real-space charges, electric fields are nearly insensitive to basis set size and monotonically increase in magnitude with higher Fock exchange. We also demonstrate efficient convergence of QM electrostatics when more distant molecules are represented solely by MM point charges, reducing computational overhead. Leveraging these findings, we demonstrate the use of pyEF to deduce environmental effects on a transition metal complex from a Ga 4 L 6 12– nanocage and quantify the dominant role of organic linkers in orchestrating electrostatic preorganization.

electric fields↗

Development of an integrated platform for hardware-in-the-loop evaluation of microgrids prior to site commissioning

This paper presents an integrated hardware-in-the-loop (HIL) platform for testing the operation and control of a real-world microgrid system prior to site commissioning. The proposed testing approach shows the value of setting up an integrated HIL platform to test multiple hardware devices (including the system-level controller, device controllers, and field devices). A test bed developed for the Borrego Springs community microgrid is used as an example to demonstrate the feasibility of the integrated platform. Comprehensive tests are carried out using the Borrego Springs test bed to validate the platform, meet the test objectives, and gain valuable insight prior to site commissioning. The selected test scenarios, initial conditions, events, test metrics, etc., are similar to those defined in IEEE P2030.8. The test objectives are to evaluate the microgrid controller and the operation of the microgrid. The HIL platform presented in this paper shows good value for microgrid testing in terms of its flexibility and scalability for testing various microgrids; its accuracy in its representation of the field; the comprehensiveness of the testing capability; and the efficiency of testing, which can reduce risks prior to field deployment.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Improving the accuracy of discretisations of the vector transport equation on the lowest-order quadrilateral Raviart-Thomas finite elements

Within finite element models of fluids, vector-valued fields such as velocity or momentum variables are commonly discretised using the Raviart-Thomas elements. However, when using the lowest-order quadrilateral Raviart-Thomas elements, standard finite element discretisations of the vector transport equation typically have a low order of spatial accuracy. This paper describes two schemes that improve the accuracy of transporting such vector-valued fields on two-dimensional curved manifolds. The first scheme that is presented reconstructs the transported field in a higher-order function space, where the transport equation is then solved. The second scheme applies a mixed finite element formulation to the vector transport equation, simultaneously solving for the transported field and its vorticity. In this work, an approach to stabilising this mixed vector-vorticity formulation is presented that uses a Streamline Upwind Petrov-Galerkin (SUPG) method. These schemes are then demonstrated, along with their accuracy properties, through some numerical tests. Two new test cases are used to assess the transport of vector-valued fields on curved manifolds, solving the vector transport equation in isolation. The improvement of the schemes is also shown through two standard test cases for rotating shallow-water models.

97 MATHEMATICS AND COMPUTING↗

Diagnostic development for parallel wave-number measurement of lower hybrid waves in EAST

In this study, an eight-channel magnetic probe diagnostic system has been designed and installed adjacent to the 4.6 GHz lower hybrid (LH) grill antenna in the low-field side of the Experimental Advanced Superconducting Tokamak (EAST) in order to study the n ∥ evolution of LH waves in the first pass from the launcher to the core plasma. The magnetic probes are separated by 6.6 mm, which allows measurement of the dominant parallel refractive index n ∥ up to n ∥ = 5 for 4.6 GHz LH waves. The magnetic probes are designed to be sensitive to the magnetic field component perpendicular to the background magnetic field with a slit on the casing that encloses the probe. The intermediate frequency stage, which consists of two mixing stages, down-coverts the frequency of the measured wave signals at 4.6 GHz to 20 MHz. A bench test demonstrates the phase stability of the magnetic probe diagnostic system. By evaluating the phase variation of the measured signals along the background magnetic field, the dominant n ∥ of the LH wave in the scrape-off layer has been deduced during the 2019 experimental campaign. In the low density plasma, the measured dominant n ∥ of the LH waves is about 2.1, corresponding to the main peak 2.04 of the launched n ∥ spectrum. n ∥ deduced by the least-squares linear fit method remains near this value in the low density plasma with a high spatial correlation magnitude of 0.9. With an eight-channel probe system, a wave-number spectrum has also been deduced, which has a peak near to the measured dominant n ∥ .

47 OTHER INSTRUMENTATION↗

Self-healable Copolymer Composites for Extended Service H 2 Dispensing Hoses

In this project, we designed, synthesized and fabricated using X-winder technologies precommercialized novel, self-healingable commodity copolymer fiber-reinforced composites to extend the H 2 hose service life beyond the current target of 1000 fills. These studies demonstrated that these composites are able to withstand over 25,000 damage-repair cycles, which was the main objective of the proposed project, in the temperature range of -40 to +80 °C under variable pressures. When micro-cracks are formed after about 1,000 cycles/fueling per hose in the inner composite layer, these micro-cracks self-heal, thus extending the lifetime of a prototype inner layer of the hose. These composites were tested by exposure to H 2 fuel and demonstrated the ability to recover from mechanical damage. Thermomechanical testing combined with analysis of the stress and strain fields across the cross-section of the inner layer composite hoses also identified the ring-like stresses on the edge of inner layers arising from changes of the fiber winding angle directions from +45° to -45°. The developed novel concept that self-healing commodity copolymers can be used in the development of prototype composites for the extended service of H 2 dispensing hoses will have major implications for other energy-related technologies, where the extended service life in harsh environments is expected. In this project, we optimized, validated, and demonstrated novel copolymer fiber-reinforced composites for H 2 dispensing hose applications, which can be utilized in future manufacturing using commodity materials. The estimated cost of materials (exluding labor) is in the range of < $1.0/ft.

08 HYDROGEN↗

Diagnostic development for parallel wave-number measurement of lower hybrid waves in EAST

An eight-channel magnetic probe diagnostic system has been designed and installed adjacent to the 4.6 GHz lower hybrid (LH) grill antenna in the low-field side of the EAST tokamak in order to study the n|| evolution of lower hybrid waves in the first pass from the launcher to the core plasma. The magnetic probes are separated by 6.6 mm, which allows measurement of the dominant parallel refractive index n|| up to n|| =5 for 4.6GHz LH waves. The magnetic probes are designed to be sensitive to the magnetic field component perpendicular to the background magnetic field with a slit on the casing that encloses the probe. The intermediate frequency (IF) stage, which consists of two mixing stages, down-coverts the frequency of the measured wave signals at 4.6 GHz to 20 MHz. A bench test demonstrates the phase stability of the magnetic probe diagnostic system. By evaluating the phase variation of the measured signals along the background magnetic field, the dominant n|| of the LH wave in the scrape-off layer (SOL) has been deduced during the 2019 experimental campaign. In the low density plasma, the measured dominant n|| of the lower hybrid waves is about 2.1, corresponding to the main peak 2.04 of the launched n|| spectrum. The n|| deduced by the least square linear fit method remains near this value in the low density plasma with a high spatial correlation magnitude of 0.9. With an eight-channel probe system a wave-number spectrum has also been deduced, which has a peak near to the measured dominant n||.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗