Search NASA⌕ Search

SEARCH · Search NASA

Results for “diffraction grating”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 163 records · Page 9

Optical Signal Processing: Poisson Image Restoration and Shearing Interferometry

Optical signal processing can be performed in either digital or analog systems. Digital computers and coherent optical systems are discussed as they are used in optical signal processing. Topics include: image restoration; phase-object visualization; image contrast reversal; optical computation; image multiplexing; and fabrication of spatial filters. Digital optical data processing deals with restoration of images degraded by signal-dependent noise. When the input data of an image restoration system are the numbers of photoelectrons received from various areas of a photosensitive surface, the data are Poisson distributed with mean values proportional to the illuminance of the incoherently radiating object and background light. Optical signal processing using coherent optical systems is also discussed. Following a brief review of the pertinent details of Ronchi's diffraction grating interferometer, moire effect, carrier-frequency photography, and achromatic holography, two new shearing interferometers based on them are presented. Both interferometers can produce variable shear.

Hong, Yie-Ming↗

Holography utilizing surface plasmon resonances

A holographic recording medium with a substrate which has a diffraction grating composed of a number of spaced line ridges on the surface is discussed. The first layer consists of a metal with a plasma wavelength shorter than that of the selected light source. A second layer, or coating, on top of the first layer consists of a thin film of photosensitive emulsion. A diagram of the device is provided. The principles of operation are explained.

Cowan, J. J.↗

Skylab program payload integration. TO27 sample array

The objective of the TO27 sample array was to determine the change in optical properties of various transmissive windows, mirrors, and diffraction gratings caused by the deposition of contaminants found about the orbital assembly. The expected information to be obtained from the total TO27 sample array program is as follows: (1) effect of space contaminants on transmittance, reflectance, grating efficiency, and polarization; (2) variations in deposition of contaminants due to substrate, solar radiation, period of exposure, direction of exposure, and geometry effects; (3) identification of contaminants and source of evolution; (4) time of contaminant evolution and lingering time; and (5) guidelines for a model of spacecraft contamination.

Muscari, J. A.↗

Preliminary results Skylab experiment TO27 optical contamination in space

Current results from the TO27 experiment which was performed on the first two Skylab missions are presented. The purpose of the experiment was to determine the change in optical properties of various transmissive windows, mirrors, and diffraction gratings caused by the deposition of contaminants found about the orbital assembly and to measure the sky brightness background caused by solar illumination of particulate contaminants. The sample array system containing 248 optical surfaces and exposed outside the orbital workshop did not collect any significant contaminants. Only trace amounts of surface deposited contaminants have been seen, in all cases the measurement was near the limiting sensitivity of the instrument. Unfortunate performance compromises and the relative cleanliness of the assembly on the anti-solar side appeared to place the amount of available surface contaminants near the limiting sensitivity of the sample array. Mass spectroscopy on the trace contaminants show the presence of high molecular weight species, up to 773 amu. The data suggests the presence of condensed aromatics.

Muscari, J. A.↗

Holography with surface plasma waves

New technique utilizes reflection-type diffraction grating of type generally used in grating spectrometers. Grating is coated with thin layer of high-resolution recording medium, having absorption coefficient low enough to prevent incident light absorption before it is reflected by metal layer.

Cowan, J. J.↗

Wide-field schlieren system

System uses diffraction grating and wire grid to replace conventional mirror and knife edge, producing larger photographs at reduced costs for fluid flow applications.

Parthasarathy, S. P.↗

Large-Scale periodic solar velocities: An observational study

Observations of large-scale solar velocities were made using the mean field telescope and Babcock magnetograph of the Stanford Solar Observatory. Observations were made in the magnetically insensitive ion line at 5124 A, with light from the center (limb) of the disk right (left) circularly polarized, so that the magnetograph measures the difference in wavelength between center and limb. Computer calculations are made of the wavelength difference produced by global pulsations for spherical harmonics up to second order and of the signal produced by displacing the solar image relative to polarizing optics or diffraction grating.

Dittmer, P. H.↗

Optical design of a stigmatic spectroheliometer for photometric studies of dynamic phenomena at extreme-ultraviolet wavelengths

The design of a stigmatic spectroheliometer for photometric studies of dynamic phenomena in the solar atmosphere at extreme ultraviolet (EUV) wavelengths is described. The normal-incidence spectrometer requires only one reflective surface, and is equipped with a series of exit slits and associated one-dimensional detector arrays that are mounted at the secondary (vertical) foci of the concave diffraction grating. It is shown that such a spectrometer mounted at the focus of an off-axis paraboloid telescope mirror of the size employed in the EUV spectroheliometer flown on Skylab could record monochromatic images of a 2 x 2 (arcmin) sq field-of-view with a spatial resolution element of 1 x 1 (arcsec) sq in a time of 4 s, 24 s, or 4 min, depending on whether the region studied is flaring, active, or quiet. The resulting spectroheliograms would have an average photometric precision of 10% and a spectral purity of 0.1 A.

Huber, M. C. E.↗

General optics evaluation program

Computer program GENOPTICS is generalized aid for analysis and evaluation of optical systems that employ lenses, mirrors, diffraction gratings, and other geometrical optical surfaces. It can exactly trace up to 800 rays through as many as 40 surfaces. Results can be used to compute third order aberation coefficients including spheric contributions.

Howell, B. J.↗

An ultraviolet polarimeter for the Solar Maximum Mission

The Solar Maximum Mission experiment contingency will include one instrument originally designed and built for OSO-8. The engineering model of the OSO-8 High Resolution Spectrometer has been rebuilt to make it lightworthy and to encompass several new functions, including solar ultraviolet polarimetry. The rebuilt package is designated as the High Resolution Ultraviolet Spectrometer/Polarimeter. The device that enables polarimetry is a dual channel rotating waveplate system. The waveplates are magnesium fluoride and will allow measurements to be made ranging from the Lyman alpha line to near visible ultraviolet. One wavelength channel will use the polarization characteristics of the spectrometer diffraction grating as the analyzer. The second channel has a built-in four-mirror polarizer. This paper describes the polarimeter design, operation, and calibration.

Calvert, J.↗

Video techniques in comet-debris studies

The paper describes techniques for examining comets and meteors. Data was obtained on four nights around the peak of the Geminid shower, using SEC Vidicon equipment at Mount Hopkins Observatory in Arizona at a latitude of 31 deg 41.9 north, longitude 110 deg 52.7 west, and 2320 meters above sea level. The TV employed, was mated to an f/0.75 lens of 105 mm focal length, and agove the lens a transmission diffraction grating was fixed with 300 lines/mm. Attention is given to the calibration curve of the seven-pixer means and to the contour lines drawn by the Image Data Processing System (IDAPS).

Millman, P. M.↗

Design study for Thermal Infrared Multispectral Scanner (TIMS)

The feasibility of dividing the 8-12 micrometer thermal infrared wavelength region into six spectral bands by an airborne line scanner system was investigated. By combining an existing scanner design with a 6 band spectrometer, a system for the remote sensing of Earth resources was developed. The elements in the spectrometer include an off axis reflective collimator, a reflective diffraction grating, a triplet germanium imaging lens, a photoconductive mercury cadmium telluride sensor array, and the mechanical assembly to hold these parts and maintain their optical alignment across a broad temperature range. The existing scanner design was modified to accept the new spectrometer and two field filling thermal reference sources.

Stanich, C. G.↗

A 10 micron heterodyne receiver for ultra high resolution astronomical spectroscopy

An improved CO2 laser heterodyne spectrometer is examined. The present system uses reflective optics to eliminate refocusing at different wavelengths, and the local oscillator is a line-center-stabilized isotopic CO2 laser. A tunable diffraction grating makes possible easy and rapid selection of over 50 transitions per isotope of CO2. The IF (0 to 1.6 GHz) from the HgCdTe photomizer is analyzed by a 128-channel filter bank, consisting of 64 tunable 5-MHz filters and 64 fixed 25-MHz RF filters. These filters provide resolving powers of about 1,000,000 to 10,000,000 and velocity resolution of 50 to 250 m/sec; their output is synchronously detected, integrated, multiplexed and stored in a buffer memory for the desired integration period. Kitt Peak observations show the wide spectral coverage, wide mixer and electronics bandwidth, and high sensitivity of the system.

Buhl, D.↗

Airborne simultaneous spectroscopic detection of laser-induced water Raman backscatter and fluorescence from chlorophyll a and other naturally occurring pigments

The airborne laser-induced spectral emission bands obtained simultaneously from water Raman backscatter and the fluorescence of chlorophyll and other naturally occurring waterborne pigments are reported here for the first time. The importance of this type data lies not only in its single-shot multispectral character but also in the application of the Raman line for correction or calibration of the spatial variation of the laser penetration depth without the need for in situ water attenuation measurements. The entire laser-induced fluorescence and Raman scatter emissions resulting from each separate 532-nm 10-nsec laser pulse are collected and spectrally dispersed in a diffraction grating spectrometer having forty photomultiplier tube detectors. Results from field experiments conducted in the North Sea and the Chesapeake Bay/Potomac River are presented. Difficulties involving the multispectral resolution of the induced emissions are addressed, and feasible solutions are suggested together with new instrument configurations and future research directions.

Hoge, F. E.↗

Manipulation of Light with Magneto-optic Stripe Domain Films

Magnetic diffraction grating materials, being developed to provide a simple means of deflecting light in a two dimensional, solid state fashion are discussed. The most promising material, for several applications, appears to be bismuth substituted iron garnet films in epitaxial form. Calculations indicate that deflection efficiency greater than 60% is possible in the near infrared region of the spectrum. Within the field of view of the deflector, measurements predict that 105 resolvable spots can be expected. Applications include: (1) general purpose deflection of free laser light, (2) image processing of extended sources such as transparencies, (3) programmable lensing, and (4) fiber optic matrix switching.

Torok, E. J.↗

Planar Rowland spectrometer for fiber-optic wavelength demultiplexing

A planar Rowland spectrometer was fabricated and characterized as a wavelength demultiplexer for multimode fiber-optic applications. The spectrometer consisted of a planar multimode glass waveguide with two curved end faces and a cylindrical concave attached to one of the end faces. Semiconductor lasers with wavelengths between 0.825 and 0.845 micron were used for the measurements. Cross-talk isolation between two adjacent fibers with center-to-center separation of 175 microns (100 A in wavelength difference) was measured to be 18 dB. The device's performance was limited by grating diffraction efficiency, optical aberration, waveguide dispersion, and waveguide losses.

Yen, H. W.↗

The Mount Wilson magnetograph

In the summer of 1957, an instrument quite similar to the prototype solar magnetograph described by Babcock (1953) was installed at the 150-foot tower telescope at the Mount Wilson Observatory, and daily magnetograph observations of the full disk of the sun were started. During the following years, the instrument was modified and improved on several occasions. The present investigation is concerned with the present state of the magnetograph, which was largely rebuilt during 1981. Attention is given to the spectrograph entrance slit, the diffraction grating, the exit slit, the employed microprocessor, the setup procedure, the magnetic signal, the Doppler signal, and a solar magnetogram.

Howard, R.↗

A General Optical Systems Evaluation Program

General Optical Systems Evaluation Program, GENOPTICS, aids analysis and evaluation of optical systems that employ lenses, mirrors, diffraction gratings and other geometrical surfaces. GENOPTICS uses geometrical ray tracing based on Snell's law.

Wilson, M.↗