Search NASA⌕ Search

SEARCH · Search NASA

Results for “installer magnetic field”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 163 records · Page 9

Polar Hydra Data Analysis

The science activities are: 1) Hydra is still operating successfully on orbit. 2) A large amount of analysis and discovery has occurred with the Hydra ground data processing this past year. 3) Full interdetector calibration has been implemented and documented. This intercalibration was necessitated by the incorrect installation of bias resistors in the pre-acceleration stage to the electron channeltrons. This had the effect of making the counting efficiency for electrons energy dependent as well as channeltron specific. The nature of the error had no impact on the ion detection efficiency since they have a different bias arrangement. This intercalibration is so effective, that the electron and ion moment densities are routinely produced with a level of agreement better than 20%. 4) The data processing routinely removes glint in the sensors and produces public energy time spectrograms on the web overnight. 6) Routine, but more intensive computer processing codes are operational that determine for electrons and ions, the density, the flow vector, the pressure tensor and the heat flux by numerical integration. These codes use the magnetic field to sustain the quality of their output. To gain access to this high quality magnetic field within our data stream we have monitored Russell's web page for zero levels and timing files (since his data acquisition is not telemetry synchronous) and have a local reconstruction of B for our use. We have also detected a routine anomaly in the magnetometer data stream that we have documented to Chris Russell and developed an editing algorithm to intercept these "hits" and remove them from the geophysical analysis.

Scudder, J. D.↗

Dilepton Program with Time-of-Flight Detector at the STAR Experiment

Pairs of lepton and antilepton (dilepton) in a continuous mass range are one of the most experimentally challenging and golden probes of the quark-gluon plasma (QGP) produced in heavy ion collisions because they do not strongly interact with the hot and dense medium, and reflect the properties of the medium at the time the dilepton is generated. The measurements of dileptons require lepton identification with high purity and high efficiency at large detector acceptance. STAR is one of two large experiments at the relativistic heavy ion collider with a primary goal of searching for the QGP and studying its properties. The STAR experiment launched a comprehensive dielectron (e + e - ) program enabled by the time-of-flight (TOF) detector that had been fully installed in 2010. In this article, we review the decade-long R&D, the construction and performance of the STAR TOF detector, and dielectron measurements, including thermal dielectron production and dielectron production from the Breit–Wheeler process. Future perspectives are also discussed.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

NASA Tech Briefs, May 2009

Topics covered include: Valve-"Health"-Monitoring System; Microstrip Antenna for Remote Sensing of Soil Moisture and Sea Surface Salinity; Biomedical Wireless Ambulatory Crew Monitor; Wireless Avionics Packet to Support Fault Tolerance for Flight Applications; Aerobot Autonomy Architecture; Submillimeter Confocal Imaging Active Module; Traveling-Wave Maser for 32 GHz; System Synchronizes Recordings from Separated Video Cameras; Piecewise-Planar Parabolic Reflectarray Antenna; Reducing Interference in ATC Voice Communication; EOS MLS Level 1B Data Processing, Version 2.2; Auto-Generated Semantic Processing Services; Geospatial Authentication; Maneuver Automation Software; Event Driven Messaging with Role-Based Subscriptions; Estimating Relative Positions of Outer-Space Structures; Fabricating PFPE Membranes for Capillary Electrophoresis; Linear Actuator Has Long Stroke and High Resolution; Installing a Test Tap on a Metal Battery Case; Fabricating PFPE Membranes for Microfluidic Valves and Pumps; Room-Temperature-Cured Copolymers for Lithium Battery Gel Electrolytes; Catalysts for Efficient Production of Carbon Nanotubes; Amorphous Silk Fibroin Membranes for Separation of CO2; "Zero-Mass" Noninvasive Pressure Transducers; Radial-Electric-Field Piezoelectric Diaphragm Pumps; Ejector-Enhanced, Pulsed, Pressure-Gain Combustor; Suppressing Ghost Diffraction in E-Beam-Written Gratings; Target-Tracking Camera for a Metrology System; Polarimetric Imaging using Two Photoelastic Modulators; Miniature Wide-Angle Lens for Small-Pixel Electronic Camera; Modal Filters for Infrared Interferometry; Mo(3)Sb(7-x)Te(x) for Thermoelectric Power Generation; Two-Dimensional Quantum Model of a Nanotransistor; Scanning Miniature Microscopes without Lenses; Manipulating Neutral Atoms in Chip-Based Magnetic Traps; Expansion Compression Contacts for Thermoelectric Legs; Processing Electromyographic Signals to Recognize Words; Physical Principle for Generation of Randomness; DSN Beowulf Cluster-Based VLBI Correlator; Hybrid NN/SVM Computational System for Optimizing Designs; Criteria for Modeling in LES of Multicomponent Fuel Flow; Computerized Machine for Cutting Space Shuttle Thermal Tiles; Orbiting Depot and Reusable Lander for Lunar Transportation; FPGA-Based Networked Phasemeter for a Heterodyne Interferometer; Aquarius Digital Processing Unit; Three-Dimensional Optical Coherence Tomography; Benchtop Antigen Detection Technique using Nanofiltration and Fluorescent Dyes; Isolation of Precursor Cells from Waste Solid Fat Tissue; Identification of Bacteria and Determination of Biological Indicators; Further Development of Scaffolds for Regeneration of Nerves; Chemically Assisted Photocatalytic Oxidation System; Use of Atomic Oxygen for Increased Water Contact Angles of Various Polymers for Biomedical Applications; Crashworthy Seats Would Afford Superior Protection; Open-Access, Low-Magnetic-Field MRI System for Lung Research; Microfluidic Mixing Technology for a Universal Health Sensor; Microfluidic Extraction of Biomarkers using Water as Solvent; Microwell Arrays for Studying Many Individual Cells; Droplet-Based Production of Liposomes; and Identifying and Inactivating Bacterial Spores

Source record↗

Growth of Solid Solution Single Crystals

The solidification of a solid solution semiconductor, having a wide separation between liquidus and solidus has been extensively studied in ground based, high magnetic field and Spacelab experiments. Two alloys of mercury cadmium telluride have been studied; with 80.0 mole percent of HgTe and 84.8 mole percent of HgTe respectively, the remainder being cadmium telluride. Such alloys are extremely difficult to grow by directional solidification on earth due to high solutal and thermal density differences that give rise to fluid flow and consequent loss of interface shape and composition. Diffusion controlled growth is therefore impossible to achieve in conventional directional solidification. The ground based experiments consisted of growing crystals in several different configurations of heat pipe furnaces, NASA's Advanced Automated Directional Solidification Furnace (AADSF), and a similar furnace incorporated in a superconducting magnet capable of operating at up to 5T. The first microgravity experiment took place during the flight of STS-62 in March 1994, with the AADSF installed on the second United States Microgravity Payload (USMP-2). The alloy was solidified at 3/4 inch per day over a 9 day period, and for the first time a detailed evaluation was performed correlating composition variations to measured residual acceleration. The second flight experiment took place in the fourth United States Microgravity Payload Mission (USMP-4) in November 1997. Due to contamination of the furnace system, analysis shows that the conditions prevailing during the experiment were quite different from the requirements requested prior to the mission. The results indicate that the sample did accomplish the desired objectives.

Lehoczky, Sandor L.↗

Cryogenic testing of the first HL-LHC Q1/Q3 cryo-assembly at Fermilab

In early 2023, Fermilab is conducting horizontal cryogenic testing of the first Q1/Q3 cryo-assembly for the high-luminosity LHC upgrade (HL-LHC). The cryo-assembly was installed on the upgraded Fermilab horizontal test stand previously used for testing the LHC inner triplet quadrupoles. The cryogenic process requirements of this test include controlled cool-down and warm-up with a 100 K maximum temperature differential between the two ends of the cold mass, operation of a 1.3 bar, 1.9 K bath of subcooled superfluid helium during power testing and magnetic measurements, and operation at pressure up to 18 bar with full helium recovery after a quench. This paper presents the operational experience gained from this first test.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Space Flight Qualification Program for the AMS-2 Commercial Cryocoolers

The Alpha Magnetic Spectrometer-02 (AMS-02) experiment is a state-of-the-art particle physics detector containing a large superfluid helium-cooled superconducting magnet. Highly sensitive detector plates inside the magnet measure a particle's speed, momentum, charge, and path. The AMS-02 experiment will study the properties and origin of cosmic particles and nuclei including antimatter and dark matter. AMS-02 will be installed on the International Space Station on Utilization Flight-4. The experiment will be run for at least three years. To extend the life of the stored cryogen and minimize temperature gradients around the magnet, four Stirling-cycle Sunpower M87N cryocoolers will be integrated with AMS-02. The cryocooler cold tip will be connected via a flexible strap to the outer vapor cooled shield of the dewar. Initial thermal analysis shows the lifetime of the experiment is increased by a factor of 2.8 with the use of the cryocooler. The AMS-02 project selected the Sunpower M87 cryocoolers and has asked NASA Goddard to qualify the cryocoolers for space flight use. This paper describes the interfaces with the cryocoolers and presents data collected during testing of the two engineering model cryocoolers. Tests include thermal performance characterization and launch vibration testing. Magnetic field compatibility testing will be presented in a separate paper at the conference.

Shirey, K. A.↗

Local Neutral Density and Plasma Parameter Measurements in a Hollow Cathode Plume

In order to understand the cathode and keeper wear observed during the Extended Life Test (ELT) of the DS1 flight spare NSTAR thruster and provide benchmarking data for a 2D cathode/cathode-plume model, a basic understanding of the plasma and neutral gas parameters in the cathode orifice and keeper region of the cathode plume must be obtained. The JPL cathode facility is instrumented with an array of Langmuir probe diagnostics along with an optical diagnostic to measure line intensity of xenon neutrals. In order to make direct comparisons with the present model, a flat plate anode arrangement was installed for these tests. Neutral density is deduced from the scanning probe data of the plasma parameters and the measured xenon line intensity in the optical regime. The Langmuir probes are scanned both axially, out to 7.0 cm downstream of the keeper, and radially to obtain 2D profile of the plasma parameters. The optical fiber is housed in a collimating stainless steel tube, and is scanned to view across the cathode plume along cuts in front of the keeper with a resolution of 1.5 mm. The radial intensities are unfolded using the Abel inversion technique that produces radial profiles of local neutral density. In this paper, detailed measurements of the plasma parameters and the local neutral densities will be presented in the cathode/keeper plume region for a 1.5 cm diameter NEXIS cathode at 25A of discharge current at several different strengths of applied magnetic field.

Plasma density↗

First data and preliminary experimental results from a new Doppler backscattering system on the MAST-U spherical tokamak

Abstract A new Doppler backscattering (DBS) system, consisting of Q-band and V-band, has been installed and achieved its first data on the MAST-U spherical tokamak. The Q-band and V-band have separate microwave source systems, but share the same optical front-end components. The Q-band and V-band sources simultaneously generate eight (34, 36, 38, 40, 42, 44, 46 and 48 GHz) and seven (52.5, 55, 57.5, 60, 62.5, 65 and 67.5 GHz) fixed frequency probe beams, respectively. These frequencies provide a large range of radial positions from the low-field-side edge plasma to the core, and possibly to the high-field-side edge, depending on the plasma conditions. The quasi-optical system consists of a remotely-tunable polarizer, a focusing lens and a remotely-steerable mirror. By steering the mirror, the system provides remote control of the probed density fluctuation wavenumber, and allow the launch angle to match the magnetic field. The range of accessible turbulence wavenumbers (k θ ) is reasonably large with normalized wavenumberk θ ρ s ranging from <0.5 to 9. The first data acquired by this DBS system is validated by comparing with the data from the other DBS system on MAST-U (introduced in ref. [21]). An example of measuring the velocity profile spanning from the edge to the center in a high-density plasma is presented, indicating the robust capabilities of the integrated Q-band and V-band DBS systems.

Instruments & Instrumentation↗

Warm Unit Stand Assembly and Testing for Proton Improvement Plan - II

The Proton Improvement Project II (PIP II), situated at Fermilab, signifies a critical advancement in the realm of high-energy physics. PIP II, a linear accelerator renovation endeavor, aspires to double the output of the existing proton beam, reinforcing Fermilab’ s position as a vanguard in this field. The proton beam's creation involves a series of high-frequency cryomodules, necessitating environmental temperature arrays of magnets and vacuum pumps henceforth described as ‘Warm Units.’ The Warm Units include design features of : 1. insertion between the cryomodules, 2. multi-stage adjustments in six degrees of freedom to ensure precise beam alignment; 3. Natural frequency modes that avoid specified ranges. In adherence to Fermilab’ s stringent safety standards, comprehensive testing procedures are slated to validate the Warm Units' capacity to simultaneously achieve local alignment adjustments while averting low-frequency oscillation less than 15 Hertz. The testing regimen will scrutinize the Warm Units' alignment adjustment capabilities and their resilience against low-frequency oscillations, with an overarching objective of satisfying the Final Design Review criteria specific to the PIP II initiative. This project works to furnish technicians responsible for the assembly of Warm Units with a comprehensive guide for successful installation, concurrently documenting any requisite design modifications essential for achieving a real-world configuration.

43 PARTICLE ACCELERATORS↗

Dual Electron Spectrometer for Magnetospheric Multiscale Mission: Results of the Comprehensive Tests of the Engineering Test Unit

The Magnetospheric Multiscale mission (MMS) is designed to study fundamental phenomena in space plasma physics such as a magnetic reconnection. The mission consists of four spacecraft, equipped with identical scientific payloads, allowing for the first measurements of fast dynamics in the critical electron diffusion region where magnetic reconnection occurs and charged particles are demagnetized. The MMS orbit is optimized to ensure the spacecraft spend extended periods of time in locations where reconnection is known to occur: at the dayside magnetopause and in the magnetotail. In order to resolve fine structures of the three dimensional electron distributions in the diffusion region (reconnection site), the Fast Plasma Investigation's (FPI) Dual Electron Spectrometer (DES) is designed to measure three dimensional electron velocity distributions with an extremely high time resolution of 30 ms. In order to achieve this unprecedented sampling rate, four dual spectrometers, each sampling 180 x 45 degree sections of the sky, are installed on each spacecraft. We present results of the comprehensive tests performed on the DES Engineering & Test Unit (ETU). This includes main parameters of the spectrometer such as energy resolution, angular acceptance, and geometric factor along with their variations over the 16 pixels spanning the 180-degree tophat Electro Static Analyzer (ESA) field of view and over the energy of the test beam. A newly developed method for precisely defining the operational space of the instrument is presented as well. This allows optimization of the trade-off between pixel to pixel crosstalk and uniformity of the main spectrometer parameters.

Avanov, Levon A.↗

Ultra High-Temperature Magnetic Bearing System for s-CO 2 Turbines/Expanders. Phase II Final Report

The goal of this project is to design and construct of a prototype of ultra-high temperature permanent magnet (UHT–PM), which provides the force to pull the spinning shaft towards the target position in the magnetic bearing (MB) clearance circle. This project will develop a PM biased MB system, that is actively cooled to the 550°C maximum operating temperature limit of PMs. The MB test environment will include 700°C, 40krpm and 4,000 psi requirements to advance the supercritical carbon dioxide (sCO 2 ) and other types of Brayton power cycle systems. The proposed novel MBs combine PMs for supplying the bias field and electromagnets for supplying the control field, both in UHT conditions. The choice of material is the UHT Sm-Co PMs (US patent 6,451,132) due to their significantly better thermal stability. The 6-pole homopolar design permits uninterrupted force delivery via a redundant control capability (US patent 7,429,811) even if 3 poles were to fail. The Phase I efforts was to focus on development and demonstration of component technologies and detailed design of full scale components and a demonstrator test rig for use in Phase II. UHT–PMs were produced and used in the MB actuator. The operating environment of the EEC-T550 Sm-Co magnet material could be extended by implementing active cooling. Electromagnetic coils imbedded in the MB provide forces to stabilize the shaft position at the target via sensing and control stages. Shaft position sensors enable to identify the present position of the spinning shaft relative to its desired target position in the MB clearance circle (air gap). Auxiliary bearings will be installed to provide a backup support system in the event that power to the MB fails or there is a fault in a device providing current to the MB coils. For control, reliability and safety reasons the sensors and auxiliary bearings are typically located as close as possible to the MBs, which exposes them to the same environmental conditions. Development of only the actuator for the UHT environment is an inadequate approach to complete integration of the MB system in the turbine/expander. Therefore the UHT sensor and auxiliary bearing were designed and developed along with the actively cooled, UHT-PM actuator development. Although shaft position sensors are commercially available (Kaman) they may cost up to $10k per channel, and a full 5 axis magnetic suspension is best implemented with up to 20 sensors. Once successfully completed, this project will significantly extend the operating environment capability for turbomachinery applications such as nuclear power, concentrated solar thermal, fossil fuel, geothermal, and shipboard propulsion. The further advancement of UHT-PM-MB will also strengthen the US position in PM technology, which is presently heavily dominated by China. The UHT Sm-Co magnet material that will be utilized in the proposed work has been developed exclusively by the project proposer. Many actuators, motors, generators and other MB applications will greatly benefit from the proposed work.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Surface processing and discharge-conditioning of high voltage electrodes for the Ra EDM experiment

The Ra EDM experiment uses a pair of high voltage electrodes to search for the atomic electric dipole moment of 225 Ra. We use identical, plane–parallel electrodes with a primary high gradient surface of 200 mm 2 to generate reversible DC electric fields. Our statistical sensitivity is linearly proportional to the electric field strength in the electrode gap. We adapted surface decontamination and processing techniques from accelerator physics literature to chemical polish and clean a suite of newly fabricated large-grain niobium and grade-2 titanium electrodes. Three pairs of niobium electrodes and one pair of titanium electrodes were discharge-conditioned with a custom high voltage test station at electric field strengths as high as +52.5 kV/mm and –51.5 kV/mm over electrode gap sizes ranging from 0.4 mm to 2.5 mm. One pair of large-grain niobium electrodes was discharge-conditioned and validated to operate at ±20 kV/mm with steady-state leakage current ≤ 25 pA (1σ) and a polarity-averaged 98 ± 19 discharges per hour. These electrodes were installed in the Ra EDM experimental apparatus, replacing a copper electrode pair, and were revalidated to ±20 kV/mm. Here, the niobium electrodes perform at an electric field strength 3.1 times larger than the legacy copper electrodes and are ultimately limited by the maximum output of our 30 kV bipolar power supply.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Development and construction status of the Mu2e electromagnetic calorimeter mechanical structures

Abstract The Mu2e experiment at Fermilab will search for the CLFV neutrino-less coherent conversion of a muon into an electron in the field of an aluminum nucleus. The observation of this process would be the evidence of physics beyond the Standard Model. Mu2e comprises a straw-tracker, an electromagnetic calorimeter and an external veto for cosmic rays. The calorimeter provides electron identification, a fast trigger and aids track reconstruction. It is a state-of-the-art crystal calorimeter and employs 1340 pure CsI crystals readout by UV-extended SiPM and fast electronics. The design consists of two identical annular disks positioned at the relative distance of 70 cm downstream the target.The hostile Mu2e conditions (total ionizing dose of 12 krad and a neutron fluence of 5 × 10 10 n/cm 2 @ 1 MeVeq (Si)/y, 1 T magnetic field and vacuum level of 10 −4 Torr) posed tight constraints on the mechanical structures and materials choice. The support structure of the two crystal matrices employs two aluminum hollow rings and parts made of open-cell vacuum-compatible carbon fiber. SiPMs and front-end electronics for each crystal are assembled in one mechanical unit inserted in a machined copper holder. The units are supported by a plate made of vacuum-compatible material. The plate integrates the cooling system made of a network of copper lines flowing a low temperature fluid and placed in thermal contact with the copper holders. The DAQ is hosted in aluminum crates positioned on the lateral surface of the disks. The crates also integrate the DAQ electronics cooling system. We review the constraints on the calorimeter structures design, the development of all the structural components, including the simulations that have determined the materials and technological choices and the specifications of the cooling station, components production and quality assurance tests, the procedures for detector assembly, transportation and installation in the experimental area.

Instruments & Instrumentation↗

Optical design and synthetic analysis of the electron cyclotron emission imaging diagnostic of HL-2M tokamak

The electron cyclotron emission imaging (ECEI) diagnostic is a powerful tool to study the MHD and turbulent transport in magnetically confined fusion plasmas. In this work, the optical system including the local oscillator (LO) coupling and radio frequency (RF) receiving optics, has been designed and analyzed for the HL-2M ECEI diagnostic. The LO optics can illuminate the antenna array and drive the mixer diode to work efficiently, with more than 36% of the beam intensity for the channels which probe the plasma edge relative to those of channels which probe the plasma core. The RF optics aims at guiding the plasma emission signal to the antenna array. To meet different physical requirements, three types of field of view have been achieved for the plasma imaging, with zoom factors of around 1, 1.5 and 2, respectively. The focal surfaces are almost flat, with a maximum off-mapping (defined as the radial distance between the beam waists of the lower-/uppermost antennas and electron cyclotron emission layer) less than 2.5 cm, which can match the electron cyclotron emission layer quite well and suppress the image distortion in the plasma edge region. Furthermore, the impact of possible vibrations and installation error on the focal plane has been evaluated. In addition, the predefined MHD and turbulence perturbations are well reproduced by combining the optical simulation results and synthetic ECEI modeling, which further verifies the good performance of the RF optics.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Low frequency, 100–600 MHz, searches with axion cavity haloscopes

We investigate reentrant and dielectric loaded cavities for the purpose of extending the range of axion cavity haloscopes to lower masses, below the range where the Axion Dark Matter experiment (ADMX) has already searched. Reentrant and dielectric loaded cavities were simulated numerically to calculate and optimize their form factors and quality factors. A prototype reentrant cavity was built and its measured properties were compared with the simulations. We estimate the sensitivity of axion dark matter searches using reentrant and dielectric loaded cavities inserted in the existing ADMX magnet at the University of Washington and a large magnet being installed at Fermilab. Published by the American Physical Society 2024

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Thermal Hydraulic Experimental Test Article (FY2020 Status Report)

The Thermal Hydraulic Experimental Test Article (THETA) is a facility that will be used to develop sodium components and instrumentation as well as acquire experimental data for validation of reactor thermal hydraulic and safety analysis codes. The facility will simulate nominal conditions as well as protected/unprotected loss of flow accidents in a sodium-cooled fast reactor (SFR). High fidelity distributed temperature profiles of the developed flow field will be acquired with Rayleigh backscatter based optical fiber temperature sensors. The facility is being designed in partnership with systems code experts to tailor the experiment to ensure the most relevant and highest quality data for code validation. THETA is comprised of a traditional primary and secondary system. The primary system is submerged in the pool of sodium and consists of a pump, electrically heated core, intermediate heat exchanger, and connected piping and thermal barriers (redan). The secondary system, located outside of the sodium pool, consists of a pump, sodium to air heat exchanger, and connected piping and valves. Figure 1 illustrates the main components of the primary system. THETA will be installed in the Mechanisms Engineering Test Loop (METL) with the primary system in the 28 inch Test Vessel #4, Figure 2. The design work for the facility has been completed. Since the FY19 THETA status report, the THETA primary system components have been assembled and tested using de-ionized water. Some results of this testing at select Richardson and Reynolds numbers are included herein. The custom THETA sodium flowmeter (permanent magnet submersible sodium flowmeter) has been built and calibrated using sodium in an auxiliary facility against a NIST traceable vortex shedder type flowmeter. The permanent magnet flowmeter showed excellent performance, following the theoretical equation for measured voltage quite well, with an error < 3.5% at flow rates ranging from 3-24 GPM at temperatures up to 400 °C. The secondary sodium system for heat rejection from intermediate heat exchanger has been analyzed according to ASME code. All secondary side piping, fittings and a U-stamped air-to-sodium heat exchanger have been procured.

21 SPECIFIC NUCLEAR REACTORS AND ASSOCIATED PLANTS↗

Cross-field and parallel dynamics of SOL filaments in TCV

Using recently installed scrape-off layer diagnostics on the tokamak à configuration variable, we characterise the poloidal and parallel properties of turbulent filaments. We access both attached and detached divertor conditions across a wide range of core densities (f G ϵ [0.09, 0.66]) in diverted L-mode plasma configurations. With a gas puff imaging (GPI) diagnostic at the outer midplane we observed filaments with a monotonic increase in radial velocity (from 390 m s –1 to 800 m s –1 ) and cross-field radii (from 8.5 mm to 13.4 mm) with increasing core density. Interpreting the filament behaviour in the context of the two-region model, we find that they populate the ideal-interchange regime (C i ) in discharges at very low densities, and the resistive X (RX)-point regime for all other discharges. The scaling of filament velocity versus size shows good agreement with this interpretation. These results are discussed and compared with previous probe-based measurements for similar conditions, which mostly placed filaments in TCV in the resistive ballooning (RB) regime. In addition, for the first time in TCV, the parallel filament extension is studied by magnetically aligning the GPI measurements at the outboard midplane with a reciprocating probe in the divertor. In agreement with the filaments being in the ideal-interchange and the RX-point regimes, they are found to extend beyond the X-point into the outer divertor leg.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Investigating the impact of donor atoms of single-source precursors on f-element nanomaterial formation and mechanisms of initial bond cleavage

Nanotechnology is advancing exponentially, with novel discoveries and applications emerging every day across various fields, including environmental remediation, biomedicine, electronics, and textiles. Nanoparticles (NPs) are defined as particles with sizes ranging from 1 to 100 nm, and their properties are influenced by factors such as composition, phase, size, and shape. Single-source precursors (SSPs) offer a promising method for controlling the synthesis of phase-pure nanoparticles with the desired stoichiometry and have been successfully applied to prepare transition metal and lanthanide NPs. SSPs are molecular compounds that contain all the necessary components to form the final nanomaterial and decompose under mild conditions, such as heating, to create the solid-state product. The objective of this work was to garner a mechanistic understanding of cerium oxide NP formation from cerium SSPs. To achieve these goals, first, ligands with oxygen and sulfur donor atoms were synthesized; among the array of ligands synthesized, some were novel. These ligands were then chelated to cerium ions to synthesize cerium precursors. Initially, known cerium alkoxide precursors were synthesized. Subsequently, these basic cerium complexes were further manipulated through acid-base protonolysis reactions to install a diverse set of ligands. Within this body of work, 10 novel cerium precursors were successfully synthesized. The ligands and the SSPs were analyzed using nuclear magnetic resonance (NMR) and thermogravimetric analysis coupled with differential scanning calorimetry (TGA-DSC). These SSPs were then introduced to a collision-induced dissociation mass spectrometer (CID-MS), and their dissociation pathways were studied.

37 - INORGANIC, ORGANIC, PHYSICAL AND ANALYTICAL C↗