Design and Operation of a Calorimeter for Advanced Multilayer Insulation Testing

A calorimeter has been constructed to accurately measure insulation performance with a nominal 90K cold outer boundary and a 20K inner boundary. Unique features of this design include use of mechanical cryocoolers instead cryogens and measurement of the heat load with a calibrated rod to serve as a conduction path. The calorimeter is operational and has completed its first test series. The initial test series was designed to look for differences in performance between a single layer of aluminum foil and a sheet of double aluminized mylar (DAM). Although it has been speculated that the aluminum foil would perform better, since the mylar coating might not thick enough to stop the transmission of long wave length infrared radiation, our testing showed a higher heat load for the aluminum foil than the DAM. The aluminum foil showed a heat load of 132 mW at an 87 K outer temperature and 152 mW at a 107K outer temperature. Whereas the DAM showed a heat load of 66 mW at an 88 K outer temperature and 81 mW at 108 K.

Cryogenics↗

A Single-Block TRL Test Fixture for the Cryogenic Characterization of Planar Microwave Components

The High-Temperature-Superconductivity (HTS) group of the RF Technology Branch, Space Electronics Division, is actively involved in the fabrication and cryogenic characterization of planar microwave components for space applications. This process requires fast, reliable, and accurate measurement techniques not readily available. A new calibration standard/test fixture that enhances the integrity and reliability of the component characterization process has been developed. The fixture consists of 50 omega thru, reflect, delay, and device under test gold lines etched onto a 254 microns (0.010 in) thick alumina substrate. The Thru-Reflect-Line (TRL) fixture was tested at room temperature using a 30 omega, 7.62 mm (300 mil) long, gold line as a known standard. Good agreement between the experimental data and the data modelled using Sonnet's em(C) software was obtained for both the return (S(sub 11)) and insertion (S( 21)) losses. A gold two-pole bandpass filter with a 7.3 GHz center frequency was used as our Device Under Test (DUT), and the results compared with those obtained using a Short-Open-Load-Thru (SOLT) calibration technique.

Mejia, M.↗

Calibration and Data Analysis Recommendations for Three-Component Moment Balances

Fundamental characteristics of design, calibration, and application of three-component moment balances are investigated in great detail. These balances are typically used to determine loads on control surfaces, canards, or other parts that are attached to a wind tunnel model. First, three different descriptions of the load state of a moment balance are reviewed. Then, load transformations between different load formats and the combined load diagram for two of the three load components are discussed. An error analysis showed that it is critical to maximize the product of the distance between the bending moment gages and their sensitivities in order to minimize the overall error in the normal force prediction. In addition, it is important to apply a sufficient number of calibration loadings near the first bending moment gage. Then, unwanted near-linear dependencies between the two bending moment gage outputs can be avoided. The error in the bending moment prediction is also investigated that results from the elastic deformation of the metric part of the balance under load. Finally, the application of the Non-Iterative Method to three-component moment balance calibration data is described in order to obtain regression models that can be used to predict loads from measured outputs during a wind tunnel test.

Strain-Gage Balance↗

Requirements Document for a Replacement Data Acquisition System

A flight vehicle is in the developmental stages. While in development flight testing is required by both the manufacturer and customer to rate design performance. The performance of the vehicle must fulfill the agreed upon requirements. Testing of a flight vehicle during operation requires various sensors in order to record and monitor performance for evaluation. A Data Acquisition System (DAQ) is needed in order to control and capture data from various sensors placed throughout the vehicle during flight. This DAQ will receive the analog data from the suite of sensors and convert them to a digital signal that can be transmitted to a recording station where the data will later be analyzed by test experts. Some of the key features to be included in the DAQ will be a self-check operation to verify the health of all sensors including the DAQ. The DAQ will also have the capability to store sensor calibration data files loaded during assembly and transmit those files to the recording station during flight. Breakthroughs in new technologies has allowed for higher resolution recording systems and faster sampling rates. Improved sensor data using a new Data Acquisition System (DAQ) can provide important answers to questions discovered during the last few flight tests. These questions arose when the flight system expressed unexpected behaviors. Having the capability of the new DAQ in flight tests would allow for more high-fidelity data to be captured from the system during flight tests and ultimately reducing the number of required flight test. Reducing the number of flight tests also reduce developmental cost and schedule.

42 ENGINEERING↗

Detection of Micro-Leaks Through Complex Geometries Under Mechanical Load and at Cryogenic Temperature

Polymer Matrix Composite (PMC) hydrogen tanks have been proposed as an enabling technology for reducing the weight of Single-Stage-to-Orbit reusable launch vehicles where structural mass has a large impact on vehicle performance. A key development issue of these lightweight structures is the leakage of hydrogen through the composite material. The rate of hydrogen leakage can be a function of the material used, method of 6 fabrication used to manufacture the tank, mechanical load the tank must react, internal damage-state of the material, and the temperatures at which the tank must operate. A method for measuring leakage through a geometrically complex structure at cryogenic temperature and under mechanical load was developed, calibrated and used to measure hydrogen leakage through complex X-33 liquid-hydrogen tank structure sections.

Rivers, H. Kevin↗

Development of a C-ELS Specimen-Based Numerical Benchmark for Mode II Delamination and Assessment of Two VCCT-Based Propagation Strategies

A finite element (FE) benchmark example inspired by the calibrated end-loaded split (C-ELS) specimen is developed and used to assess the performance of delamination propagation capabilities based on linear elastic fracture mechanics (LEFM). The C-ELS specimen has the advantage of a longer region of stable delamination propagation compared to the existing mode II benchmark case. The new benchmark example may therefore provide a better assessment tool by enabling more stable crack growth in regions further away from the boundary conditions or load application. First, a benchmark result is created manually using two-dimensional finite element models of the C-ELS specimen with different delamination lengths. Second, the performance of the virtual crack closure technique (VCCT) delamination propagation capabilities in the Abaqus/Standard®1 FE code and the recently developed Progressive Release eXplicit-VCCT (PRX-VCCT) method are assessed by comparing the results to the benchmark case. Two examples with different starter delamination lengths are studied. A shorter starter length is chosen to create a scenario with unstable delamination propagation. A longer delamination encourages stable delamination propagation. Detailed results from three-dimensional analyses with aligned and misaligned meshes and two levels of mesh refinement are provided. In general, good agreement can be achieved between the results obtained from the quasi-static propagation analysis and the benchmark analysis. Numerical artifacts including anomalous unreleased nodes in the crack wake and zig-zag crack fronts occur for propagation analyses using Abaqus/Standard VCCT. In comparison, continuous, smooth, delamination fronts are observed for PRX-VCCT. The use of the benchmark case to assess different VCCT-based propagation strategies illustrates the value of establishing benchmark cases.

Composite Materials↗

A Phenomenological Durability Model for Environmental Barrier Coating Systems Subjected to Steam Oxidation

Environmental barrier coatings (EBC) are used to protect the silicon carbide fiber reinforced silicon carbide matrix (SiC/SiC) ceramic matrix composites (CMC) from rapid surface recession due to volatization by water vapor in a steam oxidation environment. A phenomenological modeling approach is outlined to estimate the durability of a given EBC system when exposed to steam oxidation. The report provides a step-by-step procedure to estimate the life of a given EBC system subjected to thermal loads only. Once calibrated, the methodology can predict the critical thickness of an oxide layer that will cause failure initiation/spallation as well as the remaining strength or stress that the EBC system can take for a given oxide layer thickness

Subodh K Mital↗

Iterative Strain-Gage Balance Calibration Data Analysis for Extended Independent Variable Sets

A new method was developed that makes it possible to use an extended set of independent calibration variables for an iterative analysis of wind tunnel strain gage balance calibration data. The new method permits the application of the iterative analysis method whenever the total number of balance loads and other independent calibration variables is greater than the total number of measured strain gage outputs. Iteration equations used by the iterative analysis method have the limitation that the number of independent and dependent variables must match. The new method circumvents this limitation. It simply adds a missing dependent variable to the original data set by using an additional independent variable also as an additional dependent variable. Then, the desired solution of the regression analysis problem can be obtained that fits each gage output as a function of both the original and additional independent calibration variables. The final regression coefficients can be converted to data reduction matrix coefficients because the missing dependent variables were added to the data set without changing the regression analysis result for each gage output. Therefore, the new method still supports the application of the two load iteration equation choices that the iterative method traditionally uses for the prediction of balance loads during a wind tunnel test. An example is discussed in the paper that illustrates the application of the new method to a realistic simulation of temperature dependent calibration data set of a six component balance.

Ulbrich, Norbert Manfred↗

Sensitivity analysis of the effect of wind and wake characteristics on wind turbine loads in a small wind farm

Abstract. Wind turbines are designed using a set of simulations to determine the fatigue and ultimate loads, which are typically focused solely on unwaked wind turbine operation. These structural loads can be significantly influenced by the wind inflow conditions. Turbines experience altered inflow conditions when placed in the wake of upstream turbines, which can additionally influence the fatigue and ultimate loads. It is important to understand the impact of uncertainty on the resulting loads of both unwaked and waked turbines. The goal of this work is to assess which wind-inflow-related and wake-related parameters have the greatest influence on fatigue and ultimate loads during normal operation for turbines in a three-turbine wind farm. Twenty-eight wind inflow and wake parameters are screened using an elementary effects sensitivity analysis approach to identify the parameters that lead to the largest variation in the fatigue and ultimate loads of each turbine. This study uses the National Renewable Energy Laboratory (NREL) 5 MW baseline wind turbine, simulated with OpenFAST and synthetically generated inflow based on the International Electrotechnical Commission (IEC) Kaimal turbulence spectrum with the IEC exponential coherence model using the NREL tool TurbSim. The focus is on sensitivity to individual parameters, though interactions between parameters are considered, and how sensitivity differs between waked and unwaked turbines. The results of this work show that for both waked and unwaked turbines, ambient turbulence in the primary wind direction and shear are the most sensitive parameters for turbine fatigue and ultimate loads. Secondary parameters of importance for all turbines are identified as yaw misalignment, streamwise integral length, and the exponent and streamwise components of the IEC coherence model. The tertiary parameters of importance differ between waked and unwaked turbines. Tertiary effects account for up to 9.0 % of the significant events for waked turbine ultimate loads and include veer, non-streamwise components of the IEC coherence model, Reynolds stresses, wind direction, air density, and several wake calibration parameters. For fatigue loads, tertiary effects account for up to 5.4 % of the significant events and include vertical turbulence standard deviation, lateral and vertical wind integral lengths, non-streamwise components of the IEC coherence model, Reynolds stresses, wind direction, and all wake calibration parameters. This information shows the increased importance of non-streamwise wind components and wake parameters in the fatigue and ultimate load sensitivity of downstream turbines.

17 WIND ENERGY↗

Application of Temperature Sensitivities During Iterative Strain-Gage Balance Calibration Analysis

A new method is discussed that may be used to correct wind tunnel strain-gage balance load predictions for the influence of residual temperature effects at the location of the strain-gages. The method was designed for the iterative analysis technique that is used in the aerospace testing community to predict balance loads from strain-gage outputs during a wind tunnel test. The new method implicitly applies temperature corrections to the gage outputs during the load iteration process. Therefore, it can use uncorrected gage outputs directly as input for the load calculations. The new method is applied in several steps. First, balance calibration data is analyzed in the usual manner assuming that the balance temperature was kept constant during the calibration. Then, the temperature difference relative to the calibration temperature is introduced as a new independent variable for each strain--gage output. Therefore, sensors must exist near the strain--gages so that the required temperature differences can be measured during the wind tunnel test. In addition, the format of the regression coefficient matrix needs to be extended so that it can support the new independent variables. In the next step, the extended regression coefficient matrix of the original calibration data is modified by using the manufacturer specified temperature sensitivity of each strain--gage as the regression coefficient of the corresponding temperature difference variable. Finally, the modified regression coefficient matrix is converted to a data reduction matrix that the iterative analysis technique needs for the calculation of balance loads. Original calibration data and modified check load data of NASA's MC60D balance are used to illustrate the new method.

Ulbrich, N.↗

DSN water vapor radiometer: Tropospheric range delay calibration

A discussion is presented of the Deep Space Network water vapor radiometer by means of simultaneous antenna temperature and radiosonde measurements at Edwards Air Force Base. The calibration of radiometer gain and hot load radiometric noise temperature is also described. Calibration equations are given. It is found that with a selected data set, the RMS error is less than 1 cm over a total delay range of 9 to 38 cm. Limitations on the use of the water vapor radiometer are also given.

Slobin, S. D.↗

Prediction Interval Development for Wind-Tunnel Balance Check-Loading

Results from the Facility Analysis Verification and Operational Reliability project revealed a critical gap in capability in ground-based aeronautics research applications. Without a standardized process for check-loading the wind-tunnel balance or the model system, the quality of the aerodynamic force data collected varied significantly between facilities. A prediction interval is required in order to confirm a check-loading. The prediction interval provides an expected upper and lower bound on balance load prediction at a given confidence level. A method has been developed which accounts for sources of variability due to calibration and check-load application. The prediction interval method of calculation and a case study demonstrating its use is provided. Validation of the methods is demonstrated for the case study based on the probability of capture of confirmation points.

Landman, Drew↗

Hydraulic Calibrator for Strain-Gauge Balances

Instrument for calibrating strain-gauge balances uses hydraulic actuators and load cells. Eliminates effects of nonparallelism, nonperpendicularity, and changes of cable directions upon vector sums of applied forces. Errors due to cable stretching, pulley friction, and weight inaccuracy also eliminated. New instrument rugged and transportable. Set up quickly. Developed to apply known loads to wind-tunnel models with encapsulated strain-gauge balances, also adapted for use in calibrating dynamometers, load sensors on machinery and laboratory instruments.

Skelly, Kenneth↗

Industrial PLC Network Modeling and Parameter Identification Using Sensitivity Analysis and Mean Field Variational Inference

A multiple input multiple output (MIMO) power line communication (PLC) model for industrial facilities was developed that uses the physics of a bottom-up model but can be calibrated like top-down models. The PLC model considers 4-conductor cables (three-phase conductors and a ground conductor) and has several load types, including motor loads. The model is calibrated to data using mean field variational inference with a sensitivity analysis to reduce the parameter space. The results show that the inference method can accurately identify many of the model parameters, and the model is accurate even when the network is modified.

47 OTHER INSTRUMENTATION↗

Comparison of Two Load Prediction Methods for Strain-Gage Balances

Data from a five-component semi-span balance is used to perform a systematic comparison of the load prediction accuracy of two load prediction methods. Both methods independently obtain the load prediction equations from multivariate least squares fits of balance calibration data. The first method is called the Non-Iterative Method. This approach directly uses regression models of the individual load components of a balance for the load prediction. The second method is called the Iterative Method. This alternate approach uses a load iteration equation for the load prediction that is constructed from the regression coefficients of the gage outputs of the balance. Basic characteristics of the two methods are reviewed. Afterwards, both methods are applied to calibration, check load, and wind tunnel test data of a five-component semi-span balance. Selected analysis results are compared. These comparisons confirm that the accuracy of the two methods is the same for all practical purposes.

strain-gage balance↗

Miniature Remote Deadweight Calibrator

Miniature, computer-controlled deadweight calibrator developed to calibrate remotely force transducer located in cryogenic chamber. Used with microcomputer, calibration system automatically applies deadweight loads to skin-friction balance, records and reduces data, and prints out results. Actuator controller and interlocking-weight system key elements in precise, automatic transducer calibrator. Designed for full-scale load of 1,000 mg. Concept extended to accommodate other full-scale load ranges.

Supplee, Frank H., Jr.↗

Characterizing the uncertainty in holddown post load measurements

In order to understand unexpectedly erratic load measurements in the launch-pad supports for the space shuttle, the sensitivities of the load cells in the supports were analyzed using simple probabilistic techniques. NASA engineers use the loads in the shuttle's supports to calculate critical stresses in the shuttle vehicle just before lift-off. The support loads are measured with 'load cells' which are actually structural components of the mobile launch platform which have been instrumented with strain gauges. Although these load cells adequately measure vertical loads, the horizontal load measurements have been erratic. The load measurements were simulated in this study using Monte Carlo simulation procedures. The simulation studies showed that the support loads are sensitive to small deviations in strain and calibration. In their current configuration, the load cells will not measure loads with sufficient accuracy to reliably calculate stresses in the shuttle vehicle. A simplified model of the holddown post (HDP) load measurement system was used to study the effect on load measurement accuracy for several factors, including load point deviations, gauge heights, and HDP geometry.

Richardson, J. A.↗