Search NASA⌕ Search

SEARCH · Search NASA

Results for “millimeter”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 163 records · Page 9

The Simons Observatory: science goals and forecasts for the enhanced Large Aperture Telescope

We describe updated scientific goals for the wide-field, millimeter-wave survey that will be produced by the Simons Observatory (SO). Significant upgrades to the 6-meter SO Large Aperture Telescope (LAT) are expected to be complete by 2028, and will include a doubled mapping speed with 30,000 new detectors and an automated data reduction pipeline. In addition, a new photovoltaic array will supply most of the observatory's power. The LAT survey will cover about 60% of the sky at a regular observing cadence, with five times the angular resolution and ten times the map depth of the Planck satellite. The science goals are to: (1) determine the physical conditions in the early universe and constrain the existence of new light particles; (2) measure the integrated distribution of mass, electron pressure, and electron momentum in the late-time universe, and, in combination with optical surveys, determine the neutrino mass and the effects of dark energy via tomographic measurements of the growth of structure at redshifts z ≲ 3; (3) measure the distribution of electron density and pressure around galaxy groups and clusters, and calibrate the effects of energy input from galaxy formation on the surrounding environment; (4) produce a sample of more than 30,000 galaxy clusters, and more than 100,000 extragalactic millimeter sources, including regularly sampled AGN light-curves, to study these sources and their emission physics; (5) measure the polarized emission from magnetically aligned dust grains in our Galaxy, to study the properties of dust and the role of magnetic fields in star formation; (6) constrain asteroid regoliths, search for Trans-Neptunian Objects, and either detect or eliminate large portions of the phase space in the search for Planet 9; and (7) provide a powerful new window into the transient universe on time scales of minutes to years, concurrent with observations from the Vera C. Rubin Observatory of overlapping sky.

79 ASTRONOMY AND ASTROPHYSICS↗

System-on-chip integrated circuit technology applications on the DIII-D tokamak for multi-field measurements

Several mm-wave diagnostics on the DIII-D tokamak provide multi-scale and multi-dimensional measurements of plasma profile evolution and turbulence fluctuations. Mm-wave fusion plasma diagnostics that adopt system-on-chip integrated circuit technology can provide better space utilization, flexible installation, and improved sensitivity. In order to further extend this technology for additional fusion facilities with a higher toroidal magnetic field, V-band (55–75 GHz) and F-band (90–140 GHz) chips for Microwave Imaging Reflectometer (MIR) and Electron Cyclotron Emission Imaging (ECEI) instruments are developed and tested in the Davis Millimeter Wave Research Center (DMRC). Current measurement data show that correlation between these SoC-based diagnostic instruments with other state-of-the-art diagnostics enables co-located multi-field turbulence fluctuation measurement.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Constraints on the polarization angle oscillations of the Crab Nebula with the Simons Array and its applications to the search for axionlike particles

Here, we present a search for polarization oscillation of the Crab Nebula, also known as Tau A, at millimeter wavelengths using observations with the Simons Array, the successor experiment to POLARBEAR. We follow up on previous work by POLARBEAR using 90 GHz band data of the 2023 observing season of the Simons Array to evaluate the variability of Tau A’s polarization angle. Tau A is widely used as a polarization angle calibration source in millimeter-wave astronomy, and thus it is necessary to validate the stability. Additionally, an interesting application of the time-resolved polarimetry of Tau A is to search for axionlike particles (ALPs). We do not detect a global signal across the frequencies considered in this analysis and place a median 95% upper bound of polarization oscillation amplitude A < 0.12° over oscillation frequencies from 3.39 yr -1 to 1.50 day -1 . This constrains the ALP-photon coupling at a median 95% upper bound of g aγγ < 3.84 × 10 -12 × (m a /10 -21 eV) in the mass range from 4.4 × 10 -22 to 7.2 × 10 -20 eV, assuming the ALP constitutes all of dark matter, its field is a stochastic Gaussian field, and it is the sole source of Tau A’s polarization angle oscillation. Additionally, we do not detect signal at the frequencies where 2.5σ hints were previously reported by POLARBEAR, but we do not exclude these signals at the 95% confidence level.

Adkins, Tylor [University of California, Berkeley]↗

Deep learning simulations of the microwave sky

Here we present 500 high-resolution, full-sky millimeter-wave deep learning (DL) simulations that include lensed CMB maps and correlated foreground components. We find that these MillimeterDL simulations can reproduce a wide range of non-Gaussian summary statistics matching the input training simulations, while only being optimized to match the power spectra. The procedure we develop in this work enables the capability to mass produce independent full-sky realizations from a single expensive full-sky simulation, when ordinarily the latter would not provide enough training data. We also circumvent a common limitation of high-resolution DL simulations that they be confined to small sky areas, often due to memory or GPU issues; we do this by developing a “stitching” procedure that can recover the large-scale, high-order statistics and avoid discontinuities or repeated features in the maps. In addition, since our network takes as input a full-sky lensing convergence map, it can in principle take a full-sky lensing convergence map from any large-scale structure (LSS) simulation and generate the corresponding lensed CMB and correlated foreground components at millimeter wavelengths; this is especially useful in the current era of combining results from both CMB and LSS surveys, which require a common set of simulations.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Quasiparticle Poisoning of Superconducting Qubits from Resonant Absorption of Pair-Breaking Photons

The ideal superconductor provides a pristine environment for the delicate states of a quantum computer: because there is an energy gap to excitations, there are no spurious modes with which the qubits can interact, causing irreversible decay of the quantum state. As a practical matter, however, there exists a high density of excitations out of the superconducting ground state even at ultralow temperature; these are known as quasiparticles. Observed quasiparticle densities are of order 1 μ m - 3 , tens of orders of magnitude greater than the equilibrium density expected from theory. Nonequilibrium quasiparticles extract energy from the qubit mode and can induce dephasing. Here we show that a dominant mechanism for quasiparticle poisoning is direct absorption of high-energy photons at the qubit junction. We use a Josephson junction-based photon source to controllably dose qubit circuits with millimeter-wave radiation, and we use an interferometric quantum gate sequence to reconstruct the charge parity of the qubit. We find that the structure of the qubit itself acts as a resonant antenna for millimeter-wave radiation, providing an efficient path for photons to generate quasiparticles. A deep understanding of this physics will pave the way to realization of next-generation superconducting qubits that are robust against quasiparticle poisoning.

Liu, Chuan-Hong↗

Noise Optimization for MKIDs with Different Design Geometries and Material Selections

The separation and optimization of noise components is critical to microwave-kinetic inductance detector (MKID) development. We analyze the effect of several changes to the lumped-element inductor and interdigitated capacitor geometry on the noise performance of a series of MKIDs intended for millimeter-wavelength experiments. We extract the contributions from two-level system noise in the dielectric layer, the generation-recombination noise intrinsic to the superconducting thin-film, and system white noise from each detector noise power spectrum and characterize how these noise components depend on detector geometry, material, and measurement conditions such as driving power and temperature. We observe a reduction in the amplitude of two-level system noise with both an elevated sample temperature and an increased gap between the fingers within the interdigitated capacitors for both aluminum and niobium detectors. We also verify the expected reduction of the generation-recombination noise and associated quasiparticle lifetime with reduced inductor volume. This study also iterates over different materials, including aluminum, niobium, and aluminum manganese, and compares the results with an underlying physical model.

generation-recombination noise↗

Conceptual design of the modular detector and readout system for the CMB-S4 survey experiment

We present the conceptual design of the modular detector and readout system for the Cosmic Microwave Background – Stage four (CMB-S4) ground-based survey experiment. CMB-S4 will map the cosmic microwave background (CMB) and the millimeter-wave sky to unprecedented sensitivity, using 500,000 superconducting detectors observing from Chile and Antarctica to map over 60% of the sky. The fundamental building block of the detector and readout system is a detector module package operated at 100 mK, which is connected to a readout and amplification chain that carries signals out to room temperature. It uses arrays of feedhorn-coupled orthomode transducers (OMT) that collect optical power from the sky onto dc-voltage-biased transition-edge sensor (TES) bolometers. The resulting current signal in the TESs is then amplified by a two-stage cryogenic Superconducting Quantum Interference Device (SQUID) system with a time-division multiplexer to reduce wire count, and matching room-temperature electronics to condition and transmit signals to the data acquisition system. Sensitivity and systematics requirements are being developed for the detector and readout system over wide range of observing bands (20 to 300 GHz) and optical powers to accomplish CMB-S4’s science goals. While the design incorporates the successes of previous generations of CMB instruments, CMB-S4 requires an order of magnitude more detectors than any prior experiment. This requires fabrication of complex superconducting circuits on over 10 m2 of silicon, as well as significant amounts of precision wiring, assembly and cryogenic testing

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Absence of evidence for chiral Majorana modes in quantum anomalous Hall-superconductor devices

A quantum anomalous Hall (QAH) insulator coupled to an s-wave superconductor is predicted to harbor chiral Majorana modes. A recent experiment interprets the half-quantized two-terminal conductance plateau as evidence for these modes in a millimeter-size QAH-niobium hybrid device. However, non-Majorana mechanisms can also generate similar signatures, especially in disordered samples. Here, we studied similar hybrid devices with a well-controlled and transparent interface between the superconductor and the QAH insulator. When the devices are in the QAH state with well-aligned magnetization, the two-terminal conductance is always half-quantized. Our experiment provides a comprehensive understanding of the superconducting proximity effect observed in QAH-superconductor hybrid devices and shows that the half-quantized conductance plateau is unlikely to be induced by chiral Majorana fermions in samples with a highly transparent interface.

Science & Technology - Other Topics↗

Heterogeneity in MacMullin Number of Li-Ion Battery Electrodes Studied by Means of an Aperture Probe

Heterogeneity of MacMullin number within battery electrodes is a key metric affecting cell performance. To characterize this heterogeneity, an aperture probe was developed. This probe, coupled with a newly developed transmission-line model, allows for measurements of tortuosity, represented by the MacMullin number, on millimeter length scales. Local MacMullin number values of seven electrodes were measured, and the ionic resistance profiles of these electrodes are given through contour maps of the MacMullin number. The method is validated by comparing the average MacMullin number to the value obtained through other measurement methods. The results show significant local MacMullin number variation in such electrodes on a millimeter length scale. Furthermore, this method will allow battery manufacturers and researchers to better quantify sources of heterogeneity and improve electrode quality.

25 ENERGY STORAGE↗

The Simons Observatory: HoloSim-ML: machine learning applied to the efficient analysis of radio holography measurements of complex optical systems

Near-field radio holography is a common method for measuring and aligning mirror surfaces for millimeter and sub-millimeter telescopes. In instruments with more than a single mirror, degeneracies arise in the holography measurement, requiring multiple measurements and new fitting methods. We present HoloSim-ML, a Python code for beam simulation and analysis of radio holography data from complex optical systems. This code uses machine learning to efficiently determine the position of hundreds of mirror adjusters on multiple mirrors with few micron accuracy. We apply this approach to the example of the Simons Observatory 6m telescope.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Simons Observatory: characterizing the Large Aperture Telescope Receiver with radio holography

Here, we present near-field radio holography measurements of the Simons Observatory Large Aperture Telescope Receiver optics. These measurements demonstrate that radio holography of complex millimeter-wave optical systems comprising cryogenic lenses, filters, and feed horns can provide detailed characterization of wave propagation before deployment. We used the measured amplitude and phase, at 4 K, of the receiver near-field beam pattern to predict two key performance parameters: 1) the amount of scattered light that will spill past the telescope to 300 K and 2) the beam pattern expected from the receiver when fielded on the telescope. These cryogenic measurements informed the removal of a filter, which led to improved optical efficiency and reduced sidelobes at the exit of the receiver. Holography measurements of this system suggest that the spilled power past the telescope mirrors will be less than 1%, and the main beam with its near sidelobes are consistent with the nominal telescope design. This is the first time such parameters have been confirmed in the lab prior to deployment of a new receiver. This approach is broadly applicable to millimeter and submillimeter instruments.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Laser-driven high-resolution MeV x-ray tomography

The need for high-resolution MeV x-ray tomography to observe the three-dimensional structure of dense, large-sized objects is rapidly increasing for the non-destructive evaluation of critical additively manufactured parts, national security, and other applications. We report a demonstration of high-resolution MeV computed tomography of a dense, large object with a laser-driven x-ray source. A record detector-limited MeV radiograph resolution of < 200 µm as determined with the Bennett approximation of the point spread function was achieved by irradiating millimeter-thick tungsten targets with 300 TW femtosecond laser pulses at a 0.5 Hz repetition rate. A tungsten alloy step wedge spectrometer indicates that the peak of the x-ray emission is between 1 and 2 MeV, with an endpoint energy of 19 MeV. To illustrate the radiographic imaging capability of the system, a tomographic reconstruction of a nickel superalloy turbine blade ( maximum $ρr$ = 139 g/cm 2 ) with sub-millimeter resolution was performed using 2160 individual radiographs. The small x-ray source size opens the prospect of extremely high-resolution tomographs of large, dense objects. This laser-driven approach has major advantages for non-destructive evaluation.

47 OTHER INSTRUMENTATION↗

Multiple interaction points in ghost collisions

The Ghost Collider makes use of unique “ghost” bunches, which are electrically neutral combinations of electrons and positrons within the same RF bucket, eliminates the beam-beam effects typically present at the interaction point (IP) in conventional colliders. This allows for the novel possibility of placing multiple interaction regions in series, achieving additive luminosity without introducing significant disruption. However, to get higher luminosity, the beta functions at the IP reaches millimeter scale, which in turn adds significant chromatic contribution to the collider. Correcting these chromatic effects is essential to maintain beam stability and ensure high luminosity during collider operation. By carefully adjusting the phase advance between two IRs that are placed in series, it becomes possible to cancel chromaticity globally, enabling stable collider operation while preserving high luminosity. In this paper we discuss the design of such IR/IRs to be used in a ghost collider.

Accelerator Physics↗

Ka-Band ARM Zenith Radar (KAZR) Active Remote Sensing of Clouds (ARSCL) CloudSat Calibration (KAZRARSCL-CLOUDSAT) (Value-Added Product Report)

The Ka-band ARM Zenith Radar Active Remote Sensing of CLouds CloudSat-aligned (KAZRARSCL-CLOUDSAT) Value-Added Product (VAP) applies satellite-based reflectivity calibrations to KAZRARSCL data sets. The Atmospheric Radiation Measurement (ARM) user facility has primarily used radar subsystem calibration monitoring to track cloud radar reflectivity drift over time, since reliable external calibration sources or other absolute references (such as corner reflectors) have historically been unavailable or impracticable. A study by Kollias et al. (2019) examined cloud reflectivity profiles observed with a well-characterized spaceborne downward-pointing millimeter cloud radar, operating as part of NASA’s CloudSat satellite mission (Tanelli et al. 2008). The Kollias team derived monthly statistical reflectivity offsets between CloudSat and the various generations of ARM cloud radars (millimeter wavelength cloud radar [MMCR], W-Band ARM Cloud Radar [WACR[, and Ka-band ARM Zenith Radar [KAZR]) for many, but not all, months at most fixed and mobile ARM sites over the period 2007-2017. These offsets, when available, are applied to the existing KAZRARSCL VAP products using the KAZRARSCL-CLOUDSAT VAP.

54 ENVIRONMENTAL SCIENCES↗

High-Energy Laser Direct Strike Assessment for NIF CryoXNBS Snout and Naiad SNM Container

An experimental IPT performed two NIF shots as an assessment of the effect of a direct laser beam strike impact on the NIF CryoXNBS snout and Naiad container. Four aligned NIF outer cone beams at best focus, 42 kJ total, struck a four millimeter thick stainless plate. In the first shot, the struck plate was followed by a 1.75 mm gap and a 2.0 millimeter stainless plate to create a surrogate geometry for the current CryoXNBS snout and Naiad container. There was minor plastic deformation of the rear plate rear surface with no evidence of bulk failure. The second shot tested a layered glass-filled polycarbonate and titanium shield placed in the gap. Nondestructive assay was sufficient to metrologize the beam strike area and the damage induced to the NIF target assemblies.

36 MATERIALS SCIENCE↗

Novel Concepts for High Gradient Acceleration (Final Technical Report)

We have conducted an intensive, pioneering program to demonstrate novel concepts for achieving high gradient acceleration at frequencies from the conventional microwave bands up to the millimeter wave /THz bands. High gradient accelerators hold the promise of smaller and less costly accelerators for applications ranging from the largest scale accelerators used for discovery science down to the smallest accelerators used for industrial, homeland security and medical applications. The research consisted of two major research thrusts: 1.) Structure-based wakefield accelerator (SWFA) research in collaboration with the Argonne Wakefield Accelerator research group and 2.) Millimeter Wave / THz high gradient acceleration in collaboration with SLAC. The specific goals of the research program were: Design novel metallic metamaterial structures that increase the beam-wave coupling for the accelerator mode and reduce the effect of high order modes; test novel metamaterial structures to achieve higher output power, > 1 GW at X-Band (11.7 GHz), in test at the Argonne Wakefield Accelerator (AWA); determine the experimental breakdown threshold for nanosecond-scale pulses at X-Band in testing at the AWA; test a 110 GHz accelerator structure with a field emission electron gun, built at SLAC, using pulses from a 1 MW, 110 GHz gyrotron; design, build and test a 110 GHz quasi-optical, resonant-ring pulse compressor to compress microsecond pulses from the 1 MW gyrotron into > 20 MW, 5 ns output pulses for accelerator structure testing. The proposed research program built on our successes in our research program including: Generation of 510 MW, 2.1 ns (FWHM) pulses at 11.7 GHz from a metallic metamaterial structure in test at the Argonne Wakefield Accelerator using a train of eight 65 MeV electron bunches spaced at 1.3 GHz with a total charge of 280 nC. The metamaterial structure consisted of 100 copper unit cells each consisting of a “wagon-wheel” plate and a spacer plate with a total structure length of 0.2 m. The 510 MW pulse generated an on-axis wakefield of 130 MV/m that could be used to accelerate a trailing witness bunch. Demonstration of coupling of an unprecedented rf power level of 575kW into a 110 GHz accelerator structure using a quasi-optical setup. The standing structure consisted of a central copper cavity located between two matching cavities fed by a TM01 mode. The 6 ns input pulses were sliced from 3 microsecond pulses from the gyrotron using a laser-driven silicon switch. We obtained an unprecedented high gradient up to 230MV/m corresponding to a peak surface electric field of more than 520 MV/m.

43 PARTICLE ACCELERATORS↗

Multiscale Cryo Electron Microscopy Reveals Interfacial Degradation and Stabilization in Battery Electrodes

Electrochemical interfaces are dynamic systems, evolving based on their local environment and reactant surface structures. The electrode-electrolyte interface in Li-ion batteries can be protective, limiting parasitic reactions with the electrolyte to passivate the surface [1]. Additionally, this interphase has an impact on the Li-ion transport through that layer based on its composition, bonding environment, and thickness. These parameters are challenging to collect and may vary depending on the electrode surface site investigated relative to its spatial position in a coin cell. This study will detail a multiscale cryogenic electron microscopy approach where millimeter-scale cross-sections through the coin cell batteries were made using a cryogenic stage within a fs-laser plasma focused ion beam (laser PFIB) with complementary energy dispersive X-ray spectroscopy able to detect variations in the composition at electrode interfaces [2]. Microscale cross-sectioning and lamella sample preparation of battery electrodes was conducted at the Center for Integrated Nanotechnologies using a Ga-ion focused ion beam (FIB) with air-free and cryo-transfer [3], followed by nanoscale mapping of composition and bonding within the CEI through cryo-scanning transmission electron microscopy (cryo-STEM) electron energy loss spectroscopy [4]. This multiscale approach enabled identification of millimeter-scale features of a battery stack with visualization of degradation in electrodes such as cracks in cathode particles, gas evolution, and SEI evolution; microscale interfacial characteristics, such as heterogeneity in the SEI or barrier layer and identification of electrolyte networks to the electrode surfaces; and nanoscale measurement of the CEI thickness, mapping of transition metal bonding within the cathode particles to identify loss of active materials, and identification of beneficial electrolyte additives incorporated into the CEI structure. This multiscale approach allows for a statistical understanding of the primary mechanisms and parasitic degradation pathways that impact performance by limiting the ion transport pathways within Li+ batteries.

36 MATERIALS SCIENCE↗

How Much Attenuation Extinguishes mm-Wave Vertically Pointing Radar Return Signals?

Vertically pointing radars (VPRs) operating at millimeter wavelengths measure the power return from raindrops enabling precipitation retrievals as a function of height. However, as the rain rate increases, there are combinations of rain rate and rain path length that produce sufficient attenuation to prevent the radar from detecting raindrops all the way through rain shafts. This study explores the question: Which rain rate and path length combinations completely extinguish radar return signals for VPRs operating between 3 and 200 GHz? An important step in these simulations is converting attenuated radar reflectivity factor into radar received signal-to-noise ratio (SNR) in order to determine the range where the SNR drops below the receiver detection threshold. Configuring the simulations to mimic a U.S. Department of Energy Atmospheric Radiation Mission (ARM) W-band (95 GHz) radar deployed in Brazil, the simulation results indicate that a W-band radar could observe raindrops above 3.5 km only when the rain rate was less than approximately 4 mm h -1 . The deployed W-band radar measurements confirm the simulation results with maximum observed heights ranging between 3 and 4.5 km when a surface disdrometer measured 4 mm h -1 rain rate (based on 25-to-75 percentiles from over 25,000 W-band radar profiles). In summary, this study contributes to our understanding of how rain and atmospheric gas attenuation impacts the performance of millimeter-wave VPRs and will help with the design and configuration of multi-frequency VPRs deployed in future field campaigns.

54 ENVIRONMENTAL SCIENCES↗