Search NASA⌕ Search

SEARCH · Search NASA

Results for “neutron dosimetry”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 163 records · Page 9

Measuring aerosol collection efficiency for the Bladewerx “New Speclon TM 5” and the older “Speclon TM 5” filter

Bladewerx TM LLC (Rio Rancho, NM) manufactures instrumentation, neutron shielding and activation foils for the radiation protection industry. Specializing in portable alpha/beta air monitors and sample counters, Bladewerx is the source of Speclon TM PTFE filter media that they recommend for high-resolution alpha spectroscopy. Los Alamos National Laboratory (LANL) utilizes Speclon TM filter material in CAM (Continuous Air Monitor) samplers for workplace air monitoring. The LANL Aerosol Engineering Facility received air filter material from Bladewerx, referred to as “New Speclon 5” in this document, in order to distinguish from filter material that was previously received (referred to as “Speclon 5” in this document). In this document, the aerosol collection efficiency and airflow resistance (pressure drop) were measured for the New Speclon 5 filter material.

61 RADIATION PROTECTION AND DOSIMETRY↗

Implementation of Distributed Memory Computing in MOSAIC to Enable Large 3D Simulations of Irradiated Concrete

The concrete biological shield (CBS) of light-water reactors protects workers and the surrounding environment by absorbing neutron and gamma irradiation emitted from the reactor core. The radiation dose increases with the CBS’s operational time and, in the long term, becomes significant enough to raise the question of irradiation effects on concrete—and particularly on the structural integrity of the CBS. Irradiation-induced damage has been identified as one of the main degradation mechanisms in the CBS. Neutron radiation causes the swelling of aggregate-forming minerals at different rates and amplitudes depending on the mineral’s nature. Silicate-bearing minerals such as quartz are particularly sensitive to neutron radiation and experience up to 17.8% volumetric expansion. Aggregates comprise several minerals with different orientations and are, therefore, subject to cracking as a result of mismatch strains. Additionally, the swelling of aggregates creates significant stresses in the surrounding cement paste matrix, which also results in crack formation. In parallel with the collection of characterization and irradiation test data, development of modeling and simulation tools for irradiated concrete is ongoing with the support of the US Department of Energy Office of Nuclear Energy’s Light Water Reactor Sustainability (LWRS) program. This effort resulted in the development and application of the fast-Fourier transform (FFT)–based code Microstructure-Oriented Scientific Analysis of Irradiated Concrete (MOSAIC) at Oak Ridge National Laboratory.

61 RADIATION PROTECTION AND DOSIMETRY↗

Shielding Analysis of a Preclinical Bremsstrahlung X-ray FLASH Radiotherapy System within a Clinical Radiation Therapy Vault

A preclinical radiotherapy system producing FLASH dose rates with 12 MV bremsstrahlung x rays is being developed at Stanford University and SLAC National Accelerator Laboratory. Because of the high expected workload of 6,800 Gy w –1 at the isocenter, an efficient shielding methodology is needed to protect operators and the public while the preclinical system is operated in a radiation therapy vault designed for 6 MV x rays. Here, in this study, an analysis is performed to assess the shielding of the local treatment head and radiation vault using the Monte Carlo code FLUKA and the empirical methodology given in the National Council on Radiation Protection and Measurements Report 151. Two different treatment head shielding designs were created to compare single-layer and multilayer shielding methodologies using high-Z and low-Z materials. The multilayered shielding methodology produced designs with a 17% reduction in neutron fluence leaking from the treatment head compared to the single layered design of the same size, resulting in a decreased effective dose to operators and the public. The conservative assumptions used in the empirical methods can lead to over-shielding when treatment heads use polyethylene or multilayered shielding. High-Z/Low-Z multilayered shielding optimized via Monte Carlo is shown to be effective in the case of treatment head shielding and provide more effective shielding design for external beam radiotherapy systems that use 12 MV bremsstrahlung photons. Modifications to empirical methods used in the assessment of MV radiotherapy systems may be warranted to capture the effects of polyethylene in treatment head shielding.

61 RADIATION PROTECTION AND DOSIMETRY↗

A summary of air sampler filter performance data: Bladewerx Speclon 5(TM) and Millipore FMLW047 5um

Bladewerx™ LLC (Rio Rancho, NM) manufactures instrumentation, neutron shielding and activation foils for the radiation protection industry. Specializing in portable alpha/beta air monitors and sample counters, Bladewerx is the source of Speclon 5™ PTFE filter media that they recommend for high-resolution alpha spectroscopy. Los Alamos National Laboratory (LANL) utilizes Speclon™ filter material in CAM (Continuous Air Monitor) samplers for workplace air monitoring. Millipore FMLW (5μm) filters are also used at Los Alamos, and a comparison of the two filter types has been requested. For filter face air velocities from 0.066 m/s to 1.5 m/s, the aerosol collection efficiency (for 0.3 μm particle diameters) and the filter pressure drops were measured. The FWHM (full width half maximum) of alpha spectroscopy peaks was also determined, using naturally occurring radon progeny at an alpha energy of 6 MeV.

61 RADIATION PROTECTION AND DOSIMETRY↗

MARSAME Radiological Release Report for Metal Items from TA 53, Set 18

EPC-ES has evaluated the survey results for metal items from the Los Alamos Neutron Science Center (LANSCE) and found that the metal items described in Table 1 of this report (identified by RP Tracking Numbers) meet the criteria for unrestricted release under DOE Order 458.1 Radiation Protection of the Public and the Environment and can be recycled. This conclusion is based on the known history of the metal items and on radiation survey data (see the completed RP-Form-036 LANSCE Metals Clearance Log for each item). None of the items in this report are located within radiological areas. Therefore, the items are considered unencumbered and are not subject to the moratorium suspension on metal recycling from Department of Energy facilities. Additionally, LANL has determined that there is no practical opportunity for internal DOE reuse or recycling of this metal.

54 ENVIRONMENTAL SCIENCES↗

MARSAME Radiological Release Report for Metal Items from TA 53, Set 19

EPC-ES has evaluated the survey results for metal items from the Los Alamos Neutron Science Center (LANSCE) and found that the metal items described in Table 1 of this report (identified by RP Tracking Numbers) meet the criteria for unrestricted release under DOE Order 458.1 Radiation Protection of the Public and the Environment and can be recycled. This conclusion is based on the known history of the metal items and on radiation survey data (see the completed RP-Form-036 LANSCE Metals Clearance Log for each item). None of the items in this report are located within radiological areas. Therefore, the items are considered unencumbered and are not subject to the moratorium suspension on metal recycling from Department of Energy facilities. Additionally, LANL has determined that there is no practical opportunity for internal DOE reuse or recycling of this metal.

54 ENVIRONMENTAL SCIENCES↗

Godiva IV Simulated Radiation Field Characterization and Variance Reduction

Godiva IV is a system comprised of highly enriched uranium alloyed with molybdenum in the form of fuel plate rings. The reactor, along with its predecessors, was designed with the unique ability to satisfy interests in the super-prompt-critical reactor operation space. Originally, the reactor was part of the Los Alamos Critical Experiments Facility (LACEF) at Technical Area-18 (TA-18). The radiation field around Godiva at this facility was well characterized and understood. As a fast neutron system, the neutron spectrum in and around Godiva was close to a Watt Fission spectrum. The Kiva where Godiva IV was located at LACEF was made of thin, sheet metal walls which did not contribute significantly to the neutron spectrum. Following the transition of LACEF to the National Critical Experiments and Research Center (NCERC) in Nevada, Godiva-IV was moved from TA-18 to the Device Assembly Facility (DAF) at the Nevada National Security Site (NNSS). Part of this move brought renewed interest in radiation field characterization. The new facility introduced significant changes to the environment surrounding Godiva, and preliminary foil irradiation results suggested that the room contribution to the neutron spectrum was significant. Unlike at TA-18, a large thermal neutron signature was added to the fast spectrum from Godiva due to significant room return. A primary goal due to the additional complexity that the room return adds to the Godiva IV radiation emission spectrum was the development of an efficient Monte Carlo N-Particle (MCNP) calculation capable of characterizing the neutron spectrum anywhere in the room around Godiva. A campaign of activation foil irradiations and analysis were completed to support the validation of the MCNP model. The modeling of these foils in MCNP can be easily done with a standard volumetric neutron flux tally. However, given the multitude of locations and reaction rates to be modeled, further steps must be taken to increase the efficiency of these calculations in MCNP. During this study, a benchmark model currently under development for Godiva IV was used. A qualitative assessment of the thermal neutron contributors was performed using spatial neutron distribution plots. Additional detail was added to the model based on the qualitative results showing the thermal spectrum’s large sensitivity to hydrogenous material. Neutron energy spectra was evaluated at discrete locations in the room around Godiva to quantify the relative contribution of various components. It was discovered that the concrete walls are the largest contributor to the thermal signature, with minor contributions from plastic components surrounding Godiva. Following these results, two different variance reduction techniques were implemented to improve the problem efficiency in these calculations. In the first approach, an F5 point detector tally was implemented in the standard Godiva IV criticality problem. The second approach involved a weight-window generator implementation with an F5 point detector tally in a fixed source problem. The weight window implementation reduced the runtime from 42739.55 minutes to 1803.34 minutes (computer time), compared to the F5 KCODE implementation.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Quartz Ampoule Loading, Sealing, and Inspection

This procedure applies to the loading of materials into quartz ampoules and flame sealing these ampoules. Flame sealed quartz ampoules are commonly used as a sealed containment for neutron irradiation. Due to the importance of maintaining containment for this application, this procedure involves a double encapsulation design wherein a sealed inner ampoule is sealed is in turn sealed within a larger diameter outer ampoule. General guidance for inspection of ampoules by destructive, non-destructive, qualitative (e.g., visual) and other methods are given. Materials to be placed inside the ampoules may consist of stable element materials or radioactive materials in either solid or liquid form. Liquids shall be dried prior to sealing the ampoule.

36 MATERIALS SCIENCE↗

SCALE 6.2.4 Validation: Radiation Shielding

For safe and reliable use of computer codes by the community, accuracy must be clearly evaluated. In particular, the nuclear reactor engineering and licensing field needs accurate tools for radiation shielding modeling. Monaco with Automated Variance Reduction using Importance Calculations (MAVRIC) is one such tool, with built-in variance reduction methods distributed within the SCALE code, and its validity is demonstrated in this report for the released version 6.2.4. Representative benchmarks corresponding to shielding analysis are selected for the validation study. Typical experimental results analyzed from those benchmarks include neutron fluxes, detector count rates, detector energy response functions, neutron and gamma doses, foil neutron activation rates and activities, neutron leakage fluxes, and skyshine dose rates. Thousands of points of comparison between experiment and calculation are presented in this work. Other than rare outliers typically explained by either a lack of information or large uncertainties in the experiment conditions, material, or dimensions, MAVRIC agrees well with the experiment results. MAVRIC is also compared to Monte Carlo N-Particle (MCNP) calculations when available, and both codes generally produce good agreements within estimated uncertainties. The selected benchmarks are obtained from reliable sources such as the International Criticality Safety Benchmark Evaluation Project Handbook (ICSBEP Handbook), the Shielding Integral Benchmark Archive & Database (SINBAD), and other shielding validation work found in the literature. Additional datapoints and benchmarks will be added to future versions of this report to incrementally expand the shielding validation suite incrementally.

61 RADIATION PROTECTION AND DOSIMETRY↗

Cadmium Magnesium Telluride for Next-Generation X-Ray Free Electron Laser, Synchrotron, and Many Other Applications

We developed a picosecond photodetector based on our Bridgman-grown and specially engineered cadmium magnesium telluride (Cd 1–x MgxTe) single crystal that is sensitive to both optical and X-ray pulses for coarse timing in free-electron laser applications. Cd 1–x MgxTe is a widebandgap semiconductor with potential applications, not only in optoelectronics, but also in particle physics as an intense pulse radiation detector for bremsstrahlung, X-ray/gamma-ray radiation, thermal neutrons, and medical imaging. For femtosecond optical and X-ray crosscorrelation, the material must have a very short lifetime, a condition that is opposite to that required for nuclear spectroscopy applications. At the same time, the material also needs to have a very low bulk leakage current, in the 10–90 nA range for voltages to even 1000 V. Hence, the ability to tailor or engineer the material is very crucial. Picosecond response and the crystal growth of this specially engineered Cd 1–x MgxTe material are presented. Furthermore, other characterization and transient measurements are discussed along with room-temperature semiconductor detector performance for other nuclear radiation detection applications.

36 MATERIALS SCIENCE↗

A Technical basis for in-house calibration of 252 Cf neutron source emission rates

10CFR835 stipulates that radiation protection instruments must be calibrated at least annually. Accordingly, calibration of dose rate instruments are reliant on well-known reference fields. The neutron-free-in-air facility (NFIA) located at TA36-0214 provides such a capability for neutron remmeters. One of the reference NFIA sources, 252 Cf, must be replaced every 8-10 years due to its relatively short half-life (2.645 ± 0.008 y). In the past, each newly purchased 252 Cf source has been calibrated at NIST using the Mn-bath technique prior to shipping to LANL. However, because of COVID-19 complications, the most recently acquired 252 Cf source (FTC-CF-7167) has been stored at LANL pending approval to ship to NIST for calibration. Due to the considerable expense in transporting the source to and from NIST, this TBD was written to demonstrate that new sources can be accurately calibrated via intercomparison measurements with older NIST-calibrated 252 Cf sources. It had been previously noted that such measurements yielded emission rates that agreed very well with the official rates established by NIST

252cf↗

MARSAME Radiological Release Report for Metal Items from Technical Area 53, Set 25

Environmental Protection and Compliance, Environmental Stewardship Group (EPC-ES) has evaluated the survey results for metal items from the Los Alamos Neutron Science Center (LANSCE) at Technical Area 53 (TA-53) and found that the metal items described in Table 1 of this report (identified by Radiation Protection [RP] Tracking Numbers) meet the criteria for unrestricted release under Department of Energy (DOE) Order 458.1 Chg 4, Radiation Protection of the Public and the Environment (DOE 2020) and can be recycled. This conclusion is based on the known history of the metal items and radiation survey data (see the completed RP-Form-031 LANSCE Metals Clearance Log [LANL 2021a] for each item in Attachment 1). None of the items in this report are located within radiological areas. Therefore, the items are considered unencumbered and are not subject to the moratorium suspension on metal recycling from DOE facilities. Additionally, Los Alamos National Laboratory (LANL) has determined that there is no practical opportunity for internal DOE reuse of this metal.

54 ENVIRONMENTAL SCIENCES↗

Validation of the Public Radiation Exposure Calculation for the Incident at the National Institute of Standards and Technology Center for Neutron Research on February 3, 2021

The Department of Energy/National Nuclear Security Administration Consequence Management Program was contacted by the Health Physics Chief of the National Institute of Standards and Technology Center for Neutron Research (NCNR) to review public radiation exposure calculations for an event that occurred on its Gaithersburg, Maryland, campus on February 3, 2021. Subject matter experts from the Nuclear Emergency Support Team (NEST) assets, specifically the Consequence Management Home Team (CMHT) and the National Atmospheric Release Advisory Center (NARAC), were selected to provide support. CMHT used three separate modeling codes to validate the results the scientists at NCNR calculated using the HotSpot model. The analyses were performed using NARAC’s in-house Lagrangian dispersion codes known as LODI and Aeolus, as well as the Turbo FRMAC software from Sandia National Laboratories. The team used parameters provided by the NCNR scientists regarding the site, applicable observable meteorological data, and environmental survey and sampling data to estimate public exposure. Each model estimated public dose at much less than 0.5 mrem. CMHT concurs with the NCNR public radiation exposure calculations which state that members of the public at the 400-meter boundary would have received a radiological dose of less than 0.5 mrem.

61 RADIATION PROTECTION AND DOSIMETRY↗

Comparison of Modeled to Measured Spectra using MCNP and GADRAS to Benchmark and Contrast Modeling Limitations

The desire to improve nuclear material detection through portal monitors and other low resolution detectors has led to interest in benchmarking the performance of radiation transport codes. These codes can be used to generate a variety and quantity of spectra that may be cost prohibitive to measure directly. Particular characteristics of typical detection scenarios were isolated to compare the performance of radiation transport codes to laboratory experiments. These benchmark experiments were performed to validate simulations in a number of key areas. These experiments included high areal density configurations in both one- and three-dimensional configurations. In addition, off-angle measurements were conducted to investigate the impact of detector response assumptions on complex geometries, for example where an unknown source is not physically collocated with an apparent hot spot. Furthermore, by examining both simple shielding and backscatter configurations, isolation of the scatter emanating from the object and environmental background scatter contributions to the spectra could be elucidated. A series of experiments were performed in which the order of shielding layers and the thickness were evaluated to examine the ability of the simulations to address these variables. Experiments with increasing thickness of polyethylene around a neutron source also allows for examinations of the ability of the transport simulations to properly model n,γ reactions. Finally, depleted uranium (DU) measurements have more complicated spectra than the cobalt-60 and consequently allow for investigations into the ability of transport simulations to model self-shielding. In each case, the results of the experiments were compared to MCNP simulations to judge the performance of the code, as was done previously with GADRAS 18.7.9 simulations [7]. All of the benchmark measurements were taken with a liquid nitrogen cooled 140% high purity germanium (HPGe) detector with a bismuth collimator that had the front tin filter removed. The measurement location and detector configuration were subsequently used for all experimental configurations. The remainder of this report details the experimental measurements, Section 2 and the MCNP model, Section 3. Comparisons between the experimental results and MCNP-generated spectra are performed, Section 4. Section 5 compares the results obtained with MCNP with the previously reported results obtained with GADRAS [2]. Finally, Section 6 presents the conclusions.

61 RADIATION PROTECTION AND DOSIMETRY↗

Evaluation of Oak Ridge National Laboratory Health Physics Research Reactor Operation Data for Critical Benchmark Creation [Abstract]

The Oak Ridge National Laboratory (ORNL) Health Physics Research Reactor (HPRR) was a research reactor designed and built at ORNL in 1961. The critical assembly was using a highly enriched uranium and molybdenum alloy as the fuel, and it could be operated in steady-state or burst modes. The reactor was used for about 25 years to produce a lot of publications related to dosimetry, radiobiology and radiation detectors testing before its decommissioning in 1987. In recent years, the idea of using legacy operation data from the to create a valuable critical accident alarm system shielding benchmark arose. Such a benchmark has been submitted to the International Criticality Safety Benchmark Experiment Project (ICSBEP) Technical Review Group for a potential inclusion in the 2022 version of the handbook. Another way to use the valuable data from the operation of the HPRR is to evaluate the feasibility of the creation of a subcritical or prompt supercritical benchmark for inclusion in the ICSBEP or the International Reactor Physics Experiments Evaluation Project (IRPhEP) handbooks. To initiate a burst, the HPRR had to be operated in a slightly subcritical state for a few minutes. Then, the insertion of the burst control rod would greatly increase the reactivity of the system and start the burst. No critical configuration of the HPRR critical assembly could be located. The only information available concerns stable subcritical and prompt supercritical states, found in a burst experiments’ logbook. In the recovered logbook pages, information about 8 different bursts is available. The information includes the rods positions before and during a burst, the recorded subcritical reactor period and reactivity, and the burst fission yield derived from the temperature elevation sulfur pellet irradiation analysis. By using the HPRR logbook information and the as-built drawings of the critical assembly, a highly detailed model of the HPRR was created with SCALE 6.2.4/KENO-VI. Eight KENO-VI models were created to replicate the sub-critical assembly configurations described in the eight bursts from the recovered logbook pages. KENO-VI calculates k eff and it can be linked to a reactivity value in cents by using the delayed neutron fraction B eff , also calculated by KENO-VI. KENO-VI can also be used to model the prompt super-critical configurations of the HPRR and to assess the similarity with the burst measurements by comparing the calculated k eff and the measured fission yields between each burst. Unfortunately, high uncertainty exist and the obtained discrepancies between experiments and calculation results are high, compromising the creation of a valuable critical benchmark from HPRR operation data. The reasons of the discrepancies and potential ways to solve them are explored.

21 SPECIFIC NUCLEAR REACTORS AND ASSOCIATED PLANTS↗

Uranium–Molybdenum Alloy Critical Experiments for the Design of the Health Physics Research Reactor

Clean critical experiments with a uranium-molybdenum alloy (average of 10.1616 wt. % Mo with a density of 17.08 g/cm 3 ) were performed at the Oak Ridge Critical Experiments Facility in 1961 to support the design of the Health Physics Research Reactor (HPRR). The HPRR was similar to the Godiva burst reactor at Los Alamos National Laboratory and was designed to produce 50 microseconds burst of 10 17 fission pulses of radiation for dosimetry measurements, initially in support of the determination of the doses from the nuclear detonations in Japan during World War II. These experiments reported here were used to verify the calculational methods used to design the HPRR. These delayed critical measurements were:1) a solid unreflected and unmoderated 8-in.-dimeter U-Mo cylinder, 2) an unmoderated and unreflected annulus with 8-in.-outside diameter, 2-in.-inside diameter cylinder with a central void, 3) an unmoderated and unreflected annulus with 8-in.-outside diameter, 2-in.-inside diameter cylinder with a central void filled with stainless steel, 4) Same as 3) but with 3-in-thick Plexiglas reflector on top with and without cadmium between the reflector and the U-Mo alloy assembly with steel in the center, and 5) an unmoderated and unreflected annulus which was a modification of the second but with the lower 5 inches of the central hole enlarged to 3.5 in. with various reflector conditions. The reflector conditions were: 1-in.-thick Plexiglas on all outer surfaces-void in the center; 1-in.-thick Plexiglas on all outer surfaces-Plexiglas in the center; 2-in.- thick Plexiglas on radial surface-void in the center; 6-in.-thick Plexiglas on the bottom only-Plexiglas in the center; and 6-in.-thick Plexiglas on bottom, 1-in.-thick on top and on the lower 8.25-cm.-section of the radial surface-void in the center. For some of these reflector conditions 0.025-cm.thick cadmium was located between the reflector and the U-Mo alloy. The uranium contained 93.17 wt. % 235 U. Reflection was a safety concern for this unmoderated and unreflected reactor and reduction of reflection effects was also investigated by insertion of neutron absorber around the U-Mo alloy. The stainless steel 304 contained 18% nickel and 8% chromium and the rest iron. The reflector material was a methacrylate plastic (Plexiglas) containing 5.8 x 10 22 atoms/cm 3 of hydrogen and 3.6 x 10 22 atoms/cm 3 of carbon with a density of 1.20 g/cm 3 . The purpose of this report is to document the experimental information for the measurements performed so that at a later date researchers could perform the required uncertainty and calculational analyses and documentation to use these data for an International Nuclear Criticality Safety Benchmark Program (ICSBEP) or a EURATON Nuclear Energy Agency (NEA) benchmark. The data from the experiments described should be acceptable for use as criticality safety benchmark experiments for the ICSBEP and the NEA nuclear criticality safety benchmark program, once the uncertainty analysis is completed. Based on previous ICSBEP benchmarks with this enriched uranium metal at ORCEF, the uncertainties in k eff could be as low as ±0.0002 for some configurations.

21 SPECIFIC NUCLEAR REACTORS AND ASSOCIATED PLANTS↗

Analysis of Second Target Station Target Segment Removal Dose Rates

This report documents the analysis of the dose rate fields in two configurations of the target system of the Second Target Station (STS) at the Spallation Neutron Source (SNS) at Oak Ridge National Laboratory (ORNL) in support of the remote handling target segment removal operation. The two configurations detailed in this report are both assuming 8 hours since beam was incident on the target. The first configuration assumes all shielding is in place just as it was during operation and allows for confirmation of hands-on maintenance capability of the target drive components. The second configuration assumes that a hatch in the target drive room ceiling has been opened to the high bay, the target segment removable core vessel shield block has been removed, and there is a direct line-of-sight to the target segment some 5 m below the target drive room elevation. Dose rate fields in both configurations are documented in this report along with details of the methods of computation. The dose rate fields included in this report are intended to support the engineering of remote handling special equipment and the planning of remote handing operations. The models and analysis detailed in this report are in support of the preliminary design of the STS and future analysis is needed to support the final design of the STS.

61 RADIATION PROTECTION AND DOSIMETRY↗

Monte Carlo Simulations in Support of NorthStar Irradiation Facility Commissioning Procedure

NorthStar Medical Radioisotopes LLC is constructing an irradiation facility at which electron accelerators will induce photo-transmutation (i.e., neutron knockout) of molybdenum-100 (Mo-100) to produce medically useful Mo-99. The facility will house two high-intensity electron RhodotronTM accelerators developed by IBA Industrial. The nominal power of each Rhodotron is 125kW at 40 MeV beam energy. The production target is made of metallic molybdenum enriched with Mo-100 isotope. It will be irradiated by electron beams and will itself play a role in electron conversion to intense X-rays. A full description of the NorthStar target as well as the concept of radiation shielding of the facility can be found in our previous report. The NorthStar irradiation facility is under commissioning now. The goal of the present work is to support the commissioning process by: (1) Studying residual radiation and activation to minimize personnel exposure and inform radiation waste management; (2) Using computational fluid dynamics (CFD) of the irradiated target to ensure the facility design is safe and reliable; and (3) Helping to determine radiation protection requirements during operation. Monte Carlo simulations are used for the analyses. Most of the results are presented as 3D arrays representing spatial distribution of values across simulated geometries: radiation energy depositions, ambient doses, residual isotopes accumulated, and residual doses.

07 ISOTOPE AND RADIATION SOURCES↗