Search NASA⌕ Search

SEARCH · Search NASA

Results for “nuclear explosion monitoring”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 163 records · Page 9

A digital seismogram archive of nuclear explosion signals, recorded at the Borovoye Geophysical Observatory, Kazakhstan, from 1966 to 1996

Seismologists from Kazakhstan, Russia, and the United States have rescued the Soviet-era archive of nuclear explosion seismograms recorded at Borovoye in northern Kazakhstan during the period 1966–1996. The signals had been stored on about 8000 magnetic tapes, which were held at the recording observatory. After hundreds of man-years of work, these digital waveforms together with significant metadata are now available via the project URL, namely http://www.ldeo.columbia.edu/res/pi/Monitoring/Data/ as a modern open database, of use to diverse communities. Three different sets of recording systems were operated at Borovoye, each using several different seismometers and different gain levels. For some explosions, more than twenty different channels of data are available. A first data release, in 2001, contained numerous glitches and lacked many instrument responses, but could still be used for measuring accurate arrival times and for comparison of the strengths of different types of seismic waves. The project URL also links to our second major data release, for nuclear explosions in Eurasia recorded in Borovoye, in which the data have been deglitched, all instrument responses have been included, and recording systems are described in detail. This second dataset consists of more than 3700 waveforms (digital seismograms) from almost 500 nuclear explosions in Eurasia, many of them recorded at regional distances. It is important as a training set for the development and evaluation of seismological methods of discriminating between earthquakes and underground explosions, and can be used for assessment of three-dimensional models of the Earth’s interior structure.

45 MILITARY TECHNOLOGY, WEAPONRY, AND NATIONAL DEF↗

Noble gas adsorption to tuff

For this report a method was developed to measure trace noble gas element adsorption to the surfaces of geologic materials in the presence of a background gas that could potentially compete for surface adsorption sites. Adsorption of four noble gas elements (Ne, Ar, Kr, and Xe) at a concentration of 100 ppm in helium and nitrogen were measured on a sample of crushed tuff at 0, 15, 30, and 45°C. In addition, Ne, Ar, Kr, and Xe at 250 ppm and 500 ppm in nitrogen at 15°C were measured. Noble gas adsorption was found to increase with increasing atomic mass and decreasing temperature. It was also observed that the relative increase in noble gas element adsorption with decreasing temperature tends to increase with increasing atomic mass. Noble gas adsorption from nitrogen was approximately an order of magnitude greater than for the noble gases in helium. As the noble gas concentrations in nitrogen increased, adsorption increased in a slightly non-linear fashion which could be modeled using a Freundlich isotherm. For noble gas concentrations that were ≤100 ppm Henry's Law constant were calculated.

58 GEOSCIENCES↗

Evaluation of a semiconductor-based atmospheric radioxenon detection system

A prototype radioxenon detection system for beta–gamma coincidence measurements has been designed using a PIPSBox and a pair of coplanar CdZnTe (CZT) detectors. Coincidence events are identified in real-time using a Field-Programmable Gate Array (FPGA). The measurement of 131m Xe and studies on electron backscatter and memory effect in the PIPSBox have been presented previously; this paper details the measurement of 133/133m Xe, 135 Xe, and background. Here, absolute efficiencies were determined, regions of interest were defined, and Minimum Detectable Concentrations (MDC) for all four radioxenon isotopes were calculated. When neglecting interferences between the radioxenons, the prototype system has an estimated MDC of 0.61 ± 0.15 mBq/m 3 for 133 Xe when using gas processing parameters associated with Xenon International, satisfying the CTBTO requirement for sensitivity of ≤1 mBq/m 3 for 133 Xe. Simulation suggests that by increasing number of CZT detectors used by a factor of 16, the MDCs of the system can be improved by a factor of 2-3. The design shows great promise for future improvement and expansion due to its exceptional energy resolution, high background rejection rate, room temperature operation, minimal memory effect, and simple readout electronics.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Significantly Improving Regional Seismic Amplitude Tomography at Higher Frequencies by Determining S -Wave Bandwidth

Characterizing regional seismic signals continues to be a difficult problem due to their variability. Calibration of these signals is very important to many aspects of monitoring underground nuclear explosions, including detecting seismic signals, discriminating explosions from earthquakes, and reliably estimating magnitude and yield. Amplitude tomography, which simultaneously inverts for source, propagation, and site effects, is a leading method of calibrating these signals. A major issue in amplitude tomography is the data quality of the input amplitude measurements. Pre-event and prephase signal-to-noise ratio (SNR) tests are typically used but can frequently include bad signals and exclude good signals. The deficiencies of SNR criteria, which are demonstrated here, lead to large calibration errors. To ameliorate these issues, we introduce a semi-automated approach to assess the bandwidth of a spectrum where it behaves physically. We determine the maximum frequency (denoted as F max ) where it deviates from this behavior due to inflections at which noise or spurious signals start to bias the spectra away from the expected decay. We compare two amplitude tomography runs using the SNR and new F max criteria and show significant improvements to the stability and accuracy of the tomography output for frequency bands higher than 2 Hz by using our assessments of valid S-wave bandwidth. We compare Q estimates, P/S residuals, and some detailed results to explain the improvements. Lastly, for frequency bands higher than 4 Hz, needed for effective P/S discrimination of explosions from earthquakes, the new bandwidth criteria sufficiently fix the instabilities and errors so that the residuals and calibration terms are useful for application.

58 GEOSCIENCES↗

Watchmen 3.0.0 Users Guide: Revision 6

Watchmen is a research software application developed by Pacific Northwest National Laboratory (PNNL) that incorporates the scientific and operational expertise for reviewing data from treaty monitoring radionuclide stations. The radionuclide stations are part of the International Monitoring System (IMS), a worldwide network to monitor for nuclear explosions. The data the IMS produces are critical to determine if a radionuclide release event is from a nuclear explosion. Stations deliver their measurements and system status to the International Data Centre (IDC), which forwards it via email to all subscribers. Watchmen is capable of processing data from several radioxenon station types.

97 MATHEMATICS AND COMPUTING↗

Watchmen 3.1.0 Users Guide: Revision 7

Watchmen is a research software application developed by Pacific Northwest National Laboratory (PNNL) that incorporates the scientific and operational expertise for reviewing data from treaty monitoring radionuclide stations. The radionuclide stations are part of the International Monitoring System (IMS), a worldwide network to monitor for nuclear explosions. The data the IMS produces are critical to determine if a radionuclide release event is from a nuclear explosion. Stations deliver their measurements and system status to the International Data Centre (IDC), which forwards it via email to all subscribers. Watchmen is capable of processing data from several radioxenon station types.

97 MATHEMATICS AND COMPUTING↗

Watchmen v3.2.0 User Guide: Revision 8

Watchmen is a research software application developed by Pacific Northwest National Laboratory (PNNL) that incorporates the scientific and operational expertise for reviewing data from treaty monitoring radionuclide stations. The radionuclide stations are part of the International Monitoring System (IMS), a worldwide network to monitor for nuclear explosions. The data the IMS produces are critical to determine if a radionuclide release event is from a nuclear explosion. Stations deliver their measurements and system status to the International Data Centre (IDC), which forwards it via email to all subscribers. Watchmen is capable of processing data from several radioxenon station types.

97 MATHEMATICS AND COMPUTING↗

Watchmen 3.3.0 User Guide: Revision 9

Watchmen is a research software application developed by Pacific Northwest National Laboratory (PNNL) that incorporates the scientific and operational expertise for reviewing data from treaty monitoring radionuclide stations. The radionuclide stations are part of the International Monitoring System (IMS), a worldwide network to monitor for nuclear explosions. The data the IMS produces are critical to determine if a radionuclide release event is from a nuclear explosion. Stations deliver their measurements and system status to the International Data Centre (IDC), which forwards it via email to all subscribers. Watchmen is capable of processing data from several radioxenon station types.

97 MATHEMATICS AND COMPUTING↗

LESSONS LEARNED IN AEROSOL MONITORING WITH THE RASA

The Radionuclide Aerosol Sampler/Analyzer (RASA) is an automated aerosol collection and analysis system designed by Pacific Northwest National Laboratory (PNNL) in the 1990's and is deployed in several locations around the world as part of the International Monitoring System (IMS) required under the Comprehensive Nuclear-Test-Ban Treaty (CTBT). The RASA operates unattended, save for regularly scheduled maintenance, iterating samples through a three-step process on a 24-hour interval. In its 15-year history, much has been learned from the operation and maintenance of the RASA that can benefit engineering updates or future aerosol systems. On 11 March 2011, a 9.0 magnitude earthquake and tsunami rocked the eastern coast of Japan, resulting in power loss and cooling failures at the Daiichi nuclear power plants in Fukushima Prefecture. Aerosol collections were conducted with the RASA in Richland, WA. We present a summary of the lessons learned over the history of the RASA, including lessons taken from the Fukushima incident, regarding the RASA IMS stations operated by the United States.

21 SPECIFIC NUCLEAR REACTORS AND ASSOCIATED PLANTS↗

RADIATION DETECTION CHALLENGES

Pacific Northwest National Laboratory (PNNL) is a key part in the international community in the detection of radioxenon. PNNL’s design of radioxenon detection systems have resulted in the need for multiple sources to be capable of producing high quality NaI and CsI well detectors. Testing of NaI and CsI detectors from multiple manufactures has resulted in the discovery of two issues. First, there is potential for a dead layer, due to the manufacturer handling of the crystal, to be present on both the CsI and NaI crystals. The second issue is an energy drift caused by incorrect mating of PMT and PMT base to the crystal. These two issues cause adverse effects on the measurement of radioxenon or any other radiological measurement. It is clear that additional handling and inspection procedures are necessary during the manufacturing process. This paper will discuss the matter in more detail and give evidence of the presence of these issues in PNNL purchased crystals. The paper will also propose procedures for handling and testing to high quality CsI and NaI crystals get delivered on future purchases.

45 MILITARY TECHNOLOGY, WEAPONRY, AND NATIONAL DEF↗

Beowulf - Beta-Gamma Detector Calibration Graphical User Interface

Pacific Northwest National Laboratory (PNNL) has demonstrated significant advancement in using beta-gamma coincidence detectors to detect a wide range of radioxenon isotopes. To obtain accurate activities with the detector it must be properly calibrated by measuring a series of calibration gas samples. The data is analyzed to create the calibration block used in the International Monitoring System file format. Doing the calibration manually has proven to be tedious and prone to errors, requiring a high degree of expertise. The Beowulf graphical user interface (GUI) is a software application that encompasses several components of the calibration task and generates a calibration block, as well as, a detailed report describing the specific calibration process used. This additional document can be used as a Quality assurance certificate to assist in auditing the calibration. This paper consists of two sections. Section 1 will describe the capabilities of Beowulf and section 2 will be a representative report generated or the 137Cs calibration and quality assurance source.

45 MILITARY TECHNOLOGY, WEAPONRY, AND NATIONAL DEF↗

RADIOXENON MEASUREMENTS WITH THE PHOSWATCH DETECTOR SYSTEM

Many of the radioxenon detector systems used in the International Monitoring System and in other applications employ beta/gamma coincidence detection to achieve high sensitivity. In these systems, the coincidence detection is implemented by requiring simultaneous signals from separate beta and gamma detectors. While very sensitive to small amounts of radioxenon, this approach requires careful calibration and gain matching of several detectors and photomultiplier tubes. An alternative approach is the use of a phoswich detector in which beta-gamma coincidences are detected by pulse shape analysis. The phoswich requires only a single photomultiplier tube and thus is easier to set up and calibrate, and can be assembled into a more compact and robust system. In the past, we have developed a COTS detector system, named PhosWatch, which consists of a CsI(Tl)/BC-404 phoswich detector, digital readout electronics, and on-board software to perform the pulse shape analysis. Several units of this system have been manufactured and are now evaluated at several radioxenon research laboratories. In this paper, we will report results from production tests and some of the evaluations, including a side-by-side comparison of a SAUNA detector and a PhosWatch system using atmospheric radioxenon samples. In addition, we will show initial results obtained with a higher speed version of the readout electronics, digitizing at 500 MHz and thus able to better resolve the fast pulses from the BC-404.

45 MILITARY TECHNOLOGY, WEAPONRY, AND NATIONAL DEF↗

Digital Data Acquisition Graphical User Interface

Traditional radioxenon measurements have been done by ground based fixed systems, however in recent years there has been an increased need for systems capable of quick deployment or even complete mobility. Using the Pixie-4 data acquisition (DAQ) system can help reduce the electronics footprint of both current systems, like the radioxenon Radionuclide Laboratory 16 (RL-16) and the Swedish Automatic Unit for Noble Gas Acquisition (SAUNA), as well as future systems. Pacific Northwest National Laboratory (PNNL) has developed a Linux based Nyx graphical user interface (GUI) for Pixie-4 cards. The Nyx software can be installed on various Linux platforms and is written in C++. This software offers a rich user interface for configuring and operating the Pixie4 card and PNNL designed high voltage (HV) cards. Nyx allows one to quickly get a nuclear detector operational by maintaining the core diagnostic features built into the Pixie-4 cards. First, Nyx maintains the multitude of adjustable parameters accessible in the Pixie-4 cards, which allows one to customize settings to take full advantage of a particular detector. Nyx also maintains an oscilloscope feature which is extremely useful to optimize settings and to verify proper detector behavior and is often the first feature used in Nyx during detector setup. Finally, Nyx allows the user to collect data in several formats including full pulse shapes to basic histograms. Overall, it is the corner stone for the transition of beta-gamma systems to a state-of-the-art digitizing DAQ.

45 MILITARY TECHNOLOGY, WEAPONRY, AND NATIONAL DEF↗

Progress in Advanced Spectral Analysis of Radioxenon

Improvements to a Java based software package developed at Pacific Northwest National Laboratory (PNNL) for display and analysis of radioxenon spectra acquired by the International Monitoring System (IMS) are described here. The current version of the Radioxenon JavaViewer implements the region of interest (ROI) method for analysis of beta-gamma coincidence data. Upgrades to the Radioxenon JavaViewer will include routines to analyze high-purity germanium detector (HPGe) data, Standard Spectrum Method to analyze beta-gamma coincidence data and calibration routines to characterize beta-gamma coincidence detectors. These upgrades are currently under development; the status and initial results will be presented. Implementation of these routines into the JavaViewer and subsequent release is planned for FY 2011-2012.

45 MILITARY TECHNOLOGY, WEAPONRY, AND NATIONAL DEF↗

Comparison of near-background concentrations of Argon-37 and Xenon-133 in the Atmosphere

Radioisotopes of noble gases xenon and argon can be important indicators of underground nuclear explosions. The Comprehensive Nuclear-Test-Ban Treaty (CTBT) includes monitoring capabilities to identify potential nuclear explosions conducted in violation of the CTBT. This monitoring currently focuses on measurement of the xenon isotopes 133Xe, 135Xe, 131mXe and 133mXe. However, it is predicted that within 100 days of an underground nuclear explosion (UNE) 37Ar would be released to the atmosphere at higher concentrations than xenon isotopes (Haas et al. 2010) and with a higher signal to background ratio, depending on the radioxenon background levels. Therefore, inclusion of 37Ar measurement capabilities at atmospheric International Monitoring System (IMS) stations may represent an improvement in the capability to detect a nuclear explosion. At an IMS station, it could be difficult to determine what constitutes an elevated concentration as a result of an UNE without first understanding the expected range of background concentrations. This work describes our analysis of atmospheric samples for 37Ar to evaluate the range of background concentrations. Samples were collected at multiple locations, with approximately half coming from a sampler co-located with an IMS xenon monitoring station (RN75). The range of 37Ar concentrations measured in atmospheric air samples was relatively narrow; for samples considered detectable, the minimum and maximum measured concentrations were 0.56 and 2.3 mBq/m3, respectively. Comparison of 37Ar and 133Xe concentrations measured at the IMS station indicated some correlation between the measured concentrations. The results presented here demonstrate the capability to detect background concentrations of 37Ar in atmospheric air and provide a basis for potential implementation of 37Ar monitoring at IMS stations.

Fritz, Brad G.↗