Search NASA⌕ Search

SEARCH · Search NASA

Results for “optical interferometry”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 163 records · Page 9

Multiloop and multiaxis atomtronic Sagnac interferometry

We report the experimental realization of a large-area and multiaxis atomtronic interferometer in an optical waveguide for rotation sensing. A large enclosed area is achieved through multiloop operation in a guided-atom interferometer using Bose-Einstein condensates. We demonstrate a three-loop interferometer with a total interrogation time of ∼ 0.4 s and an enclosed area of 8.7 mm 2 —the largest reported in a fully guided or one-dimensional setup. High-contrast interference fringes are observed for up to five Sagnac orbits in a smaller loop-area configuration. Our approach enables interleaved rotation measurements about multiple arbitrary axes within the same experimental setup. We present results for area-enclosing interferometers in both horizontal and vertical planes, demonstrating that the interferometer contrast remains comparable across orthogonal orientations of the enclosed area vectors.

74 ATOMIC AND MOLECULAR PHYSICS↗

Plasma flows during the ablation stage of an over-massed pulsed-power-driven exploding planar wire array

We characterize the plasma flows generated during the ablation stage of an over-massed exploding planar wire array, fielded on the COBRA pulsed-power facility (1 MA peak current, 250 ns rise time). The planar wire array is designed to provide a driving magnetic field (80–100 T) and current per wire distribution (about 60 kA), similar to that in a 10 MA cylindrical exploding wire array fielded on the Z machine. Over-massing the arrays enables continuous plasma ablation over the duration of the experiment without implosion. The requirement to over-mass on the Z machine necessitates wires with diameters of 75–100μm, which are thicker than wires usually fielded on wire array experiments. To test ablation with thicker wires, we perform a parametric study by varying the initial wire diameter between 33 and 100 μm. The largest wire diameter (100 μm) array exhibits early closure of the cathode-wire gap, while the gap remains open over the duration of the experiment for wire diameters between 33 and 75 μm. Laser plasma interferometry and time-gated extreme-ultraviolet (XUV) imaging are used to probe the plasma flows ablating from the wires. The plasma flows from the wires converge to generate a pinch, which appears as a fast-moving (V≈100kms−1) column of increased plasma density (n¯e≈2×1018cm−3) and strong XUV emission. Finally, we compare the results with three-dimensional resistive-magnetohydrodynamic (MHD) simulations performed using the code GORGON, the results of which reproduce the dynamics of the experiment reasonably well.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Analysis of Pitting Corrosion on Wrought and Additively Manufactured 316L Stainless Steel in Atmospheric Environments

Additive manufacturing of metal components enables rapid fabrication of complex geometries. However, metal additive manufacturing also introduces new morphological and microstructural characteristics which might be detrimental to component performance. Here we report the pitting corrosion properties of wrought and additively manufactured 316L stainless steel after atmospheric exposure to coastal environments and laboratory-created environments. Qualitative visualization in combination with quantitative analysis of resulting pits provided an in-depth understanding of pitting differences between wrought and additively manufactured 316L stainless steel and between coastal and laboratory-based exposure. Optical and scanning electron microscopy were utilized for visualization, while white light interferometry measured pits across approximately 5mm x 5mm areas on each sample. Post-processing of the interferometry data enables quantification of pitting attack for each sample in terms of both pit depth and pit volume. The pitting analysis introduced herein offers a new technique to compare pitting attack between different manufacturing processes and materials.

36 MATERIALS SCIENCE↗

Spectral interferometry-based microwave-frequency vibrometry for integrated acoustic wave devices

Microwave phononics is a promising platform for sensing, computing, and quantum information science; thus, sensitive and high-throughput characterization tools are needed not only for device verification and optimization but also for revealing transient and nonlinear dynamics. Existing interferometric optical vibrometers for 2D mapping are challenged by operating point stabilization, surface reflectivity contrast, and long acquisition time. Here, we use spectral interferometry, which is insensitive to these factors and utilizes a continuous raster scanning scheme for vibration mapping with high throughput. We intensity-modulate our broadband light source with an electro-optic modulator to resolve vibrations at microwave frequencies. Our system requires no fast photodetector or digitizer operating in the microwave frequency range. We image the 1 GHz vibration field of a 300 × 150 µm 2 area of an entire surface acoustic wave device in 10 min with simultaneous surface profilometry. Our system has a vibration sensitivity of 120 fm/sqrt(Hz) and a linear throughput of 0.77 mm/s on the chip surface. The technique offers capabilities for characterizing a wide range of acoustic wave and micromechanical devices to better understand their behavior and performance.

47 OTHER INSTRUMENTATION↗

Determining the tilt of the Raman laser beam using an optical method for atom gravimeters

The tilt of a Raman laser beam is a major systematic error in precision gravity measurement using atom interferometry. The conventional approach to evaluating this tilt error involves modulating the direction of the Raman laser beam and conducting time-consuming gravity measurements to identify the error minimum. In this work, we demonstrate a method to expediently determine the tilt of the Raman laser beam by transforming the tilt angle measurement into characterization of parallelism, which integrates the optical method of aligning the laser direction, commonly used in freely falling corner-cube gravimeters, into an atom gravimeter. A position-sensing detector (PSD) is utilized to quantitatively characterize the parallelism between the test beam and the reference beam, thus measuring the tilt precisely and rapidly. After carefully positioning the PSD and calibrating the relationship between the distance measured by the PSD and the tilt angle measured by the tiltmeter, we achieved a statistical uncertainty of less than 30 µrad in the tilt measurement. Furthermore, we compared the results obtained through this optical method with those from the conventional tilt modulation method for gravity measurement. The comparison validates that our optical method can achieve tilt determination with an accuracy level of better than 200 µrad, corresponding to a systematic error of 20 µGal in g measurement. This work has practical implications for real-world applications of atom gravimeters.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

3D Reconstruction of a High-Energy Diffraction Microscopy Sample Using Multi-modal Serial Sectioning with High-Precision EBSD and Surface Profilometry

High-energy diffraction microscopy (HEDM) combined with in situ mechanical testing is a powerful nondestructive technique for tracking the evolving microstructure within polycrystalline materials during deformation. This technique relies on a sophisticated analysis of X-ray diffraction patterns to produce a three-dimensional reconstruction of grains and other microstructural features within the interrogated volume. However, it is known that HEDM can fail to identify certain microstructural features, particularly smaller grains or twinned regions. Characterization of the identical sample volume using high-resolution surface-specific techniques, particularly electron backscatter diffraction (EBSD), can not only provide additional microstructure information about the interrogated volume but also highlight opportunities for improvement of the HEDM reconstruction algorithms. In this study, a sample fabricated from undeformed “low solvus, high refractory” nickel-based superalloy was scanned using HEDM. The volume interrogated by HEDM was then carefully characterized using a combination of surface-specific techniques, including epi-illumination optical microscopy, zero-tilt secondary and backscattered electron imaging, scanning white light interferometry, and high-precision EBSD. Custom data fusion protocols were developed to integrate and align the microstructure maps captured by these surface-specific techniques and HEDM. The raw and processed data from HEDM and serial sectioning have been made available via the Materials Data Facility (MDF) at https://doi.org/10.18126/4y0p-v604 for further investigation.

36 MATERIALS SCIENCE↗

Reflective binary amplitude grating for soft x-ray shearing and Hartmann wavefront sensing

Here, we demonstrate a reflective wavefront sensor grating suitable for the characterization of high-quality x-ray beamlines and optical systems with high power densities. Operating at glancing incidence angles, the optical element is deeply etched with a two-level pattern of shearing interferometry gratings and Hartmann wavefront sensor grids. Transverse features block unwanted light, enabling binary amplitude in reflection with high pattern contrast. We present surface characterization and soft x-ray reflectometry of a prototype grating array to demonstrate function prior to wavefront measurement applications. A simulation of device performance is shown.

47 OTHER INSTRUMENTATION↗

Optical transparency of LiF (100) shock compressed to ∼360 GPa

High-purity [100] lithium fluoride (LiF) is the most widely used optical window in dynamic compression experiments due to its wide bandgap and well-characterized mechanical response. Recent plate-impact experiments established the [100] LiF Hugoniot to ∼230 GPa and demonstrated shock-induced melting onset at 182 GPa with complete melting by 195 GPa; theoretical models predict LiF optical transparency to nearly 900 GPa. To experimentally examine the optical transparency of [100] LiF at higher pressures and in the liquid state, laser-driven shock experiments were performed at peak stresses ranging from 223 to 363 GPa. Optical response was examined by measuring the particle velocity histories at the Kapton/LiF interface using laser interferometry at 532 and 1550 nm wavelengths; in-material particle velocities were obtained using established refractive-index corrections. Continuous photonic Doppler velocimetry fringes were observed across the entire stress range, demonstrating that LiF remains transparent to 1550 nm light throughout the multi-megabar regime investigated. At 532 nm, fringe visibility depended on the reflector coating: aluminum mirrors provided signals to ∼235 GPa, while gold mirrors extended this limit to 270.5 GPa, indicating that the shorter-wavelength response is likely sensitive to experimental configuration rather than to the loss of LiF transparency. Continued optical transparency to at least 360 GPa indicates that shock-melted LiF does not display bandgap closure over the stress range explored. Furthermore, these results provide direct experimental constraints on the high-pressure optical response and establish LiF (100) as a robust optical window material for laser-driven dynamic compression experiments approaching 400 GPa.

Renganathan, P. [Argonne National Laboratory (ANL)↗

Rapidly tunable ultrabroadband flying focus using adaptive optics and an axiparabola

A programmable ultrabroadband flying focus was produced using adaptive optics and an axiparabola with a continuous wave superluminescent diode. A deformable mirror and spatial light modulator were used to add a programmable amount of radial group delay, and an axiparabola was used to create an extended focus by imparting spherical aberration. Three different flying focus trajectories were measured using spectral interferometry, two with uniform velocity and one with an accelerating velocity. Here, the temporal response function width of the flying focus optics alone was calculated to be 52 ± 6 fs, and the focal spot size was measured to be (1.2 ± 0.1) × larger than the diffraction-limited spot size through the extended focus.

Markland, H. S. [University of Rochester, NY (Unit↗

Coriolis force compensation and laser beam delivery for 100-m baseline atom interferometry

The Coriolis force is a significant source of systematic phase errors and dephasing in atom interferometry and is often compensated by counter-rotating the interferometry laser beam against Earth's rotation. We present a novel method for performing Coriolis force compensation for long-baseline atom interferometry, which mitigates atom-beam misalignment due to beam rotation, an effect which is magnified by the long lever arm of the baseline length. The method involves adjustment of the angle of the interferometer beam prior to a magnifying telescope, enabling the beam to pivot around a tunable position along the interferometer baseline. By tuning the initial atom kinematics and adjusting the angle with which the interferometer beam pivots about this point, we can ensure that the atoms align with the center of the beam during the atom optics laser pulses. This approach will be used in the MAGIS-100 atom interferometer and could also be applied to other long-baseline atom interferometers. An additional challenge associated with long baseline interferometry is that since long-baseline atom interferometers are often located outside of typical laboratory environments, facilities constraints may require lasers to be housed in a climate-controlled room a significant distance away from the main experiment. Nonlinear effects in optical fibers restrict the use of fiber-based transport of the high-power interferometry beam from the laser room to the experiment. We present the design of and prototype data from a laser transport system for MAGIS-100 that maintains robustness against alignment drifts despite the absence of a long fiber.

Glick, Jonah↗

Binary pseudo-random array standards for calibration of 3D optical surface profilers used for metrology with significantly curved x-ray optics

High-accuracy metrology is vitally important in manufacturing ultra-high-quality free-form mirrors designed to manipulate X-ray light with nanometer-scale wavelengths. The current capabilities and possibility for improvements in X-ray mirror manufacturing are limited by inherent imperfections of the integrated metrology tools. In the case of Fizeau interferometry, metrology tools are currently calibrated with super-polished flat test-standard/reference mirrors. This is acceptable for measuring slightly curved X-ray optics. However, for even moderately curved aspherical X-ray mirrors the flat-reference calibration is not sufficiently accurate and stitching Fizeau interferometer-based surface metrology is used to mitigate the problem. But still, the retrace and aberration errors, as well as the limited spatial resolution, described with the instrument transfer function (ITF), can be transferred into the optical surface topography of X-ray mirrors obtained in stitching metrology. For ITF calibration, we have developed an original technique, based on test standards structured as two-dimensional (2D) highly-randomized (HR) binary pseudo-random arrays (BPRAs). The technique employs the unique properties of the HR BPRA patterns in the spatial frequency domain., i.e. the inherent 2D power spectral density of the HR BPRA pattern has a deterministic white-noise-like character that allows direct determination of the ITF with uniform sensitivity over the entire spatial frequency range and field-of-view of an instrument. Here, we explore technological, metrological, and analytical aspects essential for calibration of the retrace and aberration errors of Fizeau interferometers using different types of tilted test samples, including a super-polished reference mirror for the re-trace calibration and the uniformly redundant array (URA) BPRA standards for the geometrical distortion (aberration) calibration. While the first method was previously demonstrated by researchers at DIAMOND Light Source, a method based on the URA BPRA is described and demonstrated here for the first time. We outline the design and fabrication process used in fabrication of URA BPRA test standards, and present the results of application of the URA BPRA standards demonstrating the high efficacy of our approach to geometrical distortion calibration of Fizeau interferometers. We also discuss the possible sources of unexpected peculiarities of the systematic errors, including an astigmatic character of the retrace error, observed with Fizeau interferometers at the Advanced Light Source X-Ray Optics Laboratory.

Munechika, Keiko↗

Laser Speckle Pattern Stability in Hypersonic Regimes for Experimental Mechanics and Metrological Studies

Here, an empirical study assessing the suitability of laser speckle patterns for use in experimental mechanics research conducted at hypersonic conditions is presented. Speckle patterns generated via coherent optical scattering from a gold-coated graphite surface inserted into a Mach 10 air stream were collected and analyzed using Computer-Aided Speckle Interferometry using two methodologies: a typical spanwise approach involving increasing temporal span between image pairs, and a sequential approach that utilizes a combination of temporal re-referencing and spatial resampling. Results were characterized for spatial-temporal stability and variance. Our observations demonstrate that optical methods relying on stable and properly formed speckle patterns can be used in a hypersonic regime at various Reynolds numbers and common camera frame rates, but the technique is sensitive to the conditions of the airflow and the processing methodology chosen.

42 ENGINEERING↗

A versatile high-speed x-ray microscope for sub-10 nm imaging

We have developed a next-generation scanning x-ray microscope RASMI (RApid Scanning Microscopy Instrument) for high-throughput tomographic imaging. RASMI is installed at the hard x-ray nanoprobe beamline at NSLS-II and is capable of manipulating 1D multilayer Laue lenses (MLLs) and 2D optics (both zone plates and monolithically assembled 2D MLLs). The sample scanning stage utilizes line-focusing interferometry as an encoder while performing fly-scanning data acquisition. The system can be configured for both position- and time-triggering modes during fly-scanning. The microscope demonstrated a detector-limited data acquisition rate of 1.25 kHz during ptychography measurements. The initial x-ray results yielded a sample-limited resolution of ∼6 nm in 2D. RASMI can be adopted for in-vacuum applications and is a foundation for the next-generation scanning microscopy systems to be developed and commissioned at NSLS-II.

36 MATERIALS SCIENCE↗

Multifrequency Analysis of Favored Models for the Messier 87* Accretion Flow

Abstract The polarized images of the supermassive black hole Messier 87* (M87*) produced by the Event Horizon Telescope (EHT) provide a direct view of the near-horizon emission from a black hole accretion and jet system. The EHT theoretical analysis of the polarized M87* images compared thousands of snapshots from numerical models with a variety of spins, magnetization states, viewing inclinations, and electron energy distributions, and found a small subset consistent with the observed image. In this article, we examine two models favored by EHT analyses: a magnetically arrested disk with moderate retrograde spin and a magnetically arrested disk with high prograde spin. Both have electron distribution functions that lead to strong depolarization by cold electrons. We ray trace five snapshots from each model at 22, 43, 86, 230, 345, and 690 GHz to forecast future very long baseline interferometry (VLBI) observations and examine limitations in numerical models. We find that even at low frequencies where optical and Faraday rotation depths are large, approximately rotationally symmetric polarization persists, suggesting that shallow depths dominate the polarization signal. However, morphology and spectra suggest that the assumed thermal electron distribution is not adequate to describe emission from the jet. We find 86 GHz images show a ringlike shape determined by a combination of plasma and spacetime imprints, smaller in diameter than recent results from the Global mm-VLBI Array. We find that the photon ring becomes more apparent with increasing frequency, and is more apparent in the retrograde model, leading to large differences between models in asymmetry and polarization structure.

Astronomy & Astrophysics↗

A Range and Performance Optimized Version of the Computer-Aided Speckle Interferometry Algorithm for Real-Time Displacement-Strain Field Monitoring

Abstract This work presents an optimized implementation of the Computer-Aided Speckle Interferometry algorithm which enables full-field determination of displacements and strains on commodity Graphics Processing Units at high resolution and frame rates. By combining careful control of the average speckle size in a laser speckle pattern with a simple sampling rate conversion scheme, a compact representation of the optical speckle is achieved. This allows for optimal use of Graphics Processing Unit architecture with robust range extension. The optimal mapping of the Computer-Aided Speckle Interferometry algorithm to Graphics Processing Unit architecture is shown in detail, and a straightforward method for disambiguating large displacements is illustrated. Lastly, this paper demonstrates a two-step subimage-tapering modification to the original algorithm that enables robust range enhancement while maintaining resolution. Results from numerical simulations on synthetic speckle patterns are shown, and runtime performance metrics are provided, with performance ranging up to 60 frames per second in some cases. The method is suitable for interactive experimental mechanics research, process and testing or any application where real-time high-resolution displacement-strain monitoring is needed. A .NET Framework class library enabling the incorporation of the algorithm into 3rd -party applications is available for download.

42 ENGINEERING↗