Electric Vehicles at Kennedy Space Center

The story of how the transportation office began by introducing low speed electric cars (LSEV) to the fleet managers and employees. This sparked and interest in purchasing some of these LSEV and the usage on KSC. Transportation was approached by a vender of High Speed Electric Vehicle (HSEV) we decided to test the HSEV to see if they would meet our fleet vehicle needs. Transportation wrote a Space Act Agreement (SAA) for the loan of three Lithium Powered Electric vehicles for a one year test. The vehicles have worked very well and we have extended the test for another year. The use of HSEV has pushed for an independent Electric Vehicle Study to be performed to consider ways to effectively optimize the use of electric vehicles in replacement of gasoline vehicles in the KSC vehicle fleet. This will help the center to move closer to meeting the Executive Order 13423.

Chesson, Bruce E.↗

Baseline effects on carbon footprints of biofuels: The case of wood

As biofuel usage has boomed over the past decade, so has research and regulatory interest in its carbon accounting. This paper examines one aspect of that carbon accounting: the baseline, i.e. the reference case against which other conditions or changes can be compared. A literature search and analysis identified four baseline types: no baseline; reference point; marginal fossil fuel; and biomass opportunity cost. The fourth one, biomass opportunity cost, is defined in more detail, because this is not done elsewhere in the literature. The four baselines are then applied to the carbon footprint of a wood-fired power plant. The footprint of the resulting wood-fired electricity varies dramatically, according to the type of baseline. Baseline type is also found to be the footprint's most significant sensitivity. Other significant sensitivities are: efficiency of the power plant; the growth (or re-growth) rate of the forest that supplies the wood; and the residue fraction of the wood. Length of the policy horizon is also an important factor in determining the footprint. The paper concludes that because of their significance and variability, baseline choices should be made very explicit in biofuel carbon footprints. - Highlights: Black-Right-Pointing-Pointer Four baseline types for biofuel footprinting are identified. Black-Right-Pointing-Pointer One type, 'biomass opportunity cost', is defined mathematically and graphically. Black-Right-Pointing-Pointer Choice of baseline can dramatically affect the footprint result. Black-Right-Pointing-Pointer The 'no baseline' approach is not acceptable. Black-Right-Pointing-Pointer Choice between the other three baselines depends on the question being addressed.

54 ENVIRONMENTAL SCIENCES↗

Performance of a Natural Gas Solid Oxide Fuel Cell System With and Without Carbon Capture

The fuel cell program at the United States Department of Energy (DOE) National Energy Technology Laboratory (NETL) is focused on the development of low-cost, highly efficient, and reliable fossil-fuel-based solid oxide fuel cell (SOFC) power systems that can generate environmentally-friendly electric power with at least 90 percent carbon capture. NETL’s SOFC technology development roadmap is aligned with near-term market opportunities in the distributed generation sector to validate and advance the technology while paving the way for utility-scale natural gas (NG)- and coal-derived synthesis gas-fueled applications via progressively larger system demonstrations. The present study represents a part of a series of system evaluations being carried out at NETL to aid in prioritizing technological advances along research pathways to the realization of utility-scale SOFC systems, a transformational goal of the fuel cell program. In particular, the system performance of utility-scale NG fuel cell (NGFC) systems with and without carbon dioxide (CO2) capture is presented. The NGFC system analyzed features an external auto-thermal reformer (ATR) feeding the fuel to the SOFC system consisting of planar anode-supported SOFC with separated anode and cathode off-gas streams. In systems with CO2 capture, an air separation unit (ASU) is used to provide the oxygen for the ATR and for the combustion of unutilized fuel in the SOFC anode exhaust along with a CO2 purification unit to provide a nearly pure CO2 stream suitable for transport for usage in enhanced oil recovery operations or for storage in underground saline formations. Remaining thermal energy in the exhaust gases is recovered in a bottoming steam Rankine cycle while supplying any process heat requirements. A reduced order model (ROM) developed at the Pacific Northwest National Laboratory (PNNL) is used to predict the SOFC performance. The ROM, while being computationally effective for system studies, provides other detailed information about the state of the stack, such as the internal temperature gradient, generally not available from simple performance models often used to represent the SOFC. Such additional information can be important in system optimization studies to preclude operation under off-design conditions that can adversely impact overall system reliability. The NGFC system performance was analyzed by varying salient system parameters, including the percent of internal (to the SOFC module) NG reformation—ranging from 0 to 100 percent—fuel utilization, and current density. The impact of advances in underlying SOFC technology on electrical performance was also explored.

solid oxide fuel cell (SOFC), natural gas fuel cel↗

Conversion of food waste to renewable energy: A techno-economic and environmental assessment

Increasing quantities of food waste have become a concern due to high disposal costs in landfills and high greenhouse gas emissions. With this increase in food waste generation, there is also an increasing demand for renewable natural gas to supplement traditional fossil fuel combustion and offset the impacts of climate change. Collecting food waste from landfills and turning it into renewable natural gas using anaerobic digestion could be a win-win option for both food waste disposal and renewable energy production. While some literature exists on the energy potential, economic feasibility, and environmental benefit of food waste disposal via anaerobic digestion, no existing study simultaneously evaluates the energy, economic and environmental effect of food waste to renewable energy via anaerobic digestion, especially on a plant and city scale. Further, this study is focused on the techno-economic and environmental assessment of food waste to energy via anaerobic digestion in order to fill this gap. Four anaerobic digestion pathways are considered in this study: flare, pipeline natural gas, combined heat and power, and combined cycle for efficient power generation. Using a city of 1M people the results show that renewable natural gas from food waste could supply the natural gas usage for 1.9% of residential use, 2.7% of commercial use, 1.1% of industrial use, 167.5% of the compressed natural gas vehicle fleet, 0.7% of electric power generation, or 2.5% of industrial high-temperature heating processes. All pathways except pipeline natural gas will have a positive net present value in the baseline scenario, and the pipeline natural gas pathway will become economically viable with a net present value of 31 USD/t of food waste with renewable energy credits. Lastly, all of the pathways achieve negative greenhouse gas emissions, which indicates that anaerobic digestion is a more environmentally friendly method for the handling of food waste than landfills.

03 NATURAL GAS↗

Strategic Energy Management Plan for the Santa Ynez Band of Chumash Indians

This plan outlines the Santa Ynez Band of Chumash Indians’ comprehensive energy management strategy including an assessment of current practices, a commitment to improving energy performance and reducing overall energy use, and recommended actions to achieve these goals. Vision Statement: The primary objective of the Strategic Energy Management Plan is to implement energy efficiency, energy security, conservation, education, and renewable energy projects that align with the economic goals and cultural values of the community to improve the health and welfare of the tribe. The intended outcomes of implementing the energy plan include job creation, capacity building, and reduced energy costs for tribal community members, and tribal operations. By encouraging energy independence and local power production the plan will promote self-sufficiency. Mission & Objectives: The Strategic Energy Plan will provide information and suggestions to guide tribal decision-making and provide a foundation for effective management of energy resources within the Santa Ynez Band of Chumash Indians (SYBCI) community. The objectives of developing this plan include; Assess current energy demand and costs of all tribal enterprises, offices, and facilities; Provide a baseline assessment of the SYBCI’s energy resources so that future progress can be clearly and consistently measured, and current usage better understood; Project future energy demand; Establish a system for centralized, ongoing tracking and analysis of tribal energy data that is applicable across sectors, facilities, and activities; Develop a unifying vision that is consistent with the tribe’s long-term cultural, social, environmental, and economic goals; Identify and evaluate the potential of opportunities for development of long-term, cost effective energy sources, such as renewable energy, energy efficiency and conservation, and other feasible supply- and demand-side options; and Build the SYBCI’s capacity for understanding, managing, and developing energy resources by identifying training, distribution of information materials, and community meeting needs and opportunities

29 ENERGY PLANNING, POLICY, AND ECONOMY↗

A Sustainable Wind–Biogas Hybrid System for Remote Areas in Jordan: A Case Study of Mobile Hospital for a Zaatari Syrian Refugee Camp

Access to reliable and sustainable energy in remote areas remains a pressing global challenge, significantly affecting economic development and the quality of life. This study focuses on the implementation of fully off-grid wind–biogas hybrid power systems to address this issue, with a focus on remote healthcare camp facilities. This paper investigates the performance of a hybrid renewable energy system within the context of one of Jordan’s northern remote areas, the Zaatari Syrian Refugee Camp, assessing its efficiency and environmental impact by taking the Zaatari hospital as the case study. Simulations were conducted to evaluate system components, including wind turbines, biogas generators, and diesel generators. A comprehensive evaluation was conducted, encompassing both the operational efficiency of the system and its impact on the environment. This study also considered various scenarios (SC#), including grid availability and autonomy levels, to optimize system configurations. The techno-economic assessment employed the levelized cost of energy (LCOE) as a key performance indicator, and sensitivity analyses explored the impact of diesel costs and wind power fluctuations on the system. Additionally, environmental assessment was conducted to evaluate the environmental effects of hybrid systems, with a specific focus on reducing greenhouse gas emissions. This investigation involved an examination of emissions in three different scenarios. The results indicate that the lowest LCOE that could be achieved was 0.0734 USD/kWh in SC#1 with 72.42% autonomy, whereas achieving 100% autonomy increased the LCOE to 0.1756 USD/kWh. Additionally, the results reveal that in scenarios SC#2 and SC#3, which have a higher proportion of diesel generator usage, there were elevated levels of NO x and CO 2 emissions. Conversely, in SC#1, which lacks diesel generators, emissions were notably lower. The proposed hybrid system demonstrates its potential to provide a reliable energy supply to healthcare facilities in remote regions, emphasizing both economic feasibility and environmental benefits. These findings contribute to informed decision making for sustainable energy solutions in similar contexts, promoting healthcare accessibility and environmental sustainability.

09 BIOMASS FUELS↗

HybridSystemsSimulations.jl - Solving the Merchant Collocated Facilities with JuMP

The development of new clean-generation technologies also leads to new plant-level architectures that combine several generation and storage assets behind the point of connection. These co-located generation resources (Hybrid Systems) primarily operate as merchant assets that employ automated market bidding models and internal Energy Management Systems (EMS) to comply with the operator's signals. Formulating an optimal bidding model requires embedding the EMS control model into the bidding algorithm, resulting in a bi-level optimization problem. In this presentation, we first showcase using JuMP to formulate and solve this problem effectively for multiple merchant systems and the bidding outcomes considering different model formulations. Second, the bidding outcomes are later integrated into a PowerSimulations.jl (also built with JuMP) simulation to study the system-level effects of the various merchant bidding and the interactions between market-clearing models and the embedded EMS model. We will showcase simulations conducted in the RTS system considering different levels of merchant hybrid systems participation. The presentation provides the following specific insights on JuMP usage: 1) the Formulation of specialized bi-level problems with custom cuts to solve the merchant hybrid system bidding problem; 2) the integration of a modular model within a complex simulation workflow supported by JuMP in PowerSimulations.jl; 3) Accelerating the solution of power systems operations simulation that employ agent optimization problems using JuMP.

energy markets↗

Multiphase Nano-Composite Coatings for Achieving Energy Optimization

UES Inc. and ANL teamed in this work to develop novel coating systems for the protection of surfaces from thermal degradation mainly in two applications; Machining and Die casting. These coatings were specifically designed for the purpose by incorporating required material phases and the overall architecture, which led to reduce the energy usage and increase efficiency of the operations. Following the UES/ANL's feasibility work, the coatings were developed utilizing High power impulse magnetron sputtering (HiPMS) and Large area filtered arc deposition (LAFAD) techniques. Toughness, hardness and oxidation resistance: contrasting qualities have been mixed in the right proportion to attain the suitable material characteristic for the cause. Hafnium diboride (HfB 2 ) based materials provided such a system and its properties were tamed to attain the right combination of toughness and hardness by working on the microstructure and architecture of coatings. An effective interfacing material (graded concentrations of topcoat) was also achieved in this work to provide the required adhesion between the substrate and the coating. Combination of an appropriate bond coat and a functional top coat provided the present thermal degradation resistant coating for cutting tools and die-casting applications. Laboratory level performance tests and industrial level application tests by partner companies (Beta Site Testing) were used for the development of these coatings.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Experimental Characterization of High-Surface Area Thermal Energy Storage

There is growing interest in energy storage technologies due to the expansion of renewable energy sources that are inherently intermittent and the increasing frequency of extreme weather events that disturb the power grid. Power consumption in buildings makes up approximately 76% of all electricity usage on the grid and is primarily used for thermal applications such as space conditioning, hot water, and cooking. This makes thermal energy storage (TES) an ideal solution for many of these applications. Many TES technologies rely on latent energy storage, which utilizes the melting/solidification of phase change materials (PCM) to store energy. Typically, TES designs suffer from low power density due to their low inherent thermal conductivity. This limitation makes the deployment of TES in active applications difficult as the ease of access to energy is essential for effective use. Common routes for improving power density include high thermal conductivity additives or extended features such as fins that increase cost. This study presents an alternative approach to improving performance through increasing the overall surface area to volume ratio of the device, to increase the available area for convection to occur between the working fluid and PCM. In the study a commercial PCM was selected with a transition temperature ideal for space heating applications. The heat exchanger design utilizes a unique application of triply periodic minimal surfaces (TPMS) for macro-encapsulation of the PCM. The use of TPMS for heat exchangers has been growing in interest due to their high-surface area to volume ratios, which were previously unmanufacturable until the development of additive manufacturing. A modular system was designed and manufactured with a stereolithography resin printing system that is then backfilled with PCM. An experiment test set-up is designed to test the charge and discharge performance of the thermal storage using a conditioned air stream. The pressure drop of the design is tested across a variety of flow rates. When compared to existing experimental data within literature, there is excellent agreement based on the Reynolds number at similar hydraulic diameters. Several inlet temperatures are tested at consistent temperature differences from the phase change temperature for both charging and discharging. Additionally, the volumetric flow rate is varied for each temperature set point. It was found that increasing flow rate had diminishing returns in reducing the overall charge time of the TES. The temperature delta from the melting temperature was the primary contributor to the change in average heat flux with limited variation in average heat transfer rate between charging and discharging at similar inlet temperatures and flow rates. The TPMS heat exchanger design has a high air-side pressure drop but it provides high heat transfer rates. This helps maintain a high outlet temperature during discharge, which is important to thermal comfort applications. The design, manufacturing, and experimental characterization of the TES device will be presented as part of this study.

25 ENERGY STORAGE↗

Simple Cell Balance Circuit

A method has been developed for continuous cell voltage balancing for rechargeable batteries (e.g. lithium ion batteries). A resistor divider chain is provided that generates a set of voltages representing the ideal cell voltage (the voltage of each cell should be as if the cells were perfectly balanced). An operational amplifier circuit with an added current buffer stage generates the ideal voltage with a very high degree of accuracy, using the concept of negative feedback. The ideal voltages are each connected to the corresponding cell through a current- limiting resistance. Over time, having the cell connected to the ideal voltage provides a balancing current that moves the cell voltage very close to that ideal level. In effect, it adjusts the current of each cell during charging, discharging, and standby periods to force the cell voltages to be equal to the ideal voltages generated by the resistor divider. The device also includes solid-state switches that disconnect the circuit from the battery so that it will not discharge the battery during storage. This solution requires relatively few parts and is, therefore, of lower cost and of increased reliability due to the fewer failure modes. Additionally, this design uses very little power. A preliminary model predicts a power usage of 0.18 W for an 8-cell battery. This approach is applicable to a wide range of battery capacities and voltages.

Johnson, Steven D.↗

Automation and Use of Robotics for Decommissioning Tasks - 18322

Decommissioning across the globe is being executed largely by manual labor. The Organization for Economic Co-operation and Development (OECD) has concluded that the nuclear industry has not fully exploited or implemented current technological capabilities, and relies on sometimes outdated technology to perform decommissioning tasks [1]. To address this issue, EPRI recently published the report Evaluation of System Automation and Robotics for Decommissioning Applications (EPRI 3002010599) [2]. To facilitate wide usage of the guidance by technology developers, the report is publicly available at no cost. The use of more efficient and effective decommissioning technologies and processes could reduce the decommissioning project schedule and therefore reduce the period-dependent costs incurred throughout the decommissioning project. Such systems may also offer a substantial benefit with respect to worker safety and radiation exposure reduction. However, tasks for which use of such systems is beneficial must be carefully considered, being robust and generally trouble free to operate in the demanding environment of commercial power plant decommissioning. A review of the major tasks involved in the decommissioning of a nuclear power plant is presented, with a critical assessment of the benefits for the use of robotics and/or automation. Recommendations for areas of future research and development are identified. The results of this project will be beneficial to global organizations working on development of engineered systems for decommissioning applications by providing a focus on priority tasks. (authors)

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Object Proxy Patterns for Accelerating Distributed Applications

Workflow and serverless frameworks have empowered new approaches to distributed application design by abstracting compute resources. However, their typically limited or one-size-fits-all support for advanced data flow patterns leaves optimization to the application programmer—optimization that becomes more difficult as data become larger. The transparent object proxy, which provides wide-area references that can resolve to data regardless of location, has been demonstrated as an effective low-level building block in such situations. Here we propose three high-level proxy-based programming patterns—distributed futures, streaming, and ownership—that make the power of the proxy pattern usable for more complex and dynamic distributed program structures. We motivate these patterns via careful review of application requirements and describe implementations of each pattern. As a result, we evaluate our implementations through a suite of benchmarks and by applying them in three meaningful scientific applications, in which we demonstrate substantial improvements in runtime, throughput, and memory usage.

Distributed Computing↗

A Framework for Integrating Quantum Simulation and High Performance Computing

Scientific applications are starting to explore the viability of quantum computing. This exploration typically begins with quantum simulations that can run on existing classical platforms, albeit without the performance advantages of real quantum resources. In the context of high-performance computing (HPC), the incorporation of simulation software can often take advantage of the powerful resources to help scale-up the simulation size. The configuration, installation and operation of these quantum simulation packages on HPC resources can often be rather daunting and increases friction for experimentation by scientific application developers. We describe a framework to help streamline access to quantum simulation software running on HPC resources. This includes an interface for circuit-based quantum computing tasks, as well as the necessary resource management infrastructure to make effective use of the underlying HPC resources. The primary contributions of this work include a classification of different usage models for quantum simulation in an HPC context, a review of the software architecture for our approach and a detailed description of the prototype implementation to experiment with these ideas using two different simulators (TNQVM & NWQ-Sim). We include initial experimental results running on the Frontier supercomputer at the Oak Ridge Leadership Computing Facility (OLCF) using a synthetic workload generated via the SupermarQ quantum benchmarking framework.

Shehata, Amir [ORNL] (ORCID:0000000224531426)↗

Advanced Microturbine Systems

In July 2000, the United Technologies Research Center (UTRC) was one of five recipients of a US Department of Energy contract under the Advanced Microturbine System (AMS) program managed by the Office of Distributed Energy (DE). The AMS program resulted from several government-industry workshops that recognized that microturbine systems could play an important role in improving customer choice and value for electrical power. That is, the group believed that electrical power could be delivered to customers more efficiently and reliably than the grid if an effective distributed energy strategy was followed. Further, the production of this distributed power would be accomplished with less undesirable pollutants of nitric oxides (NOx) unburned hydrocarbons (UHC), and carbon monoxide (CO). In 2000, the electrical grid delivered energy to US customers at a national average of approximately 32% efficiency. This value reflects a wide range of powerplants, but is dominated by older, coal burning stations that provide approximately 50% of US electrical power. The grid efficiency is also affected by transmission and distribution (T&D) line losses that can be significant during peak power usage. In some locations this loss is estimated to be 15%. Load pockets can also be so constrained that sufficient power cannot be transmitted without requiring the installation of new wires. New T&D can be very expensive and challenging as it is often required in populated regions that do not want above ground wires. While historically grid reliability has satisfied most customers, increasing electronic transactions and the computer-controlled processes of the 'digital economy' demand higher reliability. For them, power outages can be very costly because of transaction, work-in-progress, or perishable commodity losses. Powerplants that produce the grid electrical power emit significant levels of undesirable NOx, UHC, and CO pollutants. The level of emission is quoted as either a technology metric or a system-output metric. A common form for the technology metric is in the units of PPM {at} 15% O2. In this case the metric reflects the molar fraction of the pollutant in the powerplant exhaust when corrected to a standard exhaust condition as containing 15% (molar) oxygen, assuring that the PPM concentrations are not altered by subsequent air addition or dilution. Since fuel combustion consumes oxygen, the output oxygen reference is equivalent to a fuel input reference. Hence, this technology metric reflects the moles of pollutant per mole of fuel input, but not the useful output of the powerplant-i.e. the power. The system-output metric does embrace the useful output and is often termed an output-based metric. A common form for the output-based metric is in the units of lb/MWh. This is a system metric relating the pounds of pollutant to output energy (e.g., MWh) of the powerplant.

01 COAL, LIGNITE, AND PEAT↗

Thermal Assessment and In-Situ Monitoring of Insulated Gate Bipolar Transistors in Power Electronic Modules: Preprint

Insulated gate bipolar transistor (IGBT) power modules are devices commonly used for switching of high voltages and currents. Usage and environmental conditions can cause these power modules to degrade over time, and this gradual process may eventually lead to catastrophic failure of the device. This degradation process may cause some early performance symptoms related to the state of health of the power module, making it possible to detect reliability degradation of the IGBT module. Testing can be used to accelerate this process, permitting a rapid determination of whether specific declines in device reliability can be characterized. In this study, thermal cycling was conducted on multiple power modules simultaneously in order to assess the effect of thermal cycling on the degradation of the power module. In-situ monitoring of temperature was performed from inside each power module using high temperature thermocouples. Device imaging and characterization was performed along with temperature data analysis, to assess failure modes and mechanisms within the power modules. While the experiment was aimed to assess the potential damage effects of thermal cycling on die attach, results indicated that wirebond degradation was the life limiting failure mechanism.

33 ADVANCED PROPULSION SYSTEMS↗

Towards reverse mode automatic differentiation of Kokkos-based codes

Derivative computation is a key component of optimization, sensitivity analysis, uncertainty quantification, and the solving of nonlinear problems. Automatic differentiation (AD) is a powerful technique for evaluating such derivatives, and in recent years, has been integrated into programming environments such as Jax, PyTorch, and TensorFlow to support derivative computations needed for training of machine learning models, facilitating wide-spread use of these technologies. The C++ language has become the de facto standard for scientific computing due to numerous factors, yet language complexity has made the wide-spread adoption of AD technologies for C++ difficult, hampering the incorporation of powerful differentiable programming approaches into C++ scientific simulations. This is exacerbated by the increasing emergence of architectures, such as GPUs, with limited memory capabilities and requiring massive thread-level concurrency. C++ AD tools must effectively use these environments to bring novel scientific simulations to next-generation DOE experimental and observational facilities. In this project, we investigated source transformation-based automatic differentiation using LLVM compiler infrastructure to automatically generate portable and efficient gradient computations of Kokkos-based code. We have demonstrated that our proposed strategy is feasible by investigating the usage of a prototype LLVM-based source transformation tool to generate gradients of simple functions made of sequences of simple Kokkos parallel regions. Speedups of up to 500x compared to Sacado were observed on NVIDIA V100 GPU.

97 MATHEMATICS AND COMPUTING↗

Exploring Building Retrofit Strategies Using AutoBEM Under Future Weather Scenarios

This study evaluates the long-term effectiveness of energy conservation measures (ECMs) on building energy consumption using AutoBEM, a scalable modeling framework driven by the high-resolution Model America dataset. We simulated 18,951 buildings in Flagstaff, Arizona under four climate scenarios using Future Typical Meteorological Year (fTMY) weather files for six time periods spanning from 1980 to 2099. Six ECMs were analyzed across electricity and gas usage, including HVAC fuel-switching, insulation upgrades, and infiltration control. While some measures, such as reducing space infiltration by percentage, showed minimal or even negative impact on total energy savings at the aggregate level, they proved highly effective for specific building types. Conversely, HVAC electrification offers high gas reduction but shifts demand to electricity, highlighting critical trade-offs under different climate trajectories. Building-type-specific analysis under SSP5-RCP8.5 (2080–2099) revealed significant variation in ECM performance, underscoring the need for targeted retrofit strategies. This study demonstrates the power of combining fTMY projections with large-scale simulations to inform data-driven retrofit planning.

Chowdhury, Shovan [ORNL]↗

Use and Siting of Electric Vehicle Charging Stations in Juneau, Alaska

This report details a study of electric vehicle (EV) Level 2 charging stations in Juneau, Alaska. Utilization analyses of six public over five years and 250 residential chargers over two years are included, and a composite score is introduced to identify optimal locations for future charging stations that target residents of manufactured and multifamily housing (MMFH) in Juneau. We find that public charging station usage is very location-dependent, with three chargers in use more than 60% of days during the peak hour of the day (which ranges from 10 a.m. to 7 p.m.), including a charger near residential housing, illuminating potential needs for additional public chargers in those areas. Residential charging utilization typically occurs overnight - opposite to most public charging stations analyzed - and spikes after 10 p.m. This suggests that Alaska Electric Light & Power Company's time-of-use charging program, which lowers electricity rates at 10 p.m. to incentivize overnight charging, is very effective. Residential charging data also show that households tend to charge 15 hours per week, or 9% of the time, meaning that multiple households could likely share one charger if one were provided near MMFH locations. This is supported by residential charging session analysis, which shows that the median household has around two night charging sessions per week. The EV siting analysis identifies areas of high housing density, low access to public chargers, and unconstrained feeders. A cluster of MMFH parcels in Douglas demonstrated the highest composite scores considering all factors, being the only area to have a perfect score of 2.25.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗