Search NASA⌕ Search

SEARCH · Search NASA

Results for “reflectance calibration”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 163 records · Page 9

Suomi NPP VIIRS Solar Diffuser Screen Transmittance Model and Its Applications

The visible infrared imaging radiometer suite on the Suomi National Polar-orbiting Partnership satellite calibrates its reflective solar bands through observations of a sunlit solar diffuser (SD) panel. Sunlight passes through a perforated plate, referred to as the SD screen, before reaching the SD. It is critical to know whether the SD screen transmittance measured prelaunch is accurate. Several factors such as misalignments of the SD panel and the measurement apparatus could lead to errors in the measured transmittance and thus adversely impact on-orbit calibration quality through the SD. We develop a mathematical model to describe the transmittance as a function of the angles that incident light makes with the SD screen, and apply the model to fit the prelaunch measured transmittance. The results reveal that the model does not reproduce the measured transmittance unless the size of the apertures in the SD screen is quite different from the design value. We attribute the difference to the orientation alignment errors for the SD panel and the measurement apparatus. We model the alignment errors and apply our transmittance model to fit the prelaunch transmittance to retrieve the "true" transmittance. To use this model correctly, we also examine the finite source size effect on the transmittance. Furthermore, we compare the product of the retrieved "true" transmittance and the prelaunch SD bidirectional reflectance distribution function (BRDF) value to the value derived from on-orbit data to determine whether the prelaunch SD BRDF value is relatively accurate. The model is significant in that it can evaluate whether the SD screen transmittance measured prelaunch is accurate and help retrieve the true transmittance from the transmittance with measurement errors, consequently resulting in a more accurate sensor data product by the same amount.

sensors↗

MODIS Solar Diffuser Degradation Determination and Its Spectral Dependency

This study presents a modeling approach to improve solar diffuser (SD) degradation determination from SD stability monitor (SDSM) measurements. The MODIS instrument uses a SDto calibrate its reflective solar bands (RSBs) on-orbit. Due to the imperfectly designed SDSM sun view screen, the SD reflectance tracked by SDSM has large noise. The SDSM measurements noise is spectrally coherent and can be minimized by normalizing measurements to the least degradeddetector 9 (936 nm). In this study, a SD degradation model is used to determine the SDdegradation's wavelength dependency and the detector 9 degradation is estimated by the model solution.The results show the SD degradations measured at 6 SDSM detectors (554 _ 936 nm) have stable relationships, where the degradation is inversely proportion to 1/wavelength^4. The model estimated SD degradation at SDSM detector 9 wavelength (936 nm) is ~0.9% from 2002 to 2018.Based on the SD degradation model solution, the SD degradation at short/mid wave bands are estimated to improve short/mid wave bands calibration. The model can also be used to improve interpolating SD degradation at SDSM detectors to RSB wavelengths. Compared to linear interpolation, bands 9 and 10 show the largest differences of up to 0.3 and 0.4% respectively. These differences directly impact the calibration coefficients of these bands.

radiometric calibration↗

Performance of NOAA-20 VIIRS Solar Diffuser and Solar Diffuser Stability Monitor

Visible Infrared Imaging Radiometer Suite (VIIRS) radiometrically calibrates its reflective solar bands (RSBs) primarily through a sunlit onboard solar diffuser (SD). The sunlit SD provides a known radiance under the condition that the absolute product of the SD screen transmittance and the bidirectional reflectance distribution function (BRDF) along the SD-to-telescope direction is accurately known. The BRDF changes due to solar exposure. The change, referred to as the H-factor, is monitored by the onboard SD stability monitor (SDSM). The accuracy of the retrieved H-factor propagates to the retrieved F-factor which corrects the scene spectral radiance. High accuracy of the retrieved H-factor relies on high accuracies in the SDSM screen relative effective transmittance and the relative product of the SD screen effective transmittance and the BRDF at the mission start, and a high SDSM detector signal-to-noise ratio (SNR). This article briefly reviews the algorithms used for the NOAA-20 (N20) VIIRS RSB on-orbit radiometric calibration. Additionally, we show the performance of the N20 VIIRS SDSM, giving the SDSM detector SNRs and the SDSM detector gain temporal changes. We develop a model for the SNRs. The model shows that the decreased SNRs in time are due to the detector gain decreases. We also show the N20 VIIRS SD on-orbit performance, measured by the retrieved H-factor and the estimated standard deviation of its error. The H-factor for the telescope view is obtained from the H-factor for the SDSM view, multiplied by an H-factor angular dependence term. We use an innovative method to determine the angular dependence, using the dependence obtained for the Suomi National Polar-orbiting Partnership (SNPP) VIIRS.

VIIRS↗

Improvements of VIIRS and MODIS Solar Diffuser and Lunar Calibration

Both VIIRS and MODIS instruments use solar diffuser (SD) and lunar observations to calibrate their reflective solar bands (RSB). A solar diffuser stability monitor (SDSM) is used to track the SD on-orbit degradation. On-orbit observations have shown similar wavelength-dependent SD degradation (larger at shorter VIS wavelengths) and SDSM detector response degradation (larger at longer NIR wavelengths) for both VIIRS and MODIS instruments. In general, the MODIS scan mirror has experienced more degradation in the VIS spectral region whereas the VIIRS rotating telescope assembly (RTA) mirrors have seen more degradation in the NIR and SWIR spectral region. Because of this wavelength dependent mirror degradation, the sensor's relative spectral response (RSR) needs to be modulated. Due to differences between the solar and lunar spectral irradiance, the modulated RSR could have different effects on the SD and lunar calibration. In this paper, we identify various factors that should be considered for the improvements of VIIRS and MODIS solar and lunar calibration and examine their potential impact. Specifically, we will characterize and assess the calibration impact due to SD and SDSM attenuation screen transmission (uncertainty), SD BRF uncertainty and onorbit degradation, SDSM detector response degradation, and modulated RSR resulting from the sensor's optics degradation. Also illustrated and discussed in this paper are the calibration strategies implemented in the VIIRS and MODIS SD and lunar calibrations and efforts that could be made for future improvements.

VIIRS↗

Response Versus Scan-Angle Assessment of MODIS Reflective Solar Bands in Collection 6.1 Calibration

The Moderate Resolution Imaging Spectroradiometer (MODIS) instruments onboard the Aqua and Terra satellites have been operated for nearly two decades, producing high-quality earth observation data sets suitable for a broad range of scientific studies regarding the earth’s land, ocean, and atmospheric processes. The high radiometric accuracy of MODIS reflective solar band (RSB) calibration has also served as benchmark measurements for on-orbit cross-calibration studies. As the two MODIS instruments have operated well beyond their design lifespan of six years, the measurements from the onboard calibrators alone become inadequate to characterize the sensor’s response at all scan angles, as evinced by long-term drifts observed at certain scan positions of the Aqua-MODIS 0.64- and 0.86-μm bands in Collection 6 (C6) data set. The latest MODIS Level 1B C6.1 data set incorporates earth-view response trending from invariant desert sites as supplemental inputs to characterize the scan-angle calibration dependencies for all RSB. This article presents a deep convective cloud (DCC)-based calibration approach for an independent evaluation of the MODIS RSB response versus scan-angle (RVS) performance in C6.1. The long-term calibration stability and RVS differences in C6.1 have been significantly improved for Aqua-MODIS RSB. The observed RVS differences of more than 2% in Aqua-MODIS C6 bands 1 and 2 have been reduced to within 1% in C6.1. Some RSBs of Terra-MODIS have suffered temporal drifts up to ~2% and calibration shifts up to 3%, particularly around 2016 when the Terra satellite entered into safe mode. The DCC approach has been found very effective in tracking the on-orbit RVS changes over time.

Clouds and the Earth’s Radiant Energy System (CERE↗

Comparison of MODIS Solar Diffuser Stability Monitor Calibration Results for Different Operational Configurations

The MODIS instruments on the Terra and Aqua spacecraft use a sunlit solar diffuser (SD), with an optional SD attenuation screen (SDS), to calibrate the reflective solar bands. A solar diffuser stability monitor (SDSM) is used to track the SD reflectance degradation on orbit, by taking a ratio of the detector response when viewing the SD compared to the response when viewing the sun. The MODIS SDSMs have been operated both with and without the SDS in place. The SDSMs have also been operated in both a fixed and an alternating mode. In the alternating mode, the SDSM detectors view the SD, sun, and a dark background in an alternating pattern with the view changing on every MODIS scan within a single orbit. In the fixed mode, the SDSM detectors are fixed on the sun view for one orbit, and then are fixed on the SD view for the following orbit. This paper reviews the history of the SDSM operational configurations used throughout the MODIS missions and discusses the differences in the SD degradation results, which may be due to differences in sun-satellite geometry, SD signal level, and stray light effects. We highlight Aqua SDSM results from two recent dates in October 2017 and July 2019, where both the fixed and alternating mode calibrations were run on the same day, providing clear examples of the calibration differences. Additionally, we show how mixing the results from calibrations done with and without the SDS for Aqua MODIS can provide more stable results.

Twedt, Kevin A.↗

Characterization of Clouds and the Anisotropy of Emitted and Reflected Radiances for the Purpose of Obtaining the Radiative Heating of the Atmosphere

The goal of the work supported through this grant was to assess the validity of the assumptions underlying the CERES Strategy for determining radiative fluxes. Specifically, the work focused on the determination of scene type and the use of anisotropic factors to derive radiative fluxes from observed broadband radiances. The work revealed a dependence of the anisotropy of reflected and emitted broadband radiances on the spatial resolution of the observations that had been overlooked in the formulation of the CERES strategy. This dependence on spatial resolution coupled with errors in scene identification led to view zenith angle dependent biases in the ERBE derived radiative fluxes. Scene identification will be greatly improved in CERES thereby alleviating somewhat the biases arising from the dependence of the anisotropy of the radiances on spatial resolution. Attention was then focused on the validity of plane-parallel radiative transfer theory which is relied on to characterize the scene types viewed by the CERES scanner. Again, viewing geometry dependent biases were found even for single-layered, overcast cloud systems. Such systems are taken to be the closest examples of plane-parallel clouds. At least some of the departures from plane-parallel behavior were evidently due to relatively small bumps on the tops of extensive stratus layers. The bumps cannot be resolved in the imagery that will be used to characterize the scenes viewed by the CERES scanner. As part of this investigation, the ice sheets of Greenland and Antarctica were shown to provide radiometrically stable targets for determining the visible and near infrared calibrations of radiometers. These targets were used to calibrate the reflected sunlight at visible wavelengths used in this study. Finally, the limitations of plane-parallel theory notwithstanding, the common practice of ignoring fractional cloud cover within the fields of view of imaging radiometers was shown to lead to biases in the retrieved cloud properties. The development of retrievals for pixel-scale cloud cover fraction is an attempt to reduce such bases. Work on these retrievals continues.

Coakley, James A., Jr.↗

Arctic sea ice albedo from AVHRR

The seasonal cycle of surface albedo of sea ice in the Arctic is estimated from measurements made with the Advanced Very High Resolution Radiometer (AVHRR) on the polar-orbiting satellites NOAA-10 and NOAA-11. The albedos of 145 200-km-square cells are analyzed. The cells are from March through September 1989 and include only those for which the sun is more than 10 deg above the horizon. Cloud masking is performed manually. Corrections are applied for instrument calibration, nonisotropic reflection, atmospheric interference, narrowband to broadband conversion, and normalization to a common solar zenith angle. The estimated albedos are relative, with the instrument gain set to give an albedo of 0.80 for ice floes in March and April. The mean values for the cloud-free portions of individual cells range from 0.18 to 0.91. Monthly averages of cells in the central Arctic range from 0.76 in April to 0.47 in August. The monthly averages of the within-cell standard deviations in the central Arctic are 0.04 in April and 0.06 in September. The surface albedo and surface temperature are correlated most strongly in March (R = -0.77) with little correlation in the summer. The monthly average lead fraction is determined from the mean potential open water, a scaled representation of the temperature or albedo between 0.0 (for ice) and 1.0 (for water); in the central Arctic it rises from an average 0.025 in the spring to 0.06 in September. Sparse data on aerosols, ozone, and water vapor in the atmospheric column contribute uncertainties to instantaneous, area-average albedos of 0.13, 0.04, and 0.08. Uncertainties in monthly average albedos are not this large. Contemporaneous estimation of these variables could reduce the uncertainty in the estimated albedo considerably. The poor calibration of AVHRR channels 1 and 2 is another large impediment to making accurate albedo estimates.

Lindsay, R. W.↗

Response Versus Scan-Angle Corrections for MODIS Reflective Solar Bands Using Deep Convective Clouds

The absolute radiometric calibration of the reflective solar bands (RSBs) of Aqua- and Terra-MODIS is performed using on-board calibrators. A solar diffuser (SD) panel along with a solar diffuser stability monitor (SDSM) system, which tracks the performance of the SD over time, provides the absolute reference for calibrating the MODIS sensors. MODIS also views the moon and deep space through its space view (SV) port for lunar-based calibration and computing the zero input radiance, respectively. The MODIS instrument views the Earths surface through a two-sided scan mirror, whose reflectance is a function of angle of incidence (AOI) and is described by response versus scan-angle (RVS). The RVS for both MODIS instruments was characterized prior to launch. MODIS also views the SD and the moon at two different assigned RVS positions. There is sufficient evidence that the RVS is changing on orbit over time and as a function of wavelength. The SD and lunar observation scans can only track the RVS variation at two RVS positions. Consequently, the MODIS Characterization Support Team (MCST) developed enhanced approaches that supplement the onboard calibrator measurements with responses from pseudo-invariant desert sites. This approach has been implemented in Level 1B (L1B) Collection 6 (C6) for selected short-wavelength bands. This paper presents an alternative approach of characterizing the mirror RVS to derive the time-dependent RVS correction factors for MODIS RSBs using tropical deep convective cloud (DCC) targets. An initial assessment of the DCC response from Aqua-MODIS band 1 C6 data indicates evidence of RVS artifacts, which are not uniform across the scans and are more prevalent in the left side Earth-view scans.

Bhatt, Rajendra↗

Response Versus Scan-Angle Corrections for MODIS Reflective Solar Bands Using Deep Convective Clouds

The absolute radiometric calibration of the reflective solar bands (RSBs) of Aqua- and Terra-MODIS is performed using on-board calibrators. A solar diffuser (SD) panel along with a solar diffuser stability monitor (SDSM) system, which tracks the performance of the SD over time, provides the absolute reference for calibrating the MODIS sensors. MODIS also views the moon and deep space through its space view (SV) port for lunar-based calibration and computing the zero input radiance, respectively. The MODIS instrument views the Earth's surface through a two-sided scan mirror, whose reflectance is a function of angle of incidence (AOI) and is described by response versus scan-angle (RVS). The RVS for both MODIS instruments was characterized prior to launch. MODIS also views the SD and the moon at two different assigned RVS positions. There is sufficient evidence that the RVS is changing on orbit over time and as a function of wavelength. The SD and lunar observation scans can only track the RVS variation at two RVS positions. Consequently, the MODIS Characterization Support Team (MCST) developed enhanced approaches that supplement the onboard calibrator measurements with responses from pseudo-invariant desert sites. This approach has been implemented in Level 1B (L1B) Collection 6 (C6) for selected short-wavelength bands. This paper presents an alternative approach of characterizing the mirror RVS to derive the time-dependent RVS correction factors for MODIS RSBs using tropical deep convective cloud (DCC) targets. An initial assessment of the DCC response from Aqua-MODIS band 1 C6 data indicates evidence of RVS artifacts, which are not uniform across the scans and are more prevalent in the left side Earth-view scans.

Bhatt, Rajendra↗

Radiometric Calibration of the Earth Observing System's Imaging Sensors

The work on the grant was mainly directed towards developing new, accurate, redundant methods for the in-flight, absolute radiometric calibration of satellite multispectral imaging systems and refining the accuracy of methods already in use. Initially the work was in preparation for the calibration of MODIS and HIRIS (before the development of that sensor was canceled), with the realization it would be applicable to most imaging multi- or hyper-spectral sensors provided their spatial or spectral resolutions were not too coarse. The work on the grant involved three different ground-based, in-flight calibration methods reflectance-based radiance-based and diffuse-to-global irradiance ratio used with the reflectance-based method. This continuing research had the dual advantage of: (1) developing several independent methods to create the redundancy that is essential for the identification and hopefully the elimination of systematic errors; and (2) refining the measurement techniques and algorithms that can be used not only for improving calibration accuracy but also for the reverse process of retrieving ground reflectances from calibrated remote-sensing data. The grant also provided the support necessary for us to embark on other projects such as the ratioing radiometer approach to on-board calibration (this has been further developed by SBRS as the 'solar diffuser stability monitor' and is incorporated into the most important on-board calibration system for MODIS)- another example of the work, which was a spin-off from the grant funding, was a study of solar diffuser materials. Journal citations, titles and abstracts of publications authored by faculty, staff, and students are also attached.

Slater, Philip N.↗

Calibration and Data Analysis of a Frequency Selectable Laser Source for CMB Detector Characterization

Cosmic Microwave Background (CMB) experiments study faint radiation left over from the early universe. The CMB was created when the universe became cool enough for light to travel freely through space, and today it gives scientists one of the earliest images of the universe. One important goal of modern CMB experiments is to measure this radiation with higher precision in order to search for evidence that supports the theory of cosmic inflation. To do this, scientists use extremely sensitive detectors that must be calibrated accurately. The Frequency Selectable Laser Source, or FLS, is a new calibration tool that can send selected frequencies to detectors and help measure their response. During my internship, I worked on the FLS after it returned to Fermilab from Chile, where it had been used to characterize detectors at the Simons Observatory. The system came back in parts, so the first part of my project was helping rebuild the optical and mechanical setup. After the system was rebuilt, we performed alignments to maximize the receiver photocurrent. We then collected calibration measurements over different frequency ranges, including 543 GHz to 568 GHz, 740 GHz to 766 GHz, and 60 GHz to 500 GHz. These measurements were used to check waterline calibration and reflectivity features and compare new data with previous data. Another major part of my project was learning Python so I could understand previous analysis code, modify it for new files, and write my own code to compare the mean response between datasets. The results showed that the new data was close to previous measurements and that waterline features near 556 GHz and 752 GHz were found within less than 1.5 GHz of the expected values. I also completed the reflectivity analysis for five prisms in two polarization orientations. In the original orientation, the results were consistent between the five prisms and close to values measured on a different system at the University of Chicago. I then collected a second set of measurements on my own with the polarization of the laser rotated by 90 degrees and compared them with the original data using the same Python workflow. The measured reflectivity increased for all five prisms in the new orientation, showing that the prism reflectivity depends on polarization. Future work will focus on using the FLS to characterize real CMB detectors.

Pumarino, Rafael [Unlisted]↗

Calibration procedures for measurement of reflectance factor in remote sensing field research

A means by which measurements of the optical properties of crops and soils can be knowledgeably compared from site to site and instrument to instrument is presented in detail. The definition of bidirectional reflectance factor is reviewed and discussed. Procedures for field implementation are illustrated and discussed. Spectral and goniometric properties of laboratory and field reference surfaces and typical environmental subjects serve as a basis for analysis of uncertainties introduced by differing illumination conditions. Results of a comparison of the performance of three spectrometer systems are presented and discussed. It is concluded that intelligent use of the bidirectional reflectance factor technique is an accurate and practical means to obtain the spectral, optical properties of crops and soils needed for advancements in agricultural remote sensing.

Robinson, B. F.↗

Microwave limb sounder

Trace gases in the upper atmosphere can be measured by comparing spectral noise content of limb soundings with the spectral noise content of cold space. An offset Cassegrain antenna system and tiltable input mirror alternately look out at the limb and up at cold space at an elevation angle of about 22. The mirror can also be tilted to look at a black body calibration target. Reflection from the mirror is directed into a radiometer whose head functions as a diplexer to combine the input radiation and a local ocillator (klystron) beam. The radiometer head is comprised of a Fabry-Perot resonator consisting of two Fabry-Perot cavities spaced a number of half wavelengths apart. Incoming radiation received on one side is reflected and rotated 90 deg in polarization by the resonator so that it will be reflected by an input grid into a mixer, while the klystron beam received on the other side is also reflected and rotated 90 deg, but not without passing some energy to be reflected by the input grid into the mixer.

Gustincic, J. J.↗

Calibration procedures for measurement of reflectance factor in remote sensing field research

A means by which measurements of the optical properties of crops and soils can be knowledgeably compared from site to site and instrument to instrument is presented in detail. The definition of bidirectional reflectance factor is reviewed and discussed. Procedures for field implementation are illustrated and discussed. Spectral and goniometric properties of laboratory and field reference surfaces are given. It is concluded that intelligent use of the bidirectional reflectance factor technique is an accurate and practical means to obtain the spectral, optical properties of crops and soils needed for advancements in agricultural remote sensing.

Robinson, B. F.↗

Clouds as calibration targets for AVHRR reflected-solar channels - Results from a two-year study at NOAA/NESDIS

NOAA-11 Advanced Very High Resolution Radiometer (AVHRR) and associated ground-based data have been collected at NOAA/NESDIS, on a daily basis and for 600 days, using five stations within the continental United States in the NOAA solar radiation (SOLRAD) monitoring network. The data have been filtered to include only uniformly overcast conditions and analyzed along the lines described by Paris and Justus (1988). Results from this first long-term pilot operational application of the method are presented. The method is potentially useful for establishing yearly-averaged trends in the radiometric gain of AVHRR Channels. The relatively small data base examined here suggests a precision in the 600 day mean gain of 5 percent or worse, with a significant part of this uncertainty being driven by poor knowlege of the bidirectional reflectance properties of clouds. The results suggest that the method in its present formulation has insufficient precision to be used as a primary method for the measurement of in-orbit gains of reflected-solar radiometers aboard polar orbiting satellites. Intrinsic limitations to the precision and time resolution of the method are discussed, and suggestions are offered for improving the precision of future results.

Abel, Peter↗

Compositional diversity of the lunar North Pole: Preliminary analyses of Galileo SSI data

In December 1992, the Galileo spacecraft passed through the Earth-Moon system for its final gravity assist to Jupiter. The SSI camera obtained several 6-color mosaics of the lunar north polar region and the sunlit nearside and eastern limb at approximately 1.3 km/pixel. Initial analyses have concentrated on the north polar areas to assess the composition of the crust in that region. Representative 6-color calibration SSI spectra (typically 5 x 5 pixels) are shown. Photometric corrections have not yet been applied, and all spectra are scaled to unity at 0.56 microns. The data were first calibrated relative to MS2, a standard are in Mare Serenitatis (18.7 deg N, 21.5 deg E), and the top four plots of highlands, highland craters, maria, and mare craters are displayed relative to MS2. SSI spectra of areas measured with telescopic data (mare MT1/MS2 and mare crater MSA/MS2) agree well with previous data, confirming that the calibration procedures and SSI data are spectrally accurate. The bottom three plots of craters/sun have been calibrated to reflectance using previously obtained telescopic spectra of Apollo 16/MS2 (shown with Highlands/MS2) and laboratory spectra of mature Apollo 16 soil (shown for reference with the Highland Craters/Sun). Although some variations in these spectra mimic previously observed spectra of lunar terrains, several characteristics are unusual. Familiar and unfamiliar properties are observed in these northern latitudes and both types merit further investigation in their geologic context.

Pieters, C. M.↗

Columnar Aerosol Single-Scattering Albedo and Phase Function Retrieved from Sky Radiance Over the Ocean: Measurements of African Dust

The single-scattering albedo and phase function of African mineral dust are retrieved from ground-based measurements of sky radiance collected in the Florida Keys. The retrieval algorithm employs the radiative transfer equation to solve by iteration for these two properties which best reproduce the observed sky radiance using an assumed aerosol vertical structure and measured aerosol optical depth. Thus, no assumptions regarding particle size, shape, or composition are required. The single-scattering albedo, presented at fourteen wavelengths between 380 and 870 nm, displays a spectral shape expected of iron-bearing minerals but is much higher than current dust models allow. This indicates the absorption of light by mineral dust is significantly overestimated in climate studies. Uncertainty in the retrieved albedo is less than 0.02 due to the small uncertainty in the solar-reflectance-based calibration (12.2%) method employed. The phase function retrieved at 860 nm is very robust under simulations of expected experimental errors, indicating retrieved phase functions at this wavelength may be confidently used to describe aerosol scattering characteristics. The phase function retrieved at 443 nm is very sensitive to expected experimental errors and should not be used to describe aerosol scattering. Radiative forcing by aerosol is the greatest source of uncertainty in current climate models. These results will help reduce uncertainty in the absorption of light by mineral dust. Assessment of the radiative impact of aerosol species is a key component to NASA's Earth System Enterprise.

Cattrall, Christopher↗