Search NASA⌕ Search

SEARCH · Search NASA

Results for “study protocol”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 163 records · Page 9

Reference dosimetry for helical tomotherapy: Practical implementation and a multicenter validation

Purpose: The aim of this study was to implement a protocol for reference dosimetry in tomotherapy and to validate the beam output measurements with an independent dosimetry system. Methods: Beam output was measured at the reference depth of 10 cm in water for the following three cases: (1) a 5 x 10 cm{sup 2} static machine specific reference field (MSR), (2) a rotational 5 x 10 cm{sup 2} field without modulation and no tabletop in the beam, (3) a plan class specific reference (PCSR) field defined as a rotational homogeneous dose delivery to a cylindrical shaped target volume: plan with modulation and table-top movement. The formalism for reference dosimetry of small and nonstandard fields [Med.Phys.35: 5179-5186, 2008] and QA recommendations [Med.Phys.37: 4817-4853, 2010] were adopted in the dose measurement protocol. All ionization chamber measurements were verified independently using alanine/EPR dosimetry. As a pilot study, the beam output was measured on tomotherapy Hi-art systems at three other centers and directly compared to the centers specifications and to alanine dosimetry. Results: For the four centers, the mean static output at a depth of 10 cm in water and SAD = 85 cm, measured with an A1SL chamber following the TG-148 report was 6.238 Gy/min {+-} 0.058 (1 SD); the rotational output was 6.255 Gy/min {+-} 0.069 (1 SD). The dose stated by the center was found in good agreement with the measurements of the visiting team: D{sub center}/D{sub visit} = 1.000 {+-} 0.003 (1 SD). The A1SL chamber measurements were all in good agreement with Alanine/EPR dosimetry. Going from the static reference field to the rotational/non modulated field the dose rate remains constant within 0.2% except for one center where a deviation of 1.3% was detected. Conclusions: Following the TG-148 report, beam output measurements in water at the reference depth using a local protocol, as developed at different centers, was verified. The measurements were found in good agreement with alanine/EPR dosimetry. The presented methodology may provide a good concept for reference dosimetry.

61 RADIATION PROTECTION AND DOSIMETRY↗

Multi-Scale Microfluidics for Transport in Shale Fabric

We develop a microfluidic experimental platform to study solute transport in multi-scale fracture networks with a disparity of spatial scales ranging between two and five orders of magnitude. Using the experimental scaling relationship observed in Marcellus shales between fracture aperture and frequency, the microfluidic design of the fracture network spans all length scales from the micron (1 μ) to the dm (10 dm). This intentional `tyranny of scales’ in the design, a determining feature of shale fabric, introduces unique complexities during microchip fabrication, microfluidic flow-through experiments, imaging, data acquisition and interpretation. Here, we establish best practices to achieve a reliable experimental protocol, critical for reproducible studies involving multi-scale physical micromodels spanning from the Darcy- to the pore-scale (dm to μm). With this protocol, two fracture networks are created: a macrofracture network with fracture apertures between 5 and 500 μm and a microfracture network with fracture apertures between 1 and 500 μm. The latter includes the addition of 1 μm ‘microfractures’, at a bearing of 55°, to the backbone of the former. Comparative analysis of the breakthrough curves measured at corresponding locations along primary, secondary and tertiary fractures in both models allows one to assess the scale and the conditions at which microfractures may impact passive transport.

58 GEOSCIENCES↗

SU-E-I-33: Establishment of CT Diagnostic Reference Levels in Province Nova Scotia

Purpose: To evaluate patient radiation dose from the most frequently performed CT examinations and to establish provincial diagnostic reference levels (DRLs) as a tool for protocol optimization. Methods: The study investigated the following CT examinations: head, chest, abdomen/pelvis, and chest/abdomen/pelvis (CAP). Dose data, volume CT dose index (CTDIvol) and dose-length product (DLP), were collected from 15 CT scanners installed during 2004–2014 in 11 hospital sites of Nova Scotia. All scanners had dose modulation options and multislice capability (16–128 detector rows). The sample for each protocol included 15 average size patients (70±20 kg). Provincial DRLs were calculated as the 75th percentile of patient dose distributions. The differences in dose between hospitals were evaluated with a single factor ANOVA statistical test. Generalized linear modeling was used to determine the factors associated with higher radiation dose. A sample of 36 abdominal studies performed on three different scanners was blinded and randomized for an assessment by an experienced radiologist who graded the imaging quality of anatomic structures. Results: Data for 900 patients were collected. The DRLs were proposed using CTDIvol (mGy) and DLP (mGy*cm) values for CT head (67 and 1049, respectively), chest (12 and 393), abdomen/pelvis (16 and 717), and CAP (14 and 1034). These DRLs were lower than the published national data except for the head CTDIvol. The differences between the means of the dose distributions from each scanner were statistically significant (p<0.05) for all examinations. A very weak correlation was found between the dose and the scanner age or the number of slices with Pearson’s correlation coefficients of 0.011–0.315. The blinded analysis of image quality demonstrated no clinically significant difference except for the noise category. Conclusion: Provincial DRLs were established for typical CT examinations. The variations in dose between the hospitals suggested a large potential for optimization of examinations. Radiology Research Foundation grant.

60 APPLIED LIFE SCIENCES↗

Strategies for Probing Nanometer-Scale Electrocatalysts: From Single Particles to Catalyst-Membrane Architectures

The project primary objectives are to prepare and elucidate the promoting properties of materials that possess high activity for the conversion of hydrogen and related small molecules (water, oxygen, carbon monoxide and methanol) in polymer electrolyte fuel cells. One area of research has focused on the study of catalyst materials. Protocols were developed for probing the structure and benchmarking the activity of Pt and Pt bimetallic nanometer-scale catalyst against Pt single crystal electrode standards. A second area has targeted fuel cell membrane and the advancement of simple methods mainly based on vibrational spectroscopy that can be applied broadly in the study of membrane structure and transport properties. Infrared and Raman methods combined with least-squares data modeling were applied to investigate and assist the design of robust, proton conductive membranes, which resist reactant crossover.

08 HYDROGEN↗

Remote state preparation of spatial qubits

We study the quantum communication protocol of remote state preparation (RSP) for pure states of qubits encoded in single photons transmitted through a double slit, the so-called spatial qubits. Two measurement strategies that one can adopt to remotely prepare the states are discussed. The first strategy is the well-known spatial postselection, where a single-pixel detector measures the transverse position of the photon between the focal and the image plane of a lens. The second strategy, proposed by ourselves, is a generalized measurement divided into two steps: the implementation of a two-outcome positive operator-valued measurement (POVM) followed by the spatial postselection at the focal plane of the lens by a two-pixel detector in each output of the POVM. In both cases we analyze the effects of the finite spatial resolution of the detectors over three figures of merit of the protocol, namely, the probability of preparation, the fidelity, and purity of the remotely prepared states. It is shown that our strategy improves these figures compared with spatial postselection, at the expense of increasing the classical communication cost as well as the required experimental resources. In addition, we present a modified version of our strategy for RSP of spatial qudits which is able to prepare arbitrary pure states, unlike spatial postselection alone. We expect that our study may also be extended for RSP of the angular spectrum of a single-photon field as an alternative for quantum teleportation which requires very inefficient nonlinear interactions.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Efficiency Improvement in a Busy Radiology Practice: Determination of Musculoskeletal Magnetic Resonance Imaging Protocol Using Deep-Learning Convolutional Neural Networks

The purposes of this study are to evaluate the feasibility of protocol determination with a convolutional neural networks (CNN) classifier based on short-text classification and to evaluate the agreements by comparing protocols determined by CNN with those determined by musculoskeletal radiologists. Following institutional review board approval, the database of a hospital information system (HIS) was queried for lists of MRI examinations, referring department, patient age, and patient gender. These were exported to a local workstation for analyses: 5258 and 1018 consecutive musculoskeletal MRI examinations were used for the training and test datasets, respectively. The subjects for pre-processing were routine or tumor protocols and the contents were word combinations of the referring department, region, contrast media (or not), gender, and age. The CNN Embedded vector classifier was used with Word2Vec Google news vectors. The test set was tested with each classification model and results were output as routine or tumor protocols. The CNN determinations were evaluated using the receiver operating characteristic (ROC) curves. The accuracies were evaluated by a radiologist-confirmed protocol as the reference protocols. The optimal cut-off values for protocol determination between routine protocols and tumor protocols was 0.5067 with a sensitivity of 92.10%, a specificity of 95.76%, and an area under curve (AUC) of 0.977. The overall accuracy was 94.2% for the ConvNet model. All MRI protocols were correct in the pelvic bone, upper arm, wrist, and lower leg MRIs. Deep-learning-based convolutional neural networks were clinically utilized to determine musculoskeletal MRI protocols. CNN-based text learning and applications could be extended to other radiologic tasks besides image interpretations, improving the work performance of the radiologist.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Correlative X-ray micro-nanotomography with scanning electron microscopy at the Advanced Light Source

Geological samples are inherently multi-scale. Understanding their bulk physical and chemical properties requires characterization down to the nano-scale. A powerful technique to study the three-dimensional microstructure is X-ray tomography, but it lacks information about the chemistry of samples. To develop a methodology for measuring the multi-scale 3D microstructure of geological samples, correlative X-ray micro- and nanotomography were performed on two rocks followed by scanning electron microscopy with energy-dispersive spectroscopy (SEM-EDS) analysis. The study was performed in five steps: (i) micro X-ray tomography was performed on rock sample cores, (ii) samples for nanotomography were prepared using laser milling, (iii) nanotomography was performed on the milled sub-samples, (iv) samples were mounted and polished for SEM analysis and (v) SEM imaging and compositional mapping was performed on micro and nanotomography samples for complimentary information. Correlative study performed on samples of serpentine and basalt revealed multiscale 3D structures involving both solid mineral phases and pore networks. Significant differences in the volume fraction of pores and mineral phases were also observed dependent on the imaging spatial resolution employed. This highlights the necessity for the application of such a multiscale approach for the characterization of complex aggregates such as rocks. Information acquired from the chemical mapping of different phases was also helpful in segmentation of phases that did not exhibit significant contrast in X-ray imaging. Adoption of the protocol used in this study can be broadly applied to 3D imaging studies being performed at the Advanced Light Source and other user facilities.

58 GEOSCIENCES↗

Comorbid conditions in individuals assessed by SPECT: Study of a reference cardiology center in Mexico City

Background: There is an increasing prevalence of comorbidities in patients with ischemic heart disease (IHD) in developing countries. The aim of this work is to assess the prevalence of comorbidities and associated factors for IHD among patients at a reference cardiology center. Design and Methods: This was a cross-sectional study. A complete clinical history which focused on the main comorbidities, previous myocardial infarction, and the main reason of referral was assessed. A single-photon emission computed tomography (SPECT) myocardial perfusion study (MPS) with two protocols was performed. Results: We included 1998 patients, 64.2% male, median age 63 (I.R.: 56–71) years. 1514 (75.8%) subjects had at least one associated comorbidity. The main comorbidity was diabetes (T2D) (772: 38.6%), followed by systemic hypertension (737: 36.9%), smoking (518: 25.9%), and dyslipidemia (517: 25.9%). 806 (40.3%) had histories of previous myocardial infarctions. The main cause of referral was angina (923: 46.2%). We identified 1330 (66.5%) abnormal MPS. 460 (23%) had ischemia, 292 (14.6%) infarction, and 578 (28.9%) ischemia and infarction. Conclusion: An increased prevalence of comorbidities was found in patients who were studied in the Nuclear Cardiology Department (NCD): most of them had traditional risk factors attributable to myocardial infarction. A great percentage were newly diagnosed with both ischemia and infarction.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Optimization of Feasibility Stage for Hydrogen/Deuterium Exchange Mass Spectrometry

The practice of HDX-MS remains somewhat difficult, not only for newcomers but also for veterans, despite its increasing popularity. While a typical HDX-MS project starts with a feasibility stage where the experimental conditions are optimized and the peptide map is generated prior to the HDX study stage, the literature usually reports only the HDX study stage. In this protocol, we describe a few considerations for the initial feasibility stage, more specifically, how to optimize quench conditions, how to tackle the carryover issue, and how to apply the pepsin specificity rule. Two sets of quench conditions are described depending on the presence of disulfide bonds to facilitate the quench condition optimization process. Four protocols are outlined to minimize carryover during the feasibility stage: (1) addition of a detergent to the quench buffer, (2) injection of a detergent or chaotrope to the protease column after each sample injection, (3) back-flushing of the trap column and the analytical column with a new plumbing configuration, and (4) use of PEEK (or PEEK coated) frits instead of stainless steel frits for the columns. The application of the pepsin specificity rule after peptide map generation and not before peptide map generation is suggested. The rule can be used not only to remove falsely identified peptides, but also to check the sample purity. A well-optimized HDX-MS feasibility stage makes subsequent HDX study stage smoother and the resulting HDX data more reliable. .

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

A Comparative Study of Sample Preparation for Staining and Immunodetection of Plant Cell Walls by Light Microscopy

Staining and immunodetection by light microscopy are methods widely used to investigate plant cell walls. The two techniques have been crucial to study the cell wall architecture in planta , its deconstruction by chemicals or cell wall-degrading enzymes. They have been instrumental in detecting the presence of cell types, in deciphering plant cell wall evolution and in characterizing plant mutants and transformants. The success of immunolabeling relies on how plant materials are embedded and sectioned. Agarose coating, wax and resin embedding are, respectively, associated with vibratome, microtome and ultramicrotome sectioning. Here, we have systematically carried out a comparative analysis of these three methods of sample preparation when they are applied for cell wall staining and cell wall immunomicroscopy. In order to help the plant community in understanding and selecting adequate methods of embedding and sectioning for cell wall immunodetection, we review in this article the advantages and limitations of these three methods. Moreover, we offer detailed protocols of embedding for studying plant materials through microscopy.

59 BASIC BIOLOGICAL SCIENCES↗

Entangling quantum logic gates in neutral atoms via the microwave-driven spin-flip blockade

The Rydberg dipole blockade has emerged as the standard mechanism to induce entanglement between neutral-atom qubits. In these protocols, laser fields that couple qubit states to Rydberg states are modulated to implement entangling gates. Here, in this study, we present an alternative protocol to implement entangling gates via Rydberg dressing and a microwave-field-driven spin-flip blockade. We consider the specific example of qubits encoded in the clock states of cesium. An auxiliary hyperfine state is optically dressed so that it acquires partial Rydberg character. It thus acts as a proxy Rydberg state, with a nonlinear light shift that plays the role of blockade strength. A microwave-frequency field coupling a qubit state to this dressed auxiliary state can be modulated to implement entangling gates. Logic gate protocols designed for the optical regime can be imported to this microwave regime, for which experimental control methods are more robust. We show that unlike the strong dipole-blockade regime usually employed in Rydberg experiments, going to a moderate-spin-flip-blockade regime results in faster gates and smaller Rydberg decay. We study various regimes of operations that can yield high-fidelity two-qubit entangling gates and characterize their analytical behavior. In addition to the inherent robustness of microwave control, we can design these gates to be more robust to laser amplitude and frequency noises at the cost of a small increase in Rydberg decay.

74 ATOMIC AND MOLECULAR PHYSICS↗

Lead and Arsenic Bioaccessibility and Speciation as a Function of Soil Particle Size

Bioavailability research of soil metals has advanced considerably from default values to validated in vitro bioaccessibility (IVBA) assays for site‐specific risk assessment. Previously, USEPA determined that the soil‐size fraction representative of dermal adherence and consequent soil ingestion was <250 μm. This size fraction was widely used in testing efforts for both in vivo and in vitro experiments. However, recent studies indicate the <150‐μm size fraction better represents the particle size that adheres to skin for potential ingestion. At issue is the relevance of validated in vivo and in vitro methods developed with <250 μm moving to the <150‐μm fraction. The objectives of this study were to investigate <250‐μm versus <150‐μm particle size and particle size groups for evaluating lead (Pb) and arsenic (As) IVBA and speciation. Soils with different properties were homogenized, oven dried, and sieved: <250 to > 150, <150 to >75, <75 to >38, and <38 μm. Sieved versus ground subsamples of <250‐μm and <150‐μm bulk soils were also used for IVBA and synchrotron‐based Pb and As speciation. Although we observed an increase in total and IVBA‐extractable Pb and As with decreased soil particle size, changes in %IVBA of Pb and As (dependent on the ratio extractable:total) remained consistent in all of the tested soils. No significant changes in Pb and As speciation were observed across the soil fractions. The results suggest that using the more relevant <150‐μm fraction will not undermine currently validated IVBA protocols in future bioavailability studies. Core Ideas Identified critical knowledge gaps regarding the <250‐μm vs. <150‐μm particle size used for IVBA. Wider implementation of the <150‐μm size fraction maintains past validation with <‐250 μm fraction. Regardless of increase in total and extractable Pb and As, %IVBA results remained consistent. Using <150‐μm particle size for IVBA requires much higher volumes/masses of soils. Synchrotron‐based speciation is significant in bioavailability studies to understand the fate and transport of contaminants.

Karna, Ranju R.↗

SU-C-18C-04: Evaluation of Effective Dose During Ureteroscopy for Obese and Non-Obese Patients

Purpose: Ureteroscopy involves fluoroscopy which potentially results in considerable amount of radiation dose to the patient. Purpose of this study was two-fold: (a) to develop the effective dose computational model for obese and non-obese patients undergoing left and right ureteroscopy, and (b) to evaluate the utility of a commercial Monte Carlo software for dose assessment in ureteroscopy. Methods: Organ dose measurements were performed on an adult male anthropomorphic phantom, representing the non-obese patients, with 20 high-sensitivity MOSFET detectors and two 0.18cc ionization chambers placed in selected organs. Fat-equivalent paddings were placed around the abdominal region to simulate for obese patients. Effective dose (ED) was calculated using ICRP 103 tissue weighting factors and normalized to the effective dose rate in miliSivert per second (mSv/s). In addition, a commercial Monte Carlo (MC) dose estimation program was used to estimate ED for the non-obese model, with table attenuation correction applied to simulate clinical procedure. Results: For the equipment and protocols involved in this study, the MOSFETderived ED rates for the obese patient model (‘Left’: 0.0092±0.0004 mSv/s; ‘Right’: 0.0086±0.0004 mSv/s) was found to be more than twice as much as that to the non-obese patient model (‘Left’: 0.0041±0.0003 mSv/s; ‘Right’: 0.0036±0.0007 mSv/s). The MC-derived ED rates for the non-obese patient model (‘Left’: 0.0041 mSv/s; ‘Right’: 0.0036 mSv/s; with statistical uncertainty of 1%) showed a good agreement with the MOSFET method. Conclusion: The significant difference in ED rate between the obese and non-obese patient models shows the limitation of directly applying commercial softwares for obese patients and leading to considerable underestimation of ED. Although commercial softwares offer a convenient means of dose estimation, but the utility may be limited to standard-man geometry as the software does not account for table attenuation, obese patient geometry, and differences between the anthropomorphic phantom and MC mathematical phantom.

60 APPLIED LIFE SCIENCES↗

Using remote sensing to quantify the additional climate benefits of California forest carbon offset projects

Abstract Nature‐based climate solutions are a vital component of many climate mitigation strategies, including California's, which aims to achieve carbon neutrality by 2045. Most carbon offsets in California's cap‐and‐trade program come from improved forest management (IFM) projects. Since 2012, various landowners have set up IFM projects following the California Air Resources Board's IFM protocol. As many of these projects approach their 10th year, we now have the opportunity to assess their effectiveness, identify best practices, and suggest improvements toward future protocol revisions. In this study, we used remote sensing‐based datasets to evaluate the carbon trends and harvest histories of 37 IFM projects in California. Despite some current limitations and biases, these datasets can be used to quantify carbon accumulation and harvest rates in offset project lands relative to nearby similar “control” lands before and after the projects began. Five lines of evidence suggest that the carbon accumulated in offset projects to date has generally not been additional to what might have otherwise occurred: (1) most forests in northwestern California have been accumulating carbon since at least the mid‐1980s and continue to accumulate carbon, whether enrolled in offset projects or not; (2) harvest rates were high in large timber company project lands before IFM initiation, suggesting they are earning carbon credits for forests in recovery; (3) projects are often located on lands with higher densities of low‐timber‐value species; (4) carbon accumulation rates have not yet increased on lands that enroll as offset projects, relative to their pre‐enrollment levels; and (5) harvest rates have not decreased on most project lands since offset project initiation. These patterns suggest that the current protocol should be improved to robustly measure and reward additionality. In general, our framework of geospatial analyses offers an important and independent means to evaluate the effectiveness of the carbon offsets program, especially as these data products continue improving and as offsets receive attention as a climate mitigation strategy.

59 BASIC BIOLOGICAL SCIENCES↗

Single-Centre Experience with Percutaneous Cryoablation of Breast Cancer in 23 Consecutive Non-surgical Patients

AimTo present our single-centre prospective experience on the use of cryoablation (CA) applied to treat primary breast cancer (BC) in a cohort of patients unsuitable for surgical treatment.Materials and MethodsTwenty-three consecutive post-menopausal female patients (median age 85 years; range 56–96) underwent percutaneous CA of unifocal, biopsy-proven BC, under ultrasound/computed tomography (US/CT) guidance. Clinical and dynamic contrast-enhanced magnetic resonance imaging (DCE-MRI) follow-ups were systematically scheduled at 3, 12, 18 and 24 months. Local tumour control was assessed by comparing baseline and follow-up DCE-MRI.ResultsTwenty-three BC (median size 14 mm) were treated under local anaesthesia (78.3 %) or local anaesthesia and conscious sedation (21.7 %). Median number of cryo-probes applied per session was 2.0. A “dual-freezing” protocol was applied for the first ten patients and a more aggressive “triple-freezing” protocol for the remaining 13. Median follow-up was 14.6 months. Five patients recurred during follow-up and two were successfully re-treated with CA. Five patients presented immediate CA-related complications: four hematomas evolved uneventfully at 3-month follow-up and one skin burn resulted in skin inflammation and skin retraction at 3 and 12 months, respectively.ConclusionsPercutaneous CA is safe and well tolerated for non-resected elderly BC patients. Procedures can be proposed under local anaesthesia only. Given the insulation properties of the breast gland, aggressive CA protocols are required. Prospective studies are needed to better understand the potential role of CA in the local treatment of early BC.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Metals and methylotrophy: Via global gene expression studies

A number of minerals, such as copper, cobalt, and rare earth elements (REE), are essential modulators of microbial one-carbon metabolism. This chapter provides an overview of the gene expression study design and analysis protocols for uncovering REE-induced changes in methylotrophic bacteria. By interrogating relationships and differences in total gene expression induced by mineral micronutrients, a deeper understanding of gene regulation at a systems scale can be gained. With careful design and execution of RNA-sequencing experiments, thorough processing and assessment of read quality can be utilized to assess and adjust for possible biases. Here, by ensuring only quality data are utilized in downstream processes, differential gene expression, overrepresented analyses, and gene-set enrichment analyses provide reliable and reproducible representation of pathways and functions which are being affected by changes in environmental conditions.

59 BASIC BIOLOGICAL SCIENCES↗

Weak measurement and Bohmian conditional wave functions

It was recently pointed out and demonstrated experimentally by Lundeen et al. that the wave function of a particle (more precisely, the wave function possessed by each member of an ensemble of identically-prepared particles) can be “directly measured” using weak measurement. Here it is shown that if this same technique is applied, with appropriate post-selection, to one particle from a perhaps entangled multi-particle system, the result is precisely the so-called “conditional wave function” of Bohmian mechanics. Thus, a plausibly operationalist method for defining the wave function of a quantum mechanical sub-system corresponds to the natural definition of a sub-system wave function which Bohmian mechanics uniquely makes possible. Similarly, a weak-measurement-based procedure for directly measuring a sub-system’s density matrix should yield, under appropriate circumstances, the Bohmian “conditional density matrix” as opposed to the standard reduced density matrix. Experimental arrangements to demonstrate this behavior–and also thereby reveal the non-local dependence of sub-system state functions on distant interventions–are suggested and discussed. - Highlights: • We study a “direct measurement” protocol for wave functions and density matrices. • Weakly measured states of entangled particles correspond to Bohmian conditional states. • Novel method of observing quantum non-locality is proposed.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Biodistribution of the boron carriers boronophenylalanine (BPA) and/or decahydrodecaborate (GB-10) for Boron Neutron Capture Therapy (BNCT) in an experimental model of lung metastases

BNCT was proposed for the treatment of diffuse, non-resectable tumors in the lung. We performed boron biodistribution studies with 5 administration protocols employing the boron carriers BPA and/or GB-10 in an experimental model of disseminated lung metastases in rats. All 5 protocols were non-toxic and showed preferential tumor boron uptake versus lung. Absolute tumor boron concentration values were therapeutically useful (25–76 ppm) for 3 protocols. Dosimetric calculations indicate that BNCT at RA-3 would be potentially therapeutic without exceeding radiotolerance in the lung.

99 GENERAL AND MISCELLANEOUS↗