Search NASA⌕ Search

SEARCH · Search NASA

Results for “superconducting transition edge sensor”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 163 records · Page 9

Advanced ACTPol Cryogenic Detector Arrays and Readout

Advanced ACTPol is a polarization-sensitive upgrade for the 6 m aperture Atacama Cosmology Telescope, adding new frequencies and increasing sensitivity over the previous ACTPol receiver. In 2016, Advanced ACTPol will begin to map approximately half the sky in five frequency bands (28-230 GHz). Its maps of primary and secondary cosmic microwave background anisotropies-imaged in intensity and polarization at few arcminute-scale resolution-will enable precision cosmological constraints and also awide array of cross-correlation science that probes the expansion history of the universe and the growth of structure via gravitational collapse. To accomplish these scientific goals, the AdvancedACTPol receiver will be a significant upgrade to the ACTPol receiver, including four new multichroic arrays of cryogenic, feedhorn-coupled AlMn transition edge sensor polarimeters (fabricated on 150 mm diameter wafers); a system of continuously rotating meta-material silicon half-wave plates; and a new multiplexing readout architecture which uses superconducting quantum interference devices and time division to achieve a 64-row multiplexing factor. Here we present the status and scientific goals of the Advanced ACTPol instrument, emphasizing the design and implementation of the AdvancedACTPol cryogenic detector arrays.

secondary cosmic microwave background anisotropies↗

High Resolution Fission Fragment Spectroscopy with Superconducting Microcalorimeters

Sub-1 AMU mass determination is important for determining fission yields and neutron multiplicity, which are necessary inputs for fission models. Fission models can improve spent nuclear waste stream analysis and nuclear fuel burnup determination. Here, to achieve this goal, we have used superconducting microcalorimeter detectors to directly measure the energy of fission fragments from the spontaneous fission of 252 Cf. With a fiber coupled LED pulser setup we demonstrate that we can reach a relative energy resolution of 0.1% and better for photon pulses with energies above 60 MeV. This instrument, in conjunction with time-of-flight (TOF) measurement, would allow for sub-1 atomic mass unit (AMU) mass determination of fission fragments in a future beamline application.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

AlMn Transition Edge Sensors for Advanced ACTPol

Advanced ACTPol (Adv ACT) will use an array of multichroic polarization sensitive AIMn transition edge sensor (TES) bolometers read out through time-division multiplexing. Aluminum doped with a low concentration of manganese can be deposited to a bulk film thickness for a more reliable superconducting critical temperature uniformity compared to thin bilayers. To build the TES, the AlMn alloy is deposited, over Nb wiring, to a specific thickness to set the TES normal resistance. The doping concentration of manganese coarsely defines the TES critical temperature, while a fine tuning is achieved by heating the deposited film to a specific temperature. The TES island is connected to the thermal bath via four silicon-nitride membranes, where their geometry defines the thermal conductance to the temperature of the bath. Lastly, the TES heat capacity is increased by addition of PdAu electrically connected to the AlMn film. Designs and performance characteristics of these AlMn TESs are presented for use in AdvACT.

Advanced ACTPol (AdvACT)↗

Lynx x-ray microcalorimeter

Lynx is an x-ray telescope, one of four large satellite mission concepts currently being studied by NASA to be a flagship mission. One of Lynx’s three instruments is an imaging spectrometer called the Lynx x-ray microcalorimeter (LXM), an x-ray microcalorimeter behind an x-ray optic with an angular resolution of 0.5 arc sec and ∼2 sq. m of area at 1 keV. The LXM will provide unparalleled diagnostics of distant extended structures and, in particular, will allow the detailed study of the role of cosmic feedback in the evolution of the Universe. We discuss the baseline design of LXM and some parallel approaches for some of the key technologies. The baseline sensor technology uses transition-edge sensors, but we also consider an alternative approach using metallic magnetic calorimeters. We discuss the requirements for the instrument, the pixel layout, and the baseline readout design, which uses microwave superconducting quantum interference devices and high-electron mobility transistor amplifiers and the cryogenic cooling requirements and strategy for meeting these requirements. For each of these technologies, we discuss the current technology readiness level and our strategy for advancing them to be ready for flight. We also describe the current system design, including the block diagram, and our estimate for the mass, power, and data rate of the instrument.

Simon R. Bandler↗

A Path to High Efficiency Optical Coupling for HIRMES

The high-resolution mid-infrared spectrometer (HIRMES) under development for SOFIA (Stratospheric Observatory for Infrared Astronomy) is an instrument operating in the 25-122 μm spectral range with a spectral resolution R= Δ ʎ /ʎ ~100,000 and has two absorber-coupled transition edge sensor (TES) bolometric detector focal planes. We have developed novel NbTiN low stress absorber coatings which have the required optical impedance across the HIRMES operating band. The low intrinsic stress of these coatings allow for a peak-to-valley corrugation amplitude < 5 μm of the 450 nm thick, 1.4 mm x 1.7 mm detector pixels. Furthermore, these coatings have a superconducting transition temperature ~ 10 K, which allows them to simultaneously serve as an absorber in the desired signal band and a rejection filter at long wavelengths. This attribute makes them especially attractive for ultrasensitive absorber-coupled bolometric detector applications, because it helps in controlling the optical loading from out-of band radiation. We also discuss a novel method for integrating a wedged reflective absorber-termination to the detector array.

bolometers↗

Cosmic Microwave Background Polarization Detector with High Efficiency, Broad Bandwidth, and Highly Symmetric Coupling to Transition Edge Sensor Bolometers

Four probe antennas transfer signals from waveguide to microstrip lines. The probes not only provide broadband impedance matching, but also thermally isolate waveguide and detector. In addition, we developed a new photonic waveguide choke joint design, with four-fold symmetry, to suppress power leakage at the interface. We have developed facilities to test superconducting circuit elements using a cryogenic microwave probe station, and more complete systems in waveguide. We used the ring resonator shown below to measure a dielectric loss tangent < 7x10(exp -4) over 10 - 45 GHz. We have combined component simulations to predict the overall coupling from waveguide modes to bolometers. The result below shows the planar circuit and waveguide interface can utilize the high beam symmetry of HE11 circular feedhorns with > 99% coupling efficiency over 30% fractional bandwidth.

Wollack, E.↗

Hyperspectral X-ray Imaging: Progress Towards Chemical Analysis in the SEM

The Hyperspectral X-ray Imaging (HXI) project will enable non-destructive chemical-state determination of nano-scale samples in the electron microscope for nuclear safeguards applications. To efficiently measure chemical state through electron-excited X-ray emission requires a combination of wide spectral bandwidth, high resolution, and high count rate capability. We are building a next-generation X-ray detector based on an array of transition edge sensors (TESs) to make these measurements possible and routine in the scanning electron microscope (SEM). Leveraging the large pixel densities afforded by microwave multiplexing readout and continuous, uninterrupted operation of a cryogen-free dilution refrigerator, this instrument will have efficiency to allow chemical species identification of nano-scale samples in hours instead of days to weeks. We describe prototype pixel designs for this HXI instrument, comprising three pixel types that will make up the hybrid TES array. Engineering design of the integrated HXI cryostat and SEM system is in progress, with full detector commissioning expected in Spring 2021 followed closely by full-scale integration with the SEM. Furthermore, we also report on the commissioning of a complementary TES-based X-ray emission spectroscopy platform for bulk samples to build a spectral library for HXI sample identification.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Fabrication of a Kilopixel Array of Superconducting Microcalorimeters with Microstripline Wiring

A document describes the fabrication of a two-dimensional microcalorimeter array that uses microstrip wiring and integrated heat sinking to enable use of high-performance pixel designs at kilopixel scales (32 X 32). Each pixel is the high-resolution design employed in small-array test devices, which consist of a Mo/Au TES (transition edge sensor) on a silicon nitride membrane and an electroplated Bi/Au absorber. The pixel pitch within the array is 300 microns, where absorbers 290 microns on a side are cantilevered over a silicon support grid with 100-micron-wide beams. The high-density wiring and heat sinking are both carried by the silicon beams to the edge of the array. All pixels are wired out to the array edge. ECR (electron cyclotron resonance) oxide underlayer is deposited underneath the sensor layer. The sensor (TES) layer consists of a superconducting underlayer and a normal metal top layer. If the sensor is deposited at high temperature, the ECR oxide can be vacuum annealed to improve film smoothness and etch characteristics. This process is designed to recover high-resolution, single-pixel x-ray microcalorimeter performance within arrays of arbitrarily large format. The critical current limiting parts of the circuit are designed to have simple interfaces that can be independently verified. The lead-to-TES interface is entirely determined in a single layer that has multiple points of interface to maximize critical current. The lead rails that overlap the TES sensor element contact both the superconducting underlayer and the TES normal metal

Chervenak, James↗

Small, Fast TES Microcalorimeters with Unprecedented X-ray Spectral Performance

Driven initially by the desire for X-ray microcalorimeter arrays suitable for imaging the dynamic solar corona, we have developed a transition-edge-sensor (TES) microcalorimeter optimization that exhibits a unique combination of high spectral resolving power and a wide X-ray bandpass. These devices have achieved spectral performance of dE approximately 1.3 eV FWHM at 1.5 keV, 1.6 eV at 6 keV, and 2.0 eV at 8 keV, using small TESs (e.g., approximately 35 micron x 35 micron) that operate in a regime in which the superconducting transition is highly current dependent. In order to accommodate high X-ray count rates, the devices sit directly on a solid substrate instead of on membranes, and we use an embedded heatsinking layer to reduce pixel-to-pixel crosstalk. We will present results from devices with a range of TES and absorber sizes, and from device wafers with varied embedded heatsink materials. This contribution will focus on count-rate capabilities, including a discussion of the trade-off between count rate and energy resolution, and the heatsinking design. We will also present preliminary tests of array readout using a code-division multiplexed SQUID readout scheme, which may be necessary to enable large arrays of these fast devices.

Eckart, M. E.↗

Development of Fast, Background-Limited Transition-Edge Sensors for the Background-Limited Infrared/Sub-Millimetre Spectrograph (BLISS) for SPICA

We report experimental progress toward demonstrating background-limited arrays of membrane-isolated transition-edge sensors (TESs) for the Background Limited Infrared/Sub-mm Spectrograph (BLISS). BLISS is a space-borne instrument with grating spectrometers for wavelengths lambda = 35-435 microns and with R = lambda/(delta)lambda approx. 500. The goals for BLISS TESs are: noise equivalent power (NEP) = 5x10(exp -20) W/Hz(1/2) and response time t<30ms. We expect background-limited performance from bilayers TESs with T(sub c)=65mK and G=15fW/K. However, such TESs cannot be operated at 50mK unless stray power on the devices, or dark power PD, is less than 200aW. We describe criteria for measuring P? that requires accurate knowledge of TC. Ultimately, we fabricated superconducting thermistors from Ir (T(sub c) > or = 135mK) and Mo/Cu proximitized bilayers, where T(sub c) is the thermistor transition temperature. We measured the Ir TES arrays in our 50mK adiabatic demagnetization refrigerator test system, which can measure up to eight 1x32 arrays simultaneously using a time-division multiplexer, as well as our single-pixel test system which can measure down to 15mK. In our previous Ir array measurements our best reported performance was NEP=2.5x10(exp -19) W/Hz(1/2) and tapprox.5ms for straight-beam TESs. In fact, we expected NEPapprox.1.5x10(exp -19)W/Hz(1/2) for meander beam TESs, but did not achieve this previously due to 1/f noise. Here, we detail improvements toward measuring the expected NEP and demonstrate NEP=(1.3+0.2)x10(exp -19)W/Hz(1/2) in our single-pixel test system and NEP=(1.6+0.3)x10(exp -19)W/Hz(1/2) in our array test system.

transition-edge sensors↗

Design of A Transition-Edge-Sensor-Based Thermal Stabilization Stage

Electrothermal feedback in a transition edge sensor suppresses thermal fluctuations in the TES and regions in close thermal contact. We designed a heavily-metallized, leg-isolated membrane with a TES which serves as a thermal stabilization stage that can be lithographically integrated with other devices. Through modeling, fabrication and test of prototype devices, we examine whether the noise reduction in this stage can reduce thermal fluctuations (e.g. 1/f noise) in the other components by providing a more stable base temperature. In one implementation, a leg-isolated TES bolometer of higher superconducting transition temperature (Tc) is encircled by a second membrane region which is metallized and thermally stabilized by a second, lower-Tc TES. We present fabrication results on the dual-Tc design and testing of the simultaneous biasing of a two-stage, two-TES device. We explore varied heat capacity of the thermally stabilized stage in the single pixel design. We also present other designs to evaluate the use of an outer thermal stabilization stage for multiple pixel arrangements.

Rachel Borrelli↗

Development of Fast, Background-Limited Transition-Edge Sensors for the Background-Limited Infrared/Sub-mm Spectrograph (BLISS) for SPICA

We report experimental progress toward demonstrating background-limited arrays of membrane-isolated transition-edge sensors (TESs) for the Background Limited Infrared/Sub-mm Spectrograph (BLISS). BLISS is a space-borne instrument with grating spectrometers for wavelengths lambda=35-435 micron and with R=lambda/delta lambda approximately equals 500. The goals for BLISS TESs are: noise equivalent power (NEP) = 5x10 (sup -20) W/Hz(exp 1/2) and response time tau <30ms. We expect background-limited performance from bilayers TESs with T(sub c) = 65mK and G=15fW/K. However, such TESs cannot be operated at 50mK unless stray power on the devices, or dark power P(sub D), is less than 200aW. We describe criteria for measuring P(sub D) that requires accurate knowledge of TC. Ultimately, we fabricated superconducting thermistors from Ir (T(sub c) >= 135mK) and Mo/Cu proximitized bilayers, where T(sub c) is the thermistor transition temperature. We measured the Ir TES arrays in our 50mK adiabatic demagnetization refrigerator test system, which can measure up to eight 1x32 arrays simultaneously using a time-division multiplexer, as well as our single-pixel test system which can measure down to 15mK. In our previous Ir array measurements our best reported performance was NEP=2.5x10(exp -19) W/Hz(sub 1/2) and Tau approximately equals 5ms for straight-beam TESs. In fact, we expected NEP approximately equals 1.5x10(exp -19)?W/Hz(sup 1/2) for meander beam TESs, but did not achieve this previously due to 1/f noise. Here, we detail improvements toward measuring the expected NEP and demonstrate NEP=(1.3+0.2)x10 (sup -19)W/Hz(exp 1/2) in our single-pixel test system and NEP=(1.6+/-0.3)x10(sup -19)W/Hz(sup 1/2) in our array test system.

infrared spectrometer↗

AC Read-Out Circuits for Single Pixel Characterization of TES Microcalorimeters and Bolometers

SRON is developing Frequency Domain Multiplexing (FDM) for the read-out of transition edge sensor (TES) soft x-ray microcalorimeters for the XMS instrument of the International X-ray Observatory and far-infrared bolometers for the SAFARI instrument on the Japanese mission SPICA. In FDM the TESs are AC voltage biased at frequencies from 0.5 to 6 MHz in a superconducting LC resonant circuit and the signal is read-out by low noise and high dynamic range SQUIDs amplifiers. The TES works as an amplitude modulator. We report on several AC bias experiments performed on different detectors. In particular, we discuss the results on the characterization of Goddard Space Flight Center x-ray pixels and SRON bolometers. The paper focuses on the analysis of different read-out configurations developed to optimize the noise and the impedance matching between the detectors and the SQUID amplifier. A novel feedback network electronics has been developed to keep the SQUID in flux locked loop, when coupled to superconducting high Q circuits, and to optimally tune the resonant bias circuit. The achieved detector performances are discussed in view of the instrument requirement for the two space missions.

Gottardi, L.↗

The Athena/X-IFU, from Detector Development to Scientific Feasibility Studies via Simulations

The investigation of the physical hot and energetic phenomena in the Universe will further improve our understanding of the assembly of the largest structures and massive halos of galaxies, and of the role of black holes in shaping the Universe as we see it. Spatially resolved X-ray high-resolution spectroscopy will be a crucial tool to achieve these scientific goals. The X-IFU instrument onboard the Athena observatory will provide us with these capabilities through the use of arrays of Transition edge microcalorimeters detectors. These superconducting devices will deliver the required exquisite spectral resolution needed to achieve the core science objectives, such as the characterization of turbulence and bulk motions in the hot gaseous atmospheres of groups and clusters of galaxies in order to unveil the process of large scale structures assembly. I will present the Transition Edge Sensors principle, the status of the instrumental development for the X-IFU instrument, and discuss their performance in view of the scientific objectives of the Athena mission. I will further present the case of a feasibility study and optimisation of the observing strategy for the characterization of the internal dynamics of the intra-cluster medium, through the use of mock simulations of observations with the X-IFU instrument.

Sophie Beaumont↗

Characterization of Transition Edge Sensors for the Simons Observatory

The Simons Observatory is building both large (6 m) and small (0.5 m) aperture telescopes in the Atacama Desert in Chile to observe the cosmic microwave background CMB radiation with unprecedented sensitivity. Simons Observatory telescopes in total will use over 60,000 transition edge sensor (TES) detectors spanning center frequencies between 27 and 285 GHz and operating near 100 mK. TES devices have been fabricated for the Simons Observatory by NIST, Berkeley, and HYPRES/SeeQC corporation. Iterations of these devices have been tested cryogenically in order to inform the fabrication of further devices, which will culminate in the final TES designs to be deployed in the field. The detailed design specifications have been independently iterated at each fabrication facility for particular detector frequencies. We present test results for prototype devices, with emphasis on NIST high frequency detectors. A dilution refrigerator was used to achieve the required temperatures. Measurements were taken both with 4-lead resistance measurements and with a time-domain Superconducting Quantum Interference Device (SQUID) multiplexer system. The SQUID readout measurements include analysis of current versus voltage (IV) curves at various temperatures, square wave bias step measurements, and detector noise measurements. Lastly, normal resistance, superconducting critical temperature, saturation power, thermal and natural time constants, and thermal properties of the devices are extracted from these measurements.

47 OTHER INSTRUMENTATION↗

Microwave Multiplexing on the Keck Array

In this paper, we describe an on-sky demonstration of a microwave-multiplexing readout system in one of the receivers of the Keck Array, a polarimetry experiment observing the cosmic microwave background at the South Pole. During the austral summer of 2018–2019, we replaced the time-division multiplexing readout system with microwave-multiplexing components including superconducting microwave resonators coupled to radio frequency superconducting quantum interference devices at the sub-Kelvin focal plane, coaxial-cable plumbing and amplification between room temperature and the cold stages, and a SLAC Microresonator Radio Frequency system for the warm electronics. In the range 5–6 GHz, a single coaxial cable reads out 528 channels. The readout system is coupled to transition-edge sensors, which are in turn coupled to 150-GHz slot-dipole phased-array antennas. Observations began in April 2019, and we report here on an initial characterization of the system performance.

79 ASTRONOMY AND ASTROPHYSICS↗

Design of Magnetic Shielding and Field Coils for a TES X-Ray Microcalorimeter Test Platform

The performance of transition-edge sensors (TES) and their SQUID multiplexed readouts is very sensitive to ambient magnetic field and its fluctuations. In order to run ground experiments on thousands of X-ray TES microcalorimeters with a small uniform ambient magnetic field (< 1 μT, with a uniformity < 0.1 μT), we need a very low ambient field to be trapped into the superconducting magnetic shields. We have designed a sub-Kelvin test platform to reach these specifications. For this purpose, we modeled a new design for the shielding consisting of a series of different mu-metal and superconducting shields, including a niobium shield at 50 mK, a cryoperm (A4K) shield at 3 K, and a mu-metal shield at 300 K. A magnetic field coil is used to vary the local perpendicular magnetic field over the TES array. To optimize this field, we have studied a number of different field-coil designs and the impact of the different shield geometries, in order to reach the required field uniformity.

Miniussi, Antoine R.↗