Measurements of source emittance and beam coherence properties of the upgraded Advanced Photon Source

The Advanced Photon Source (APS) has been upgraded with a multi-bend achromat lattice, achieving significantly reduced electron beam emittance and enhanced X-ray coherence. Precise characterization of these properties is essential for optimizing beamline performance and enabling new experiments that take full advantage of the upgraded source. We report on measurements of source size and transverse coherence properties using grating interferometry at two beamlines: the APS 3-ID-B undulator beamline and the 1-BM-B bending magnet beamline. The results confirm the world-record horizontal emittance of the upgraded APS below 30 pm rad and validate the theoretical design parameters. We further investigate the impact of optical aberrations and mechanical vibrations at the 12-ID-C beamline on coherence preservation. These measurements establish a benchmark for future beamline enhancements and demonstrate the effectiveness of grating interferometry for high-precision beam characterization. Our findings provide critical insights into synchrotron beam dynamics, coherence degradation mechanisms, and strategies for optimizing beamline X-ray optics at next-generation light sources.

Advanced Photon Source↗

Multimodal, Multidimensional, and Multiscale X-ray Imaging at the National Synchrotron Light Source II

Over the last couple of decades, the synchrotron radiation research community has witnessed tremendous advancement in the field of x-ray imaging and microscopy. Continuing enhancement of the light sources’ brightness, advances in x-ray focusing optics, incorporation of precision instruments, and development of innovative imaging techniques are some of the leading contributors for the rapid progress. New imaging and microscopy beamlines, such as the ones at the National Synchrotron Light Source II (NSLS-II), a Department of Energy (DOE) Office of Science user facility located at DOE’s Brookhaven National Laboratory, are capable of performing more sophisticated and complicated measurements than ever before, either on their own or used together as a suite of tools. These sophisticated and complex measurements exhibit attributes for multimodal, multidimensional, and multiscale imaging. Recent popularity of these methods is strongly driven by the current trends in materials characterizations, where researchers desire to map out hierarchical materials structure over a large range of length scales, to understand structure-property correlation, to quantify materials structures in 3D, and/or to perform operando or in situ experiments. It is important to emphasize that “materials” under investigation are not only synthesized materials but also the natural materials. In this article, we describe multimodal, multidimensional and multiscale x-ray imaging capabilities of the NSLS-II beamlines and how these methods are used to tackle complex scientific problems.

47 OTHER INSTRUMENTATION↗

Manufacturability-based optical design optimization for advanced Kirkpatrick–Baez X-ray focusing mirrors

The advanced Kirkpatrick–Baez (AKB) mirror setup is an effective and compelling solution to provide stable X-ray nano-focusing for synchrotron radiation or free-electron laser beamlines. We propose an AKB mirror design optimization approach to mitigate the difficulties associated with mirror fabrication by minimizing the total slope ranges of the four curved mirrors while achieving the expected focusing performance. In the optimization, we have considered geometry constraints to ensure the beam acceptance with the required clear aperture, the diffraction-limited focal size with the adequate numerical aperture, and the desired mirror gaps for adjustment and the necessary working distance for the sample stage. Additionally, practical constraints linked to mirror metrology and fabrication, such as mirror length limits and curvature uncertainty in measurement, are taken into account. Furthermore, progressive objective optimization eliminates the need for any initial guess, fully automating the AKB optimization process. This approach facilitates the development of an elegant Wolter-I or Wolter-III type AKB design solution that satisfies these multiple constraints. In cases where constraints cannot be simultaneously satisfied, the optimization results provide valuable insights into areas where trade-offs need to be considered. Simulations with ray tracing and wavefront propagation validate the optimized AKB design showing high tolerance to the beam incident angle.

36 MATERIALS SCIENCE↗

Effect of a Synchrotron X-ray Microtomography Imaging Experiment on the Amino Acid Content of a CM Chondrite

X-ray microcomputed tomography and synchrotron X-ray microcomputed tomography (μCT) are becoming popular tools for the reconnaissance imaging of chondrites. However, there are occasional concerns that the use of μCT may be detrimental to organic components of a chondrite. Soluble organic compounds represent ~2–10% of the total solvent extractable carbon in CI and CM carbonaceous chondrites and amino acids are among the most abundant compounds in the soluble organic fraction. We irradiated two samples of the Murchison CM2 carbonaceous chondrite under conditions slightly harsher (increased beam exposure time) than those typically used for x-ray μCT imaging experiments to determine if detectable changes in the amino acid abundance and distribution relative to a nonexposed control sample occurred. After subjecting two meteorite portions to ionizing radiation dosages of 1.1 kiloGray (kGy) and 1.2 kGy with 48.6 and 46.6 keV monochromatic X-rays, respectively, we analyzed the amino acid content of each sample. Within analytical errors, we found no differences in the amino acid abundances or enantiomeric ratios when comparing the control samples (nonexposed Murchison) and the irradiated samples. We show with calculations that any sample heating due to x-ray exposure is negligible. We conclude that a monochromatic synchrotron X-ray μCT experiment at beamline 13-BM-D of the Advanced Photon Source, which imparts ~1 kGy doses, has no detectable effect on the amino acid content of a carbonaceous chondrite. These results are important for the initial reconnaissance of returned samples from the OSIRIS-REx and Hayabusa 2 asteroid sample return missions.

Jon M. Friedrich↗

Simulations of coherent scattering experiments at storage ring synchrotron radiation sources in the hard x-ray range

Detailed simulations of experiments carried out at modern light sources are directly related to the most efficient and productive use of these facilities for research in multiple branches of science and technology. The “Synchrotron Radiation Workshop” computer code with its Python interface, and Sirepo web-browser-based graphical user interface, currently supports physical optics simulations of coherent X-ray scattering and imaging experiments on user-defined virtual samples. We present examples of simulations of coherent scattering experiments that are typically performed at the Coherent Hard X-ray beamline at Brookhaven National Laboratory’s (BNL) National Synchrotron Light Source II. We also present several comparisons of the simulations with the results of actual coherent X-ray scattering experiments with nano-fabricated test samples produced at BNL’s Center for Functional Nanomaterials.

36 MATERIALS SCIENCE↗

Beamline Electrostatic Levitator (BESL) for in-situ High Energy K-Ray Diffraction Studies of Levitated Solids and Liquids at High Temperature

Determinations of the phase formation sequence, the crystal structures and the thermodynamic properties of materials at high temperatures are difficult because of contamination from the sample container and environment. Containerless processing techniques, such as electrostatic (ESL), electromagnetic (EML), aerodynamic, and acoustic levitation, are most suitable these studies. An adaptation of ESL for in-situ structural studies of a wide range of materials, including metals, semiconductors, insulators using high energy (125 keV) synchrotron x-rays is described here. This beamline ESL (BESL) allows the in-situ determination of the atomic structures of equilibrium solid and liquid phases, including undercooled liquids, as well as real-time studies of solid-solid and liquid-solid phase transformations. The use of image plate (MAR345) or GE-Angio detectors enables fast (30 ms - 1s) acquisition of complete diffraction patterns over a wide q-range (4 - 140/mm). The wide temperature range (300 - 2500 K), containerless processing under high vacuum (10(exp -7) - 10(exp -8) torr), and fast data acquisition, make BESL particularly suitable for phase diagram studies of high temperature materials. An additional, critically important, feature of BESL is the ability to also make simultaneous measurement of a host of thermo-physical properties, including the specific heat, enthalpy of transformation, solidus and liquidus temperatures, density, viscosity, and surface tension; all on the same sample and simultaneous with the structural measurements.

Gangopadhyay, A. K.↗

Detailed diffraction imaging of x-ray optics crystals with synchrotron radiation

Rocking curve topography at the Advanced Photon Source’s beamline 1-BM measures the x-ray reflection from large (many cm 2 ) flat crystals on a sub-mm scale with microradian angular resolution. The $(01\bar{1}1)$ reflection at 8 keV is uniform across the crystal and close to theory for three thick quartz wafers well-polished with increasingly finer grit. However, the reflection is non-uniform for some ~ 0.1mmthin, bendable crystals that are made flat by optical contact with a flat substrate. Here, these thin crystals are bent to serve in certain x-ray diagnostics of plasmas, and similar non-uniformities could then occur in bent crystals as well. The same detail in x-ray reflection in bent crystals is unachievable with the existing topography setup: one way to get the desired resolution is with a standard microfocusing approach.

47 OTHER INSTRUMENTATION↗

CoSyR: A novel beam dynamics code for the modeling of synchrotron radiation effects

The self-consistent nonlinear dynamics of a relativistic charged particle beam interacting with its complete self-fields is a fundamental problem underpinning many of the accelerator design issues in high brightness beam applications, as well as the development of advanced accelerators. Particularly, synchrotron radiation induced effects in a magnetic dispersive beamline element can lead to collective beam instabilities and emittance growth. A novel beam dynamics code is developed based on a Lagrangian method for the calculation of the particles’ radiation near-fields using wavefront/wavelet meshes via the Green’s function of the Maxwell equations. These fields are then interpolated onto a moving mesh for dynamic update of the beam. This method allows radiation co-propagation and self-consistent interaction with the beam in 2D/3D simulations at greatly reduced numerical errors. Multiple levels of parallelisms are inherent in this method and implemented in our code CoSyR to enable at-scale simulations of nonlinear beam dynamics on modern computing platforms using MPI, multi-threading, and GPUs. Here, the current 2D implementation of CoSyR has been used to evaluate the transverse and longitudinal coherent radiation effects on the beam and to investigate beam optics designs proposed for mitigation of beam brightness degradation in a magnetic bunch compressor. In this paper, the design of CoSyR, as well as the benchmark with other coherent synchrotron radiation models, are described and discussed. Extension of the core algorithms to 3D is possible and planned.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Dose Measurement and Monte Carlo FLUKA simulations for the FE and FOE of the 27-ID HEX Beamline

The 27-ID High Energy Engineering X-ray Scattering (HEX) beamline, commissioned in 2024, operates within the Hard X-ray Scattering and Spectroscopy program at Brookhaven Lab’s National Synchrotron Light Source II (NSLS-II). The high energy spectrum at the HEX beamline extends up to several hundred keV, making it well suited for applications such as imaging large engineering samples, including fully assembled batteries, fuel cells, etc.

43 PARTICLE ACCELERATORS↗

Evaluation of an event-driven 3FI ASIC for spectroscopic X-ray detection with synchrotron radiation

The novel design and evaluation on the NSLS-II beamline of the 3FI application-specific integrated circuit (ASIC) bump-bonded to a simple, planar, 2D segmented silicon sensor are presented. The ASIC was developed for full-field fluorescence spectral X-ray imaging (3FI). It is a small-scale prototype that features a square array of 32 × 32 pixels, and the size of the pixels is 100 µm × 100 µm. The ASIC was implemented in a 65 nm CMOS integrated circuit fabrication process. Each pixel incorporates a charge-sensitive amplifier, a shaping filter, a discriminator, a peak detector and a sample-and-hold circuit, allowing detection of events and storage of signal amplitudes. The system operates in a frameless event-driven readout mode, outputting analog values for threshold-triggered events, allowing high-speed multi-element X-ray fluorescence data acquisition. The 3FI ASIC achieves per-channel spectrometric performance at a power consumption of only 200 µW per pixel, with nearly all dissipation confined to the analog front-end. An energy resolution is measured at the level of 308 eV full width at half-maximum (FWHM) at 8.04 keV (Cu Kα), and 138 eV FWHM at 3.69 keV (Ca Kα). This per-pixel capability makes the prototype suitable for in situ trace element microanalysis in biological and environmental studies. Moreover, the frameless architecture of the detector is designed to address limitations of conventional X-ray fluorescence microscopy, which typically requires mechanical scanning, by enabling continuous high-throughput data acquisition in future full-field implementations.

47 OTHER INSTRUMENTATION↗

Developments in SRW Code and Sirepo Framework Supporting Simulation of Time-Dependent Coherent X-ray Scattering Experiments

Physical optics simulations for beamlines and experiments are essential for the effective use of synchrotron light source facilities such as NSLS-II at BNL. The SRW software package supports such source-to-detector simulations for coherent X-ray scattering and imaging experiments through its Python interface and Sirepo browser-based graphical user interface. This allows one to define custom sample models, assess the feasibility of an experiment, and estimate most appropriate beamline settings before using valuable beamtime. We discuss the recent use of general-purpose GPU resources and coherent mode decomposition algorithms in SRW to accelerate physical optics simulations with partially coherent X-rays. To illustrate these new capabilities, we describe simulations of typical time series of partially coherent scattering images used in X-ray Photon Correlation Spectroscopy (XPCS) experiments; aiming to characterize the nanoscale dynamics of a disordered sample, representing a solution of nanoparticles undergoing Brownian diffusion.

36 MATERIALS SCIENCE↗

Type 2 diabetes impairs annulus fibrosus fiber deformation and rotation under disc compression in the University of California Davis type 2 diabetes mellitus (UCD-T2DM) rat model

Abstract Understanding the biomechanical behavior of the intervertebral disc is crucial for studying disease mechanisms and developing tissue engineering strategies for managing disc degeneration. We used synchrotron small-angle X-ray scattering to investigate how changes to collagen behavior contribute to alterations in the disc’s ability to resist compression. Coccygeal motion segments from 6-month-old lean Sprague-Dawley rats ( n=7) and diabetic obese University of California Davis type 2 diabetes mellitus (UCD-T2DM) rats ( n=6, diabetic for 68±7 days) were compressed during simultaneous synchrotron scanning to measure collagen strain at the nanoscale (beamline 7.3.3 of the Advanced Light Source). After compression, the annulus fibrosus was assayed for nonenzymatic cross-links. In discs from lean rats, resistance to compression involved two main energy-dissipation mechanisms at the nanoscale: (1) rotation of the two groups of collagen fibrils forming the annulus fibrosus and (2) straightening (uncrimping) and stretching of the collagen fibrils. In discs from diabetic rats, both mechanisms were significantly impaired. Specifically, diabetes reduced fibril rotation by 31% and reduced collagen fibril strain by 30% (compared to lean discs). The stiffening of collagen fibrils in the discs from diabetic rats was consistent with a 31% higher concentration of nonenzymatic cross-links and with evidence of earlier onset plastic deformations such as fibril sliding and fibril–matrix delamination. These findings suggest that fibril reorientation, stretching, and straightening are key deformation mechanisms that facilitate whole-disc compression, and that type 2 diabetes impairs these efficient and low-energy elastic deformation mechanisms, thereby altering whole-disc behavior and inducing the earlier onset of plastic deformation.

Rosenberg, James L.↗

Data-driven modeling and control of an X-ray bimorph adaptive mirror

Adaptive X-ray mirrors are being adopted on high-coherent-flux synchrotron and X-ray free-electron laser beamlines where dynamic phase control and aberration compensation are necessary to preserve wavefront quality from source to sample, yet challenging to achieve. Additional difficulties arise from the inability to continuously probe the wavefront in this context, which demands methods of control that require little to no feedback. In this work, a data-driven approach to the control of adaptive X-ray optics with piezo-bimorph actuators is demonstrated. This approach approximates the non-linear system dynamics with a discrete-time model using random mirror shapes and interferometric measurements as training data. For mirrors of this type, prior states and voltage inputs affect the shape-change trajectory, and therefore must be included in the model. Without the need for assumed physical models of the mirror's behavior, the generality of the neural network structure accommodates drift, creep and hysteresis, and enables a control algorithm that achieves shape control and stability below 2 nm RMS. Using a prototype mirror and ex situ metrology, it is shown that the accuracy of our trained model enables open-loop shape control across a diverse set of states and that the control algorithm achieves shape error magnitudes that fall within diffraction-limited performance.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Compact, portable, automatic sample changer stick for cryostats and closed-cycle refrigerators

Beamlines are facilities that produce and deliver highly focused and intense beams of radiation, typically x rays, synchrotron radiation, or neutrons, for scientific research purposes. Millions of dollars are spent annually to maintain and operate these scientific beamlines, oftentimes running continuously between cycles. To reduce human intervention and improve productivity, mechanical sample changers are often commissioned for use. Designing sample changers is difficult because mechanical parts can be bulky, expensive, and challenging to design for instruments with low volume access, high radiation, and cryogenic environments. We present a portable and inexpensive sample changer stick that can hold and manipulate up to four samples, specifically designed for use with cryogenic closed-cycle refrigerators. The sample changer stick enables rapid and efficient exchange of samples without manual intervention, and is compatible with standard sample mounts such as vanadium cans. The sample changer stick includes a motorized rotation and lancing mechanism, which enables the precise positioning of each sample in the neutron beam, while ensuring compatibility with the operating temperatures and vacuum conditions required for closed-cycle refrigerators. The design has been successfully tested at the VISION beamline at the Spallation Neutron Source. The mechanical action and software controls are detailed. Furthermore, the sample changer stick is a valuable tool for scientists working with cryogenic closed-cycle refrigerators.

36 MATERIALS SCIENCE↗

Preface to the JPCM special issue on intense radiation sources in condensed matter and materials physics

This special issue is designed to honour the contributions of our colleague Neville Greaves who was among the first to apply newly-available synchrotron x-ray techniques to study the synthesis, structures and properties of advanced materials [1, 2]. His wide ranging work on ceramics, glasses and nanomaterials was celebrated in a recent issue of the J. Non-Cryst. Solids [3]. Neville's contributions to synchrotron research, highlighted here, focussed on design and construction of new beamline capabilities and sample environments to probe materials under different physical and chemical conditions, integrating various techniques to obtain complementary data on structure and bonding. The innovative nature of his work is illustrated by his studies of liquids and glasses, where he incorporated aerodynamic levitation into these experimental techniques, using both synchrotron x-ray and neutron beams to probe the structural transformations and dynamics combined with molecular dynamics simulations to study atomic scale organisation. His work has had a major impact on fundamental condensed matter physics and chemistry as well as applied materials science; and in this issue, we present contributions from colleagues using and developing new experimental techniques at current and next-generation synchrotron, neutron and free-electron laser sources and in their own laboratories, that probe the fundamental physics, chemistry and functional properties of novel materials and processes.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Another step of the APXPS evolution taken at MAX IV synchrotron

In the past several decades, X-ray photoelectron spectroscopy (XPS) has been established as a versatile tool to investigate chemical and electronic properties of materials. Its principle is based on a photoelectric effect, which was discovered by Hertz (1887) and explained later by Einstein (1905). However, a practical technical implementation of the technique had to wait until the 1950s, when Siegbahn et al. carried out their first pioneering experiments (Siegbahn & Svartholm, 1946).

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Constrained non-negative matrix factorization enabling real-time insights of in situ and high-throughput experiments

Non-negative matrix factorization (NMF) is an appealing class of methods for performing unsupervised learning on streaming spectral data, particularly in time-sensitive applications such as in situ characterization of materials. These methods seek to decompose a dataset into a small number of components and weights that can compactly represent the underlying signal while effectively reconstructing the observations with minimal error. However, canonical NMF methods have no underlying requirement that the reconstruction uses components or weights that are representative of the true physical processes. In this work, we demonstrate how constraining a subset of the NMF weights or components as rigid priors, provided as known or assumed values, can provide significant improvement in revealing true underlying phenomena. We present a PyTorch-based method for efficiently applying constrained NMF and demonstrate its application to several synthetic examples. Our implementation allows an expert researcher-in-the-loop to provide and dynamically adjust the constraints during a live experiment involving streaming spectral data. Such interactive priors allow researchers to specify known or identified independent components, as well as functional expectations about the mixing or transitions between the components. We further demonstrate the application of this method to measured synchrotron x-ray total scattering data from in situ beamline experiments. In such a context, constrained NMF can result in a more interpretive and scientifically relevant decomposition than canonical NMF or other decomposition techniques. As a result, the details of the method are provided, along with general guidance for employing constrained NMF in the extraction of critical information and insights during time-sensitive experimental applications.

36 MATERIALS SCIENCE↗

Harmonic suppression gratings for soft X-ray monochromators

We describe an approach to harmonic suppression in soft X-ray monochromators by engineering the reflection grating’s diffraction pattern to approximate a sinusoidal amplitude. At synchrotron and free-electron laser sources, X-ray beamlines powered by insertion devices produce a spectrum containing harmonic photon energies that can couple unwanted light into experiments. Beamlines in the soft X-ray energy range (100 eV to 2 keV) commonly employ energy-filtering elements to suppress these harmonics. Available approaches tend to be inefficient, significantly reducing the transmitted power. We show that with pseudo-grayscale binary halftone patterns, gratings can approximate a sinusoidal amplitude and suppress higher diffraction orders. Prototype demonstrations of lithographically fabricated gratings were conducted on a soft X-ray beamline with photon energies of 110 eV and 330 eV. Relative to a square-wave amplitude grating, the third-harmonic intensity was reduced by a factor of 9.0 with a first-order efficiency reduction of 38%.

Goldberg, Kenneth A. [Lawrence Berkeley National L↗