Disassembly and Initial Post-Irradiation Examination of the Mini99 Experiment

The Miniature Fuel Molybdenum-99 (Mini99) experiment is a first-of-a-kind experiment in the High Flux Isotope Reactor. Mini99 is the first MiniFuel irradiation experiment to use liquid metal inside the MiniFuel subcapsule for additional temperature control. In this work, the initial post-irradiation examination is reported. As-built simulations were conducted and compared with designs, and physical post-irradiation examinations were conducted to determine actual test temperatures via SiC thermometry samples, to evaluate the extent of fission gas release from the samples, and to remove the fuel from the subcapsules. As-built simulations compared well with experiment designs and were in reasonable agreement with the measured temperatures inferred from the passive SiC thermometers. Additionally, fission gas release values were relatively small (on the order of 3%); one sample reached approximately 8%. Although some of this behavior is attributable to recoil, most of the gas release was likely caused by the physics of the fuel behavior during the test. Finally, disassembly showed that at least four of the fuel samples degraded into small components and granules at some point during the test, with the state of the other two samples unproven. Additional work is planned for further examination of these samples via various microscopy techniques.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

A tunable autonomous RNA-fueled micro-engine

Autonomous molecular machines capable of converting chemical energy into mechanical motion are foundational components for synthetic nanoscale systems. Inspired by biological motors, we report the construction of a tunable, RNA-fueled DNA origami engine that drives the cyclic movement of a 500 nm-diameter particle at the microscale. The engine operates via sequential RNA–DNA hybridization and enzymatic cleavage by RNase H, enabling reversible switching between folded and unfolded conformations without external intervention. By modulating RNA and enzyme concentrations and controlling temperature, we achieve tunable switching kinetics, with transition periods as short as ~10 s. Kinetic modeling reveals that the folding pathway is governed by both productive RNA binding and the enzymatic clearance of misfolded intermediates, while unfolding is primarily controlled by RNase H activity. Since the RNA fuel binds specifically to the DNA strands, each engine is addressable simply by changing the sequences. This work demonstrates a programmable, self-resetting molecular actuator and offers a blueprint for building more complex nanomechanical systems with forces and energies comparable to molecular motors.

DNA nanomachines↗

Integration of pH Control into Chi.Bio Reactors and Demonstration with Small-Scale Enzymatic Poly(ethylene terephthalate) Hydrolysis

Small-scale bioreactors that are affordable and accessible would be of major benefit to the research community. In previous work, an open-source, automated bioreactor system was designed to operate up to the 30 mL scale with online optical monitoring, stirring, and temperature control, and this system, dubbed Chi.Bio, is now commercially available at a cost that is typically 1–2 orders of magnitude less than commercial bioreactors. In this work, we further expand the capabilities of the Chi.Bio system by enabling continuous pH monitoring and control through hardware and software modifications. For hardware modifications, we sourced low-cost, commercial pH circuits and made straightforward modifications to the Chi.Bio head plate to enable continuous pH monitoring. For software integration, we introduced closed-loop feedback control of the pH measured inside the Chi.Bio reactors and integrated a pH-control module into the existing Chi.Bio user interface. We demonstrated the utility of pH control through the small-scale depolymerization of the synthetic polyester, poly(ethylene terephthalate) (PET), using a benchmark cutinase enzyme, and compared this to 250 mL bioreactor hydrolysis reactions. The results in terms of PET conversion and rate, measured both by base addition and product release profiles, are statistically equivalent, with the Chi.Bio system allowing for a 20-fold reduction of purified enzyme required relative to the 250 mL bioreactor setup. Through inexpensive modifications, the ability to conduct pH control in Chi.Bio reactors widens the potential slate of biochemical reactions and biological cultivations for study in this system, and may also be adapted for use in other bioreactor platforms.

09 BIOMASS FUELS↗

Reversible Binding Interfaces Made of Microstructured Polymer Brushes

The polymer brush architecture of the end-tethered polymer molecules is one of the most widely used efficient methods to regulate interfacial interactions in colloidal systems found in live matter and manufactured materials. Emerging applications of polymer brush structures require solutions to new tasks in the control of interfacial interactions. The rapid development of live cell manufacturing relies on scalable and efficient cell harvesting methods. Stimuli-responsive surfaces made of surface-grafted poly(N-isopropylacrylamide) (PNIPAM) can bind and detach the adherent cell upon changes in temperature and have been used for cell growth and harvesting. The applications are limited by the requirement to satisfy a range of PNIPAM coating characteristics that depend on the dimensions of the integrin complex in the cell membrane and the basal surface. The analysis of the microstructured surfaces, when adhesive and disjoining functions of the microdomains are decoupled, shows that many limitations of PNIPAM one-component coatings can be avoided by using a much broader range of structural characteristics of the microstructured interfaces composed of alternating disjoining PNIPAM domains and adhesive polymeric domains with cell-affinity functional groups. Temperature-controlled reversible adhesion to such microstructured interfaces is studied here experimentally with model systems of solid spherical particles and by employing simulations for solid and soft membranes interacting with the microstructured surfaces to mimic interactions with soft and solid disk-like particles.

36 MATERIALS SCIENCE↗

Master Oscillator and Phase Reference Line Design for the PIP-II Linac

The phase averaging reference line system provides the RF phase reference, LO and clock signals to the LLRF and other accelerator sub-systems. The PIP-II linac has RF systems at three frequencies - 162.5 MHz, 325 MHz and 650 MHz. A temperature-stabilized, low-phase-noise oscillator is used as the master oscillator. Phase reference signals at 162.5 MHz, 325 MHz, and 650 MHz, along with LO signals at 182.5 MHz, 345 MHz, 670 MHz and LLRF clocks at 1320 MHz and 1300 MHz, are generated in temperature-controlled RF modules at each frequency section. A phase reference from each module travels to the next section, where it is doubled to produce required frequencies. The reference also travels alongside the accelerating cavities in the tunnel, allowing cavity probe and reference cables to temperature track and reduce measurement errors from temperature changes or phase drift.

Syed, A. [Fermilab]↗

Thermalization at low temperatures via weakly damped multisite baths

We study the thermalization properties of one-dimensional open quantum systems coupled to baths at their boundary. The baths are driven to their thermal states via Lindblad operators, while the system undergoes Hamiltonian dynamics. We specifically consider multisite baths and investigate the extent to which the late-time steady state resembles a Gibbs state at some controllable temperature set by the baths. We study three models: a noninteracting fermion model accessible via free-fermion technology, and two interacting models, the XZ model and the chiral clock model, which are accessible via tensor network methods. We show that, by tuning towards the weak coupling and slow relaxation limits, one can engineer low temperatures in the bulk of the system provided the bath size is big enough. Here, we use this capability to study energy transport in the XZ model at lower temperatures than previously reported. Our work paves the way for future studies of interacting open quantum systems at low temperatures.

1-dimensional spin chains↗

Fermilab PIP-II Master Oscillator and Precision Reference Line Design and Construction

The phase averaging reference line system pro- vides the RF phase reference, LO and clock sig- nals to the LLRF and other accelerator sub- systems. The PIP-II linac has RF systems at three frequencies – 162.5 MHz, 325 MHz and 650 MHz. A temperature-stabilized, low-phase- noise oscillator is used as the master oscil- lator. Phase reference signals at 162.5 MHz, 325 MHz, and 650 MHz, along with LO signals at 182.5 MHz, 345 MHz, 670 MHz and LLRF clocks at 1320 MHz and 1300 MHz, are generated in temperature-controlled RF modules at each fre- quency section. A phase reference from each module travels to the next section, where it is doubled to produce required frequencies. The reference also travels alongside the accelerating cavities in the tunnel, allowing cavity probe and reference cables to temperature track and reduce measurement errors from temperature changes or phase drift.

Syed, Ahmed [Fermilab]↗

Thermal Studies of CMS High-Granularity Calorimeter (HGCAL) Cassettes for the HL-LHC Upgrade

The CMS High Granularity Calorimeter (HGCAL) is a key endcap upgrade for the High-Luminosity LHC, designed to operate in an environment of extreme radiation and high particle rates. Each HGCAL cassette integrates silicon and scintillator modules, front-end ASICs, and a copper cooling plate that provides both mechanical integrity and thermal coupling using two-phase CO₂ cooling. Stable and uniform temperature control is essential to ensure reliable performance of the front-end electronics and to limit radiation-induced leakage currents in the silicon sensors. We present results from thermal characterization studies of pre-series HGCAL cassettes assembled and tested at Fermilab. Embedded RTD/PT1000 temperature sensors were used to measure gradients across copper cooling plates, module layers, and cassette edges under powering conditions representative of operation. The measured thermal behavior demonstrates effective heat transport through the cassette stack and highlights small but systematic variations correlated with geometry and assembly tolerances. These results validate the cooling performance of HGCAL cassettes.

Wang, Jinglu [Northwestern U.]↗

Ex-situ Heat Treatment of TEM Foils in a Custom Titanium Fixture: A Case Study on Ni-based Superalloy

The advancement of microstructural characterization at the nanoscale is critical to understanding the microstructural evolution and performance of engineering materials. Transmission electron microscopy (TEM) plays a vital role in such investigations, particularly when coupled with controlled ex- and in-situ experiments. In this study, we introduce a novel method for ex-situ heat treatment (HT) of TEM foils using a custom-designed fixture, made from pure titanium, and vacuum furnace to inhibit oxidation. This approach ensures precise temperature control and minimal sample contamination during HT, critical for substructural characterization and analysis of metallic materials. The fixture consists of a titanium base with three slits, for three sample foils, and a titanium cap for closure. The entire assembly is placed in a vacuum heat treatment furnace with high vacuum capability to prevent oxidation. To validate the effectiveness of the setup, precipitation behavior and microstructural changes were studied in an IN725 variant heat-treated at 500°C for 1 hour and 282 variant heat-treated at 700°C for 1 hour, as case studies.

electron microscopy↗

Catalysts by pyrolysis: Direct observation of chemical and morphological transformations leading to transition metal-nitrogen-carbon materials

Transition metal-nitrogen-carbon materials (M-N-C catalysts) are promising electrocatalysts in polymer electrolyte fuel cells (PEFCs) and electrolyzer applications. High temperature treatment in inert atmosphere (pyrolysis) is the essential, most common method for the synthesis of M-N-C catalysts and critical to achieve high electrocatalytic activity and electronic conductivity. To this day, despite many uses and successful implementations in materials manufacturing, pyrolysis has been an entirely empirical technology, with process control and optimization relying exclusively on “Edisonian” approach. The knowledge gap in the mechanism about how the precursor is being transformed into catalysts hinders further development of the M-N-C catalysts regardless of the precursor class and processing protocols. In this work, we probed the morphological evolution and chemical transformation of a nitrogen-containing charge transfer organic salt, mixed with transition metal (iron) salt and amorphous silica powder (precursor) during the pyrolysis process via a combination of in situ synchrotron and laboratory-based diagnostic techniques. The pyrolysis process is found to be divided into three stages. During a controlled temperature ramp, the selected organic N-C precursor (nicarbazin) began melting and decomposing just below 400 °C, forming a certain number of micrometer-scale pores and pathways. With increase in temperature from 400 °C to 900 °C, amorphous carbon domains started forming, and reduced (metallic) iron nanoclusters appeared, being dispersed uniformly throughout the carbonaceous matrix. When temperature advanced above 900 °C, graphitization of carbon commenced, associated with appearance and evolution of atomically dispersed metal-nitrogen moieties in the carbonaceous matrix. As the graphitization advanced further, a secondary process of agglomeration of metal nanoparticles occurred. Multi-analytical technique observations conducted here provide a base for rational design and optimization of M-N-C electrocatalysts via pyrolysis.

36 MATERIALS SCIENCE↗

Review of liquid desiccant air dehumidification systems coupled with heat pump: System configurations, component design, and performance

Vapor Compression Systems (VCS) are the most common air conditioning technology. VCS cool the air to its dew point temperature (overcooling) to remove water vapor in the air through condensation and then reheats the air back to the comfort temperature for direct use. The VCS process is inefficient due to overcooling and reheating. Liquid Desiccant Dehumidification (LDD) is a potentially energy-efficient air conditioning. LDD removes water vapor in the process air using liquid desiccant’s high-water affinity. It hybrids with sensible cooling to control temperature and humidity separately. The LD in the LDD becomes weak after dehumidification. The LDD needs additional heating to regenerate the weak Liquid Desiccant (LD) to a high concentration for dehumidification. Earlier versions of the LDD systems use highly concentrated liquid desiccant (large water removal capability) to dehumidify the air by only dealing with latent load. It leads to highly elevated temperatures above 60 °C of heat sources (combustion or electric resistance-based heating) for regeneration. The energy needed for the elevated temperature heat resource significantly reduces or demolishes the benefit of LDD systems. In the recent two decades, researchers have investigated a new configured LDD system that couples an LDD with a heat pump at both dehumidification and regeneration sides for better efficiency. The heat pump provides cooling (from the evaporator) for both dehumidification and sensible cooling and simultaneous heating from the condenser for regeneration. The highly integrated system (HP-LDD) with improved efficiency enables the LDD to operate at lower concentrations and temperatures in dehumidification and regeneration. This paper depicts the working principle behind HP-LDD and its heating and cooling requirements. It reviews the comparison between the HP-LDD systems and the conventional LDD systems regarding system configurations, component design, energy efficiency, and dehumidification performance characteristics. The main findings from the review include the preferred use of packed bed over membrane-based dehumidifiers, the use of internally cooled dehumidifiers enabled by the HP cooling capacity, the high dispersion of HP operation conditions, and the dependence of dehumidification performance on various dehumidifiers. Finally, an outlook for future research on HP-LDD strategies is presented based on the reviewed works and their limitations.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Explainable discrepancy checker and diagnosis for digital Twin-based supervisory control system

By virtually representing a physical object and process, a digital twin (DT) enables optimal autonomous operations by combining classical and novel frameworks in sensors, state predictions, and multi-input/multi-output systems. A DT’s values depend on how well models estimate quantities of interest and on how uncertainty is handled. Moreover, DTs often combine physics-based and data-driven models with mixed fidelities, where classical uncertainty quantification (UQ) struggles with many sources of uncertainty and real-time constraints. Here, this work presents a UQ-based discrepancy checking and diagnosis tool for a DT-based supervisory control system. The tool is developed using metadata from an automated DT development process to learn correlations between sources of uncertainties and outcomes. During operation, it compares predictions with measurements, attributes discrepancies to dominant sources, and recommends parameter and configuration updates. We verify the workflow on a synthetic temperature-control problem and deploy it on a virtual Thermal Energy Delivery System, reducing mismatch and improving control robustness.

22 - GENERAL STUDIES OF NUCLEAR REACTORS↗

Experimental Investigation of Melting and Solidification Processes of Phase Change Material Heat Exchanger

Rapid development and validation of PCM embedded heat exchangers (PCM-HX) concepts warrant a purpose-built test bench. This paper describes a test facility built for testing various PCM-HX configurations and phase change temperatures that will serve to validate the performance of novel PCM-HX designs. The entire test rig is placed in a temperature-controlled environmental chamber. Inside the PCM-HX containers, up to 48 T-type thermocouples can be spatially distributed on and around the tubes depending on the HX type to capture the phase change process over time. In this paper, a straight tube embedded in PCM having a phase change temperature of 37°C in cylindrical containers is tested. The PCM-HX uses water as an in-tube working fluid. Based on the measured data, the energy balance is analyzed, and its temperature distribution is presented. Here, the maximum deviation between the predicted stored energy and the energy stored calculated from experimental measurements is less than 5%.

36 MATERIALS SCIENCE↗

Exploration of Optimizing FPGA-based Qubit Controller for Experiments on Superconducting Quantum Computing Hardware

This work explores avenues and target areas for optimizing FPGA-based control hardware for experiments conducted on superconducting quantum computing systems and serves as an introduction to some of the current research at the intersection of classical and quantum computing hardware. With the promise of building larger-scale error-corrected quantum computers based on superconducting qubit architecture, innovations to room-temperature control electronics are needed to bring these quantum realizations to fruition. The QICK (Quantum Instrumentation Control Kit) is one leading experimental FPGA-based implementations. However, its integration into other experimental quantum computing architectures, especially those using superconducting radiofrequency (SRF) cavities, is largely unexplored. We identify some key target areas for optimizing control electronics for superconducting qubit architectures and provide some preliminary results to the resolution of a control pulse waveform. With optimizations targeted at 3D superconducting qubit setups, we hope to bring to light some of the requirements in classical computational methodologies to bring out the full potential of this quantum computing architecture, and to convey the excitement of progress in this research.

43 PARTICLE ACCELERATORS↗

Coercivity enhancement in hematite/permalloy heterostructures across the Morin transition

Interfacial effects between antiferromagnetic (AFM) and ferromagnetic (FM) materials have long been a center of magnetism studies. Aside from the exchange bias occurring at the AFM/FM interface, controlling the coercivity is another significant topic in magnetic recordings. The coercivity of FM materials is often determined through varying grain size, alloy composition, density of defects, etc., which is set during material growth and offers limited room for modification after growth. Hematite (α - Fe 2 O 3 ) is an AFM material that undergoes a temperature-controlled spin-flip transition, the so-called Morin transition. This transition gives an extra degree of freedom making hematite an intriguing component to study the exchange coupling when interfaced with an FM material. Here, in this work, changes in the magnetic properties of soft magnetic permalloy (Ni 81 Fe 19 , or Py) thin films grown on hematite were studied across the Morin transition. Surprisingly, these samples showed a remarkable change in coercivity during the Morin transition. We attribute this effect to the magnetic domain mixture of hematite during the Morin transition. Our findings present a novel method of controlling the coercivity of plain ferromagnetic thin films.

Antiferromagnet↗

Heterogeneous oxidation of amorphous organic aerosol surrogates by O 3 , NO 3 , and OH at typical tropospheric temperatures

Typical tropospheric temperatures render possible phase states of amorphous organic aerosol (OA) particles of solid, semisolid, and liquid. This will affect the multiphase oxidation kinetics involving the organic condensed-phase and gaseous oxidants and radicals. To quantify this effect, we determined the reactive uptake coefficients (γ) of O 3 , NO 3 , and OH by substrate films composed of single and binary OA surrogate species under dry conditions for temperatures from 213 to 313 K. A temperature-controlled coated-wall flow reactor coupled to a chemical ionization mass spectrometer was applied to determine γ with consideration of gas diffusion transport limitation and gas flow entrance effects, which can impact heterogeneous reaction kinetics. The phase state of the organic substrates was probed via the poke-flow technique, allowing the estimation of the substrates' glass transition temperatures. γ values for O 3 and OH uptake to a canola oil substrate, NO 3 uptake to a levoglucosan and a levoglucosan / xylitol substrate, and OH uptake to a glucose and glucose / 1,2,6-hexanetriol substrate have been determined as a function of temperature. We observed the greatest changes in γ with temperature for substrates that experienced the largest changes in viscosity as a result of a solid-to-liquid phase transition. Organic substrates that maintain a semisolid or solid phase state and as such a relatively higher viscosity do not display large variations in heterogeneous reactivity. From 213 to 293 K, γ values of O 3 with canola oil, of NO 3 with a levoglucosan / xylitol mixture, and of OH with a glucose / 1,2,6-hexanetriol mixture and canola oil, increase by about a factor of 34, 3, 2, and 5, respectively, due to a solid-to-liquid phase transition of the substrate. These results demonstrate that the surface and bulk lifetime of the OA surrogate species can significantly increase due to the slowed heterogeneous kinetics when OA species are solid or highly viscous in the middle and upper troposphere. This experimental study will further our understanding of the chemical evolution of OA particles with subsequent important consequences for source apportionment, air quality, and climate.

54 ENVIRONMENTAL SCIENCES↗

A new method for operating a continuous flow diffusion chamber to investigate immersion freezing: assessment and performance study

Glaciation in mixed-phase clouds predominately occurs through the immersion freezing mode where ice nucleating particles (INPs) immersed within supercooled droplets induce nucleation of ice. Currently, model representations of this process are a large source of uncertainty in simulating cloud radiative properties, and to constrain these estimates, continuous flow diffusion chamber (CFDC)-style INP devices are commonly used to assess the immersion freezing efficiencies of INPs. In this study, a new approach was explored to operating such an ice chamber that provides maximum activation of particles without droplet breakthrough and correction factor ambiguity to obtain high-quality INP measurements in a manner that has not been demonstrated as possible previously. The conditioning section of the chamber was maintained at ~ –20 °C and water relative humidity (RH w ) ~ 113 % conditions to maximize the droplet activation, and the droplets were supercooled with an independently temperature-controlled nucleation section at a steady cooling rate (0.5 °C min –1 ) to induce the freezing of droplets and evaporation of unfrozen droplets. The performance of the modified ice chamber was evaluated using four INP species: K-feldspar, illite-NX, Argentinian soil dust, and airborne arable dust that had shown ice nucleation over a wide span of supercooled temperatures. Dry dispersed and size-selected K-feldspar particles were generated in the laboratory. Illite-NX and soil dust particles were sampled during the second phase of the Fifth International Ice Nucleation Workshop (FIN-02) campaign, and airborne arable dust particles were sampled from the aerosol inlet located on the rooftop of the laboratory. The measured ice nucleation efficiencies of model aerosols with a surface active site density (n s ) metric were higher, but mostly agreed within one order of magnitude compared to literature results.

54 ENVIRONMENTAL SCIENCES↗

Cylindricity Sensitivity Thermal Model of the AGR-5/6/7 Experiment in the Advanced Test Reactor

The AGR-5/6/7 experiment is currently being irradiated in the Advanced Test Reactor (ATR) at the Idaho National Laboratory and is approximately 70% complete. Several fuel and material irradiation experiments have been planned for the U.S. Department of Energy Advanced Gas Reactor Fuel Development and Qualification Program, which supports the development and qualification of tristructural isotropic (TRISO) coated particle fuel for use in high-temperature gas-cooled reactors. The goals of these experiments are to provide irradiation performance data to support fuel process development, qualify fuel for normal operating conditions, support development of fuel performance models and codes, and provide irradiated fuel and materials for post-irradiation examination and safety testing. Originally planned and named as separate fuel experiments, but subsequently combined into a single test train, AGR-5/6/7 is testing low-enriched uranium oxycarbide TRISO fuel. The AGR-5/6/7 test train has 5 capsules with thermocouples and independent gas control mixtures. Unique to this paper is a sensitivity study concerning the cylindricity of the graphite holders containing the fuel compacts and their eccentricity in relation to the stainless-steel capsule walls. Each capsule has small nubs on the outside used for centering the graphite holder inside the stainless-steel capsule with a small gas gap used to control temperature. Due to machining tolerances of these nubs and vibration wearing the nubs down when the experiment is running in the reactor, the possibility exists that the holder may move around radially. Each capsule is equipped with several thermocouples placed at various radii and depths within each graphite holder. This paper will show the sensitivity of offsetting the graphite holder for various radii in 45-degree increments around the circle with the objective of minimizing the difference between the measured thermocouples and the modeled thermocouple temperatures. Separate gas mixtures of helium/neon are introduced into this gas gap between the holder and capsule wall and changed as necessary to maintain the desired thermocouple temperatures to keep the fuel compacts at constant temperature as the nuclear reactor conditions change. The goal of the sensitivity study is to find a radius and an angle to offset the holder from perfectly centered for each of the five capsules separately. The complex thermal model includes fission heating, gamma heating, radiation heat transfer, and heat transfer via conduction and radiation across the control gaps. Subroutines linked to the thermal model offer an easy method to offset the graphite holder from the capsule walls without remeshing the entire model.