Search NASA⌕ Search

SEARCH · Search NASA

Results for “thermal loading”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 163 records · Page 9

Advanced thermal energy management: A thermal test bed and heat pipe simulation

Work initiated on a common-module thermal test simulation was continued, and a second project on heat pipe simulation was begun. The test bed, constructed from surplus Skylab equipment, was modeled and solved for various thermal load and flow conditions. Low thermal load caused the radiator fluid, Coolanol 25, to thicken due to its temperature avoided by using a regenerator-heat-exchanger. Other possible solutions modeled include a radiator heater and shunting heat from the central thermal bus to the radiator. Also, module air temperature can become excessive with high avionics load. A second preoject concerning advanced heat pipe concepts was initiated. A program was written which calculates fluid physical properties, liquid and vapor pressure in the evaporator and condenser, fluid flow rates, and thermal flux. The program is directed to evaluating newer heat pipe wicks and geometries, especially water in an artery surrounded by six vapor channels. Effects of temperature, groove and slot dimensions, and wick properties are reported.

Barile, Ronald G.↗

Advanced Software for Analysis of High-Speed Rolling-Element Bearings

COBRA-AHS is a package of advanced software for analysis of rigid or flexible shaft systems supported by rolling-element bearings operating at high speeds under complex mechanical and thermal loads. These loads can include centrifugal and thermal loads generated by motions of bearing components. COBRA-AHS offers several improvements over prior commercial bearing-analysis programs: It includes innovative probabilistic fatigue-life-estimating software that provides for computation of three-dimensional stress fields and incorporates stress-based (in contradistinction to prior load-based) mathematical models of fatigue life. It interacts automatically with the ANSYS finite-element code to generate finite-element models for estimating distributions of temperature and temperature-induced changes in dimensions in iterative thermal/dimensional analyses: thus, for example, it can be used to predict changes in clearances and thermal lockup. COBRA-AHS provides an improved graphical user interface that facilitates the iterative cycle of analysis and design by providing analysis results quickly in graphical form, enabling the user to control interactive runs without leaving the program environment, and facilitating transfer of plots and printed results for inclusion in design reports. Additional features include roller-edge stress prediction and influence of shaft and housing distortion on bearing performance.

Poplawski, J. V.↗

Integrated thermal-structural analysis of large space structures

Optimum performance of large space antennas requires very fine control of the shape of the antenna surface since the shape affects both frequency control and pointing accuracy. A significant factor affecting the antenna shape is the temperature of the structure and the resulting deformation. To accurately predict the temperature of the structure, it is necessary first to accurately predict thermal loads. As the structure orbits the Earth, the thermal loads change constantly so that the thermal-structural response varies continuously throughout the orbit. The results from recent applications of integrated finite element methodology to heat load determination and thermal-structural analysis of large space structures are given. Four areas are concentrated on: (1) the characteristics of the integrated finite element methodology, (2) fundamentals of orbital heat load calculation, (3) description and comparison of some radiation finite elements, and (4) application of the integrated finite-element approach to the thermal-structural analysis of an orbiting truss structure.

Mahaney, J.↗

Thermally-driven microfracture in high temperature metal matrix composites

Microfracture (fiber/matrix fracture, interphase debonding and interply delamination) in high temperature metal matrix composites (HTMMC), subjected to thermal loading, is computationally simulated. Both unidirectional and crossply SiC/Ti15 composites are evaluated for microfracture driven by thermal loads, using multicell finite element models. Results indicate that under thermal loads alone, microfracture propagation is not as sensitive as it is under mechanical loads.

Mital, Subodh K.↗

Thermally-driven microfracture in high temperature metal matrix composites

Microfracture (fiber/matrix fracture, interphase debonding and interply delamination) in high temperature metal matrix composites (HTMMC), subjected to thermal loading, is computationally simulated. Both unidirectional and crossply SiC/Ti15 composites are evaluated for microfracture driven by thermal loads, using multicell finite element models. Results indicate that under thermal loads alone, microfracture propagation is not as sensitive as it is under mechanical loads.

Mital, Subodh K.↗

Demand response of loads having thermal reserves

Systems and methods are described herein that improve grid performance by smoothing demand using thermal reserves. The smoothed demand can reduce peak loads as well as the ramp rate of demand that will otherwise require the use of inefficient, expensive generation sources. These improvements are tied to the selective switching on or off electrical loads that are coupled to thermal reserves, effectively using the thermal reserves as an energy storage mechanism. Historical data of past usage can be used to create load model and ensure that effects on customer comfort are minimized while still accomplishing the beneficial effects for the overall grid, which enables grid owners to both reduce their operational cost by avoiding expensive generation and improve system reliability by achieving more predictable power demand.

Ren, Wei↗

Climate Control Load Reduction Strategies for Electric Drive Vehicles in Cold Weather

When operated, the climate control system is the largest auxiliary load on a vehicle. This load has significant impact on fuel economy for conventional and hybrid vehicles, and it drastically reduces the driving range of all electric vehicles (EVs). Heating is even more detrimental to EV range than cooling because no engine waste heat is available. Reducing the thermal loads on the heating, ventilating, and air conditioning system will extend driving range and increase the market penetration of EVs. Researchers at the National Renewable Energy Laboratory have evaluated strategies for vehicle climate control load reduction with special attention toward grid connected electric vehicles. Outdoor vehicle thermal testing and computational modeling were used to assess potential strategies for improved thermal management and to evaluate the effectiveness of thermal load reduction technologies. A human physiology model was also used to evaluate the impact on occupant thermal comfort. Experimental evaluations of zonal heating strategies demonstrated a 5.5% to 28.5% reduction in cabin heating energy over a 20-minute warm-up. Vehicle simulations over various drive cycles show a 6.9% to 18.7% improvement in EV range over baseline heating using the most promising zonal heating strategy investigated. A national-level analysis was conducted to determine the overall national impact. If all vehicles used the best zonal strategy, the range would be improved by 7.1% over the baseline heating range. This is a 33% reduction in the range penalty for heating.

30 DIRECT ENERGY CONVERSION↗

Ductility of a continuous fiber reinforced aluminum matrix composite

The transverse properties of an aluminum alloy metal matrix composite reinforced by continuous alumina fibers have been investigated. The composite is subjected to both mechanical and cyclic thermal loading. The ductility can vary by an order of magnitude according to the operating conditions. For high mechanical and low thermal loading the ductility is small, for low mechanical and high thermal loading the ductility is an order of magnitude higher. Experiments on a beam in bending confirm that the ductility is strongly dependent on the loading conditions. The observations suggest a means of utilizing the inherent ductility of the matrix.

Jansson, S.↗

Mutual Influence of Capillary Pumps in Heat-Pipe Systems with Different Evaporator Loads

Thermal management systems that are not hermetically sealed have been developed for use in spacecraft; in such systems, scientific equipment and instruments operate in open space. Accordingly, new methods of thermal regulation have been developed: axial and loop heat pipes; and honeycomb thermal panels with embedded axial heat pipes. Heat transfer in heating systems with heat pipes is based on evaporation and condensation in a two-phase loop. The working fluid moves under the action mainly of capillary forces that appear in capillary channels or honeycomb structures for axial heat pipes and in the porous heated medium (capillary pump) of the loop heat pipes.

42 ENGINEERING↗

Electromagnetic turbulence simulation of tokamak edge plasma dynamics and divertor heat load during thermal quench

Abstract The edge plasma turbulence and transport dynamics, as well as the divertor power loads during the thermal-quench phase of tokamak disruptions, are numerically investigated with BOUT++’s flux-driven six-field electromagnetic turbulence model. Here, transient yet intense particle and energy sources are applied at the pedestal top to mimic the plasma power drive at the edge induced by a core thermal collapse, which flattens the core temperature profile. Interesting features, such as surging of divertor heat load (up to 50 times) and broadening of heat-flux width (up to four times) on the outer-divertor target plate, are observed in the simulation, in qualitative agreement with experimental observations. The dramatic changes in divertor heat load and width are due to the enhanced plasma turbulence activities inside the separatrix. Two cross-field transport mechanisms, namely, the E × B turbulent convection and the stochastic parallel advection/conduction, are identified to play important roles in this process. First, an elevated edge pressure gradient drives instabilities and subsequent turbulence in the entire pedestal region. The enhanced turbulence not only transports particles and energy radially across the separatrix via the E × B convection, which causes the initial divertor heat-load burst, but it also induces amplified magnetic fluctuation B ˜ . Once themagnetic fluctuation is large enough to break the magnetic flux surface, magnetic flutter effect provides an additional radial transport channel. In the late stage of our simulation, | B ˜ r / B 0 | reaches to 10 −4 level that completely breaks magnetic flux surfaces such that stochastic field lines are directly connecting pedestal top plasma to the divertor target plates or first wall, further contributing to the divertor heat-flux width broadening.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Single Crystal Rhombohedral Epitaxy of Sige on Sapphire at 450.Degree. C.-500.Degree. C. Substrate Temperatures

Various embodiments may provide a low temperature (i.e., less than 850° C.) method of Silicon-Germanium (SiGe) on sapphire (Al2O3) (SiGe/sapphire) growth that may produce a single crystal film with less thermal loading effort to the substrate than conventional high temperature (i.e., temperatures above 850° C.) methods. The various embodiments may alleviate the thermal loading requirement of the substrate, which in conventional high temperature (i.e., temperatures above 850° C.) methods had surface temperatures within the range of 850° C.-900° C. The various embodiments may provide a new thermal loading requirement of the sapphire substrate for growing single crystal SiGe on the sapphire substrate in the range of about 450° C. to about 500° C.

Choi, Sang Hyouk↗

The Combinations of Thermal and Load Stresses for the Onset of Permanent Buckling in Plates

A simple and practical method for evaluating the onset of permanent buckling in plates in the presence of combined thermal and compressive load stresses is outlined. A particular application of the method shows reasonable agreement with tests of 17-7 PH stainless-steel square tubes. The results indicate that the compressive load stress which the plate can support at the onset of permanent buckling is substantially reduced as the temperature difference of the plate and adjoining members increases.

LOADS AND STRESSES, STRUCTURAL - COMPRESSION↗

Continued Development of a Precision Cryogenic Dilatometer for the James Webb Space Telescope

As part of the James Webb Space Telescope (JWST) materials working group, a novel cryogenic dilatometer was designed and built at NASA Jet Propulsion Laboratory to help address stringent coefficient of thermal expansion (CTE) knowledge requirements. Previously reported results and error analysis have estimated a CTE measurement accuracy for ULE of 1.7 ppb/K with a 20K thermal load and 0.1 ppb/K with a 280K thermal load. Presented here is a further discussion of the cryogenic dilatometer system and a description of recent work including system modifications and investigations.

thermal strain↗

Cryogenic thermal modeling of microwave high density signaling

Superconducting quantum computers require microwave control lines running from room temperature to the mixing chamber of a dilution refrigerator. Adding more lines without preliminary thermal modeling to make predictions risks overwhelming the cooling power at each thermal stage. In this paper, we investigate the thermal load of SC-086/50-SCN-CN semi-rigid coaxial cable, which is commonly used for the control and readout lines of a superconducting quantum computer, as we increase the number of lines to a quantum processor. We investigate the makeup of the coaxial cables, verify the materials and dimensions, and experimentally measure the total thermal conductivity of a single cable as a function of the temperature from cryogenic to room temperature values. We also measure the cryogenic DC electrical resistance of the inner conductor as a function of temperature, allowing for the calculation of active thermal loads due to Ohmic heating. Fitting this data produces a numerical thermal conductivity function used to calculate the static heat loads due to thermal transfer within the wires resulting from a temperature gradient. The resistivity data is used to calculate active heat loads, and we use these fits in a cryogenic model of a superconducting quantum processor in a typical Bluefors XLD1000-SL dilution refrigerator, investigating how the thermal load increases with processor sizes ranging from 100 to 225 qubits. We conclude that the theoretical upper limit of the described architecture is approximately 200 qubits. However, including an engineering margin in the cooling power and the available space for microwave readout circuitry at the mixing chamber, the practical limit is approximately 140 qubits.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Carbon-Carbon Recuperators in Closed-Brayton-Cycle Space Power Systems

The use of carbon-carbon (C-C) recuperators in closed-Brayton-cycle space power conversion systems was assessed. Recuperator performance was forecast based on notional thermodynamic cycle state values for planetary missions. Resulting thermal performance, mass and volume for plate-fin C-C recuperators were estimated and quantitatively compared with values for conventional offset-strip-fin metallic designs. Mass savings of 40-55% were projected for C-C recuperators with effectiveness greater than 0.9 and thermal loads from 25-1400 kWt. The smaller thermal loads corresponded with lower mass savings; however, at least 50% savings were forecast for all loads above 300 kWt. System-related material challenges and compatibility issues were also discussed.

Barrett, Michael J.↗

Characterization of Ternary NiTiPd High-Temperature Shape-Memory Alloys under Load-Biased Thermal Cycling

While NiTiPd alloys have been extensively studied for proposed use in high-temperature shape-memory applications, little is known about the shape-memory response of these materials under stress. Consequently, the isobaric thermal cyclic responses of five (Ni,Pd)49.5Ti50.5 alloys with constant stoichiometry and Pd contents ranging from 15 to 46 at. pct were investigated. From these tests, transformation temperatures, transformation strain (which is proportional to work output), and unrecovered strain per cycle (a measure of dimensional instability) were determined as a function of stress for each alloy. It was found that increasing the Pd content over this range resulted in a linear increase in transformation temperature, as expected. At a given stress level, work output decreased while the amount of unrecovered strain produced during each load-biased thermal cycle increased with increasing Pd content, during the initial thermal cycles. However, continued thermal cycling at constant stress resulted in a saturation of the work output and nearly eliminated further unrecovered strain under certain conditions, resulting in stable behavior amenable to many actuator applications.

Bigelow, Glen S.↗

Vertical meteorological patterns and their impact on the energy demand of tall buildings

In accordance with the developing economy and growing population, an increasing number of tall buildings have been constructed over the last 20 years. In 2017, there were 144 new buildings worldwide that were 200 m or greater in height; 50% of these buildings were in China. Due to the vertical gradient impact of meteorological parameters, the energy performance of tall buildings differs from that of general buildings. Few studies exist on vertical meteorological changes using measured data at different heights. Most studies on dynamic energy simulation simulate meteorological parameters using models. This study explores vertical meteorological patterns using hourly dry-bulb temperature, relative humidity, and wind speed data from 2007 to 2017 for a 325 m meteorological tower in Beijing. The temperature decreased significantly with increasing altitude (~0.9 °C per 100 m), while the daily temperature difference decreased with increasing altitude. The absolute humidity did not change significantly with height. The wind speed increased with altitude at approximately 2 m/s per 100 m. The building simulation showed that the annual heating load at a height of 320 m increased by 85% from that at 8 m; the annual cooling load decreased by 20%. Such significant differences in thermal loads for 300-m-tall buildings confirm the need to consider vertical meteorological differences in building performance simulations for tall buildings. A greater number of measurement points at different heights improve the simulation accuracy. Finally, guidance on selecting the heights for vertical metrological measurements is provided based on the influences of building thermal loads.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Fracture mechanics analysis for various fiber/matrix interface loadings

Fiber/matrix (F/M) cracking was analyzed to provide better understanding and guidance in developing F/M interface fracture toughness tests. Two configurations, corresponding to F/M cracking at a broken fiber and at the free edge, were investigated. The effects of mechanical loading, thermal cooldown, and friction were investigated. Each configuration was analyzed for two loadings: longitudinal and normal to the fiber. A nonlinear finite element analysis was performed to model friction and slip at the F/M interface. A new procedure for fitting a square-root singularity to calculated stresses was developed to determine stress intensity factors (K sub I and K sub II) for a bimaterial interface crack. For the case of F/M cracking at a broken fiber with longitudinal loading, crack tip conditions were strongly influenced by interface friction. As a result, an F/M interface toughness test based on this case was not recommended because nonlinear data analysis methods would be required. For the free edge crack configuration, both mechanical and thermal loading caused crack opening, thereby avoiding frictional effects. A F/M interface toughness test based on this configuration would provide data for K(sub I)/K(sub II) ratios of about 0.7 and 1.6 for fiber and radial normal loading, respectively. However, thermal effects must be accounted for in the data analysis.

Naik, R. A.↗