Search NASA⌕ Search

SEARCH · Search NASA

Results for “thermal resistance”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 163 records · Page 9

Performance Assessment of the Overall Building Envelope Thermal Performance—Building Envelope Performance (BEP) Metric

Today, to describe the thermal performance of the building envelope and its components we use a variation of metrics; such as, R-value, ACH (air exchange rate per hour), SHGC (solar heat gain coefficient) of windows, U-factor etc. None of these performance indicators is meant to represent the overall thermal performance. In this paper, such a metric is introduced, the BEP (building envelope performance) value. Unlike the thermal resistance, typically expressed as an R-value, the BEP-value considers additional elements of heat transfer that affect the energy demand of the building because of exterior and interior (solar) thermal loads: conductive and radiant heat transfer, and air infiltration. To demonstrate BEP’s utility, validation studies were carried out by comparing the BEP-value to theoretical results using whole building energy simulation tools such as EnergyPlus and WUFI Plus. Results show that BEP calculations are comparable to calculations made using these simulation tools and that unlike other similar metrics, the BEP-value accounts for all heat transfer mechanisms that are relevant for the overall energy performance of the building envelope. The BEP-value thus allows comparing envelopes of buildings with different use types in a fair and realistic manner.

42 ENGINEERING↗

CAD-based Energy & Cost Models Prove Affordable Net Zero Energy Performance for WonderWindows + 24" On-center Framing

Windows are thermally the “weakest link” in the building envelope. Increasing the thermal resistance of windows can make buildings more energy efficient and reduce the cost of electricity needed for conditioning the building. The proper design and placement of framing can also help to reduce the thermal bridging that occurs near the window frame area. This study investigates the energy performance of multi-pane acrylic windows fitting 24" on-center framing. Initial parametric analysis is done for a single zone accessory dwelling unit (ADU). Then, an energy model was developed for three types of wood-framed buildings: townhomes, stacked flats and hotels. A whole building energy simulation is performed for each of these building types in hot-humid Houston, mixed-humid New York, and cold-humid Minneapolis climates. The results show up to a 39% reduction in heating, ventilation, and air-conditioning (HVAC) related electricity consumption for the cold climate compared to the Base case which has window and wall properties based on ASHRAE standard 90.1 2019. In the hot climate, a modest increase in electricity consumption was seen due to an increase in cooling electricity demand. The ADU achieved Net Zero Energy performance in all 3 Climate Zones despite having the highest exterior surface area-to-floor area ratio: the ADU also had the highest PV kW to floor area ratio compared to the other multi-story building types. The townhomes, hotel and stacked flats respectively met 73, 52 and 57 % of electrical use in Houston, 71, 48 and 56 % in New York, and 63, 40 and 53 % in Minneapolis from energy produced by rooftop solar. If 400 W solar panels are used instead of 320 W panel used for energy simulation, it is estimated that in the townhomes, hotel and stacked flats rooftop solar can meet 91, 65 and 71 % of electrical use in Houston; 89, 60 and 70% in New York, and 79, 50 and 66 % in Minneapolis. A preliminary evaluation of cost shows that such superior performance can potentially be achieved at less first cost with this 24"on-center solution than conventional construction. All the building types at the three locations used for simulation had net energy use intensity under 20 kBtu/sf/year with 320 W solar panel and under 17 kBtu/sf/year with 400 W solar panel. Further tailoring of building envelope R-values and window solar heat gain to particular Climate Zone locations for each building type shows promise in reducing the HVAC electricity use that comprises almost half of building energy use.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Tailorable thermoplastic insulation foam composites enabled by porous-shell hollow glass spheres and expandable thermoplastic microspheres

Here we report a simple and commercially viable strategy to produce thermoplastic composite foams using synergistic foaming approaches – incorporating porous-shell hollow-interior glass spheres (PHGS) as a filler and utilizing expandable thermoplastic microspheres (EMS) as a physical blowing agent – for thermal insulation applications. The EMS in these composites ensure formation of highly porous, low-density foam while the PHGSs provide low thermal conductivity and lightweight mechanical reinforcement. Through systematic optimization of the PHGS and EMS loadings, a lightweight, and robust insulation with thermal resistivity greater than 27.7 m·K/W (R/in. > 4) is achieved. Notably, the fabricated foams also demonstrated comparable compressive strength than some commercial thermoplastic insulating materials. Through optimization of PHGS and EMS concentrations, results indicated similar thermal performance characteristics at varying foam densities, while higher loadings of both components lead to reduced insulation performance and weak mechanical stability of the foams. The results obtained, when coupled with the potential scalability and tailor ability of the overall process towards targeted insulation performance, not only endows competitiveness with current commercial thermoplastic insulating materials but also offers great promise for the development of unique thermoplastic composite foams for a variety of insulation systems.

36 MATERIALS SCIENCE↗

Modelling and Simulation of a Thermoelectric Heat Pump with Micro-Channel Heat Transfer

Thermoelectric heat pumps (TEHPs) have advantages of modularity and simple design for heating and cooling in some applications. Models of thermoelectric (TE) heat pumps are widely studied. Nevertheless, most existing modeling work focuses on the TE material or air-sourced TE modules. TEHP modeling, especially the relationship between modules and heat exchangers, has not been comprehensively conducted. This work presents a water-to-water TEHP modeling framework that combines Goldsmid’s approach for TE material performance, Gnielinski’s correlation for convective heat transfer, and thermal balance theory for heat exchange networks. This combined framework provides an accurate theoretical analysis of the water-to-water TEHP system. Subsequently, the framework was used to empirically determine TE material properties (electric resistivity, thermal conductivity, and Seebeck coefficient) that minimize modeling errors versus experimentally observed values from the literature. Finally, an additional set of experimental TEHP data was used to validate the model, all with relative absolute deviations of approximately 10% when predicting heating capacity and 10%–20% when forecasting cooling capacity at a 30 K temperature lift. For future work, people can further develop models of TEHPs with an air-based heat sink on one side and water channels on the other side.

Wan, Hanlong↗

Summary of Graphite Data Stored within NDMAS

The Graphite Technology Development Project provides data to support the design of graphite core components within specific reactor service conditions of the next generation of high-temperature, gas-cooled nuclear reactors. Physical, mechanical, and thermal properties of nuclear grade graphite were characterized for specimens that were unirradiated, irradiated, and irradiated under various stress conditions. The material properties include diameter, length, mass, density, compressive strength, tensile strength, flexural strength, modulus, resistivity, thermal diffusivity, and thermal expansion coefficient. Baseline graphite specimens are unirradiated from different grades (2114, IG-110, NBG-17, NBG-18, and PCEA) and different types used in different characterization tests (compressive, flexural, tensile, one-inch cylinder, and quarter-inch cylinder). The Advanced Graphite Creep (AGC) irradiation specimens are from a much larger number of grades and cylinder types (creep, piggyback, and pencil). For baseline graphite, characterization data for 7,756 specimens extracted from thirteen graphite billets were captured to the NDMAS database. For AGC experiments, four irradiation campaigns have been completed: AGC-1, AGC-2, AGC-3, and AGC-4. The ongoing HDG-1 (High-Dose Graphite) experiment, which began irradiation with Cycle 168B on August 26, 2020, includes specimens previously irradiated in AGC-2 in addition to the specimens originally destined for AGC-5.. Besides the characterization data, the AGC data includes irradiation monitoring and physics data representing the irradiation conditions of AGC specimens. Currently, all data for AGC-1, AGC-2, and AGC-3 have been captured to the NDMAS database. Only AGC-4 pre-irradiation and irradiation monitoring data have been captured, and HDG-1 pre-irradiation data are in process of being captured for unirradiated specimens. To date, a total of 38,149 material property records have been captured into NDMAS database for baseline and AGC specimens. All characterization data are qualified for use according to their perspective data verification reports. For the AGC irradiation campaigns, a total of 41,502 qualified physics calculation records were added for AGC-1, AGC-2, and AGC-3. Finally, a total of 173,698,505 AGC irradiation monitoring data records (thermocouple temperature, gas flow rate, gas pressure, gas moisture, applied load, and specimen displacement) have been captured to NDMAS; the majority of those records (~94%) are qualified data records.

11 - NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

Fast and accurate machine learning prediction of phonon scattering rates and lattice thermal conductivity

Abstract Lattice thermal conductivity is important for many applications, but experimental measurements or first principles calculations including three-phonon and four-phonon scattering are expensive or even unaffordable. Machine learning approaches that can achieve similar accuracy have been a long-standing open question. Despite recent progress, machine learning models using structural information as descriptors fall short of experimental or first principles accuracy. This study presents a machine learning approach that predicts phonon scattering rates and thermal conductivity with experimental and first principles accuracy. The success of our approach is enabled by mitigating computational challenges associated with the high skewness of phonon scattering rates and their complex contributions to the total thermal resistance. Transfer learning between different orders of phonon scattering can further improve the model performance. Our surrogates offer up to two orders of magnitude acceleration compared to first principles calculations and would enable large-scale thermal transport informatics.

36 MATERIALS SCIENCE↗

A Novel Steam Condenser with Loop Thermosyphons and Film-Forming Agents for Improved Heat Transfer Efficiency and Durability

In this DOE/NETL BAA program, Advanced Cooling Technologies, Inc. (ACT), with Suez Water Technologies & Solutions (Suez), developed film-forming amine coatings applied to condenser surfaces that incorporated loop thermosyphons to enhance steam surface condenser performance and efficiency for coal-fired power plants. The condensation phenomenon resulting from these coatings promotes efficient dropwise condensation without additional thermal resistance through the use of film-forming amines (FFA). The loop thermosyphon technology was being developed to supplant current pumped cooling water systems to reduce operations and maintenance issues, reduce energy use, and promote high thermal performance. Both of ACT’s advanced coating and loop thermosyphon technologies were developed for application to wet cooling and indirect dry cooling systems. Internal steam condensation and subsequent heat dissipation complete the thermodynamic power cycle used by power plant cooling systems. The successful 3-year project period delved into understanding the experimental performance gain using film-forming amines applied to flat and tubular condenser surfaces under realistic operating conditions. The performance gain was used to create a technoeconomic analysis to more clearly understand the market value for power plants using FFA coatings to achieve dropwise condensation on condenser surfaces. A tall (50 ft.) loop thermosyphon was designed, fabricated, and tested to optimize the performance characteristics by tuning the working fluid charge and determining the temperature drop across the loop at different heat loads. Commercialization opportunities were explored to transition the loop thermosyphon work into the building HVAC market.

20 FOSSIL-FUELED POWER PLANTS↗

Molecular aspect ratio effect on axial thermal transport in solution-spun carbon nanotube fibers

Neat, densely packed, and highly aligned carbon nanotube fibers (CNTFs) have appealing room-temperature axial thermal conductivity (⁠k⁠) and thermal diffusivity (⁠α⁠) for applications in lightweight heat spreading, flexible thermal connections, and thermoelectric active cooling. Although CNTFs are regularly produced from different input carbon nanotubes (CNTs), prior work has not quantified how the CNT molecular aspect ratio r (i.e., molecular length-to-diameter ratio) influences k and in well-aligned, packed CNTFs. Here, we perform self-heated steady-state and three-omega thermal measurements at room temperature on CNTF suspended in vacuum. Our results show that k increases from 150 to 380 W / mK for viscosity-averaged molecular aspect ratios increasing from r = 960 to 5600 and nanotube diameters of ~2 nm, which we attribute to the effects of thermal resistances between CNT bundles. CNTFs made with varying volume fraction Φ of constituent high-r and low-r CNT have properties that fall within or below the typical macroscopic rule-of-mixtures bounds. The thermal diffusivity α scales with k, leading to a sample-averaged volumetric heat capacity of 1.5 ± 0.3 MJ / m 3 K⁠. This work's findings that fibers made from longer CNT have larger k and α at room temperature motivate further investigation into thermal transport in solution-spun CNTF.

42 ENGINEERING↗

Characterization of Highly Thermally Conductive Organic Substrates for a Double-Sided Cooled Power Module

Abstract Silicon-Carbide (SiC) power devices have become a promising option for traditional Silicon (Si) due to the superior material properties. To fully take advantage of the SiC devices, a high-performance power device packaging solution is necessary. This study proposes a cost-effective double-sided cooled (DSC) 1.2 kV SiC half-bridge power module using organic epoxy-resin composite dielectric (ERCD) substrates. The high mechanical and thermal performance of the power module is achieved by the low-modulus, moderate thermal conductivity, and relatively thin (120 μm) layer of ERCD material compared with traditional metal-clad ceramic approaches. This novel organic dielectric can withstand high voltage (5 kV @ 120 μm) and operate up to 250°C continuously, which is indispensable for high power applications. The thermal modeling results show that the equivalent thermal resistance junction-to-case (Rjc_eq) of the DSC power module using dual direct bonded copper (DBC) is 17% higher than the dual ERCD configuration. Furthermore, a non-insulated DSC power module concept is proposed for maximizing thermal performance by considering thermal vias in the ERCD substrate and direct-soldered heat sink. A thought process for optimization of thermal via design is demonstrated and it shows up to 24% of improvement on thermal performance compared with the insulated DSC power module.

Double-sided cooling, epoxy-resin composite dielec↗

Critical roles of pores and moisture in sustainable nanocellulose-based super-thermal insulators

In a recent report in Matter, Bergström and co-workers describe a novel thermal transport behavior that subverts this assumption of porous materials. In their work, the authors describe a nanocellulose-based foam that features ultrahigh porosity (> 99.6%) and aligned µm-scale pores (10–100 µm) whose radial thermal conductivity (i.e., perpendicular to the pore alignment) is close to that of free air in the dry state. Furthermore, the radial thermal conductivity of the cellulose-based foam can be reduced to ~14 mW/(m·K) when the relative humidity is ~35%. Super-thermal insulators, which demonstrate a thermal conductivity below that of stationary air (~ 25 mW/(m·K), 20 ºC, 1.0 atm), are needed to minimize heat loss in various applications (e.g., buildings, thermal energy storage tanks, cold chain packaging, etc.) to mitigate the energy crisis and reduce carbon emissions. Introducing pores into a material is a facile and effective way to achieve low thermal conductivity as pores can suppress thermal transport through solids by reducing the cross-sectional area and increasing the tortuosity of the heat transfer pathway. In porous structures there are two kinds of pores: open and closed. While increased porosity can reduce heat conduction through solids with an open porous structure, the improved gas conduction creates a competing effect that simultaneously elevates the heat transfer. Therefore, the thermal conductivity of a material with µm-scale open pores is usually larger than that of stationary air. Reducing the pore size to less than the mean free path of air (~ 70 nm, 20 ºC, 1.0 atm) can effectively reduce gas conduction, enabling the material to achieve a thermal conductivity below that of stationary air. However, high cost of the nanosized raw materials and time-consuming fabrication processes limit the large-scale applications of nanoporous thermal insulators. Meanwhile, closed pores can block heat transport only through the continuous gas phase. As a result, the thermal conductivity of a closed porous structure can theoretically be much smaller than that of stationary air if the solid conduction can also be suppressed by (1) lowering the solid content of the material, (2) reducing the thermal conductivity of the building blocks of the material, and/or (3) increasing interfacial thermal resistance between neighboring building blocks. Most processes used to generate porous structures (e.g., supercritical drying, freeze drying) involve a solvent that escapes the material. Therefore, it is difficult to create pores and isolate them simultaneously, preventing the fabrication of super-thermal insulators with closed pores.

36 MATERIALS SCIENCE↗

Thermal conductivity evaluation of ion irradiated Si 3 N 4 and ZrN ceramics using spatial domain thermoreflectance

Nitride ceramics have been investigated for different applications in the nuclear industry, such as space nuclear power, fusion reactor diagnostics and plasma heating, inert matrix fuels, and accident tolerant fuels. Although thermal conductivity remains one of the most important properties to track following irradiation, traditional techniques such as laser flash and xenon flash are limited to bulk sample characterization, which requires lengthy and cost-consuming neutron irradiation. This work used spatial domain thermoreflectance (SDTR) for the micrometer-scale measurement of thermal conductivity in 15 MeV Ni ion-irradiated silicon nitride and zirconium nitride from 1 to 50 dpa and 300 to 700 °C. Here, the SDTR-measured unirradiated thermal conductivity was found to be consistent with the published data on bulk samples. Electrically conductive ZrN exhibits modest reduction after irradiation which is minimal at the highest irradiation temperatures. In electrically insulating Si 3 N 4 , the reduction is more significant and unlike ZrN, the reduction remains significant even at a higher irradiation temperature. The thermal resistance evolution following irradiation was compared with lattice swelling, which was determined using grazing incidence x-ray diffraction, and radiation-induced defects were observed using transmission electron microscopy. A saturation value was observed between 15 and 50 dpa for thermal conductivity degradation in both nitride ceramics and a direct correlation with high-temperature defect recombination was observed, as well as the potential presence of additional carrier scattering mechanisms.

36 MATERIALS SCIENCE↗

Clinkerless ultra-high strength concrete based on alkali-activated slag at high temperatures

This work investigates the degradation mechanisms of clinkerless alkali-activated slag based ultra-high strength concrete (AAS-UHSC) upon exposure to high temperatures up to 800 °C. The heat-induced mechanical, mineralogical, molecular, microstructural, and pore structure alterations of AAS-UHSC prepared with various activator types, water-to-powder ratios, and fiber incorporation are studied. The results demonstrate the beneficial roles of potassium incorporation on improving the thermal stability and integrity of AAS-UHSC, via suppressing deleterious crystallization and transformation of aluminosilicate phases at high temperature. In contrast to Portland cement clinker-based UHSC, no sign of explosive spalling is observed in AAS-UHSC, likely due to the presence of microcracks that enhance the pore network connectivity. The mechanical degradation of AAS-UHSC at high temperature below 600 °C is resulted from dehydration and decomposition of phases and consecutive thermal cracking, together with enlarged porosity and coarsened pore structure. As the temperature rising to 800 °C, crystallization and transformation of phases, as well as formation of porous microstructure, considerably aggravate the mechanical degradation of AAS-UHSC. In contrast to the thermal damage mitigation by polymeric fibers in conventional UHSC, the fiber incorporation has little positive impact on the thermal resistance of AAS-UHSC.

36 MATERIALS SCIENCE↗

Pre-Bleaching Coral Microbiome Is Enriched in Beneficial Taxa and Functions

Coral reef health is tightly connected to the coral holobiont, which is the association between the coral animal and a diverse microbiome functioning as a unit. The coral holobiont depends on key services such as nitrogen and sulfur cycling mediated by the associated bacteria. However, these microbial services may be impaired in response to environmental changes, such as thermal stress. A perturbed microbiome may lead to coral bleaching and disease outbreaks, which have caused an unprecedented loss in coral cover worldwide, particularly correlated to a warming ocean. The response mechanisms of the coral holobiont under high temperatures are not completely understood, but the associated microbial community is a potential source of acquired heat-tolerance. Here we investigate the effects of increased temperature on the taxonomic and functional profiles of coral surface mucous layer (SML) microbiomes in relationship to coral–algal physiology. We used shotgun metagenomics in an experimental setting to understand the dynamics of microbial taxa and genes in the SML microbiome of the coral Pseudodiploria strigosa under heat treatment. The metagenomes of corals exposed to heat showed high similarity at the level of bacterial genera and functional genes related to nitrogen and sulfur metabolism and stress response. The coral SML microbiome responded to heat with an increase in the relative abundance of taxa with probiotic potential, and functional genes for nitrogen and sulfur acquisition. Coral–algal physiology significantly explained the variation in the microbiome at taxonomic and functional levels. These consistent and specific microbial taxa and gene functions that significantly increased in proportional abundance in corals exposed to heat are potentially beneficial to coral health and thermal resistance.

59 BASIC BIOLOGICAL SCIENCES↗

Validation of MFUEL Metal Fuel Performance Models of SAS4A/SASSYS-1

The fuel characterization models of SAS4A/SASSYS-1 (SAS) have recently been extended to include a new U-Pu-Zr metal fuel model, MFUEL. MFUEL is equipped with mechanistic physics based models to predict the pre-transient characterization and transient response of metal fuel, with emphasis on fuel melting, cladding failure, and the metal fuel’s impact on core reactivity. The MFUEL model will be available in the full version of SAS4A/SASSYS-1 5.7, which is scheduled to be released in June 2023. Fast reactor fuel pins that operated in EBR-II and FFTF with low smear density U-Zr and U-Pu-Zr metal fuels and irradiation resistant ferritic-martensitic cladding showed significant advantages in achieving high burnups and assuring inherent safety characteristics during anticipated transients, design basis events, and beyond design basis events. For safety analysis, a fuel performance model must be able to predict (1) Fuel pin mechanics and compositional and dimensional changes, (2) Clad failure, and (3) Fuel pin thermal resistance. Achieving these high level goals accurately is strongly related to the model performance of individual physical processes taking place within a fuel pin during its lifetime. Metal fuels typically operate above the mid-point temperature of melting during normal, as well as off-normal, conditions. At these elevated temperatures, the availability of thermal activation provides a driving force for various diffusional processes leading to complex phase transformations, micro-structure evolution, significant amounts of fuel swelling, interconnected porosity formation, excessive amounts of fission gas release, and fuel clad chemical interactions. Clad failure in fast reactors primarily occurs as a result of creep rupture augmented by clad wastage formation. The reaction is driven by thermal creep induced dislocation motion, grain boundary cavity nucleation, growth and breakup of grain boundaries. The high level complexity and limited available data requires introducing physics-based modeling approaches to gain extrapolation ability and sensitivity with respect to various conditions. The objective of this report is to perform validation of MFUEL using the experimental data for (1) Normal operation EBR-II fuel behavior, (2) Normal operation PHENIX fuel behavior, (3) HT9 Pressure tube ramp-and-hold creep rupture tests, (4) Whole Pin Furnace (WPF) creep strain, creep rupture and eutectic tests, (5) Fuel Behavior Test Apparatus (FBTA) eutectic tests, and (6) TREAT M5-7 OverPower tests up to clad failure. Section-2 includes a brief description of the MFUEL models. A detailed description of the MFUEL physics-based, semi-empirical models will be presented in the SAS V 5.7 theory manual. Section-3, 4, and 5 describes the validation effort for the pre-transient irradiation, furnace transients, and TREAT M-Series transients, respectively.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

A thermodynamic model of integrated liquid-to-liquid thermoelectric heat pump systems

Thermoelectric (TE) heat pumps (TEHPs) are advantageous for heating and cooling in various applications because of their modularity and simple design. A TEHP system includes the TE modules with p- and n-type materials bonded to substrates, plus heat exchangers, thermal interfaces to the heat exchangers, and heat transfer fluids. Although modeling an individual TE module has been extensively studied, limited studies have reported performance at the larger system-level. Furthermore, no prior study has addressed the impact of temperature-dependent TE material properties (e.g., electric resistivity, thermal conductivity, and Seebeck coefficient) on overall heat-pump-system-level performance. Here, this work presents a mathematical model for TEHP system performance based on Goldsmid's approach for TE material performance, “effective” TE material properties, Gnielinski's correlation for convective heat transfer, and thermal balance theory for a heat exchange network. This combined approach provides an accurate model of the liquid-to-liquid TEHP system. Three different approaches—one empirical, one based on the manufacturer's specifications, and one drawn from the literature—were then used to determine values for TE material properties. The first two methods treated properties as constants, while the last approach treated properties as surface-temperature-based functions. Finally, experimental TEHP data was used to validate the models, all with relative absolute deviations of approximately 10% when predicting heating capacity and 10%–25% when forecasting cooling capacity up to a 30 K surface temperature lift. The results demonstrated that, at the TEHP system level, the TE material properties could be treated as constants, avoiding solver iterations and reducing the performance uncertainty by up to 95%.

42 ENGINEERING↗

Automotive Power Electronics Cooling Technology Research at NREL

This presentation describes power electronics thermal management technologies used for on-road EVs. Examples are provided and heat exchangers are described. Advanced cooling technologies developed are NREL to enable increased power density and enable high WBG temperature operation are then presented. The performance (e.g., thermal resistance, pumping power) of the advanced power electronics cooling technologies are compared to the performance of current, on-road technology.

ADVANCED PROPULSION SYSTEMS↗

Power Electronics Cooling Technology Research at NREL

This presentation describes power electronics thermal management technologies used for on-road EVs. Examples are provided and heat exchangers are described. Advanced cooling technologies developed are NREL to enable increased power density and enable high WBG temperature operation are then presented. The performance (e.g., thermal resistance, pumping power) of the advanced power electronics cooling technologies are compared to the performance of current, on-road technology.

DIRECT ENERGY CONVERSION↗

Design and evaluation of a dilute flow particle-to-air heat exchanger for energy storage applications

The use of inert and redox-active particles for high-temperature energy storage requires the development of components that can efficiently transfer energy to high-pressure working fluids like supercritical carbon dioxide (sCO 2 ). Dilute flow reactors can enable high working fluid outlet temperatures and minimal parasitic losses compared to moving packed bed and fluidized bed reactors. This research uses both computational and experimental methods to explore the design trade-offs and practical challenges of a novel component for transferring energy from dilute flows of hot, reduced metal oxide (MO x ) particles to sCO 2 in tubes. A discretized thermal resistance network model, which accounts for particle hydrodynamics, multi-mode heat transfer, and reaction equilibrium, guides the design of a prototype device. This device is experimentally tested with a surrogate heat transfer fluids and inert particle temperatures up to 400°C and a heat duty exceeding 1 kW. The data are used to validate the thermal hydraulic sub-models, allowing for the simulation of reacting particle scenarios. Under nominal design conditions, the flow rate of reactive particles is predicted to be 30% lower than that of inert particles for the same energy recovered, with over 70% of the stored particle energy transferred to the sCO 2 . Furthermore, these findings can inform the design of more efficient energy recovery reactors for particle-based systems and can be integrated into system-level concentrated solar power models with thermal storage to optimize operating conditions.

14 SOLAR ENERGY↗