Search NASA⌕ Search

SEARCH · Search NASA

Results for “total dose”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 163 records · Page 9

AD620SQ/883B Total Ionizing Dose Radiation Lot Acceptance Report for RESTORE-LEO

A Radiation Lot Acceptance Test was performed on the AD620SQ/883B, Lot 1708D, in accordance with MIL-STD-883, Method 1019, Condition D. Using a Co-60 source 4 biased parts and 4 unbiased parts were irradiated at 10 mrad/s (0.036 krad/hr) in intervals of approximately 1 krad from 3-10 krads, and ones of 5 krads from 10-25 krads, where it was annealed while unbiased at 25 degrees Celsius, for 2 days, and then, subsequently, annealed while biased at 25 degrees celsius, for another 7 days.

Bipolar↗

STRV RADMON: An integrated high-energy particle detector

The RADMON (Radiation Monitor) was developed as a compact device with a 4-kbit SRAM particle detector and two p-FET total dose monitors. Thus it can be used as a spacecraft radiation alarm and in situ total dose monitor. This paper discusses the design and calibration of the SRAM for proton, alpha, and heavy ion detection. Upset rates for the RADMON, based on a newly developed space particle flux algorithm, are shown to vary over eight orders of magnitude. On the STRV (Space Technology Research Vehicle) the RADMON's SRAM will be used to detect trapped protons, solar flares, and cosmic rays and to evaluate our ability to predict space results from ground tests.

Buehler, Martin↗

STRV RADMON: An Integrated High-Energy Particle Detector

The RADMON (Radiation Monitor) was developed as a compact device with a 4-kbit SRAM particle detector and two p-FET total dose monitors. Thus it can be used as a spacecraft radiation alarm and in situ total dose monitor. This paper discusses the design and calibration of the SRAM for proton, alpha, and heavy ion detection. Upset rates for the RADMON, based on a newly developed space particle flux algorithm, are shown to vary over eight orders of magnitude.

RADMON↗

The X-Irradiation of Hydrazine and 1,1- Dimethylhydrazine

Hydrazine and 1,1-dimethylhydrazine were radiolyzed at room temperature by using about 1 gram of liquid or 1/2 to 2 liters of vapor at room-temperature vapor pressure. A tungsten-target X-ray source operating at 300 kilovolts and 6 to 8 milliamperes (0.1 to 1.0 A) was used at intensities of 1 times 10 (sup 2) to 1 times 10 (sup 3) roentgens per minute to give total doses of 4.1 rads to 2.3 times 10 (sup 6) rads. The amounts of decomposition were dependent on total dose and independent of dose rate. In the case of hydrazine vapor, the decomposition was also directly related to surface area. There was a lesser surface effect with liquid hydrazine, but this variable was not studied for 1,1-dimethylhydrazine. The order of decreasing sensitivity to X-radiation is as follows: hydrazine vapor, 1,1-dimethylhydrazine vapor, 1,1-dimethylhydrazine liquid, and hydrazine liquid. The decomposition products of hydrazine were nitrogen, hydrogen, ammonia, and unidentified products. The same products plus methylamine, dimethylamine, and hydrazine were found from the decomposition of 1,1-dimethylhydrazine. In addition, the 1,1-dimethylhydrazine underwent post-irradiation changes. Values for G (number of molecules of sample decomposed per 100 electronvolts of absorbed energy) of the order of 10 (sup 6) suggest that the vapor-phase decompositions are chain reactions.

X-RAY IRRADIATION↗

Summary of Proton Test on the Quick Logic QL3025 at Indiana University

This issue of the Programmable Logic Application Notes is a compilation of topics: (1) Proton irradiation tests were performed on the Quick Logic QL3025 at the Indian University Cyclotron facility. The devices, tests, and results are discussed; (2) The functional failure of EEPROM's in heavy ion environment is presented; (3) the Act 1 architecture is summarized; (4) Antifuse hardness and hardness testing is updated; the single even upset (SEU) response of hardwired flip-flops is also presented; (4) Total dose results of the ACT 2 and ACT 3 circuits is presented in a chart; (5) Recent sub-micron devices testing of total dose is presented in a chart along with brief discussion; and (6) a reference to the WWW site for more articles of interest.

Katz, Richard↗

Dose and dose rate effects of whole-body gamma-irradiation: II. Hematological variables and cytokines

The goal of part II of this study was to evaluate the effects of gamma-radiation on circulating blood cells, functional characteristics of splenocytes, and cytokine expression after whole-body irradiation at varying total doses and at low- and high-dose-rates (LDR, HDR). Young adult C57BL/6 mice (n = 75) were irradiated with either 1 cGy/min or 80 cGy/min photons from a 60Co source to cumulative doses of 0.5, 1.5, and 3.0 Gy. The animals were euthanized at 4 days post-exposure for in vitro assays. Significant dose- (but not dose-rate-) dependent decreases were observed in erythrocyte and blood leukocyte counts, hemoglobin, hematocrit, lipopolysaccharide (LPS)-induced 3H-thymidine incorporation, and interleukin-2 (IL-2) secretion by activated spleen cells when compared to sham-irradiated controls (p < 0.05). Basal proliferation of leukocytes in the blood and spleen increased significantly with increasing dose (p < 0.05). Significant dose rate effects were observed only in thrombocyte counts. Plasma levels of transforming growth factor-beta 1 (TGF-beta 1) and splenocyte secretion of tumor necrosis factor-alpha (TNF-alpha) were not affected by either the dose or dose rate of radiation. The data demonstrate that the responses of blood and spleen were largely dependent upon the total dose of radiation employed and that an 80-fold difference in the dose rate was not a significant factor in the great majority of measurements.

NASA Discipline Radiation Health↗

Interaction of space radiation with matter

The physical interactions of high-energy space radiations with bulk matter are described with particular emphasis on the nuclear and electromagnetic interactions of solar and galactic cosmic rays. Methods of incorporating these interactions into radiation transport models which accurately describe the propagation of the incident cosmic rays and their subsequent-generation reaction products are also explained. Representative results for solar and galactic cosmic ray doses and dose equivalents are presented for various aluminum and water absorber depths. For the first time, the main contributions to human exposure in space from galactic cosmic rays will be presented on a component by component basis, including a breakdown of the dose-equivalent contributions into primary ions, heavy fragments, alpha particles, neutrons, and protons. For the galactic cosmic ray environment outside of the earth's magnetosphere, over 70 percent of the total dose equivalent results from only seven nuclear species (hydrogen, helium, carbon, oxygen, silicon, magnesium, and iron ions). Of these, the largest single contributor is cosmic ray iron and its secondaries, which account for nearly one-fourth of the unshielded total dose equivalent during solar minimum.

Townsend, L. W.↗

Dose and dose rate effects of whole-body proton irradiation on leukocyte populations and lymphoid organs: part I

The goal of part I of this study was to evaluate the effects of whole-body proton irradiation on lymphoid organs and specific leukocyte populations. C57BL/6 mice were exposed to the entry region of the proton Bragg curve to total doses of 0.5 gray (Gy), 1.5 Gy, and 3.0 Gy, each delivered at a low dose rate (LDR) of 1 cGy/min and high dose rate (HDR) of 80 cGy/min. Non-irradiated and 3 Gy HDR gamma-irradiated groups were included as controls. At 4 days post-irradiation, highly significant radiation dose-dependent reductions were observed in the mass of both lymphoid organs and the numbers of leukocytes and T (CD3(+)), T helper (CD3(+)/CD4(+)), T cytotoxic (CD3(+)/CD8(+)), and B (CD19(+)) cells in both blood and spleen. A less pronounced dose effect was noted for natural killer (NK1.1(+) NK) cells in spleen. Monocyte, but not granulocyte, counts in blood were highly dose-dependent. The numbers for each population generally tended to be lower with HDR than with LDR radiation; a significant dose rate effect was found in the percentages of T and B cells, monocytes, and granulocytes and in CD4(+):CD8(+) ratios. These data indicate that mononuclear cell response to the entry region of the proton Bragg curve is highly dependent upon the total dose and that dose rate effects are evident with some cell types. Results from gamma- and proton-irradiated groups (both at 3 Gy HDR) were similar, although proton-irradiation gave consistently lower values in some measurements.

Non-NASA Center↗

Design and qualification of the SEU/TD Radiation Monitor chip

This report describes the design, fabrication, and testing of the Single-Event Upset/Total Dose (SEU/TD) Radiation Monitor chip. The Radiation Monitor is scheduled to fly on the Mid-Course Space Experiment Satellite (MSX). The Radiation Monitor chip consists of a custom-designed 4-bit SRAM for heavy ion detection and three MOSFET's for monitoring total dose. In addition the Radiation Monitor chip was tested along with three diagnostic chips: the processor monitor and the reliability and fault chips. These chips revealed the quality of the CMOS fabrication process. The SEU/TD Radiation Monitor chip had an initial functional yield of 94.6 percent. Forty-three (43) SEU SRAM's and 14 Total Dose MOSFET's passed the hermeticity and final electrical tests and were delivered to LL.

Buehler, Martin G.↗

Effects of 1-MeV gamma radiation on a multi-anode microchannel array detector tube

A multianode microchannel array (MAMA) detector tube without a photocathode was exposed to a total dose of 1,000,000 rads of 1-MeV gamma radiation from a Co-60 source. The high-voltage characteristic of the microchannel array plate, average dark count, gain, and resolution of pulse height distribution characteristics showed no degradation after this total dose. In fact, the degassing of the microchannels induced by the high radiation flux had the effect of cleaning up the array plate and improving its characteristics.

Timothy, J. G.↗

Radiation Tests of Single Photon Avalanche Diode for Space Applications

Single photon avalanche diodes (SPADs) have been recently studied as photodetectors for applications in space missions. In this presentation we report the results of radiation hardness test on large area SPAD (actual results refer to SPADs having 500 micron diameter). Dark counts rate as low as few kHz at −10 degC has been obtained for the 500 micron devices, before irradiation. We performed bulk damage and total dose radiation tests with protons and gamma-rays in order to evaluate their radiation hardness properties and their suitability for application in a Low Earth Orbit (LEO) space mission. With this aim SPAD devices have been irradiated using up to 20 krad total dose with gamma-rays and 5 krad with protons. The test performed show that large area SPADs are very sensitive to proton doses as low as 2×10(exp 8) (1 MeV eq) n/cm2 with a significant increase in dark counts rate (DCR) as well as in the manifestation of the "random telegraph signal" effect. Annealing studies at room temperature (RT) and at 80 degC have been carried out, showing a high decrease of DCR after 24-48 h at RT. Lower protons doses in the range 1-10×10(exp 7) (1 MeV eq) n/cm(exp 2) result in a lower increase of DCR suggesting that the large-area SPADs tested in this study are well suitable for application in low-inclination LEO, particularly useful for gamma-ray astrophysics.

radiation hardness↗

Space Radiation Effects and Reliability Consideration for the Proposed Jupiter Europa Orbiter

The proposed Jupiter Europa Orbiter (JEO) mission to explore the Jovian moon Europa poses a number of challenges. The spacecraft must operate for about seven years during the transit time to the vicinity of Jupiter, and then endure unusually high radiation levels during exploration and orbiting phases. The ability to withstand usually high total dose levels is critical for the mission, along with meeting the high reliability standards for flagship NASA missions. Reliability of new microelectronic components must be sufficiently understood to meet overall mission requirements.The proposed Jupiter Europa Orbiter (JEO) mission to explore the Jovian moon Europa poses a number of challenges. The spacecraft must operate for about seven years during the transit time to the vicinity of Jupiter, and then endure unusually high radiation levels during exploration and orbiting phases. The ability to withstand usually high total dose levels is critical for the mission, along with meeting the high reliability standards for flagship NASA missions. Reliability of new microelectronic components must be sufficiently understood to meet overall mission requirements.

semiconductor devices↗

Single-Event Gate Rupture and Single-Event Burnout Test Results Performed on Hi-Rel Fuji Power MOSFETs: 2SK4217, 2SK4152, 2SK4155, and 2SK4158

Several newly available Hi-Rel total dose hardened power MOSFETs manufactured by Fuji Electric Device Technology Co. Ltd (FDT) in conjunction with the Japan Aerospace Exploration Agency (JAXA) were tested for single-event gate rupture (SEGR) and single-event burnout (SEB). The safe-operating area (SOA) of the 2SK4217 (a 100 V rated device), 2SK4152 (130 V), 2SK4155 (200 V), and the 2SK4158 (250 V) were tested with silver (Ag) and xenon (Xe) ions having incident LETs of 42.2 and 53.1 MeV cm2/mg, respectively. Test results show these devices are comparable to currently available total dose hardened technology.

Selva, Luis E.↗

The effect of electron irradiation on YBa2Cu3O(x) with gold bead contacts

The effect of 1-MeV electron irradiation, up to a total dose of 5.7 x 10 to the 17th electrons/sq cm at room temperature on YBa2Cu3O(x) was investigated using gold bead contacts made by the melting technique. The superconducting transition temperature Tc, the critical current density Jc at 77 K, the normal-state resistivity, and the contact resistance for gold bead contacts were measured as a function of fluence on the same samples without disturbing the contacts. Tc remained constant at 91 K, and Jc at 77 K remained constant around 90 A/sq cm. The normal-state resistivity increased systematically by about 15 percent for the total dose. Finally, the surface contact resistance at 77 K remained less than 4.2 microohm sq cm throughout the radiations. These studies took place over an 8-month period, and subsequent measurements indicate that the results are definitely due to radiation effects and not aging effects. It is concluded that the superconductor YBa2Cu3O(x) with gold bead contacts would perform well in a space environment of electron irradiation.

Caton, R.↗

Low-dose total-body-calcium analysis

Report details technique for measuring total body calcium by collecting exhaled 37Ar gas after exposure of patients to 14-MeV neutrons. Summary for theoretical basis of technique is presented.

Lewellen, T. K.↗

Total Ionizing Dose Effects in MOS Oxides and Devices

The development of military and space electronics technology has traditionally been heavily influenced by the commercial semiconductor industry. The development of MOS technology, and particularly CMOS technology, as dominant commercial technologies has occurred entirely within the lifetime of the NSREC. For this reason, it is not surprising that the study of radiation interactions with MOS materials, devices and circuits has been a major theme of this conference for most of its history. The basic radiation problem in a MOS transistor is illustrated. The application of an appropriate gate voltage causes a conducting channel to form between the source and drain, so that current flows when the device is turned on. In Fig. lb, the effect of ionizing radiation is illustrated. Radiation-induced trapped charge has built up in the gate oxide, which causes a shift in the threshold voltage (that is, a change in the voltage which must be applied to turn the device on). If this shift is large enough, the device cannot be turned off, even at zero volts applied, and the device is said to have failed by going depletion mode.

Oldham, Timothy R.↗

Total Ionizing Dose Effects in 12-Bit Successive-Approximation Analog-To-Digital Converters

Analog-to-digital (A/D) converters are critical components in many space and military systems, and there have been numerous advances in A/D converter technology that have increased the resolution and conversion time. The increased performance is due to two factors: (1) advances in circuit design and complexity, which have increased the number of components and the integration density; and (2) new process technologies, such as BiCMOS, which provide better performance, cost, and smaller size in mixed-signal circuits. High-speed A/D converters, with conversion rates above 1 MHz, present a challenge to circuit designers and test engineers. Their complex architectures and high-performance specifications result in numerous possible failure modes when they are subjected to ionizing radiation. The dominant failure mode may depend on the specific application because the fundamental effects on MOS and bipolar transistors are strongly affected by bias conditions.

Lee, C. I.↗