Search NASA⌕ Search

SEARCH · Search NASA

Results for “Accelerator Control System”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,621 records · Page 90

Diagnostic Systems in the Muon $g-2$ experiment at Fermilab

The muon anomalous magnetic moment, $a_\mu=\frac{g-2}{2}$, is a low-energy observable which can be both measured and computed to high precision, making it a sensitive test of the Standard Model and a probe for new physics. This anomaly was measured with a precision of $0.20$~parts per million (ppm) by the Fermilab's Muon g-2 (E989) experiment. The final goal of the E989 experiment is to reach a precision of $0.14$~ppm. The experiment is based on the measurement of the muon spin anomalous precession frequency, $\omega_a$, based on the arrival time distribution of high-energy decay positrons observed by 24 electromagnetic calorimeters, placed around the inner circumference of a $14$~m diameter storage ring, and on the precise knowledge of the storage ring magnetic field and of the beam time and space distribution. Achieving this level of precision requires strict control over systematics, which is ensured through several diagnostic devices. At the accelerator level, these devices monitor the quality of the injected beam (e.g., verifying that it has the correct momentum), while at the detector level, they track both the magnetic field and the gain of the calorimeters. In this work the devices and techniques used by the E989 experiment will be presented.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Mechanism of Peptide Agonist Binding in CXCR4 Chemokine Receptor

Chemokine receptors are key G-protein-coupled receptors (GPCRs) that control cell migration in immune system responses, development of cardiovascular and central nervous systems, and numerous diseases. In particular, the CXCR4 chemokine receptor promotes metastasis, tumor growth and angiogenesis in cancers. CXCR4 is also used as one of the two co-receptors for T-tropic HIV-1 entry into host cells. Therefore, CXCR4 serves as an important therapeutic target for treating cancers and HIV infection. Apart from the CXCL12 endogenous peptide agonist, previous studies suggested that the first 17 amino acids of CXCL12 are sufficient to activate CXCR4. Two 17-residue peptides with positions 1–4 mutated to RSVM and ASLW functioned as super and partial agonists of CXCR4, respectively. However, the mechanism of peptide agonist binding in CXCR4 remains unclear. Here, we have investigated this mechanism through all-atom simulations using a novel Peptide Gaussian accelerated molecular dynamics (Pep-GaMD) method. The Pep-GaMD simulations have allowed us to explore representative binding conformations of each peptide and identify critical low-energy states of CXCR4 activated by the super versus partial peptide agonists. Our simulations have provided important mechanistic insights into peptide agonist binding in CXCR4, which are expected to facilitate rational design of new peptide modulators of CXCR4 and other chemokine receptors.

59 BASIC BIOLOGICAL SCIENCES↗

Intensified High-Dose Chemoradiotherapy With Induction Chemotherapy in Patients With Locally Advanced Non-Small-Cell Lung Cancer-Safety and Toxicity Results Within a Prospective Trial

Purpose: To analyze the toxicity profile of an intensified definitive chemoradiotherapy (CRT) schedule in patients with locally advanced non-small-cell lung cancer (Stage IIIA N2/selected IIIB) treated within a prospective multicenter trial. Patients and Methods: After mediastinoscopy and routine staging procedures, three cycles of induction chemotherapy (cisplatin 50 mg/m{sup 2}, Days 1 and 8; paclitaxel 175 mg/m{sup 2} Day 1, every 21 days) were planned, followed by concurrent CRT (accelerated-hyperfractionated regimen, 45 Gy, 2 x 1.5 Gy/d, cisplatin 50 mg/m{sup 2}, Days 64 and 71, vinorelbine 20 mg/m{sup 2}, Days 64 and 71). At 45 Gy, a multidisciplinary panel decision was made regarding operability. Inoperable patients received definitive radiotherapy (total dose 65 or 71 Gy, depending on the mean lung dose) with additional concurrent chemotherapy (cisplatin 40 mg/m{sup 2}, Day 85; vinorelbine 15 mg/m{sup 2}, Days 85 and 92). Results: A total of 28 patients (23 men and 5 women; median age, 58 years; range 41-73; Stage IIIA in 3 and Stage IIIB in 25) were judged ineligible for surgery by the multidisciplinary panel and underwent definitive CRT (75% of the patients received 71 Gy). The maximum toxicity (Grade 3 or greater) during induction chemotherapy included leukopenia (11%) and anemia (4%). During concurrent CRT, leukopenia (Grade 3 or greater) was observed in 39% of the patients. The maximal nonhematologic toxicity during concurrent CRT included esophagitis (Grade 3 or greater) in 18% and pneumonitis (Grade 3 or greater) in 4% of the patients. At 3 years, the locoregional control rate was 52% (95% confidence interval, 29-75%) and the overall survival rate was 31% (95% confidence interval, 12-50%). Conclusion: This intensified treatment protocol with induction chemotherapy and concurrent CRT, including hyperfractionated-accelerated RT, showed only moderate toxicity and proved feasible. This treatment represents the definitive CRT arm of our ongoing multicenter randomized trial comparing definitive CRT and trimodality treatment.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Revealing multiscale competing processes in the solid-state synthesis of single-crystalline layered oxide positive electrodes

Solid-state synthesis involves a web of coupled chemical reactions and physical changes that unfold across multiple scales. Efforts to fine-tune its parameters have historically followed heuristic, trial-driven workflows that demand significant time and resources. In this study, we aimed to open this black box by employing multiscale in situ synchrotron imaging and diffraction. Using LiNi 0.5 Mn 0.3 Co 0.2 O 2 battery positive electrode material as a model system and Ba-based sintering aids, we reveal dopant segregation, intergranular mass transport, and porosity evolution as key drivers of single-crystalline particle formation. Notably, we uncovered a dynamic competition between particle-level grain coalescence and atomic-scale cation disordering, both of which are thermally activated yet have opposing impacts on battery performance. These findings highlight the coupled, multiscale nature of structure development and offer a mechanistic basis for optimizing the solid-state synthesis process. This framework provides a path toward more controlled, efficient, and scalable production of high-performance battery positive electrode materials.

36 MATERIALS SCIENCE↗

Fast BPM data distribution for global orbit feedback using commercial gigabit ethernet technology

In order to correct beam perturbations in RHIC around 10Hz, a new fast data distribution network was required to deliver BPM position data at rates several orders of magnitude above the capability of the existing system. The urgency of the project limited the amount of custom hardware that could be developed, which dictated the use of as much commercially available equipment as possible. The selected architecture uses a custom hardware interface to the existing RHIC BPM electronics together with commercially available Gigabit Ethernet switches to distribute position data to devices located around the collider ring. Using the minimum Ethernet packet size and a field programmable gate array (FPGA) based state machine logic instead of a software based driver, real-time and deterministic data delivery is possible using Ethernet. The method of adapting this protocol for low latency data delivery, bench testing of Ethernet hardware, and the logic to construct Ethernet packets using FPGA hardware will be discussed. A robust communications system using almost all commercial off-the-shelf equipment was developed in under a year which enabled retrofitting of the existing RHIC BPM system to provide 10 KHz data delivery for a global orbit feedback scheme using 72 BPMs. Total latencies from data acquisition at the BPMs to delivery at the controller modules, including very long transmission distances, were kept under 100 {micro}s, which provide very little phase error in correcting the 10 Hz oscillations. Leveraging off of the speed of Gigabit Ethernet and wide availability of Ethernet products enabled this solution to be fully implemented in a much shorter time and at lower cost than if a similar network was developed using a proprietary method.

43 PARTICLE ACCELERATORS↗

Project DarkStar: Vision for LLNL in 2030

DarkStar was a Strategic Initiative (FY2021-FY2024) to investigate applications of Artificial Intelligence (AI) and Machine Learning (ML) to scientific problems of complex hydrodynamics, shockwave physics and energetic materials. The research focused on physics and engineering design as a process that can be tremendously accelerated through merging AI with advanced physics simulation on exascale-class platforms, and to experimentally validate this revolutionary new approach through dynamic materials campaigns. A central thread of scientific inquiry was in the application of AI to enable human understanding of how to control hydrodynamic instability (which has impacts to areas such as inertial confinement fusion) via engineering features and time-dependent sources. Motivated by an unfinished line of research started by Dr. Johnny von Neumann, AI-enabled simulation approaches were developed that allowed DarkStar researchers to uncover several ground-breaking discoveries regarding hydrodynamic instability, including how to completely suppress Richtmyer-Meshkov instability (RMI). These S&T discoveries, along with other advances, have shown the way for an entirely new approach to time-dependent problems known as inverse design – the idea that complex systems can be developed directly from a final state that is to be achieved and resolve the initial design via satisfying several constraints simultaneously via AI/ML. Through experimental campaigns conducted across a wide range of facilities in the NNSA complex (the High Explosive Application Facility at LLNL, the Dynamic Compression Sector/Advanced Photon Source at Argonne National Lab, and Special Technologies Laboratory at MSTS) the radical new AI/ML approach to engineering complex material dynamics was verified, establishing a new field of study within the realm of shock physics. As advanced manufacturing capabilities continue to develop, the great importance of inverse design as a means to apply that technology effectively for NNSA missions will feature prominently over this decade. DarkStar has positioned NNSA as a world-leader in this newly emerging cross-disciplinary area of AI methods for advanced physics simulation and pioneered multiple novel approaches that have enabled the broader scientific community. By allowing us to see past the horizon, to 2030 and beyond, DarkStar has illuminated the vast potential of AI/ML to impact a wide range of new national security missions and, consequently, multiple areas of further research have already emerged across the NNSA and DOD complex.

42 ENGINEERING↗

SU-E-T-593: Outcomes and Toxicities From a Clinical Trial of APBI Using MERT+IMRT with the Same XMLC

Purpose: We present the results from a clinical trial of accelerated partial breast irradiation (APBI), using mixed modulated photon and electron beams (MERT+IMRT) with the same photon multileaf collimator (xMLC). Methods: Seven patients were enrolled in the first year of the APBI clinical trial. Patients were selected following the conditions included in the NSABP B-39/RTOG 0413 protocol. The targets and clinically relevant normal structures were contoured on the CT images following this protocol for APBI-EBRT. All treatments were delivered using combined modulated electron and photon beams by means of the same xMLC installed in a SIEMENS Primus linac, with a reduced SSD equal to 60 cm for electron beams. The plans were performed with a treatment planning system based on full Monte Carlo simulations, called CARMEN, developed by our group. Simultaneously, an alternative IMRT plan was calculated with the commercial TPS PINNACLE v8.0m (Philips), and both plans were compared. An ad-hoc breast phantom with semi-spherical geometry called NAOMI was designed for a specific QA protocol. Patients received a total dose of 38.5 Gy, delivered in 10 fractions over 5 consecutive days, with a twice-a-day hypofractionated schema.Follow-up visits during 2.5 years on average were repeated at 1 month post-treatment, every 3 months for the first year, and every 6 months for the second year. Toxicity was scored according to National Cancer Institute Common Terminology Criteria for Adverse Events (CTCAE version 3.0). Results: This APBI technique achieved high loco-regional control rates and showed low acute toxicity (grade 1 of CTCAE) and no toxicities from first month onwards. Photographic assessment of cosmesis showed skin excellent results. Conclusion: The clinical results achieved with MERT+IMRT by using the same xMLC are comparable or even better than those obtained with other APBI techniques, thanks to a software solution without any additional equipment or specific device.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Beam characterization at NSRL for radiobiological experiments—phase 1

An experimental campaign was carried out at the NASA Space Radiation Laboratory to perform an additional, independent dosimetric characterization of the beams of protons, helium and carbon ions for radiobiological experiments. The campaign was undertaken by the request and with the support from the National Cancer Institute, U.S. In this initial phase, the goals were to obtain a first assessment of the dosimetric reproducibility of the beam control system, including analysis of spatial homogeneity and evaluation of ion beam contamination. They should facilitate the design of further experimental campaigns for beam characterization for radiobiological experiments. Measurements included reference dosimetry with comparison of in-house and external ionization chambers and electrometers, lateral-dose profile measurements in air, depth-dose profile in a water tank, evaluation of water equivalent thickness of a HDPE binary range shifter and estimation of impurities of the investigated helium-ion beam. The experiments and results are presented.

43 PARTICLE ACCELERATORS↗

Novel imaging techniques, integrated with mineralogical, geochemical and microbiological characterizations to determine the biogeochemical controls on technetium mobility in FRC sediments

The objective of this research program was to take a highly multidisciplinary approach to define the biogeochemical factors that control technetium (Tc) mobility in FRC sediments. The aim was to use batch and column studies to probe the biogeochemical conditions that control the mobility of Tc at the FRC. Background sediment samples from Area 2 (pH 6.5, low nitrate, low {sup 99}Tc) and Area 3 (pH 3.5, high nitrate, relatively high {sup 99}Tc) of the FRC were selected (http://www.esd.ornl.gov/nabirfrc). For the batch experiments, sediments were mixed with simulated groundwater, modeled on chemical constituents of FRC waters and supplemented with {sup 99}Tc(VII), both with and without added electron donor (acetate). The solubility of the Tc was monitored, alongside other biogeochemical markers (nitrate, nitrite, Fe(II), sulfate, acetate, pH, Eh) as the 'microcosms' aged. At key points, the microbial communities were also profiled using both cultivation-dependent and molecular techniques, and results correlated with the geochemical conditions in the sediments. The mineral phases present in the sediments were also characterized, and the solid phase associations of the Tc determined using sequential extraction and synchrotron techniques. In addition to the batch sediment experiments, where discrete microbial communities with the potential to reduce and precipitate {sup 99}Tc will be separated in time, we also developed column experiments where biogeochemical processes were spatially separated. Experiments were conducted both with and without amendments proposed to stimulate radionuclide immobilization (e.g. the addition of acetate as an electron donor for metal reduction), and were also planned with and without competing anions at high concentration (e.g. nitrate, with columns containing Area 3 sediments). When the columns had stabilized, as determined by chemical analysis of the effluents, we used a spike of the short-lived gamma emitter {sup 99m}Tc (50-200 MBq; half life 6 hours) and its mobility was monitored using a {gamma}-camera. Incorporation of low concentrations of the long-lived 99Tc gave a tracer that can be followed by scintillation counting, should the metastable form of the radionuclide decay to below detection limits before the end of the experiment (complete immobilization or loss of the Tc from the column). After the Tc was reduced and immobilized, or passed through the system, the columns were dismantled carefully in an anaerobic cabinet and the pore water geochemistry and mineralogy of the columns profiled. Microbial community analysis was determined, again using molecular and culture-dependent techniques. Experimental results were also modeled using an established coupled speciation and transport code, to develop a predictive tool for the mobility of Tc in FRC sediments. From this multidisciplinary approach, we hoped to obtain detailed information on the microorganisms that control the biogeochemical cycling of key elements at the FRC, and we would also be able to determine the key factors that control the mobility of Tc at environmentally relevant concentrations at this site.

43 PARTICLE ACCELERATORS↗

Three-dimensional anisotropic adaptive filtering of projection data for noise reduction in cone beam CT

Purpose: The combination of quickly rotating C-arm gantry with digital flat panel has enabled the acquisition of three-dimensional data (3D) in the interventional suite. However, image quality is still somewhat limited since the hardware has not been optimized for CT imaging. Adaptive anisotropic filtering has the ability to improve image quality by reducing the noise level and therewith the radiation dose without introducing noticeable blurring. By applying the filtering prior to 3D reconstruction, noise-induced streak artifacts are reduced as compared to processing in the image domain. Methods: 3D anisotropic adaptive filtering was used to process an ensemble of 2D x-ray views acquired along a circular trajectory around an object. After arranging the input data into a 3D space (2D projections + angle), the orientation of structures was estimated using a set of differently oriented filters. The resulting tensor representation of local orientation was utilized to control the anisotropic filtering. Low-pass filtering is applied only along structures to maintain high spatial frequency components perpendicular to these. The evaluation of the proposed algorithm includes numerical simulations, phantom experiments, and in-vivo data which were acquired using an AXIOM Artis dTA C-arm system (Siemens AG, Healthcare Sector, Forchheim, Germany). Spatial resolution and noise levels were compared with and without adaptive filtering. A human observer study was carried out to evaluate low-contrast detectability. Results: The adaptive anisotropic filtering algorithm was found to significantly improve low-contrast detectability by reducing the noise level by half (reduction of the standard deviation in certain areas from 74 to 30 HU). Virtually no degradation of high contrast spatial resolution was observed in the modulation transfer function (MTF) analysis. Although the algorithm is computationally intensive, hardware acceleration using Nvidia's CUDA Interface provided an 8.9-fold speed-up of the processing (from 1336 to 150 s). Conclusions: Adaptive anisotropic filtering has the potential to substantially improve image quality and/or reduce the radiation dose required for obtaining 3D image data using cone beam CT.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Flying focus: Spatial and temporal control of intensity for laser-based applications

An advanced focusing scheme, called a "flying focus," uses a chromatic focusing system combined with a broadband laser pulse with its colors arranged in time to propagate a high intensity focus over a distance that can be much greater than its Rayleigh length, while decoupling the speed at which the peak intensity propagates from its group velocity. The flying focus generates a short effective pulse duration with a small diameter focal spot that co- or counter-propagates along the optical axis at any velocity. Experiments validating the concept measured subluminal (–0.09c) to superluminal (39c) focal spot velocities with a nearly constant peak intensity over 4.5 mm. Experiments that increased the peak intensity above the ionization threshold for gas demonstrated ionization waves propagating at the velocity of the flying focus. Here these ionization waves of any velocity overcome several laser-plasma propagation issues, including ionization-induced refraction. The flying focus presents opportunities to overcome current fundamental limitations in laser-plasma amplifilers, laser wakefield accelerators, photon accelerators, and high-order frequency conversion.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Chemoradiation With Concomitant Boosts Followed by Radical Surgery in Locally Advanced Cervical Cancer: Long-term Results of the ROMA-2 Prospective Phase 2 Study

Purpose: This prospective, phase 2 study aimed at assessing the efficacy of accelerated fractionation radiation therapy by concomitant boosts (CBs) associated with chemoradiation therapy (CRT) of the whole pelvis, in improving the rate of pathological complete response (pCR) to treatment in patients with International Federation of Gynaecology and Obstetrics (FIGO) stage IB2-IVA locally advanced cervical cancer. Methods and Materials: Neoadjuvant CRT included conformal irradiation of the whole pelvis with a total dose of 39.6 Gy (1.8 cGy/fraction, 22 fractions), plus additional irradiation of primary tumor and parametria with 10.8 Gy administered with CBs (0.9 cGy/fraction, 12 fractions, every other day). Concomitant chemotherapy included cisplatin (20 mg/m{sup 2}, days 1-4 and 26-30 of treatment), and capecitabine (1300 mg/m{sup 2}/daily, orally) during the first 2 and the last 2 weeks of treatment. Radical hysterectomy plus pelvic with or without aortic lymphadenectomy was performed within 6 to 8 weeks from CRT. Toxicity was recorded according to Radiation Therapy Oncology Group toxicity criteria and Chassagne grading system. Based on the Simon design, 103 cases were required, and the regimen would be considered active if >45 pCR were registered (α error = 0.05; β error = 0.1). Results: pCR was documented in 51 cases (50.5%), and the regimen was considered active, according to the planned statistical assumptions. At median follow-up of 36 months (range: 7-85 months), the 3-year local failure rate was 7%, whereas the 3-year disease-free and overall survival rates were 73.0% and 86.1%, respectively. Grade 3 leukopenia and neutropenia were reported in only 1 and 2 cases, respectively. Gastrointestinal toxicity was always grade 1 or 2. Conclusions: Addition of CBs in the accelerated fractionation modality to the whole pelvis chemoradiation followed by radical surgery results in a high rate of pathologically assessed complete response to CRT and a very encouraging local control rate, with acceptable toxicity.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Nonlinear plasma experiments in geospace with gigawatts of RF power at HAARP

The ionosphere is the ionized uppermost layer of our atmosphere (from 70 – 500 km altitude) where free electron densities yield peak critical frequencies in the HF (3 – 30 MHz) range. The ionosphere thus provides a quiescent plasma target, stable on timescales of minutes, for a whole host of active plasma experiments. High power RF experiments on ionospheric plasma conducted in the U.S. have been reported since 1970. The largest HF transmitter built to date is the HAARP phased-array HF transmitter near Gakona, Alaska which can deliver up to 3.6 Gigawatts (ERP) of CW RF power in the range of 2.8 – 10 MHz to the ionosphere with microsecond pointing, power modulation, and frequency agility. With an ionospheric background thermal energy in the range of only 0.1 eV, this amount of power gives access to the highest regimes of the nonlinearity (RF intensity to thermal pressure) ratio. HAARP’s unique features have enabled the conduct of a number of unique nonlinear plasma experiments in the interaction region of overdense ionospheric plasma including generation of artificial aurorae, artificial ionization layers, VLF wave-particle interactions in the magnetosphere, parametric instabilities, stimulated electromagnetic emissions (SEE), strong Langmuir turbulence (SLT) and suprathermal electron acceleration. Diagnostics include the Modular UHF Ionospheric Radar (MUIR) sited at HAARP, the SuperDARN-Kodiak HF radar, spacecraft radio beacons, HF receivers to record stimulated electromagnetic emissions (SEE) and telescopes and cameras for optical emissions. We report on short timescale ponderomotive overshoot effects, artificial field-aligned irregularities (AFAI), the aspect angle dependence of the intensity of the HF-enhanced plasma line, and production of suprathermal electrons. One of the primary missions of HAARP, has been the generation of ELF (300 – 3000 Hz) and VLF (3 – 30 kHz) radio waves which are guided to global distances in the Earth-ionosphere waveguide. We review recent efforts to improve the efficiency of the generation ELF/VLF and develop alternative mechanisms that do not require a natural ionospheric current. Applications include the controlled study of ionospheric irregularities affecting spacecraft communication and navigation systems.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Parametric study of transport beam lines for electron beams accelerated by laser-plasma interaction

In the last decade, laser-plasma acceleration of high-energy electrons has attracted strong attention in different fields. Electrons with maximum energies in the GeV range can be laser-accelerated within a few cm using multi-hundreds terawatt (TW) lasers, yielding to very high beam currents at the source (electron bunches with up to tens-hundreds of pC in a few fs). While initially the challenge was to increase the maximum achievable electron energy, today strong effort is put in the control and usability of these laser-generated beams that still lack of some features in order to be used for applications where currently conventional, radio-frequency (RF) based, electron beam lines represent the most common and efficient solution. Several improvements have been suggested for this purpose, some of them acting directly on the plasma source, some using beam shaping tools located downstream. Concerning the latter, several studies have suggested the use of conventional accelerator magnetic devices (such as quadrupoles and solenoids) as an easy implementable solution when the laser-plasma accelerated beam requires optimization. In this paper, we report on a parametric study related to the transport of electron beams accelerated by laser-plasma interaction, using conventional accelerator elements and tools. We focus on both, high energy electron beams in the GeV range, as produced on petawatt (PW) class laser systems, and on lower energy electron beams in the hundreds of MeV range, as nowadays routinely obtained on commercially available multi-hundred TW laser systems. For both scenarios, our study allows understanding what are the crucial parameters that enable laser-plasma accelerators to compete with conventional ones and allow for a beam transport. We show that suitable working points require a tradeoff-combination between low beam divergence and narrow energy spread.

43 PARTICLE ACCELERATORS↗

Combining the synergistic control capabilities of modeling and experiments: Illustration of finding a minimum-time quantum objective

A common way to manipulate a quantum system, for example spins or artificial atoms, is to use properly tailored control pulses. In order to accomplish quantum information tasks before coherence is lost, it is crucial to implement the control in the shortest possible time. Here we report the near time-optimal preparation of a Bell state with fidelity higher than 99% in an NMR experiment, which is feasible by combining the synergistic capabilities of modeling and experiments operating in tandem. In this work, the pulses preparing the Bell state are found by experiments that are recursively assisted with a gradient-based optimization algorithm working with a model. Thus, we exploit the interplay between model-based numerical optimal design and experimental-based learning control. Utilizing the balanced synergism between the dual approaches, as dictated by the case specific capabilities of each approach, should have broad applications for accelerating the search for optimal quantum controls.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Poster — Thur Eve — 56: Design of Quality Assurance Methodology for VMAT system on Agility System equipped with CVDR

The aim of this study was to analyze the feasibility of designing comprehensive QA plans using iComCAT for Elekta machines equipped with Agility multileaf collimator and continuously variable dose rate. Test plans with varying MLC speed, gantry speed, and dose rate were created and delivered in a controlled manner. A strip test was designed with three 1 cm MLC positions and delivered using dynamic, StepNShoot and VMAT techniques. Plans were also designed to test error in MLC position with various gantry speeds and various MLC speeds. The delivery fluence was captured using the electronic portal-imaging device. Gantry speed was found to be within tolerance as per the Canadian standards. MLC positioning errors at higher MLC speed with gravity effects does add more than 2 mm discrepancy. More tests need to be performed to evaluate MLC performance using independent measurement systems. The treatment planning system with end-to-end testing necessary for commissioning was also investigated and found to have >95% passing rates within 3%/3mm gamma criteria. Future studies involve performing off-axis gantry starshot pattern and repeating the tests on three matched Elekta linear accelerators.

07 ISOTOPE AND RADIATION SOURCES↗

Communication-Constrained Expansion Planning for Resilient Distribution Systems

Distributed generation and remotely controlled switches have emerged as important technologies to improve the resiliency of distribution grids against extreme weather-related disturbances. Therefore it becomes important to study how best to place them on the grid in order to meet a resiliency criteria, while minimizing costs and capturing their dependencies on the associated communication systems that sustain their distributed operations. This paper introduces the Optimal Resilient Design Problem for Distribution and Communication Systems (ORDPDC) to address this need. The ORDPDC is formulated as a two-stage stochastic mixed-integer program that captures the physical laws of distribution systems, the communication connectivity of the smart grid components, and a set of scenarios that specifies which components are affected by potential disasters. The paper proposes an exact branch-and-price algorithm for the ORDPDC that features a strong lower bound and a variety of acceleration schemes to address degeneracy. The ORDPDC model and branch-and-price algorithm were evaluated on a variety of test cases with varying disaster intensities and network topologies. The results demonstrate the significant impact of the network topologies on the expansion plans and costs, as well as the computational benefits of the proposed approach.

97 MATHEMATICS AND COMPUTING↗

Design Considerations and Operational Features of the Collimators for the Fermilab Main Injector and Recycler

The Fermilab Main Injector system delivers 700 kW of 120 GeV Proton beam for neutrino experiments. Since 2013 this has been achieved using slip stacking accumulation in the Recycler with up to 12 batches from the Fermilab Booster per Main Injector Ramp Cycle. To control activation from beam loss, collimation systems in the Booster to Recycler transfer line, in the Recycler and in the Main Injector are employed. Residual radiation measurements around the ring with detailed studies at the collimators are required to maintain adequate loss control. We will review design considerations, operational parameters and activation results for more than ten years of operation. Simulations with MARS15 are used to explore the activation rates and the isotopic composition of the resulting activation.

43 PARTICLE ACCELERATORS↗