Search NASA⌕ Search

SEARCH · Search NASA

Results for “DEPTH”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,621 records · Page 90

Simulation of open quantum systems via low-depth convex unitary evolutions

Simulating physical systems on quantum devices is one of the most promising applications of quantum technology. Current quantum approaches to simulating open quantum systems are still practically challenging on NISQ-era devices, because they typically require ancilla qubits and extensive controlled sequences. In this work, we propose a hybrid quantum-classical approach for simulating a class of open system dynamics called random-unitary channels. These channels naturally decompose into a series of convex unitary evolutions, which can then be efficiently sampled and run as independent circuits. The method does not require deep ancilla frameworks and thus can be implemented with lower noise costs. We implement simulations of open quantum systems up to dozens of qubits and with large channel ranks. Published by the American Physical Society 2024

Peetz, Joseph (ORCID:0000000274458028)↗

Is your cold-stream working for you or against you? An in-depth look at temperature and sample motion.

It is normally assumed that a commercial gaseous nitrogen cold-stream provides a sample environment near 100 K and that the force of the cold-stream does not induce movement in the sample. As might be expected, the reality is much more complex. Here, an investigation of one cold-stream, starting with the temperature profile, is presented. Using silicon single crystals and flexible mounting loops, an approximate force/vibration profile of the cold-stream is obtained. Results indicate that the center of the temperature profile is offset from the position suggested by the manufacturer-supplied alignment tool and coincides with the area within the cold-stream that has the most consistent force profile. Tests indicate that this region is only about one-third of the width of the cold-stream nozzle opening. To verify that the results were relevant to protein crystallographic data collection, the impact of cold-stream position on the final data quality for lysozyme crystals was analyzed. On the basis of the observations it is recommended that users perform a temperature profile of their cold-streams to ensure proper alignment instead of relying only on the alignment tool for setup. In addition, suggestions are made on what users can look for in data processing to identify problems with loop movement and what users can do to minimize the impact of these problems on their experiments.

59 BASIC BIOLOGICAL SCIENCES↗

Depth-dependent atomic valence determination by synchrotron techniques

The properties of many materials can be strongly affected by the atomic valence of the contained individual elements, which may vary at surfaces and other interfaces. These variations can have a critical impact on material performance in applications. In this work, a non-destructive method for the determination of layer-by-layer atomic valence as a function of material thickness is presented for La 0.7 Sr 0.3 MnO 3 (LSMO) thin films. The method utilizes a combination of bulk- and surface-sensitive X-ray absorption spectroscopy (XAS) detection modes; here, the modes are fluorescence yield and surface-sensitive total electron yield. The weighted-average Mn atomic valence as measured from the two modes are simultaneously fitted using a model for the layer-by-layer variation of valence based on theoretical model Hamiltonian calculations. Using this model, the Mn valence profile in LSMO thin film is extracted and the valence within each layer is determined to within an uncertainty of a few percent. The approach presented here could be used to study the layer-dependent valence in other systems or extended to different properties of materials such as magnetism.

Hamiltonian calculations↗

In-Depth Optimization with the OpenACC-to-FPGA Framework on an Arria 10 FPGA

The reconfigurable computing paradigm that uses field programmable gate arrays (FPGAs) has received renewed interest in the high-performance computing field due to FPGAs' unique combination of performance and energy efficiency. However, difficulties in programming and optimizing FPGAs have prevented them from being widely accepted as general-purpose computing devices. In accelerator-based heterogeneous computing, portability across diverse heterogeneous devices is also an important issue, but the unique architectural features in FPGAs make this difficult to achieve. To address these issues, a directive-based, high-level FPGA programming and optimization framework was previously developed. In this work, developed optimizations were combined holistically using the directive-based approach to show that each individual benchmark requires a unique set of optimizations to maximize performance. The relationships between FPGA resource usages and runtime performance were also explored.

Lambert, Jacob↗

Design, Optimization, and In-Depth Understanding of Front and Rear Junction Screen-Printed Double-Side Passivated Contacts Solar Cells

In this work, detailed numerical modeling is performed for front junction (FJ) and rear junction (RJ) n-type Si solar cells with screen-printed double-side poly-Si based tunnel oxide passivated contacts (TOPCon). Fundamental understanding of both structures is crucial to explore factors that limit the efficiency potential of the two designs. By investigating several key parameters such as front poly sheet resistance and thickness, bulk material properties, and carrier transport in our simulation model, we determine and explain why RJ cells outperform FJ cells. Our findings reveal that FJ suffers from present technological limitations of p-poly based passivated contacts, namely, i) large recombination observed in textured p-TOPCon emitter and ii) low solid solubility and hole mobility in boron-doped poly-Si resulting in very high sheet resistance of front p-poly layers which must be made thin to reduce absorption losses. In contrast, RJ desensitized the cell efficiency to front sheet resistance allowing application of ultra-thin front n-poly layers and is therefore ideally suited for double-side TOPCon cells. Lastly, we have developed a roadmap for efficiency projections of commercial-type screen-printed RJ and FJ topologies reaching ~24% and >22.5% efficiencies respectively, quantifying and explaining the impact of technological innovations on the performance of each design.

14 SOLAR ENERGY↗

In‐depth comparative analysis of Illumina ® MiSeq run metrics: Development of a wet‐lab quality assessment tool

Abstract Whole genome sequencing of bacterial isolates has become a daily task in many laboratories, generating incredible amounts of data. However, data acquisition is not an end in itself; the goal is to acquire high‐quality data useful for understanding genetic relationships. Having a method that could rapidly determine which of the many available run metrics are the most important indicators of overall run quality and having a way to monitor these during a given sequencing run would be extremely helpful to this effect. Therefore, we compared various run metrics across 486 MiSeq runs, from five different machines. By performing a statistical analysis using principal components analysis and a K ‐means clustering algorithm of the metrics, we were able to validate metric comparisons among instruments, allowing for the development of a predictive algorithm, which permits one to observe whether a given MiSeq run has performed adequately. This algorithm is available in an Excel spreadsheet: that is, MiSeq Instrument & Run (In‐Run) Forecast. Our tool can help verify that the quantity/quality of the generated sequencing data consistently meets or exceeds recommended manufacturer expectations. Patterns of deviation from those expectations can be used to assess potential run problems and plan preventative maintenance, which can save valuable time and funding resources.

Kastanis, George John↗

Drought legacies are dependent on water table depth, wood anatomy and drought timing across the eastern US

Abstract Severe droughts can impart long‐lasting legacies on forest ecosystems through lagged effects that hinder tree recovery and suppress whole‐forest carbon uptake. However, the local climatic and edaphic factors that interact to affect drought legacies in temperate forests remain unknown. Here, we pair a dataset of 143 tree ring chronologies across the mesic forests of the eastern US with historical climate and local soil properties. We found legacy effects to be widespread, the magnitude of which increased markedly in diffuse porous species, sites with deep water tables, and in response to late‐season droughts (August–September). Using an ensemble of downscaled climate projections, we additionally show that our sites are projected to drastically increase in water deficit and drought frequency by the end of the century, potentially increasing the size of legacy effects by up to 65% and acting as a significant process shaping forest composition, carbon uptake and mortality.

Kannenberg, Steven A.↗

Compositional depth profiling of TaCN thin films

The composition profiling of thin TaCN films was studied. For the composition profile determination using x-ray photoemission spectrometry (XPS) in combination with Ar sputtering, preferential sputtering effects of N with respect to Ta and C were found to lead to inaccurate elemental concentrations. Sputter yield calculations for the given experimental conditions allowed for the correction of a part of the error, leading to fair accuracy by reference-free measurements. Further improvement of the accuracy was demonstrated by the calibration of the XPS compositions against elastic recoil detection analysis (ERDA) results. For Auger electron spectrometry (AES) in combination with Ar sputtering, accurate results required the calibration against ERDA. Both XPS and AES allowed for a reliable and accurate determination of the compositional profiles of TaCN-based thin films after calibration. Time-of-flight secondary-ion mass spectrometry was also used to assess the composition of the TaCN films. However, the analysis was hampered by large matrix effects due to small unintentional oxygen contents in the films. Energy-dispersive x-ray spectrometry is also discussed, and it is shown that an accurate reference-free measurement of the average film concentration can be achieved.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Systematic evaluation of four-dimensional hybrid depth scanning for carbon-ion lung therapy

Purpose: Irradiation of a moving target with a scanning beam requires a comprehensive understanding of organ motion as well as a robust dose error mitigation technique. The authors studied the effects of intrafractional respiratory motion for carbon-ion pencil beam scanning with phase-controlled rescanning on dose distributions for lung tumors. To address density variations, they used 4DCT data. Methods: Dose distributions for various rescanning methods, such as simple layer rescanning (LR), volumetric rescanning, and phase-controlled rescanning (PCR), were calculated for a lung phantom and a lung patient studies. To ensure realism, they set the scanning parameters such as scanning velocity and energy variation time to be similar to those used at our institution. Evaluation metrics were determined with regard to clinical relevance, and consisted of (i) phase-controlled rescanning, (ii) sweep direction, (iii) target motion (direction and amplitude), (iv) respiratory cycle, and (v) prescribed dose. Spot weight maps were calculated by using a beam field-specific target volume, which takes account of range variations for respective respiratory phases. To emphasize the impact of intrafractional motion on the dose distribution, respiratory gating was not used. The accumulated dose was calculated by applying a B-spline-based deformable image registration, and the results for phase-controlled layered rescanning (PCR{sub L}) and phase-controlled volumetric rescanning (PCR{sub V}) were compared. Results: For the phantom study, simple LR was unable to improve the dose distributions for an increased number of rescannings. The phase-controlled technique without rescanning (1 Multiplication-Sign PCR{sub L} and 1 Multiplication-Sign PCR{sub V}) degraded dose conformity significantly due to a reduced scan velocity. In contrast, 4 Multiplication-Sign PCR{sub L} or more significantly and consistently improved dose distribution. PCR{sub V} showed interference effects, but in general also improved dose homogeneity with higher numbers of rescannings. Dose distributions with single PCR{sub L}/PCR{sub V} with a sweep direction perpendicular to motion direction showed large hot/cold spots; however, this effect vanished with higher numbers of rescannings for both methods. Similar observations were obtained for the other dose metrics, such as target motion (SI/AP), amplitude (6-22 mm peak-to-peak) and respiratory period (3.0-5.0 s). For four or more rescannings, both methods showed significantly better results, albeit that volumetric PCR was more affected by interference effects, which lead to severe degradation of a few dose distributions. The clinical example showed the same tendencies as the phantom study. Dose assessment metrics (D95, Dmax/Dmin, homogeneity index) were improved with an increasing number of PCR{sub L}/PCR{sub V}, but with PCR{sub L} being more robust. Conclusions: PCR{sub L} requires a longer treatment time than PCR{sub V} for high numbers of rescannings in the NIRS scanning system but is more robust. Although four or more rescans provided good dose homogeneity and conformity, the authors prefer to use more rescannings for clinical cases to further minimize dose degradation effects due to organ motion.

60 APPLIED LIFE SCIENCES↗

Depth-resolved registration of transesophageal echo to x-ray fluoroscopy using an inverse geometry fluoroscopy system

Purpose: Image registration between standard x-ray fluoroscopy and transesophageal echocardiography (TEE) has recently been proposed. Scanning-beam digital x-ray (SBDX) is an inverse geometry fluoroscopy system designed for cardiac procedures. This study presents a method for 3D registration of SBDX and TEE images based on the tomosynthesis and 3D tracking capabilities of SBDX. Methods: The registration algorithm utilizes the stack of tomosynthetic planes produced by the SBDX system to estimate the physical 3D coordinates of salient key-points on the TEE probe. The key-points are used to arrive at an initial estimate of the probe pose, which is then refined using a 2D/3D registration method adapted for inverse geometry fluoroscopy. A phantom study was conducted to evaluate probe pose estimation accuracy relative to the ground truth, as defined by a set of coregistered fiducial markers. This experiment was conducted with varying probe poses and levels of signal difference-to-noise ratio (SDNR). Additional phantom and in vivo studies were performed to evaluate the correspondence of catheter tip positions in TEE and x-ray images following registration of the two modalities. Results: Target registration error (TRE) was used to characterize both pose estimation and registration accuracy. In the study of pose estimation accuracy, successful pose estimates (3D TRE < 5.0 mm) were obtained in 97% of cases when the SDNR was 5.9 or higher in seven out of eight poses. Under these conditions, 3D TRE was 2.32 ± 1.88 mm, and 2D (projection) TRE was 1.61 ± 1.36 mm. Probe localization error along the source-detector axis was 0.87 ± 1.31 mm. For the in vivo experiments, mean 3D TRE ranged from 2.6 to 4.6 mm and mean 2D TRE ranged from 1.1 to 1.6 mm. Anatomy extracted from the echo images appeared well aligned when projected onto the SBDX images. Conclusions: Full 6 DOF image registration between SBDX and TEE is feasible and accurate to within 5 mm. Future studies will focus on real-time implementation and application-specific analysis.

60 APPLIED LIFE SCIENCES↗